This document acknowledges the field of application for taps, shower outlets, shower sets and shower systems used in water supply systems with a pressure range of (0,05 to 1,0) MPa [(0,5 to 10) bar].
The tests described in this document are type tests (laboratory tests) and not quality control tests carried out during manufacture.
This document covers:
—   PN10 taps;
—   PN5 shower outlets;
—   PN5 shower sets;
—   PN10 shower systems.
The following products are excluded from this document:
—   shower taps on its own;
—   taps for filling bathtubs;
—   the tub filling function of combined taps;
—   the function of a tap that delivers e.g. boiling water or sparkling water, etc.;
—   body or side jet showers.
The conditions of use for taps and shower systems are given in Table 1. The conditions of use for showers sets and shower outlets are given in Table 2.
Table 1 — Conditions of use for taps and shower systems
Water supply system   Operating range of taps and shower systems
   Limits   Recommended
see Figure 1   dynamic pressure
≥ 0,05 MPa
(0,5 bar)
static pressure
≤ 1,0 MPa
(10,0 bar)   dynamic pressure b
(0,1 to 0,5) MPa
[(1,0 to 5,0) bar]
temperature   ≤ 70 °C a   ≤ 65 °C
a   This maximum temperature limit can only be reached for short durations not greater than 1 h.
b   Measured at the point of discharge.
NOTE   Taps and shower systems for use at pressures lower than those in Table 1 are not covered by this standard.
Table 2 — Conditions of use for shower outlets and shower sets
Water supply system   Operating range of showers
   Limits   Recommended
see Figure 1   dynamic pressure
≥ 0,05 MPa
(0,5 bar)
static pressure
≤ 0,5 MPa
(5,0 bar)   dynamic pressure
(0,1 to 0,3) MPa
[(1,0 to 3,0) bar]
temperature   ≤ 70 °C a   ≤ 42 °C
a   This maximum temperature limit can only be reached for short durations not greater than 1 h.
Key
1   cold water
2   hot water
3   mains supply pipe (supply pressures up to 10 bar)
4   water heater
Figure 1 — Supply system with a pressure range of (0,05 to 1,0) MPa [(0,5 to 10) bar]
Health and quality requirements in accordance to European and national legislation for final materials in contact with water intended for human consumption are not covered by this document.

  • Standard
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document acknowledges the field of application for taps, shower outlets, shower sets and shower systems used in water supply systems with a pressure range of (0,05 to 1,0) MPa [(0,5 to 10) bar].
The tests described in this document are type tests (laboratory tests) and not quality control tests carried out during manufacture.
This document covers:
—   PN10 taps;
—   PN5 shower outlets;
—   PN5 shower sets;
—   PN10 shower systems.
The following products are excluded from this document:
—   shower taps on its own;
—   taps for filling bathtubs;
—   the tub filling function of combined taps;
—   the function of a tap that delivers e.g. boiling water or sparkling water, etc.;
—   body or side jet showers.
The conditions of use for taps and shower systems are given in Table 1. The conditions of use for showers sets and shower outlets are given in Table 2.
Table 1 — Conditions of use for taps and shower systems
Water supply system   Operating range of taps and shower systems
   Limits   Recommended
see Figure 1   dynamic pressure
≥ 0,05 MPa
(0,5 bar)
static pressure
≤ 1,0 MPa
(10,0 bar)   dynamic pressure b
(0,1 to 0,5) MPa
[(1,0 to 5,0) bar]
temperature   ≤ 70 °C a   ≤ 65 °C
a   This maximum temperature limit can only be reached for short durations not greater than 1 h.
b   Measured at the point of discharge.
NOTE   Taps and shower systems for use at pressures lower than those in Table 1 are not covered by this standard.
Table 2 — Conditions of use for shower outlets and shower sets
Water supply system   Operating range of showers
   Limits   Recommended
see Figure 1   dynamic pressure
≥ 0,05 MPa
(0,5 bar)
static pressure
≤ 0,5 MPa
(5,0 bar)   dynamic pressure
(0,1 to 0,3) MPa
[(1,0 to 3,0) bar]
temperature   ≤ 70 °C a   ≤ 42 °C
a   This maximum temperature limit can only be reached for short durations not greater than 1 h.
Key
1   cold water
2   hot water
3   mains supply pipe (supply pressures up to 10 bar)
4   water heater
Figure 1 — Supply system with a pressure range of (0,05 to 1,0) MPa [(0,5 to 10) bar]
Health and quality requirements in accordance to European and national legislation for final materials in contact with water intended for human consumption are not covered by this document.

  • Standard
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   Scope of the EN 16905 series
This part of EN 16905 specifies the terms and definitions for the rating and performance calculation of gas-fired endothermic engine driven heat pumps for heating and/or cooling mode including the engine heat recovery, to be used outdoor.
This European Standard specifies the terms and definitions.
This European Standard is to be used in conjunction with the following standards:
a)   FprEN 16905-2:2022 on safety;
b)   EN 16905-3:2017 on test conditions;
c)   prEN 16905-4:2022 on the requirements, test conditions and test methods;
d)   FprEN 16905‐5:2022 on the calculation of seasonal performances in heating and cooling mode;
e)   the heat pump standards, EN 14511‐2, EN 14511-3 and EN 14825.
This European Standard only applies to appliances with a maximum heat input (based on net calorific value) not exceeding 70 kW at standard rating conditions.
This European Standard only applies to appliances under categories I2H, I2E, I2Er, I2R, I2E(S)B, I2L, I2LL, I2ELL, I2E(R)B, I2ESi, I2E(R), I3P, I3B, I3B/P, II2H3+, II2Er3+, II2H3B/P, II2L3B/P, II2E3B/P, II2ELL3B/P, II2L3P, II2H3P, II2E3P and II2Er3P according to EN 437.
This European Standard only applies to appliances having:
f)   gas fired endothermic engines under the control of fully automatic control systems;
g)   closed system refrigerant circuits in which the refrigerant does not come into direct contact with the fluid to be cooled or heated;
h)   where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 °C during normal operation;
i)   where the maximum operating pressure in the:
1)   heating water circuit (if installed) does not exceed 6 bar
2)   domestic hot water circuit (if installed) does not exceed 10 bar.
This European Standard applies to GEHP appliances only when used for space heating or space cooling or for refrigeration, with or without heat recovery.
This European Standard is applicable to GEHP appliances that are intended to be type tested. Requirements for GEHP appliances that are not type tested would need to be subject to further consideration.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   Scope of the EN 16905 series
This part of EN 16905 specifies the terms and definitions for the rating and performance calculation of gas-fired endothermic engine driven heat pumps for heating and/or cooling mode including the engine heat recovery, to be used outdoor.
This European Standard specifies the terms and definitions.
This European Standard is to be used in conjunction with the following standards:
a)   FprEN 16905-2:2022 on safety;
b)   EN 16905-3:2017 on test conditions;
c)   prEN 16905-4:2022 on the requirements, test conditions and test methods;
d)   FprEN 16905‐5:2022 on the calculation of seasonal performances in heating and cooling mode;
e)   the heat pump standards, EN 14511‐2, EN 14511-3 and EN 14825.
This European Standard only applies to appliances with a maximum heat input (based on net calorific value) not exceeding 70 kW at standard rating conditions.
This European Standard only applies to appliances under categories I2H, I2E, I2Er, I2R, I2E(S)B, I2L, I2LL, I2ELL, I2E(R)B, I2ESi, I2E(R), I3P, I3B, I3B/P, II2H3+, II2Er3+, II2H3B/P, II2L3B/P, II2E3B/P, II2ELL3B/P, II2L3P, II2H3P, II2E3P and II2Er3P according to EN 437.
This European Standard only applies to appliances having:
f)   gas fired endothermic engines under the control of fully automatic control systems;
g)   closed system refrigerant circuits in which the refrigerant does not come into direct contact with the fluid to be cooled or heated;
h)   where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 °C during normal operation;
i)   where the maximum operating pressure in the:
1)   heating water circuit (if installed) does not exceed 6 bar
2)   domestic hot water circuit (if installed) does not exceed 10 bar.
This European Standard applies to GEHP appliances only when used for space heating or space cooling or for refrigeration, with or without heat recovery.
This European Standard is applicable to GEHP appliances that are intended to be type tested. Requirements for GEHP appliances that are not type tested would need to be subject to further consideration.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60076-19-1:2023 defines the procedures that are applied to evaluate the uncertainty affecting the measurements of no-load and load losses during the routine tests on power transformers.
This document centres on measuring systems utilizing digital instruments, although the procedures can be adapted to evaluation of systems with analogue instruments where further uncertainty sources have to be taken into account.
This document specifies how to determine measurement uncertainty and how to apply corrections for known errors in the measurement chain. Information vis-à-vis judgement and traceability are given in IEC 60076-8:1997, 10.1 and 10.2.

  • Standard
    52 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60076-19-1:2023 defines the procedures that are applied to evaluate the uncertainty affecting the measurements of no-load and load losses during the routine tests on power transformers. This document centres on measuring systems utilizing digital instruments, although the procedures can be adapted to evaluation of systems with analogue instruments where further uncertainty sources have to be taken into account. This document specifies how to determine measurement uncertainty and how to apply corrections for known errors in the measurement chain. Information vis-à-vis judgement and traceability are given in IEC 60076-8:1997, 10.1 and 10.2.

  • Standard
    52 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 16905 specifies the calculation of the seasonal performance factor for gas-fired endothermic engine driven heat pumps for heating and/or cooling mode including the engine heat recovery, to be used outdoors.
This document only applies to appliances with a maximum heat input (based on net calorific value) not exceeding 70 kW at standard rating conditions.
This document only applies to appliances under categories I2H, I2E, I2Er, I2R, I2E(S)B, I2L, I2LL, I2ELL, I2E(R)B, I2ESi, I2E(R), I3P, I3B, I3B/P, II2H3+, II2Er3+, II2H3B/P, II2L3B/P, II2E3B/P, II2ELL3B/P, II2L3P, II2H3P, II2E3P and II2Er3P according to EN 437:2021.
This document only applies to appliances having:
a)   gas fired endothermic engines under the control of fully automatic control systems;
b)   closed system refrigerant circuits in which the refrigerant does not come into direct contact with the fluid to be cooled or heated;
c)   where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 °C during normal operation;
d)   where the maximum operating pressure in the:
1)   heating water circuit (if installed) does not exceed 6 bar,
2)   domestic hot water circuit (if installed) does not exceed 10 bar.
This document applies to GEHP appliances only when used for space heating or space cooling or for refrigeration, with or without heat recovery.
This document is applicable to GEHP appliances that are intended to be type tested. Requirements for GEHP appliances that are not type tested would need to be subject to further consideration.

  • Standard
    52 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to cookers for solid fuel (hand fired residential cookers).
The intended use of the appliances is cooking and space heating in residential buildings. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems.
These appliances can burn one or more types of the following solid fuels as specified:
-   wood logs;
-   compressed untreated wood;
-   wood pellets;
-   lignite briquettes;
-   solid mineral fuels;
-   peat briquettes.
This document is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fed.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of solid fuel burning cookers.

  • Standard
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to roomheaters for solid fuel (freestanding or inset solid fuel burning local space heating products that operate with fire doors either as closed only or as closed or open; insets without functional modification).
The intended use of the appliances is space heating in residential buildings. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems.
These appliances can burn one or more types of the following solid fuels as specified:
-   wood logs;
-   compressed untreated wood;
-   wood pellets;
-   lignite briquettes;
-   solid mineral fuels;
-   peat briquettes.
This document is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fed.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of solid fuel burning roomheaters.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to mechanical by wood pellets fed roomheaters, inset appliances and cookers up to 50 kW nominal heat output.
The intended use of the appliances is space heating in residential buildings and can be cooking. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems.
These appliances typically use auxiliary energy which is measured in this document as well. They can be operated with either natural draught or fan-assisted combustion air.
NOTE   A fan-assisted appliance does still operate under negative pressure in the flue gas system.
These appliances burn wood pellets only as specified. They only operate with the firedoors closed.
This document is not applicable to appliances:
-   with boiler intended for water systems having water temperatures above 110 °C and 3 bar;
-   with boiler intended for water systems having direct contact with sanitary hot water;
-   intended to be used with a pure horizontal exhaust (through the building wall);
-   with flue gas condensation in the appliance;
-   switching on/off for part load operation.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of mechanical by wood pellets fed roomheaters, inset appliances and cookers.

  • Standard
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to independent boiler appliances for solid fuel with a nominal output up to 50 kW (hand and automatically fired independent boilers (hereafter called appliances)).
The indented use of the appliances is space heating in residential buildings. This happens directly or via provision of hot water for central heating. They are designed for use only with open vented systems at a working pressure not exceeding 2 bar.
The appliances can burn one or more types of the following solid fuels as specified:
-   wood logs;
-   compressed untreated wood;
-   wood pellets;
-   lignite briquettes;
-   solid mineral fuels;
-   peat briquettes.
The appliances are operated closed and/or open.
The appliances are typed according to their tightness depending on their designation in accordance with a possible operation together with a room ventilation system.
This document is not applicable for:
-   appliances for hot water only production and heat output < 5 kW;
-   automatic stoking devices.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of solid fuel burning independent boiler appliances.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to inset appliances including open fires for solid fuel (hand fed solid fuel fired inset appliances, with or without functional modification, that operate without fire doors or operate with fire doors either as closed only or as closed or open, and also includes open fires fired by solid fuel).
The intended use of the appliances is space heating in residential buildings. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems.
The surround of these appliances is integrated with the building with the exception of free-standing appliances and those inset appliances which are installed into a fireplace recess or enclosure.
These appliances can burn one or more types of the following solid fuels as specified:
-   wood logs;
-   compressed untreated wood;
-   wood pellets;
-   lignite briquettes;
-   solid mineral fuels;
-   peat briquettes.
This document is also applicable to Kachelofen/Putzofen inset appliances, having nominal heat outputs up to 15 kW.
This document is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fed.
Open fireplace components such as a bottomgrate with associated fire front which are intended for installation into an existing heat resistant, insulated firebox are not covered by this document.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of solid fuel burning inset appliances including open fires.

  • Standard
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to independent boiler appliances for solid fuel with a nominal output up to 50 kW (hand and automatically fired independent boilers (hereafter called appliances)).
The indented use of the appliances is space heating in residential buildings. This happens directly or via provision of hot water for central heating. They are designed for use only with open vented systems at a working pressure not exceeding 2 bar.
The appliances can burn one or more types of the following solid fuels as specified:
-   wood logs;
-   compressed untreated wood;
-   wood pellets;
-   lignite briquettes;
-   solid mineral fuels;
-   peat briquettes.
The appliances are operated closed and/or open.
The appliances are typed according to their tightness depending on their designation in accordance with a possible operation together with a room ventilation system.
This document is not applicable for:
-   appliances for hot water only production and heat output < 5 kW;
-   automatic stoking devices.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of solid fuel burning independent boiler appliances.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to mechanical by wood pellets fed roomheaters, inset appliances and cookers up to 50 kW nominal heat output.
The intended use of the appliances is space heating in residential buildings and can be cooking. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems.
These appliances typically use auxiliary energy which is measured in this document as well. They can be operated with either natural draught or fan-assisted combustion air.
NOTE   A fan-assisted appliance does still operate under negative pressure in the flue gas system.
These appliances burn wood pellets only as specified. They only operate with the firedoors closed.
This document is not applicable to appliances:
-   with boiler intended for water systems having water temperatures above 110 °C and 3 bar;
-   with boiler intended for water systems having direct contact with sanitary hot water;
-   intended to be used with a pure horizontal exhaust (through the building wall);
-   with flue gas condensation in the appliance;
-   switching on/off for part load operation.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of mechanical by wood pellets fed roomheaters, inset appliances and cookers.

  • Standard
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to inset appliances including open fires for solid fuel (hand fed solid fuel fired inset appliances, with or without functional modification, that operate without fire doors or operate with fire doors either as closed only or as closed or open, and also includes open fires fired by solid fuel).
The intended use of the appliances is space heating in residential buildings. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems.
The surround of these appliances is integrated with the building with the exception of free-standing appliances and those inset appliances which are installed into a fireplace recess or enclosure.
These appliances can burn one or more types of the following solid fuels as specified:
-   wood logs;
-   compressed untreated wood;
-   wood pellets;
-   lignite briquettes;
-   solid mineral fuels;
-   peat briquettes.
This document is also applicable to Kachelofen/Putzofen inset appliances, having nominal heat outputs up to 15 kW.
This document is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fed.
Open fireplace components such as a bottomgrate with associated fire front which are intended for installation into an existing heat resistant, insulated firebox are not covered by this document.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of solid fuel burning inset appliances including open fires.

  • Standard
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to cookers for solid fuel (hand fired residential cookers).
The intended use of the appliances is cooking and space heating in residential buildings. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems.
These appliances can burn one or more types of the following solid fuels as specified:
-   wood logs;
-   compressed untreated wood;
-   wood pellets;
-   lignite briquettes;
-   solid mineral fuels;
-   peat briquettes.
This document is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fed.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of solid fuel burning cookers.

  • Standard
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to roomheaters for solid fuel (freestanding or inset solid fuel burning local space heating products that operate with fire doors either as closed only or as closed or open; insets without functional modification).
The intended use of the appliances is space heating in residential buildings. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems.
These appliances can burn one or more types of the following solid fuels as specified:
-   wood logs;
-   compressed untreated wood;
-   wood pellets;
-   lignite briquettes;
-   solid mineral fuels;
-   peat briquettes.
This document is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fed.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of solid fuel burning roomheaters.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 16905 specifies the calculation of the seasonal performance factor for gas-fired endothermic engine driven heat pumps for heating and/or cooling mode including the engine heat recovery, to be used outdoors.
This document only applies to appliances with a maximum heat input (based on net calorific value) not exceeding 70 kW at standard rating conditions.
This document only applies to appliances under categories I2H, I2E, I2Er, I2R, I2E(S)B, I2L, I2LL, I2ELL, I2E(R)B, I2ESi, I2E(R), I3P, I3B, I3B/P, II2H3+, II2Er3+, II2H3B/P, II2L3B/P, II2E3B/P, II2ELL3B/P, II2L3P, II2H3P, II2E3P and II2Er3P according to EN 437:2021.
This document only applies to appliances having:
a)   gas fired endothermic engines under the control of fully automatic control systems;
b)   closed system refrigerant circuits in which the refrigerant does not come into direct contact with the fluid to be cooled or heated;
c)   where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 °C during normal operation;
d)   where the maximum operating pressure in the:
1)   heating water circuit (if installed) does not exceed 6 bar,
2)   domestic hot water circuit (if installed) does not exceed 10 bar.
This document applies to GEHP appliances only when used for space heating or space cooling or for refrigeration, with or without heat recovery.
This document is applicable to GEHP appliances that are intended to be type tested. Requirements for GEHP appliances that are not type tested would need to be subject to further consideration.

  • Standard
    52 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard will fulfil requirements in Standardisation request M/543 by defining parameters and methods relevant for assessing the ability to repair and reuse products; the ability to upgrade products, excluding remanufacturing; the ability to access or remove certain components, consumables or assemblies from products to facilitate repair, reuse or upgrade and lastly by defining reusability indexes or criteria.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to gas-fired mCHP appliances producing domestic hot water and electricity. The electricity is generated in a process linked to the production of useful heat.
It applies to a mCHP appliances marketed as single unit or as a package fully specified by a manufacturer that have:
-   a gas heat input not exceeding 400 kW;
-   an electrical output not exceeding 50 kW;
-   a hot water storage capacity (if any) not exceeding 2 000 l.
EN 13203-1:2015 sets out in qualitative and quantitative terms the performance in delivery of domestic hot water for a variety of uses. It also gives a system for presenting the information to the user.
The present document sets out a method for assessing the energy performance of gas fired mCHP appliances. It defines several daily tapping cycles for each domestic hot water use, kitchen, shower, bath and a combination of these, together with corresponding test procedures, enabling the energy performances of different gas-fired appliances to be compared and matched to the needs of the user.
When the mCHP generator does not supply domestic hot water in the summer period, the present standard is not applicable. EN 13203-2:2022 is used for performance assessment of these generators.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard is applicable for measurements of the performance of dry vacuum cleaners for household use in or under conditions similar to those in households.
The purpose of this standard is to specify essential performance characteristics of dry vacuum cleaners being of interest to the users and to describe methods for measuring these characteristics.

  • Amendment
    87 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines product category rules (PCR) for electronic and electrical products and systems (EEPS).
It specifies the process and requirements on how to conduct life cycle assessment in the context of
environmental declarations.
PCR is complemented by additional product-specific rules (PSR), which further define e.g. functional units and
default scenarios in the product-specific context. Therefore, it also provides guidance on how to develop PSR
in corresponding technical committees.
This document provides common rules for:
a) life cycle assessment (LCA), including the requirements for developing default scenarios;
b) the LCA report;
c) the development of product specific rules.
This document provides further guidelines for environmental declarations.
The basic LCA principles and framework are based on the EN ISO 14040 series of standards (i.e EN ISO 14040
and ISO 14044), and therefore out of scope of the standard.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to gas-fired mCHP appliances producing domestic hot water and electricity. The electricity is generated in a process linked to the production of useful heat.
It applies to a mCHP appliances marketed as single unit or as a package fully specified by a manufacturer that have:
-   a gas heat input not exceeding 400 kW;
-   an electrical output not exceeding 50 kW;
-   a hot water storage capacity (if any) not exceeding 2 000 l.
EN 13203-1:2015 sets out in qualitative and quantitative terms the performance in delivery of domestic hot water for a variety of uses. It also gives a system for presenting the information to the user.
The present document sets out a method for assessing the energy performance of gas fired mCHP appliances. It defines several daily tapping cycles for each domestic hot water use, kitchen, shower, bath and a combination of these, together with corresponding test procedures, enabling the energy performances of different gas-fired appliances to be compared and matched to the needs of the user.
When the mCHP generator does not supply domestic hot water in the summer period, the present standard is not applicable. EN 13203-2:2022 is used for performance assessment of these generators.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the classification for commercial beverage coolers and their requirements and test methods. This document is applicable to integral refrigeration systems.
This document is not applicable to remote and secondary system cabinets.

  • Standard
    61 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard is applicable for measurements of the performance of dry vacuum cleaners for household use in or under conditions similar to those in households. The purpose of this standard is to specify essential performance characteristics of dry vacuum cleaners being of interest to the users and to describe methods for measuring these characteristics.

  • Amendment
    87 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies performance requirements (methods and procedures for testing and calculating) for determining the Minimum Efficiency Index (MEI) of rotodynamic glanded water pumps for pumping clean water, including where integrated in other products.
The pump types and sizes covered by this document are described in the Annex A. These pumps are designed and produced as duty pumps for pressures up to 16 bar for end suction pumps and up to 25 bar for multistage pumps, for all pumps designed for fluid temperatures between −10 °C and +120°C. Also covered are 4" (10,16 cm) and 6" (15,24 cm) submersible multistage pumps designed for fluid temperatures between 0 °C and 90 °C.

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document deals with the assessment of the proportion of re-used components in energy-related products on a generic level. All energy-related products are in the scope of this standard.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies classification criteria, test conditions and test procedures for performance testing of packaged refrigerating units for stationary cold room applications. This includes ductless units for cold storage applications at medium temperatures (MT) and low temperatures (LT) in either compact or split designs, fitted with electrically driven compressors, which work according to the vapour compression cycle.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2019-10-24 PeC: to revisit after SLR is published

  • Amendment
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

In accordance with standardisation request M/543 it is necessary to consider the "Documentation and/or marking regarding information relating to material efficiency of the product taking into account the intended audience (consumers, professionals or market surveillance authorities)". This standard facilitates by describing requirement for providing appropriate information.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

In accordance with standardisation request M/543 it is necessary to consider the "Use and recyclability of Critical Raw Materials to the EU, listed by the European Commission". This standard facilitates this requirement by describing appropriate information on critical materials.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2021: CLC legacy converted by DCLab NISOSTS

  • Amendment
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the classification for commercial beverage coolers and their requirements and test methods. This document is applicable to integral refrigeration systems.
This document is not applicable to remote and secondary system cabinets.

  • Standard
    61 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2021-03-29FM: CCMC decided not to offer for citation as linked to Directives that have been updated since this standard has been made available.
2021: CLC legacy converted by DCLab NISOSTS

  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the performance requirements for metal halide lamps for general lighting purposes. For some of the requirements given in this document, reference is made to "the relevant lamp data sheet". For some lamps, these data sheets are contained in this document. For other lamps, falling under the scope of this document, the relevant data are supplied by the lamp manufacturer or responsible vendor. The requirements of this document relate only to type testing. The requirements and tolerances specified in this document correspond to testing of a type test sample submitted by the manufacturer for that purpose. In principle this type test sample consists of units having characteristics typical of the manufacturer’s production and being as close to the production centre point values as possible. It can be expected that with the tolerances given in this document, the product manufactured in accordance with the type test sample will comply with this document for the majority of production. Due to the production spread however, it is inevitable that there will sometimes be products outside the specified tolerances. For guidance on sampling plans and procedures for inspection by attributes, see ISO 2859-10.

  • Amendment
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61167:2018 specifies the performance requirements for metal halide lamps for general lighting purposes. This fourth edition cancels and replaces the third edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition. a) A set of new lamp data sheets has been introduced for lamp types designed for replacing high pressure sodium lamps. b) A set of new lamp data sheets has been introduced for 4 200 K versions of 3 000 K lamp types already in the standard. c) A set of new lamp data sheets has been introduced for new lamp types where high frequency ignition data is important. d) Annex G has been revised to incorporate high frequency ignition. As a consequence of this change, all data sheets in the standard have been revised to a new format. e) A new informative Annex K has been introduced, giving recommended methods of making lamp temperature measurements.

  • Standard
    415 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies performance requirements (methods and procedures for testing and calculating) for determining the Minimum Efficiency Index (MEI) of rotodynamic glanded water pumps for pumping clean water, including where integrated in other products.
The pump types and sizes covered by this document are described in the Annex A. These pumps are designed and produced as duty pumps for pressures up to 16 bar for end suction pumps and up to 25 bar for multistage pumps, for all pumps designed for fluid temperatures between −10 °C and +120°C. Also covered are 4" (10,16 cm) and 6" (15,24 cm) submersible multistage pumps designed for fluid temperatures between 0 °C and 90 °C.

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies classification criteria, test conditions and test procedures for performance testing of packaged refrigerating units for stationary cold room applications. This includes ductless units for cold storage applications at medium temperatures (MT) and low temperatures (LT) in either compact or split designs, fitted with electrically driven compressors, which work according to the vapour compression cycle.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the classification for horizontal closed ice-cream freezer with access of the product from the top via transparent or solid lid(s) and specifies their requirements and test methods.
The ice-cream freezers defined in this document are different from supermarket segment freezers, as they work with static air cooling, with a skin evaporator (no evaporator fan) and are used specifically for the storage and display of pre-packed ice-cream.
This document is only applicable to integral type refrigeration systems. It is not applicable to remote and secondary system type cabinets. Ice-cream freezers defined in this document are intended to have a net volume ≤600 l. For transparent lid ice-cream freezers only, they are intended to have a net volume/TDA ≥ 0,35 m.

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the performance of clothes washing machines intended to be used by trained users e.g. in hotels, hospitals, factories, in light industry and on farms. It also covers washing machines declared for commercial use in public areas and operated by lay persons e.g. in launderettes, apartment houses and communal laundry rooms. The clothes washing machines can be utilizing cold and/or hot water supply and without heating or with heating devices for electricity, steam or gas. This European Standard covers top, front and side loaded clothes washing machines with horizontal or vertical axis and with one or more wash compartments. It also deals with appliances for both washing and drying textiles (washer-dryers) with respect to their washing related functions and to separate spin extractors related to their dewatering capabilities. NOTE 1 Performance of tumble dryers declared for commercial use is assessed in EN 50594. NOTE 2 The object is to state and define the principal performance characteristics of clothes washing machines declared for commercial use and to describe the test methods for measuring these characteristics. NOTE 3 This European Standard does not apply to continuous batch washing machines (e.g. tunnel washers) or washing machines only possible to operate with automatic loading and unloading. NOTE 4 This European Standard does not specify safety requirements for clothes washing machines declared for commercial use. Safety requirements are specified in EN 50571 and the EN ISO 10472- series.

  • Standard
    112 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard is applicable to tumble dryers intended to be used by trained users e.g. in hotels, hospitals, factories, in light industry and on farms. It covers tumble dryers declared for commercial use in public areas and operated by lay persons e.g. in launderettes, apartment houses and communal laundry rooms. This European Standard covers tumble dryers which use electricity, gas or steam as a heating source. The object is to state and define the principal performance characteristics of tumble dryers for commercial use of interest to users and to describe standard methods for measuring these characteristics. NOTE It does not apply to transfer tumble dryers or tumble dryers only possible to operate with automatic loading and unloading.

  • Standard
    65 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2016-01-19: If the vote is accepted update directive information in mother standard.
Common modifications intended for merge with PR=60123 & then transformed to homegrown AMD, as mother EN published as IEC identical
2021: CLC legacy converted by DCLab NISOSTS

  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62512:2012 provides a globally applicable and agreed method to test the washing and drying function of washer-dryers. Although this standard is based on IEC 61121:2012 on tumble dryers and IEC 60456:2010 on clothes washers, it specifies the conditions needed to test the combined function of washing and drying. The main elements of this standard are:   - the definition of the loads to be tested in continuous and interrupted operation cycles;  - the method for testing automatic and not automatic operation of the drying cycles;  - the way to handle the load for interrupted operation cycles;  - the correction to be applied to test results for continuous and interrupted operation cycles.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62512:2012 provides a globally applicable and agreed method to test the washing and drying function of washer-dryers. Although this standard is based on IEC 61121:2012 on tumble dryers and IEC 60456:2010 on clothes washers, it specifies the conditions needed to test the combined function of washing and drying. The main elements of this standard are:   - the definition of the loads to be tested in continuous and interrupted operation cycles;  - the method for testing automatic and not automatic operation of the drying cycles;  - the way to handle the load for interrupted operation cycles;  - the correction to be applied to test results for continuous and interrupted operation cycles.

  • Amendment
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Standardisation Request M/543 requires the following: "Definition of parameters and methods relevant for assessing durability, upgradability and ability to repair, re-use and re-manufacture of products". Hence, this Technical Report "Definitions related to material efficiency" will constitute a collection of common terms used in deliverables prepared in accordance with M/543. The purpose of such a collection is to provide a single definition of key terms used in different deliverables from the CEN-CENELEC TC10.
The source of the terms and definitions can be documents developed in the various working groups of the CEN-CENELEC TC10 or any text referenced by such documents.
In case of discrepancies between multiple definitions for the same term, this Technical report will recommend a preferred definition.

  • Technical report
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the classification for horizontal closed ice-cream freezer with access of the product from the top via transparent or solid lid(s) and specifies their requirements and test methods.
The ice-cream freezers defined in this document are different from supermarket segment freezers, as they work with static air cooling, with a skin evaporator (no evaporator fan) and are used specifically for the storage and display of pre-packed ice-cream.
This document is only applicable to integral type refrigeration systems. It is not applicable to remote and secondary system type cabinets. Ice-cream freezers defined in this document are intended to have a net volume ≤600 l. For transparent lid ice-cream freezers only, they are intended to have a net volume/TDA ≥ 0,35 m.