This European Standard covers multi-firing sauna stoves in which the heating stones are separated from and indirectly heated by the fire and the flue gases and which may be re-fuelled with several fuel loads.
This European Standard specifies requirements relating to the design, manufacture, construction, safety and performance (efficiency and emission) of multi-firing sauna stoves fired by wood logs and provides instructions for them. Furthermore, it also gives provisions for evaluation of conformity (i.e. initial type testing (ITT) and factory production control (FPC) and marking of these products.
This standard is applicable to hand-fuelled intermittent burning multi-firing sauna stoves, which provide heat into the space where they are installed.
These multi-firing sauna stoves may be supplied either as an assembled appliance or as a manufacturer’s pre-designed unit consisting of pre-fabricated components designed to be built on site in accordance with the manufacturer’s specified assembly instructions. One-off installations are not included.
These multi-firing sauna stoves may burn only natural wood logs in accordance with the appliance operating instructions.
Single-firing heat storage sauna stoves, in which the stones are directly heated by the fire and the flue gases, which pass through them, are not covered by this European Standard. This standard is also not applicable to mechanically fed sauna stoves, sauna stoves having fan assisted combustion air, sauna stoves fitted with a boiler, sauna stoves with incorporated flue or sauna stoves having any electrical connection.

  • Standard
    41 pages
    English language
    e-Library read for

This European Standard covers multi-firing sauna stoves in which the heating stones are separated from and indirectly heated by the fire and the flue gases and which may be re-fuelled with several fuel loads.
This European Standard specifies requirements relating to the design, manufacture, construction, safety and performance (efficiency and emission) of multi-firing sauna stoves fired by wood logs and provides instructions for them. Furthermore, it also gives provisions for evaluation of conformity (i.e. initial type testing (ITT) and factory production control (FPC) and marking of these products.
This standard is applicable to hand-fuelled intermittent burning multi-firing sauna stoves, which provide heat into the space where they are installed.
These multi-firing sauna stoves may be supplied either as an assembled appliance or as a manufacturer’s pre-designed unit consisting of pre-fabricated components designed to be built on site in accordance with the manufacturer’s specified assembly instructions. One-off installations are not included.
These multi-firing sauna stoves may burn only natural wood logs in accordance with the appliance operating instructions.
Single-firing heat storage sauna stoves, in which the stones are directly heated by the fire and the flue gases, which pass through them, are not covered by this European Standard. This standard is also not applicable to mechanically fed sauna stoves, sauna stoves having fan assisted combustion air, sauna stoves fitted with a boiler, sauna stoves with incorporated flue or sauna stoves having any electrical connection.

  • Standard
    41 pages
    English language
    e-Library read for

This document is applicable to residential solid fuel burning appliances of which the nominal space heat output is more than 6 % of the combined nominal space heat output and nominal water heat output (total heat output).
This document specifies requirements relating to the design, manufacture, construction, safety and performance (efficiency and emission) of appliances fired by solid fuel (hereafter referred to as “appliance(s)”) and provides instructions for them. Furthermore, it also gives provisions for the evaluation of conformity, i.e. initial type testing (ITT) and factory production control (FPC) and marking of these appliances.
This document specifies CO, NOx, OGC and particulate matter (PM) emission test methods.
This document is as well applicable to appliances intended to carry the load of a chimney.
Appliances receiving combustion air through ductwork from outside the external envelope, which is not air tight, are not considered roomsealed.
This document is not applicable to appliances with boiler parts in contact with fire or flue gases other than when the boiler parts are manufactured from steel or cast iron.
This document is not applicable to appliances with a boiler intended for water systems having:
-   water temperatures above 110 °C and/or an operating pressure of more than 300 kPa (3 bar);
-   direct contact with sanitary hot water.
This document is not applicable to appliances to be operated with ventilating systems which are intended to operate with pressure below -15 Pa in the room of installation of the appliance in relation to the outside atmosphere.

  • Standard
    164 pages
    English language
    e-Library read for

This document is applicable to inset appliances including open fires for solid fuel (hand fed solid fuel fired inset appliances, with or without functional modification, that operate without fire doors or operate with fire doors either as closed only or as closed or open, and also includes open fires fired by solid fuel).
The intended use of the appliances is space heating in residential buildings. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems.
The surround of these appliances is integrated with the building with the exception of free-standing appliances and those inset appliances which are installed into a fireplace recess or enclosure.
These appliances can burn one or more types of the following solid fuels as specified:
-   wood logs;
-   compressed untreated wood;
-   wood pellets;
-   lignite briquettes;
-   solid mineral fuels;
-   peat briquettes.
This document is also applicable to Kachelofen/Putzofen inset appliances, having nominal heat outputs up to 15 kW.
This document is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fed.
Open fireplace components such as a bottomgrate with associated fire front which are intended for installation into an existing heat resistant, insulated firebox are not covered by this document.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of solid fuel burning inset appliances including open fires.

  • Standard
    42 pages
    English language
    e-Library read for

This document is applicable to roomheaters for solid fuel (freestanding or inset solid fuel burning local space heating products that operate with fire doors either as closed only or as closed or open; insets without functional modification).
The intended use of the appliances is space heating in residential buildings. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems.
These appliances can burn one or more types of the following solid fuels as specified:
-   wood logs;
-   compressed untreated wood;
-   wood pellets;
-   lignite briquettes;
-   solid mineral fuels;
-   peat briquettes.
This document is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fed.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of solid fuel burning roomheaters.

  • Standard
    29 pages
    English language
    e-Library read for

This document is applicable to cookers for solid fuel (hand fired residential cookers).
The intended use of the appliances is cooking and space heating in residential buildings. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems.
These appliances can burn one or more types of the following solid fuels as specified:
-   wood logs;
-   compressed untreated wood;
-   wood pellets;
-   lignite briquettes;
-   solid mineral fuels;
-   peat briquettes.
This document is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fed.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of solid fuel burning cookers.

  • Standard
    41 pages
    English language
    e-Library read for

This document is applicable to independent boiler appliances for solid fuel with a nominal output up to 50 kW (hand and automatically fired independent boilers (hereafter called appliances)).
The indented use of the appliances is space heating in residential buildings. This happens directly or via provision of hot water for central heating. They are designed for use only with open vented systems at a working pressure not exceeding 2 bar.
The appliances can burn one or more types of the following solid fuels as specified:
-   wood logs;
-   compressed untreated wood;
-   wood pellets;
-   lignite briquettes;
-   solid mineral fuels;
-   peat briquettes.
The appliances are operated closed and/or open.
The appliances are typed according to their tightness depending on their designation in accordance with a possible operation together with a room ventilation system.
This document is not applicable for:
-   appliances for hot water only production and heat output < 5 kW;
-   automatic stoking devices.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of solid fuel burning independent boiler appliances.

  • Standard
    33 pages
    English language
    e-Library read for

This document is applicable to mechanical by wood pellets fed roomheaters, inset appliances and cookers up to 50 kW nominal heat output.
The intended use of the appliances is space heating in residential buildings and can be cooking. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems.
These appliances typically use auxiliary energy which is measured in this document as well. They can be operated with either natural draught or fan-assisted combustion air.
NOTE   A fan-assisted appliance does still operate under negative pressure in the flue gas system.
These appliances burn wood pellets only as specified. They only operate with the firedoors closed.
This document is not applicable to appliances:
-   with boiler intended for water systems having water temperatures above 110 °C and 3 bar;
-   with boiler intended for water systems having direct contact with sanitary hot water;
-   intended to be used with a pure horizontal exhaust (through the building wall);
-   with flue gas condensation in the appliance;
-   switching on/off for part load operation.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of mechanical by wood pellets fed roomheaters, inset appliances and cookers.

  • Standard
    42 pages
    English language
    e-Library read for

This document is applicable to mechanical by wood pellets fed roomheaters, inset appliances and cookers up to 50 kW nominal heat output.
The intended use of the appliances is space heating in residential buildings and can be cooking. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems.
These appliances typically use auxiliary energy which is measured in this document as well. They can be operated with either natural draught or fan-assisted combustion air.
NOTE   A fan-assisted appliance does still operate under negative pressure in the flue gas system.
These appliances burn wood pellets only as specified. They only operate with the firedoors closed.
This document is not applicable to appliances:
-   with boiler intended for water systems having water temperatures above 110 °C and 3 bar;
-   with boiler intended for water systems having direct contact with sanitary hot water;
-   intended to be used with a pure horizontal exhaust (through the building wall);
-   with flue gas condensation in the appliance;
-   switching on/off for part load operation.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of mechanical by wood pellets fed roomheaters, inset appliances and cookers.

  • Standard
    42 pages
    English language
    e-Library read for

This document is applicable to independent boiler appliances for solid fuel with a nominal output up to 50 kW (hand and automatically fired independent boilers (hereafter called appliances)).
The indented use of the appliances is space heating in residential buildings. This happens directly or via provision of hot water for central heating. They are designed for use only with open vented systems at a working pressure not exceeding 2 bar.
The appliances can burn one or more types of the following solid fuels as specified:
-   wood logs;
-   compressed untreated wood;
-   wood pellets;
-   lignite briquettes;
-   solid mineral fuels;
-   peat briquettes.
The appliances are operated closed and/or open.
The appliances are typed according to their tightness depending on their designation in accordance with a possible operation together with a room ventilation system.
This document is not applicable for:
-   appliances for hot water only production and heat output < 5 kW;
-   automatic stoking devices.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of solid fuel burning independent boiler appliances.

  • Standard
    33 pages
    English language
    e-Library read for

This document is applicable to cookers for solid fuel (hand fired residential cookers).
The intended use of the appliances is cooking and space heating in residential buildings. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems.
These appliances can burn one or more types of the following solid fuels as specified:
-   wood logs;
-   compressed untreated wood;
-   wood pellets;
-   lignite briquettes;
-   solid mineral fuels;
-   peat briquettes.
This document is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fed.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of solid fuel burning cookers.

  • Standard
    41 pages
    English language
    e-Library read for

This document is applicable to roomheaters for solid fuel (freestanding or inset solid fuel burning local space heating products that operate with fire doors either as closed only or as closed or open; insets without functional modification).
The intended use of the appliances is space heating in residential buildings. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems.
These appliances can burn one or more types of the following solid fuels as specified:
-   wood logs;
-   compressed untreated wood;
-   wood pellets;
-   lignite briquettes;
-   solid mineral fuels;
-   peat briquettes.
This document is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fed.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of solid fuel burning roomheaters.

  • Standard
    29 pages
    English language
    e-Library read for

This document is applicable to inset appliances including open fires for solid fuel (hand fed solid fuel fired inset appliances, with or without functional modification, that operate without fire doors or operate with fire doors either as closed only or as closed or open, and also includes open fires fired by solid fuel).
The intended use of the appliances is space heating in residential buildings. They can be fitted with a boiler (integral part of the appliance containing water to be heated up) for the supply of hot water for central heating systems.
The surround of these appliances is integrated with the building with the exception of free-standing appliances and those inset appliances which are installed into a fireplace recess or enclosure.
These appliances can burn one or more types of the following solid fuels as specified:
-   wood logs;
-   compressed untreated wood;
-   wood pellets;
-   lignite briquettes;
-   solid mineral fuels;
-   peat briquettes.
This document is also applicable to Kachelofen/Putzofen inset appliances, having nominal heat outputs up to 15 kW.
This document is not applicable to appliances with fan assisted combustion air or appliances that are mechanically fed.
Open fireplace components such as a bottomgrate with associated fire front which are intended for installation into an existing heat resistant, insulated firebox are not covered by this document.
This document specifies procedures for assessment and verification of constancy of performance (AVCP) of characteristics of solid fuel burning inset appliances including open fires.

  • Standard
    42 pages
    English language
    e-Library read for

This document is applicable to residential solid fuel burning appliances of which the nominal space heat output is more than 6 % of the combined nominal space heat output and nominal water heat output (total heat output).
This document specifies requirements relating to the design, manufacture, construction, safety and performance (efficiency and emission) of appliances fired by solid fuel (hereafter referred to as “appliance(s)”) and provides instructions for them. Furthermore, it also gives provisions for the evaluation of conformity, i.e. initial type testing (ITT) and factory production control (FPC) and marking of these appliances.
This document specifies CO, NOx, OGC and particulate matter (PM) emission test methods.
This document is as well applicable to appliances intended to carry the load of a chimney.
Appliances receiving combustion air through ductwork from outside the external envelope, which is not air tight, are not considered roomsealed.
This document is not applicable to appliances with boiler parts in contact with fire or flue gases other than when the boiler parts are manufactured from steel or cast iron.
This document is not applicable to appliances with a boiler intended for water systems having:
-   water temperatures above 110 °C and/or an operating pressure of more than 300 kPa (3 bar);
-   direct contact with sanitary hot water.
This document is not applicable to appliances to be operated with ventilating systems which are intended to operate with pressure below -15 Pa in the room of installation of the appliance in relation to the outside atmosphere.

  • Standard
    164 pages
    English language
    e-Library read for

This document is applicable to all types of fluid heating solar collectors. This document specifies performance requirements for fluid heating solar collectors with respect to durability, reliability, safety and thermal performance.
This document deals with the solar collector and not with assemblies. This document is not applicable to those devices in which a thermal storage unit is an integral part to such an extent that the collection process cannot be separated from the storage process for making the collector thermal performance measurements.

  • Standard
    24 pages
    English language
    e-Library read for

This document is applicable to all types of fluid heating solar collectors. This document specifies performance requirements for fluid heating solar collectors with respect to durability, reliability, safety and thermal performance.
This document deals with the solar collector and not with assemblies. This document is not applicable to those devices in which a thermal storage unit is an integral part to such an extent that the collection process cannot be separated from the storage process for making the collector thermal performance measurements.

  • Standard
    24 pages
    English language
    e-Library read for

This European Standard defines technical specifications and requirements of free hanging prefabricated ceil-ing mounted radiant panels with an air gap between construction and the emitter (not embedded) fed with water at temperatures below 120 °C connected with a centralized heating supply source intended to be in-stalled in buildings.
The panels should be installed with an upper insulation.
The European Standard does not apply to independent heating devices.
The European Standard also defines the additional common data that the manufacturer has to provide to the trade in order to ensure the correct application of the products.
This European standard does not cover the performance of hanging accessories.

  • Standard
    32 pages
    English language
    e-Library read for

This European Standard defines technical specifications and requirements of free hanging prefabricated ceil-ing mounted radiant panels with an air gap between construction and the emitter (not embedded) fed with water at temperatures below 120 °C connected with a centralized heating supply source intended to be in-stalled in buildings.
The panels should be installed with an upper insulation.
The European Standard does not apply to independent heating devices.
The European Standard also defines the additional common data that the manufacturer has to provide to the trade in order to ensure the correct application of the products.
This European standard does not cover the performance of hanging accessories.

  • Standard
    32 pages
    English language
    e-Library read for

This European Standard defines the technical specifications and requirements of radiators and convectors to be installed in heating systems in buildings including assessment and verification of constancy of performance.
This European Standard deals with radiators and convectors installed in a permanent manner in construction works, fed with water or steam at temperatures below 120 °C, supplied by a remote energy source.
This European Standard does not apply to independent heating appliances.
This European Standard also defines the additional common data that the manufacturer shall provide with the product in order to ensure the correct application of the products.

  • Standard
    38 pages
    English language
    e-Library read for

This European Standard defines procedures for determining the standard thermal outputs and other characteristics of radiators and convectors installed in a permanent manner in construction works, fed with water or steam at temperatures below 120 °C, supplied by a remote energy source.
This European Standard specifies the laboratory arrangements and testing methods to be adopted, the admissible tolerances, the criteria for selecting the samples to be tested and for verifying the conformity of the current production with the samples tested at the initial test.
This European Standard also defines the additional common data that the manufacturer shall provide with the product in order to ensure the correct application of the products.
This European Standard does not apply to fan assisted radiators, fan assisted convectors and trench convectors and to independent heating appliances.

  • Standard
    78 pages
    English language
    e-Library read for

This European Standard defines procedures for determining the standard thermal outputs and other characteristics of radiators and convectors installed in a permanent manner in construction works, fed with water or steam at temperatures below 120 °C, supplied by a remote energy source.
This European Standard specifies the laboratory arrangements and testing methods to be adopted, the admissible tolerances, the criteria for selecting the samples to be tested and for verifying the conformity of the current production with the samples tested at the initial test.
This European Standard also defines the additional common data that the manufacturer shall provide with the product in order to ensure the correct application of the products.
This European Standard does not apply to fan assisted radiators, fan assisted convectors and trench convectors and to independent heating appliances.

  • Standard
    78 pages
    English language
    e-Library read for

This European Standard defines the technical specifications and requirements of radiators and convectors to be installed in heating systems in buildings including assessment and verification of constancy of performance.
This European Standard deals with radiators and convectors installed in a permanent manner in construction works, fed with water or steam at temperatures below 120 °C, supplied by a remote energy source.
This European Standard does not apply to independent heating appliances.
This European Standard also defines the additional common data that the manufacturer shall provide with the product in order to ensure the correct application of the products.

  • Standard
    38 pages
    English language
    e-Library read for

This European Standard is applicable to residential solid fuel burning appliances.
This European Standard specifies requirements relating to the design, manufacture, construction, safety and performance (efficiency and emission) of appliances fired by solid fuel (hereafter referred to as appliance(s)) and provides instructions for them. Furthermore, it also gives provisions for the evaluation of conformity i.e. initial type testing (ITT) and factory production control (FPC) and marking of these appliances.
This European Standard also covers CO, NOx, OGC and particulate matter (PM / PME - see Annex F) emission test methods, however this European Standard does not contain any values for the limit on these emissions.
Appliances receiving combustion air through ductwork from outside the external envelope, which is not air tight, are not considered roomsealed.This European Standard is not applicable to appliances with boiler parts in contact with fire or flue gases other than when the boiler parts are manufactured from steel or cast iron.
This European Standard is not applicable to appliances with a boiler intended for water systems having
-   water temperatures above 110 °C and/or an operating pressure of more than 3 bar;
-   direct contact with sanitary hot water.
This European Standard does not cover appliances to be operated with ventilating systems which are intended to operate with pressure below - 15 Pa in the room of installation of the appliance in relation to the outside atmosphere.
This European Standard does not cover appliances intended to carry the load of a chimney.

  • Standard
    151 pages
    English language
    e-Library read for

This European Standard covers multi-firing sauna stoves in which the heating stones are separated from and indirectly heated by the fire and the flue gases and which may be re-fuelled with several fuel loads.
This European Standard specifies requirements relating to the design, manufacture, construction, safety and performance (efficiency and emission) of multi-firing sauna stoves fired by wood logs and provides instructions for them. Furthermore, it also gives provisions for evaluation of conformity (i.e. initial type testing (ITT) and factory production control (FPC) and marking of these products.
This standard is applicable to hand-fuelled intermittent burning multi-firing sauna stoves, which provide heat into the space where they are installed.
These multi-firing sauna stoves may be supplied either as an assembled appliance or as a manufacturer’s pre-designed unit consisting of pre-fabricated components designed to be built on site in accordance with the manufacturer’s specified assembly instructions. One-off installations are not included.
These multi-firing sauna stoves may burn only natural wood logs in accordance with the appliance operating instructions.
Single-firing heat storage sauna stoves, in which the stones are directly heated by the fire and the flue gases, which pass through them, are not covered by this European Standard. This standard is also not applicable to mechanically fed sauna stoves, sauna stoves having fan assisted combustion air, sauna stoves fitted with a boiler, sauna stoves with incorporated flue or sauna stoves having any electrical connection.

  • Standard
    55 pages
    English language
    e-Library read for

TC - Addition of NOTE in 6.3.2

  • Corrigendum
    2 pages
    English, French and German language
    e-Library read for

TC - Addition of NOTE in 6.2

  • Corrigendum
    2 pages
    English, French and German language
    e-Library read for

TC - Addition of NOTE in 6.3

  • Corrigendum
    2 pages
    English, French and German language
    e-Library read for

EN 1/prA1 covers all points to fulfil the requirements of mandate M/129 under the CPD given from the EC to CEN.

  • Amendment
    29 pages
    English language
    e-Library read for

This European Standard specifies requirements relating to the design, manufacture, construction, safety and performance (efficiency and emission) instructions and marking together with associated test methods and test fuels for type testing residential slow heat release appliances fired by solid fuel.
This European Standard is applicable to hand fuelled intermittent burning slow heat release appliances having thermal storage capacity such that they can provide heat for a declared period of time after the fire has gone out. This European Standard also specifies a minimum time period from the appliance achieving the maximum differential surface temperature and falling to 50 % of that maximum value. These appliances provide heat into the space where they are installed.
These slow heat release appliances may be supplied either as an assembled appliance or as a manufacturer’s pre-designed unit consisting of pre-fabricated components designed to be built on site in accordance with the manufacturer’s specified assembly instructions. One off installations are not included.
These appliances may burn either solid mineral fuels, peat briquettes, natural or manufactured wood logs or be multi-fuel in accordance with the appliance manufacturer’s instructions. Wood pellets which are hand fuelled may also be burned either on the existing appliance bottomgrate or in a special basket arrangement which is placed by the user into the existing firebox.
This European Standard is not applicable to mechanically fed appliances, appliances having fan assisted combustion air or appliances with boiler.

  • Standard
    63 pages
    English language
    e-Library read for

TC - Modification to A.6.2.1.1

  • Corrigendum
    3 pages
    English, French and German language
    e-Library read for

TC - Modification to A.6.2.1.1

  • Corrigendum
    3 pages
    English, French and German language
    e-Library read for

TC - Modification to A.6.2.1.2, Equation 4

  • Corrigendum
    3 pages
    English, French and German language
    e-Library read for

This European Standard specifies requirements relating to the design, manufacture, construction, safety and performance (efficiency and emissions), instructions and marking together with associated test methods and test fuels for type-testing residential space heaters fired by wood pellets, and mechanically fed up to 50 kW nominal heat output.
These appliances may be freestanding or inset appliances and provide heat into the space where they are installed and may be operated with either natural draught or fan-assisted combustion air. Additionally, where fitted with a boiler, they also provide domestic hot water and/or central heating. These appliances burn wood pellets only, in accordance with the appliance manufacturer's instructions. They operate with firedoors closed only.
Non mechanically fed appliances burning solid mineral fuels, peat briquettes and natural or manufactured wood logs are not included in this European Standard, but are covered by EN 13229 and EN 13240.
NOTE   These appliances may have an integral fuel hopper or be combined with an external fuel hopper.

  • Standard
    72 pages
    English language
    e-Library read for

This Standard is applicable to hand fired appliances whose primary function is to provide heat into the space in which they are installed and which are listed under categories 1b, 1c, 2b, 2c, 3a, 3b and 3c of table 1 of prEN 13229. Additionally, where fitted with a boiler, they also provide domestic hot water and/or central heating. These appliances may burn naturally occurring or manufactured solid mineral fuels, peat briquettes, natural or manufactured wood logs and biomass based products which are in the form of an identifiable consistent product or be multi-fuel in accordance with the appliance manufacturer's instructions. The surround of the appliance is integrated with the building with the exception of free-standing appliances and inset appliances which are installed into a fireplace recess or enclosure. This standard is not applicable to appliances having fan assisted combustion air. Open fireplace components such as a bottomgrate with associated firefront which the manufacturer supplied for installation inti an existing heat resistant, insulated firebox are not covered by this standard.

  • Amendment
    23 pages
    English language
    e-Library read for
  • Amendment
    23 pages
    German language
    e-Library read for

This Standard is applicable to hand fired appliances whose primary function is to cook and whose secondary function is to provide heat into the space in which they are installed. Additionally, where fitted with a boiler, they also provide domestic hot water and/or central heating. These appliances may burn naturally occuring or manufactured solid mineral fuels, peat briquettes, natural or manufactured wood logs and biomass based products which are in the form of an identifiable consistent products or be multi-fuel in accordance with the appliance maufacturer's instructions. This standard is not applicable to hopper fed or mechanically fired appliances or those appliances having fan assisted combustion air.

  • Amendment
    22 pages
    English language
    e-Library read for
  • Amendment
    22 pages
    German language
    e-Library read for

This Standard is applicable to non-mechanically fired appliances whose primary function is to provide heat into the space in which they are installed and which are listed under categories 1a and 2a of table 1 of prEN 13240. Additionally, where fitted with a boiler, they also provide domestic hot water and/or central heating. These appliances may burn naturally occurring or manufactured solid mineral fuels, peat briquettes, natural or manufactured wood logs and biomass based products which are in the form of an identifiable consistent product or be multi-fuel in accordance with the appliance manufacturer's instructions. This standard is not applicable to appliances having fan assisted combustion air.

  • Amendment
    23 pages
    English language
    e-Library read for

The standard is applicable to hand and automatically fired appliances having nominal heat outputs up to 50 kW, the primary function of which is to provide hot water for central heating and/or domestic use, and which are designed for use only with open vented systems at a working pressure not exceeding 2 bar. In addition to their primary function of providing hot water these appliances also provide space heating to the place of installation. These appliances may burn naturally occurring or manufactured solid mineral fuels, peat briquettes, natural or manufactured wood logs and biomass based products which are in the form of an identifiable consistent product or be multi-fuel in accordance with the appliance manufacturer's instructions.

  • Amendment
    20 pages
    English language
    e-Library read for
  • Amendment
    22 pages
    German language
    e-Library read for

This European Standard specifies the procedures for evaluating the conformity of radiators/convectors to EN 442-1. It specifies the procedures and methods for the initial evaluation and the controls required to maintain conformity.

  • Standard
    8 pages
    English language
    e-Library read for

Drafting of Annex ZA in relation to Mandate 129 (EC Directive 89/106).

  • Amendment
    9 pages
    English language
    e-Library read for

Drafting of Annex J concerning traceability of the thermal output measurement of radiators and convectors.

  • Amendment
    5 pages
    English language
    e-Library read for

Definition of the test method and the test installation for determinating the thermal output of ceiling mounted radiant panels.

  • Standard
    32 pages
    English language
    e-Library read for

Definition of the test method for determining the thermal output of prefabricated ceiling mounted radiant panels fed with water at temperature below 120°C supplied from a remote source.

  • Standard
    8 pages
    English language
    e-Library read for

Definition of technical specifications and requirements of prefabricated hot water radiant panels fed with water at temperatures below 120°C supplied by a remote heat source and definition of the additional common data that the manufacturer shall provide to the trade in order to ensure the correct application of the products. The document does not apply to independent heating appliances.

  • Standard
    19 pages
    English language
    e-Library read for

The amendment to be drafted to cover Kachelofen and Putzofen appliances.

  • Amendment
    22 pages
    English language
    e-Library read for
  • Amendment
    21 pages
    German language
    e-Library read for

This standard applies to flued oil stoves with one or more vaporizing burners (hereafter referred to as 'stoves') as used for individual heating in the domestic field and having either a draught regulator or a combustion air limiter as defined in 3.13 and a nominal heating capacity of not more than 15 kW. It is not applicable for built-in equipment.

  • Standard
    31 pages
    English language
    e-Library read for

This European Standard specifies requirements relating to the design, manufacture, construction, safety and performance (efficiency and emission), instructions and marking together with associated test methods for type testing, residential open fires and inset appliances fired by solid fuel.
This standard is applicable to hand fired appliances which are listed under categories 1b, 1c, 2b, 2c, 3a, 3b and 3c of Table 1. The surround of the appliances is integrated with the building with the exception of free-standing appliances and inset appliances which are installed into a fireplace recess or enclosure.
This standard is not applicable to appliances with fan assisted combustion air.
These appliances provide heat into the space where they are installed.  Additionally, where fitted with a boiler, they also provide domestic hot water and/or central heating.  They may burn either solid mineral fuels, peat briquettes, natural or manufactured wood logs or be multi-fuel in accordance with the appliance manufacturer's instructions.
Open fireplace components such as a bottomgrate with associated firefront which the manufacturer supplies for installation into an existing heat resistant, insulated firebox are not covered by this standard.

  • Standard
    72 pages
    English language
    e-Library read for
  • Standard
    63 pages
    German language
    e-Library read for
  • Standard – translation
    84 pages
    Slovenian language
    e-Library read for

This European Standard specifies requirements relating to the design, manufacture, construction, safety and performance (efficiency and emission) instructions and marking together with associated test methods and test fuels for type testing residential roomheaters fired by solid fuel.
This Standard is applicable to non-mechanically fired appliances which are listed under categories 1a and 2a of Table 1. These appliances provide heat into the space where they are installed. Additionally, where fitted with a boiler, they also provide domestic hot water and/or central heating. These appliances may burn either solid mineral fuels, peat briquettes, natural or manufactured wood logs or be multi-fuel in accordance with the appliance manufacturer's instructions.
This standard is not applicable to appliances with fan assisted combustion air.

  • Standard
    64 pages
    English language
    e-Library read for

This European Standard specifies requirements relating to the design, manufacture, construction, performance (efficiency and emission), safety, instructions and marking together with associated test methods and test fuels for type testing residential independent boilers fired by solid fuel.
This standard is applicable to hand and automatically fired appliances having nominal heat outputs up to 50 kW, the primary function of which is to provide hot water for central heating and/or domestic use, and which are designed for use only with open vented systems at a working pressure not exceeding 2 bar. In addition to their primary function of providing hot water these appliances also provide space heating to the place of installation. These appliances may burn either solid mineral fuels, peat briquettes or natural or manufactured wood logs or be multi-fuel in accordance with the appliance manufacturer's instructions.
This standard is not applicable to independent boilers for hot water only production and having heat outputs of less than 5 kW.
This standard is also not applicable to the design and construction of automatic stoking devices.

  • Standard
    60 pages
    English language
    e-Library read for
  • Standard
    48 pages
    German language
    e-Library read for

Frequently Asked Questions

A European Standardization Mandate is a formal request from the European Commission to the European Standardization Organizations (CEN, CENELEC, and ETSI) to develop European standards (ENs) in support of EU legislation and policies. Mandates are issued under Regulation (EU) No 1025/2012 and help ensure that products and services meet the essential requirements set out in EU directives and regulations.

M/129 is a European Standardization Mandate titled "Mandate to CEN/CENELEC concerning the execution of standardization work for harmonized standards on space heating appliances". Mandate to CEN/CENELEC concerning the execution of standardization work for harmonized standards on space heating appliances There are 98 standards developed under this mandate.

Standards developed in response to a mandate and cited in the Official Journal of the European Union become "harmonized standards". Products manufactured in compliance with harmonized standards benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation, facilitating CE marking and market access across the European Economic Area.