This document specifies requirements for storm water management systems on wastewater treatment plants. It does not refer to storm water management systems in wastewater collection and conveyance networks (sewer systems). Regardless of the location and the technical requirements of this document, storm water management systems can be regarded as part of the sewer system in accordance with EN 752 and EN 16933.
This document specifies requirements for separation, storage, treatment, discharge and return of storm water within wastewater treatment plants.
NOTE A storm water management system at the wastewater treatment plant is only required where such a system is not provided within the sewer system, limiting the flow to the wastewater treatment plants see EN 752 and EN 16933 (all parts).

  • Standard
    14 pages
    English language
    e-Library read for
    ×1 day

This document specifies an analysing methodology for protecting potable water in potable water installations within and outside buildings but within premises from the risk of pollution by backflow of non-potable water and gives recommendations on the design, risk analysis, backflow prevention devices and their installation methods (see Figure 1 and Figure 2).
This methodology is also intended to be used outside premises for all water systems connected to a potable water distribution system up to and including the point of use (see Figure 3).
The product standards for the specific backflow prevention devices or arrangements are intended to be used in conjunction with this document. For the development of new devices or systems, this document is intended to be used as a reference to establish the necessary level of backflow protection.

  • Standard
    67 pages
    English language
    e-Library read for
    ×1 day

This document specifies the methods used for the chemical analyses and the determination of physical properties of calcium carbonate, high-calcium lime, half-burnt dolomite, magnesium oxide, calcium magnesium carbonate and dolomitic lime used to treat water for human consumption.
This document specifies the reference methods and, in certain cases, an alternative method which can be considered to be equivalent.

  • Standard
    70 pages
    English language
    e-Library read for
    ×1 day

This document of the EN 12255 series specifies design principles and performance requirements for secondary and tertiary treatment of wastewater in biological fixed-film reactors at wastewater treatment plants for more than 50 PT.
Its primary application is for wastewater treatment plants for the treatment of domestic and municipal wastewater. It can also be applied for biodegradable industrial wastewater.
Biological fixed film reactors include rotating biological contactors (RBC), biological trickling reactors (BTR), moving bed biological reactors (MBBR), submerged medium reactors (SMR) and submerged media filters (SMF). Membrane bioreactors (MBR) and anaerobic processes are not within the scope.
Some of the systems using fixed film bacteria are enhanced activated sludge systems (hybrid systems). For such systems, EN 12255-6 also applies.
This document specifies fundamental information about typical systems and does not provide information about all available fixed film systems.

  • Standard
    32 pages
    English language
    e-Library read for
    ×1 day

This document is applicable to calcium carbonate used for treatment of water intended for human consumption. It describes the characteristics of calcium carbonate and specifies the requirements and the corresponding test methods for calcium carbonate. It gives information on its use in water treatment.

  • Standard
    14 pages
    English language
    e-Library read for
    ×1 day

This document specifies a procedure for obtaining a migration water to determine odour, flavour, colour and turbidity for products made from organic materials intended to come in contact with water for human consumption (drinking water) and used in piping and storage systems. Such products include pipes, tanks, reservoirs, fittings, ancillaries and their coatings both for site applied and factory-made products.
This document is applicable to products to be used under various conditions for the transport, storage and distribution of water intended for human consumption and raw water used for the manufacture of water intended for human consumption.
This document specifies a test method comprising a set of procedures. The use may be dependent on the relevant national regulations and/or the Commission Implementing Decision (EU) 2024/368.

  • Standard
    27 pages
    English language
    e-Library read for
    ×1 day

This document specifies definitions, principles of construction (but not dimensions) and design, requirements on performance and operation as well as methods for testing the performance of adjustable chemical dosing systems for conditioning water intended for human consumption inside buildings (see [1]) which are permanently connected to the mains supply.

  • Standard
    18 pages
    English language
    e-Library read for
    ×1 day

This document specifies a procedure to determine the release of metals from metallic materials used in products intended to come into contact with drinking water.
The test can be used for three purposes:
a)   To assess a material as a reference material for a new category of materials by metal release testing using the results of several investigations in different waters covering a broad range of water compositions;
b)   To assess a material for an existing category for approval by way of metal release testing using the water defined in part 2, which exhibited the highest metal release when the reference material of the category was tested;
c)   To obtain data on the interaction of local water with a material.

  • Standard
    31 pages
    English language
    e-Library read for
    ×1 day

This document is applicable to flushing valves for WCs and valves for urinals, with automatic hydraulic closure, intended for:
—   WC pans EN 997;
—   single flush urinals EN 13407;
—   siphon acting urinals EN 13407.
It does not apply to no-contact detection valves.
It is intended to specify:
—   marking and identification, physico-chemical, dimensional, leaktightness, pressure behaviour, hydraulic, mechanical endurance and acoustic characteristics of flushing valves for WCs and urinals with automatic closure;
—   test methods used to verify these characteristics;
—   and to determine requirements for the atmospheric interrupter which shall be an integral part of the WC flushing valve.
It is applicable in the following pressure and temperature conditions (see Table 1):
[Table 1 — Conditions of use for tapware]
NOTE   Although this document limits the pressure for WC DN25 and WC DN32 valves till 0,25 MPa (2,5 bar), some European countries have legislation and recommendations for higher pressures.
Health and quality requirements in accordance to European and national legislation for final materials in contact with water intended for human consumption are not covered by this document.

  • Standard
    36 pages
    English language
    e-Library read for
    ×1 day

This document specifies general construction, performance and material requirements for PN 10 thermostatic mixing valves (TMV) and includes test methods for the verification of mixed water temperature performance at the point of use below 45 °C. This does not exclude the selection of higher temperatures where available. When these devices are used to provide anti-scald protection for children, elderly and disabled persons the mixed water temperature shall be set at a suitable temperature (body temperature - 38 °C). In particular children are at risk to scalding at lower temperatures than adults. This does not obviate the need for supervision of young children.
It applies to valves intended for use on sanitary appliances in kitchens, washrooms (incl. all rooms with sanitary tapware, e.g. toilet and cloakrooms) and bathrooms operating under the conditions specified in Table 1.
This document allows TMVs to supply a single outlet or a small number of outlets in a “domestic” application (e.g. one valve, controlling a shower, bath, basin and/or, bidet), excluding valves specifically designed for supplying a large number of outlets (i.e. for institutional use).
The tests described are type tests (laboratory tests) and not quality control tests carried out during manufacture.

  • Standard
    57 pages
    English language
    e-Library read for
    ×1 day

This document is applicable to sodium hypochlorite used directly or for the production of formulations for treating swimming pool and spas water. It describes the characteristics of sodium hypochlorite and specifies the requirements and the corresponding test methods for sodium hypochlorite. It gives information on its use for treating swimming pool and spas water.

  • Standard
    17 pages
    English language
    e-Library read for
    ×1 day

This document specifies general construction, performance and material requirements for PN 10 thermostatic mixing valves (TMV) and includes test methods for the verification of mixed water temperature performance at the point of use below 45 °C. This does not exclude the selection of higher temperatures where available. When these devices are used to provide anti-scald protection for children, elderly and disabled persons, the mixed water temperature needs to be set at a suitable temperature (body temperature approximately 38 °C). In particular children are at risk to scalding at lower temperatures than adults. This does not obviate the need for supervision of young children.
It applies to valves intended for use on sanitary appliances in kitchens, washrooms (incl. all rooms with sanitary tapware, e.g. toilets and cloakrooms) and bath rooms operating under the conditions specified in Table 1.
This document allows TMVs to supply a single outlet or a small number of outlets in a “domestic” application (e.g. one valve controlling a shower, bath, basin and/or bidet), excluding valves specifically designed for supplying a large number of outlets (i.e. for institutional use).
The tests described are type tests (laboratory tests) and not quality control tests carried out during manufacture.
Table 1 - Conditions of use
[...table not reproduced...]

  • Standard
    59 pages
    English language
    e-Library read for
    ×1 day

This document is applicable to ozone used for treatment of water for swimming pools and spas. It describes the composition of ozone. It gives information on its use in swimming pool and spas water treatment. It also determines the rules relating to safe handling and use (see Annex B).

  • Standard
    18 pages
    English language
    e-Library read for
    ×1 day

This document specifies requirements for dosing systems for chlorine dioxide generation according to the chlorite-chlorine gas process, the chlorite-acid process and the chlorite-sodium peroxodisulphate process, which are used for the disinfection and oxidation of substances in water.
The chlorine dioxide (ClO2) solution is produced on site (in situ) by automated mixing of chemical precursors.
NOTE   According to EN 12671, chlorine dioxide is suited for the use of the treatment of water intended for human consumption (drinking water).

  • Standard
    54 pages
    English language
    e-Library read for
    ×1 day

ISO 24516-1:2016 specifies guidelines for technical aspects, tools and good practices for the management of assets of drinking water networks to maintain value from existing assets.
ISO 24516-1:2016 does not apply to the management of assets of waterworks (including catchment and treatment, pumping and storage in the network), which are also physically part of the drinking water system and can influence the management of assets of the pipe network.
ISO 24516-1:2016 focuses on the assets typically owned or operated by drinking water utilities (networked drinking water systems) that are expected to meet customer needs and expectations over longer (multi-generational) periods.
ISO 24516-1:2016 includes examples for good practice approaches on the strategic, tactical and operational levels.
ISO 24516-1:2016 is applicable to all types and sizes of organization and/or utilities operating drinking water systems, and all different roles/functions for the management of assets within a utility (e.g. asset owner/responsible body, asset manager/operator, service provider/operator).

  • Standard
    52 pages
    English language
    e-Library read for
    ×1 day
  • Standard
    45 pages
    English language
    sale 15% off
  • Standard
    45 pages
    English language
    sale 15% off
  • Standard
    47 pages
    French language
    sale 15% off
  • Standard
    47 pages
    French language
    sale 15% off

This document considers liquid atmospheric precipitation (rain) and defines the procedures and equipment to perform laboratory tests, in steady-state conditions, for the calibration, check and metrological confirmation of non-catching rainfall measurement instruments. This document is not applicable to field performance.
It provides a classification of non-catching measurement instruments based on their laboratory performance. The classification does not relate to the physical principle used for the measurement, nor does it refer to the technical characteristics of the instrument assembly but is solely based on the instrument calibration.
Attribution of a given class to an instrument is not intended as a high/low ranking of its quality but rather as a quantitative standardized method to declare the achievable measurement accuracy to provide guidance on the suitability for a particular purpose, while meeting the user’s requirements.

  • Standard
    20 pages
    English language
    e-Library read for
    ×1 day

This document specifies the characteristics and the requirements of air gap with injector Family A, Type D for nominal flow velocity not exceeding 3 m/s. Air gaps are devices for protection of potable water in water installations from pollution by backflow. This document is applicable to air gaps in factory-assembled products and to constructed air gaps in situ and specifies requirements and methods to verify and ensure compliance with this document during normal working use.
The fluid in the receiving vessel is assumed to have similar properties to the water supply. Where this is not the case, additional care or tests can be required to verify the efficacy of the solution in practical use.
The AD device is intended to be used in potable water installations according to EN 806 (all parts).

  • Standard
    13 pages
    English language
    e-Library read for
    ×1 day

This document specifies and gives guidance on:
—   general requirements for storage of water outside consumers' buildings, including service reservoirs for potable water and reservoirs containing water not for human consumption at intake works or within treatment works, excluding those that are part of the treatment process;
—   design;
—   general requirements for product standards;
—   requirements for quality control and auditing, testing and commissioning;
—   operational requirements;
—   requirements for inspection, rehabilitation and repair.
The requirements of this document are applicable to:
—   design and construction of new reservoirs;
—   extension and modification of existing reservoirs;
—   significant rehabilitation of existing reservoirs.
This document does not apply to reservoirs formed by the building of dams or the use of lakes for water storage purposes.

  • Standard
    41 pages
    English language
    e-Library read for
    ×1 day

The purpose of this document is to specify requirements for marking, identification, leaktightness, electrical and operational safety and mechanical resistance for sanitary tapware with opening and closing controlled electronically.
The conditions of use for the supply system type are specified in Table 2:
[Table 2]
Annex B lists possible consequences of using a product outside its recommended operating range.
[Figure 1]
[Figure 2]

  • Corrigendum
    4 pages
    English language
    e-Library read for
    ×1 day

This document is applicable to half-burnt dolomite used for treatment of water intended for human consumption. It describes the characteristics of half-burnt dolomite and specifies the requirements and the corresponding test methods for half-burnt dolomite. It gives information on its use in water treatment.

  • Standard
    15 pages
    English language
    e-Library read for
    ×1 day

This document acknowledges the field of application for taps, shower outlets, shower sets and shower systems used in water supply systems with a pressure range of (0,05 to 1,0) MPa [(0,5 to 10) bar].
The tests described in this document are type tests (laboratory tests) and not quality control tests carried out during manufacture.
This document covers:
—   PN10 taps;
—   PN5 shower outlets;
—   PN5 shower sets;
—   PN10 shower systems.
The following products are excluded from this document:
—   shower taps on its own;
—   taps for filling bathtubs;
—   the tub filling function of combined taps;
—   the function of a tap that delivers e.g. boiling water or sparkling water, etc.;
—   body or side jet showers.
The conditions of use for taps and shower systems are given in Table 1. The conditions of use for showers sets and shower outlets are given in Table 2.
Table 1 — Conditions of use for taps and shower systems
Water supply system   Operating range of taps and shower systems
   Limits   Recommended
see Figure 1   dynamic pressure
≥ 0,05 MPa
(0,5 bar)
static pressure
≤ 1,0 MPa
(10,0 bar)   dynamic pressure b
(0,1 to 0,5) MPa
[(1,0 to 5,0) bar]
temperature   ≤ 70 °C a   ≤ 65 °C
a   This maximum temperature limit can only be reached for short durations not greater than 1 h.
b   Measured at the point of discharge.
NOTE   Taps and shower systems for use at pressures lower than those in Table 1 are not covered by this standard.
Table 2 — Conditions of use for shower outlets and shower sets
Water supply system   Operating range of showers
   Limits   Recommended
see Figure 1   dynamic pressure
≥ 0,05 MPa
(0,5 bar)
static pressure
≤ 0,5 MPa
(5,0 bar)   dynamic pressure
(0,1 to 0,3) MPa
[(1,0 to 3,0) bar]
temperature   ≤ 70 °C a   ≤ 42 °C
a   This maximum temperature limit can only be reached for short durations not greater than 1 h.
Key
1   cold water
2   hot water
3   mains supply pipe (supply pressures up to 10 bar)
4   water heater
Figure 1 — Supply system with a pressure range of (0,05 to 1,0) MPa [(0,5 to 10) bar]
Health and quality requirements in accordance to European and national legislation for final materials in contact with water intended for human consumption are not covered by this document.

  • Standard
    41 pages
    English language
    e-Library read for
    ×1 day

This document specifies a method to determine the migration of substances from hardened cement based site-applied or site-formed materials (including pre-packaged mortars) into test waters after contact with the products. It also covers determination of migration from individual constituents of cement based products and materials (see Annexes A and B) and from associated non-cement based products for approval purposes (see Annex C).
Site-applied or site-formed cement based materials which cannot be cast as cubes or prisms e.g. some spray applied systems, fall in the scope of EN 14944−3 and not under this standard.
This document is applicable to site-applied or site-formed cement based materials intended to be used for the transport and storage of water intended for human consumption, including raw water used for the production of drinking water. It is also applicable to individual constituents of cement based products/materials and to associated non-cement based products/materials.
NOTE   Tests with the specified test water will not necessarily be representative of materials used in different kinds of waters and especially very soft waters.

  • Standard
    54 pages
    English language
    e-Library read for
    ×1 day

This document specifies a method to determine the influence of site-applied cement based materials and associated non-cement based products/materials (including pre-packaged mortars) on the odour, flavour, colour, turbidity and total organic carbon (TOC) of test waters after contact with the products.
This document is applicable to site-applied or site-formed cement based materials intended to be used for the transport and storage of water intended for human consumption, including raw water used for the production of drinking water. It is also applicable to individual constituents of cement based products/materials and to associated non-cement based products/materials.
Site-applied or site-formed cement based materials which cannot be cast as cubes or prisms e.g. some spray applied systems, should be tested as factory made cement based products according to EN 14944−1.
NOTE   Tests with the specified test water will not necessarily be representative of materials used in different kinds of waters and especially very soft waters.

  • Standard
    56 pages
    English language
    e-Library read for
    ×1 day

This document applies primarily to copper alloy and stainless steel ball valves with dimensions DN 6 to DN 100, for installations in buildings for potable water supply up to PN16 and a maximum distribution temperature of 65 °C. Occasional excursions up to 90 °C are permitted for a period of 1 h maximum.
The ball valves are classified by their nominal pressure being either PN10 or PN16.
This document specifies:
-   the requirements of the materials and the design of ball valves;
-   the mechanical, hydraulic and acoustic requirements of ball valves;
-   the test methods to verify the requirements of ball valves;
-   the marking requirements of ball valves.

  • Standard
    28 pages
    English language
    e-Library read for
    ×1 day

This document specifies:
-   general requirements for water supply systems outside buildings including potable water mains and service pipes, service reservoirs, other facilities and raw water mains but excluding treatment works and water resources development;
-   general requirements for components;
-   general requirements for inclusion in product standards which can include specifications which are more stringent;
-   general requirements for installation, site testing and commissioning.
The requirements of this document apply to:
-   the design and construction of new water supply systems;
-   the extension of significant areas forming a coherent part of an existing water supply system;
-   interconnections between water supply systems;
-   significant modification and/or rehabilitation of existing water supply systems.
NOTE   It is not intended that existing water supply systems are altered to comply with this document, provided that there are no significant detrimental effects on water quantity, security, reliability and adequacy of the supply. However, this document is intended to cover all water infrastructure systems mentioned above since they are key to meet the sustainable goals of the cities and to show the urgent need to invest in them in order to consider fundamental aspects, such as resilience or mitigation/adaptation to climate change.

  • Standard
    86 pages
    English language
    e-Library read for
    ×1 day

This document is applicable to sodium hypochlorite used for treatment of water intended for human consumption. It describes the characteristics of sodium hypochlorite and specifies the requirements and the corresponding test methods for sodium hypochlorite. It gives information on its use in water treatment. It also determines the rules relating to safe handling and use of sodium hypochlorite (see Annex B).
NOTE   While this document is not applicable to sodium hypochlorite generated in situ (see bibliographic reference [6]), the limits for impurities and chemical parameters apply.

  • Standard
    38 pages
    English language
    e-Library read for
    ×1 day

This document is applicable to glass beads and glass granulate intended for treatment of water for human consumption, swimming pool and/or spa water. It solely describes the characteristics of glass beads and glass granulate and specifies the requirements and the corresponding test methods for glass beads and glass granulate.
General information on glass beads and glass granulate and general rules relating to safety is provided in Annex A.

  • Standard
    16 pages
    English language
    e-Library read for
    ×1 day

This document specifies additional requirements to the product standards given in Clause 5 for valves and devices to prevent pollution by backflow of potable water with polymer parts and housings under internal pressure and without external loads intended for installations and equipment inside buildings conveying water for human consumption.

  • Standard
    12 pages
    English language
    e-Library read for
    ×1 day

This document is applicable to ammonia solution used for treatment of water intended for human consumption. It describes the characteristics and specifies the requirements of ammonia solution and refers to the corresponding analytical methods. It gives information for its use in water treatment. It also provides basic information relating to safe handling and use of ammonia solution (see Annex B).

  • Standard
    20 pages
    English language
    e-Library read for
    ×1 day

This document is applicable to aluminium-based coagulants used for treatment of water intended for human consumption. It specifies analytical methods to be used for products described in EN 878, EN 882, EN 885, EN 886, EN 887, EN 935 and EN 17034.

  • Standard
    53 pages
    English language
    e-Library read for
    ×1 day

This document specifies the basic design and construction requirements for wastewater treatment plants for over 50 PT.
NOTE 1   Requirements for structures which are not specific for wastewater treatment plants are not within the scope of this document. Other ENs can apply.
NOTE 2   Equipment which is not solely used in wastewater treatment plants is subject to the applicable product standards. However, specific requirements for such equipment when used in wastewater treatment plants are included in this part.
NOTE 3   Although this document specifies the basic design and construction requirements for wastewater treatment plants for over 50 PT, many requirements are only technically and economically feasible at significantly larger sizes.

  • Standard
    31 pages
    English language
    e-Library read for
    ×1 day

This document specifies:
a)   the field of application for mechanical mixing valves for use in a supply system of Type 1 (see Figure 1);
b)   the dimensional, leaktightness, pressure resistance, hydraulic performance, mechanical strength, endurance, corrosion resistance of the surface of the product, sequence of testing and acoustic characteristics with which sanitary tapware products including their components (flexible hose, pull out spray) need to comply where applicable;
c)   test methods to verify the characteristics.
The tests described in this document are type tests (laboratory tests) and not quality control or factory production control (FPC) tests carried out during manufacture.
This document applies to draw-off taps (mechanical mixing valves) for use with sanitary appliances installed in rooms used for personal hygiene (cloakrooms, bathrooms, etc.) and for food preparation (kitchens), i.e. for use with baths, wash basins, bidets, showers and sinks.
The conditions of use and classifications are given in Table 1.
[Table 1]
Figure 1 shows a supply system of Type 1 with a pressure range of (0,05 to 1,0) MPa [(0,5 to 10) bar].
[Figure 1]
Final materials included in the product are not covered by this document.

  • Standard
    53 pages
    English language
    e-Library read for
    ×1 day

This document is applicable to devices for the generation and dosing of ozone. The ozone is generated in these devices according to the technology of dielectric barrier discharge. According to EN 1278 and EN 15074, ozone is suited for the use of the treatment of water intended for human consumption (drinking water), and for the treatment of swimming pool water respectively. Ozone can be added to the water for disinfection and for oxidative purposes. This document can also be applied for other technologies to generate ozone, e.g. electrolysis or UV irradiation, as far as reasonable or applicable.
This document specifies device’s construction, and test methods for the equipment used for in situ generation of ozone. It also specifies requirements for instructions for installation, operation, maintenance, safety and for documentation to be provided with the product.

  • Standard
    39 pages
    English language
    e-Library read for
    ×1 day

This document specifies:
- general construction, performance and material requirements for Frost Resistant Taps for outdoor use (FRT), PN 10.
- the application in the potable water installation with a static pressure of maximum 1,0 MPa (10 bar) and a distribution temperature of maximum 25 °C (PWC).
FRT valves shall consist of the 3 areas shown in Figure 1.
The conditions of use are according to the following Table 1.
The requirements with regard to the potable water quality are specified in national regulations.

  • Corrigendum
    3 pages
    English language
    e-Library read for
    ×1 day

This document specifies design principles and performance requirements for sludge treatment and storage facilities at wastewater treatment plants serving more than 50 PT.
Guidance on operation is provided where it is necessary in order to facilitate the design of control and automation and design access to points of operation.
NOTE   Other sludges and organic wastes can be treated together with municipal sewage sludge where national and local regulations permit.

  • Standard
    45 pages
    English language
    e-Library read for
    ×1 day

This document is applicable to sulphamic acid used as antifoulant for membranes in the treatment of water intended for human consumption. It describes the characteristics and specifies the requirements and the corresponding analytical methods for sulphamic acid. It gives information on their use as antifoulant for membranes in water treatment in Annex A.

  • Standard
    19 pages
    English language
    e-Library read for
    ×1 day

This document is applicable to lagoons and specifies the performance requirements for the installation of lagooning processes.
This document applies to wastewater lagooning processes treating municipal wastewater from combined or separate sewage systems and when used as a tertiary treatment.
NOTE   Lagoon systems are especially suitable for the treatment of wastewater where large flow variations occur (e.g. arising from surface water connections in the collection system). They are also especially suitable where large load variations occur (e.g. arising from fluctuating seasonal or industrial flows).

  • Standard
    14 pages
    English language
    e-Library read for
    ×1 day

The purpose of this document is to specify requirements for marking, identification, leaktightness, electrical and operational safety and mechanical resistance for sanitary tapware with opening and closing controlled electronically.
The conditions of use for the supply system type are specified in Table 2:
[Table 2]
Annex B lists possible consequences of using a product outside its recommended operating range.
[Figure 1]
[Figure 2]

  • Standard
    53 pages
    English language
    e-Library read for
    ×1 day

This document specifies general requirements for instrumentation and specific requirements for process control and automation systems on wastewater treatment plants for more than 50 PT.
NOTE 1   Because of the rapid rate of development of sensor and control equipment, this document is intended as an overview and uses examples and general requirements, not detailed equipment specifications. Detailed information additional to that contained in this document can be obtained by referring to the Bibliography.
NOTE 2   Although EC directives become matters of law in member states of the EU and some other situations, this standard is intended for wider use and hence those directives with clear technical guidance of a type that would generally be appropriate in a standard are referenced in the text and listed in the Bibliography. The alternative of listing requirements copied from directives would potentially create unacceptable conflict when directives are revised.

  • Standard
    26 pages
    English language
    e-Library read for
    ×1 day

This document specifies the requirements and gives recommendations for the design, sizing, installation, identification, commissioning and maintenance of rainwater harvesting systems for the use of rainwater on-site as non-potable water. This document also specifies the minimum requirements for these systems.
Excluded from the scope of this document are
-   the use as drinking water and for food preparation,
-   the use for personal hygiene purposes,
-   attenuation and
-   infiltration.
NOTE   Conformity with the document does not exempt from compliance with the obligations arising from local or national regulations.

  • Standard
    39 pages
    English language
    e-Library read for
    ×1 day

This document specifies design principles and performance requirements for preliminary wastewater treatment using screens with a mesh size above 50 μm, at plants serving more than 50 PT. It also includes grit removal and grease separation.
NOTE 1   For micro-screens with a mesh size below 50 microns see EN 12255-16.
NOTE 2   The primary application of this document is for wastewater treatment plants designed for the treatment of domestic and municipal wastewater. However, it contains information that can also be useful for commercial and industrial wastewater pretreatment and for combined sewer overflows (CSO).
This document applies in combination with EN 12255-1 and EN 12255-10.

  • Standard
    37 pages
    English language
    e-Library read for
    ×1 day

This European Standard specifies a method to determine the migration of substances from factory made cementitious products into test waters after contact with the products.
This European Standard is applicable to factory made cementitious products, e.g. cement mortar linings to metallic pipes, tanks, concrete pipes etc., intended to be used for the transport and storage of water intended for human consumption, including raw water used for the production of drinking water.

  • Standard
    56 pages
    English language
    e-Library read for
    ×1 day

This document defines the minimum requirements for treatment systems, which generate the active substance - “Active chlorine” - from sodium chloride by electrolysis for on-site (in situ) operation.
The in situ generated active substance (IGAS), in this case active chlorine, may be put into a solution (“off-line”) or directly generated in the pipes (“in-line”).
This document specifies the device construction, and test methods for the equipment used for in situ generation of active chlorine. It specifies requirements for instructions for installation, operation, maintenance, safety and for documentation to be provided with the product.
The in situ generation of active substances and the placing of their precursors on the EU market are subject to the specifications of the Biocidal Products Regulation (EU) 528/2012 [“Biocidal products”]. Active substances, generated by devices, which are claiming compliance with this document, shall comply with the BPR for both the registered active chlorine, quality standards and the precursor in accordance with appropriate application and “Product Type” as listed in the BPR.
This standard does not identify applications for in situ devices for generation of active chlorine. The range of applications for in situ generation of chlorine is diverse. It is the responsibility of the economic operator/product supplier, claiming compliance with this standard, to identify the appropriate system type and operating conditions for the specific application and to:
-   specify the quality of the biocide appropriate to the application. This may be defined in national or international standards;
-   specify the appropriate product type and operating conditions (concentration, dosage rate and quality of the active chlorine);
-   specify any other regulatory requirements relevant to the specific application;
-   specify the appropriate precursor sodium chloride, for the application;
-   and to label the product accordingly.

  • Standard
    43 pages
    English language
    e-Library read for
    ×1 day

This document specifies:
a)   the field of application for pillar taps, bib taps, single and multi-hole combination taps for use in:
1)   a supply system of Type 1 (see Figure 1) with a pressure range of (0,05 to 1,0) MPa [(0,5 to 10) bar];
2)   a supply system of Type 2 (see Figure 2) with a pressure range of (0,01 to 1,0) MPa [(0,1 to 10) bar];
b)   the dimensional, leak tightness, pressure resistance, hydraulic performance, mechanical strength, endurance, corrosion resistance of the surface of the product, sequence of testing and acoustic characteristics with which sanitary tapware products including their components (flexible hose, pullout spray) need to comply where applicable;
c)   test methods to verify the characteristics.
The tests described in this document are type tests (laboratory tests) and not quality control or factory production control (FPC) tests carried out during manufacture.
This document is applicable to draw-off taps (single taps and combination taps) for use with sanitary appliances installed in rooms used for personal hygiene (cloakrooms, bathrooms etc.) and for food preparation (kitchens), i.e. for use with baths, basins, bidets, showers and sinks.
This document applies to sanitary draw-off taps of nominal size 3/8”, 1/2", 3/4" and 1” (PN 10).
The conditions of use and classifications are given in Table 1.
Table 1 - Conditions of use
[ table not reproduced here ]
[ figure not reporduced here ]
Figure 1- Supply system of Type 1 with a pressure range of (0,05 to 1,0) MPa [(0,5 to 10) bar]
[ figure not reporduced here ]
Figure 2 - Supply system of Type 2 with a pressure range of (0,01 to 1,0) MPa [(0,1 to 10) bar]
NOTE   Components which are part or can be delivered with sanitary tapware products are listed in Annex C.
Final materials included in the product are not covered by this document.

  • Standard
    54 pages
    English language
    e-Library read for
    ×1 day

This document specifies design principles and performance requirements for odour control and associated ventilation for wastewater treatment plants serving more than 50PT.

  • Standard
    24 pages
    English language
    e-Library read for
    ×1 day

This document is applicable to cationic polyacrylamides used for treatment of water intended for human consumption. It describes the characteristics of cationic polyacrylamides and specifies the requirements and the corresponding test methods for cationic polyacrylamides. It gives information on their use in water treatment.

  • Standard
    19 pages
    English language
    e-Library read for
    ×1 day

This document is applicable to poly(diallyldimethylammonium chloride) used for treatment of water intended for human consumption. It describes the characteristics of poly(diallyldimethylammonium chloride) and specifies the requirements and the corresponding test methods for poly(diallyldimethylammonium chloride). It gives information on their use in water treatment.

  • Standard
    21 pages
    English language
    e-Library read for
    ×1 day

This European Standard specifies a method to determine the influence of factory made cementitious products on the odour, flavour, colour and turbidity of test waters after contact with the products.
This European Standard is applicable to factory made cementitious products, e.g. cement mortar linings to metallic pipes, tanks, concrete pipes etc. intended to be used for the transport and storage of water for human consumption, including raw water used for the production of drinking water.

  • Standard
    58 pages
    English language
    e-Library read for
    ×1 day

Frequently Asked Questions

IOVO is a Technical Committee within the Slovenian Institute for Standardization (SIST). It is named "Water supply and waste water engineering" and is responsible for: Standardization in the field of water supply, sanitary appliances and waste water engineering. This committee has published 928 standards.

IOVO develops SIST standards in the area of Building and Construction. The scope of work includes: Standardization in the field of water supply, sanitary appliances and waste water engineering. Currently, there are 928 published standards from this technical committee.

The Slovenian Institute for Standardization (SIST) is the national standards body of Slovenia. SIST adopts European and international standards as Slovenian national standards and develops original Slovenian standards where needed. As a member of ISO, IEC, CEN, and CENELEC, SIST represents Slovenian interests in international standardization.

A Technical Committee (TC) in SIST is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.

Loading...