This document specifies the characteristics of fittings for crosslinked polyethylene (PE-X) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption (domestic systems) and for heating systems under design pressures and temperatures according to the class of application (see ISO 15875-1:—, Table 1).
This document also specifies the test parameters for the test methods referred to herein.
This document is applicable to fittings made from PE-X or other plastics or non-plastics materials, which are intended to be connected to pipes conforming to ISO 15875-2 for hot and cold water installations, whereby the joints conform to the requirements of ISO 15875-5.
This document is applicable to fittings of the following types:
—     mechanical fittings;
—     electrofusion fittings;

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the general aspects of crosslinked polyethylene (PE-X) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption (domestic systems), and for heating systems, under design pressures and temperatures according to the class of application (see Table 1).
This document also specifies the basis for the test parameters for the test methods referred to in the ISO 15875 series.
This document covers a range of service conditions (application classes), design pressures and pipe dimension classes. The ISO 15875 series does not apply to values of design temperature (TD), maximum temperature (Tmax) and malfunction temperature (Tmal), as well as service times in excess of those defined in Table 1.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of the fitness for purpose of crosslinked polyethylene (PE-X) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water whether or not intended for human consumption (domestic systems), and for heating systems, under design pressures and temperatures appropriate to the class of application (see ISO 15875-1:2025, Table 1).
This document also specifies the test parameters for the test methods referred to herein.
This document is applicable to joints between pipes conforming to ISO 15875-2 and fittings made of plastics and non-plastics materials conforming to ISO 15875-3, for hot and cold water installations.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of pipes for crosslinked polyethylene (PE-X) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water whether or not intended for human consumption (domestic systems), and for heating systems, under design pressures and temperatures according to the class of application (see ISO 15875-1:2025, Table 1).
This document also specifies the test parameters for the test methods referred to in this document.
It is applicable to PE-X pipes with and without barrier layer.
This document is applicable to PE-X pipes for hot and cold water installations, which are intended to be connected to fittings conforming to ISO 15875-3, whereby the joints conform to the requirements of ISO 15875-5.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics and the requirements of air gap with injector Family A, Type D for nominal flow velocity not exceeding 3 m/s. Air gaps are devices for protection of potable water in water installations from pollution by backflow. This document is applicable to air gaps in factory-assembled products and to constructed air gaps in situ and specifies requirements and methods to verify and ensure compliance with this document during normal working use.
The fluid in the receiving vessel is assumed to have similar properties to the water supply. Where this is not the case, additional care or tests can be required to verify the efficacy of the solution in practical use.
The AD device is intended to be used in potable water installations according to EN 806 (all parts).

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics and the requirements of air gap with injector Family A, Type D for nominal flow velocity not exceeding 3 m/s. Air gaps are devices for protection of potable water in water installations from pollution by backflow. This document is applicable to air gaps in factory-assembled products and to constructed air gaps in situ and specifies requirements and methods to verify and ensure compliance with this document during normal working use.
The fluid in the receiving vessel is assumed to have similar properties to the water supply. Where this is not the case, additional care or tests can be required to verify the efficacy of the solution in practical use.
The AD device is intended to be used in potable water installations according to EN 806 (all parts).

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of fittings for crosslinked polyethylene (PE-X) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption (domestic systems) and for heating systems under design pressures and temperatures according to the class of application (see ISO 15875-1:—, Table 1).
This document also specifies the test parameters for the test methods referred to herein.
This document is applicable to fittings made from PE-X or other plastics or non-plastics materials, which are intended to be connected to pipes conforming to ISO 15875-2 for hot and cold water installations, whereby the joints conform to the requirements of ISO 15875-5.
This document is applicable to fittings of the following types:
—     mechanical fittings;
—     electrofusion fittings;

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of the fitness for purpose of crosslinked polyethylene (PE-X) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water whether or not intended for human consumption (domestic systems), and for heating systems, under design pressures and temperatures appropriate to the class of application (see ISO 15875-1:2025, Table 1).
This document also specifies the test parameters for the test methods referred to herein.
This document is applicable to joints between pipes conforming to ISO 15875-2 and fittings made of plastics and non-plastics materials conforming to ISO 15875-3, for hot and cold water installations.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of pipes for crosslinked polyethylene (PE-X) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water whether or not intended for human consumption (domestic systems), and for heating systems, under design pressures and temperatures according to the class of application (see ISO 15875-1:2025, Table 1).
This document also specifies the test parameters for the test methods referred to in this document.
It is applicable to PE-X pipes with and without barrier layer.
This document is applicable to PE-X pipes for hot and cold water installations, which are intended to be connected to fittings conforming to ISO 15875-3, whereby the joints conform to the requirements of ISO 15875-5.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the general aspects of crosslinked polyethylene (PE-X) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption (domestic systems), and for heating systems, under design pressures and temperatures according to the class of application (see Table 1).
This document also specifies the basis for the test parameters for the test methods referred to in the ISO 15875 series.
This document covers a range of service conditions (application classes), design pressures and pipe dimension classes. The ISO 15875 series does not apply to values of design temperature (TD), maximum temperature (Tmax) and malfunction temperature (Tmal), as well as service times in excess of those defined in Table 1.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document applies to water meters used to meter the volume of cold potable water and hot water flowing through a fully charged, closed conduit. These water meters incorporate devices which indicate the integrated volume.
This document specifies criteria for the selection of single, combination and concentric water meters, associated fittings, installation, special requirements for meters, and the first operation of new or repaired meters to ensure accurate constant measurement and reliable reading of the meter.
In addition to meters based on mechanical principles, this document also applies to water meters based on electrical or electronic principles, and to water meters based on mechanical principles incorporating electronic devices, used to measure the volume of cold potable water and hot water. It also applies to electronic ancillary devices. Ancillary devices are optional. However, national or international regulations may make some ancillary devices mandatory in relation to the utilization of the water meter.
The recommendations of this document apply to water meters, irrespective of technology, defined as integrating measuring instruments determining the volume of water flowing through them.
NOTE            Any national regulations apply in the country of use.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies and gives guidance on:
—   general requirements for storage of water outside consumers' buildings, including service reservoirs for potable water and reservoirs containing water not for human consumption at intake works or within treatment works, excluding those that are part of the treatment process;
—   design;
—   general requirements for product standards;
—   requirements for quality control and auditing, testing and commissioning;
—   operational requirements;
—   requirements for inspection, rehabilitation and repair.
The requirements of this document are applicable to:
—   design and construction of new reservoirs;
—   extension and modification of existing reservoirs;
—   significant rehabilitation of existing reservoirs.
This document does not apply to reservoirs formed by the building of dams or the use of lakes for water storage purposes.

  • Standard
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the general aspects of crosslinked polyethylene (PE-X) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption (domestic systems), and for heating systems, under design pressures and temperatures according to the class of application (see REF Table_tab_1 \r \h Table 1 08D0C9EA79F9BACE118C8200AA004BA90B02000000080000000C0000005400610062006C0065005F007400610062005F0031000000 ). This document also specifies the basis for the test parameters for the test methods referred to in the ISO 15875 series. This document covers a range of service conditions (application classes), design pressures and pipe dimension classes. The ISO 15875 series does not apply to values of design temperature (TD), maximum temperature (Tmax) and malfunction temperature (Tmal), as well as service times in excess of those defined in REF Table_tab_1 \r \h Table 1 08D0C9EA79F9BACE118C8200AA004BA90B02000000080000000C0000005400610062006C0065005F007400610062005F0031000000 .

  • Standard
    11 pages
    English language
    sale 15% off
  • Standard
    11 pages
    French language
    sale 15% off

This document specifies the characteristics of fittings for crosslinked polyethylene (PE-X) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption (domestic systems) and for heating systems under design pressures and temperatures according to the class of application (see ISO 15875-1:—, Table 1). This document also specifies the test parameters for the test methods referred to herein. This document is applicable to fittings made from PE-X or other plastics or non-plastics materials, which are intended to be connected to pipes conforming to ISO 15875-2 for hot and cold water installations, whereby the joints conform to the requirements of ISO 15875-5. This document is applicable to fittings of the following types: — mechanical fittings; — electrofusion fittings;

  • Standard
    26 pages
    English language
    sale 15% off
  • Standard
    26 pages
    French language
    sale 15% off

This document specifies the characteristics of the fitness for purpose of crosslinked polyethylene (PE-X) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water whether or not intended for human consumption (domestic systems), and for heating systems, under design pressures and temperatures appropriate to the class of application (see ISO 15875-1:2025, Table 1). This document also specifies the test parameters for the test methods referred to herein. This document is applicable to joints between pipes conforming to ISO 15875-2 and fittings made of plastics and non-plastics materials conforming to ISO 15875-3, for hot and cold water installations.

  • Standard
    8 pages
    English language
    sale 15% off
  • Standard
    8 pages
    French language
    sale 15% off

This document specifies the characteristics of pipes for crosslinked polyethylene (PE-X) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water whether or not intended for human consumption (domestic systems), and for heating systems, under design pressures and temperatures according to the class of application (see ISO 15875-1:2025, Table 1). This document also specifies the test parameters for the test methods referred to in this document. It is applicable to PE-X pipes with and without barrier layer. This document is applicable to PE-X pipes for hot and cold water installations, which are intended to be connected to fittings conforming to ISO 15875-3, whereby the joints conform to the requirements of ISO 15875-5.

  • Standard
    26 pages
    English language
    sale 15% off
  • Standard
    27 pages
    French language
    sale 15% off

This document applies to water meters used to meter the volume of cold potable water and hot water flowing through a fully charged, closed conduit. These water meters incorporate devices which indicate the integrated volume.
This document specifies criteria for the selection of single, combination and concentric water meters, associated fittings, installation, special requirements for meters, and the first operation of new or repaired meters to ensure accurate constant measurement and reliable reading of the meter.
In addition to meters based on mechanical principles, this document also applies to water meters based on electrical or electronic principles, and to water meters based on mechanical principles incorporating electronic devices, used to measure the volume of cold potable water and hot water. It also applies to electronic ancillary devices. Ancillary devices are optional. However, national or international regulations may make some ancillary devices mandatory in relation to the utilization of the water meter.
The recommendations of this document apply to water meters, irrespective of technology, defined as integrating measuring instruments determining the volume of water flowing through them.
NOTE            Any national regulations apply in the country of use.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document applies to water meters used to meter the volume of cold potable water and hot water flowing through a fully charged, closed conduit. These water meters incorporate devices which indicate the integrated volume. This document specifies criteria for the selection of single, combination and concentric water meters, associated fittings, installation, special requirements for meters, and the first operation of new or repaired meters to ensure accurate constant measurement and reliable reading of the meter. In addition to meters based on mechanical principles, this document also applies to water meters based on electrical or electronic principles, and to water meters based on mechanical principles incorporating electronic devices, used to measure the volume of cold potable water and hot water. It also applies to electronic ancillary devices. Ancillary devices are optional. However, national or international regulations may make some ancillary devices mandatory in relation to the utilization of the water meter. The recommendations of this document apply to water meters, irrespective of technology, defined as integrating measuring instruments determining the volume of water flowing through them. NOTE Any national regulations apply in the country of use.

  • Standard
    12 pages
    English language
    sale 15% off
  • Standard
    13 pages
    French language
    sale 15% off

IEC SRD 63301-2:2025 This part develops use cases based on user stories, which are to be arranged in database for analysis, so as to scope out standard requirements, specifically electro-technical standards for IEC and other Standard Development Organizations (SDOs) regarding water management.

  • Standardization document
    40 pages
    English language
    sale 15% off

This document specifies an analysing methodology for protecting potable water in potable water installations within and outside buildings but within premises from the risk of pollution by backflow of non-potable water and gives recommendations on the design, risk analysis, backflow prevention devices and their installation methods (see Figure 1 and Figure 2).
This methodology is also intended to be used outside premises for all water systems connected to a potable water distribution system up to and including the point of use (see Figure 3).
The product standards for the specific backflow prevention devices or arrangements are intended to be used in conjunction with this document. For the development of new devices or systems, this document is intended to be used as a reference to establish the necessary level of backflow protection.

  • Standard
    66 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies an analysing methodology for protecting potable water in potable water installations within and outside buildings but within premises from the risk of pollution by backflow of non-potable water and gives recommendations on the design, risk analysis, backflow prevention devices and their installation methods (see Figure 1 and Figure 2).
This methodology is also intended to be used outside premises for all water systems connected to a potable water distribution system up to and including the point of use (see Figure 3).
The product standards for the specific backflow prevention devices or arrangements are intended to be used in conjunction with this document. For the development of new devices or systems, this document is intended to be used as a reference to establish the necessary level of backflow protection.

  • Standard
    66 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to the type evaluation and initial verification testing of water meters for cold potable water and hot water as defined in ISO 4064-1:2024|OIML R 49‑1:2024. OIML Certificates of conformity can be issued for water meters under the scope of the OIML Certificate System, provided that this document, ISO 4064-1:2024|OIML R 49‑1:2024 and ISO 4064-3:2024|OIML R 49‑3:2024 are used in accordance with the rules of the system.
This document sets out details of the test programme, principles, equipment and procedures to be used for the type evaluation, and initial verification of a meter type.
The provisions of this document also apply to ancillary devices, if required by national regulations.
The provisions include requirements for testing the complete water meter and for testing the measurement transducer (including the flow or volume sensor) and the calculator (including the indicating device) of a water meter as separate units.

  • Standard
    114 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the metrological and technical requirements for water meters for cold potable water and hot water flowing through a fully charged, closed conduit. These water meters incorporate devices which indicate the accumulated volume.
In addition to water meters based on mechanical principles, this document applies to devices based on electrical or electronic principles, and mechanical principles incorporating electronic devices, used to measure the volume of cold potable water and hot water.
This document also applies to electronic ancillary devices. Ancillary devices are optional. However, it is possible for national or regional regulations to render some ancillary devices mandatory in relation to the utilization of water meters.
NOTE            Any national regulations apply in the country of use.

  • Standard
    58 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document applies primarily to copper alloy and stainless steel ball valves with dimensions DN 6 to DN 100, for installations in buildings for potable water supply up to PN16 and a maximum distribution temperature of 65 °C. Occasional excursions up to 90 °C are permitted for a period of 1 h maximum.
The ball valves are classified by their nominal pressure being either PN10 or PN16.
This document specifies:
-   the requirements of the materials and the design of ball valves;
-   the mechanical, hydraulic and acoustic requirements of ball valves;
-   the test methods to verify the requirements of ball valves;
-   the marking requirements of ball valves.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the metrological and technical requirements for water meters for cold potable water and hot water flowing through a fully charged, closed conduit. These water meters incorporate devices which indicate the accumulated volume.
In addition to water meters based on mechanical principles, this document applies to devices based on electrical or electronic principles, and mechanical principles incorporating electronic devices, used to measure the volume of cold potable water and hot water.
This document also applies to electronic ancillary devices. Ancillary devices are optional. However, it is possible for national or regional regulations to render some ancillary devices mandatory in relation to the utilization of water meters.
NOTE            Any national regulations apply in the country of use.

  • Standard
    58 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to the type evaluation and initial verification testing of water meters for cold potable water and hot water as defined in ISO 4064-1:2024|OIML R 49‑1:2024. OIML Certificates of conformity can be issued for water meters under the scope of the OIML Certificate System, provided that this document, ISO 4064-1:2024|OIML R 49‑1:2024 and ISO 4064-3:2024|OIML R 49‑3:2024 are used in accordance with the rules of the system.
This document sets out details of the test programme, principles, equipment and procedures to be used for the type evaluation, and initial verification of a meter type.
The provisions of this document also apply to ancillary devices, if required by national regulations.
The provisions include requirements for testing the complete water meter and for testing the measurement transducer (including the flow or volume sensor) and the calculator (including the indicating device) of a water meter as separate units.

  • Standard
    114 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document applies to water meters used to meter the volume of cold potable water and hot water flowing through a fully charged, closed conduit. These water meters incorporate devices which indicate the integrated volume.
This document specifies technical characteristics and pressure loss requirements for meters for cold potable water and hot water. It applies to water meters which can withstand:
a)       a maximum admissible pressure (MAP) equal to at least 1 MPa1) [0,6 MPa for meters for use with pipe nominal diameters (DNs) ≥500 mm];
b)       a maximum admissible temperature (MAT) for cold potable water meters of 30 °C;
c)        a MAT for hot water meters of up to 180 °C, depending on class.
In addition to meters based on mechanical principles, this document also applies to water meters based on electrical or electronic principles, and to water meters based on mechanical principles incorporating electronic devices, used to meter the volume flow of hot water and cold potable water. It also applies to electronic ancillary devices. As a rule ancillary devices are optional. However, national or international regulations may make some ancillary devices mandatory in relation to the utilization of the water meter.
1) 1 MPa = 10 bar (1 bar = 0,1 MPa =105 Pa; 1 MPa = 1 N/mm2).

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test report format to be used in conjunction with ISO 4064-1:2024|OIML R 49-1:2024 and ISO 4064-2:2024|OIML R 49-2:2024 for water meters for cold potable water and hot water.

  • Standard
    78 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test report format to be used in conjunction with ISO 4064-1:2024|OIML R 49-1:2024 and ISO 4064-2:2024|OIML R 49-2:2024 for water meters for cold potable water and hot water.

  • Standard
    78 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document applies to water meters used to meter the volume of cold potable water and hot water flowing through a fully charged, closed conduit. These water meters incorporate devices which indicate the integrated volume.
This document specifies technical characteristics and pressure loss requirements for meters for cold potable water and hot water. It applies to water meters which can withstand:
a)       a maximum admissible pressure (MAP) equal to at least 1 MPa1) [0,6 MPa for meters for use with pipe nominal diameters (DNs) ≥500 mm];
b)       a maximum admissible temperature (MAT) for cold potable water meters of 30 °C;
c)        a MAT for hot water meters of up to 180 °C, depending on class.
In addition to meters based on mechanical principles, this document also applies to water meters based on electrical or electronic principles, and to water meters based on mechanical principles incorporating electronic devices, used to meter the volume flow of hot water and cold potable water. It also applies to electronic ancillary devices. As a rule ancillary devices are optional. However, national or international regulations may make some ancillary devices mandatory in relation to the utilization of the water meter.
1) 1 MPa = 10 bar (1 bar = 0,1 MPa =105 Pa; 1 MPa = 1 N/mm2).

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies additional requirements to the product standards given in Clause 5 for valves and devices to prevent pollution by backflow of potable water with polymer parts and housings under internal pressure and without external loads intended for installations and equipment inside buildings conveying water for human consumption.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test report format to be used in conjunction with ISO 4064-1:2024|OIML R 49-1:2024 and ISO 4064-2:2024|OIML R 49-2:2024 for water meters for cold potable water and hot water.

  • Standard
    69 pages
    English language
    sale 15% off
  • Standard
    86 pages
    French language
    sale 15% off

This document specifies the metrological and technical requirements for water meters for cold potable water and hot water flowing through a fully charged, closed conduit. These water meters incorporate devices which indicate the accumulated volume. In addition to water meters based on mechanical principles, this document applies to devices based on electrical or electronic principles, and mechanical principles incorporating electronic devices, used to measure the volume of cold potable water and hot water. This document also applies to electronic ancillary devices. Ancillary devices are optional. However, it is possible for national or regional regulations to render some ancillary devices mandatory in relation to the utilization of water meters. NOTE Any national regulations apply in the country of use.

  • Standard
    46 pages
    English language
    sale 15% off
  • Standard
    49 pages
    French language
    sale 15% off

This document applies to water meters used to meter the volume of cold potable water and hot water flowing through a fully charged, closed conduit. These water meters incorporate devices which indicate the integrated volume. This document specifies technical characteristics and pressure loss requirements for meters for cold potable water and hot water. It applies to water meters which can withstand: a) a maximum admissible pressure (MAP) equal to at least 1 MPa1) [0,6 MPa for meters for use with pipe nominal diameters (DNs) ≥500 mm]; b) a maximum admissible temperature (MAT) for cold potable water meters of 30 °C; c) a MAT for hot water meters of up to 180 °C, depending on class. In addition to meters based on mechanical principles, this document also applies to water meters based on electrical or electronic principles, and to water meters based on mechanical principles incorporating electronic devices, used to meter the volume flow of hot water and cold potable water. It also applies to electronic ancillary devices. As a rule ancillary devices are optional. However, national or international regulations may make some ancillary devices mandatory in relation to the utilization of the water meter. 1) 1 MPa = 10 bar (1 bar = 0,1 MPa =105 Pa; 1 MPa = 1 N/mm2).

  • Standard
    28 pages
    English language
    sale 15% off
  • Standard
    28 pages
    French language
    sale 15% off
  • Standard
    28 pages
    French language
    sale 15% off

This document is applicable to the type evaluation and initial verification testing of water meters for cold potable water and hot water as defined in ISO 4064-1:2024|OIML R 49‑1:2024. OIML Certificates of conformity can be issued for water meters under the scope of the OIML Certificate System, provided that this document, ISO 4064-1:2024|OIML R 49‑1:2024 and ISO 4064-3:2024|OIML R 49‑3:2024 are used in accordance with the rules of the system. This document sets out details of the test programme, principles, equipment and procedures to be used for the type evaluation, and initial verification of a meter type. The provisions of this document also apply to ancillary devices, if required by national regulations. The provisions include requirements for testing the complete water meter and for testing the measurement transducer (including the flow or volume sensor) and the calculator (including the indicating device) of a water meter as separate units.

  • Standard
    97 pages
    English language
    sale 15% off
  • Standard
    102 pages
    French language
    sale 15% off

IEC SRD 63301-1:2024 provides an overview of water systems in smart cities, establishes a general approach for use case collection and analysis, and identifies major stakeholders and application areas for high-level analysis of water systems.
The construction of a smart city can create benefits for a society and its stakeholders. Water is a critical resource to support urban development and its sustainable use is recognized as a UN Sustainable Development Goal. Water infrastructure development, water management efficiency, water supply resilience, and the safe operation and use of water are important focal areas for smart cities.
This document focuses on water systems management, specifically water security whether directly from a natural source or via man-made infrastructure. Information and communications technologies (ICT) and electro-technologies can provide greater visibility and control, however their application does depend on the characteristics of individual water markets. Technology is not a panacea for resolving all issues and problems.
A gap exists in effective coordination and clear orientation and how industry and stakeholders are engaged within it.
Major stakeholders of water management and use include citizens, the water authority (government), and organizations (associations, business groups, utility companies). Each stakeholder has different and competing interests, market relationships and touch points to water system infrastructure, processes, operations, management and use.
Modelling these complex interactions into a systems architecture is a valuable exercise in understanding the issues, gaps and opportunities for sustainable water management.
This document focuses on use case collection and analysis to elicit requirements to support technical committees in preparing sustainable water management standards for cities and communities.

  • Standardization document
    45 pages
    English language
    sale 15% off

This document specifies additional requirements to the product standards given in Clause 5 for valves and devices to prevent pollution by backflow of potable water with polymer parts and housings under internal pressure and without external loads intended for installations and equipment inside buildings conveying water for human consumption.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies:
- general construction, performance and material requirements for Frost Resistant Taps for outdoor use (FRT), PN 10.
- the application in the potable water installation with a static pressure of maximum 1,0 MPa (10 bar) and a distribution temperature of maximum 25 °C (PWC).
FRT valves shall consist of the 3 areas shown in Figure 1.
The conditions of use are according to the following Table 1.
The requirements with regard to the potable water quality are specified in national regulations.

  • Corrigendum
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies:
- general construction, performance and material requirements for Frost Resistant Taps for outdoor use (FRT), PN 10.
- the application in the potable water installation with a static pressure of maximum 1,0 MPa (10 bar) and a distribution temperature of maximum 25 °C (PWC).
FRT valves shall consist of the 3 areas shown in Figure 1.
The conditions of use are according to the following Table 1.
The requirements with regard to the potable water quality are specified in national regulations.

  • Corrigendum
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of valves or valve bodies made from polyethylene (PE) for buried and above ground applications, intended for the conveyance of water for human consumption, raw water prior to treatment, drains and sewers under pressure, vacuum sewer systems, and water for other purposes, with the exception of industrial applications.
NOTE 1   For PE components intended for the conveyance of water for human consumption and raw water prior to treatment, attention is drawn to 6.4. Components manufactured for water for other purposes, drains and sewers, and vacuum systems are possibly not suitable for water supply for human consumption.
NOTE 2   Industrial application is covered by EN ISO 15494 [2].
The intended use includes sea outfalls, laid in water and pipes suspended below bridges.
It is applicable to isolating unidirectional and bi-directional valves with spigot ends or electrofusion sockets intended to be fused with PE pipes or fittings conforming to EN 12201-2 and EN 12201-3 respectively.
Valves made from materials other than PE, conforming to the relevant standards can be used in PE piping systems according to EN 12201, provided that they have PE connections for butt fusion or electrofusion ends, conforming to EN 12201-3, or material transition joints (e.g. flanged joints).
NOTE 3   For valves or valve bodies intended for drains and sewers, additional information is given in Clause 9.
It also specifies the test parameters for the test methods referred to in this document.
In conjunction with EN 12201-1, EN 12201 2, EN 12201 3 and EN 12201 5, this document is applicable to PE pipes, fittings and valves, their joints and joints with components of PE and other materials intended to be used under the following conditions:
a)   allowable operating pressure, PFA, up to 25 bar ;
b)   an operating temperature of 20 °C as a reference temperature.
NOTE 4   For applications operating at constant temperature greater than 20 °C and up to 50 °C, see EN 12201-1:2024, Annex A.
The EN 12201 series covers a range of allowable operating pressures and gives requirements concerning colours and additives.
NOTE 5   It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes.
This document covers valves for pipes with a nominal outside diameter dn ≤ 400 mm.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies materials and the general aspects of polyethylene (PE) pressure piping systems (mains and service pipes) for buried or above ground applications, intended for the conveyance of water for human consumption, raw water prior to treatment, drains and sewers under pressure, vacuum sewer systems, and water for other purposes, with the exception of industrial application.
NOTE 1   For PE components intended for the conveyance of water intended for human consumption and raw water prior to treatment attention is drawn to Clause 6 of this document. Components manufactured for water for other purposes, drains and sewers, and vacuum systems are possibly not suitable for water supply for human consumption.
NOTE 2   Industrial application is covered by EN ISO 15494 [6].
The intended use includes sea outfalls, laid in water and pipes suspended below bridges.
It also specifies the test parameters for the test methods referred to in this document.
In conjunction with EN 12201-2, EN 12201 3, EN 12201 4 and EN 12201 5, this document is applicable to PE pipes, fittings and valves, their joints and joints with components of PE and other materials intended to be used under the following conditions:
a)   allowable operating pressure, PFA, up to 25 bar  ;
b)   an operating temperature of 20 °C as a reference temperature.
NOTE 3   For applications operating at constant temperatures greater than 20 °C and up to and including 50 °C, see Annex A.
The EN 12201 series covers a range of allowable operating pressures and gives requirements concerning colours.
NOTE 4   It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of pipes made from polyethylene (PE) for buried and above ground applications, intended for the conveyance of water for human consumption, raw water prior to treatment, drains and sewers under pressure, vacuum sewer systems, and water for other purposes, with the exception of industrial application.
NOTE 1   For PE components intended for the conveyance of water for human consumption and raw water prior to treatment, attention is drawn to 6.3 of this document. Components manufactured for water for general purposes, drains and sewers, and vacuum sewer systems are possibly not suitable for water supply for human consumption.
NOTE 2   Industrial application is covered by EN ISO 15494 [4].
The intended uses include sea outfalls, laid in water and pipes suspended below bridges.
For use in contaminated soils special consideration is taken for pipes intended for the transport of water intended for human consumption or raw water prior to treatment.
NOTE 3   Pipes constructions including barrier layers are not covered by this document. ISO 21004 provides an alternative solution for use in contaminated soils [10].
It also specifies the test parameters for the test methods referred to in this document.
In conjunction with EN 12201-1, EN 12201-3, EN 12201-4 and EN 12201-5, this document is applicable to PE pipes, fitting and valves, their joints and joints with components of PE and other materials intended to be used under the following conditions:
a)   allowable operating pressure, PFA, up to 25 bar  ;
b)   an operating temperature of 20 °C as a reference temperature.
NOTE 4   For applications operating at constant temperatures greater than 20 °C and up to and including 50 °C, see EN 12201-1:2024, Annex A.
The EN 12201 series covers a range of allowable operating pressures and gives requirements concerning colours.
This document is applicable to three types of pipes:
—   PE pipes (outside diameter dn) including any identification stripes;
—   PE pipes with co-extruded layers on either or both the outside and/or inside of the pipe (total outside diameter dn) as specified in Annex B, where all PE layers have the same MRS rating;
—   PE pipes (outside diameter dn) with a peelable and contiguous thermoplastics additional layer on the outside of the pipe (“coated pipe”) as specified in Annex C.
NOTE 5   It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes.
NOTE 6   Assessment of the resistance to slow crack growth of the PE pipe compound used for the manufacture of products conforming to this document is required in accordance with EN 12201-1:2024, Table 2.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of fusion fittings made from polyethylene (PE) as well as of mechanical fittings for buried and above ground applications, intended for the conveyance of water for human consumption, raw water prior to treatment, drains and sewers under pressure, vacuum sewer systems, and water for other purposes, with the exception of industrial application.
NOTE 1   For PE components intended for the conveyance of water for human consumption and raw water prior to treatment, attention is drawn to subclause 6.6 of this document. Components manufactured for water for other purposes, drains and sewers, and vacuum sewer systems are possibly not suitable for water supply for human consumption.
NOTE 2   Industrial application is covered by EN ISO 15494 [4].
The intended uses include sea outfalls, laid in water and pipes suspended below bridges.
It also specifies the test parameters for the test methods referred to in this document.
In conjunction with EN 12201-1, EN 12201 2, EN 12201 4 and EN 12201 5, this document is applicable to PE pipes, fittings and valves, their joints and joints with components of PE and other materials intended to be used under the following conditions:
a)   allowable operating pressure, PFA, up to 25 bar  ;
b)   an operating temperature of 20 °C as a reference temperature.
NOTE 3   For applications operating at constant temperature greater than 20 °C and up to and including 50 °C, see EN 12201-1:2024, Annex A.
The EN 12201 series covers a range of allowable operating pressures and gives requirements concerning colours.
NOTE 4   It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes.
These fittings can be of the following types:
—   electrofusion socket fittings;
—   electrofusion saddle fittings;
—   spigot end fittings (for butt fusion using heated tools and electrofusion socket fusion);
—   socket fusion fittings (see Annex A);
—   mechanical fittings;
—   fabricated fittings (see Annex B).

  • Standard
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements of fitness for purpose of assembled polyethylene (PE) piping systems intended for the conveyance of water intended for human consumption, raw water prior to treatment, drains and sewers under pressure, vacuum sewer systems, and water for other purposes, with the exception of industrial application.
It specifies the requirements for electrofusion, socket fusion, butt fusion and mechanical joints.
It specifies the method of preparation of test piece joints, and the tests to be carried out on these joints for assessing the fitness for purpose of the system under normal and extreme conditions.
NOTE 1   For PE components intended for the conveyance of water for human consumption and raw water prior to treatment attention is drawn to the introduction of this document. Components manufactured for water for other purposes, drains and sewers, and vacuum systems, are possibly not suitable for water supply for human consumption.
NOTE 2   Industrial application is covered by EN ISO 15494 [2].
The intended use includes sea outfalls, laid in water and pipes suspended below bridges.
It also specifies the test parameters for the test methods referred to in this document.
This document is intended to only be used by the product manufacturer to assess the performance of components in accordance with EN 12201 2, EN 12201 3, or EN 12201 4 when joined together under normal and extreme conditions in accordance with this document. It is not intended for on-site testing of pipe systems.
In conjunction with EN 12201-1, EN 12201 2, EN 12201 3 and EN 12201 4 this document is applicable to PE pipes, fittings and valves, their joints and joints with components of PE and other materials intended to be used under the following conditions:
a)   allowable operating pressure, PFA, up to 25 bar ;
b)   an operating temperature of 20 °C as a reference temperature for design purposes.
NOTE 3   For applications operating at constant temperatures greater than 20 °C up to and including 50 °C, see EN 12201-1:2024, Annex A.
The EN 12201 series covers a range of allowable operating pressures and gives requirements concerning colours.
NOTE 4   It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of the fitness for purpose of oriented unplasticized poly(vinyl chloride) (PVC-O) solid wall piping intended to be used underground or above-ground where protected from direct sunlight, for water supply, buried drainage, sewerage, treated wastewater and irrigation under pressure. It also specifies the test parameters for the test methods referred to in this document. This document is not intended for on-site testing of pipe systems. In conjunction with ISO 16422-1, ISO 16422-2, ISO/TS 16422-3 and ISO 1452-3, this document is applicable to PVC-O pipes and PVC-O fittings, as well as to their joints and to joints with components of other plastics and non-plastics materials intended to be used for the following: a) water mains and services lines; b) conveyance of water for both outside and inside buildings; c) drainage, sewerage and treated wastewater under pressure; d) irrigation under pressure. This document is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C (cold water), intended for human consumption and for general purposes as well as for wastewater under pressure. This document is also applicable to components for the conveyance of water and wastewater up to and including 45 °C. For temperatures between 25 °C and 45 °C, see ISO 16422-2:2023, Figure C.1. The piping system according to this document is intended for the conveyance of cold water up to pressures of 25 bar[1] and especially in those applications where special performance requirements are needed, such as impact loads and pressure fluctuations, up to pressure of 25 bar. [1] 1 bar= 0,1 MPa = 105 Pa; 1 MPa= 1 N/mm2

  • Standard
    11 pages
    English language
    sale 15% off

This document specifies the characteristics of solid-wall pipes made of oriented unplasticized poly(vinyl chloride) (PVC-O) for piping systems intended to be used underground or above-ground (where protected from direct sunlight), for water supply, buried drainage, sewerage, treated wastewater and irrigation under pressure. It also specifies the test parameters for the test methods referred to in this document. In conjunction with ISO 16422-1 and ISO 16422-5, this document is applicable to oriented PVC-O pipes, with or without integral socket, intended to be used for the following: a) water mains and services lines; b) conveyance of water for both outside and inside buildings; c) drainage, sewerage and treated wastewater under pressure; d) irrigation under pressure. This document is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C (cold water), intended for human consumption and for general purposes as well as for wastewater under pressure. This document is also applicable to components for the conveyance of water and wastewater up to and including 45 °C. For temperatures between 25 °C and 45 °C, see Figure C.1. The piping system according to this document is intended for the conveyance of cold water up to pressures of 25 bar[1] and especially in those applications where special performance requirements are needed, such as impact loads and pressure fluctuations, up to pressure of 25 bar. [1] 1 bar = 0,1 MPa = 105 Pa; 1 MPa = 1 N/mm2

  • Standard
    25 pages
    English language
    sale 15% off

This document specifies the general characteristics of solid-wall pipes made of oriented unplasticized poly(vinyl chloride) (PVC-O) for piping systems intended to be used underground or above-ground (where protected from direct sunlight), for water supply, buried drainage, sewerage, treated waste water and irrigation under pressure. In conjunction with ISO 16422-2, ISO/TS 16422-3, ISO 16422-5 and ISO 1452-4, this document is applicable to PVC-O pipes and PVC-O fittings, as well as to valves, their joints and to joints with components of other plastics and non-plastics materials intended to be used for the following: a) water mains and services lines; b) conveyance of water for both outside and inside buildings; c) drainage, sewerage and treated wastewater under pressure; d) irrigation under pressure. This document is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C (cold water), intended for human consumption and for general purposes as well as for wastewater under pressure. This document is also applicable to components for the conveyance of water and wastewater up to and including 45 °C. For temperatures between 25 °C and 45 °C, see ISO 16422-2:2023, Figure C.1. The piping system according to this document is intended for the conveyance of cold water up to pressures of 25 bar[1] and especially in those applications where special performance requirements are needed, such as impact loads and pressure fluctuations, up to pressure of 25 bar. [1] 1 bar = 0,1 MPa = 105 Pa; 1 MPa = 1 N/mm2

  • Standard
    8 pages
    English language
    sale 15% off

This document specifies requirements for materials used in vulcanized rubber seals for the following: a) cold drinking-water supplies (up to 50 °C); b) drainage, sewerage, and rainwater systems (continuous flow up to 45 °C and intermittent flow up to 95 °C). The different designations of seals specified are defined according to their type, application, and requirements (see Table 5). General requirements for finished joint seals are also given; any additional requirements called for by the particular application are specified in the relevant product standards, taking into account that the performance of pipe joints is a function of the seal material properties, seal geometry, and pipe joint design. This document is intended to be used, where appropriate, with product standards which specify performance requirements for joints. This document is applicable to joint seals for all pipeline materials, including iron, steel, clay, fibre cement, concrete, reinforced concrete, plastics, and glass-reinforced plastics. It is applicable to elastomeric components of composite or non-composite seals. In the case of composite seals for materials of hardness ranges from 76 IRHD-M to 95 IRHD-M, the requirements for elongation at break, compression set, and stress relaxation apply only when the material is participating in the sealing function or in the long-term stability of the seal. Joint seals made with an enclosed void as part of their design are included in the scope of this document.

  • Standard
    14 pages
    English language
    sale 15% off

This document specifies:
- general construction, performance and material requirements for Frost Resistant Taps for outdoor use (FRT), PN 10.
- the application in the potable water installation with a static pressure of maximum 1,0 MPa (10 bar) and a distribution temperature of maximum 25 °C (PWC).
FRT valves shall consist of the 3 areas shown in Figure 1.
The conditions of use are according to the following Table 1.
The requirements with regard to the potable water quality are specified in national regulations.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day