CEN/TC 128 - Roof covering products for discontinuous laying and products for wall cladding
Standardization in the area of general and specific requirements and test methods for roof covering products for discontinuous laying and products for wall cladding, including anchor devices intended to prevent persons from falling and/or to arrest falls, used in and on buildings and civil engineering works
Izdelki za pokrivanje streh s prekrivajočim polaganjem in izdelki za oblaganje sten
Standardization in the area of general and specific requirements and test methods for roof covering products for discontinuous laying and products for wall cladding, including anchor devices intended to prevent persons from falling and/or to arrest falls, used in and on buildings and civil engineering works
General Information
This document specifies assessment of characteristics for anchor devices and safety hooks intended to be used with personal fall protection systems to prevent persons from falling and arrest falls, both permanently fixed on or into buildings and civil engineering works.
The safety hooks covered under this standard are also intended to for the attachment of mobile roof ladders or work platforms and have an opening of not less than 80 mm and not more than 150 mm, see Figure 2. The height h of the hook is at least 120 mm.
NOTE The personal fall protection systems are used according to EN 363:2018.
This standard also covers the fastening kits used to secure the anchor devices or safety hooks on or into the load bearing structure.
It specifies essential dimensions, materials and criteria to assess the performance of representative load bearing structures.
This standard describes the methods and criteria to assess the performance and durability of the following anchor kits:
- Kit A (Anchor kit incorporating a single anchor device);
- Kit B (Anchor kit incorporating a safety hook);
- Kit C (Anchor kit incorporating a horizontal wire anchor line);
- Kit D (Anchor kit incorporating a horizontal rail anchor line).
The kits described in this standard consist usually of several components. They are intended to be evaluated as a kit in its entirety.
This standard is not applicable to:
- Temporary anchor devices according to EN 795:2012;
- Facilities for roof access according to EN 516:2006;
- Permanently fixed ladders on roofs according to EN 12951:2004.
- Permanent anchor devices and safety hooks fixed with nails.
- Standard42 pagesEnglish languagesale 10% offe-Library read for1 day
This part of EN 508 specifies requirements for self-supporting products for roof covering, wall cladding, lining, liner tray and tile products for discontinuous laying made from stainless steel sheets with or without additional metallic and/or organic coatings. Sheets intended to be used with insulation and membranes are also covered.
This document establishes general characteristics, definitions, classifications and labelling for the products, together with requirements for the materials from which the products can be manufactured. It is intended to be used either by manufacturers to ensure that their products comply with the requirements or by purchasers to verify that the products comply before they are dispatched from the factory. It specifies the requirements for products which enable them to meet all normal service conditions.
This document applies to all discontinuously laid self-supporting external profiled sheets for roof covering, wall cladding, lining, liner trays and tile products with the exception of tiles with a surface area less than 1 m2 and produced by stamping. These profiled roof sheets are designed to keep wind, rain and snow out of the building and to transfer any resultant loads and infrequent maintenance loads to the structure.
This document does not cover products for structural purposes, i.e. it does cover products used in structural class III (according to EN 1993-1-3), it does not cover products used in constructions of structural classes I and II (according to EN 1993-1-3) intended to contribute to the global or partial stability of the building structure by providing racking resistance or resistance to permanent static loads (excluding self-weight of the metal sheet).
No requirements for supporting construction, design of roof or cladding, lining, tile system and execution of connections and flashings are included.
- Standard40 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements for eaves gutters made of unplasticized poly(vinyl chloride) (PVC-U), fittings and the system intended to be used for rainwater roof drainage.
It applies to:
- solid wall monolayer gutters;
- solid wall multilayer gutters;
- solid wall fittings.
The test parameters for the test methods are specified in the document.
Gutters covered by this document can be used in conjunction with fittings of acrylic materials provided these products meet the applicable requirements of this document.
NOTE 1 Products complying with this document can be used in conjunction with rainwater downpipes conforming to EN 12200-1 [1] and fixed with brackets complying with EN 1462 [2].
This document is applicable to PVC-U gutter systems of any shape with rubber seal or adhesive joints.
NOTE 2 It is the responsibility of the purchaser or specifier to make the appropriate selections from the size range and the design to take into account their particular requirements and any relevant national regulations and installation practices or codes.
NOTE 3 The term "rainwater" in this document is used also to encompass "surface water" (as defined in EN 752 [3]) run-off from buildings.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a test method to establish the uplift resistance of installed clay or concrete tiles for roofing, complying with the relevant product standard, EN 490 or EN 1304, which are unfixed or mechanically fixed to the substructure.
NOTE The test method has been developed for clay or concrete tiles for roofing, but can apply to other discontinuously laid small elements, such as: slates; fibre cement slates; stones; and, adapted accordingly, to photovoltaic and solar thermal panels.
The test method is applicable to mechanical fixings such as clips, hooks, screws and nails.
The method is not applicable to fixed tiles having fixing patterns with less than every third tile fixed.
The test method is not applicable to under and over tiles. Examples of these tiles are given in Annex F.
- Standard34 pagesEnglish languagesale 10% offe-Library read for1 day
The document establishes an agreed method for evaluation of pull through resistance (tension/compression for fasteners through the sheets), shear resistance, bending strength and bending modulus of elasticity and suggests an approved safety concept of fibre-cement flat sheets for internal and external wall and ceiling finishes based on the experiences obtained over the last number of years in different countries. The results are only applicable to the fibre-cement product and not to the complete fixing assembly.
NOTE 1 For design purposes of fibre-cement flat sheets in the final application, the failure modes pull-out and breaking of the fixing or substructure are not in the scope of this standard. They might become decisive and need to be tested or calculated according to the relevant design standards for fixings (e.g. EN 14592) or ETA and substructure (e.g. Eurocode 3 for steel, Eurocode 5 for wood and Eurocode 9 for aluminium substructures) and compared with the results for pull-through and shear resistance.
The results are also applicable for:
— Coated or uncoated sheets manufactured at the same production facility as the tested sheets provided that the sheets are of the same type, have at least the same declared class according to EN 12467:2012+A2:2018, Table 6 and at least the same nominal thickness.
— The test method can be applied to textured or non-textured fibre-cement flat sheets. The results of non-textured sheets are only applicable for textured sheets if the nominal minimum thickness of the textured sheet is at least the nominal thickness of the non-textured sheet.
— The same type of fixing head or washer assembly where applicable if the diameter of the fixing head or washer is 0 mm to 2 mm larger than in the test.
— The Shore A hardness of the sealing washer, where applicable, is ± 5 that of the washer used in the test, given that the washer thickness is at least as thick, the washer material at least as strong and the shape (dome or flat) of the washer equal to what has been tested.
NOTE 2
A) For pull-through resistance, if the diameter of the drilled hole through the fibre-cement sheet is 0 mm to 2 mm smaller or equal than in the test up to the diameter of the shank of the fastener, providing, during the test there is the required clearance hole around the shank of the fastener.
B) For shear resistance, if the diameter of the drilled hole is equal to what has been tested.
It applies only to products as delivered.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies test methods for pull through (tension/compression testing for fasteners through the sheets) and shear resistance of fibre-cement profiled sheets according to EN 494. The results are only applicable to the fibre-cement product and not to the complete fixing assembly.
It applies only to products as delivered.
The field of application for pull through resistance is defined in 7.6.
The field of application for shear resistance is defined in 8.6.
NOTE For design purposes of fibre-cement profiled sheets in the final application, the failure modes pull-out and breaking of the fixings or substructure are not in the scope of this standard. They might become decisive and need to be tested or calculated according to the relevant design standards for fixings (e.g. Eurocode 3 for steel, Eurocode 5 for wood and Eurocode 9 for aluminium substructures) and compared with the results for pull-through and shear resistance.
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
This part of EN 508 specifies requirements for self-supporting roofing, covering, wall cladding, lining, liner tray and tile products for discontinuous laying made from metallic coated steel sheet with or without additional organic coatings. Sheets intended to be used with insulation and membranes are also covered.
This document establishes general characteristics, definitions, classifications and labelling for the products, together with requirements for the materials from which the products can be manufactured. It is intended to be used either by manufacturers to ensure that their products comply with the requirements or by purchasers to verify that the products comply when purchased before they are dispatched from the factory. It specifies the requirements for products which enable them to meet all normal service conditions.
This document applies to all discontinuously laid self-supporting external profiled sheets for roofing covering, wall cladding, lining, and liner trays, with the exception of tiles with a surface area less than 1 m2 and produced by stamping. These profiled sheets are designed to keep wind, rain and snow out of the building and to transfer any resultant loads and infrequent maintenance loads to the structure.
This document does not cover products for structural purposes, i.e. it does cover products used in constructions of structural Class III (according to EN 1993-1-3), it does not cover products used in constructions of structural Classes I and II (according to EN 1993-1-3) intended to contribute to the global or partial stability of the building structure by providing racking resistance or resistance to permanent static loads (excluding self-weight of the metal sheet).
No requirements for supporting construction, design of roof, cladding, lining, tile system and execution of connections and flashings are included.
- Standard48 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies requirements for roofing and cladding products used for assembly into coverings for wall claddings, linings and pitched roofs, made from aluminium sheet with or without additional surface treatment (organic coating or anodising).
This document establishes general characteristics, definitions and labelling of the products, together with requirements for the materials from which the products can be manufactured. It is intended to be used either by manufacturers to ensure that their products comply with the requirements or by purchasers to verify that the products comply before they are despatched from the factory. It specifies the requirements for products which enable them to meet all normal service conditions. Products can be prefabricated or semi-formed products as well as strip, coil and sheet for on-site-formed applications (e.g. standing seam roofs).
This document applies to all discontinuously laid and fully supported roofing and cladding products made of aluminium sheets. No requirements for supporting construction, design of roof system and execution of connections and flashings are included.
This document does not apply to self-supporting aluminium sheets that are covered by EN 508-2.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
This part of EN 508 specifies requirements for self-supporting external profiled sheets for roof covering, wall cladding, lining and liner tray products for discontinuous laying made from aluminium sheet with or without surface treatment (additional organic coatings or anodising).
This document establishes general characteristics, definitions, classifications and labelling for the products, together with requirements for the materials from which the products can be manufactured. It is intended to be used either by manufacturers to ensure that their products comply with the requirements or by purchasers to verify that the products comply before they are made available on the market before being despatched from the factory. It specifies the requirements for products which enable them to meet all normal service conditions.
This document applies to all discontinuously laid self-supporting external profiled sheets for roof covering, wall cladding, lining and liner trays with the exception of tiles with a surface area less than 1 m2 and produced by stamping. These profiled roof sheets are designed to keep wind, rain and snow out of the building, and to transfer any resultant loads and infrequent maintenance loads to the structure.
This document does not cover products for structural purposes, i.e. it does cover products used in structural class III (according to EN 1999-1-4), it does not cover products used in constructions of Structural Classes I and II (according to EN 1999-1-4) intended to contribute to the global or partial stability of the building structure by providing racking resistance or resistance of permanent static loads (excluding self-weight of the metal sheet).
No requirements for supporting construction, design of roof system and execution of connections and flashings are included.
- Standard39 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the technical requirements and establishes methods of control and test as well as acceptance conditions for fibre-cement slates and their fibre-cement fittings for one or more of the following uses:
- roofing;
- internal wall finishes;
- external wall and ceiling finishes.
This European Standard applies to fibre-cement slates with a height dimension h (see Clause 4) not exceeding 850 mm for overlapping assembly. For the purpose of this European Standard, fibre-cement slates have been classified according to their bending moment.
This European Standard covers fibre-cement slates reinforced with fibres of different types as specified in 5.1.1.
This European Standard does not include calculations with regard to works, design requirements, installation techniques, wind uplift or rain proofing of the installed products.
- Standard49 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the technical requirements and establishes methods of inspection and test as well as acceptance conditions for fibre-cement flat sheets, siding shingles and planks (referred to as sheets later in this document) for one or more of the following uses:
- internal wall and ceiling finishes;
- external wall and ceiling finishes.
Products covered by this European Standard can be used for other purposes provided they comply with the relevant application standard, e.g. rigid underlays.
This European Standard covers sheets reinforced with fibres of different types as specified in 5.1.1.
This European Standard does not cover sheets for fire protection purposes.
This European Standard does not include calculations with regard to works, design requirements, installation techniques, wind uplift or rain proofing of the installed sheets.
- Standard57 pagesEnglish languagesale 10% offe-Library read for1 day
This Technical Report provides guidance on the principles and requirements of structural design for the safety and serviceability of the structural connection between solar energy panels (thermal or photovoltaic) that are mounted on flat or pitched roofs.
This Technical Report does not include requirements for:
- weather tightness of the roof, solar panels and connections;
- electrical, thermal or mechanical characteristics of the solar panels;
- precautions against fire of the installation.
- Technical report73 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for concrete roofing tiles and fittings for pitched roof coverings and wall cladding and lining.
Concrete roofing tiles and fittings may incorporate surface coatings and glued concrete components.
NOTE 1 Information on surface characteristics is given in Annex A.
NOTE 2 Information on the performance of roof and wall assemblies is given in Annex B.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the technical requirements and establishes methods of control and test as well as acceptance conditions for fibre-cement profiled sheets and their fibre-cement fittings for one or more of the following uses:
- roofing;
- internal wall finishes;
- external wall and ceiling finishes.
For the purpose of this European Standard, fibre-cement profiled sheets are classified according to their height of corrugation and their mechanical characteristics.
This European Standard covers fibre-cement profiled sheets reinforced with fibres of different type as specified in 5.1.1, with and without factory applied coating.
This European Standard does not include calculations with regard to works, design requirements, installation techniques, wind uplift or rain proofing of the installed sheets.
NOTE Some of these requirements can be applied, after agreement, to curved sheets for specific applications.
- Standard71 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements for light transmitting flat multiwall polycarbonate (PC) sheets for internal and external use in walls, roofs and ceilings.
This European Standard applies to light transmitting flat extruded multiwall PC sheets with or without functional layers (e.g. coating, co-extruded layer) made from PC-based or other materials, without filling materials.
It also specifies the test methods needed for the evaluation of conformity and marking of the sheets.
- Standard69 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements for light transmitting single skin profiled plastics sheets for internal and external walls, roofs and ceilings. It is applicable to single skin sheets which are used as a single layer or when assembled to form a multiple layer construction.
It also specifies the test methods and provides for the evaluation of conformity and marking of the sheets.
- Standard58 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for rooflights made of plastic materials (e.g. GF-UP, PC, PMMA, PVC) and rooflights with upstands made of e.g. GF-UP, PVC, steel, aluminium or wood for installation in roofs. These rooflights serve the purpose of introducing daylight.
This European Standard applies to rooflights with a rectangular or circular ground plan (see Figures 1 and 2), with an opening span (width) or diameter not larger than 2,5 m and an opening length not larger than 3,0 m in roof pitches up to 25°. This document does not cover rooflights which contribute to the load-bearing or stiffness of the roof itself.
This European Standard applies to rooflights and rooflights with upstand, where a single manufacturer provides all components of the rooflight with upstand, which are bought in a single purchase.
This European Standard applies to rooflights with one or several translucent parts.
Rooflights may be opened by means of opening devices in one or more parts for ventilation.
The possible additional functions of day to day ventilation, smoke and heat ventilation e.g. in case of fire in accordance with EN 12101 2, roof access, and/ or slinging point e.g. in accordance with EN 795 are outside the scope of this document.
This European Standard does not include calculations with regard to construction, design requirements and installation techniques.
NOTE Guidelines for safety, application, use and maintenance of individual rooflights are presented in Annex A.
- Standard79 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for factory made, self-supporting, double skin metal faced insulating sandwich panels, which are intended for discontinuous laying in the following applications:
a) roofs and roof cladding;
b) external walls and wall cladding;
c) walls (including partitions) and ceilings within the building envelope.
The insulating core materials covered by this European Standard are rigid polyurethane, expanded polystyrene, extruded polystyrene foam, phenolic foam, cellular glass and mineral wool.
NOTE Polyurethane (PUR) includes polyisocyanurate (PIR).
Panels with edge details that utilise different materials from the main insulating core are included in this European Standard.
Panels used in cold store applications are included in this European Standard. Panels, put on the market as a component of a cold storage room, building and/or building envelope kit are covered by ETA-Guideline 021 “Cold storage premises kits”.
This European Standard does not cover the following:
i. sandwich panels with a declared thermal conductivity for the insulating core greater than 0,06 W/m•K at 10 °C;
ii. products consisting of two or more clearly defined layers of different insulating core materials (multi-layered);
iii. panels with perforated facing(s);
iv. curved panels.
- Standard175 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for slate and carbonate slate for discontinuous roofing and external cladding, as defined in 3.1, and 3.2, used for assembly into discontinuous roofing and external cladding.
For the purposes of this European Standard, slates and carbonate slates have been classified.
This European Standard does not apply to products for roofing or external cladding made from the following:
a) stone other than those defined in 3.1 and 3.2;
b) concrete;
c) polymeric materials;
d) fibre reinforced cement;
e) metal;
f) clay.
This European Standard is not applicable to roofing and cladding slates used internally.
This European Standard is not applicable to bonded cladding (cladding fixed with adhesives) and cladding fixed with dowels and cramps.
NOTE 1 Requirements for internal wall lining slate are specified in EN 1469.
This document does not include requirements for appearance.
NOTE 2 Some general guidance for appearance is given in Annex A.
This European Standard does not include installation rules for slates.
NOTE 3 References to national recommendations on methods of construction for slate roofs are given in Annex C.
NOTE 4 Where the term "slate" is used in this document it means slate and carbonate slate unless otherwise indicated.
- Standard47 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements for light transmitting flat solid polycarbonate (PC) sheets for internal and external use in walls, roofs and ceilings.
This European Standard applies to light transmitting flat extruded solid PC sheets of minimum thickness 2 mm, without or with uniform functional layers (e.g. coating, co-extruded layer) made from PC-based or other materials.
It also specifies the test methods needed for the evaluation of conformity and marking of the sheets.
- Standard45 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for clay roofing tiles and fittings for pitched roof coverings and wall cladding and lining.
It applies to all tiles and fittings as defined in Clause 3.
Clay roofing tiles and clay fittings which conform to this European Standard are suitable for use as roof coverings, vertical wall cladding and lining.
This European Standard defines the minimum requirements for a product which if satisfactory at the time of delivery will ensure that the product is able to perform its function in relation to the performance levels declared for it, whilst subjected to the changes that occur in such materials during normal conditions of use.
The results obtained according to the European Standard apply to products at the time they are offered for sale.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the test method for the determination of frost resistance of clay roofing tiles and fittings.
The test method is applicable in all CEN member countries in accordance with the required performance level of each member state.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the terminology, requirements and test methods for metal coil, strip, and flat sheets and factory made pieces intended for fully supported applications in roofing and wall cladding or lining. It does not apply to products manufactured on site.
This European Standard covers fully-supported aluminium, copper, lead, steel, stainless steel and zinc products with or without coatings, e.g. metallic, organic, inorganic or multi-layer (see Annex A).
This European Standard also includes rules for marking, labelling and evaluation of conformity.
Requirements concerning acoustical and insulation properties are not considered in this European Standard.
This European Standard does not include calculation or design requirements with regards to the works, installation techniques or the performance of the installed products.
- Standard28 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the properties, performance and methods of test of the finished bitumen shingles prior to them being laid on the roof.
It also includes rules for marking, labelling and provides a clause for evaluation of conformity.
This European Standard does not include design requirements, installation techniques and roof system performance.
This European Standard applies to bitumen shingles where the watertightness of the system is ensured by overlapping, by different adhesive systems or a combination of these, according to manufacturer’s installation instructions, intended to be laid as covering for pitched roofs and/or wall cladding.
This European Standard applies only to bitumen shingles with a mineral reinforcement, synthetic reinforcement or a mixture of the two.
In case of multilayer shingles each layer need to have the same type of reinforcement and same type of coating (ref. to Clause 8).
- Standard37 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for roofing products used for assembly into coverings for pitched roofs, made from metallic coated steel sheet with or without additional organic coatings.
The European Standard establishes general characteristics, definitions and labelling for the products, together with requirements for the materials from which the products can be manufactured. It is intended to be used either by manufacturers to ensure that their products comply with the requirements or by purchasers to verify that the products comply before they are despatched from the factory. It specifies the requirements for products which enable them to meet all normal service conditions. Products can be prefabricated or semiformed products as well as strip, coil and sheet for on-site-formed applications (e.g. standing-seam and clip fixroofs).
The European Standard applies to all discontinuously laid and fully supported roofing products made of steel sheets. No requirements for supporting construction, design of roof system and execution of connections and flashings are included.
NOTE The European Standard deals partly with flat products, partly with formed (prefabricated) products. Requirements for preformed self-supporting products are given in EN 508-1.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for roofing products used for assembly into coverings for pitched roofs, made from stainless steel, terne coated, tin coated or organic coated stainless steel sheet.
The European Standard establishes general characteristics, definitions and labelling for the products, together with requirements for the materials from which the products can be manufactured. It is intended to be used either by manufacturers to ensure that their products comply with the requirements or by purchasers to verify that the products comply before they are despatched from the factory. It specifies the requirements for products which enable them to meet all normal service conditions. Products can be prefabricated or semiformed products as well as strip, coil and sheet for on-site-formed applications (e.g. standing seam roofs, roll cap).
The European Standard applies to all discontinuously laid and fully supported roofing products made of stainless steel sheet. No requirements for application (e.g. methods of fixing, supporting construction, design of roof system, execution of connections and flashings) are included.
NOTE The standard deals partly with flat products, partly with formed (prefabricated) products. Requirements for preformed self-supporting roofing products are given in EN 508-3.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
This European standard specifies the methods for determining the geometric characteristics of clay tiles as defined in EN 1304, Clay roofing tiles and fittings Product definitions and specifications.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies test methods for concrete roofing tiles and fittings conforming to EN 490, for assembly into pitched roof covering or external wall cladding or internal wall lining cladding.
- Standard27 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies test methods for slate and carbonate slate for roofing and wall cladding. It is applicable to natural roofing products as defined in EN 12326-1 used for assembly into discontinuous roofs and external wall cladding.
NOTE Where the term "slate" is used in this document it means slate and carbonate slate unless otherwise indicated.
- Standard46 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the technical properties and establishes the test and inspection methods for finished corrugated bitumen sheets on leaving the factory. It also provides for the evaluation of conformity of products with the requirements of this standard.
- Standard40 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for self-supporting roofing products for discontinuous laying made from copper or zinc-copper-titanium alloy sheet with or without additional organic coatings.
The standard establishes general characteristics, definitions and labelling for the products, together with requirements for the materials from which the products can be manufactured. It is intended to be used either by manufacturers to ensure that their products comply with the requirements or by purchasers to verify that the products comply before they are despatched from the factory. It specifies the requirements for products which enable them to meet all normal service conditions.
The standard applies to all discontinuously laid self-supporting external profiled sheets for roofing with the exception of tiles with a surface area less than 1 m2 and produced by stamping. These profiled roof sheets are designed to keep wind, rain and snow out of the building and to transfer any resultant loads and infrequent maintenance loads to the structure.
No requirements for supporting construction, design of roof system and execution of connections and flashings are included.
- Standard35 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the technical requirements for factory made flat or profiled sheets (wood-based, fibre cement flat sheets or corrugated bituminous sheets or other materials which can be characterised as one of these materials) that are used as underlays in pitched roof constructions with discontinuously laid coverings (e.g. tiles, slates). This European Standard also establishes methods of inspection and testing as well as criteria for evaluation of conformity.
This European Standard does not include rigid underlays which have a stiffening function or a load bearing function.
- Standard24 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for continuous rooflights made of plastic materials (e.g.
GF-UP, PC, PMMA, PVC) with or without bearing profiles to be used with upstands made of e.g. GF-UP, PVC, steel, aluminium, wood or concrete, for laying in roofs, which serve the purpose of lighting by means of daylight and, possibly, of ventilating interior spaces by means of opening devices.
This European Standard applies to continuous rooflights without upstand and to continuous rooflights, where a single manufacturer provides all components of the rooflight with upstand, which are bought in a single purchase. Products covered by this European Standard may be supplied as continuous rooflights with and without upstand and rooflights intended to be used with an upstand, for which the upstand is specified, but not supplied.
It applies to continuous rooflights when mounted with an inclination in the longitudinal direction not more than 10° to the horizontal and not more than 10° in the transversal direction (see Figure 1):
a) with bearing profiles:
symmetrical, angled, curved (see Figure 2) or flat (see Figure 3);
constructed with bearing profiles parallel to the span and with a rectangular ground plan;
b) without bearing profiles:
symmetrical, angled or curved with an angle not more than 45° (measured to the horizontal at the line of fixing, see Figure 4);
constructed with a span (width) lower than or equal 2,5 m and with a rectangular ground plan.
This European Standard applies to continuous rooflights, including barrel vault rooflights, with a rectangular ground plan of plastic glazing laying in roofs having, in addition a minimum distance of b/3
(b = effective span of rooflights, corresponding to the light opening). The upstands may be self-supporting or non self-supporting.
The design of the upstand is not part of this European Standard. Upstands can be prefabricated or site fabricated. Prefabricated upstands are to be considered as p
- Standard56 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a soft body impact test method for fibre-cement profiled sheets for roofing.
This European Standard applies to fibre-cement profiled sheets conforming to EN 494 and of length greater than or equal to 1,04 m.
It applies only to products as delivered.
NOTE This European Standard can be applied, after agreement between manufacturer and purchaser, to curved sheets.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the terminology, requirements and test methods for factory made self-supporting metal sheets and tiles (for non-structural applications) delivered in the form of manufactured pieces for roofing and wall cladding and lining.
This standard also covers ceiling (including internal metal sheet) and soffit applications and cassettes (see Figure 1).
This standard covers self-supporting copper, zinc, steel, aluminium and stainless steel sheet with or without coatings, e.g. metallic, organic, inorganic or multi-layer (see Annex A). A moisture retaining layer may be present on the reverse side of the product.
This standard also includes rules for marking, labelling and evaluation of conformity.
This standard does not cover products for structural purposes, i.e. it does not cover products intended to contribute to the global or partial stability of the building structure by providing racking resistance or resistance to permanent static loads (excluding self-weight of the metal sheet).
Requirements concerning acoustical and thermal insulation properties are not considered in this standard.
This standard does not include calculation or design requirements with regards to the works, installation techniques or the performance of the installed products.
- Standard41 pagesEnglish languagesale 10% offe-Library read for1 day
This document applies to roof safety (building products) situated on the surface of pitched roofs and permanently fixed to the load-bearing roof construction. They are intended for the attachment of slaters’ ladders, for supporting working platforms and as anchorage points to which personal protective equipment against falls or for restraint are attached.
It specifies essential dimensions, materials to be used, requirements with respect to the load-bearing capacity, of the roof safety hooks fastened to the roof construction including their fastening system and the extent of testing.
This document does not apply to installations which are used exclusively as anchorage points to which personal protective equipment against falls or for restraint are attached (see EN 795).
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
This document applies to installations for roof access (building products) permanently fixed to the load-bearing construction of pitched roofs, to stand or to walk on during inspection, maintenance and repair of facilities on the roof.
It specifies essential dimensions, materials to be used, requirements with respect to the load-bearing capacity of the installation for roof access fastened to the roof construction including their fastening system, and the extent of testing.
This document does not apply to permanently fixed ladders on pitched roofs.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard describes two test methods for testing the impermeability to water of clay roof tiles and fittings which can be considered as equivalent.
NOTE The methods are not applicable to all fittings, because of their different shapes.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This document applies to permanently fixed ladders made of metal which are permanently installed on the load-bearing construction of pitched roofs and which may be stepped or walked on for purposes of inspection, maintenance and repair of equipment installed above the roof surface.
This document specifies essential dimensions, materials to be used, requirements with respect to the load-bearing capacity, and the extent of testing.
This document does not cover walkways, single treads, single steps or roof ladders that are not permanently fixed nor does it cover fire escape ladders.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies requirements for eaves gutters and rainwater down-pipes made from metal sheet. It establishes the general characteristics, designation system, classification, marking and quality requirements for the products.
The document applies to eaves gutters and external rainwater down-pipes that are supported by metal brackets and used to drain away rainwater. The shape and dimensions of a gutter are defined by the quantity of water to be drained away from the roof to the down-pipes and by architectural design requirements.
The document specifies the requirements for gutters and rainwater down-pipes which enable these products to meet all usual service conditions such as catching and draining away rainwater, melted snow or ice water from a building to a drainage system or a sewer outside the building.
Requirements for fixings, supporting construction, flashings or the method of making joints between the different components are not included in this document.
This document does not specify requirements for tolerances on dimensions for eaves gutters handmade on site.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements for rafter and fascia board brackets intended to support eaves gutters conforming to EN 607 or EN 612.
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for roofing products used for assembly into coverings for pitched roofs, made from copper sheet. The standard establishes general characteristics, definitions, and labelling for the products, together with requirements for the materials from which the products can be manufactured. It is intended to be used either by manufacturers to ensure that their products comply with the requirements or by purchasers to verify that the products comply before they are despatched from the factory.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
This EN specifies requirements for roofing products used for assembly into coverings for pitched roofs, made from Zinc Copper Titanium alloy sheet with or without additional organic coatings. This standard establishes the general characteristics, definitions, classifications, labelling and quality control for the products. Products can be prefabricated or semiformed products (eg. interlocking tile, slates, flashings...) as well as strip, coil sheet for on-site-formed applications (eg. standing seam roofs, roll cap...).
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard describes the test method used to evaluate the flexural strength of clay roofing tiles as defined in the standard EN YY - 'Clay roofing tiles - Product definitions and specifications'.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies test methods for slate, carbonate slate, schist and schistose stone for discontinuous roofing and external cladding, as defined in 3.1, 3.2, and 3.3 of EN 12326-1:2014 and 3.1 of prEN 12326-3:2021, used for assembly into discontinuous roofs and external wall cladding. In this sense, when the test describes a slate, it could also be considered as carbonate slate.
- Draft47 pagesEnglish languagesale 10% offe-Library read for1 day
This document establishes requirements for factory-made structural double skin metal faced insulating panels, intended for installation as elements with interlocking or overlapping longitudinal joints in the following applications:
a) roofs (also for refurbishment);
b) external walls and wall cladding (e.g. on brick walls for refurbishment or sandwich panels on liner trays);
c) walls (including partitions) and ceilings within the building envelope.
It is essential that structural double skin metal faced insulating sandwich panels according to this document (FprEN 14509-2) fulfil the requirements of EN 14509.
This document (FprEN 14509-2) gives the basic rule for use of structural sandwich panels for structural applications including fixing of panels. The clarification of which application is structural needs to be given by national provisions. The stabilization parameters needed to contribute to stabilization of individual structural elements (supporting structure) as defined as structural class II according to EN 1993-1-3 are included.
The insulating core materials covered by this document are rigid polyurethane, expanded polystyrene, extruded polystyrene foam, phenolic foam, cellular glass and mineral wool. For the stabilization purposes only, the following insulation core materials are covered rigid polyurethane, mineral wool, extruded polystyrene foam and expanded polystyrene foam.
NOTE Polyurethane (PUR) includes polyisocyanurate (PIR).
Due to durability performance reasons, only coated face material of steel faces is used (both organic and metallic coating). Uncoated steel is not used as steel face material. Uncoated stainless steel, aluminium and copper can be used in visible faces of sandwich panels.
Panels with edge details that utilize different materials from the main insulating core are included in this document if there is no influence on mechanical performance of the panel.
Panels used in cold store applications are included in this document. Panels, put on the market as a component of a cold storage room, building and/or building envelope kit are excluded.
This document does not cover the following:
- sandwich panels with a declared thermal conductivity for the insulating core greater than defined in the relevant harmonized European Standards for insulation materials;
- products consisting of two or more clearly defined layers of different insulating core materials (multi-layered);
- curved panels;
- perforated panels;
- fixings under permanent tension load for ceilings;
- special type of fastening such as ‘T’ support for ceiling, threaded rods with clamps for wall, omega and clamps for wall and ceiling, injected joint with flashing and threaded rods for wall and ceiling;
- fasteners.
- Draft33 pagesEnglish languagesale 10% offe-Library read for1 day
This part of EN 508 specifies requirements for self-supporting products for roof covering, wall cladding, lining, liner tray and tile products for discontinuous laying made from stainless steel sheets with or without additional metallic and/or organic coatings. Sheets intended to be used with insulation and membranes are also covered.
This document establishes general characteristics, definitions, classifications and labelling for the products, together with requirements for the materials from which the products can be manufactured. It is intended to be used either by manufacturers to ensure that their products comply with the requirements or by purchasers to verify that the products comply before they are dispatched from the factory. It specifies the requirements for products which enable them to meet all normal service conditions.
This document applies to all discontinuously laid self-supporting external profiled sheets for roof covering, wall cladding, lining, liner trays and tile products with the exception of tiles with a surface area less than 1 m2 and produced by stamping. These profiled roof sheets are designed to keep wind, rain and snow out of the building and to transfer any resultant loads and infrequent maintenance loads to the structure.
This document does not cover products for structural purposes, i.e. it does cover products used in structural class III (according to EN 1993-1-3), it does not cover products used in constructions of structural classes I and II (according to EN 1993-1-3) intended to contribute to the global or partial stability of the building structure by providing racking resistance or resistance to permanent static loads (excluding self-weight of the metal sheet).
No requirements for supporting construction, design of roof or cladding, lining, tile system and execution of connections and flashings are included.
- Draft4 pagesEnglish languagesale 10% offe-Library read for1 day
This European standard specifies the performance requirements and corresponding test methods for roofing slate products of schist and schistose stone types as defined in 3.2 and 3.3 and uses for assembly into discontinuous roofing.
This European standard provides also for the evaluation of conformity and for marking of the roofing slate products.
This European standard covers als characteristics that are of importance to the trade.
This European standard does not cover roofing slate and carboante slate, for mhich EN 12326-1 and EN 12326-2 applies. It does not cover treated roofing slates, for which prEN 12326-4 applies.
This European Standard is not apllicable to bonded cladding (cladding fixed with adhesives) and cladding fixed with dowels and cramps. In these cases EN 1469 applies.
The performance of a roof or wall constructed with these products depends not only on the properties of the product as required by this document, but also on the design, construction and performance of the roof or wall as a whole in relation to the environment and conditions in use. This standard does not cover installation or construction specific requirements.
- Draft31 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies test methods needed for determination of mechanical strength, building physical behaviour and durability of factory-made double skin metal faced insulating sandwich panels (hereafter sandwich panels) for use in elements for both self-supporting and structural applications in roofs, in external and internal walls (including partitions) and in ceilings in buildings as well as those in cold store applications.
- Draft112 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies design methods for combination of actions and spans for factory made double skin metal faced insulating sandwich panels (hereafter sandwich panels). The sandwich panels are for use in elements for both self-supporting and structural applications in roofs, in external and internal walls (including partitions) and in ceilings in buildings as well as those in cold store applications.
NOTE The description of self-supporting sandwich panels is given in prEN 14509-1:2020, Clause 1 and for structural sandwich panels in prEN 14509-2:2020, Clause 1.
- Draft30 pagesEnglish languagesale 10% offe-Library read for1 day