This document specifies the requirements and classification for assessing the explosive resistance of windows, doors, shutters as well as curtain walling elements, complete with their frames, infills and fixings, for use in both internal and external locations in buildings, when submitted to an arena test in accordance with EN 13124-2:2025. This document gives no information on the explosion resistance capacity of the wall or other surrounding structure.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements and classification for assessing the explosive resistance of windows, doors, shutters as well as curtain walling elements, complete with their frames, infills and fixings, for use in both internal and external locations in buildings, when submitted to a shock tube test in accordance with EN 13124-1:2025. This document gives no information on the explosion resistance capacity of the wall or other surrounding structure.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines a test method to permit a classification according to EN 13123-2:2025 for explosion resistance of windows, doors, shutters as well as curtain walling elements, complete with their frames, infills and fixings. This document gives no information on the ability of the surrounding wall or building structure to resist the direct or transmitted forces.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines a test method to permit a classification according to EN 13123-1:2025 for explosion resistance of windows, doors, shutters as well as curtain walling elements, complete with their frames, infills and fixings. This document gives no information on the ability of the surrounding wall or building structure to resist the direct or transmitted forces.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements and classification for assessing the explosive resistance of windows, doors, shutters as well as curtain walling elements, complete with their frames, infills and fixings, for use in both internal and external locations in buildings, when submitted to a shock tube test in accordance with EN 13124-1:2025. This document gives no information on the explosion resistance capacity of the wall or other surrounding structure.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements and classification for assessing the explosive resistance of windows, doors, shutters as well as curtain walling elements, complete with their frames, infills and fixings, for use in both internal and external locations in buildings, when submitted to an arena test in accordance with FprEN 13124-2:2025. This document gives no information on the explosion resistance capacity of the wall or other surrounding structure.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines a test method to permit a classification according to EN 13123-1:2025 for explosion resistance of windows, doors, shutters as well as curtain walling elements, complete with their frames, infills and fixings. This document gives no information on the ability of the surrounding wall or building structure to resist the direct or transmitted forces.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines a test method to permit a classification according to EN 13123-2:2025 for explosion resistance of windows, doors, shutters as well as curtain walling elements, complete with their frames, infills and fixings. This document gives no information on the ability of the surrounding wall or building structure to resist the direct or transmitted forces.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides complementary product category rules (c-PCR) for Type III environmental declarations for windows and pedestrian doorsets as defined in EN 14351-1 and EN 14351-2. Windows and pedestrian doorsets additionally providing fire resistance and/or smoke control characteristics according to EN 16034 are also covered by this document.
NOTE 1   Windows that incorporate shutters and/or shutter boxes and/or blinds are in scope of this
c-PCR. For any connected electrical devices (e.g. motors, sensors) - see 6.3.5.2.
NOTE 2   For wood and wood-based products for use in construction, see EN 16485.
NOTE 3   For building hardware, see EN 17610.
This document complements the core rules for the product category of construction products as defined in EN 15804:2012+A2:2019. This document is to be used in conjunction with EN 15804:2012+A2:2019, not replace it.
NOTE 4   The assessment of social and economic performances at product level is not covered by this document.
The core PCR:
-   defines the parameters to be declared and the way in which they are collated and reported;
-   describes which stages of a product’s life cycle are considered in the EPD and which processes are to be included in the life cycle stages;
-   defines rules for the development of scenarios;
-   includes the rules for calculating the Life Cycle Inventory and the Life Cycle Impact Assessment underlying the EPD, including the specification of the data quality to be applied;
-   includes the rules for reporting the predetermined, environmental and health information that is not covered by Life Cycle Assessment (LCA) for the product, construction process(es) and construction service(s), as relevant;
-   defines the conditions under which construction products can be compared based on the information provided by EPD.
For the EPD of construction services the same rules and requirements apply as for the EPD of construction products.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to hinged and pivoted doors, doorsets and door assemblies with glass based leaves. Throughout this document the term “doorset” will be used to cover doors, doorsets and door assemblies. It prescribes the methodology for extending the application of test results obtained from fire resistance test(s) conducted in accordance with EN 1634-1 and/or EN 1634-3 and/or EN 1191.
Subject to the completion of the appropriate test or tests, the extended application may cover all or some of the following examples:
—   integrity (E), integrity and radiation (EW) or integrity and insulation (EI1 or EI2) classification;
—   ambient temperature smoke control (Sa) and medium temperature smoke control (S200) classifications;
—   ability to close and durability of self-closing (C0 – C5);
—   glazed elements;
—   side, transom or over panels;
—   items of building hardware;
—   decorative and protective finishes;
—   intumescent seals and non-intumescent (e.g. smoke, draught or acoustic) seals;
—   alternative supporting construction(s).
This document does not apply to horizontal doorsets and windows.

  • Standard
    120 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides complementary product category rules (c-PCR) for Type III environmental declarations for windows and pedestrian doorsets as defined in EN 14351-1 and EN 14351-2. Windows and pedestrian doorsets additionally providing fire resistance and/or smoke control characteristics according to EN 16034 are also covered by this document.
NOTE 1   Windows that incorporate shutters and/or shutter boxes and/or blinds are in scope of this
c-PCR. For any connected electrical devices (e.g. motors, sensors) - see 6.3.5.2.
NOTE 2   For wood and wood-based products for use in construction, see EN 16485.
NOTE 3   For building hardware, see EN 17610.
This document complements the core rules for the product category of construction products as defined in EN 15804:2012+A2:2019. This document is to be used in conjunction with EN 15804:2012+A2:2019, not replace it.
NOTE 4   The assessment of social and economic performances at product level is not covered by this document.
The core PCR:
-   defines the parameters to be declared and the way in which they are collated and reported;
-   describes which stages of a product’s life cycle are considered in the EPD and which processes are to be included in the life cycle stages;
-   defines rules for the development of scenarios;
-   includes the rules for calculating the Life Cycle Inventory and the Life Cycle Impact Assessment underlying the EPD, including the specification of the data quality to be applied;
-   includes the rules for reporting the predetermined, environmental and health information that is not covered by Life Cycle Assessment (LCA) for the product, construction process(es) and construction service(s), as relevant;
-   defines the conditions under which construction products can be compared based on the information provided by EPD.
For the EPD of construction services the same rules and requirements apply as for the EPD of construction products.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to hinged and pivoted doors, doorsets and door assemblies with glass based leaves. Throughout this document the term “doorset” will be used to cover doors, doorsets and door assemblies. It prescribes the methodology for extending the application of test results obtained from fire resistance test(s) conducted in accordance with EN 1634-1 and/or EN 1634-3 and/or EN 1191.
Subject to the completion of the appropriate test or tests, the extended application may cover all or some of the following examples:
—   integrity (E), integrity and radiation (EW) or integrity and insulation (EI1 or EI2) classification;
—   ambient temperature smoke control (Sa) and medium temperature smoke control (S200) classifications;
—   ability to close and durability of self-closing (C0 – C5);
—   glazed elements;
—   side, transom or over panels;
—   items of building hardware;
—   decorative and protective finishes;
—   intumescent seals and non-intumescent (e.g. smoke, draught or acoustic) seals;
—   alternative supporting construction(s).
This document does not apply to horizontal doorsets and windows.

  • Standard
    120 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document applies to unplasticized poly(vinyl chloride) (PVC-U) profiles that are intended to be used for the fabrication of windows and doors in accordance with the EN 14351 series or EN 16034, shutters according to EN 13659 and other construction profiles in accordance with the EN 13245 series. Furthermore, this document is also applicable for profiles used in other PVC-U products, which can include recyclates. This document gives references and specifies general and product-specific design for recycling principles.
NOTE 1   In this document, the term “PVC-U profiles” is used to refer to construction profiles made from PVC-U, PVC-UE, and PVC-U-based natural fibre composites (NFC).
NOTE 2   For editorial reasons in this document the term window is used for window/door.
Criteria for the use of materials, process conditions, and recyclability are defined, which are considered during the design process.
This document defines principles to
-   obtain the highest possible share of recyclability of the PVC-U part in the profile, and
-   increase the share of PVC-U recyclate in the profile,
while complying with requirements for the final product, where existent and defined elsewhere. This document establishes flowcharts which help to assess, (i) how recyclability is evaluated and (ii) whether inclusion of rPVC-U is possible.
The following components of the final PVC-U construction product are considered in this document:
-   profiles;
-   reinforcements;
-   gaskets;
-   insulations;
-   coverings.
This document specifies only the technical connection of the profile to other components (such as glazing or hardware) and their impact on the recyclability of the PVC-U profiles. The recyclability of the other components (e.g. glazing, aluminium cover, hardware) is excluded from this document.
NOTE 3   Examples for profiles included in this document and their intended use can be found in Figure 1.
Figure 1 - Examples for profiles included in this document and their intended use (frame and sash profile with reinforcements, window, door, cladding and shutter box with shutter)

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document applies to unplasticized poly(vinyl chloride) (PVC-U) profiles that are intended to be used for the fabrication of windows and doors in accordance with the EN 14351 series or EN 16034, shutters according to EN 13659 and other construction profiles in accordance with the EN 13245 series. Furthermore, this document is also applicable for profiles used in other PVC-U products, which can include recyclates. This document gives references and specifies general and product-specific design for recycling principles.
NOTE 1   In this document, the term “PVC-U profiles” is used to refer to construction profiles made from PVC-U, PVC-UE, and PVC-U-based natural fibre composites (NFC).
NOTE 2   For editorial reasons in this document the term window is used for window/door.
Criteria for the use of materials, process conditions, and recyclability are defined, which are considered during the design process.
This document defines principles to
-   obtain the highest possible share of recyclability of the PVC-U part in the profile, and
-   increase the share of PVC-U recyclate in the profile,
while complying with requirements for the final product, where existent and defined elsewhere. This document establishes flowcharts which help to assess, (i) how recyclability is evaluated and (ii) whether inclusion of rPVC-U is possible.
The following components of the final PVC-U construction product are considered in this document:
-   profiles;
-   reinforcements;
-   gaskets;
-   insulations;
-   coverings.
This document specifies only the technical connection of the profile to other components (such as glazing or hardware) and their impact on the recyclability of the PVC-U profiles. The recyclability of the other components (e.g. glazing, aluminium cover, hardware) is excluded from this document.
NOTE 3   Examples for profiles included in this document and their intended use can be found in Figure 1.
Figure 1 - Examples for profiles included in this document and their intended use (frame and sash profile with reinforcements, window, door, cladding and shutter box with shutter)

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document, used in conjunction with ISO 834-1, specifies a method for determining the fire resistance of door and shutter assemblies designed primarily for installation within openings incorporated in vertical separating elements, such as: — hinged and pivoted doors, — horizontally sliding and vertically sliding doors, including articulated sliding doors and sectional doors, — steel single-skin folding shutters (un-insulated), — other sliding, folding doors, — tilting doors, — rolling shutter doors, — removable panels in walls, — self-closing openable windows. Requirements are included for mechanical pre-conditioning, e.g. “cycling” of door and shutter assemblies prior to the conduct of the fire-resistance test. This document does not cover: — Lift landing doors which are tested in accordance with ISO 3008-2.

  • Standard
    52 pages
    English language
    sale 15% off

This document specifies a tensile bending method and a compression bending method for determining the failure stress of welded corners and welded T-joints made from unplasticized poly(vinyl chloride) (PVC-U) profiles.
It is applicable to PVC based profiles used for the fabrication of windows and doors.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document covers hinged/pivoted and sliding doorsets with engaging fasteners (e.g. latches, deadbolts) for pedestrian use. It defines the test methods to determine the forces to open/close doors and to engage/release and lock/unlock the building hardware using a key or handle. It is only applicable to the manual operation of doorsets.
These doorsets can include:
—   emergency or panic exit devices;
—   door closing devices.
NOTE   The use of some windows involves engaging fasteners (e.g. latches, deadbolts) and can be tested in accordance with this document. Throughout the text where “door leaf”/”door leaves” is written this can also be read as “casements”/”sashes”.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document covers hinged/pivoted and sliding doorsets with engaging fasteners (e.g. latches, deadbolts) for pedestrian use. It defines the test methods to determine the forces to open/close doors and to engage/release and lock/unlock the building hardware using a key or handle. It is only applicable to the manual operation of doorsets.
These doorsets can include:
—   emergency or panic exit devices;
—   door closing devices.
NOTE   The use of some windows involves engaging fasteners (e.g. latches, deadbolts) and can be tested in accordance with this document. Throughout the text where “door leaf”/”door leaves” is written this can also be read as “casements”/”sashes”.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document applies to the whole range of shutters, awnings and blinds defined in EN 12216, described as solar protection devices in this document.
It specifies the corresponding properties and classifications:
-   relating to thermal comfort:
-   the solar factor (total solar energy transmittance);
-   the secondary heat transfer factor;
-   the direct solar transmittance;
-   relating to visual comfort:
-   the darkening performance;
-   the night privacy;
-   the visual contact with the outside;
-   the glare control;
-   the daylight utilization;
-   the rendering of colours.
NOTE   For other purposes, more detailed methods using different parameters can be used.
Some of the characteristics (e.g. gtot) are not applicable when solar protection devices are not parallel to the glazing (e.g. folding-arm awnings).
This document is not applicable to the solar protection devices using fluorescent materials.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document applies to the whole range of shutters, awnings and blinds defined in EN 12216, described as solar protection devices in this document.
It specifies the corresponding properties and classifications:
-   relating to thermal comfort:
-   the solar factor (total solar energy transmittance);
-   the secondary heat transfer factor;
-   the direct solar transmittance;
-   relating to visual comfort:
-   the darkening performance;
-   the night privacy;
-   the visual contact with the outside;
-   the glare control;
-   the daylight utilization;
-   the rendering of colours.
NOTE   For other purposes, more detailed methods using different parameters can be used.
Some of the characteristics (e.g. gtot) are not applicable when solar protection devices are not parallel to the glazing (e.g. folding-arm awnings).
This document is not applicable to the solar protection devices using fluorescent materials.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements and test methods for sensitive protective equipment put separately on the market as safety components to be used with entrance equipment such as power operated industrial, commercial and garage doors, gates and barriers, power operated pedestrian doors and power operated pedestrian entrance control equipment.
NOTE   Requirements for the safe function of the combination of protective device and industrial, commercial and garage doors and barriers are given in EN 12453.
This document deals with all significant hazards, hazardous situations and events relevant to the power operation of doors, and gates and barriers when they are used as intended and under conditions of misuse which are reasonably foreseeable as identified in Clause 4.
All lifetime phases of the sensitive protective equipment including transportation, assembly, dismantling, disabling and scrapping are considered by this document.
Whenever the term „door” is used in this document, it is deemed to cover the full scope of types and variances of doors, gates and barriers and entrance control equipment listed in the scope of EN 12453:2017+A1:2021, EN 16005:2012 and EN 17352:2022.
This document is not intended to be used for sensitive protective equipment using ultrasonic, radar, capacitive, inductive, and passive infrared and vision based technologies. For these types of equipment this document can be used as a guide to demonstrate that such a device is allowed.
This document is not applicable to sensitive protective equipment manufactured before the date of its publication.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements and test methods for sensitive protective equipment put separately on the market as safety components to be used with entrance equipment such as power operated industrial, commercial and garage doors, gates and barriers, power operated pedestrian doors and power operated pedestrian entrance control equipment.
NOTE   Requirements for the safe function of the combination of protective device and industrial, commercial and garage doors and barriers are given in EN 12453.
This document deals with all significant hazards, hazardous situations and events relevant to the power operation of doors, and gates and barriers when they are used as intended and under conditions of misuse which are reasonably foreseeable as identified in Clause 4.
All lifetime phases of the sensitive protective equipment including transportation, assembly, dismantling, disabling and scrapping are considered by this document.
Whenever the term „door” is used in this document, it is deemed to cover the full scope of types and variances of doors, gates and barriers and entrance control equipment listed in the scope of EN 12453:2017+A1:2021, EN 16005:2012 and EN 17352:2022.
This document is not intended to be used for sensitive protective equipment using ultrasonic, radar, capacitive, inductive, and passive infrared and vision based technologies. For these types of equipment this document can be used as a guide to demonstrate that such a device is allowed.
This document is not applicable to sensitive protective equipment manufactured before the date of its publication.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the classifications, requirements and test methods for unplasticized poly(vinyl chloride) (PVC-U) profiles with thermo-laminated foils designed for external uses which are intended to be used for the fabrication of windows and doors.
NOTE 1   For editorial reasons, in this document, the term "window" is used for window/door.
NOTE 2   For the purpose of production control, test methods other than those specified in this document can be used.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the classifications, requirements and test methods for unplasticized poly(vinyl chloride) (PVC-U) profiles with thermo-laminated foils designed for external uses which are intended to be used for the fabrication of windows and doors.
NOTE 1   For editorial reasons, in this document, the term "window" is used for window/door.
NOTE 2   For the purpose of production control, test methods other than those specified in this document can be used.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document covers single and double leaf, hinged and pivoted, steel based doorsets except steel doorsets with metal framed door leaves covered by EN 15269-5. It prescribes the methodology for extending the application of test results obtained from fire resistance test(s) conducted in accordance with EN 1634-1.
Subject to the completion of the appropriate test or tests, the extended application may cover all or some of the following examples:
-   integrity (E), integrity and radiation (EW) or integrity and insulation (EI1 or EI2) classification;
-   door leaf;
-   side panels, transom panels, flush overpanels;
-   air transfer grilles (e.g. ventilation grilles/louvres);
-   components (e.g. frame/suspension system) fixed to the supporting construction (e.g. wall/ceiling);
-   glazing within the doorset (e.g. for door leaf, side, transom and flush overpanels);
-   items of building hardware;
-   decorative and protective finishes;
-   intumescent seals, strips and non-intumescent (smoke, draught or acoustic) seals;
-   alternative supporting construction(s).
This document does not cover horizontally installed doorsets (e.g. traps).
The effect on the classification ‘C’ for the doorsets following an extended application process is not addressed in this document.

  • Standard
    141 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document covers single and double leaf, hinged and pivoted, steel based doorsets except steel doorsets with metal framed door leaves covered by EN 15269-5. It prescribes the methodology for extending the application of test results obtained from fire resistance test(s) conducted in accordance with EN 1634-1.
Subject to the completion of the appropriate test or tests, the extended application may cover all or some of the following examples:
-   integrity (E), integrity and radiation (EW) or integrity and insulation (EI1 or EI2) classification;
-   door leaf;
-   side panels, transom panels, flush overpanels;
-   air transfer grilles (e.g. ventilation grilles/louvres);
-   components (e.g. frame/suspension system) fixed to the supporting construction (e.g. wall/ceiling);
-   glazing within the doorset (e.g. for door leaf, side, transom and flush overpanels);
-   items of building hardware;
-   decorative and protective finishes;
-   intumescent seals, strips and non-intumescent (smoke, draught or acoustic) seals;
-   alternative supporting construction(s).
This document does not cover horizontally installed doorsets (e.g. traps).
The effect on the classification ‘C’ for the doorsets following an extended application process is not addressed in this document.

  • Standard
    141 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method to determine the windborne debris-resistance of windows (including skylights), doors or curtain walling to natural threats characterized by simulated destructive-windstorm events. The test method can also be used on windstorm protective systems for the missile impact tests. The test method determines the performance of windows, doors or curtain walling, under conditions representative of events that occur in severe, destructive-windstorm environments using simulated missile impact(s) followed by the application of cyclic test load. This document is applicable to the design of an entire window (including skylight), door or curtain walling, and also in case these systems are tested in combination with windstorm protective system assemblies and their installation. This document is not applicable to: — exterior garage doors and rolling doors are beyond the scope of this document and this document does not refer to: — bullet; — blast; — flood resistance. — windstorm protective systems when tested alone, i.e. not tested in combination with windows, skylights, doors or curtain walling. When windows, skylights, doors or curtain walling are tested in combination with windstorm protective systems, pass and fail assessment criteria (see Clause 9), only refer to windows, skylights, doors or curtain walling themselves. This document does not define pass or fail criteria for windstorm protective systems.

  • Standard
    64 pages
    English language
    sale 15% off

This document specifies requirements regarding design and test methods for power operated pedestrian doorsets. Examples of how the doorset constructions may be operated include: electro-mechanically, electro-hydraulically, electro-magnetically or pneumatically.
This document covers safety in use of power operated pedestrian doorsets used for normal access as well as in emergency and escape routes and as fire resistance and/or smoke control doorsets.
The type of doorsets covered include power operated pedestrian sliding, swing and revolving doorsets, including balanced doorsets and folding doorsets with a horizontally moving door leaf.
This document deals with all significant hazards, hazardous situations and events relevant to power operated doorsets when they are used as intended and under conditions of misuse which are reasonably foreseeable by the manufacturer.
All lifetime phases of the power operated pedestrian doorsets including transportation, assembly, dismantling, disabling and scrapping are considered by this document.
This document does not apply to:
-   vertically moving doors;
-   doors on lifts;
-   doors on vehicles;
-   power operated doors or gates mainly intended for vehicular traffic or access for goods;
-   doors used in industrial processes;
-   partition walls;
-   doors outside the reach of people (such as crane gantry fences);
-   turnstiles;
-   platform doors;
-   traffic barriers.
This document does not cover special functions of doorsets, such as security in banks, airports, etc. or fire and/or smoke compartmentation, where conformity of the specific function with requirements of the application is the preference.
This document does not deal with any specific requirements on noise emitted from power operated pedestrian doorsets as their noise emission is not considered to be a relevant hazard.
NOTE   Noise emission of power operated pedestrian doorsets is not a significant hazard for the users of these products. It is a comfort aspect.
This document is not applicable to power operated pedestrian doorsets manufactured before the date of its publication.
This document does not cover operation in environments where there is a risk of explosion.

  • Standard
    67 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements regarding design and test methods for power operated pedestrian doorsets. Examples of how the doorset constructions may be operated include: electro-mechanically, electro-hydraulically, electro-magnetically or pneumatically.
This document covers safety in use of power operated pedestrian doorsets used for normal access as well as in emergency and escape routes and as fire resistance and/or smoke control doorsets.
The type of doorsets covered include power operated pedestrian sliding, swing and revolving doorsets, including balanced doorsets and folding doorsets with a horizontally moving door leaf.
This document deals with all significant hazards, hazardous situations and events relevant to power operated doorsets when they are used as intended and under conditions of misuse which are reasonably foreseeable by the manufacturer.
All lifetime phases of the power operated pedestrian doorsets including transportation, assembly, dismantling, disabling and scrapping are considered by this document.
This document does not apply to:
-   vertically moving doors;
-   doors on lifts;
-   doors on vehicles;
-   power operated doors or gates mainly intended for vehicular traffic or access for goods;
-   doors used in industrial processes;
-   partition walls;
-   doors outside the reach of people (such as crane gantry fences);
-   turnstiles;
-   platform doors;
-   traffic barriers.
This document does not cover special functions of doorsets, such as security in banks, airports, etc. or fire and/or smoke compartmentation, where conformity of the specific function with requirements of the application is the preference.
This document does not deal with any specific requirements on noise emitted from power operated pedestrian doorsets as their noise emission is not considered to be a relevant hazard.
NOTE   Noise emission of power operated pedestrian doorsets is not a significant hazard for the users of these products. It is a comfort aspect.
This document is not applicable to power operated pedestrian doorsets manufactured before the date of its publication.
This document does not cover operation in environments where there is a risk of explosion.

  • Standard
    67 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60335-2-103:2023 deals with the safety of electric drives for horizontally and vertically moving gates, doors, garage doors and windows for household and similar purposes, their rated voltage being not more than 250 V for single-phase drives and 600 V for other drives including direct current (DC) supplied appliances and battery-operated appliances. It also covers the hazards associated with the movement of the driven part.
Drives not intended for normal household use but which nevertheless can be a source of danger to the public, such as drives intended to be used by laymen in shops, offices, hotels, restaurants, hospitals, in industry and on farms, are within the scope of this standard.
Requirements for drives for doors that can be used in emergency routes and exits are given in normative Annex AA.
Examples of drives within the scope of this standard are drives for
– folding doors;
– revolving doors;
– rolling doors;
– roof windows;
– sectional overhead doors;
– swinging and sliding gates or doors.
Drives can be supplied with a driven part.
As far as is practicable, this standard deals with the common hazards presented by drives that are encountered by all persons in and around the home. However, in general, it does not take into account
– persons (including children) whose physical, sensory or mental capabilities; or lack of experience and knowledge prevents them from using the drive safely without supervision or instruction;
– children playing with the drive.
For appliances intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary. In many countries, additional requirements are specified by the national health authorities, the national authorities responsible for the protection of labour, the national water supply authorities and similar authorities.
This standard does not apply to drives
– for vertically moving garage doors for residential use (60335-2-95);
– for shutters covering doors and windows (including locations where the door is set back from the shutter), awnings, blinds and similar equipment (60335-2-97);
– intended exclusively to be used by trained persons in commercial and industrial premises;
– for specific purposes, such as fire doors;
– for natural smoke exhaust ventilators not used as windows (ISO 21927-2);
– intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas).
This standard does not apply to movement of a pedestrian door where such movement is based solely on stored energy.
This fourth edition cancels and replaces the third edition published in 2015, Amendment 1:2017 and Amendment 2:2019. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) the text has been aligned with IEC 60335-1:2020;
b) scope includes DC-supplied appliances and battery-operated appliances (Clause 1);
c) some notes have been converted to normative text (Clause 1);
d) additional requirements for installation instructions have been incorporated (7.12);
e) application of test probe 18 and test probe 19 have been introduced (8.1.1, 20.2, Annexes BB, CC and DD);
f) addition of surface temperatures for external accessible surfaces (11.3, 11.8);
g) requirements for loading accessible appliance outlets and socket outlets have been added (11.7);
h) requirements for appliances incorporating integral batteries or separable batteries have been added (11.7);
i) requirements have been added for drives intended for permanent connection delivered with a connector to ease the installation (22.108, 24.101, 25.3).
This part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments unless that edition precludes it; in that case, the latest edition that does not preclude it is used. It was established on the basis of the sixth edition (2020) of tha

  • Standard
    149 pages
    English language
    sale 15% off
  • Standard
    411 pages
    English language
    sale 15% off
  • Standard
    149 pages
    English and French language
    sale 15% off

IEC 60335-2-97:2023 deals with the safety of electric drives for shutters, blinds and awnings, intended for household and similar purposes, their rated voltage being not more than 250 V for single-phase drives and 480 V for other drives, including direct current (DC) supplied appliances and battery-operated appliances.
Examples of equipment that can be driven are
– spring controlled folding arm awnings;
– curtains;
– grilles covering doors and windows;
– projection screens;
– shutters covering doors and windows;
– draperies.
Drives can be supplied with a driven part.
Drives not intended for normal household use but that nevertheless can be a source of danger to the public, such as drives intended to be used by laymen in shops, in light industry, on farms and on industrial premises, are within the scope of this standard.
As far as is practicable, this standard deals with the common hazards presented by drives that are encountered by all persons in and around the home. However, in general, it does not take into account
– persons (including children) whose physical, sensory or mental capabilities; or lack of experience and knowledge prevents them from using the drive safely without supervision or instruction;
– children playing with the drive.
For appliances intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary. In many countries, additional requirements are specified by the national health authorities, the national authorities responsible for the protection of labour, the national water supply authorities and similar authorities.
This standard does not apply to
– drives intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas);
– drives for vertically moving garage doors for residential use (IEC 60335-2-95);
– drives for gates, doors and windows (IEC 60335-2-103);
– drives used in premises such as hangars or in heavy industry;
– drives for theatre curtains.
This fourth edition cancels and replaces the third edition published in 2016 and Amendment 1: 2019. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) the text has been aligned with IEC 60335-1:2020;
b) scope includes DC-supplied appliances and battery-operated appliances (Clause 1);
c) some notes have been converted to normative text (Clause 1, 5.10, 20.101, 20.103);
d) use of artificial loads is introduced (5.10);
e) application of test probe 19 has been introduced (8.1.1, 20.2);
f) addition of surface temperatures for external accessible surfaces (11.3, 11.8);
g) requirements are added for drives intended for permanent connection delivered with a connector to ease the installation (22.102, 24.1.101, 25.3);
h) clarification for connectors that are non-detachable once engaged (24.1.5).
i) added requirements for instructions for parts of class III construction supplied from a detachable power supply part (7.12, 7.12.1).
This part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments unless that edition precludes it; in that case, the latest edition that does not preclude it is used. It was established on the basis of the sixth edition (2020) of that standard.

  • Standard
    93 pages
    English language
    sale 15% off
  • Standard
    281 pages
    English language
    sale 15% off
  • Standard
    61 pages
    English and French language
    sale 15% off

This document specifies the test method, safety requirements and classification when determining the effect on a complete window or pedestrian doorset impacted with a soft and heavy body. Any secondary moving sashes, casements, leaves, mullions, transoms, T-connectors or fixed lights which can be mounted internally to the main casements or sashes, are intended to also be similarly tested and evaluated for the classification for the complete product.
The test applies to all types of infill of whatever materials including glass. It is not intended to classify the strength of the glass when used as an infill. It is intended to assess the interactions between all components of a window with particular regard to safety in use. It is also applicable to assess the ability of a doorset to keep in place glazed parts.
NOTE 1   The test method is aimed for glazed pedestrian doorsets with injury risk, but can also be used for other types of pedestrian doorsets if requested by the client.
NOTE 2   The test has been devised to suit all window or pedestrian doorset types, configurations and materials.
NOTE 3   For the classification of glass see EN 12600.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the classifications, requirements and test methods for unplasticized poly(vinyl chloride) (PVC-U) profiles covered with foils designed for external uses bonded with adhesives which are intended to be used for the fabrication of windows and doors.
NOTE 1   For editorial reasons, in this document, the term "window" is used for window/door.
NOTE 2   For the purpose of production control, test methods other than those specified in this document can be used.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the test method, safety requirements and classification when determining the effect on a complete window or pedestrian doorset impacted with a soft and heavy body. Any secondary moving sashes, casements, leaves, mullions, transoms, T-connectors or fixed lights which can be mounted internally to the main casements or sashes, are intended to also be similarly tested and evaluated for the classification for the complete product.
The test applies to all types of infill of whatever materials including glass. It is not intended to classify the strength of the glass when used as an infill. It is intended to assess the interactions between all components of a window with particular regard to safety in use. It is also applicable to assess the ability of a doorset to keep in place glazed parts.
NOTE 1   The test method is aimed for glazed pedestrian doorsets with injury risk, but can also be used for other types of pedestrian doorsets if requested by the client.
NOTE 2   The test has been devised to suit all window or pedestrian doorset types, configurations and materials.
NOTE 3   For the classification of glass see EN 12600.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the classifications, requirements and test methods for unplasticized poly(vinyl chloride) (PVC-U) profiles covered with foils designed for external uses bonded with adhesives which are intended to be used for the fabrication of windows and doors.
NOTE 1   For editorial reasons, in this document, the term "window" is used for window/door.
NOTE 2   For the purpose of production control, test methods other than those specified in this document can be used.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for assessment of the mechanical strength of metal profiles incorporating a thermal barrier having mechanical performance depending on their intended use.
It also specifies the tests to determine the characteristic values of mechanical properties of the thermal barrier profile and to assess the effect of different conditionings of the thermal barrier on the mechanical performance of the connection.
This document does not apply to thermal barriers which do not give a contribution to the mechanical resistance of the profiles.
This document is applicable to thermal barrier profiles designed mainly for windows, doors, screens and curtain walls.
This document does not apply to thermal barriers made only of metal profiles connected with metal pins or screws.
This current edition of EN 14024 will supersede EN 14024:2004. Differences in test procedures between the two versions will not lead to significant differences in test results. Therefore, existing test results according to EN 14024:2004 are considered as equivalent to new test results according to the current edition of EN 14024.

  • Standard
    63 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for assessment of the mechanical strength of metal profiles incorporating a thermal barrier having mechanical performance depending on their intended use.
It also specifies the tests to determine the characteristic values of mechanical properties of the thermal barrier profile and to assess the effect of different conditionings of the thermal barrier on the mechanical performance of the connection.
This document does not apply to thermal barriers which do not give a contribution to the mechanical resistance of the profiles.
This document is applicable to thermal barrier profiles designed mainly for windows, doors, screens and curtain walls.
This document does not apply to thermal barriers made only of metal profiles connected with metal pins or screws.
This current edition of EN 14024 will supersede EN 14024:2004. Differences in test procedures between the two versions will not lead to significant differences in test results. Therefore, existing test results according to EN 14024:2004 are considered as equivalent to new test results according to the current edition of EN 14024.

  • Standard
    63 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60335-2-103:2015(E) deals with the safety of electric drives for horizontally and vertically moving gates, doors, garage doors and windows for household and similar purposes, their rated voltage being not more than 250 V for single-phase drives and 480 V for other drives. It also covers the hazards associated with the movement of the driven part. Battery-operated drives and other d.c. supplied drives are within the scope of this standard. Dual supply drives, either mains-supplied or battery-operated, are regarded as battery-operated drives when operated in the battery mode. Drives not intended for normal household use but which nevertheless may be a source of danger to the public, such as drives intended to be used by laymen in shops, offices, hotels, restaurants, hospitals, in industry and on farms, are within the scope of this standard.
Requirements for drives for doors that may be used in emergency routes and exits are given in Annex AA. Examples of drives within the scope of this standard are drives for:
- folding doors;
- revolving doors;
- rolling doors;
- roof windows;
- sectional overhead doors;
- swinging and sliding gates or doors. As far as is practicable, this standard deals with the common hazards presented by drives that are encountered by all persons in and around the home. However, in general, it does not take into account persons (including children) whose physical, sensory or mental capabilities; or lack of experience and knowledge prevents them from using the drive safely without supervision or instruction or children playing with the drive. It was established on the basis of the fifth edition (2010) of that standard. This third edition cancels and replaces the second edition published in 2006 and its Amendment 1 (2010). It constitutes a technical revision. The principal changes in this edition as compared with the second edition of IEC 60335-2-103 are as follows (minor changes are not listed): modification of requirements in Clause 20 by introduction of new annexes. The attention of National Committees is drawn to the fact that equipment manufacturers and testing organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this standard be adopted for implementation nationally not earlier than 12 months or later than 36 months from the date of its publication.
Key words: Drives, Gates, Doors, Windows.

  • Standard
    69 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60335-2-97:2016 deals with the safety of electric drives for shutters, blinds and awnings, intended for household and similar purposes, their rated voltage being not more than 250 V for single-phase drives and 480 V for other drives. Battery-operated drives and other d.c. supplied drives are within the scope of this standard. Examples of equipment that can be driven are:
- spring controlled folding arm awnings;
- curtains;
- grilles covering doors and windows;
- projection screens;
- shutters covering doors and windows and draperies. Drives may be supplied with a driven part. Drives not intended for normal household use but that nevertheless may be a source of danger to the public, such as drives intended to be used by laymen in shops, in light industry, on farms and on industrial premises, are within the scope of this standard. Attention is drawn to the fact that for drives intended to be used in vehicles or on board ships or aircraft, additional requirements may be necessary. This standard does not apply to
- drives intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas);
- drives for vertically moving garage doors for residential use (IEC 60335-2-95);
- drives for rolling doors (IEC 60335-2-103);
- drives used in premises such as hangars or in heavy industry and drives for theatre curtains. As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home. However, in general, it does not take into account:
- persons (including children) whose physical, sensory or mental capabilities or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction or
- children playing with the appliance. This third edition cancels and replaces the second edition published in 2002 including its Amendment 1 (2004) and its Amendment 2 (2008). It constitutes a technical revision. The principal changes in this edition as compared with the second edition of IEC 60335-2-97 are as follows (minor changes are not listed):
- Deleted "rolling" from the title and modified the scope to cover appliance types other than shutters, awnings, and blinds that are operated in a rolling way;
- Revised 19.13 to allow drives to obtain a safe position;
- Added 19.101 to provide a new abnormal test for drives with rated operating time;
- Added 20.104.4 to establish a test intended to cover horizontal movement (non-rolling) drive parts;
- Added 20.104.5 to provide an additional test to cover rolling grills to address the risk of being lifted;
- Modified 22.46 and Annex R to introduce software requirements for programmable electronic circuits used to comply with Clause 20;
- Added 22.101 to introduce a requirement to prevent inadvertent adjustments that would lead to unsafe application of drives;
- Added examples of swing shutters and sliding shutters in Figure 101. The attention of National Committees is drawn to the fact that equipment manufacturers and testing organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this standard be adopted for implementation nationally not earlier than 12 months or later than 36 months from the date

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric drives for garage doors for residential use that open and close in a vertical direction, the rated voltage of the drives being not more than 250 V for single-phase appliances and 480 V for other appliances.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric drives for shutters, blinds and awnings, intended for household and similar purposes, their rated voltage being not more than 250 V for single-phase drives and 480 V for other drives

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric drives for horizontally and vertically moving gates, doors, garage doors and windows for household and similar purposes, their rated voltage being not more than 250 V for single-phase drives and 480 V for other drives. It also covers the hazards associated with the movement of the driven part.

  • Amendment
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric drives for horizontally and vertically moving gates, doors, garage doors and windows for household and similar purposes, their rated voltage being not more than 250 V for single-phase drives and 480 V for other drives. It also covers the hazards associated with the movement of the driven part.

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric drives for garage doors for residential use that open and close in a vertical direction, the rated voltage of the drives being not more than 250 V for single-phase appliances and 480 V for other appliances.

  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric drives for shutters, blinds and awnings, intended for household and similar purposes, their rated voltage being not more than 250 V for single-phase drives and 480 V for other drives

  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric drives for horizontally and vertically moving gates, doors, garage doors and windows for household and similar purposes, their rated voltage being not more than 250 V for single-phase drives and 480 V for other drives. It also covers the hazards associated with the movement of the driven part.

  • Amendment
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day