This document applies to portable residual current devices (PRCDs) for household and similar uses, consisting of a plug, a residual current device (RCD) and one or more socket-outlets or a provision for connection. They do not incorporate overcurrent protection. They are intended for single- and two-phase systems for rated currents not exceeding 16 A for rated voltages not exceeding 250 V AC, or for rated current not exceeding 32 A for rated voltages not exceeding 130 V AC to earth. They are intended to provide protection against shock hazard in case of direct contact, in addition to the protection provided by the fixed installations for the circuit downstream. PRCDs have a rated residual operating current not exceeding 0,03 A. The plug and socket-outlet parts of a PRCD are covered by the national standard of the country where the PRCD is placed on the market. If no national requirements exist, IEC 60884 1 is used. This document applies to portable devices performing simultaneously the functions of detection of the residual current, of comparison of the value of this current with the residual operating value and of opening of the protected circuit when the residual current exceeds this value. PRCDs providing an additional function of detecting faults on the supply side with a defined behaviour in case of supply failures or miswiring (PRCD-S) are also covered by this document. PRCDs are not intended to be used as parts of fixed installations. Their connecting means can be plugs, socket-outlets, terminals or cords. NOTE 1 The requirements for PRCDs are in compliance with the general requirements of IEC 60755. PRCDs are essentially intended to be operated by ordinary persons and designed not to require maintenance. NOTE 2 An integral fuse is used, if necessary, for the relevant plug and socket-outlet system. The switching contacts of the PRCDs are not intended to provide isolation, as isolation can be ensured by disconnecting the plug. The requirements of this document apply for environmental conditions as defined in 7.1. Additional requirements can be necessary for PRCDs used in locations having more severe environmental conditions. PRCDs including batteries are not covered by this document. This document does not contain additional requirements for PRCDs without earthing contacts for which specific requirements can apply. This document can, however, be used as a guide for such devices which are intended to be used with Class II appliances only.

  • Draft
    145 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document applies to portable residual current devices (PRCDs) for household and similar uses, consisting of a plug, a residual current device (RCD) and one or more socket-outlets or a provision for connection. They do not incorporate overcurrent protection. They are intended for single- and two-phase systems for rated currents not exceeding 16 A for rated voltages not exceeding 250 V AC. They are intended to provide protection against shock hazard in case of direct contact, in addition to the protection provided by the fixed installations for the circuit downstream. PRCDs have a rated residual operating current not exceeding 0,03 A. The plug and socket-outlet parts of a PRCD are covered by the national standard of the country where the PRCD is placed on the market. This document applies to portable devices performing simultaneously the functions of detection of the residual current, of comparison of the value of this current with the residual operating value and of opening of the protected circuit when the residual current exceeds this value. PRCDs providing an additional function of detecting faults on the supply side with a defined behaviour in case of supply failures or miswiring (PRCD-S) are also covered by this document. PRCDs are not intended to be used as parts of fixed installations. Their connecting means can be plugs, socket-outlets, terminals or cords. NOTE 1 The requirements for PRCDs are in compliance with the general requirements of IEC 60755. PRCDs are essentially intended to be operated by ordinary persons and designed not to require maintenance. NOTE 2 An integral fuse is used, if necessary, for the relevant plug and socket-outlet system. The switching contacts of the PRCDs are not intended to provide isolation, as isolation can be ensured by disconnecting the plug. The requirements of this document apply for environmental conditions as defined in 7.1. Additional requirements can be necessary for PRCDs used in locations having more severe environmental conditions. PRCDs including batteries are not covered by this document. This document does not contain additional requirements for PRCDs without earthing contacts for which specific requirements can apply. This document can, however, be used as a guide for such devices which are intended to be used with Class II appliances only.

  • Draft
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60730-2-14: 2025 applies to automatic electric actuators
• for use in, on, or in association with equipment for household appliance and similar use;
NOTE 1 Throughout this document, the word "equipment" means "appliance and equipment" and "control" means "electric actuator".
EXAMPLE 1 Electric actuators for appliances within the scope of IEC 60335.
• for building automation within the scope of ISO 16484 series and IEC 63044 series (HBES/BACS);
EXAMPLE 2 Independently mounted electric actuators for use in smart grid systems and for building automation systems within the scope of ISO 16484-2.
for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications;
EXAMPLE 3 Electric actuators for commercial catering, heating, and air-conditioning equipment.
• that are smart enabled;
• that are AC or DC powered electric actuators with a rated voltage not exceeding 690 V AC or 600 V DC;
• used in, on, or in association with equipment that use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof;
• utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs;
• using NTC or PTC thermistors and to discrete thermistors, requirements for which are contained in Annex J;
• that are mechanically or electrically operated, responsive to or controlling such characteristics as temperature, pressure, passage of time, humidity, light, electrostatic effects, flow, or liquid level, current, voltage, acceleration, or combinations thereof; as well as manual controls when such are electrically and/or mechanically integral with automatic controls.
NOTE 2 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058-1-1.
This document applies to
– the inherent safety of automatic electric actuators, and
– functional safety of automatic electric actuators and safety related systems,
– controls where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and performance of the controlled system,
– the operating values, operating times, and operating sequences where such are associated with equipment safety.
This document specifies the requirements for construction, operation and testing of automatic electric actuators used in, on, or in association with an equipment.
This document does not
• apply to automatic electric actuators intended exclusively for industrial process applications unless explicitly mentioned in the relevant part 2 or the equipment standard. However, this document can be applied to evaluate automatic electric actuators intended specifically for industrial applications in cases where no relevant safety standard exists;
• take into account the response value of an automatic action of an electric actuator, if such a response value is dependent upon the method of mounting the electric actuator in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer will apply;
• address the integrity of the output signal to the network devices, such as interoperability with other devices unless it has been evaluated as part of the control syst

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60730-2-14: 2025 applies to automatic electric actuators • for use in, on, or in association with equipment for household appliance and similar use; NOTE 1 Throughout this document, the word "equipment" means "appliance and equipment" and "control" means "electric actuator". EXAMPLE 1 Electric actuators for appliances within the scope of IEC 60335. • for building automation within the scope of ISO 16484 series and IEC 63044 series (HBES/BACS); EXAMPLE 2 Independently mounted electric actuators for use in smart grid systems and for building automation systems within the scope of ISO 16484-2. for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications; EXAMPLE 3 Electric actuators for commercial catering, heating, and air-conditioning equipment. • that are smart enabled; • that are AC or DC powered electric actuators with a rated voltage not exceeding 690 V AC or 600 V DC; • used in, on, or in association with equipment that use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof; • utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs; • using NTC or PTC thermistors and to discrete thermistors, requirements for which are contained in Annex J; • that are mechanically or electrically operated, responsive to or controlling such characteristics as temperature, pressure, passage of time, humidity, light, electrostatic effects, flow, or liquid level, current, voltage, acceleration, or combinations thereof; as well as manual controls when such are electrically and/or mechanically integral with automatic controls. NOTE 2 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058-1-1. This document applies to – the inherent safety of automatic electric actuators, and – functional safety of automatic electric actuators and safety related systems, – controls where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and performance of the controlled system, – the operating values, operating times, and operating sequences where such are associated with equipment safety. This document specifies the requirements for construction, operation and testing of automatic electric actuators used in, on, or in association with an equipment. This document does not • apply to automatic electric actuators intended exclusively for industrial process applications unless explicitly mentioned in the relevant part 2 or the equipment standard. However, this document can be applied to evaluate automatic electric actuators intended specifically for industrial applications in cases where no relevant safety standard exists; • take into account the response value of an automatic action of an electric actuator, if such a response value is dependent upon the method of mounting the electric actuator in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer will apply; • address the integrity of the output signal to the network devices, such as interoperability with other devices unless it has been evaluated as part of the control syst

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEXT ACTION: CCMC ACTION to request HAS assessment @ PUB when HAS system is operational
2022-01-17: Under discussion with the desk officer. upon the greenlight of the desk officer, it can be published.

  • Amendment
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60730-2-14: 2025 applies to automatic electric actuators
• for use in, on, or in association with equipment for household appliance and similar use;
NOTE 1 Throughout this document, the word "equipment" means "appliance and equipment" and "control" means "electric actuator".
EXAMPLE 1 Electric actuators for appliances within the scope of IEC 60335.
• for building automation within the scope of ISO 16484 series and IEC 63044 series (HBES/BACS);
EXAMPLE 2 Independently mounted electric actuators for use in smart grid systems and for building automation systems within the scope of ISO 16484-2.
for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications;
EXAMPLE 3 Electric actuators for commercial catering, heating, and air-conditioning equipment.
• that are smart enabled;
• that are AC or DC powered electric actuators with a rated voltage not exceeding 690 V AC or 600 V DC;
• used in, on, or in association with equipment that use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof;
• utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs;
• using NTC or PTC thermistors and to discrete thermistors, requirements for which are contained in Annex J;
• that are mechanically or electrically operated, responsive to or controlling such characteristics as temperature, pressure, passage of time, humidity, light, electrostatic effects, flow, or liquid level, current, voltage, acceleration, or combinations thereof; as well as manual controls when such are electrically and/or mechanically integral with automatic controls.
NOTE 2 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058-1-1.
This document applies to
– the inherent safety of automatic electric actuators, and
– functional safety of automatic electric actuators and safety related systems,
– controls where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and performance of the controlled system,
– the operating values, operating times, and operating sequences where such are associated with equipment safety.
This document specifies the requirements for construction, operation and testing of automatic electric actuators used in, on, or in association with an equipment.
This document does not
• apply to automatic electric actuators intended exclusively for industrial process applications unless explicitly mentioned in the relevant part 2 or the equipment standard. However, this document can be applied to evaluate automatic electric actuators intended specifically for industrial applications in cases where no relevant safety standard exists;
• take into account the response value of an automatic action of an electric actuator, if such a response value is dependent upon the method of mounting the electric actuator in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer will apply;
• address the integrity of the output signal to the network devices, such as interoperability with other devices unless it has been evaluated as part of the control system;
• apply to electric actuators which are mechanically integrated with valves covered by a separate part 2 (e.g. IEC 60730-2-8);
• apply to electric motors, requirements for which are contained in IEC 60034.
This edition includes the following significant technical changes with respect to the previous edition:
Adoption of IEC 60730-1:2022 with all its significant changes to IEC 60730-1:2013, IEC 60730‑1:2013/AMD1:2015 and IEC 60730-1:2013/AMD2:2020.

  • Standard
    52 pages
    English and French language
    sale 15% off

Common modifications for the adoption as a European Standard of IEC 61084-1:2017 ed 2.0 (PR= 69866).

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part 1 of the EN IEC 61084 series specifies general requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V AC and 1 500 V DC.

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Common modifications for the adoption as a European Standard of IEC 61084-1:2017 ed 2.0 (PR= 69866).

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part 1 of the EN IEC 61084 series specifies general requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V AC and 1 500 V DC.

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61084-1:2017 specifies requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V AC and 1 500 V DC.
This document does not apply to conduit systems, cable tray systems, cable ladder systems, power track systems or equipment covered by other standards.
This second edition cancels and replaces the first edition published in 1991 and Amendment 1:1993. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- classification;
- construction;
- mechanical and electrical properties.
This part of the IEC 61084 series is not intended to be used by itself.

  • Standard
    90 pages
    English language
    sale 15% off
  • Standard
    90 pages
    English and French language
    sale 15% off

IEC 60335-2-95:2023 deals with the safety of electric drives for garage doors for residential use that open and close in a vertical direction, the rated voltage of the drives being not more than 250 V for single-phase appliances and 480 V for other appliances, including direct current (DC) supplied appliances and battery-operated appliances. It also covers the hazards associated with the movement of these electrically driven garage doors.
The drive can be supplied with a garage door.
This standard also applies to entrapment protection devices for use with drives. It does not cover hazards related to the mechanisms of the door itself.
As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home. However, in general, it does not take into account playing with the appliance by young children, but recognizes that children can be in the vicinity of the garage door.
For appliances intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary. In many countries, additional requirements are specified by the national health authorities, the national authorities responsible for the protection of labour, the national water supply authorities and similar authorities.
This standard does not apply to drives
– for shutters, awnings, blinds and similar equipment (IEC 60335-2-97);
– for gates, doors and windows (IEC 60335-2-103);
– for commercial and industrial purposes;
– intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas).
This fifth edition cancels and replaces the fourth edition published in 2019. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) the text has been aligned with IEC 60335-1:2020;
b) scope includes DC-supplied appliances and battery-operated appliances (Clause 1);
c) some notes have been converted to normative text (Clause 1, 7.12.1, 7.101, 20.103, 20.107, 22.104);
d) application of test probe 19 has been introduced (8.1.1, 20.2);
e) addition of surface temperatures for external accessible surfaces (11.3, 11.8);
f) requirements are added for drives intended for permanent connection delivered with a connector to ease the installation (22.110, 24.1.101, 25.3);
g) clarification for connectors that are non-detachable once engaged (24.1.5).
This part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments unless that edition precludes it; in that case, the latest edition that does not preclude it is used. It was established on the basis of the sixth edition (2020) of that standard.

  • Standard
    96 pages
    English language
    sale 15% off
  • Standard
    284 pages
    English language
    sale 15% off
  • Standard
    65 pages
    English and French language
    sale 15% off

IEC 60335-2-97:2023 deals with the safety of electric drives for shutters, blinds and awnings, intended for household and similar purposes, their rated voltage being not more than 250 V for single-phase drives and 480 V for other drives, including direct current (DC) supplied appliances and battery-operated appliances.
Examples of equipment that can be driven are
– spring controlled folding arm awnings;
– curtains;
– grilles covering doors and windows;
– projection screens;
– shutters covering doors and windows;
– draperies.
Drives can be supplied with a driven part.
Drives not intended for normal household use but that nevertheless can be a source of danger to the public, such as drives intended to be used by laymen in shops, in light industry, on farms and on industrial premises, are within the scope of this standard.
As far as is practicable, this standard deals with the common hazards presented by drives that are encountered by all persons in and around the home. However, in general, it does not take into account
– persons (including children) whose physical, sensory or mental capabilities; or lack of experience and knowledge prevents them from using the drive safely without supervision or instruction;
– children playing with the drive.
For appliances intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary. In many countries, additional requirements are specified by the national health authorities, the national authorities responsible for the protection of labour, the national water supply authorities and similar authorities.
This standard does not apply to
– drives intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas);
– drives for vertically moving garage doors for residential use (IEC 60335-2-95);
– drives for gates, doors and windows (IEC 60335-2-103);
– drives used in premises such as hangars or in heavy industry;
– drives for theatre curtains.
This fourth edition cancels and replaces the third edition published in 2016 and Amendment 1: 2019. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) the text has been aligned with IEC 60335-1:2020;
b) scope includes DC-supplied appliances and battery-operated appliances (Clause 1);
c) some notes have been converted to normative text (Clause 1, 5.10, 20.101, 20.103);
d) use of artificial loads is introduced (5.10);
e) application of test probe 19 has been introduced (8.1.1, 20.2);
f) addition of surface temperatures for external accessible surfaces (11.3, 11.8);
g) requirements are added for drives intended for permanent connection delivered with a connector to ease the installation (22.102, 24.1.101, 25.3);
h) clarification for connectors that are non-detachable once engaged (24.1.5).
i) added requirements for instructions for parts of class III construction supplied from a detachable power supply part (7.12, 7.12.1).
This part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments unless that edition precludes it; in that case, the latest edition that does not preclude it is used. It was established on the basis of the sixth edition (2020) of that standard.

  • Standard
    93 pages
    English language
    sale 15% off
  • Standard
    281 pages
    English language
    sale 15% off
  • Standard
    61 pages
    English and French language
    sale 15% off

IEC 61540:2023 applies to portable residual current devices (PRCDs) for household and similar uses, consisting of a plug, a residual current device (RCD) and one or more socket-outlets or a provision for connection. They do not incorporate overcurrent protection. They are intended for single- and two-phase systems for rated currents not exceeding 16 A for rated voltages not exceeding 250 V AC, or for rated current not exceeding 32 A for rated voltages not exceeding 130 V AC to earth. They are intended to provide protection against shock hazard in case of direct contact, in addition to the protection provided by the fixed installations for the circuit downstream.
This second edition cancels and replaces the first edition published in 1997 and its Amendment 1:1998. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) The content of the document was revised and aligned with IEC 60755 (group safety publication for residual current devices) and standard library "blocks and modules".
b) Introduction of classification "4.3 According to behaviour after opening automatically in case of failure of the line voltage".
c) New requirements and tests were added to cover the introduced protection function against shock hazard:
- Verification of correct performance in the case of missing protective conductor.
- Verification of correct performance in the case of hazardous live protective conductor.
- Verification of correct performance in the case of loss of protective conductor.
- Verification of behaviour in the case of external fault current in the protective conductor.
d) Clearances/creepage distances revised and modified in alignment with IEC 62752 (IC‑CPD).
e) Revision of values for minimum operating voltages.
f) Introduction of requirements and test for ambient air temperature between −25 °C and +40 °C.
g) Test of dielectric properties revised and aligned with standard library "blocks and modules".
h) Relevant clauses aligned with IEC 62752 (IC-CPD); IC-CPD is a product standard describing similar product/features.
i) All annexes revised and adapted to content of main document.

  • Standard
    294 pages
    English and French language
    sale 15% off

This European Standard deals with the safety of electric drives for garage doors for residential use that open and close in a vertical direction, the rated voltage of the drives being not more than 250 V for single-phase appliances and 480 V for other appliances.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric drives for horizontally and vertically moving gates, doors, garage doors and windows for household and similar purposes, their rated voltage being not more than 250 V for single-phase drives and 480 V for other drives. It also covers the hazards associated with the movement of the driven part.

  • Amendment
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60335-2-97:2016 deals with the safety of electric drives for shutters, blinds and awnings, intended for household and similar purposes, their rated voltage being not more than 250 V for single-phase drives and 480 V for other drives. Battery-operated drives and other d.c. supplied drives are within the scope of this standard. Examples of equipment that can be driven are:
- spring controlled folding arm awnings;
- curtains;
- grilles covering doors and windows;
- projection screens;
- shutters covering doors and windows and draperies. Drives may be supplied with a driven part. Drives not intended for normal household use but that nevertheless may be a source of danger to the public, such as drives intended to be used by laymen in shops, in light industry, on farms and on industrial premises, are within the scope of this standard. Attention is drawn to the fact that for drives intended to be used in vehicles or on board ships or aircraft, additional requirements may be necessary. This standard does not apply to
- drives intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas);
- drives for vertically moving garage doors for residential use (IEC 60335-2-95);
- drives for rolling doors (IEC 60335-2-103);
- drives used in premises such as hangars or in heavy industry and drives for theatre curtains. As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home. However, in general, it does not take into account:
- persons (including children) whose physical, sensory or mental capabilities or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction or
- children playing with the appliance. This third edition cancels and replaces the second edition published in 2002 including its Amendment 1 (2004) and its Amendment 2 (2008). It constitutes a technical revision. The principal changes in this edition as compared with the second edition of IEC 60335-2-97 are as follows (minor changes are not listed):
- Deleted "rolling" from the title and modified the scope to cover appliance types other than shutters, awnings, and blinds that are operated in a rolling way;
- Revised 19.13 to allow drives to obtain a safe position;
- Added 19.101 to provide a new abnormal test for drives with rated operating time;
- Added 20.104.4 to establish a test intended to cover horizontal movement (non-rolling) drive parts;
- Added 20.104.5 to provide an additional test to cover rolling grills to address the risk of being lifted;
- Modified 22.46 and Annex R to introduce software requirements for programmable electronic circuits used to comply with Clause 20;
- Added 22.101 to introduce a requirement to prevent inadvertent adjustments that would lead to unsafe application of drives;
- Added examples of swing shutters and sliding shutters in Figure 101. The attention of National Committees is drawn to the fact that equipment manufacturers and testing organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this standard be adopted for implementation nationally not earlier than 12 months or later than 36 months from the date

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric drives for horizontally and vertically moving gates, doors, garage doors and windows for household and similar purposes, their rated voltage being not more than 250 V for single-phase drives and 480 V for other drives. It also covers the hazards associated with the movement of the driven part.

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric drives for shutters, blinds and awnings, intended for household and similar purposes, their rated voltage being not more than 250 V for single-phase drives and 480 V for other drives

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60335-2-103:2015(E) deals with the safety of electric drives for horizontally and vertically moving gates, doors, garage doors and windows for household and similar purposes, their rated voltage being not more than 250 V for single-phase drives and 480 V for other drives. It also covers the hazards associated with the movement of the driven part. Battery-operated drives and other d.c. supplied drives are within the scope of this standard. Dual supply drives, either mains-supplied or battery-operated, are regarded as battery-operated drives when operated in the battery mode. Drives not intended for normal household use but which nevertheless may be a source of danger to the public, such as drives intended to be used by laymen in shops, offices, hotels, restaurants, hospitals, in industry and on farms, are within the scope of this standard.
Requirements for drives for doors that may be used in emergency routes and exits are given in Annex AA. Examples of drives within the scope of this standard are drives for:
- folding doors;
- revolving doors;
- rolling doors;
- roof windows;
- sectional overhead doors;
- swinging and sliding gates or doors. As far as is practicable, this standard deals with the common hazards presented by drives that are encountered by all persons in and around the home. However, in general, it does not take into account persons (including children) whose physical, sensory or mental capabilities; or lack of experience and knowledge prevents them from using the drive safely without supervision or instruction or children playing with the drive. It was established on the basis of the fifth edition (2010) of that standard. This third edition cancels and replaces the second edition published in 2006 and its Amendment 1 (2010). It constitutes a technical revision. The principal changes in this edition as compared with the second edition of IEC 60335-2-103 are as follows (minor changes are not listed): modification of requirements in Clause 20 by introduction of new annexes. The attention of National Committees is drawn to the fact that equipment manufacturers and testing organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this standard be adopted for implementation nationally not earlier than 12 months or later than 36 months from the date of its publication.
Key words: Drives, Gates, Doors, Windows.

  • Standard
    69 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric drives for horizontally and vertically moving gates, doors, garage doors and windows for household and similar purposes, their rated voltage being not more than 250 V for single-phase drives and 480 V for other drives. It also covers the hazards associated with the movement of the driven part.

  • Amendment
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric drives for garage doors for residential use that open and close in a vertical direction, the rated voltage of the drives being not more than 250 V for single-phase appliances and 480 V for other appliances.

  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric drives for shutters, blinds and awnings, intended for household and similar purposes, their rated voltage being not more than 250 V for single-phase drives and 480 V for other drives

  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric drives for garage doors for residential use that open and close in a vertical direction, the rated voltage of the drives being not more than 250 V for single-phase appliances and 480 V for other appliances.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric drives for garage doors for residential use that open and close in a vertical direction, the rated voltage of the drives being not more than 250 V for single-phase appliances and 480 V for other appliances.

  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric drives for shutters, blinds and awnings, intended for household and similar purposes, their rated voltage being not more than 250 V for single-phase drives and 480 V for other drives

  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60335-2-97:2016 deals with the safety of electric drives for shutters, blinds and awnings, intended for household and similar purposes, their rated voltage being not more than 250 V for single-phase drives and 480 V for other drives. Battery-operated drives and other d.c. supplied drives are within the scope of this standard. Examples of equipment that can be driven are: - spring controlled folding arm awnings; - curtains; - grilles covering doors and windows; - projection screens; - shutters covering doors and windows and draperies. Drives may be supplied with a driven part. Drives not intended for normal household use but that nevertheless may be a source of danger to the public, such as drives intended to be used by laymen in shops, in light industry, on farms and on industrial premises, are within the scope of this standard. Attention is drawn to the fact that for drives intended to be used in vehicles or on board ships or aircraft, additional requirements may be necessary. This standard does not apply to - drives intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas); - drives for vertically moving garage doors for residential use (IEC 60335-2-95); - drives for rolling doors (IEC 60335-2-103); - drives used in premises such as hangars or in heavy industry and drives for theatre curtains. As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home. However, in general, it does not take into account: - persons (including children) whose physical, sensory or mental capabilities or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction or - children playing with the appliance. This third edition cancels and replaces the second edition published in 2002 including its Amendment 1 (2004) and its Amendment 2 (2008). It constitutes a technical revision. The principal changes in this edition as compared with the second edition of IEC 60335-2-97 are as follows (minor changes are not listed): - Deleted "rolling" from the title and modified the scope to cover appliance types other than shutters, awnings, and blinds that are operated in a rolling way; - Revised 19.13 to allow drives to obtain a safe position; - Added 19.101 to provide a new abnormal test for drives with rated operating time; - Added 20.104.4 to establish a test intended to cover horizontal movement (non-rolling) drive parts; - Added 20.104.5 to provide an additional test to cover rolling grills to address the risk of being lifted; - Modified 22.46 and Annex R to introduce software requirements for programmable electronic circuits used to comply with Clause 20; - Added 22.101 to introduce a requirement to prevent inadvertent adjustments that would lead to unsafe application of drives; - Added examples of swing shutters and sliding shutters in Figure 101. The attention of National Committees is drawn to the fact that equipment manufacturers and testing organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this standard be adopted for implementation nationally not earlier than 12 months or later than 36 months from the date

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric drives for shutters, blinds and awnings, intended for household and similar purposes, their rated voltage being not more than 250 V for single-phase drives and 480 V for other drives

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The contents of the corrigendum of March 2023 have been included in this copy.

  • Standard
    52 pages
    English and French language
    sale 15% off

IEC 62606:2013 applies to arc fault detection devices (AFDD) for household and similar uses in a.c. circuits. An AFDD is designed by the manufacturer:
- either as a single device having opening means able to open the protected circuit in specified conditions; or
- as a single device integrating a protective device; or
- as a separate unit, according to Annex D assembled on site with a declared protective device. The contents of the corrigendum of November 2013 have been included in this copy.

  • Standard
    329 pages
    English and French language
    sale 15% off
  • Standard
    693 pages
    English and French language
    sale 15% off
  • Standard
    712 pages
    English and French language
    sale 15% off

IEC 63044-5-1:2017 is a product family standard that sets the minimum level of EMC performance for the HBES/BACS network in addition to the product EMC standards for HBES/BACS devices. It also applies to devices used within an HBES/BACS network for which no specific HBES/BACS product EMC standard exists. In addition, it defines EMC requirements for the interface of equipment intended to be connected to an HBES/BACS network. It does not apply to interfaces to other networks.
NOTE An example of other networks is a dedicated ICT network covered by CISPR 22 and 23.
This document provides general performance requirements and test set-ups. This document is applicable (but not limited) to
operator stations and other human–system interface devices,
devices for management functions,
control devices, automation stations and application-specific controllers,
field devices and their interfaces,
cabling and interconnection of devices,
used within a dedicated HBES/BACS network.

  • Standard
    40 pages
    English and French language
    sale 15% off
  • Standard
    75 pages
    English and French language
    sale 15% off

IEC 63044-5-2:2017 is a product family standard that sets the minimum level of EMC performance for the HBES/BACS network in addition to the product EMC standards for HBES/BACS devices. It also applies to devices used within an HBES/BACS network for which no specific HBES/BACS product EMC standard exists. In addition, it defines EMC requirements for the interface of equipment intended to be connected to an HBES/BACS network. It does not apply to interfaces to other networks.
NOTE An example of other networks is a dedicated ICT network covered by CISPR 22 and 23.
This document specifies EMC requirements for HBES/BACS to be installed in residential, commercial and light-industrial environments, according to the definition given in IEC 61000-6-1.
This document is applicable (but not limited) to
operator stations and other human–system interface devices,
devices for management functions,
control devices, automation stations and application-specific controllers,
field devices and their interfaces,
cabling and interconnection of devices,
used within a dedicated HBES/BACS network. This publication is to be read in conjunction with IEC 63044-5-1:2017.

  • Standard
    25 pages
    English and French language
    sale 15% off
  • Standard
    56 pages
    English and French language
    sale 15% off

IEC 63044-5-3:2017 is a product family standard that sets the minimum level of EMC performance for the HBES/BACS network in addition to the product EMC standards for HBES/BACS devices. It also applies to devices used within an HBES/BACS network for which no specific HBES/BACS product EMC standard exists. In addition, it defines EMC requirements for the interface of equipment intended to be connected to an HBES/BACS network. It does not apply to interfaces to other networks.
NOTE An example of other networks is a dedicated ICT network covered by CISPR 22 and 23.
This document specifies EMC requirements for HBES/BACS to be installed in industrial environments, according to the definition given in IEC 61000-6-2.
NOTE Industrial environment covers the office spaces that may be present in industrial premises. Industrial automation systems are outside the scope. This document is applicable (but not limited) to
operator stations and other human–system interface devices,
devices for management functions,
control devices, automation stations and application-specific controllers,
field devices and their interfaces,
cabling and interconnection of devices,
used within a dedicated HBES/BACS network. This publication is to be read in conjunction with IEC 63044-5-1:2017.

  • Standard
    16 pages
    English and French language
    sale 15% off
  • Standard
    32 pages
    English and French language
    sale 15% off

IEC TR 63044-2:2022(E) provides the environmental conditions for HBES/BACS devices, when declared in the manufacturer's documentation for use in one or more of the environment classes as defined in Clause 6 of this document.

  • Technical report
    17 pages
    English language
    sale 15% off

2018-12-06: BT decision D161/C048: BT agreed to remove link to Machinery Directive (2006/42/EC) and to proceed to finalization and publication
2017-11-21 - Negative assessment is received during CDV stage. Consultant assessment request is missing for FDIS.

  • Amendment
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day