This part 2-4 of the EN IEC 61084 series specifies particular requirements and tests for service poles and service posts intended to be mounted in free space and in contact with mounting surface(s) only at one or two ends, where the word "mounted" means fixed or placed on the floor with a weighted base or linked to a mounting surface through a flexible component.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part 2-2 of the EN IEC 61084 series specifies particular requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for mounting underfloor, flushfloor or onfloor.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part 1 of the EN IEC 61084 series specifies general requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V AC and 1 500 V DC.

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Common modifications for the adoption as a European Standard of IEC 61084-2-4:2017 ed 2.0 (PR=72103)

  • Amendment
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part 2-1 of the EN IEC 61084 series specifies particular requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for intended for mounting on walls and ceilings. They can be embedded, installed in a flush or semi-flush state, surface mounted or mounted away from the surface using fixing devices.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Common modifications for the adoption as a European Standard of IEC 61084-1:2017 ed 2.0 (PR= 69866).

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part 2-3 of the EN IEC 61084 series specifies particular requirements and tests slotted cable trunking systems intended for mounting inside cabinets in electrical and/or communication system installations.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies particular requirements and tests for conduit systems buried underground for the protection and management of insulated conductors and/or power cables or communication cables that are installed by different techniques, for example, blowing (including floating), pulling or pushing directly after installation of the conduit or during its expected performance time. This standard is applicable to all conduits with circular cross section manufactured individually or manufactured as a part of an assembly NOTE Reference is made to other documents for additional material requirements where applicable.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides test methods for the measurement of the following electromagnetic characteristics of lengthwise cable management systems like conduit systems according to EN 61386 series, cable trunking systems and cable ducting systems (CTS/CDS) according to EN 50085 series and cable tray and cable ladder systems according to EN 61537: - shielding effectiveness of magnetic field, - transfer impedance. This document also provides guidance on how these characteristics can be declared and may be used.

  • Technical specification
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62275:2018 specifies requirements for metallic, non-metallic and composite cable ties and their associated fixing devices used for the management and support of wiring systems in electrical installations. This third edition cancels and replaces the second edition published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) consideration of adhesive fixing devices, b) revised and updated normative references, c) modified definitions for metallic and composite cable ties, d) new definitions, e) improvement of test procedures, f) new figures for typical arrangement of test assembly for fixing devices and for integral fixing devices.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method for the determination of the content of halogens in Cable Management System (CMS) products or system components made completely or partly of combustible material(s). The determination is made by combustion and subsequent analysis of the combustion product by Ion Chromatography. This document specifies how CMS products or system components can be declared as halogen free. This document is for environmental performance only. Compliance with this document does not imply the absence of toxicity, corrosivity or opacity of produced smoke, or other reaction to fire characteristics. If any of these characteristics are to be evaluated, the appropriate standards can be used.

  • Amendment
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies test methods for cable management systems intended (CMS) to provide support for intrinsic fire-resistant cables in order to determine their abilities to maintain the function of electrical power cables and signal/control cables for a specified duration when subjected to fire under defined conditions. This document establishes a non-hierarchical classification for this ability. Additional devices to fix the cable management systems providing fire resistant support (CMS-support) to the building structure for example screws, anchors etc. are not covered by this document. CMS intended to provide support and fire protection for cables are tested according to EN 1366 11. This document does not apply to powertrack systems. NOTE Rules for testing CMS-support for fibre optic cables and communication cables are under consideration.

  • Technical report
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63355:2022 specifies a method for the determination of the content of halogens in cable management system (CMS) products or system components made completely or partly of combustible material(s). The determination is made by combustion and subsequent analysis of the combustion product by ion chromatography. This document specifies how CMS products or system components can be declared as halogen-free.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2018-11-02 - assessment is now 'compliant', BT route to be followed to adress annex ZZ
2018-08-13: non complinat assessment
2018-05-18 - Sent to HAS
2018-03-22 - TC request to BT to keep ratification pending until Annex ZZ is available
(TC213 Plenary decision to prepare Annex ZZ and associated risk assessment for submission to CCMC and to update BT (See Decision 2 in TC213/Sec1214/RM).
2017-05-16 - Cannot allocate for publication due to missing assessment from Consultant.
2016-12-12 - Annex ZZ delivered by TC and to be sent to Consultant when FDIS starts and included in lt file for NC's voting period.

  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements and tests for conduit systems with circular cross section buried underground for the protection and management of insulated conductors and/or power cables or communication cables installed individually or installed as a part of an assembly where the cable is installed by pulling or pushing. This document does not include requirements for leak-tightness according to EN ISO 13259 and performance time. NOTE 1 EN 50626 2 specifies requirements and tests for performance time and leak-tightness for solid wall conduit systems made of PE, PP and PVC-U buried underground where the cables are installed by blowing or floating or conduits are installed by trenchless methods. NOTE 2 It is the responsibility of the purchaser or specifier to take into account any relevant national regulations and installation practices or codes when selecting the products to be installed, based on the characteristics specified in this document.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies requirements and tests for cable cleats used for securing cables in electrical installations and for intermediate restraints used for holding cables together in formation in electrical installations. Cable cleats provide resistance to electromechanical forces where declared. This document includes cable cleats that rely on a mounting surface specified by the manufacturer for axial and/or lateral retention of cables. Various types of cable cleats and intermediate restraints are shown in Annex A. NOTE Requirements for manufacturers in this document also apply to importers and responsible vendors where appropriate. This document does not apply to cable ties.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Not available

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-07-20: This prAA represents common mods to EN 61534-22:2014/prA1 (PR=72289)

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-07-20: This prAA represents common mods to EN 61534-21:2014/prA1 (PR=72286)

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2021-04-20: amdt to allow citation of main standard - when pos assessed to request BT approval

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2021-12-15: formal rejection from EC, link 'candidate for citation' temporary removed
2020-05-22: This prAA represents common mods to prEN IEC 61386-23 (PR=71030)
2021-05-07: on hold in order to incorporate SNCs
2021-06-21: SNCs approved by BT, ready for publication

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Clause 1 of IEC 61386-1:2008 is applicable, except as follows: Addition: This part of IEC 61386 specifies the requirements for pliable conduit systems including self-recovering conduit systems.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Clause 1 of IEC 61386-1:2008 is applicable, except as follows: Addition: This part of IEC 61386 specifies the requirements for flexible conduit systems.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2021-12-15: formal rejection from EC, link 'candidate for citation' temporary removed
2020-05-22: This prAA represents common mods to prEN IEC 61386-22 (PR=71035)
20210507: on hold in order to incorporate SNCs
20210618: SNCs approved, document ready for publication

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2021-12-15: formal rejection from EC, link 'candidate for citation' temporary removed
2020-05-22: This prAA represents common mods to prEN IEC 61386-21 (PR=71028)
2021-05-07: on hold in order to incorporate SNCs
2021-06-18: SNC approved, ready for publication

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Clause 1 of IEC 61386-1:2008 is applicable, except as follows: Addition: This part of IEC 61386 specifies the requirements for rigid conduit systems.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies general requirements and tests for powertrack (PT) systems with a rated voltage not exceeding 277 V a.c. single phase, or 480 V a.c. two or three phase 50 Hz/60 Hz with a rated current not exceeding 63 A. These systems are used for distributing electricity in household, commercial and industrial premises.

  • Amendment
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEXT ACTION: TB ACTION
2020-07-01: TC 213 request to delay ratification until A11 is available
2019-09-23 PeC: LVD "lack of compliance"
2019-08-27 PeC: sent for LVD assessment

  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for the determination of the content of halogens in Cable Management System (CMS) components or products made of polymeric material(s). The determination is made by combustion and subsequent analysis of the combustion product by Ion Chromatography. This standard specifies how CMS components or products can be declared as halogen free. This European Standard is for environmental performance only. Compliance with this standard does not imply the absence of toxicity, corrosivity or opacity of produced smoke, or other reaction to fire characteristics. If any of these characteristics are to be evaluated, the appropriate standards can be used. The detection limit of this test method is typically 0,025 g of halogen per kg (0,002 5 %). Halides insoluble in aqueous solution present in the original sample or produced during the combustion step are not determined by this method.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document establishes the requirements and tests for cover plates and cover tapes used for the mechanical protection, identification and warning of the location of buried cables or buried conduits. NOTE This document does not apply to meshes and tapes falling under EN 12613.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61534 specifies general requirements and tests for powertrack (PT) systems with a rated voltage not exceeding 277 V a.c. single phase, or 480 V a.c. two or three phase 50 Hz/60 Hz with a rated current not exceeding 63 A. These systems are used for distributing electricity in household, commercial and industrial premises.

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61534-22:2014 specifies the particular requirements and tests for PT systems intended for mounting on, or under the floor level and floor service units which are mounted on the floor, under the floor or flush with the floor. This second edition cancels and replaces the first edition published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Clauses 18 to 22 have been adapted to IEC 61534-1:2011 and include short-circuit test requirements; - addition of a new (500 N) classification for the resistance to traffic load applied to small surface areas on a flushfloor service unit; - addition of a new classification for the non-automatic closing of the lid on flushfloor service units and appropriate tests; - addition of tests for floor service units declared for use when a floor is wet treated. This publication is to be read in conjunction with IEC 61534-1:2011.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61534-21:2014 specifies the particular requirements and tests for PT systems intended for mounting on walls and/or ceiling. They may be installed flush or semi-flush, surface mounted, suspended or spaced away from the surface using fixing devices. This second edition cancels and replaces the first edition published in 2006 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Clauses 18 to 22 have been adapted to IEC 61534-1:2011 and include short-circuit test requirements; - Additional classification, terms and requirements for wall powertrack (PT) systems mounted at the skirting level (close to the floor) position. This publication is to be read in conjunction with IEC 61534-1:2011.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2013-04-17 - Publication editing allocated to cpalagi@cencenelec.eu
2021: CLC legacy converted by DCLab NISOSTS

  • Amendment
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62549:2011 specifies requirements and tests for systems with adaptable linear geometry for cable guiding intended for the accommodation and retention of cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V a.c. and 1 500 V d.c. This standard does not apply to cable trunking systems, cable ducting systems, conduit systems, cable tray systems, cable ladder systems, powertrack systems, energy conveying chains or equipment covered by other standards.

  • Standard
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61386-25:2011 specifies requirements and tests for conduit fixing devices used for support and/or retention of conduit for cable management. This publication is to be read in conjunction with IEC 61386-1:2008.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Publication editing allocated to svandriessche@cencenelec.eu
2021: CLC legacy converted by DCLab NISOSTS

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61534-1:2011 specifies general requirements and tests for powertrack (PT) systems with a rated voltage not exceeding 277 V a.c. single phase, or 480 V a.c. two or three phase 50 Hz/60 Hz with a rated current not exceeding 63 A. These systems are used for distributing electricity in household, commercial and industrial premises. This second edition cancels and replaces the first edition published in 2003 and constitutes a technical revision. The main changes from the previous edition are as follows: - updated normative references (Clause 2); - changes to the number of samples to be tested (Subclause 5.3); - inclusion of a short circuit test (New Clause 18); - changes to external influences (Clause 21).

  • Standard
    71 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    71 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62444:2010 provides requirements and tests for the construction and performance of cable glands. This standard covers complete cable glands as supplied by the manufacturer or the supplier responsible for placing the product on the market. This standard does not cover cable glands for mineral insulated cables. This standard covers cable glands with IEC 60423 metric entry threads. This standard can be used as a guide for cable glands with other type of entry threads.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies requirements and tests for conduit systems buried underground including conduits and conduit fittings for the protection and management of insulated conductors and/or cables in electrical installations or in communication systems. This standard applies to metallic, non-metallic and composite systems including threaded and non-threaded entries which terminate the system.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V a.c. and 1 500 V d.c. Slotted cable trunking systems are intended for mounting inside cabinets in electrical and/or communication system installations. This European Standard does not apply to conduit systems, cable tray systems, cable ladder systems, power track systems or equipment covered by other standards. This European Standard shall be used in conjunction with EN 50085-1:2005 “Cable trunking systems and cable ducting systems for electrical installations – Part 1: General requirements” which is referred to in this document as Part 1. Wherever reference is made in this European Standard to EN 50085 1:2005 this does not apply to cable ducting systems.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V a.c. and 1 500 V d.c. Service poles and service posts are intended to be mounted in free space and in contact with mounting surface(s) only at one or two ends, where the word “mounted” means fixed or placed on the floor with a weighted base or linked to a mounting surface through a flexible component. NOTE Service poles and service posts can also be part of a CTS/CDS intended for wall or ceiling mounting covered by Part 2 1 or floor mounting covered by Part 2-2 and are then also tested according to Part 2-1 and/or Part 2-2 as appropriate. This European Standard does not apply to conduit systems, cable tray systems, cable ladder systems, powertrack systems or equipment covered by other standards. This European Standard shall be used in conjunction with EN 50085-1:2005 “Cable trunking systems and cable ducting systems for electrical installations – Part 1: General requirements” which is referred to in this document as Part 1.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Replacement: This European Standard specifies requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V a.c. and 1 500 V d.c. These systems are intended for mounting underfloor, flushfloor or onfloor. This standard does not apply to CTS/CDS which are intended to be fixed to the wall and supported by the floor. This standard does not apply to conduit systems, cable tray systems, cable ladder systems, power track systems or equipment covered by other standards. This standard shall be used in conjunction with EN 50085-1:2005, Cable trunking systems and cable ducting systems for electrical installations – Part 1: General requirements, which is referred to in this document as Part 1.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61386 specifies requirements and tests for conduit systems, including conduits and conduit fittings, for the protection and management of insulated conductors and/or cables in electrical installations or in communication systems up to 1 000 V a.c. and/or 1 500 V d.c. This second edition cancels and replaces the first edition published in 1996, and its Amendment 1 (2000), and it constitutes a technical revision. The changes to the first edition are as follows: - change to the length of the test specimen between fittings for the tensile test, - editorial and normative reference updates.

  • Standard
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Amandma A11:2011 je dodatek k standardu SIST EN 61386-22:2004
Specifies the requirements for pliable conduit systems including self-recovering conduit systems.

  • Amendment
    2 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard specifies outside diameters for conduits used in electrical installations or in communication systems and the dimensional requirements for threads. It also specifies the dimensional requirements for threads used in associated fittings. It is not applicable to extra heavy-duty electrical rigid steel conduits specified in IEC 60981. This third edition cancels and replaces the second edition published in 1993. This edition constitutes a technical revision. The following main changes have been made to the second edition: -revised figures and tables plus editorial and normative reference updates -conduit range increased to 110 mm outside diameter.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day