IEC 60092-352:2025 provides the basic requirements for the selection, installation and operating conditions of electrical cables intended for fixed electrical systems on board ships at voltages (U) up to and including Um 18/30 (36) kV, symmetrical category cables and fibre optic cables.
The reference to fixed systems includes those that are subjected to vibration (due to the movement of the ship) or movement (due to motion of the ship) and not to those that are intended for frequent flexing.
Cables subject to frequent or continual flexing use, which can withstand the mechanical stress and the environment they are exposed to, are detailed in other IEC specifications such as IEC 60227 and IEC 60245. Flexible cables are frequently used for retractable thrusters, elevators, moving decks, cranes, shore connections and other moving applications on board ships.
This fourth edition cancels and replaces the third edition published in 2005. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) modification of the part title;
b) complete review of the document and establishment of the match with all other standards from the group IEC 60092-350 to IEC 60092-379;
c) addition of terms and definitions;
d) addition of technical requirements for the installation of symmetrical category cables with transmission characteristics up to 1 000 MHz;
e) addition of the technical requirements for the installation of fibre optic cables;
f) addition of technical requirements for the installation of cables for installation between areas with and without explosive atmospheres

  • Standard
    115 pages
    English language
    sale 15% off

HD 626 applies to cables of rated voltage U0/U(Um) = 0,6/1(1,2) kV used in overhead power distribution systems mainly for public distribution, of maximum system voltage not exceeding 1,2 kV. This part (Part 1) specifies the general requirements applicable to these cables, unless otherwise specified in the particular sections of this HD.
The objects of this Harmonisation Document are:
- to standardize cables that are safe and reliable when properly used and equipped with appropriate accessories, in relation to the technical requirements of the system of which they form a part,
- to state the characteristics and manufacturing requirements which have a direct or indirect bearing on safety,
- and to specify methods for checking conformity with those requirements.

  • Standardization document
    377 pages
    English language
    sale 10% off
    e-Library read for
    1 day

HD 626 applies to cables of rated voltage U0/U(Um) = 0,6/1(1,2) kV used in overhead power distribution systems mainly for public distribution, of maximum system voltage not exceeding 1,2 kV. This part (Part 1) specifies the general requirements applicable to these cables, unless otherwise specified in the particular sections of this HD. The objects of this Harmonisation Document are: - to standardize cables that are safe and reliable when properly used and equipped with appropriate accessories, in relation to the technical requirements of the system of which they form a part, - to state the characteristics and manufacturing requirements which have a direct or indirect bearing on safety, - and to specify methods for checking conformity with those requirements.

  • Standardization document
    377 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of UV laser printable coaxial cables, 50 Ω, type WZ, for use in aircraft electrical systems at operating temperatures between −65 °C and 200 °C and specially for high frequency up to 6 GHz.
The document encloses also a reinforced cable version (code R) which is used for sensitive systems with controlled VSWR.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of post installation flexible self-wrapping fire protection sleeves for electrical cable and cable bundles, providing 360° fire protection to electrical harnesses. The sleeve assembly gives fire resistance protection to the internal electrical harness against fire for five minutes and ensures that the electrical characteristics of cables will not be degraded.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the list of product standards and common characteristics of electrical cables for use in the on-board electrical systems of aircraft at operating temperatures between -55 °C and 260 °C (except otherwise specified in product standards).

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of UV laser printable DR family, single and multicore screened (spiral) and jacketed electrical lightweight cables for use in the on-board electrical systems of aircraft, at operating temperatures between −55 °C and 260 °C. Nevertheless, if needed, −65 °C is also acceptable as shown by cold test.
It is also possible to mark these cables by qualified compatible marking.
These markings are compliant with EN 3838.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method of evaluating the performance of a cable after exposure to a thermal shock.
It is intended to be used together with EN 3475-100.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60332‑1‑2:2025 specifies the procedure for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions using a 1 kW pre-mixed flame. The apparatus is described in IEC 60332‑1‑1.
NOTE 1 Testing to IEC 60332‑1‑2 can be performed simultaneously with that to IEC 60332‑1‑3, if required.
This group safety publication focusing on test method(s) is primarily intended to be used as a product safety standard for the products mentioned in the scope, but is also intended to be used by technical committees in the preparation of standards for products similar to those mentioned in the scope of this group safety publication, in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51.
NOTE 2 The performing of this test method on a single insulated conductor or cable or optical fibre cable does not provide compliance with fire propagation requirements in relevant standards in the case that the single insulated conductor or cable or optical fibre cable is installed with or amongst other cables as a group. (See the IEC 60332‑3 series).
One of the responsibilities of a technical committee is, wherever applicable, to make use of basic safety publications and/or group safety publications in the preparation of its publications.

  • Standard
    12 pages
    English language
    sale 15% off

This document specifies the test methods to evaluate the performance of coaxial, quadrax and databus cables after the installation of plastic cable ties.
It is expected to be used together with EN 3475 100.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the dimensions, tolerances, required characteristics and the mass of an AWG 24 shielded quad cable, type KL, intended for high speed (100 Mbit/s) full duplex Ethernet networks.
Linked to this particular application, the operating temperatures of the cable are between −65 °C and 125 °C.
This cable is laser markable, this marking satisfies the requirements of EN 3838.
The characteristics impedance is 100 Ω ± 15 Ω.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies test methods for cable management systems (CMS) intended to provide support for intrinsic fire-resistant cables in order to determine their abilities to maintain the function of electrical power cables and signal/control cables for a specified duration when subjected to fire under defined conditions.
This document establishes a non-hierarchical classification for this ability.
Additional devices to fix the cable management systems providing fire resistant support (CMS-support) to the building structure for example screws, anchors etc. are not covered by this document.
CMS intended to provide support and fire protection for cables are tested according to EN 1366-11.
This document does not apply to powertrack systems.
NOTE   Rules for testing CMS-support for fibre optic cables according to EN 50582 and communication cables according to EN 50289-4-16 are under consideration.

  • Technical specification
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies test methods for cable management systems (CMS) intended to provide support for intrinsic fire-resistant cables in order to determine their abilities to maintain the function of electrical power cables and signal/control cables for a specified duration when subjected to fire under defined conditions. This document establishes a non-hierarchical classification for this ability. Additional devices to fix the cable management systems providing fire resistant support (CMS-support) to the building structure for example screws, anchors etc. are not covered by this document. CMS intended to provide support and fire protection for cables are tested according to EN 1366-11. This document does not apply to powertrack systems. NOTE Rules for testing CMS-support for fibre optic cables according to EN 50582 and communication cables according to EN 50289-4-16 are under consideration.

  • Technical specification
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61442:2023 is available as IEC 61442:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61442:2023 specifies the test methods applicable for type testing accessories for power cables with rated voltages from 3,6/6 (7,2) kV up to 18/30 (36) kV. The test methods specified in this document apply to accessories for extruded and paper insulated cables according to IEC 60502-2 and IEC 60055-1 respectively.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the list of product standards and common characteristics of electrical cables for general purpose with conductors in aluminium or copper-clad aluminium, intended for installation in aircraft electrical systems.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of UV laser printable DR family, 1 to 11 cores, taped, screened (braided) and jacketed electrical lightweight cables for use in the on-board electrical systems of aircraft, at operating temperatures between −55 °C and 260 °C. Nevertheless, if needed, −65 °C is also acceptable as shown by cold test.
It is possible to mark these cables by qualified compatible marking, in line with EN 3838.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method to measure the ability of a protective sleeve to withstand specified severities of simulated lightning strikes.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of UV laser printable electrical lightweight wires AD family for use in the on-board 115 V (phase to neutral) or 200 V (phase to phase) AC, 28 VDC electrical systems of aircraft at operating temperatures between −65 °C and 180 °C. These cables are demonstrated to be arc resistant in sizes AWG 24 to 14 (115 VDC/200 VDC).
In addition, these cables can be suitable for use at 230 VAC/400 VAC in pressurized zones only when installed to take account of possible short circuit effects.
Other electrical system configurations are the responsibility of the users.
It is also possible to mark these cables by qualified compatible marking which satisfies the requirements of EN 3838:2022.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the test methods to evaluate the wicking of wire and cable insulated with textile braid.
It is intended to be used together with EN 3475-100.

  • Standard
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of UV laser printable electrical lightweight wires ADA family for use in the on-board 115 V (phase to neutral) or 200 V (phase-to-phase) AC, 28 VDC electrical systems of aircraft at operating temperatures between −65 °C and 180 °C. These cables are demonstrated to be arc resistant in sizes AWG 26 to 14 (115 VAC/200 VAC).
In addition, these cables can be suitable for use at 230 VAC/400 VAC in pressurized zones only when installed to take account of possible short circuit effects.
Other electrical system configurations are the responsibility of the users.
It is also possible to mark these cables by qualified compatible marking which satisfies the requirements of EN 3838:2022.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies methods for measuring and calculating the coverage of protection sleeves for electrical cables and cable bundles. It is presupposed to be used together with EN 6059 100.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the characteristics of post installation flexible mechanical protection sleeves for electrical cable and cable bundles made from meta-aramid fibres and provided with a water repellent protection.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61442:2023 is available as IEC 61442:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61442:2023 specifies the test methods applicable for type testing accessories for power cables with rated voltages from 3,6/6 (7,2) kV up to 18/30 (36) kV. The test methods specified in this document apply to accessories for extruded and paper insulated cables according to IEC 60502-2 and IEC 60055-1 respectively.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60331-4:2024 specifies the test apparatus and procedure, and gives the performance requirements, including recommended flame application times and flame temperatures, for power cables of rated voltage higher than 0,6/1,0 kV up to and including 18/30 kV for maintaining circuit integrity when subject to fire and mechanical shock under specified conditions.
The test method in this document is restricted to conductor sizes up to and including 120 mm2. The test results for 120 mm2 size conductors constructions qualify larger cross-sections of the same cable construction.
In the case of preassembled three-core cables, then the complete cable is considered as tested when a complete single-core of the cable has been tested.
This document includes details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to electric power cables with a rated voltage higher than 0,6/1,0 kV up to and including 18/30 kV.
Annex A provides the method of verification of the burner and control system used for the test.
Annex B provides a choice of the recommended test apparatus.
Annex C provides, as an option, guidance for using either water spray or water jet protocols.
Annex D provides, as an option, the flame temperature of 1 000 °C, which is applicable for special applications.
Requirements are stated for an identification that can optionally be marked on the cable to signify compliance with this document.
This group safety publication focusing on the test method for circuit integrity safety for power cables of rated voltage higher than 1 kV up to and including 30 kV under fire conditions, is primarily intended to be used as a product safety standard for the products mentioned in the scope, but is also intended to be used by TCs in the preparation of publications for products similar to those mentioned in the scope of this group safety publication, in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51.
One of the responsibilities of a TC is, wherever applicable, to make use of either BSPs or GSPs, or both, in the preparation of its publications.
WARNING – The test given in this document can involve the use of dangerous voltages and temperatures. Suitable precautions should be taken against the risk of shock, burning, fire and explosion that can arise, and against any noxious fumes that can be produced.

  • Standard
    29 pages
    English language
    sale 15% off

IEC 60092-378:2024 is applicable to shipboard and offshore optical fibre cables, intended for fixed installations.
Cables designed to maintain functional integrity during fire given in 6.1 and to be installed in explosive atmospheres given in 6.2 are included.
The various types of optical fibre cables are given in Clause 6. The constructional requirements and test methods are aligned with those indicated in IEC 60092‑350, unless otherwise specified in this document.

  • Standard
    19 pages
    English language
    sale 15% off

This standard specifies design, dimensions and test requirements for halogen-free cables with extruded insulation and sheath having a voltage rating of up to and including 450/750 V for flexible applications under severe condition for the power supply between the electricity supply point or the charging station and the electric vehicle (EV).
The EV charging cable is intended to supply power and if needed communication (details see EN 61851 1 and the EN 62196 series) to an electric vehicle. The charging cables are applicable for charging modes 1-3 of EN 61851 1. The cables in this standard with rated voltage 300/500 V are only permitted for charging mode 1 of EN 61851 1.
The maximum conductor operating temperatures for the cables in this standard is 90 °C.
The cables may be:
a)   an integral part of the vehicle (case A of EN 61851 1); or
b)   a detachable cable assembly with a vehicle connector and AC supply connection to a socket outlet (case B of EN 61851 1); or
c)   permanently attached to a fixed charging point (case C of EN 61851 1).
This standard describes cables whose safety and reliability is ensured when they are installed and/or used in accordance to the guide to use EN 50565 1 and Annex B

  • Amendment
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies design, dimensions and test requirements for halogen-free cables with extruded insulation and sheath having a voltage rating of up to and including 450/750 V for flexible applications under severe condition for the power supply between the electricity supply point or the charging station and the electric vehicle (EV). The EV charging cable is intended to supply power and if needed communication (details see EN 61851 1 and the EN 62196 series) to an electric vehicle. The charging cables are applicable for charging modes 1-3 of EN 61851 1. The cables in this standard with rated voltage 300/500 V are only permitted for charging mode 1 of EN 61851 1. The maximum conductor operating temperatures for the cables in this standard is 90 °C. The cables may be: a) an integral part of the vehicle (case A of EN 61851 1); or b) a detachable cable assembly with a vehicle connector and AC supply connection to a socket outlet (case B of EN 61851 1); or c) permanently attached to a fixed charging point (case C of EN 61851 1). This standard describes cables whose safety and reliability is ensured when they are installed and/or used in accordance to the guide to use EN 50565 1 and Annex B

  • Amendment
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60228:2023 specifies the nominal cross-sectional areas, in the range 0,5 mm2 to 3 500 mm2, for conductors in electric power cables and cords of a wide range of types. Requirements for numbers and sizes of wires and resistance values are also included. These conductors include solid, stranded and Milliken, copper, aluminium and aluminium alloy conductors in cables for fixed installations and flexible copper conductors. This document does not apply to conductors for telecommunication purposes. The applicability of this document to a particular type of cable is as specified in the standard for the type of cable. Unless specified otherwise in a particular clause, IEC 60028 ED4 relates to the conductors in the finished cable and not to the conductor as made or supplied for inclusion into a cable. Conductors described in this document are specified in metric sizes. Informative annexes provide supplementary information covering temperature correction factors for resistance measurement (Annex B) and guidance on dimensional limits of circular conductors (Annex C). This document has the status of a horizontal publication in accordance with IEC Guide 108.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the general characteristics, conditions for qualification, acceptance and quality assurance for a fibre optic cable with a 50/125 µm Graded Index fibre core, 1,8 mm outside diameter for non-pull-proof contact designs.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60228:2023 specifies the nominal cross-sectional areas, in the range 0,5 mm2 to 3 500 mm2, for conductors in electric power cables and cords of a wide range of types. Requirements for numbers and sizes of wires and resistance values are also included. These conductors include solid, stranded and Milliken, copper, aluminium and aluminium alloy conductors in cables for fixed installations and flexible copper conductors. This document does not apply to conductors for telecommunication purposes. The applicability of this document to a particular type of cable is as specified in the standard for the type of cable. Unless specified otherwise in a particular clause, IEC 60028 ED4 relates to the conductors in the finished cable and not to the conductor as made or supplied for inclusion into a cable. Conductors described in this document are specified in metric sizes. Informative annexes provide supplementary information covering temperature correction factors for resistance measurement (Annex B) and guidance on dimensional limits of circular conductors (Annex C). This document has the status of a horizontal publication in accordance with IEC Guide 108.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60092-379:2024 is applicable to shipboard and offshore units Ethernet (category) cables with extruded solid or foamed insulation, intended for fixed installations. Cables designed to maintain functional integrity during fire as specified in 6.1 and to be installed in explosive atmospheres as specified in 6.2 are included. The various types of Ethernet (category) cables are given in Clause 4. The constructional requirements and test methods are aligned with those indicated in IEC 60092-350, unless otherwise specified in this document.

  • Standard
    19 pages
    English language
    sale 15% off

IEC 60287-2-3:2024 describes a method for calculating the continuous current rating factor for cables of all voltages installed in ventilated tunnels. The method is applicable to any type of cable. The method applies to natural as well as forced ventilation. Longitudinal heat transfer within the cables and the surroundings of the tunnel is assumed to be negligible. All cables are assumed to be identical within the tunnel and it is assumed that the tunnel cross-section does not change with distance along the tunnel.

  • Standard
    25 pages
    English language
    sale 15% off
  • Standard
    54 pages
    English language
    sale 15% off

This document covers the construction, requirements and particular test methods for flat, flexible PVC or halogen-free insulated and sheathed cables, of rated voltage Uo/U 300/500 V and above 1 mm2, Uo/U 450/750 V for use in passenger and goods lifts (elevators), and Uo/U 450/750 V for general purposes and for special applications such as hoists and travelling cranes.
NOTE 1   This revision is in accordance with an agreement with CEN TC 10 to specify in the same standard a) flexible cables for lifts as required by EN 81-series, and b) flexible cable for applications such as hoists and travelling cranes, previously found in HD 359. In accordance with this agreement, only those cables in Clauses 5 and 6 are suitable for use with EN 81-series.
NOTE 2   The limits for the overall diameter of the cables have been calculated in accordance with EN 60719.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document covers the construction, requirements and particular test methods for flat, flexible PVC or halogen-free insulated and sheathed cables, of rated voltage Uo/U 300/500 V and above 1 mm2, Uo/U 450/750 V for use in passenger and goods lifts (elevators), and Uo/U 450/750 V for general purposes and for special applications such as hoists and travelling cranes. NOTE 1 This revision is in accordance with an agreement with CEN TC 10 to specify in the same standard a) flexible cables for lifts as required by EN 81-series, and b) flexible cable for applications such as hoists and travelling cranes, previously found in HD 359. In accordance with this agreement, only those cables in Clauses 5 and 6 are suitable for use with EN 81-series. NOTE 2 The limits for the overall diameter of the cables have been calculated in accordance with EN 60719.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60092-353:2024 is applicable to shipboard and offshore non radial field power cables with extruded solid insulation, having a voltage rating of 0,6/1 (1,2) kV or 1,8/3 (3,6) kV intended for fixed installations. Cables designed to maintain circuit integrity during a fire are included. The various types of power cables are given in 5.1. The constructional requirements and test methods are aligned with those indicated in IEC 60092-350, unless otherwise specified in this document.
The object of this document is:
- to standardize cables whose safety and reliability is ensured when they are installed in accordance with the requirements of IEC 60092-352 or IEC 61892-4,
- to lay down standard manufacturing requirements and characteristics of such cables directly or indirectly bearing on safety, and
- to specify test methods for checking conformity with those requirements.
This fifth edition cancels and replaces the fourth edition published in 2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Updated references to IEC 60092-350 for general construction and test methods and IEC 60092-360 for insulating and sheathing materials.
b) Added subclause 5.10: Construction for special applications.
c) Added Table 9: Additional test for cables for installation between areas with and without explosive atmospheres.
d) Deleted the test requirement IEC 60331-21 from Table 7.
e) Deleted the former Annex A (Alternative enhanced insulation thickness for 0,6/1 kV).

  • Standard
    21 pages
    English language
    sale 15% off
  • Standard
    43 pages
    English language
    sale 15% off

IEC 60502-2:2014 specifies the construction, dimensions and test requirements of power cables with extruded solid insulation from 6 kV up to 30 kV for fixed installations such as distribution networks or industrial installations. When determining applications, it is recommended that the possible risk of radial water ingress is considered. Cable designs with barriers claimed to prevent longitudinal water penetration and an associated test are included in this part of IEC 60502. Cables for special installation and service conditions are not included, for example cables for overhead networks, the mining industry, nuclear power plants (in and around the containment area) nor for submarine use or shipboard application. This third edition cancels and replaces the second edition, published in 2005, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) a simplified calculation procedure for the thickness of the lead sheath and the oversheath;
b) a new subclause for the determination of the cable conductor temperature;
c) a modified procedure for the routine voltage test;
d) a new subclause for a routine electrical test on oversheath;
e) modified requirements for the non-metal sheaths including semi-conductive layer;
f) modified tolerances for the bending test cylinder;
g) the inclusion of a 0,1 Hz test after installation.
In addition, the modified structure of the IEC 60811 series has been adopted for this third edition.

  • Standard
    87 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    195 pages
    English language
    sale 15% off
  • Standard
    265 pages
    English language
    sale 15% off
  • Standard
    176 pages
    English and French language
    sale 15% off

This document specifies the dimensions, tolerances, required characteristics and the mass of an
AWG 24 shielded quad cable, type KD, intended for high speed (100 Mbit/s) full duplex Ethernet
networks.
Linked to this particular application, the operating temperatures of the cable are between −65 °C and
125 °C.
The cable resists a long-term temperature between −65 °C and +200 °C.
Moreover, cable materials are compatible with 200 °C peak exposure.
This cable is laser markable, this marking satisfies the requirements of EN 3838.
The characteristics impedance is (100 ± 15) Ω.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60227-7:2024 details the particular specifications for polyvinyl chloride insulated, screened and unscreened control cables of rated voltages up to and including 300/500 V. This document provides the particular requirements for screened and unscreened control cables of rated voltages up to and including 300/500 V, which apply in addition to the appropriate requirements specified in IEC 60227-1, which apply to all cables. The tests for cables specified in the IEC 60227 series are described in IEC 63294.

  • Standard
    15 pages
    English language
    sale 15% off
  • Standard
    32 pages
    English language
    sale 15% off

IEC 60227-3:2024 details the particular standards for polyvinyl chloride insulated single-core non-sheathed cables for fixed wiring of rated voltages up to and including 450/750 V. This document provides the particular requirements for non-sheathed cables for fixed wiring which apply in addition to the appropriate requirements specified in IEC 60227-1, which apply to all cables. The tests for cables specified in the IEC 60227 series are described in IEC 63294.

  • Standard
    22 pages
    English language
    sale 15% off
  • Standard
    44 pages
    English language
    sale 15% off

IEC 60227-5:2024 details the particular specifications or polyvinyl chloride insulated flexible cables (cords), of rated voltages up to and including 300/500 V. This document provides the particular requirements for flexible cables (cords) which apply in addition to the appropriate requirements specified in IEC 60227-1, which apply to all cables. The tests for cables specified in the IEC 60227 series are described in IEC 63294.

  • Standard
    28 pages
    English language
    sale 15% off
  • Standard
    59 pages
    English language
    sale 15% off

IEC 60227-1:2024 applies to rigid and flexible cables with insulation, and sheath if any, based on polyvinyl chloride, of rated voltages Uo/U up to and including 450/750 V used in power installations of nominal voltage not exceeding 450/750 V AC.
NOTE For some types of flexible cables the term "cord" is used.
The particular types of cables are specified in IEC 60227-3, IEC 60227-4, IEC 60227-5, IEC 60227-6 and IEC 60227-7. The code designations of these types of cables are provided in this document. The test methods specified in this document, IEC 60227-3, IEC 60227-4, IEC 60227-5, IEC 60227-6 and IEC 60227-7 are given in IEC 63294, IEC 60332-1-2 and in the relevant parts of the IEC 60811 series.

  • Standard
    23 pages
    English language
    sale 15% off
  • Standard
    47 pages
    English language
    sale 15% off

IEC 60227-4:2024 details the particular specifications for light polyvinyl chloride sheathed cables of rated voltages of 300/500 V.
This document provides the particular requirements for sheathed cables for fixed wiring which apply in addition to the appropriate requirements specified in IEC 60227-1, which apply to all cables.
The tests for cables specified in the IEC 60227 series are described in IEC 63294.

  • Standard
    12 pages
    English language
    sale 15% off

1.1   General
This document specifies performance requirements for type tests for cable accessories for use on impregnated paper insulated power cables as specified in HD 621.
It is not necessary to repeat these tests, once successfully completed, unless changes are made in the materials, design or manufacturing process, which might affect the performance characteristics.
Accessories for special applications such as submarine cables, ships cables or hazardous situations (explosive environments, fire resistant cables or seismic conditions) are not included.
Test methods are included in EN 61442:2005.
NOTE   It might be possible, subject to agreement between supplier and purchaser, and/or the relevant conformity assessment body, to demonstrate that conformity to the earlier standard can be used to claim conformity to this document, provided an assessment is made of any additional type testing that might need to be carried out. Any such additional testing that is part of a sequence of testing cannot be done separately.
1.2   Type of accessories
The accessories covered by this document are listed below:
-   indoor and outdoor terminations of all designs, including terminal boxes;
-   straight joints, branch joints and stop end joints of all designs, suitable for use underground or in air;
-   screened or unscreened plug-in type or bolted-type separable connectors capable of interfacing with bushing profiles as specified in EN 50180 series and EN 50181.
1.3   Rated voltage
The rated voltages U0/U(Um) of the accessories covered by this document are 3,6/6(7,2) - 3,8/6,6(7,2) - 6/10(12) - 6,35/11(12) - 8,7/15(17,5) - 12/20(24) - 12,7/22(24) - 18/30(36) - 19/33(36) - 20,8/36(42) kV.

  • Standardization document
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   General
This document specifies performance requirements for type tests for transition joints for use between extruded insulated power cables as specified in HD 620 and impregnated paper insulated power cables as specified in HD 621 or another relevant standard.
Once type test for an accessory is successfully completed, it is not necessary to repeat the test, unless changes are made in the materials, design or manufacturing process, which might affect the performance characteristics.
Possible extra thermo-mechanical forces due to high current loads from renewable sources of power generation are not covered by these tests (under consideration).
Accessories for special applications such as submarine cables, ships cables or hazardous situations (explosive environments, fire resistant cables or seismic conditions) are not included.
Test methods are included in EN IEC 61442:- and Annex E.
NOTE 1   This document does not invalidate existing approvals of products achieved on the basis of national standards and specifications and/or the demonstration of satisfactory service performance. However, products approved according to such national standards or specifications cannot directly claim approval to this document.
NOTE 2   It might be possible, subject to agreement between supplier and purchaser, and/or the relevant conformity assessment body, to demonstrate that conformity to the earlier standard can be used to claim conformity to this document, provided an assessment is made of any additional type testing that might need to be carried out. Any such additional testing that is part of a sequence of testing cannot be done separately.
1.2   Type of accessories
The accessories covered by this document are straight and branch transition joints of all designs, suitable for use underground or in air.
1.3   Rated voltage
The rated voltages U0/U (Um) of the accessories covered by this document are 3,6/6(7,2) - 3,8/6,6(7,2) - 6/10(12) - 6,35/11(12) - 8,7/15(17,5) - 12/20(24) - 12,7/22(24) - 18/30(36) - 19/33(36) - 20,8/36(42) kV.

  • Standardization document
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1 General This document specifies performance requirements for type tests for transition joints for use between extruded insulated power cables as specified in HD 620 and impregnated paper insulated power cables as specified in HD 621 or another relevant standard. Once type test for an accessory is successfully completed, it is not necessary to repeat the test, unless changes are made in the materials, design or manufacturing process, which might affect the performance characteristics. Possible extra thermo-mechanical forces due to high current loads from renewable sources of power generation are not covered by these tests (under consideration). Accessories for special applications such as submarine cables, ships cables or hazardous situations (explosive environments, fire resistant cables or seismic conditions) are not included. Test methods are included in EN IEC 61442:- and Annex E. NOTE 1 This document does not invalidate existing approvals of products achieved on the basis of national standards and specifications and/or the demonstration of satisfactory service performance. However, products approved according to such national standards or specifications cannot directly claim approval to this document. NOTE 2 It might be possible, subject to agreement between supplier and purchaser, and/or the relevant conformity assessment body, to demonstrate that conformity to the earlier standard can be used to claim conformity to this document, provided an assessment is made of any additional type testing that might need to be carried out. Any such additional testing that is part of a sequence of testing cannot be done separately. 1.2 Type of accessories The accessories covered by this document are straight and branch transition joints of all designs, suitable for use underground or in air. 1.3 Rated voltage The rated voltages U0/U (Um) of the accessories covered by this document are 3,6/6(7,2) - 3,8/6,6(7,2) - 6/10(12) - 6,35/11(12) - 8,7/15(17,5) - 12/20(24) - 12,7/22(24) - 18/30(36) - 19/33(36) - 20,8/36(42) kV.

  • Standardization document
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1 General This document specifies performance requirements for type tests for cable accessories for use on impregnated paper insulated power cables as specified in HD 621. It is not necessary to repeat these tests, once successfully completed, unless changes are made in the materials, design or manufacturing process, which might affect the performance characteristics. Accessories for special applications such as submarine cables, ships cables or hazardous situations (explosive environments, fire resistant cables or seismic conditions) are not included. Test methods are included in EN 61442:2005. NOTE It might be possible, subject to agreement between supplier and purchaser, and/or the relevant conformity assessment body, to demonstrate that conformity to the earlier standard can be used to claim conformity to this document, provided an assessment is made of any additional type testing that might need to be carried out. Any such additional testing that is part of a sequence of testing cannot be done separately. 1.2 Type of accessories The accessories covered by this document are listed below: - indoor and outdoor terminations of all designs, including terminal boxes; - straight joints, branch joints and stop end joints of all designs, suitable for use underground or in air; - screened or unscreened plug-in type or bolted-type separable connectors capable of interfacing with bushing profiles as specified in EN 50180 series and EN 50181. 1.3 Rated voltage The rated voltages U0/U(Um) of the accessories covered by this document are 3,6/6(7,2) - 3,8/6,6(7,2) - 6/10(12) - 6,35/11(12) - 8,7/15(17,5) - 12/20(24) - 12,7/22(24) - 18/30(36) - 19/33(36) - 20,8/36(42) kV.

  • Standardization document
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day