E06 - Performance of Buildings
The promotion of knowledge, stimulation of research, development and maintenance of standards and related documents for performance of buildings, their elements, components, including means and methods of fabrication and assembly; and the description, measurement, prediction, improvement, and management of the overall performance of buildings and building-related facilities. The work of this Committee will be coordinated with other ASTM Committees and other organizations having a mutual interest.
Performance of Buildings
The promotion of knowledge, stimulation of research, development and maintenance of standards and related documents for performance of buildings, their elements, components, including means and methods of fabrication and assembly; and the description, measurement, prediction, improvement, and management of the overall performance of buildings and building-related facilities. The work of this Committee will be coordinated with other ASTM Committees and other organizations having a mutual interest.
General Information
ABSTRACT
This specification covers permanent metal railing systems (such as guard, stair, and ramp-rail systems) and rails (such as hand, wall, grab, and transfer rails) for use in agricultural, assembly, commercial, educational, industrial, institutional, recreational, and residential buildings. Also covered in this specification are basic design requirements and considerations, and minimum criteria for load and deflections; however, it does not cover design criteria for specific field conditions. Railing systems and rails shall be manufactured with major structural components made of metal and secondary components made of metal, wood, plastics, or glass, and shall withstand forces that may potentially be exerted by building users. Tests for static loading and deflection shall be performed and shall conform to the requirements specified.
SIGNIFICANCE AND USE
5.1 Metal railing systems and rails for buildings usually are designed, manufactured, and installed to withstand forces potentially exerted by the building users.
5.2 The metal railing systems and rails shall not be considered a part of the structural system of the building unless this is expressly provided for in the design.
SCOPE
1.1 This specification2 covers permanent metal railing systems (guard, stair, and ramp-rail systems) and rails (hand, wall, grab, and transfer rails) installed in and for agricultural, assembly, commercial, educational, industrial, institutional, recreational, and residential buildings. However, this standard does not cover metal railing systems installed in and for industrial, commercial, and other non-residential workplace occupancies where normally only adults will be present or have access, and for which guardrail or handrail requirements are specified by occupational safety and health safety regulations and standards. This standard does not cover ballasted railing systems.
1.2 This specification is intended to be applied to permanent metal railing systems for buildings and to such railing systems and rails having major structural components made of metal, with their secondary components made of metal or other materials such as wood, plastics, and glass.
1.3 This specification considers that today's and tomorrow's overall outlook is based on the health and safety of all potential users of buildings. The criteria incorporated in this specification provide for normal and anticipated building uses, but not for abuses for which the building and its components are not designed.
1.4 This specification establishes basic minimum requirements and criteria that lead to satisfactory products under normal use conditions and does not give consideration to design criteria for specific field conditions, the establishment of which is the prerogative and responsibility of the designer, specification writer, and code agencies.
1.5 Sources of supportive information are listed in the Reference section (1-28).3
1.6 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification5 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This practice provides a standard set of procedures that are to be followed when conducting and reporting on inspections of installed fire resistive duct systems.
5.2 This practice provides a means to verify compliance of the installed fire resistive duct system to the inspection document.
5.3 This practice does not provide a basis for selecting a design listing, the installation contractor, products, or any other material, service, or company.
5.4 This practice does not establish any performance criteria of the inspected fire resistive duct systems.
SCOPE
1.1 This practice covers a standard set of procedures for inspecting and reporting on the installed fire resistive duct systems.
1.2 This practice establishes procedures to inspect products and systems, including methods for field verification and inspection.
1.3 This practice provides an inspector and inspection body, various methods to verify that required systems have been installed in accordance with the inspection document.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 The text of this standard references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard7 pagesEnglish language
ABSTRACT
This specification covers the physical requirements and movement capabilities of preformed architectural strip seals for use in sealing expansion joints in buildings and parking structures. However, this specification does not provide information on the durability of the architectural strip seals under actual service conditions, loading capability of the system, and the effects of a load on the functional parameters. Material covered by this specification consists of architectural strip seals extruded as a membrane or tubular, with frames, with flanges mechanically or chemically secured, used in interior or exterior application, and used in any construction of the building. The architectural strip seal shall be manufactured from a fully cured elastomeric alloy as a preformed extrusion free of defects such as holes and air bubbles, and with dimensions conforming to the requirements specified. Tests for tensile strength, elongation at break, hardness, ozone resistance, compression set, heat aging, tear resistance, brittleness temperature, and water absorption shall be performed and shall conform to the requirements specified.
SIGNIFICANCE AND USE
9.1 Architectural strip seals included in this specification shall be those:
9.1.1 Extruded as a membrane,
9.1.2 Extruded as tubular,
9.1.3 With frames,
9.1.4 With flanges mechanically secured,
9.1.5 With flanges chemically secured,
9.1.6 Used in interior or exterior applications, and
9.1.7 Used in any construction of the building.
9.2 This specification will give users, producers, building officials, code authorities, and others a basis for verifying material and performance characteristics of representative specimens under common test conditions. This specification will produce data on the following:
9.2.1 The physical properties of the fully cured elastomeric alloy, and
9.2.2 The movement capability in relation to the nominal joint width as defined under Test Method E1399/E1399M.
9.3 This specification compares similar architectural strip seals but is not intended to reflect the system's application. “Similar” refers to the same type of architectural strip seal within the same subsection under 9.1.
9.4 This specification does not provide information on the following:
9.4.1 Durability of the architectural strip seal under actual service conditions, including the effects of cycled temperature on the strip seal;
9.4.2 Loading capability of the system and the effects of a load on the functional parameters established by this specification;
9.4.3 Shear and rotational movements of the specimen;
9.4.4 Any other attributes of the specimen, such as fire resistance, wear resistance, chemical resistance, air infiltration, watertightness, and so forth; and
Note 3: This specification addresses fully cured elastomeric alloys. Test Methods D395, D573, D1052, and D1149 are tests better suited for evaluating thermoset materials.
9.4.5 Testing or compatibility of substrates.
9.5 This specification is intended to be used as only one element in the selection of an architectural strip seal for a particular application. It is not...
SCOPE
1.1 This specification covers the physical requirements for the fully cured elastomeric alloy and the movement capabilities of preformed architectural compression seals used for sealing expansion joints in buildings and parking structures. The preformed architectural strip seal is an elastomeric extrusion. This extrusion is either a membrane or tubular having an internal baffle system produced continuously and longitudinally throughout the material. These extrusions are secured in or over a joint by locking rails or an end dam nosing material. The architectural strip seal is compressed and expanded by this mechanical or chemical attachment.
Note 1: Movement capability is defined in Test Method E1399/E1399M.
1.2 This specification covers all colors of architectural strip seals.
No...
- Technical specification5 pagesEnglish language
- Technical specification5 pagesEnglish language
SIGNIFICANCE AND USE
6.1 This practice is used to determine the LR of specified glass types and constructions exposed to uniform lateral loads.
6.2 Use of this practice assumes:
6.2.1 The glass is free of edge damage and is properly glazed.
6.2.2 The glass has not been subjected to abuse.
6.2.3 The surface condition of the glass is typical of glass that has been in service for several years, and is weaker than freshly manufactured glass due to minor abrasions on exposed surfaces.
6.2.4 The glass edge support system is sufficiently stiff to limit the lateral deflections of the supported glass edges to no more than 1/175 of their lengths. The specified design load shall be used for this calculation.
6.2.5 The deflection of glass or support system, or both, shall not result in loss of glass edge support. The glass bite reduction or pullout shall be considered using the method referenced in (1).3
Note 2: Glass deflections are to be reviewed. This practice does not address aesthetic issues caused by glass deflection.
Note 3: This practice does not consider the effects of deflection on insulating glass unit seal performance.
Note 4: The designer/engineer must determine what constitutes sufficient glass edge support based on Annex A1, Non-Factored Load Charts.
6.3 Many other factors shall be considered in glass type and thickness selection. These factors include but are not limited to: thermal stresses, spontaneous breakage of tempered glass, the effects of windborne debris, excessive deflections, behavior of glass fragments after breakage, blast, seismic effects, building movement, heat flow, edge bite, noise abatement, and potential post-breakage consequences. In addition, considerations set forth in building codes along with criteria presented in safety-glazing standards and site-specific concerns may control the ultimate glass type and thickness selection.
6.4 For situations not specifically addressed in this standard, the design professional shall use enginee...
SCOPE
1.1 This practice covers procedures to determine the load resistance (LR) of specified glass types, including combinations of glass types used in a sealed insulating glass (IG) unit, exposed to a uniform lateral load of short or long duration, for a specified probability of breakage.
1.2 This practice applies to vertical and sloped glazing in buildings for which the specified design loads consist of wind load, snow load and self-weight with a total combined magnitude less than or equal to 15 kPa (315 psf). This practice shall not apply to other applications including, but not limited to, balustrades, glass floor panels, aquariums, structural glass members, and glass shelves.
1.3 This practice applies only to monolithic and laminated glass constructions of rectangular shape with continuous lateral support along one, two, three, or four edges. This practice assumes that (1) the supported glass edges for two, three, and four-sided support conditions are simply supported and free to slip in plane; (2) glass supported on two sides acts as a simply supported beam; and (3) glass supported on one side acts as a cantilever. For insulating glass units, this practice only applies to insulating glass units with four-sided edge support.
1.4 This practice does not apply to any form of wired, patterned, sandblasted, drilled, notched, or grooved glass. This practice does not apply to glass with surface or edge treatments that reduce the glass strength.
Note 1: Ceramic enamel is known to affect glass load resistance. Consult the manufacturer for guidance.
1.5 This practice addresses only the determination of the resistance of glass to uniform lateral loads. The final thickness and type of glass selected also depends upon a variety of other factors (see 6.3).
1.6 Charts in this practice provide a means to determine approximate maximum lateral glass deflection. Appendix X1 provides additional procedures to determine maximu...
- Standard65 pagesEnglish language
- Standard65 pagesEnglish language
ABSTRACT
This specification covers the classification, design and performance requirements, and test methods for glass in permanent railing systems, guards, and balustrades installed in agricultural, assembly, commercial, educational, industrial, institutional, recreational, and residential buildings. This specification considers that the overall outlook is based on the health and safety of all potential users of buildings, and establishes the basic minimum requirements and criteria that lead to satisfactory products under normal and anticipated building uses, and not for abuses for which the building and its components are not designed. Also, this specification does not give consideration to design criteria for specific field conditions, the establishment of which is the prerogative and responsibility of the designer, specification writer, and regulatory agencies.
SIGNIFICANCE AND USE
11.1 The significance and use of the test methods is contained in Test Methods E2353.
SCOPE
1.1 This specification covers glass in permanent railing systems, guards, and balustrades, including components such as rails and swing gates or other forms of required guardrail opening protection installed in agricultural, assembly, comme-
rcial, educational, industrial, institutional, recreational, and residential buildings, and other structures such as towers or elevated platforms.
1.2 This specification is intended to be applied to permanent glass or other glazing railing systems for buildings and to such railing systems, rails, guards, and balustrades having major structural components made of glass or other glazing material, or the secondary components such as infill or balusters made of glass or other glazing material.
1.3 This specification considers that the overall outlook is based on the health and safety of all potential users of buildings. The criteria incorporated in this specification provide for normal and anticipated building uses, but not for abuses for which the building and its components are not designed.
1.4 This specification establishes basic minimum requirements and criteria that lead to satisfactory products under normal use conditions and does not give consideration to design criteria for specific field conditions, the establishment of which is the prerogative and responsibility of the designer, specification writer, and regulatory agencies.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and to determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification6 pagesEnglish language
- Technical specification6 pagesEnglish language
SIGNIFICANCE AND USE
4.1 As the building industry shifts towards performance-based design, specification of material properties consistent with anticipated in-service conditions becomes paramount to the design process. When specifying water vapor transmission properties, it is important to identify water vapor transmission properties for WRB/AB products that are measured under test conditions relevant to anticipated in-service conditions. This guide provides a performance-based framework for characterizing the water vapor transmission properties of WRB/AB.
4.2 When specifying WRB/AB, water vapor permeance is an important attribute to consider for proper moisture management and functioning of wall and roof assemblies in service. In North America, water vapor transmission properties of water-resistive and air barrier materials are traditionally tested in accordance with Test Methods E96/E96M. This guide adopts the ASTM E96/E96M test methods as a primary source of information for water vapor transmission properties of WRB/AB unless otherwise instructed by the design professional.
4.3 Most standard test methods rely on a limited set of steady-state testing conditions for evaluating the water vapor transmission properties of materials. Test conditions used to measure and report water vapor transmission values of WRB/AB should represent the in-service conditions of the tested material as closely as possible (that is, should cover the range of temperature and relative humidity conditions the products will experience when installed in wall and roof assemblies). The water vapor permeance of many WRB/AB materials can vary by more than an order of magnitude when tested for ranges of temperatures and relative humidity expected in service. For this reason, WVT properties over the full range of environmental conditions that the material will most likely experience in service should be used or evaluated when specifying a material or assembly design for a specific project.
SCOPE
1.1 This document covers guidelines for specifying water vapor transmission (WVT) properties for above-grade water-resistive barriers and air barriers (WRB/AB), typically installed between building structural components and cladding that compose the exterior side of building envelopes in North America.
1.2 This guide applies to all types of water-resistive barrier and air barrier products, including multifunctional products, regardless of the manufacturing process, type of material, or installation technique.
1.3 This guide provides general provisions for specifying and reporting the water vapor transmission properties of WRB/AB determined by standardized test methods, in accordance with in-service conditions these products typically experience within building envelopes.
1.4 It is beyond the scope of this guide to optimize the water vapor transmission characteristics of WRB/AB for specific conditions of use. The specific conditions of use should account for variations in indoor and outdoor climates, cladding type, moisture storage capacity of cladding materials, thermal insulating measures for wall and roof assemblies, air movement, and vapor diffusion control strategies.
1.5 This guide does not address proper installation and integration of WRB/AB with other wall and roof components.
1.6 The values stated in inch-pound units are to be regarded separately as standard. Within the text, the SI units shown in parentheses are provided for information only. The values stated in each system are not exact equivalents; therefore, each system shall be used independently. Combining values from two systems may result in non-conformance with the standard. However, derived results can be converted between systems using appropriate conversion factors (see Table 1).
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish approp...
- Guide14 pagesEnglish language
- Guide14 pagesEnglish language
SCOPE
1.1 This specification covers procedures for determining whether building materials are considered flood-damage-resistant for construction intended to comply with the requirements of the National Flood Insurance Program (NFIP) (44 CFR Part 60.3(a)(3)). It was developed from and is intended to supplement specifications in Technical Bulletin 2 (TB 2) (1)2 for purposes of evaluating building materials that comply with requirements of the applicable building code that are not already recognized as acceptable in accordance with TB 2 (1).
1.2 This specification is intended to reduce the burden on the NFIP by improving the ability to construct flood-resistant buildings and structures and thereby decrease the number and magnitude of flood insurance claims. The goal is to identify materials that, when tested as part of an assembly representative of end use configuration, would be permitted for construction below the base flood elevation (BFE) and not require repair after a flood event due to adverse effects of water immersion and subsequent drying on performance.
1.3 This specification is intended to apply to building materials used in new construction, repair of substantially damaged buildings, and substantial improvement of existing buildings in special flood hazard areas (SFHAs) for construction used in non-habitable spaces below the BFE as permitted by the NFIP (44 CFR Part 60.3(a)(3)) and TB 2 (1) including, but not limited to, building materials used in foundations, walls, floors, ceilings, stairways, exterior cladding, and other similarly incorporated architectural and structural items. Evaluation of products for use in habitable spaces is outside of the scope of this specification.
1.4 This specification includes requirements for the purpose of evaluating effects of flooding on specimen physical properties, drying, and the ability to be cleaned.
1.5 The performance of a material specimen under the specified water immersion and drying conditions shall not be construed as fully representative of performance of the material for an actual flood event because actual flood conditions vary in factors such as makeup of water, and depth and duration of immersion, and drying conditions vary by factors such as ambient temperature and humidity.
1.6 Performance requirements vary based on the type of building material and the functions the building material is required to perform. The body of the specification gives general requirements applicable to a broad range of building materials with annexes provided for material-specific requirements.
1.7 Performance requirements for evaluation of other hazards associated with flood damage are outside the scope of this specification. These hazards include, but are not limited to, debris impact, flood velocity, wave action, water pressure differential, scour, erosion, varied biological contaminants in flood water including fungal matter and sewage, and chemical contaminants in floodwater, and other factors that would be adverse to continued use of the structure for its intended purpose including long-term occupant health impacts.
1.8 A commentary to this specification is provided in Appendix X1.
1.9 Units—The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are mathematical conversions to International System of Units (SI) units that are provided for information only and are not considered standard.
1.10 The text of this standard references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
1.11 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prio...
- Technical specification12 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This method is intended to simulate the performance of various air barrier materials/accessories when combined into an assembly. Based upon the results of the measurements, this procedure then assigns an air leakage rating for the air barrier assembly.
5.2 This method does not purport to establish all criteria necessary for consideration in the selection of an air barrier assembly. The results are intended to be used for comparison purposes and may not represent the field installed performance of the air barrier assembly when installed as part of an air barrier system in a building. However, the results of these tests may be useful in determining the appropriate use of a specified air barrier system assembly.
5.3 This method does not purport to establish all criteria necessary for air barrier systems of all construction types. Test Method E2178 provides an air permeance test method for testing of some air barrier materials. Specification E1677 provides a specification for air barrier systems for low-rise framed building walls.
SCOPE
1.1 This test method covers the determination of the air leakage rate of air barrier assemblies that are used in building enclosures. This procedure measures the air leakage of a representative air barrier assembly before and after exposure to specific conditioning cycles and then assigns a rating dependent upon the results. Although this is a laboratory procedure, the method may also be applied to site mockups.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard11 pagesEnglish language
- Standard11 pagesEnglish language
ABSTRACT
This specification covers the design, construction, and weatherability of structural standing seam steel roof panel systems. It includes performance requirements for the following elements only: panels, concealed panel clips, panel/clip anchorage, and panel joint sealers. Panel material shall be a hot dip metallic coated product in accordance with one of the following commonly used materials: aluminum-, aluminum-zinc alloy-, zinc-, or zinc-5% aluminum alloy metallic-coated sheet steel. The roof system shall be designed for specified design loads and thermal effects without causing seam separation, permanent panel buckling, or weather-tightness loss. Deflection and serviceability shall be accounted for in the panel system for structural integrity. Static and uplift index tests shall be performed to determine the roof's load capacity. Standing seam roof panel systems shall be installed in accordance with the system design requirements.
SCOPE
1.1 This specification covers the design, construction, and weatherability of structural standing seam steel roof panel systems. It includes performance requirements for the following elements only: panels, concealed panel clips, panel/clip anchorage, and panel joint sealers.
Note 1: These systems are used on both low-slope and steep-slope roof applications. They also are used with or without an underlying deck or sheathing.
1.2 The objective of this specification is to provide for the overall performance of the structural standing seam steel roof panel system as defined in 3.2.6 during its service life in order to provide weather protection, carry the specified design loads, and allow proper access over the roof surface in order to provide for periodic maintenance of equipment by the owner.
1.3 In addition to structural, the specifier shall evaluate other characteristics beyond the scope of this specification that affect the final choice of roof construction. These include, but are not limited to, functional, legal, insurance, and economic considerations. See Appendix X1 for specifier's checklist.
1.4 The specification is not intended to exclude products or systems not covered by the referenced documents.
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.6 The text of this specification contains notes and footnotes that provide explanatory information and are not requirements of this specification.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification5 pagesEnglish language
SIGNIFICANCE AND USE
4.1 These test methods are intended to provide information from which applicable design data and specifications are derived for a given anchorage device and for qualifying anchors or anchorage devices.
4.2 These test methods shall be followed to ensure reproducibility of the test data.
SCOPE
1.1 These test methods cover instructions for making a variety of tests for the strength of the adhesive bond developed between a steel anchor and the surface of a hole in concrete or masonry (including masonry units and mortar joints) and for assessing the effects on such bond of a variety of factors including elevated temperature, fire, moisture, and freezing and thawing action. The specifier or manufacturer shall select those tests that are appropriate for the given anchoring system and intended application.
1.2 The adhesive-bonded anchor system refers to a smooth or deformed steel bar or threaded rod, set in a predrilled hole containing chemical bonding compounds. Loads are transferred mainly by the bond of the adhesive both to the anchor and the surrounding elements along the sides of the hole. For anchoring systems made of significantly different materials, these test methods shall be taken as a guideline.
1.3 These test methods apply to all adhesives used to bond steel anchors or steel reinforcement bars (rebar) to concrete or masonry. These test methods apply to anchorages used in uncracked concrete or masonry. They do not apply to the use of the anchor in the concrete tension zone. The usual forces applied during the tests are in tension, shear, and under a combination of both tension and shear.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Air leakage between an air distribution system and unconditioned spaces affects the energy losses from the distribution system, the ventilation rate of the building, and the entry rate of air pollutants.
5.2 The determination of infiltration energy loads and ventilation rates of residences and small commercial buildings are typically based on the assumption that the principal driving forces for infiltration and ventilation are the wind and indoor/outdoor temperature differences. This can be an inappropriate assumption for buildings that have distribution systems that pass through unconditioned spaces, because the existence of relatively modest leakage from that system has a relatively large impact on overall ventilation rates. The air leakage characteristics of these exterior distribution systems are needed to determine their ventilation, energy, and pollutant-entry implications.
5.3 Air leakage through the exterior air distribution envelope may be treated in the same manner as air leakage in the building envelope as long as the system is not operating (see Test Method E779). However, when the system blower is on, the pressures across the air distribution system leaks are usually significantly larger than those driving natural infiltration. Depending on the size of the leaks, these pressures can induce much larger flows than natural infiltration. Thus, it is important to be able to isolate these leaks from building envelope leaks. The leakage of air distribution systems must be measured in the field, because it has been shown that workmanship and installation details are more important than design in determining the leakage of these systems.
5.4 For codes, standards, and other compliance or quality control applications, the precision and repeatability at meeting a specified target (for example, air flow at reference pressure) is more important than air leakage flows at operating conditions. Some existing codes, standards, and voluntary programs require ...
SCOPE
1.1 The test methods included in this standard are applicable to the air distribution systems in low-rise residential and commercial buildings.
1.2 These test methods cover four techniques for measuring the air leakage of air distribution systems. The techniques use air flow and pressure measurements to determine the leakage characteristics.
1.3 The test methods for two of the techniques also specify the auxiliary measurements needed to characterize the magnitude of the distribution system air leakage during normal operation.
1.4 A test method for the total recirculating air flow induced by the system blower is included so that the air distribution system leakage can be normalized as is often required for energy calculations.
1.5 The proper use of these test methods requires knowledge of the principles of air flow and pressure measurements.
1.6 Three of these test methods are intended to produce a measure of the air leakage from the air distribution system to outside. The other test method measures total air leakage including air leaks to inside conditioned space.
1.7 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.
1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Developme...
- Standard12 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Glass fiber reinforcing meshes are used to strengthen EIFS. The reinforcing meshes are embedded into base coats that contain portland cement, which potentially exposes the glass fibers in the reinforcing meshes to weakening by the action of alkali. The breaking force following alkali exposure as determined by this method, is a factor used to comparatively evaluate the alkali resistance of EIFS glass fiber reinforcing meshes in the laboratory.
5.2 This test method does not purport to simulate the conditions that may be encountered in service. The performance of an EIFS is a function of many factors, such as proper installation, rigidity of supporting construction and resistance of the EIFS to deterioration by other causes.
SCOPE
1.1 This test method covers procedures for determining the breaking force of glass fiber mesh following their conditioning in an alkali solution. The method is applicable to glass fiber mesh used in Class PB Exterior Insulation and Finish Systems (EIFS) with base coats that contain portland cement as an ingredient.
1.2 Breaking force is expressed both as force per unit width of mesh and as a percentage of the breaking force of the mesh that has not been exposed to alkali conditioning.
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
4.1 The purpose of this test method is to assess the installation adequacy and the overall effects of service-related deterioration (moisture, etc.) on the EIFS wall assembly as opposed to small localized areas of degradation. Resistance to pull testing as determined by this test is used as one of the factors in evaluating the EIFS assembly on a specific project. The values obtained by this test method are not purported to be representative of the actual wind load capacity or other structural properties of a specific EIFS clad wall installation, but may be helpful in assessing such load capacities.
4.2 Since this test is used for field evaluation of existing facilities, load results obtained from this test must be interpreted based on sound engineering practice, applicable building regulations, and codes having jurisdiction. It is the discretion of the test specifier to directly utilize the results derived by this test method, or else to utilize the test results with an appropriate factor of safety to obtain acceptable working loads for each project.
4.3 This method is intended for use on test specimens occurring or installed on existing buildings. The loss of outward wind load resistance of an EIFS wall assembly after exposure to moisture and other weather conditions may compromise the ability of the cladding or other wall components to perform adequately in place. This test method does not provide any means by which the test results may be generalized to the larger wall area. Such efforts should be based on experience and engineering judgement.
4.4 The manner in which the test load is applied may affect the load capacity obtained from using this test method. A discussion of various load application techniques and their effects is given in Appendix X1.
SCOPE
1.1 This test method covers a procedure to determine the resistance of a section of the exterior insulation and finish system (EIFS) to outward loads imposed on an existing exterior wall assembly that has been in place on the building for an unspecified period of time. It is destructive in nature within the localized areas tested and requires appropriate repair of the EIFS cladding and sheathing once the test procedure has been completed. This test procedure utilizes mechanical methods to obtain information, which may be helpful in evaluating the natural application of negative wind loads on the EIFS assembly. Some variability of results should be anticipated within the wall assembly tested due to differences in installation procedures, exposure, or abuse subsequent to application.
1.2 This test method is suitable for use on cladding assemblies that have been in place a short time (new construction), as well as for longer periods in order to evaluate detrimental effects on the EIFS lamina, insulation attachment, substrate integrity, and attachments after exposure to weather and other environmental conditions. It is not intended to evaluate the performance of structural framing. Test results on any particular building may be highly variable depending on specimen location and condition, and are subject to interpretation by the test specifier.
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.4 This standard may involve hazardous materials, operations, or equipment. This standard does not purport to address all of the safety concerns associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and to determine the applicability of regulatory limitations prior to use.
Note 1: Due to variations in exposure and construction assemblies, field specimens se...
- Standard8 pagesEnglish language
SIGNIFICANCE AND USE
4.1 The information contained in this guide is general in nature because of: the great number of commercially available firestop systems globally; the quantity and variety of internationally published firestop system’s listings; worldwide variations in building and fire code requirements; and the many conditions and applications associated with a firestop system’s use.
4.2 This guide provides general information and guidance that is primarily used by firestop contractors and firestop industry inspectors of a firestop system. However, this guide should also be used by others, such as architects, engineers, specifiers, etc. Some of the information referenced in this guide provides resources for additional information not contained in the manufacturer’s installations, the firestop system’s test report, and listing. Information contained in this guide also allows a single source for a general comparison of firestop materials used during the installation of firestop systems.
4.3 This guide discusses general procedures, such as substrate cleaning and priming, as well as installation of the components of a firestop system.
Note 2: The term “substrate” has a particular meaning in engineering. A substrate is defined as the “basic surface on which a material adheres, for example, paint or laminate.”21
4.4 This guide explains the general properties and functions of various penetrating items and firestop materials.
4.5 This guide presents general guidelines for the application of the various materials used in the installation of a firestop system for a specific application, and environmental conditions and effects that are known to potentially affect a firestop system’s installation.
4.6 This guide is intended to be read completely at least once, and each of the Sections 1 through 19 should be read in their entirety to avoid misunderstanding and misapplication.
4.7 This guide may22 also provide some value to users of IMO Safety of Life at Sea (SOLAS) and ot...
SCOPE
1.1 This guide is a compendium of information related to installing firestop systems in fire-separating elements. This guide is intended to be used to increase industry knowledge of national and international testing requirements, code prerequisites, and other supplemental tests that may be specified, which can affect the installation and performance of firestop systems.
1.2 This guide relates to the use of firestop systems tested, or evaluated, to Test Method E814 and other test methods addressing the same specific subject matter, such as CAN/ULC-S115; EN 1366-3; IMO Resolution MSC.307(88), FTP Code; IEEE 634; ISO 10295-1; UL 1479; etc.
1.3 This guide also addresses the use of firestop systems tested or evaluated to Test Methods E119 or other test methods that use a firestop system as a component of a typically larger test assembly, such as AS 1530.4; BS 476-21; BS 476;3 CAN/ULC-S101; ISO 834;4 NFPA 251; UL 263; etc.
1.4 This guide discusses the installation of firestop systems in membrane penetrations and through penetrations. The installation is typically performed by a firestop contractor (also known as a firestop installer or an installer). However, the quality of the installation is based on the information provided to the firestop contractor as well as the expertise and competence of the firestop contractor. A lack of information in the test report, listing, manufacturer’s instructions, or project documents can be the cause of a deficient installation.
1.5 The term “firestop system” refers to and includes both a membrane-penetration firestop system and through-penetration firestop system.
1.6 Information in this guide is applicable to firestop systems that accommodate single or multiple penetrating items.
1.7 This guide does not address the design aspects of locating and defining the dimensions of an opening; or the method to create the opening; or the inspection of the penetrating item prior to ...
- Guide22 pagesEnglish language
- Guide22 pagesEnglish language
ABSTRACT
This specification covers the minimum performance and acceptance criteria for an air barrier (AB) material or system for framed walls of low-rise buildings with the service life of the building wall in mind. The provisions contained in this specification are intended to allow the user to design the wall performance criteria and increase AB specifications to accommodate a particular climate location, function, or design of the intended building. This specification focuses mainly on ABs for opaque walls. Other areas of the exterior envelope, such as roofs, floors, and interfaces between these areas are not included in this specification. Also not addressed here are air leakages into the wall cavity, that is, windwashing. Additionally, the specifications in this standard are not intended to be utilized for energy load calculations and are not based on an expected level of energy consumption.
SCOPE
1.1 This specification covers minimum performances and specification criteria for an air barrier (AB) material or system for framed walls of low-rise buildings. The intended users are purchasers of the AB, specifiers of the AB and regulatory groups. The provisions contained in this specification are intended to allow the user to design the wall performance criteria and increase AB specifications to accommodate a particular climate location, function, or design of the intended building. Air barrier performance and specification minimums were selected with the service life of the building wall in mind.
1.2 This specification focuses on ABs for opaque walls. Other areas of the exterior envelope, such as roofs, floors, and interfaces between these areas are not included in this specification.
1.3 This specification does not address air leakage into the wall cavity, that is, windwashing. No standardized test has been developed that adequately identifies all of the influencing factors and measures the impact of this effect on the wall's thermal performance.
1.4 The specifications in this standard are not intended to be utilized for energy load calculations and are not based on an expected level of energy consumption.
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.6 The following safety hazards caveat pertains only to the test method portion, Annex A1, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification6 pagesEnglish language
- Technical specification6 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Effects of Air Change—Air change often accounts for a significant portion of the heating or air-conditioning load of a building. It also affects the moisture and contaminant balances in the building. Moisture-laden air passing through the building envelope can permit condensation and cause material degradation. An appropriate level of ventilation is required in all buildings; one should consult ASHRAE Standard 62 to determine the ventilation requirements of a building.
5.2 Prediction of Air Change—Air change depends on the size and distribution of air leakage sites, pressure differences induced by wind and temperature, mechanical system operation, and occupant behavior. Air change may be calculated from this information, however, many of the needed parameters are difficult to determine. Tracer gas testing permits direct measurement of air change.
5.3 Utility of Measurement—Measurements of air change provide useful information about ventilation and air leakage. Measurements in buildings with the ventilation system closed are used to determine whether natural air leakage rates are higher than specified. Measurements with the ventilation system in operation are used to determine whether the air change meets or exceeds requirements.
5.4 Known Conditions—Knowledge of the factors that affect air change makes measurement more meaningful. Relating building response to wind and temperature requires repetition of the test under varying meteorological conditions. Relating building response to the ventilation system or to occupant behavior requires controlled variation of these factors.
5.5 Applicability of Results—The values for air change obtained by the techniques used in this test method apply to the specific conditions prevailing at the time of the measurement. Air change values for the same building will differ if the prevailing wind and temperature conditions have changed, if the operation of the building is different, or if the envelope changes between m...
SCOPE
1.1 This test method covers techniques using tracer gas dilution for determining a single zone's air change with the outdoors, as induced by weather conditions and by mechanical ventilation. These techniques are: (1) concentration decay, (2) constant injection, and (3) constant concentration.
1.2 This test method is restricted to a single tracer gas.
1.3 The associated data analysis assumes that one can characterize the tracer gas concentration within the zone with a single value. The zone shall be a building, vehicle, test cell, or any conforming enclosure.
1.4 Use of this test method requires a knowledge of the principles of gas analysis and instrumentation. Correct use of the formulas presented here requires consistent use of units, especially those of time.
1.5 Determination of the contribution to air change by individual components of the zone enclosure is beyond the scope of this test method.
1.6 The results from this test method pertain only to those conditions of weather and zonal operation that prevailed during the measurement. The use of the results from this test to predict air change under other conditions is beyond the scope of this test method.
1.7 The text of this test method references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered requirements of this test method.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Reco...
- Standard18 pagesEnglish language
- Standard18 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Fenestration products, when exposed to differential temperatures (constant higher or lower temperatures on the exterior and room temperature on the interior), or temperature cycling (relatively constant room temperature on the interior and repeated cycling of higher and lower temperatures on the exterior), will have stresses induced on components that may cause failure or changes in overall system performance. Some of these changes may be temporary, with their effects on system performance lasting only during the cyclical temperature exposure. Other changes may be more permanent because of the failure of critical components or irreversible changes in those critical components that control overall system performance.
5.2 In this practice, a procedure is provided for evaluating the effects of exposure to temperature cycling at standardized conditions on fenestration products. It is useful for product evaluation and development. Interrelationships between window components can be studied under laboratory conditions simulating in-service temperature extremes.
5.3 Laboratory approximation of in-service temperature cycling and temperature extremes is a useful tool for the fenestration designer. These conditions help in evaluating designs and components for absolute and relative interactions on overall performance when these products are installed and functioning in residential and commercial buildings.
5.4 This practice is limited to temperature exposure and temperature cycling only. Temperature is only one of many environmental factors that affect field performance of fenestration products. Products made with different materials or construction methods may show specific sensitivity to different environmental factors, such as humidity, ultraviolet radiation, or airborne chemicals.
5.5 Because of the complexity and cost of a single apparatus capable of measuring window performance, providing temperature cycling, and providing infrared radiation exposure, mo...
SCOPE
1.1 This practice covers the testing of any fenestration products that are installed with the exterior surface exposed to weathering conditions. It is intended to measure the response of the fenestration product to temperature cycles with the temperature changes being induced by controlling the air temperature on the exterior (weather side) or by exposing the product to infrared radiation, or both. When tested using this practice, fenestration products are exposed to standard cycles of elevated and depressed ambient air and surface temperatures. Test methods are specified for evaluating changes in performance that may occur as a result of temperature cycling. With this practice, seasonal and diurnal temperature conditions are simulated in a controlled laboratory apparatus.
1.2 In this practice, two test methods, Test Method A and Test Method B, are described for exposing the exterior surface of fenestration products to the elevated portion of a standardized temperature cycle. The purpose for providing two test methods of exposure is to address two distinct needs of the fenestration industry.
1.2.1 Test Method A uses infrared radiation to increase the surface temperature of the fenestration product and uses a black panel temperature sensor placed in front of the specimen's exterior surface to sense the temperature. The surface temperature of the black panel temperature sensor is raised to a preset level above the exterior ambient air temperature. This provides a more realistic test for temperature exposure based on atmospheric solar radiation and its effect on the temperature increase of exterior building materials. This method should be used when the number of cycles can be large and the outcome is critical for field correlation. Test Method A is intended for comparative product evaluations.
1.2.2 Test Method B uses elevated temperature produced by convective hot air to achieve the exterior air temperature set-p...
- Standard7 pagesEnglish language
- Standard7 pagesEnglish language
SIGNIFICANCE AND USE
5.1 LCC analysis is an economic method for evaluating a project or project alternatives over a designated study period. The method entails computing the LCC for alternative building designs or system specifications having the same purpose and then comparing them to determine which has the lowest LCC over the study period.
5.2 The LCC method is particularly suitable for determining whether the higher initial cost of a building or building system is economically justified by reductions in future costs (for example, operating, maintenance, repair, or replacement costs) when compared with an alternative that has a lower initial cost but higher future costs. If a building design or system specification has both a lower initial cost and lower future costs relative to an alternative, an LCC analysis is not needed to show that the former is the economically preferable choice.
5.3 If an investment project is not essential to the building operation (for example, replacement of existing single-pane windows with new double-pane windows), the project must be compared against the “do nothing” alternative (that is, keeping the single pane windows) in order to determine if it is cost effective. Typically the “do nothing” alternative entails no initial investment cost but has higher future costs than the proposed project.
SCOPE
1.1 This practice establishes a procedure for evaluating the life-cycle cost (LCC) of a building or building system and comparing the LCCs of alternative building designs or systems that satisfy the same functional requirements.
1.2 The LCC method measures, in present-value or annual-value terms, the sum of all relevant costs associated with owning and operating a building or building system over a specified time period.
1.3 The basic premise of the LCC method is that to an investor or decision maker all costs arising from an investment decision are potentially important to that decision, including future as well as present costs. Applied to buildings or building systems, the LCC encompasses all relevant costs over a designated study period, including the costs of designing, purchasing/leasing, constructing/installing, operating, maintaining, repairing, replacing, and disposing of a particular building design or system.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard23 pagesEnglish language
ABSTRACT
This specification covers exterior windows, glazed curtain walls, doors and impact protective systems used in buildings located in geographic regions that are prone to hurricanes. The test specimens shall be Fenestration assemblies, and impact protective systems; which shall be tested using the large missile test, and small missile test. The air pressure cycling, missiles, and impact location are also detailed.
SCOPE
1.1 This specification covers exterior windows, glazed curtain walls, doors, and impact protective systems used in buildings located in geographic regions that are prone to hurricanes.
1.1.1 Exception—Exterior garage doors and rolling doors are governed by ANSI/DASMA 115 and are beyond the scope of this specification.
1.2 This specification provides the information required to conduct Test Method E1886.
1.3 Qualification under this specification provides a basis for judgment of the ability of applicable elements of the building envelope to remain unbreached during a hurricane; thereby minimizing the damaging effects of hurricanes on the building interior and reducing the magnitude of internal pressurization. While this standard was developed for hurricanes, it may be used for other types of similar windstorms capable of generating windborne debris.
1.4 This specification provides a uniform set of guidelines based upon currently available information and research.2 As new information and research becomes available it will be considered.
1.5 All values are stated in SI units and are to be regarded as standard. Values given in parentheses are for information only. Where certain values contained in reference documents cited and quoted herein are stated in inch-pound units, they must be converted by the user.
1.6 The following precautionary statement pertains only to the test method portion, Section 5, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification15 pagesEnglish language
- Technical specification15 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method is a standard procedure for determining water leakage through metal roof panel system sideseams, endlaps, and roof plane penetrations when the roof system is subjected to a specified static water pressure head.
Note 2: In applying the results of tests by this method, note that the performance of a roof or its components or both, is in part a function of proper installation and adjustment. In service, the performance will also depend on the integrity of the supporting construction, roof slope, and on the resistance of components to deterioration by various causes: corrosive atmosphere, aging, ice, vibration, thermal cycling, etc. It is difficult to simulate the identical complex wetting, aging, and other variable conditions that can be encountered in service, including wind-blown ponded water; the effects of temperature and age on sealant performance; differential pressure across the joints due to wind, snow, and ice accumulation; densification and migration; and abrasions within the joint components which may occur during thermal cycling and other weather events. Some joint conditions are more sensitive than others to these factors.
5.2 This test method will evaluate the resistance of roof panels, sideseams, endlaps, and roof plane penetrations to water submersion. It will not evaluate panel resistance to wind driven rain.
Note 3: See Test Method E1646 for a test which evaluates resistance to wind driven rain.
5.3 This test method is not a structural adequacy test.
5.4 This test method is applicable to single skin metal panels, the exterior skin of factory assembled composite panels, and the exterior skin of field assembled composite systems as long as means can be provided to distinguish leakage through the exterior panel sideseams/endlaps and perimeter leakage.
SCOPE
1.1 This laboratory test method covers the determination of the resistance to water penetration of exterior metal roof panel system sideseams, endlaps, and roof plane penetrations when a specified static water pressure head is applied to the outside face of the roof panel.
Note 1: This test method is intended to evaluate water-barrier (not water-shedding) roof system joints and details. These systems are also referred to as hydrostatic roof systems.
1.2 This test method is limited to specimens in which the sideseams and attachments are clearly visible and in which the source of leakage is readily observable.
1.3 This test method excludes performance at roof perimeter conditions.
1.4 This test method is suitable for evaluating leakage at roof plane penetrations such as fasteners, curbs, pipes, and expansion joints under a static water pressure head.
1.5 The proper use of this test method requires a knowledge of the principles of water pressure.
1.6 The text of this standard includes notes and footnotes excluding tables and figures, which provide explanatory material. These notes and footnotes shall not be considered as requirements of the standard.
1.7 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 7.
1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
4.1 This test method is intended to provide data from which applicable design data can be derived for a given anchorage.
SCOPE
1.1 This test method covers procedures to be followed in testing the performance of the anchorage of all types of new and existing permanent metal railing systems (guard, stair, and ramp-rail systems), and rails (hand, grab, and transfer rails) installed in and for agricultural, assembly, commercial, educational, industrial, institutional, recreational, and residential buildings.
1.2 This test method is applicable to railing systems and rails having major structural components made of metal and secondary components made of metal or other materials such as wood, plastics, and glass.
1.3 The test method described can be used to determine whether the anchorage of permanent metal railing systems and rails complies with anticipated performance requirements.
1.4 Specifically, this test method covers procedures for determining the static tension, shear, and moment resistance of anchorages for permanent metal railing systems, and rails in structural elements made of concrete, masonry, wood, and metal as well as related products.
1.5 No consideration is given in this test method to any possible deterioration of anchorage systems, resulting from adverse environmental conditions. The performance of special tests covering this aspect may be desirable.
1.6 Should computations make it possible to provide the needed information, testing may be employed for purposes of verification.
1.7 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 6.
1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard9 pagesEnglish language
- Standard9 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The fan pressurization procedure provides a relatively fast evaluation of the airtightness of building envelopes. In order for the accuracy of the test results to be known, the airflow rate measurement technique of the fan pressurization system must be calibrated.
5.2 This test method is applicable to fan pressurization systems that are installed in an opening in the building envelope, as opposed to pressurization techniques involving the mechanical ventilation system of the building.
5.3 The technique of pressurization testing of buildings puts specific requirements on the calibration of fan pressurization systems. The calibration must cover the range of fan pressure differences (approximately 12.5 Pa to 75 Pa) that is induced during pressurization tests. The calibration must also cover a range in fan airflow rates corresponding to the range in building size and airtightness that the fan pressurization system will encounter in the field.
5.4 The fan pressurization system must be calibrated in both directions of airflow used to pressurize and depressurize a building if the system airflow direction is reversible. These two calibrations can be conducted using the various setups described in this test method; however some of the setups can be combined such that a single calibration facility can be used to calibrate the fan in both directions. Such a single setup may involve moving the fan pressurization system from one end of the chamber to the other, reversing the orientation of the system at the same end of the chamber, or it may not require moving the system at all.
5.5 The calibration technique is applicable to the two basic types of fan pressurization systems in use, r/min doors and signal doors.
5.6 For fan pressurization systems that operate in multiple ranges of airflow rate, the system must be calibrated in each range.
5.7 The calibration technique is intended to provide a complete calibration of a fan pressurization system. After calibra...
SCOPE
1.1 This test method covers the airflow measurement calibration techniques for fan pressurization systems used for measuring air leakage rates through building envelopes.
1.2 This test method is applicable to systems used for air leakage measurement as described in Test Methods E779, E1827, E3158, and ANSI/RESNET/ICC 380.
1.3 This test method involves the installation of the fan pressurization system in a calibration chamber. Use of the fan pressurization system in an actual building may introduce additional errors in the airflow measurement due to operator influence, interference of internal partitions and furnishings, weather effects, and other factors.
1.4 The proper use of this test method requires a knowledge of the principles of airflow and pressure measurement.
1.5 This standard includes two basic procedures, a preferred procedure, based on ASHRAE 51/AMCA 210, and an optional procedure based on a nonstandard airflow measurement technique, commonly used by manufacturers of fan pressurization devices, but which has not been compared with standard airflow measurement techniques.
1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard9 pagesEnglish language
- Standard9 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Certain properties, namely thickness and density, of SFRM are basic. It is the intent of these test methods to provide procedures to determine these properties.
SCOPE
1.1 These test methods cover procedures for determining thickness and density of sprayed fire-resistive material (SFRM) used in structural assemblies. These include sprayed fiber and cementitious types. The test methods are applicable to both laboratory and field procedures, as indicated in Section 7.
1.2 These test methods require the application of SFRM in accordance with the manufacturers’ published instructions. The apparatus, materials, and procedure used to apply the SFRM for laboratory tests shall be the same as is used for the construction of either of the test assemblies described in Test Methods E119 and E84.
1.3 There is no intent in these test methods to establish levels of performance.
1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard6 pagesEnglish language
SIGNIFICANCE AND USE
4.1 The intent of this test method is to determine a property of SFRM that may be used to provide an indication of its in-place serviceability. Satisfactory performance of SFRM applied to structural members and assemblies depends upon its ability to withstand the various influences that may occur during construction and during the life of the structure, as well as upon its satisfactory performance under fire conditions.
4.2 The test method measures the behavior of SFRM when the floor construction to which it is applied is subjected to shock loading and evaluates adhesion and resistance to spalling, cracking, and delamination. It is an indication of the ability of SFRM to remain in place and resist removal during anticipated service conditions.
SCOPE
1.1 This test method covers a procedure for determining the effect of impact loading on the bonding of sprayed fire-resistive material (SFRM) applied to the underside of steel floor deck. These materials include sprayed fibrous and cementitious materials applied directly in contact with the structural members. The test method is applicable only to laboratory procedures.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard2 pagesEnglish language
SIGNIFICANCE AND USE
4.1 The intent of this test method is to determine properties of direct-applied SFRM that may be used to provide an indication of serviceability. Satisfactory performance of fire-resistive material applied to structural members and assemblies depends upon its ability while in place to withstand the various influences that may occur during the life of the structure, as well as upon its satisfactory performance under fire tests.
4.2 This test method measures the compressive strength of SFRM and is a measure of the resistance to deformation under a compressive load. It is an indication of the ability of SFRM to remain in place and resist removal during anticipated service conditions.
SCOPE
1.1 This test method covers a procedure for measuring the compressive strength of sprayed fire-resistive material (SFRM) applied to a rigid substrate. These fire-resistive materials include sprayed fibrous and cementitious materials applied directly in contact with these structural members. The test method is applicable to laboratory procedure.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
5.1 It is the intent of this test method to determine relative corrosive properties of direct applied SFRM that provides an indication of serviceability. Satisfactory performance of SFRM applied to structural members and assemblies depends upon its ability to withstand the various influences that occur during the life of the structure, as well as upon its satisfactory performance under fire conditions.
5.2 This test method evaluates the relative corrosion of steel induced by SFRM and determines whether the presence of SFRM increases, decreases, or has no effect on the corrosion characteristics of steel.
SCOPE
1.1 This test method covers a procedure for measuring the corrosion to steel induced by sprayed fire-resistive material.
1.2 These SFRMs include sprayed fibrous and cementitious materials applied directly in contact with the structural members.
1.3 This test method is applicable only to laboratory procedures.
1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This practice is intended for use by the material specifier, general contractor, applicator, or any individual group requiring information regarding the application of SFRM.
5.2 This practice is not intended to replace the manufacturers' application instructions.
SCOPE
1.1 This practice covers guidelines for application of sprayed fiber and cementitious fire-resistive materials.
1.2 This practice is general in nature. It is not intended to cover all requirements for application.
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 10 and 14.1.2.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
5.1 It is the intent of this test method to determine properties of SFRM that may be used to provide an indication of serviceability. Satisfactory performance of SFRM applied to structural members and assemblies depends upon its ability to withstand the various influences that may occur during construction and during the life of the structure, as well as upon its performance under fire conditions.
5.2 Air erosion tests on SFRMs are conducted to evaluate the behavior of the SFRM when subjected to plenum air streams during normal service conditions. Such tests evaluate the resistance to dusting, flaking, spalling, and delamination of the SFRM.
SCOPE
1.1 This test method covers a procedure for determining the effect of an air stream upon sprayed fire-resistive materials (SFRMs). These SFRMs include sprayed fibrous and cementitious materials. The test method is applicable only to laboratory procedures.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard3 pagesEnglish language
- Standard3 pagesEnglish language
ABSTRACT
This specification covers flexible, preformed sheet membrane materials to be used as vapor retarders in contact with soil or granular fill under concrete slabs. The specified tests are conducted on new materials and materials that have been conditioned or exposed to simulate potential service conditions. The membranes are classified into 3 classes. The materials shall be subject to tests for water vapor permeance, tensile strength, and puncture resistance. Under special conditions, the material shall also conform to the required flame spread, permeance after soil poison petroleum vehicle exposure, and permeance after exposure to ultraviolet light.
SCOPE
1.1 This specification covers flexible, preformed sheet membrane materials to be used as vapor retarders in contact with soil or granular fill under concrete slabs.
1.1.1 This specification does not cover bituminous vapor retarders. See Specification E1993/E1993M for information on bituminous vapor retarders.
1.2 The specified tests are conducted on new materials and materials that have been conditioned or exposed to simulate potential service conditions.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification3 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Measuring cost risk enables owners of buildings and other constructed projects, architects, engineers, and contractors to measure and evaluate the cost risk exposures of their construction projects.3 Specifically, cost risk analysis (CRA) helps answer the following questions:
5.1.1 What are the probabilities for the construction contract to be bid above or below the estimated value?
5.1.2 How low or high can the total project cost be?
5.1.3 What is the appropriate amount of contingency to use?
5.1.4 What cost elements have the greatest impact on the project’s cost risk exposure?
5.2 CRA can be applied to a project's contract cost, construction cost (contract cost plus construction change orders), and project cost (construction cost plus owner's cost), depending on the users’ perspectives and needs. This practice shall refer to these different terms generally as “project cost.”
SCOPE
1.1 This practice covers a procedure for measuring cost risk for buildings and building systems and other constructed projects, using the Monte Carlo simulation technique as described in Guide E1369.
1.2 A computer program is required for the Monte Carlo simulation. This can be one of the commercially available software programs for cost risk analysis, or one constructed by the user.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard9 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The AHP method allows you to generate a single measure of desirability for project/product/process alternatives with respect to multiple attributes (qualitative and quantitative). By contrast, life-cycle cost (Practice E917), net savings (Practice E1074), savings-to-investment ratio (Practice E964), internal rate-of-return (Practice E1057), and payback (Practice E1121) methods all require you to put a monetary value on benefits and costs in order to include them in a measure of project/product/process worth.
5.2 Use AHP to evaluate a finite and generally small set of discrete and predetermined options or alternatives. Specific AHP applications are ranking and choosing among alternatives. For example, rank alternative building locations with AHP to see how they measure up to one another, or use AHP to choose among building materials to see which is best for your application.
5.3 Use AHP if no single alternative exhibits the most preferred available value or performance for all attributes. This is often the result of an underlying trade-off relationship among attributes. An example is the trade-off between low desired energy costs and large glass window areas (which may raise heating and cooling costs while lowering lighting costs).
5.4 Use AHP to evaluate alternatives whose attributes are not all measurable in the same units. Also use AHP when performance relative to some or all of the attributes is impractical, impossible, or too costly to measure. For example, while life-cycle costs are directly measured in monetary units, the number and size of offices are measured in other units, and the public image of a building may not be practically measurable in any unit. To help you choose among candidate buildings with these diverse attributes, use AHP to evaluate your alternatives.
5.5 The AHP method is well-suited for application to a variety of sustainability-related topics. Guide E2432 states when applying the concept of sustainability, it is necessary ...
SCOPE
1.1 This practice presents a procedure for calculating and interpreting AHP scores of a project’s/product’s/process’ total overall desirability when making capital investment decisions.3 Projects include design, construction, operation, and disposal of commercial and residential buildings and other engineered structures.4 Products include materials, components, systems, and equipment.5 Processes include procurement, materials management, work flow, fabrication and assembly, quality control, and services.
1.2 In addition to monetary benefits and costs, the procedure allows for the consideration of characteristics or attributes which decision makers regard as important, but which are not readily expressed in monetary terms. Examples of such attributes that pertain to the selection among project/product/process alternatives are: a construction projects’s building alternatives whose nonmonetary attributes are location/accessibility, site security, maintainability, quality of the sound and visual environment, and image to the public and occupants; building products based on their economic and environmental performance; and sustainability-related issues for key construction processes that address environmental needs, while considering project safety, cost, and schedule.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard20 pagesEnglish language
SIGNIFICANCE AND USE
5.1 These test methods are intended to establish a measure of resistance for sliding door assemblies subjected to attacks (other than impacting glazing materials) by unskilled or opportunistic burglars. Resistance to higher levels of force generated by skilled burglary attack requires methods, such as alarms, communication, or apprehension systems, or special security glazing materials more sophisticated than those evaluated by these test methods. Technicians performing the test should understand the intent of this test method and should be trained on the execution and pass/fail criteria.
5.2 Entry through a sliding door assembly can be accomplished by impacting or removing glazing materials. This method does not evaluate glazing materials for breakage or de-glazing. Other standards must be used to evaluate forced entry by impacting or removing glazing.
5.3 Acceptance criteria for performance levels are a matter for authorities having specific jurisdiction to establish. Suggested guidelines are found in Annex A1.
SCOPE
1.1 These test methods determine the ability of sliding door assemblies to restrain, delay, or frustrate forced entry.
1.2 For purposes of these test methods, sliding door assemblies are defined as described in 1.2.1 – 1.2.4 and as shown in Fig. 1. Sliding door assemblies with a combination of operable panels and fixed panels (lites) shall be classified and tested separately for each type.
FIG. 1 Typical Horizontal Sliding Door Assembly Types (viewed from the exterior)
1.2.1 Type A—A sliding door assembly which incorporates one or more sliding panels that lock to the jamb.
1.2.2 Type B—A sliding door assembly which incorporates one or more sliding panels that lock to an intermediate jamb.
1.2.3 Type C—A sliding door assembly which incorporates one or more sliding panels that abut and lock to other panels.
1.2.4 Type D—A sliding door assembly which incorporates one or more fixed or stationary panels that are designed not to open.
Note 1: See Fig. 1 for graphic depiction of sliding door assembly types.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard16 pagesEnglish language
SIGNIFICANCE AND USE
4.1 When preparing construction, project, and program cost estimates, it is often necessary to make monetary provision for change or risk, or both, or other exigencies where information is incomplete.
4.2 Such allowance, contingency or reserve sums are employed by many persons engaged in the planning, delivery, and financing of construction work.
4.3 These users include owners, developers, facilities programmers, cost planners, estimators, schedules, architects and engineers, specification writers, operating and maintenance staff, manufacturers, educators, financial managers, and comptrollers.
4.4 Usage:
4.4.1 These sums are especially appropriate when performing the following activities:
Cost budgeting;
Conceptual, design, and construction cost estimating;
Preparing complete forecast cost for economic evaluation,
investment analysis, and approval; and
Controlling cost during planning, design, and construction.
4.4.2 In any of these activities a needed requirement, or component, of the planned construction can be known while the defined solution, design or specification, for providing this may not. The usual, and appropriate, response in these situations, is the inclusion of a monetary sum, within an estimate, to provide for this (these) requirement(s).
4.4.3 Such sums may be general or specific in scope, may be planned to be spent or may only be included as possible mitigation for unplanned events and requirements.
4.4.4 To distinguish between these sums, and in recognition of their differing purpose, they are described, and classified here, using the terms allowance, contingency, or reserve.
Note 1: Section 5 includes a generic statement of purpose for each of the three terms and provides a sub-classification that distinguishes between sums included for specific purposes and for non-specific, that is, general purposes. In cost budgeting, conceptual and design estimating especially, an estimator may intuitively recognize...
SCOPE
1.1 This classification establishes a classification for allowance, contingency, and reserve sums used in construction, project, and program estimating.
1.2 This classification applies to all construction work.
1.3 This classification is not based on permanent physical elements of construction (as defined and classified in Classification E1557). Rather, the classification items are cost components common to construction, project, and program estimates.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard9 pagesEnglish language
ABSTRACT
This specification covers corrosion-inhibiting adhesive primers for use on aluminum alloys that are to be adhesively bonded in the fabrication of honeycomb sandwich panels for tactical shelters. When applied to a properly cleaned surface of aluminum alloy, the primer imparts corrosion resistance and forms a surface suitable for structural bonding and coating with shelter paint finishes. The primer shall be a pigmented liquid composed of a modified epoxy resin system, compounded so that it can be spray-applied to produce a continuous coating without the addition of any solvent. Uncured primers shall be tested for solids content, inhibitor content, storage stability, shelf life, color, sprayability, and curing properties. Cured films, on the other hand, shall be tested on adhesion to metal, impact resistance, pencil hardness, water resistance, environmental resistance, corrosion resistance, humidity aging, heat resistance, and low-temperature shock. Finally, bonded specimens shall be tested and conform to normal-, low-, and high-temperature lap shears, humidity-exposure lap shear, salt-spray exposure lap shear, and normal- and low-temperature floating roller peel strengths.
SCOPE
1.1 This specification covers sprayable, pigmented liquid primers for use on aluminum alloys that are to be adhesively bonded in the fabrication of honeycomb sandwich panels for tactical shelters. When applied to a properly cleaned surface of aluminum alloy, the primer imparts corrosion resistance and forms a surface suitable for structural bonding using adhesives complying with Specification E865 and for coating with shelter paint finishes.
1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification5 pagesEnglish language
- Technical specification5 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This practice increases the level of communication, provides an organized approach to cost control during the design of a project, and also provides a means of identifying extraordinary cost items and changes in assumptions between estimates.
5.2 The users of this practice include owners, developers, contractors, cost professionals, estimators, architects, engineers, specification writers, quantity surveyors, and anyone charged with the responsibility of successfully managing the design of a building and its related site work within a specified project budget.
5.3 Use this reporting format during the following:
5.3.1 Contracting for design cost analysis services,
5.3.2 Comparing the current design costs to a previous estimate, and
5.3.3 Responding to each design phase.
5.4 This practice provides a tool for analyzing design options and examining strategies to maintain the project budget.
SCOPE
1.1 This practice covers an arranged method for providing cost analysis during the design phase of a building project.
1.2 The use of this practice increases the level of communication between the design professional, owner, and the cost professional providing the cost consulting services.
1.3 The practice establishes a structured method to support design decisions.
1.4 The practice provides design and cost professionals with a framework for historically tabulating information to be used on relevant future projects.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
5.1 These test methods are intended to establish a measure of resistance for window assemblies subjected to attacks (other than impacting glazing materials) by unskilled or opportunistic burglars. Resistance to higher levels of force generated by skilled burglary attack requires methods such as alarms, communication, or apprehension systems, or special security glazing materials more sophisticated than those evaluated by these test methods. Technicians performing the test should understand the intent of this test method and should be trained on the execution and pass/fail criteria.
5.2 Entry through a window assembly can be accomplished by impacting the glazing materials. This method does not evaluate glazing materials for breakage. Other standards must be used to evaluate forced entry by impacting the glazing.
5.3 Acceptance criteria for performance levels are a matter for authorities having specific jurisdiction to establish. Suggested guidelines are found in Annex A1.
SCOPE
1.1 These test methods cover the ability of window assemblies of various types to restrain, delay, or frustrate forced entry.
1.2 For purposes of these test methods, window assemblies are defined as described in 1.2.1 – 1.2.5 and as shown in Fig. 1. Window assemblies with a combination of operable sash and fixed panes (lites) shall be classified and tested separately for each type.
FIG. 1 Typical Window Types (viewed from the exterior)
1.2.1 Type A—A window assembly which incorporates one or more sash that open by sliding, either vertically or horizontally within the plane of the wall.
1.2.2 Type B—A window assembly which incorporates one or more sash that are hinged at or near two corners of the sash and that open toward the exterior (outswinging) or toward the interior (inswinging).
1.2.3 Type C—A window assembly which incorporates one or more sash that are pivoted so that part of the sash opens toward the interior and part of it opens toward the exterior.
1.2.4 Type D—A window assembly which incorporates one or more fixed panes (lites) or stationary sash that are designed not to open.
1.2.5 Type E—A window assembly which incorporates a series of overlapping horizontal louvers that are pivoted simultaneously by a common actuator so that the bottom edge of each louver swings outward and the top edge swings inward during operation.
Note 1: See Fig. 1 for graphic depiction of window assembly types.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory requirements prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard14 pagesEnglish language
SIGNIFICANCE AND USE
4.1 Use this practice to organize information that describes new or existing buildings of any size. The concepts presented here can also be applied to other categories of construction where a standard corresponding to UNIFORMAT II does not yet exist.
4.2 The hierarchical structure of UNIFORMAT II enables the user to focus on building elements in functionally consistent groups. It can be applied by an administrator initiating a data system as a facility standard, as well as a consultant reporting on building conditions.
4.2.1 A consistent method of arrangement for subject matter expedites the preparation and use of source documents, and simplifies the process of comparing information from several sources.
4.3 This practice is suitable for arranging the content of individual reports, managing physical files, as well as automated data applications. Personal computers operating commercially available software are able to meet the functional requirements of this practice.
4.4 This practice provides a consistent and comprehensive outline suitable to track the evolution of specific building conditions in one or many buildings. It can be applied to historical building data as well as new information.
4.5 Administration of this practice will reveal categories of building data that have been overlooked in prior data gathering efforts that did not rely on a systems approach. The comprehensive hierarchy of Systems and Elements, readily displays the amount and depth of information distributed among the categories and levels. The pattern of available information highlights voids among the categories. It is also possible to quickly focus on the quality and sufficiency of cataloged data to determine whether an appropriate level of detail exists to address the needs of decision makers.
SCOPE
1.1 This practice covers the organization of building information to support informed decision making. The kinds of data considered in this practice include text, numeric, and graphic data. The system of organization is applicable to a wide range of data collection and organization tasks from routine in-depth analysis of a single building, to situations where many buildings must be evaluated and prioritized in a short time frame.
1.2 The organizational structure is based on Classification for Building Elements and Related Sitework—UNIFORMAT II (Classification E1557), a system which groups building elements according to the way buildings are constructed and function.
1.3 The use of UNIFORMAT II provides a set of recognized summary levels that are relevant throughout the industries that design, construct, and manage buildings.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard6 pagesEnglish language
ABSTRACT
This specification covers pigmented, sprayable, low volatile organic compound (VOC) corrosion-inhibiting adhesive primers for use on aluminum alloys that are to be adhesively bonded in the fabrication of panels for tactical or relocatable shelters. When applied to a properly prepared surface of aluminum alloy, the primer imparts corrosion resistance and forms a surface suitable for structural bonding and for coating with shelter paint finishes. The physical properties of uncured liquid polymer, cured film on primed surfaces, and bonded specimens shall conform to the prescribed requirements.
SCOPE
1.1 This specification covers pigmented, sprayable, low volatile organic compound (VOC) corrosion-inhibiting adhesive primers for use on aluminum alloys that are to be adhesively bonded in the fabrication of panels for tactical shelters. When applied to a properly prepared surface of aluminum alloy, the primer imparts corrosion resistance and forms a surface suitable for structural bonding and for coating with shelter paint finishes.
1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification5 pagesEnglish language
- Technical specification5 pagesEnglish language
SIGNIFICANCE AND USE
4.1 This standard builds on the concepts and organizational framework established in Classification E1557. This classification describes transportation surface elements that are major components of most vehicular transportation surfaces. The elemental classification is the common thread linking activities and participants in a transportation surface project from initial planning through operations, maintenance, and disposal.
Note 1: As this classification refers solely to permanent, physical parts of any construction, two additional classifications, Classifications E2083 and E2168, need to be included when calculating construction cost. These standards provide for the inclusion of construction enabling, temporary, and risk mitigation cost figures. Procedures for reporting all these figures are described in Practices E1804 and E2514 and Classification E2516. While these three latter standards were primarily written for building construction, they are nonetheless appropriate and readily applied to other forms of construction as well.
4.2 The users of transportation surface UNIFORMAT II include:
4.2.1 Financial and Investment-Typically owners, developers, bankers, lenders, accountants, and financial managers.
4.2.2 Implementation-Primarily project managers; facilities programmers; designers, including engineers; and project controls specialists, including cost planners, estimators, schedulers, specification writers, and risk analysts.
4.2.3 Facilities Management-Comprising property portfolio managers, operating staff, and maintenance staff.
4.2.4 Others-Public officials, manufacturers, educators, students, and other project stakeholders.
4.3 Apply This Classification When Undertaking the Following Work on Transportation Surface Projects:5
4.3.1 Financing and Investing:
4.3.1.1 Structuring costs on an elemental basis for economic evaluations (Guide E1185 and Practices E917, E964, E1057, E1074, E1121, and E1804) early in the design process help...
SCOPE
1.1 This standard establishes a classification of transportation surface elements within the UNIFORMAT II family of elemental classifications. It covers the full breadth of vehicular transportation surfaces, from rural roads to multi-lane interstate highways.
1.2 UNIFORMAT II classifications have an elemental format similar to the original UNIFORMAT2 building elemental classification. However, the title UNIFORMAT II differs from the original in that it now takes into consideration a wide range of constructed entities that collectively form the built environment.
1.3 Elements, as defined here and in Classifications E1557 and E2103/E2103M, are major physical components that are common within constructed entities. Elements perform their given function(s), regardless of the design specification, construction method, or materials used.
1.4 This elemental classification serves as a consistent reference for analysis, evaluation, and monitoring during the feasibility, planning, and design stages when constructing transportation surfaces.
1.5 Using UNIFORMAT II elemental classifications ensures a consistency in the economic evaluation of construction projects over time and from project to project.
1.6 UNIFORMAT II classifications also enhance reporting at all stages of a constructed entity’s life cycle-from feasibility and planning through the preparation of working documents, construction, maintenance, rehabilitation, and disposal.
1.7 This classification is unsuitable for process applications or for preparing trade estimates.
1.8 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.9 This standard does not purport to address al...
- Standard12 pagesEnglish language
SIGNIFICANCE AND USE
4.1 This practice recognizes that the effective performance of installed fenestration products is dependent in part upon following proper installation procedures and appropriate workmanship.
4.2 This practice recognizes that the coordination of trades and proper sequencing are essential for effective fenestration installation. The general contractor shall be responsible for the necessary coordination of trades and proper construction sequencing of the installed fenestration product.
4.3 Improper installation of units contributes to excessive air, water and sound leakage, and condensation. It may promote the deterioration of wall constructions, insulation, fenestration products, and their respective finishes.
4.4 This practice presumes a working knowledge of applicable federal, state, and local codes and regulations, specifically, but not limited to required means of egress, requirements for safety glazing materials, and structural requirements of applicable codes.
4.5 This practice presumes a working knowledge of the tools, equipment, and methods necessary for the installation of specified fenestration products. It further assumes familiarity with flashing and sealing, glazing procedures, finishes where applicable, and an understanding of the fundamentals of construction that affect the installation of these units.
4.6 This practice presumes that the products that have been furnished for the installation and their locations within the structure comply with all the applicable building codes and regulations.
SCOPE
1.1 This practice covers the installation of fenestration products in new and existing construction. For the purpose of this practice, fenestration products shall be limited to windows, sliding patio-type doors, swinging patio type doors, and skylights, as used primarily in residential and light commercial buildings.
1.2 This practice assumes that the installer possesses basic woodworking skills and an understanding of wall and roof construction, sheet metal work, and joint sealant practices.
1.3 This practice attempts to instruct and familiarize the installer with the concepts of both Barrier Systems and Membrane/Drainage Systems, in order to ensure the continuity of the building envelope. This practice attempts to educate the installer, builder, architect, and other users in the identification and understanding of the water shedding system of the building envelope.
1.4 This practice covers the installation process from pre-installation procedures through post-installation procedures, for single units or factory-mulled multiple units in a single opening. It does not cover the fabrication or assembly of multiple units, whether such fabrication takes place in a factory or at the intended installation site. The installer should check with the manufacturer of factory-assembled units for instructions for anchoring. When using field-mulled units, follow manufacturer's recommendations and make certain that they meet applicable codes. This practice does not cover the selection of appropriate fenestration products for a given application, nor the selection of other products or systems for use in the installation.
1.5 This practice provides minimum requirements that will help to accomplish the installation of fenestration products in an effective manner. Actual conditions in buildings vary greatly and, in some cases, substantial additional precautions may be required. In the event that the manufacturer's installation instructions provided with the product conflict with requirements of this practice, the manufacturer's instructions shall prevail. This practice is not intended to limit or exclude other new procedures that may refine or further improve the effectiveness of fenestration installation.
1.5.1 This practice is intended to be used for background information in order to develop training manuals and training programs. Further, this practice attempts to cons...
- Standard113 pagesEnglish language
- Standard113 pagesEnglish language
SIGNIFICANCE AND USE
4.1 Exterior wall systems require time to design, fabricate, construct and test. Mockups are generally a full-size representative portion of the proposed exterior wall system built to study proposed construction details, test for performance, and in some cases judge appearance of the exterior wall system. The project schedule shall allow time to design, construct, and test the pre-construction mockup and to implement any design changes, fabrication changes, or modifications of planned construction procedures, before construction of the exterior wall system commences.
4.2 Performance testing of pre-construction mockups verifies compliance with specified standards and design criteria. Performance tests in separate ASTM or other industry standards, are intended to represent the effects of environmental conditions, such as wind, rain, and temperature extremes. The tests provide a measure of the performance of the proposed exterior wall system under specific and controlled conditions. The specified design and specification of the pre-construction mockup must be appropriate for the performance test requirements. Separate tests may be required for individual mockup materials or components.
4.3 Pre-construction mockup specimens require input from Specifier, Builder, and Test Agency. Coordination of their efforts facilitates this process. Documentation should convey the results of preconstruction mockups from one party to others at appropriate stages in the process.
4.4 The referenced standards provided in this practice identify the historical standards typically utilized in pre-construction performance testing. This practice allows for the development and use of other project specific test procedures for various components that encompass exterior wall systems.
SCOPE
1.1 This standard practice covers procedures and documentation to assist in the specification and evaluation of pre-construction laboratory mockups of exterior wall systems.
1.2 This standard practice addresses design and construction of the mockup, observation during mockup construction and testing, evaluation of the mockup test results, and documentation of the mockup and testing process. Coordination is required between the parties involved in the design, construction, and testing of the mockup to facilitate this process. Documentation should convey the results of pre-construction mockups from one party to others at appropriate stages in the process.
1.3 This standard practice recommends the selection and order of individual tests performed on the mockup in the absence of a specific test order.
1.4 This standard practice recommends a protocol for exchange of information between participants in the pre-construction mockup process.
1.5 Responsibility for specific activities is recommended by this practice. This practice is intended to provide a default structure in the absence of the assignment of specific responsibilities by the specifying authority.
1.6 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
4.1 The intent of this test method is to determine a property of SFRM that may be used to provide an indication of its in-place serviceability. Satisfactory performance of SFRM applied to structural members and assemblies depends upon its ability to withstand the various influences that may occur during construction and during the life of the structure, as well as upon its satisfactory performance under fire conditions.
4.2 For cohesion/adhesion testing of installed asbestos-containing sprayed fire-resistive materials, refer to Practice E1494.
SCOPE
1.1 This test method covers a procedure for measuring the cohesion/adhesion or bond strength (tensile) perpendicular to the surface of sprayed fire-resistive material (SFRM) applied to rigid backing. These fire-resistive materials include sprayed fibrous and cementitious materials. The test method is applicable to both laboratory and field procedures as indicated in Section 7.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
4.1 The intent of this test method is to determine properties of direct-applied SFRM that may be used to provide an indication of serviceability. Satisfactory performance of fire-resistive material applied to structural members and assemblies depends upon its ability while in place to withstand the various influences that may occur during the life of the structure, as well as upon its satisfactory performance under fire tests.
4.2 This test method measures the behavior of SFRM when subjected to deflection and evaluates such phenomena as spalling and delamination under bending stress. It is an indication of the ability of SFRM to remain in place and resist removal during anticipated service conditions.
SCOPE
1.1 This test method covers a procedure for determining the effect of deflection on sprayed fire-resistive material (SFRM) applied to steel deck. These materials include sprayed fibrous and cementitious materials applied directly in contact with the structural members. The test method is applicable only to laboratory procedures.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard2 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method is a standard procedure for determining the resistance to water penetration under uniform static air pressure differences. The air-pressure differences acting across a building envelope vary greatly. These factors should be fully considered prior to specifying the test pressure difference to be used.
Note 1: In applying the results of tests by this test method, note that the performance of a wall or its components, or both, may be a function of proper installation and adjustment. In service, the performance will also depend on the rigidity of supporting construction and on the resistance of components to deterioration by various causes, vibration, thermal expansion and contraction, etc. It is difficult to simulate the identical complex wetting conditions that can be encountered in service, with large wind-blown water drops, increasing water drop impact pressures with increasing wind velocity, and lateral or upward moving air and water. Some designs are more sensitive than others to this upward moving water.
Note 2: This test method does not identify unobservable liquid water which may penetrate into the test specimen.
SCOPE
1.1 This test method covers the determination of the resistance of exterior windows, curtain walls, skylights, and doors to water penetration when water is applied to the outdoor face and exposed edges simultaneously with a uniform static air pressure at the outdoor face higher than the pressure at the indoor face.
1.2 This test method is applicable to any curtain-wall area or to windows, skylights, or doors alone.
1.3 This test method addresses water penetration through a manufactured assembly. Water that penetrates the assembly, but does not result in a failure as defined herein, may have adverse effects on the performance of contained materials such as sealants and insulating or laminated glass. This test method does not address these issues.
1.4 The proper use of this test method requires a knowledge of the principles of pressure measurement.
1.5 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see 7.1.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method is a standard procedure for determining the resistance to water penetration under uniform or cyclic static air pressure differences of installed exterior windows, skylights, curtain walls, and doors. The air-pressure differences acting across a building envelope vary greatly. These factors should be considered fully prior to specifying the test pressure difference to be used.
Note 1: In applying the results of tests by this test method, note that the performance of a wall or its components, or both, may be a function of proper installation and adjustment. In service, the performance will also depend on the rigidity of supporting construction and on the resistance of components to deterioration by various causes, vibration, thermal expansion and contraction, and so forth. It is difficult to simulate the identical complex wetting conditions that can be encountered in service, with large wind-blown water drops, increasing water drop impact pressures with increasing wind velocity, and lateral or upward moving air and water. Some designs are more sensitive than others to this upward moving water.
Note 2: This test method does not identify unobservable liquid water which may penetrate into the test specimen.
5.2 Laboratory tests are designed to give an indication of the performance of an assembly. Field performance may vary from laboratory performance since the supporting structure for the test specimen, methods of mounting, and sealing in the laboratory can only simulate the actual conditions that will exist in the building. Shipping, handling, installation, acts of subsequent trades, aging, and other environmental conditions all may have an adverse effect upon the performance of the installed product. This field test procedure provides a means for determining the performance of a product once installed in the building.
5.3 The field test may be made at the time the window, skylight, curtain-wall, or door assemblies are initially installed ...
SCOPE
1.1 This test method covers the determination of the resistance of installed exterior windows, curtain walls, skylights, and doors to water penetration when water is applied to the outdoor face and exposed edges simultaneously with a static air pressure at the outdoor face higher than the pressure at the indoor face.
1.2 This test method is applicable to any curtain-wall area or to windows, skylights, or doors alone. It is intended primarily for determining the resistance to water penetration through such assemblies for compliance with specified performance criteria, but it may also be used to determine the resistance to penetration through the joints between the assemblies and the adjacent construction. Other procedures may be appropriate to identify sources of leakage.
1.3 This test method addresses water penetration through a manufactured assembly. Water that penetrates the assembly, but does not result in a failure as defined herein, may have adverse effects on the performance of contained materials such as sealants and insulating or laminated glass. This test method does not address these issues.
1.4 The proper use of this test method requires a knowledge of the principles of pressure measurement.
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see 7.1.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on...
- Standard6 pagesEnglish language
SIGNIFICANCE AND USE
4.1 This guide is for use by individuals and entities involved with the design and specification of EIFS details for a specific building.
4.2 This guide can be applied to both EIFS-clad barrier wall assembly and EIFS-clad wall with drainage.
4.3 This guide can be applied to new and existing EIFS buildings, prefabricated versus on-site installed EIFS, and residential and commercial EIFS buildings.
4.4 This guide is not meant to replace the types of information normally present in text format in a project’s specifications.
4.5 This guide is not applicable to EIFS materials used in non EIFS applications, such as a topcoat for other base materials like traditional Portland cement plaster (stucco) and concrete.
SCOPE
1.1 This guide describes the types of project-specific construction conditions that need to be communicated by means of drawings (“details”) for the purpose of constructing Exterior Insulation and Finish System (EIFS)-clad barrier and drainage wall assemblies. EIFS manufacturers provide basic details for the installation of their materials and interface with adjacent materials. These details are generic and, in many cases, do not apply to specific project conditions.
1.2 This guide addresses only the EIFS itself and the interface between the EIFS and the materials immediately adjacent to the EIFS; it does not address all parts of the wall assembly.
1.3 Not all possible construction detail conditions are addressed by this guide. Identify and provide details for all construction conditions that exist on a specific building.
1.4 This guide is intended to supplement but not supersede information from the EIFS manufacturer about how their specific product should be detailed, nor to supersede technical product acceptance reports or the code requirements of regulatory authorities.
1.5 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Guide3 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method is a standard procedure for determining the resistance to water penetration during rapid cyclic pulses of dynamic air pressure differences. The air-pressure differences acting across a building envelope vary greatly. These factors should be fully considered prior to specifying the test pressure difference to be used.
5.2 The median test pressure used in this test method is defined as the specified test pressure supplied by the user and related to the maximum positive building design pressure. This test method departs from the format of other ASTM water penetration resistance test methods based on a maximum test pressure related to a maximum positive building design pressure.
5.3 As the specified or median test pressure is increased, the maximum test pressure in this procedure is also increased to 1.5 times the specification median test pressure. This higher maximum test pressure may not be representative of actual building service conditions. For this reason the maximum recommended median test pressure is 480 Pa (10 psf), which corresponds to a maximum test pressure of 720 Pa (15 psf).
5.4 The pulsed pressure of this test method may act to pump water past dry seals and breather systems of units incorporating these features, thereby making the test method more severe than a static pressure test method. On the other hand, the low pressure portions of the pressure cycles of this test method may allow weep systems and drainage dams to dissipate water from units incorporating these features, thereby making the test method less severe than a static pressure test method.
Note 1: In applying the results of tests by this test method, note that the performance of a wall or its components, or both, may be a function of proper installation and adjustment. In service, the performance will also depend on the rigidity of supporting construction and on the resistance of components to deterioration by various causes, (vibration, thermal expansion and ...
SCOPE
1.1 This test method covers the determination of the resistance of exterior windows, skylights, and doors to water penetration when water is applied to the outdoor face and exposed edges simultaneously with a rapid pulsed air pressure at the outdoor face higher than the pressure at the indoor face.
1.2 This test method is applicable to windows, skylights, or doors alone. Those interested in testing curtain walls to rapid pulsed air pressure differences should use AAMA 501.1-94.
1.3 This test method addresses water penetration through a manufactured assembly. Water that penetrates the assembly, but does not result in a failure as defined herein, may have adverse effects on the performance of contained materials such as sealants and insulating or laminated glass. This test method does not address these issues.
1.4 The proper use of this test method requires a knowledge of the principles of pressure measurement.
1.5 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard6 pagesEnglish language
SIGNIFICANCE AND USE
4.1 Air Leakage Relative to Sound Transmission—Certain frequencies are more susceptible to sound transmission through cavities or discontinuities in the test specimen; therefore, the air leakage of the test specimen is reported to allow the approving authority information relative to air tightness.
Note 1: The AAMA/WDMA/CSA 101/I.S.2/A440 document provides air leakage acceptance criteria for these products based on their performance class. Acoustical products could require a lower air leakage rate than what is required in this standard in order to achieve the desired acoustical performance.
4.2 Operating Force Relative to Sound Transmission—The use of specific sealing components to achieve a given sound rating could affect operating force of the vertical or horizontal sliding sash or panels of the assembly; therefore, operating force is reported to allow the approving authority information relative to sash or panel operating forces.
Note 2: The opening force in 28 CFR Part 36 ADA for interior hinged doors and sliding doors is limited to 5 lbf (22.2 N). The AAMA/WDMA/CSA 101/I.S.2/A440 document provides operating force acceptance criteria for products based on their performance class.
4.3 Latching Force Relative to Sound Transmission—Latching force can affect the compression of seals and the amount of damping applied to the system that in turn affects the air leakage and the acoustical performance. The use of specific sealing components and latching/locking hardware can affect the force required to close and latch the door under test. The latching force is reported to allow the approving authority information relative to sash or panel latching conditions.
Note 3: The AAMA/WDMA/CSA 101/I.S.2/A440 document states that the maximum force to latch shall be measured and reported.
SCOPE
1.1 This practice establishes requirements for testing and rating acoustical performance of window, door, skylight, and glazed wall systems, regardless of their method or materials of manufacture.
1.1.1 Operating force, latching force, and air leakage are integral elements of the acoustical performance of window, door, skylight, and glazed wall systems. This practice requires (when applicable) the concurrent testing of operating force, latching force, and air leakage, in addition to the sound transmission loss test.
1.2 This practice establishes the test methodology, specimen criteria, and classification rating system for purposes of determining the acoustical performance levels of window, door, skylight, and glazed wall systems only, and not through openings between such assemblies and adjacent construction.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The schedule beta (βs) approach produces informational elements: Overall (or composite) schedule beta (βs), schedule beta upside (βs+), and schedule beta downside (βs–)—representing the quantitative components, and the qualitative insight (“early warning”) into the propensity for directional schedule performance for individual schedule participants.
5.1.1 The quantitative component of schedule beta (βs) (inclusive of the upside and downside subvariants) is an index value that depicts schedule participant’s magnitude and direction of movement as compared to the overall project at an assigned value of 1.0, for example, a βs = +2.5 connotes performance of a schedule participant that moves in the same direction as the collection of completed projects at a rate of 2.5 units (schedule days) for each single unit (schedule day) experienced at the overall project level.
5.1.2 The qualitative component of schedule beta (βs) (inclusive of the upside and downside subvariants) provides insight as a cautionary and predictive signal depicting the ability for an individual schedule participant to perform in-keeping with the initially-established as-planned schedule duration(s).
5.2 Schedule beta (βs) also depicts the overall status or health (performing well or not) of a market sector, location and/or trade. Consistent larger schedule beta (βs) values are indicative of external elements (risks) impacting all participants sharing common attribute(s) (that is, trade, location, market sector, etc.).
5.3 Schedule beta (βs) measures current schedule participant performance. As a rolling value (for example, calculated for projects completed during the two most recently completed full calendar years), it depicts the schedule performance ability of the schedule participant. See Note 1.
Note 1: Schedule Data Source and Usage—Schedule beta (βs) (inclusive of the upside and downside subvariants) utilizes schedule data from any schedule calculation method that depicts individ...
SCOPE
1.1 This guide covers schedule beta (βs), which measures construction project participant schedule performance versus that of the overall completed project and is based on beta (β) from financial portfolio theory for measuring the correlation between individual stock performance and that of the overall stock market.2 By correlating the delta of actual activity performance (“as-built”) minus that originally scheduled (“as-planned”) to the delta of as-built minus as-planned for the overall completed project for a participant’s collection of projects over a specified period of time, a schedule performance index is established in a similar manner as the aforementioned beta (β) of an individual stock.
1.2 Schedule beta (βs) measures, as a unitless index value, schedule participant (“subcontractor’s”) performance—ahead or behind—as-planned duration as correlated to its respective overall project’s schedule performance.
1.3 Schedule beta (βs) is measured with input from at least two (2) independent (mutually exclusive) projects that have reached completion, within the defined period of observation.
1.4 Schedule beta (βs) is measured across a standard predetermined period of time, in similar fashion to that of the insurance industry’s experience modification rate’s (EMR) most recent two (2) complete calendar years within the past thirty-six (36) months.
1.5 Schedule beta (βs) evaluates schedule participant’s (“subcontractor’s”) most recent performance, not its complete history, such that is it indicative of current performance and contemporary influences—market, geographic, industry trade, etc.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This internation...
- Guide8 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method provides statistical (and graphical) information concerning floor surface profiles.
5.2 Results of this test method are used primarily to:
5.2.1 Establish compliance of randomly trafficked floor surfaces with specified FF Flatness and FL Levelness tolerances,
5.2.2 Evaluate the effect of different construction methods on resulting floor surface flatness and levelness, and
5.2.3 Investigate the curling and deflection of floor surfaces.
5.3 Results of this test method shall not be used to enforce contract flatness and levelness tolerances on those floor installations primarily intended to support the operation of fixed-path vehicle systems (for example, narrow aisle warehouse floors).
Note 1: When the traffic patterns across a floor are random, (as is generally the case) evaluation of the floor’s FF Flatness and FL Levelness will necessarily involve a random sampling of the surface, since all of the infinite potential profiles to be seen by the traffic can not possibly be measured. In those instances when the traffic across a floor will be confined to specific paths, however, the requirement for random sampling is eliminated, since the floor can indeed be inspected exactly as it will be seen by all of the traffic. In these special cases, rather than inferring the condition of the traffic paths from a random sample, it is far more useful to measure each of the traffic paths directly using continuous recording floor profilometer configured to run exactly in the traffic wheel paths. Such direct simulation measurements eliminate the inherent uncertainties of statistical sampling and provide profile information immediately applicable to the correction of the surface in way of the future traffic.
SCOPE
1.1 This test method covers a quantitative method of measuring floor surface profiles to obtain estimates of the floor’s characteristic FF Flatness and FL Levelness Face Floor Profile Numbers (F-Numbers).
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.3 The text of this test method references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this test method.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard9 pagesEnglish language
- Standard9 pagesEnglish language
Frequently Asked Questions
E06 is a Technical Committee within ASTM International. It is named "Performance of Buildings" and is responsible for: The promotion of knowledge, stimulation of research, development and maintenance of standards and related documents for performance of buildings, their elements, components, including means and methods of fabrication and assembly; and the description, measurement, prediction, improvement, and management of the overall performance of buildings and building-related facilities. The work of this Committee will be coordinated with other ASTM Committees and other organizations having a mutual interest. This committee has published 1377 standards.
E06 develops ASTM standards in the area of Information technology. The scope of work includes: The promotion of knowledge, stimulation of research, development and maintenance of standards and related documents for performance of buildings, their elements, components, including means and methods of fabrication and assembly; and the description, measurement, prediction, improvement, and management of the overall performance of buildings and building-related facilities. The work of this Committee will be coordinated with other ASTM Committees and other organizations having a mutual interest. Currently, there are 1377 published standards from this technical committee.
ASTM is a standardization organization that develops and publishes standards to support industry, commerce, and regulatory requirements.
A Technical Committee (TC) in ASTM is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.