E06.54 - Solid Fuel Burning Appliances
Solid Fuel Burning Appliances
General Information
ABSTRACT
This specification covers performance requirements, test methods, and marking requirements for automatic feed, pellet fuel-burning room heaters that are intended to burn wood pellets or other suitable solid fuel. Pellet fuel-burning room heaters covered by this specification are acceptable for use in manufactured homes when installed in accordance with the Manufactured Home Construction and Safety Standards published by the Department of Housing and Urban Development (HUD). The heaters shall be subject to glazing water shock test, glazing impact test, rain test, solubility test, and drop test.
SCOPE
1.1 This specification covers performance requirements, test methods, and marking requirements for automatic feed, pellet fuel-burning room heaters that are intended to burn wood pellets or other suitable solid fuel. These room heaters shall be drafted by forced or natural means.
1.2 Exhaust venting systems and associated externally mounted draft inducers are not evaluated by this specification unless they are part of an engineered system provided as part of the room heater. Parts specifically evaluated and determined to be acceptable for use with pellet fuel-burning room heaters are required to be specified in the room heater manufacturer’s instructions and are to be used in evaluating the room heater.
1.3 Pellet fuel-burning room heaters covered by this specification are intended for installation in accordance with the applicable requirements of NFPA 211 and in accordance with the applicable building and mechanical codes.
1.4 Pellet fuel-burning room heaters covered by this specification are acceptable for use in manufactured homes when installed in accordance with the Manufactured Home Construction and Safety Standards published by the Department of Housing and Urban Development (HUD). See 24 CFR Part 3280.
1.5 The terms “product” or “room heater,” as used in this specification, refer to all pellet fuel-burning room heaters or any part thereof covered by the requirements of this specification, unless specifically noted otherwise.
1.6 No information provided in this specification is intended to prevent the use of other methods or devices, provided that sufficient technical data are submitted to the authority having jurisdiction to demonstrate that the proposed method or device is equivalent in quality, strength, fire endurance, effectiveness, durability, and safety to that prescribed in this specification.
1.7 The notes incorporated into this specification are not prescriptive requirements. They are given for clarification and informational purposes only.
1.8 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.9 The following safety hazards caveat pertains only to the test methods portion, Section 10, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.10 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification19 pagesEnglish language
- Technical specification19 pagesEnglish language
ABSTRACT
This specification establishes requirements for the dimensioning of custom tiled/mortared masonry heaters (stoves) that are individually technically calculated and constructed. It is valid for masonry heaters with sidewise combustion air supply of the combustion chamber, but not for masonry heaters combined with water heat exchangers for central heating or other heat-absorbing elements such as glass plates greater than 1/6 of the combustion chamber surface, open water tanks, and so forth. This specification includes the calculation method for the dimensioning of tiled/mortared stoves.
SCOPE
1.1 This specification contains specifications for the dimensioning of custom tiled/mortared masonry heaters (stoves). The custom tiled/mortared masonry heaters (stoves) are individually technically calculated and constructed. This information can be used for log (cordwood) wood-fired masonry heaters that burn one fuel load per storage period with a maximum load between 10 kg and 40 kg and a storage period (nominal heating time) between 8 h and 24 h in accordance with EN 15544.
1.2 This specification is valid for masonry heaters equipped with fireclay as interior material with an apparent density between 1750 kg/m3 and 2200 kg/m3, a degree of porosity 18 up to 33 % by volume, and a heat conductivity from 0.65 W/mK up to 0.90 W/mK (temperature range 20 °C to 400 °C) in accordance with EN 15544.
1.3 This specification is valid for masonry heaters with sidewise combustion air supply of the combustion chamber.
1.4 This specification is not valid for masonry heaters combined with water heat exchangers for central heating or other heat-absorbing elements such as glass plates greater than 1/6 of the combustion chamber surface, open water tanks, and so forth. It is also not valid for masonry heaters combined with heating/fireplace elements in accordance with EN 13229. Furthermore, this specification is not valid for mass-produced prefabricated or partly prefabricated slow heat release appliances in accordance with EN 15250.
1.5 The calculation method of this specification is used to establish emissions and energy efficiency when burning log wood or wood briquettes in accordance with the manufacturer’s or builder’s manual.
1.6 Clearance to Combustibles—When a masonry heater is constructed in accordance with this specification, the clearance to combustibles shall be in accordance with TRVB 105 or other appropriate standards.
1.7 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification4 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method is used for determining emission factors and emission rates for low mass wood-burning fireplaces.
5.1.1 The emission factor is useful for determining emission performance during product development.
5.1.2 The emission factor is useful for the air quality regulatory community for determining compliance with emission performance limits.
5.1.3 The emission rate may be useful for the air quality regulatory community for determining impacts on air quality from fireplaces, but must be used with caution as use patterns must be factored into any prediction of atmospheric particulate matter impacts from fireplaces based on results from this method.
5.2 The reporting units are grams of particulate per kilogram of dry fuel and grams of particulate per hour.
5.2.1 Appropriate reporting units for comparing emissions from non-heating appliances: grams per kilogram.
5.2.2 Appropriate reporting units for predicting atmospheric emission impacts only if hours of fireplace use are factored in: grams per hour.
SCOPE
1.1 This test method covers the fueling and operating protocol for determining particulate matter emissions from wood fires in low mass wood-burning fireplaces. The fueling and operating protocol for determining particular matter emissions from masonry or other high mass fireplaces is covered in Annex A1 of this test method.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard18 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The measurement of particulate matter emission rates is an important test method widely used in the practice of air pollution control.
5.1.1 These measurements, when approved by federal or state agencies, are often required for the purpose of determining compliance with regulations and statutes.
5.1.2 The measurements made before and after design modifications are necessary to demonstrate the effectiveness of design changes in reducing emissions and make this standard an important tool in manufacturer’s research and development programs.
5.2 Measurement of heating efficiency provides a uniform basis for comparison of product performance that is useful to the consumer. It is also required to relate emissions produced to the useful heat production.
5.3 This is a laboratory method and is not intended to be fully representative of all actual field use. It is recognized that users of hand-fired wood burning equipment have a great deal of influence over the performance of any wood-burning appliance. Some compromises in realism have been made in the interest of providing a reliable and repeatable test method.
SCOPE
1.1 This test method applies to wood-fired or automatically fed biomass burning hydronic heating appliances. These appliances transfer heat to the indoor environment through circulation of a liquid heat exchange media such as water or a water-antifreeze mixture.
1.2 The test method simulates hand loading of seasoned cordwood or fueling with a specified biomass fuel and measures particulate emissions and delivered heating efficiency at specified heat output rates based on the appliance’s rated heating capacity.
1.3 Particulate emissions are measured by the dilution tunnel method as specified in Test Method E2515. Delivered efficiency is determined by measurement of the usable heat output (determined through measurement of the flow rate and temperature change of water circulated through a heat exchanger external to the appliance) and the heat input (determined from the mass of dry fuel burned and its higher heating value). Delivered efficiency does not attempt to account for pipeline loss.
1.4 Products covered by this test method include both pressurized and non-pressurized heating appliances intended to be fired with wood or automatically fed biomass fuels. These products are hydronic heating appliances which the manufacturer specifies for outdoor or indoor installation. They are often connected to a heat exchanger by insulated pipes and normally include a pump to circulate heated liquid. They are used to heat structures such as homes, barns, and greenhouses and can heat domestic hot water, spas, or swimming pools.
1.4.1 Hydronic heating systems that incorporate a high mass heat storage system that is capable of storing the entire heat output of a standard fuel load are tested by the procedure specified in Annex A1. Systems that incorporate high mass heat storage capable of storing a portion of the output from a standard fuel load are tested by the procedure specified in Annex A2.
1.5 Distinguishing features of products covered by this standard include:
1.5.1 Manufacturers specify indoor or outdoor installation.
1.5.2 A firebox with an access door for hand loading of fuel or a hopper and automated feed system for delivery of particulate fuel such as wood pellets or solid biomass fuel to a burn pot or combustion chamber.
1.5.3 Typically a thermostatic control device that controls combustion air supply or fuel delivery, or both, to maintain the liquid in the appliance within a predetermined temperature range provided sufficient fuel is available in the firebox or hopper.
1.5.4 A chimney or vent that exhausts combustion products from the appliance.
1.6 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not con...
- Standard19 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method is used for determining particulate matter (PM) emission rates and emission factors for wood heaters.
5.2 This method is used in conjunction with Annex A2 for determining particulate matter (PM) emissions for Single Burn Rate heaters.
5.3 Use of this test method in conjunction with Annex A1 and CSA B415.1 allows overall thermal efficiency, carbon monoxide emission rate, and particulate matter per unit of heat output to be determined.
5.4 The fuel load specified in this test method is cordwood that is representative of the fuel actually burned in homes. The intent is that the results from this test method will be more predictive of in-home performance than other test methods using a lumber crib of uniform dimensions.
SCOPE
1.1 This test method covers the fueling and operating protocol for determining average particulate matter emissions from wood fires in wood-burning room heaters and fireplace inserts as well as options for determining heat output, efficiency, and carbon monoxide emissions.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Refer to 4.3.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard19 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method is used for determining emission factors and emission rates for cordwood or other densified, binder free biomass fuel burning masonry heaters.
5.1.1 The emission factor is useful for determining emission performance during product development.
5.1.2 The emission factor is useful for the air quality regulatory community for determining compliance with emission performance limits.
5.1.3 The emission rate may be useful for the air quality regulatory community for determining impacts on air quality from masonry heaters, but must be used with caution as use patterns must be factored into any prediction of atmospheric particulate matter impacts from masonry heaters based on results from this method.
5.2 The reporting units are grams of particulate per kilogram of dry fuel (emissions factor), grams of particulate per hour of heating cycle (heating cycle emissions rate, based on the builder or manufacturer’s specified firing interval), and grams of particulate per hour of test run (combustion period emissions rate, based on the tested combustion period).
5.3 Warning—Use of masonry heater emissions rate reporting numbers (grams per hour) for comparative purposes with other solid fuel burning appliances will require careful study of each of the appliance’s comparative operating characteristics in the given application. Intermittently fired appliances such as masonry heaters and continuously fired appliances such as wood and pellet stoves are not accurately compared by their respective emissions rates.
SCOPE
1.1 This test method covers the fueling and operating protocol for determining particulate matter emissions from solid fuel biomass (cordwood or other densified, binder free biomass fuels) fires in masonry heaters. It may also be used to test other similar appliances (see 3.2.20).
1.2 This test method is applicable to the operation and fueling of masonry heaters during particulate emissions measurement test periods. The prescribed methods and procedures of these protocols are performed on masonry heaters installed and operated in accordance with the builder or manufacturer’s specifications.
1.3 In conjunction with Test Method E2515, this test method provides a protocol for laboratory emissions testing of masonry heaters that is intended to simulate actual use in residential homes and other consumer applications. Since such actual use involves almost solely cordwood fueling, Annex A1, Cordwood Fuel, provides as close a simulation as is currently possible of consumer use, and is recommended for predicting actual consumer emissions performance. For regulatory and other potential uses in comparing relative emissions of various masonry heater products and designs, Annex A2, Cribwood Fueling, and Annex A3, Cribwood Fuel, Top-Down Burn, provide optional additional fueling protocols that substitute dimensional lumber cribs for the cordwood fuel. Data that establish the relationships between the emissions results generated by Annex A2 and Annex A3 and the emissions results generated by Annex A1 are not currently available.
1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard22 pagesEnglish language
SCOPE
1.1 This test method is applicable for the determination of particulate matter emissions from solid-fuel-burning appliances including woodstoves, pellet-burning appliances, factory-built fireplaces, masonry fireplaces, masonry heaters, indoor furnaces, and indoor and outdoor hydronic heaters within a laboratory environment.
1.2 Analytes will be a particulate matter (PM) with no CAS number assigned. For data quality objectives, see Appendix X1.
1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.4 This test method does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard15 pagesEnglish language
SIGNIFICANCE AND USE
4.1 This guide can be used by code officials, architects, and other interested parties to evaluate the design and construction of masonry heaters. It is not restricted to a specific method of construction, nor does it provide all specific details of construction of a masonry heater. This guide does provide the principles to be followed for the safe construction of masonry heaters.
4.2 This guide is not intended as a complete set of directions for construction of masonry heaters.
4.3 Construction of masonry heaters is complex, and in order to ensure their safety and performance, construction shall be done by or under the supervision of a skilled and experienced masonry heater builder.5
SCOPE
1.1 This guide covers the design and construction of solid fuel burning masonry heaters. It provides dimensions for site constructed masonry heater components and clearances that have been derived by experience and found to be consistent with the safe installation of those masonry heaters.
1.2 Values given in SI units are to be regarded as standard. Inch/pound units may be rounded (see IEEE/ASTM SI-10). All dimensions are nominal unless specifically stated otherwise. All clearances listed in this guide are actual dimensions.
1.3 This guide applies to the design and construction of masonry heaters built on-site with the components and materials specified herein. It does not apply to the construction/installation requirements for component systems that have been safety tested and listed. The requirements for listed masonry heater systems are specified in the manufacturer’s installation instructions.
1.4 The design and construction of solid fuel burning masonry heaters shall comply with applicable building codes.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Guide9 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method is used for determining average emission rates and average emission factors for pellet heaters.
5.1.1 The emission factor is useful for determining emission performance during product development.
5.1.2 The emission factor is useful for the air quality regulatory community for determining compliance with emission performance limits.
5.1.3 The emission rate may be useful for the air quality regulatory community for determining impacts on air quality from pellet heaters.
5.2 The reporting units are grams of particulate per hour and grams of particulate per kilogram of dry fuel.
5.2.1 Appropriate reporting units for comparing emissions from all types of solid fuel fired appliances: g/kg.
5.2.2 Appropriate reporting units for predicting atmospheric emission impacts: g/h or g/MJ.
SCOPE
1.1 This test method covers the fueling and operating protocol for determining particulate matter emissions from fires in pellet or other granular or particulate biomass burning room heaters and fireplace inserts.
1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard7 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method is used for determining emission rates and emission factors for wood heaters.
5.1.1 The emission factor is useful for determining emission performance during product development.
5.1.2 The emission factor is useful for the air quality regulatory community for determining compliance with emission performance limits.
5.1.3 The emission rate may be useful for the air quality regulatory community for determining impacts on air quality from wood heaters.
5.2 The reporting units are grams of particulate per hour, grams of particulate per kilogram of dry fuel and grams of particulate per megajoule of heat output.
5.2.1 Appropriate reporting units for comparing emissions from all types of solid fuel fired appliances: g/kg.
5.2.2 Appropriate reporting units for predicting atmospheric emission impacts: g/h or g/MJ.
5.3 The fuel load specified in this test method is a lumber crib of uniform dimensions, identical to that specified in EPA Method 28. Cribs were specified in EPA Method 28 to provide a reproducible and repeatable test method. In normal operation the majority of fuel used by consumers is cordwood with irregular shapes and dimensions. Very little data exists to indicate whether or not the fuel cribs specified in this standard yield results that are predictive of performance using cordwood fuel. This standard, therefore, includes Annex A1 which provides a fueling procedure using cordwood. It is provided so that those interested in measuring emissions performance with cordwood will have a consistent method to follow. A comparative database using the two fueling procedures will provide data to determine whether test results using crib fuel correlate to test results using cordwood fuel.
SCOPE
1.1 This test method covers the fueling and operating protocol for determining particulate matter emissions from wood fires in wood-burning room heaters and fireplace inserts as well as determining heat output and efficiency.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard13 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method is used for determining particulate matter (PM) emission rates and emission factors for wood heaters.
5.2 This method is used in conjunction with Annex A2 for determining particulate matter (PM) emissions for Single Burn Rate heaters.
5.3 Use of this test method in conjunction with Annex A1 and CSA B415.1 allows overall thermal efficiency, carbon monoxide emission rate, and particulate matter per unit of heat output to be determined.
5.4 The fuel load specified in this test method is cordwood that is representative of the fuel actually burned in homes. The intent is that the results from this test method will be more predictive of in-home performance than other test methods using a lumber crib of uniform dimensions.
SCOPE
1.1 This test method covers the fueling and operating protocol for determining average particulate matter emissions from wood fires in wood-burning room heaters and fireplace inserts as well as options for determining heat output, efficiency, and carbon monoxide emissions.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Refer to 4.3.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard19 pagesEnglish language
- Standard19 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method is used for determining particulate matter (PM) emission rates and emission factors for wood heaters.
5.2 This method is used in conjunction with Annex A2 for determining particulate matter (PM) emissions for Single Burn Rate heaters.
5.3 Use of this test method in conjunction with Annex A1 and CSA B415.1 allows overall thermal efficiency, carbon monoxide emission rate, and particulate matter per unit of heat output to be determined.
5.4 The fuel load specified in this test method is cordwood that is representative of the fuel actually burned in homes. The intent is that the results from this test method will be more predictive of in-home performance than other test methods using a lumber crib of uniform dimensions.
SCOPE
1.1 This test method covers the fueling and operating protocol for determining average particulate matter emissions from wood fires in wood-burning room heaters and fireplace inserts as well as options for determining heat output, efficiency, and carbon monoxide emissions.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Refer to 4.3.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard19 pagesEnglish language
- Standard19 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method is used for determining particulate matter (PM) emission rates and emission factors for wood heaters.
5.2 This method is used in conjunction with Annex A2 for determining particulate matter (PM) emissions for Single Burn Rate heaters.
5.3 Use of this test method in conjunction with Annex A1 and CSA B415.1 allows overall thermal efficiency, carbon monoxide emission rate, and particulate matter per unit of heat output to be determined.
5.4 The fuel load specified in this test method is cordwood that is representative of the fuel actually burned in homes. The intent is that the results from this test method will be more predictive of in-home performance than other test methods using a lumber crib of uniform dimensions.
SCOPE
1.1 This test method covers the fueling and operating protocol for determining average particulate matter emissions from wood fires in wood-burning room heaters and fireplace inserts as well as options for determining heat output, efficiency, and carbon monoxide emissions.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Refer to 4.3.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard19 pagesEnglish language
ABSTRACT
This specification covers performance requirements, test methods, and marking requirements for automatic feed, pellet fuel-burning room heaters that are intended to burn wood pellets or other suitable solid fuel. Pellet fuel-burning room heaters covered by this specification are acceptable for use in manufactured homes when installed in accordance with the Manufactured Home Construction and Safety Standards published by the Department of Housing and Urban Development (HUD). The heaters shall be subject to glazing water shock test, glazing impact test, rain test, solubility test, and drop test.
SCOPE
1.1 This specification covers performance requirements, test methods, and marking requirements for automatic feed, pellet fuel-burning room heaters that are intended to burn wood pellets or other suitable solid fuel. These room heaters shall be drafted by forced or natural means.
1.2 Exhaust venting systems and associated externally mounted draft inducers are not evaluated by this specification unless they are part of an engineered system provided as part of the room heater. Parts specifically evaluated and determined to be acceptable for use with pellet fuel-burning room heaters are required to be specified in the room heater manufacturer’s instructions and are to be used in evaluating the room heater.
1.3 Pellet fuel-burning room heaters covered by this specification are intended for installation in accordance with the applicable requirements of NFPA 211 and in accordance with the applicable building and mechanical codes.
1.4 Pellet fuel-burning room heaters covered by this specification are acceptable for use in manufactured homes when installed in accordance with the Manufactured Home Construction and Safety Standards published by the Department of Housing and Urban Development (HUD). See 24 CFR 3280.
1.5 The terms “product” or “room heater,” as used in this specification, refer to all pellet fuel-burning room heaters or any part thereof covered by the requirements of this specification, unless specifically noted otherwise.
1.6 No information provided in this specification is intended to prevent the use of other methods or devices, provided that sufficient technical data are submitted to the authority having jurisdiction to demonstrate that the proposed method or device is equivalent in quality, strength, fire endurance, effectiveness, durability, and safety to that prescribed in this specification.
1.7 The notes incorporated into this specification are not prescriptive requirements. They are given for clarification and informational purposes only.
1.8 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.9 The following safety hazards caveat pertains only to the test methods portion, Section 10, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.10 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification19 pagesEnglish language
- Technical specification19 pagesEnglish language
ABSTRACT
This specification establishes requirements for the dimensioning of custom tiled/mortared masonry heaters (stoves) that are individually technically calculated and constructed. It is valid for masonry heaters with sidewise combustion air supply of the combustion chamber, but not for masonry heaters combined with water heat exchangers for central heating or other heat-absorbing elements such as glass plates greater than 1/6 of the combustion chamber surface, open water tanks, and so forth. This specification includes the calculation method for the dimensioning of tiled/mortared stoves.
SCOPE
1.1 This specification contains specifications for the dimensioning of custom tiled/mortared masonry heaters (stoves). The custom tiled/mortared masonry heaters (stoves) are individually technically calculated and constructed. This information can be used for log (cordwood) wood-fired masonry heaters that burn one fuel load per storage period with a maximum load between 10 and 40 kg and a storage period (nominal heating time) between 8 and 24 h per EN 15544.
1.2 This specification is valid for masonry heaters equipped with fireclay as interior material with an apparent density between 1750 and 2200 kg/m³, a degree of porosity 18 up to 33 % by volume, and a heat conductivity from 0.65 up to 0.90 W/mK (temperature range 20 to 400°C) per EN 15544.
1.3 This specification is valid for masonry heaters with sidewise combustion air supply of the combustion chamber.
1.4 This specification is not valid for masonry heaters combined with water heat exchangers for central heating or other heat-absorbing elements such as glass plates greater than 1/6 of the combustion chamber surface, open water tanks, and so forth. It is also not valid for masonry heaters combined with heating/fireplace elements in accordance with EN 13229. Furthermore, this specification is not valid for mass-produced prefabricated or partly prefabricated slow heat release appliances according to EN 15250.
1.5 The calculation method of this specification is used to establish emissions and energy efficiency when burning log wood or wood briquettes according to the manufacturer’s or builder’s manual.
1.6 Clearance to Combustibles—When a masonry heater is constructed according to this specification, the clearance to combustibles shall be in accordance with TRVB 105 or other appropriate standards.
1.7 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Technical specification4 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The measurement of particulate matter emission rates is an important test method widely used in the practice of air pollution control.
5.1.1 These measurements, when approved by federal or state agencies, are often required for the purpose of determining compliance with regulations and statutes.
5.1.2 The measurements made before and after design modifications are necessary to demonstrate the effectiveness of design changes in reducing emissions and make this standard an important tool in manufacturer’s research and development programs.
5.2 Measurement of heating efficiency provides a uniform basis for comparison of product performance that is useful to the consumer. It is also required to relate emissions produced to the useful heat production.
5.3 This is a laboratory method and is not intended to be fully representative of all actual field use. It is recognized that users of hand-fired wood burning equipment have a great deal of influence over the performance of any wood-burning appliance. Some compromises in realism have been made in the interest of providing a reliable and repeatable test method.
SCOPE
1.1 This test method applies to wood-fired or automatically fed biomass burning hydronic heating appliances. These appliances transfer heat to the indoor environment through circulation of a liquid heat exchange media such as water or a water-antifreeze mixture.
1.2 The test method simulates hand loading of seasoned cordwood or fueling with a specified biomass fuel and measures particulate emissions and delivered heating efficiency at specified heat output rates based on the appliance’s rated heating capacity.
1.3 Particulate emissions are measured by the dilution tunnel method as specified in Test Method E2515. Delivered efficiency is determined by measurement of the usable heat output (determined through measurement of the flow rate and temperature change of water circulated through a heat exchanger external to the appliance) and the heat input (determined from the mass of dry fuel burned and its higher heating value). Delivered efficiency does not attempt to account for pipeline loss.
1.4 Products covered by this test method include both pressurized and non-pressurized heating appliances intended to be fired with wood or automatically fed biomass fuels. These products are hydronic heating appliances which the manufacturer specifies for outdoor or indoor installation. They are often connected to a heat exchanger by insulated pipes and normally include a pump to circulate heated liquid. They are used to heat structures such as homes, barns, and greenhouses and can heat domestic hot water, spas, or swimming pools.
1.4.1 Hydronic heating systems that incorporate a high mass heat storage system that is capable of storing the entire heat output of a standard fuel load are tested by the procedure specified in Annex A1. Systems that incorporate high mass heat storage capable of storing a portion of the output from a standard fuel load are tested by the procedure specified in Annex A2.
1.5 Distinguishing features of products covered by this standard include:
1.5.1 Manufacturers specify indoor or outdoor installation.
1.5.2 A firebox with an access door for hand loading of fuel or a hopper and automated feed system for delivery of particulate fuel such as wood pellets or solid biomass fuel to a burn pot or combustion chamber.
1.5.3 Typically a thermostatic control device that controls combustion air supply or fuel delivery, or both, to maintain the liquid in the appliance within a predetermined temperature range provided sufficient fuel is available in the firebox or hopper.
1.5.4 A chimney or vent that exhausts combustion products from the appliance.
1.6 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not con...
- Standard19 pagesEnglish language
- Standard19 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method is used for determining emission factors and emission rates for low mass wood-burning fireplaces.
5.1.1 The emission factor is useful for determining emission performance during product development.
5.1.2 The emission factor is useful for the air quality regulatory community for determining compliance with emission performance limits.
5.1.3 The emission rate may be useful for the air quality regulatory community for determining impacts on air quality from fireplaces, but must be used with caution as use patterns must be factored into any prediction of atmospheric particulate matter impacts from fireplaces based on results from this method.
5.2 The reporting units are grams of particulate per kilogram of dry fuel and grams of particulate per hour.
5.2.1 Appropriate reporting units for comparing emissions from non-heating appliances: g/kg.
5.2.2 Appropriate reporting units for predicting atmospheric emission impacts only if hours of fireplace use are factored in: g/h.
SCOPE
1.1 This test method covers the fueling and operating protocol for determining particulate matter emissions from wood fires in low mass wood-burning fireplaces. The fueling and operating protocol for determining particular matter emissions from masonry or other high mass fireplaces is covered in Annex A1 of this test method.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard18 pagesEnglish language
- Standard18 pagesEnglish language
ABSTRACT
This specification covers performance requirements, test methods, and marking requirements for automatic feed, pellet fuel-burning room heaters that are intended to burn wood pellets or other suitable solid fuel. Pellet fuel-burning room heaters covered by this specification are acceptable for use in manufactured homes when installed in accordance with the Manufactured Home Construction and Safety Standards published by the Department of Housing and Urban Development (HUD). The heaters shall be subject to glazing water shock test, glazing impact test, rain test, solubility test, and drop test.
SCOPE
1.1 This specification covers performance requirements, test methods, and marking requirements for automatic feed, pellet fuel-burning room heaters that are intended to burn wood pellets or other suitable solid fuel. These room heaters shall be drafted by forced or natural means.
1.2 Exhaust venting systems and associated externally mounted draft inducers are not evaluated by this specification unless they are part of an engineered system provided as part of the room heater. Parts specifically evaluated and determined to be acceptable for use with pellet fuel-burning room heaters are required to be specified in the room heater manufacturer's instructions and are to be used in evaluating the room heater.
1.3 Pellet fuel-burning room heaters covered by this specification are intended for installation in accordance with the applicable requirements of NFPA 211 and in accordance with the applicable building and mechanical codes.
1.4 Pellet fuel-burning room heaters covered by this specification are acceptable for use in manufactured homes when installed in accordance with the Manufactured Home Construction and Safety Standards published by the Department of Housing and Urban Development (HUD). See 24 CFR 3280.
1.5 The terms “product” or “room heater,” as used in this specification, refer to all pellet fuel-burning room heaters or any part thereof covered by the requirements of this specification, unless specifically noted otherwise.
1.6 No information provided in this specification is intended to prevent the use of other methods or devices, provided that sufficient technical data are submitted to the authority having jurisdiction to demonstrate that the proposed method or device is equivalent in quality, strength, fire endurance, effectiveness, durability, and safety to that prescribed in this specification.
1.7 The notes incorporated into this specification are not prescriptive requirements. They are given for clarification and informational purposes only.
1.8 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.9 The following safety hazards caveat pertains only to the test methods portion, Section 10, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Technical specification19 pagesEnglish language
- Technical specification19 pagesEnglish language
SCOPE
1.1 This test method is applicable for the determination of particulate matter emissions from solid-fuel-burning appliances including woodstoves, pellet-burning appliances, factory-built fireplaces, masonry fireplaces, masonry heaters, indoor furnaces, and indoor and outdoor hydronic heaters within a laboratory environment.
1.2 Analytes will be a particulate matter (PM) with no CAS number assigned. For data quality objectives, see Appendix X1.
1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.4 This test method does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard15 pagesEnglish language
- Standard15 pagesEnglish language
SIGNIFICANCE AND USE
This test method is used for determining emission factors and emission rates for cordwood or other densified, binder free biomass fuel burning masonry heaters.
The emission factor is useful for determining emission performance during product development.
The emission factor is useful for the air quality regulatory community for determining compliance with emission performance limits.
The emission rate may be useful for the air quality regulatory community for determining impacts on air quality from masonry heaters, but must be used with caution as use patterns must be factored into any prediction of atmospheric particulate matter impacts from masonry heaters based on results from this method.
The reporting units are grams of particulate per kilogram of dry fuel (emissions factor), grams of particulate per hour of heating cycle (heating cycle emissions rate, based on the builder or manufacturer’s specified firing interval), and grams of particulate per hour of test run (combustion period emissions rate, based on the tested combustion period).
Warning—Use of masonry heater emissions rate reporting numbers (grams per hour) for comparative purposes with other solid fuel burning appliances will require careful study of each of the appliance’s comparative operating characteristics in the given application. Intermittently fired appliances such as masonry heaters and continuously fired appliances such as wood and pellet stoves are not accurately compared by their respective emissions rates.
SCOPE
1.1 This test method covers the fueling and operating protocol for determining particulate matter emissions from solid fuel biomass (cordwood or other densified, binder free biomass fuels) fires in masonry heaters. It may also be used to test other similar appliances (see 3.2.20).
1.2 This test method is applicable to the operation and fueling of masonry heaters during particulate emissions measurement test periods. The prescribed methods and procedures of these protocols are performed on masonry heaters installed and operated in accordance with the builder or manufacturer’s specifications.
1.3 In conjunction with Test Method E2515, this test method provides a protocol for laboratory emissions testing of masonry heaters that is intended to simulate actual use in residential homes and other consumer applications. Since such actual use involves almost solely cordwood fueling, Annex A1, Cordwood Fuel, provides as close a simulation as is currently possible of consumer use, and is recommended for predicting actual consumer emissions performance. For regulatory and other potential uses in comparing relative emissions of various masonry heater products and designs, Annex A2, Cribwood Fueling, and Annex A3, Cribwood Fuel, Top-Down Burn, provide optional additional fueling protocols that substitute dimensional lumber cribs for the cordwood fuel. Data that establish the relationships between the emissions results generated by Annex A2 and Annex A3 and the emissions results generated by Annex A1 are not currently available.
1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard21 pagesEnglish language
SIGNIFICANCE AND USE
This test method is used for determining average emission rates and average emission factors for pellet heaters.
The emission factor is useful for determining emission performance during product development.
The emission factor is useful for the air quality regulatory community for determining compliance with emission performance limits.
The emission rate may be useful for the air quality regulatory community for determining impacts on air quality from pellet heaters.
The reporting units are grams of particulate per hour and grams of particulate per kilogram of dry fuel.
Appropriate reporting units for comparing emissions from all types of solid fuel fired appliances: g/kg.
Appropriate reporting units for predicting atmospheric emission impacts: g/h or g/MJ.
SCOPE
1.1 This test method covers the fueling and operating protocol for determining particulate matter emissions from fires in pellet or other granular or particulate biomass burning room heaters and fireplace inserts.
1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard6 pagesEnglish language
SIGNIFICANCE AND USE
This test method is used for determining emission rates and emission factors for wood heaters.
The emission factor is useful for determining emission performance during product development.
The emission factor is useful for the air quality regulatory community for determining compliance with emission performance limits.
The emission rate may be useful for the air quality regulatory community for determining impacts on air quality from wood heaters.
The reporting units are grams of particulate per hour, grams of particulate per kilogram of dry fuel and grams of particulate per megajoule of heat output.
Appropriate reporting units for comparing emissions from all types of solid fuel fired appliances: g/kg.
Appropriate reporting units for predicting atmospheric emission impacts: g/h or g/MJ.
The fuel load specified in this test method is a lumber crib of uniform dimensions, identical to that specified in EPA Method 28. Cribs were specified in EPA Method 28 to provide a reproducible and repeatable test method. In normal operation the majority of fuel used by consumers is cordwood with irregular shapes and dimensions. Very little data exists to indicate whether or not the fuel cribs specified in this standard yield results that are predictive of performance using cordwood fuel. This standard, therefore, includes Annex A1 which provides a fueling procedure using cordwood. It is provided so that those interested in measuring emissions performance with cordwood will have a consistent method to follow. A comparative database using the two fueling procedures will provide data to determine whether test results using crib fuel correlate to test results using cordwood fuel.
SCOPE
1.1 This test method covers the fueling and operating protocol for determining particulate matter emissions from wood fires in wood-burning room heaters and fireplace inserts as well as determining heat output and efficiency.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard13 pagesEnglish language
SCOPE
1.1 This test method is applicable for the determination of particulate matter emissions from solid-fuel-burning appliances including woodstoves, pellet-burning appliances, factory-built fireplaces, masonry fireplaces, masonry heaters, indoor furnaces, and indoor and outdoor hydronic heaters within a laboratory environment.
1.2 Analytes will be a particulate matter (PM) with no CAS number assigned. For data quality objectives, see Appendix X1.
1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.4 This test method does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard15 pagesEnglish language
- Standard15 pagesEnglish language
SIGNIFICANCE AND USE
This guide can be used by code officials, architects, and other interested parties to evaluate the design and construction of masonry heaters. It is not restricted to a specific method of construction, nor does it provide all specific details of construction of a masonry heater. This guide does provide the principles to be followed for the safe construction of masonry heaters.
This guide is not intended as a complete set of directions for construction of masonry heaters.
Construction of masonry heaters is complex, and in order to ensure their safety and performance, construction shall be done by or under the supervision of a skilled and experienced masonry heater builder.
SCOPE
1.1 This guide covers the design and construction of solid fuel burning masonry heaters. It provides dimensions for site constructed masonry heater components and clearances that have been derived by experience and found to be consistent with the safe installation of those masonry heaters.
1.2 Values given in SI units are to be regarded as standard. Inch/pound units may be rounded (see ). All dimensions are nominal unless specifically stated otherwise. All clearances listed in this guide are actual dimensions.
1.3 This guide applies to the design and construction of masonry heaters built on-site with the components and materials specified herein. It does not apply to the construction/installation requirements for component systems that have been safety tested and listed. The requirements for listed masonry heater systems are specified in the manufacturer's installation instructions.
1.4 The design and construction of solid fuel burning masonry heaters shall comply with applicable building codes.
- Guide9 pagesEnglish language
SIGNIFICANCE AND USE
This test method is used for determining emission factors and emission rates for low mass wood-burning fireplaces.
The emission factor is useful for determining emission performance during product development.
The emission factor is useful for the air quality regulatory community for determining compliance with emission performance limits.
The emission rate may be useful for the air quality regulatory community for determining impacts on air quality from fireplaces, but must be used with caution as use patterns must be factored into any prediction of atmospheric particulate matter impacts from fireplaces based on results from this method.
The reporting units are grams of particulate per kilogram of dry fuel and grams of particulate per hour.
Appropriate reporting units for comparing emissions from non-heating appliances: g/kg.
Appropriate reporting units for predicting atmospheric emission impacts only if hours of fireplace use are factored in: g/h.
SCOPE
1.1 This test method covers the fueling and operating protocol for determining particulate matter emissions from wood fires in low mass wood-burning fireplaces.
1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard17 pagesEnglish language
- Standard17 pagesEnglish language
SCOPE
1.1 This test method is applicable for the determination of particulate matter emissions from solid-fuel-burning appliances including woodstoves, pellet-burning appliances, factory-built fireplaces, masonry fireplaces, masonry heaters, indoor furnaces, and indoor and outdoor hydronic heaters within a laboratory environment.
1.2 Analytes will be a particulate matter (PM) with no CAS number assigned. For data quality objectives, see Appendix X1.
1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.4 This test method does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard15 pagesEnglish language
- Standard15 pagesEnglish language
SIGNIFICANCE AND USE
The measurement of particulate matter emission rates is an important test method widely used in the practice of air pollution control.
These measurements, when approved by federal or state agencies, are often required for the purpose of determining compliance with regulations and statutes.
The measurements made before and after design modifications are necessary to demonstrate the effectiveness of design changes in reducing emissions and make this standard an important tool in manufacturer’s research and development programs.
Measurement of heating efficiency provides a uniform basis for comparison of product performance that is useful to the consumer. It is also required to relate emissions produced to the useful heat production.
This is a laboratory method and is not intended to be fully representative of all actual field use. It is recognized that users of hand-fired wood burning equipment have a great deal of influence over the performance of any wood-burning appliance. Some compromises in realism have been made in the interest of providing a reliable and repeatable test method.
SCOPE
1.1 This test method applies to wood-fired or automatically fed biomass burning hydronic heating appliances, which the manufacturer specifies for outdoor installation or in structures not normally occupied by humans. These appliances transfer heat to the indoor environment through circulation of a liquid heat exchange media such as water or a water-antifreeze mixture.
1.2 The test method simulates hand loading of seasoned cordwood or fueling with a specified biomass fuel and measures particulate emissions and delivered heating efficiency at specified heat output rates based on the appliance’s rated heating capacity.
1.3 Particulate emissions are measured by the dilution tunnel method as specified in Test Method E 2515. Delivered efficiency is measured by determining the heat output through measurement of the flow rate and temperature change of water circulated through a heat exchanger external to the appliance and determining the input from the mass of dry fuel and its higher heating value. Delivered efficiency does not attempt to account for pipeline loss.
1.4 Products covered by this test method include both pressurized and non-pressurized heating appliances intended to be fired with wood or automatically fed biomass fuels. These products are hydronic heating appliances which the manufacturer specifies for outdoor installation or in structures not normally occupied by humans. They are often connected to an indoor heat exchanger by insulated pipes buried in the ground and normally include a pump to circulate heated liquid. They are used to heat structures such as homes, barns, and greenhouses and can heat domestic hot water, spas, or swimming pools.
1.5 Distinguishing features of products covered by this standard include:
1.5.1 Manufacturers specify outdoor installation or installation in structures not normally occupied by humans.
1.5.2 A firebox with an access door for hand loading of fuel or a hopper and automated feed system for delivery of particulate fuel such as wood pellets or solid biomass fuel to a burn pot or combustion chamber.
1.5.3 Typically a thermostatic control device that controls combustion air supply or fuel delivery, or both, to maintain the liquid in the appliance within a predetermined temperature range provided sufficient fuel is available in the firebox or hopper.
1.5.4 A chimney or vent that exhausts combustion products from the appliance.
1.6 The values stated are to be regarded as the standard whether in inch-pound or SI units. The values given in parentheses are for information only.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations...
- Standard13 pagesEnglish language
- Standard13 pagesEnglish language
SIGNIFICANCE AND USE
The measurement of particulate matter emission rates is an important test method widely used in the practice of air pollution control.
These measurements, when approved by federal or state agencies, are often required for the purpose of determining compliance with regulations and statutes.
The measurements made before and after design modifications are necessary to demonstrate the effectiveness of design changes in reducing emissions and make this standard an important tool in manufacturer’s research and development programs.
Measurement of heating efficiency provides a uniform basis for comparison of product performance that is useful to the consumer. It is also required to relate emissions produced to the useful heat production.
This is a laboratory method and is not intended to be fully representative of all actual field use. It is recognized that users of hand-fired wood burning equipment have a great deal of influence over the performance of any wood-burning appliance. Some compromises in realism have been made in the interest of providing a reliable and repeatable test method.
SCOPE
1.1 This test method applies to wood-fired or automatically fed biomass burning hydronic heating appliances, which the manufacturer specifies for outdoor installation or in structures not normally occupied by humans. These appliances transfer heat to the indoor environment through circulation of a liquid heat exchange media such as water or a water-antifreeze mixture.
1.2 The test method simulates hand loading of seasoned cordwood or fueling with a specified biomass fuel and measures particulate emissions and delivered heating efficiency at specified heat output rates based on the appliance’s rated heating capacity.
1.3 Particulate emissions are measured by the dilution tunnel method as specified in Test Method E 2515. Delivered Efficiency is measured by determining the heat output through measurement of the flow rate and temperature change of water circulated through a heat exchanger external to the appliance and determining the input from the mass of dry fuel and its higher heating value. Delivered efficiency does not attempt to account for pipeline loss.
1.4 Products covered by this test method include both pressurized and non-pressurized heating appliances intended to be fired with wood or automatically fed biomass fuels. These products are hydronic heating appliances which the manufacturer specifies for outdoor installation or in structures not normally occupied by humans. They are often connected to an indoor heat exchanger by insulated pipes buried in the ground and normally include a pump to circulate heated liquid. They are used to heat structures such as homes, barns, and greenhouses and can heat domestic hot water, spas, or swimming pools.
1.5 Distinguishing features of products covered by this standard include:
1.5.1 Manufacturers specify outdoor installation or installation in structures not normally occupied by humans.
1.5.2 A firebox with an access door for hand loading of fuel or a hopper and automated feed system for delivery of particulate fuel such as wood pellets or solid biomass fuel to a burn pot or combustion chamber.
1.5.3 Typically a thermostatic control device that controls combustion air supply or fuel delivery, or both, to maintain the liquid in the appliance within a predetermined temperature range provided sufficient fuel is available in the firebox or hopper.
1.5.4 A chimney or vent that exhausts combustion products from the appliance.
1.6 The values stated are to be regarded as the standard whether in inch-pound or SI units. The values given in parentheses are for information only.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitatio...
- Standard9 pagesEnglish language
SIGNIFICANCE AND USE
This test method is used for determining emission factors and emission rates for low mass wood-burning fireplaces.
The emission factor is useful for determining emission performance during product development.
The emission factor is useful for the air quality regulatory community for determining compliance with emission performance limits.
The emission rate may be useful for the air quality regulatory community for determining impacts on air quality from fireplaces, but must be used with caution as use patterns must be factored into any prediction of atmospheric particulate matter impacts from fireplaces based on results from this method.
The reporting units are grams of particulate per kilogram of dry fuel and grams of particulate per hour.
Appropriate reporting units for comparing emissions from non-heating appliances: g/kg.
Appropriate reporting units for predicting atmospheric emission impacts only if hours of fireplace use are factored in: g/h.
SCOPE
1.1 This test method covers the fueling and operating protocol for determining particulate matter emissions from wood fires in low mass wood-burning fireplaces.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard15 pagesEnglish language
- Standard15 pagesEnglish language
SCOPE
1.1 This test method is applicable for the determination of particulate matter emissions from solid-fuel-burning appliances including woodstoves, pellet-burning appliances, factory-built fireplaces, masonry fireplaces, masonry heaters, and outdoor hydronic heaters within a laboratory environment.
1.2 Analytes will be a particulate matter (PM) with no CAS number assigned. For data quality objectives, see Appendix X1.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 This test method does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard14 pagesEnglish language
SCOPE
1.1 This test method covers the fueling and operating protocol for determining particulate matter emissions from wood fires in low mass wood-burning fireplaces.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard12 pagesEnglish language
SIGNIFICANCE AND USE
This test method is used for determining emission factors and emission rates for low mass wood-burning fireplaces.
5.1.1 The emission factor is useful for determining emission performance during product development.
5.1.2 The emission factor is useful for the air quality regulatory community for determining compliance with emission performance limits.
5.1.3 The emission rate may be useful for the air quality regulatory community for determining impacts on air quality from fireplaces, but must be used with caution as use patterns must be factored into any prediction of atmospheric particulate matter impacts from fireplaces based on results from this method.
The reporting units are grams of particulate per kilogram of dry fuel and grams of particulate per hour.
5.2.1 Appropriate reporting units for comparing emissions from non-heating appliances: g/kg.
5.2.2 Appropriate reporting units for predicting atmospheric emission impacts only if hours of fireplace use are factored in: g/hour.
SCOPE
1.1 This test method covers the fueling and operating protocol for determining particulate matter emissions from wood fires in low mass wood-burning fireplaces.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Standard13 pagesEnglish language
ABSTRACT
This specification covers performance requirements, test methods, and marking requirements for automatic feed, pellet fuel-burning room heaters that are intended to burn wood pellets or other suitable solid fuel. Pellet fuel-burning room heaters covered by this specification are acceptable for use in manufactured homes when installed in accordance with the Manufactured Home Construction and Safety Standards published by the Department of Housing and Urban Development (HUD). The heaters shall be subject to glazing water shock test, glazing impact test, rain test, solubility test, and drop test.
SCOPE
1.1 This specification covers performance requirements, test methods, and marking requirements for automatic feed, pellet fuel-burning room heaters that are intended to burn wood pellets or other suitable solid fuel. These room heaters shall be drafted by forced or natural means.
1.2 Exhaust venting systems and associated externally mounted draft inducers are not evaluated by this specification unless they are part of an engineered system provided as part of the room heater. Parts specifically evaluated and determined to be acceptable for use with pellet fuel-burning room heaters are required to be specified in the room heater manufacturer's instructions and are to be used in evaluating the room heater.
1.3 Pellet fuel-burning room heaters covered by this specification are intended for installation in accordance with the applicable requirements of NFPA 211 and in accordance with the applicable building and mechanical codes.
1.4 Pellet fuel-burning room heaters covered by this specification are acceptable for use in manufactured homes when installed in accordance with the Manufactured Home Construction and Safety Standards published by the Department of Housing and Urban Development (HUD). See 24 CFR 3280.
1.5 The terms "product" or "room heater," as used in this specification, refer to all pellet fuel-burning room heaters or any part thereof covered by the requirements of this specification, unless specifically noted otherwise.
1.6 No information provided in this specification is intended to prevent the use of other methods or devices, provided that sufficient technical data are submitted to the authority having jurisdiction to demonstrate that the proposed method or device is equivalent in quality, strength, fire endurance, effectiveness, durability, and safety to that prescribed in this specification.
1.7 The notes incorporated into this specification are not prescriptive requirements. They are given for clarification and informational purposes only.
1.8 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.9 The following safety hazards caveat pertains only to the test methods portion, Section , of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Technical specification18 pagesEnglish language
SIGNIFICANCE AND USE
This guide can be used by code officials, architects, and other interested parties to evaluate the design and construction of masonry heaters. It is not restricted to a specific method of construction, nor does it provide all specific details of construction of a masonry heater. This guide does provide the principles to be followed for the safe construction of masonry heaters.
This guide is not intended as a complete set of directions for construction of masonry heaters.
Construction of masonry heaters is complex, and in order to ensure their safety and performance, construction shall be done by or under the supervision of a skilled and experienced masonry heater builder.4
SCOPE
1.1 This guide covers the design and construction of solid fuel burning masonry heaters. It provides dimensions for site constructed masonry heater components and clearances that have been derived by experience and found to be consistent with the safe installation of those masonry heaters.
1.2 Values given in SI units are to be regarded as standard. Inch/pound units may be rounded (see IEEE/ASTM SI-10). All dimensions are nominal unless specifically stated otherwise. All clearances listed in this guide are actual dimensions.
1.3 This guide applies to the design and construction of masonry heaters built on-site with the components and materials specified herein. It does not apply to the construction/installation requirements for component systems that have been safety tested and listed. The requirements for listed masonry heater systems are specified in the manufacturer's installation instructions.
1.4 The design and construction of solid fuel burning masonry heaters shall comply with applicable building codes.
- Guide9 pagesEnglish language
- Guide9 pagesEnglish language
SCOPE
1.1 This guide covers the design and construction of solid fuel burning masonry heaters. It provides dimensions for site constructed masonry heater components and clearances that have been derived by experience and found to be consistent with the safe installation of those masonry heaters.
1.2 Values given in SI units are to be regarded as standard. Inch/pound units may be rounded (see IEEE/ASTM SI-10). All dimensions are nominal unless specifically stated otherwise. All clearances listed in this guide are actual dimensions.
1.3 This guide applies to the design and construction of masonry heaters built on-site with the components and materials specified herein. It does not apply to the construction/installation requirements for component systems that have been safety tested and listed. The requirements for listed masonry heater systems are specified in the manufacturer's installation instructions.
1.4 The design and construction of solid fuel burning masonry heaters shall comply with applicable building codes.
- Guide7 pagesEnglish language
SCOPE
1.1 This guide covers the design and construction of solid fuel burning masonry heaters. It provides dimensions for site constructed masonry heater components and clearances that have been derived by experience and found to be consistent with the safe installation of those masonry heaters.
1.2 Values given in SI units are to be regarded as standard. Inch/pound units may be rounded (see IEEE/ASTM SI-10). All dimensions are nominal unless specifically stated otherwise. All clearances listed in this guide are actual dimensions.
1.3 This guide applies to the design and construction of masonry heaters built on-site with the components and materials specified herein. It does not apply to the construction/installation requirements for component systems that have been safety tested and listed. The requirements for listed masonry heater systems are specified in the manufacturer's installation instructions.
1.4 The design and construction of solid fuel burning masonry heaters shall comply with applicable building codes.
- Guide7 pagesEnglish language
SCOPE
1.1 This specification covers performance requirements, test methods, and marking requirements for automatic feed, pellet fuel-burning room heaters that are intended to burn wood pellets or other suitable solid fuel. These room heaters shall be drafted by forced or natural means.
1.2 Exhaust venting systems and associated externally mounted draft inducers are not evaluated by this specification unless they are part of an engineered system provided as part of the room heater. Parts specifically evaluated and determined to be acceptable for use with pellet fuel-burning room heaters are required to be specified in the room heater manufacturer's instructions and are to be used in evaluating the room heater.
1.3 Pellet fuel-burning room heaters covered by this specification are intended for installation in accordance with the applicable requirements of NFPA 211 and in accordance with the applicable building and mechanical codes.
1.4 Pellet fuel-burning room heaters covered by this specification are acceptable for use in manufactured homes when installed in accordance with the Manufactured Home Construction and Safety Standards published by the Department of Housing and Urban Development (HUD). See 24 CFR 3280.
1.5 The terms "product" or "room heater," as used in this specification, refer to all pellet fuel-burning room heaters or any part thereof covered by the requirements of this specification, unless specifically noted otherwise.
1.6 No information provided in this specification is intended to prevent the use of other methods or devices, provided that sufficient technical data are submitted to the authority having jurisdiction to demonstrate that the proposed method or device is equivalent in quality, strength, fire endurance, effectiveness, durability, and safety to that prescribed in this specification.
1.7 The notes incorporated into this specification are not prescriptive requirements. They are given for clarification and informational purposes only.
1.8 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.9 The following safety hazards caveat pertains only to the test methods portion, Section 10, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Technical specification18 pagesEnglish language
Frequently Asked Questions
E06.54 is a Technical Committee within ASTM International. It is named "Solid Fuel Burning Appliances". This committee has published 37 standards.
E06.54 develops ASTM standards in the area of Information technology. Currently, there are 37 published standards from this technical committee.
ASTM is a standardization organization that develops and publishes standards to support industry, commerce, and regulatory requirements.
A Technical Committee (TC) in ASTM is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.