This document is a specification for vertical, cylindrical tank systems, built on site, above ground and of which either the primary liquid container or the liquid tight barrier is made of steel. The secondary liquid container, if applicable, can be of steel or of concrete or a combination of both. A primary liquid container made of pre-stressed concrete is excluded from the scope of this document.
This document provides general requirements and specifies principles and application rules for the structural design of the tank system during construction, testing, commissioning, operation (accidental included), and decommissioning. This document applies to all tank system components attached to and located within the liquid, vapour, purge gas, membrane or membrane tank outer containers of the tank system. It does not address the requirements for ancillary equipment such as pumps, pumpwells, valves, instrumentation, external staircases and walkways, roof mounted platforms, external pipe supports, etc. The requirements for those components are covered by the relevant European Standards, structurally designed in accordance with Eurocodes where appropriate, and meeting applicable safety regulations.
This document also does not address tank system operating procedures unless specified for determination of the relevant resistance and protection criteria for the tank systems. It specifies minimum performance requirements for the tank system, tank system foundation and protection systems. From a process piping standpoint, the scope of this document is limited to the following boundaries:
a)   the face of the first flange outside of the tank in bolted flanged connection;
b)   the first threaded joint outside of the tank in threaded connection;
c)   the first circumferential pipe welded joint outside of the tank in welding-end pipe connection, which does not have a flange.
This document is applicable to storage tank systems designed to store products, having an atmospheric boiling point below ambient temperature, in a dual phase, i.e. liquid and vapour. The equilibrium between liquid and vapour phases being maintained by cooling down the product to a temperature equal to, or just below, its atmospheric boiling point in combination with a slight overpressure in the storage tank system.
The maximum design pressure of the tank systems covered by this document is limited to 500 mbar. For higher pressures, reference can be made to EN 13445, Parts 1 to 5.
The operating range of the gases to be stored is between 0 °C and −196°C.
The tank systems covered by this document are used to store large volumes of hydrocarbon products, ammonia and other non-hydrocarbon gases with low temperature boiling points, generally called “Refrigerated Liquefied Gases” (RLGs). Typical products stored in the tank systems are: methane, ethane, propane, butane, ethylene, propylene, butadiene (this range includes the Liquefied Natural Gas (LNG’s) and Liquefied Petroleum Gas (LPG’s)), ammonia, nitrogen, oxygen and argon.
NOTE 1   Properties of the gases are given in Annex A.
The requirements of this document cannot cover all details of design and construction because of the variety of sizes and configurations that may be employed. Where complete requirements for a specific design are not provided, the intention is for the designer, subject to approval of the purchaser's authorized representative and of the regulatory body, to provide design and details that are as safe as those laid out in this document.
EN 14620 consists of multiple parts.  This document specifies general requirements for the tank system concept, selection and general design considerations.
In case of a conflict between general requirements of this document and the requirements in other parts of EN 14620 related to a specific liquefied gas, the product-specific requirements set forth in the other parts prevail.

  • Draft
    60 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies minimum requirements concerning material, design, construction and workmanship, manufacturing processes and testing of refillable transportable welded carbon steel gas cylinders of water capacities up to and including 150 l for compressed, liquefied and dissolved gases.
For acetylene service, additional requirements for the cylinder and basic requirements for the porous material are given in EN ISO 3807. For cylinder shells for acetylene service manufactured from high frequency induction (HFI) welded steel tubes by spinning of the end, the requirements are given in Annex A.
This document is primarily applicable to industrial gases other than LPG but can also be applied for LPG. However for dedicated LPG cylinders, see EN 1442.

  • Draft
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives a list of FTSC (fire potential, i.e. “oxidizing power and flammability”, toxicity, state of the gas, and corrosiveness) codes determined according to the relevant properties of gases and of some liquids that are transported under pressure.
It does not cover material compatibility with gases which is covered by the ISO 11114 series.

  • Draft
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives a list of FTSC (fire potential, i.e. “oxidizing power and flammability”, toxicity, state of the gas, and corrosiveness) codes determined according to the relevant properties of gases and of some liquids that are transported under pressure. It does not cover material compatibility with gases which is covered by the ISO 11114 series.

  • Standard
    43 pages
    English language
    sale 15% off
  • Standard
    46 pages
    French language
    sale 15% off
  • Standard
    4 pages
    English language
    sale 15% off
  • Standard
    4 pages
    French language
    sale 15% off

This document specifies design, type testing and marking requirements for:
a)       cylinder valves intended to be fitted to refillable transportable gas cylinders;
b)       main valves (excluding ball valves) for bundles of cylinders;
c)        cylinder valves or main valves with integrated pressure regulator (VIPR);
NOTE 1        This includes the following specific VIPR designs where:
1)  The pressure regulating system is acting as the primary valve operating mechanism (VIPR type B). This also includes designs where closure of the primary valve operating mechanism is obtained by closing the seat of the pressure regulating mechanism.
2)  The primary valve operating mechanism is located at the low-pressure side of the pressure regulating system (VIPR type C).
d)       valves for pressure drums and tubes;
which convey compressed, liquefied or dissolved gases.
NOTE 2        Where there is no risk of ambiguity, cylinder valves, main valves, VIPRs and valves for pressure drums and tubes are addressed with the collective term “valves” within this document.
This document does not apply to
—     valves for cryogenic equipment, portable fire extinguishers and liquefied petroleum gas (LPG);
—     quick-release cylinder valves (e.g. for fire-extinguishing, explosion protection and rescue applications) - requirements for quick-release cylinder valves are specified in ISO 17871 which contains normative references to this document;
—     self-closing cylinder valves and ball valves.
NOTE 3        Requirements for valves for cryogenic vessels are specified in ISO 21011 and at a regional level, e.g. in EN 1626. Requirements for LPG valves are specified in ISO 14245 or ISO 15995. Requirements for self-closing cylinder valves are specified in ISO 17879. Requirements for ball valves are specified in ISO 23826. Requirements for valves for portable fire extinguishers at a regional level are specified, for example, in the EN 3 series.
This document only covers the function of a valve as a closure. Other functions that are possibly integrated in the valve can be covered by other standards. Such standards do however not constitute requirements according to this document.
NOTE 4        Definition of and specific requirements for VIPRs in addition to those that are given in this document are specified in ISO 22435 for industrial applications or ISO 10524-3 for medical applications. Similarly, certain specific requirements for residual pressure valves (RPV) with or without a non-return function in addition to those that are given in this document are given in ISO 15996.
NOTE 5        Certain specific requirements for valves for breathing apparatus in addition to those that are given in this document are specified at a regional level, for example, in the EN 144 series. Certain specific requirements for quick-release valves for fixed fire-fighting systems in addition to those that are given in this document are specified in ISO 16003 and at a regional level, for example, in EN 12094–4.
NOTE 6        Requirements for manufacturing tests and examinations of valves covered by this document are given in ISO 14246.

  • Draft
    64 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies design, type test methods, marking and instruction requirements for cylinder valves with integrated pressure regulators (VIPRs) intended to be fitted to gas cylinders, pressure drums or tubes or used as a main valve for bundles of cylinders that convey compressed, liquefied or dissolved gases.
These are requirements for VIPRs that are in addition to those given in the relevant closure standard, for example, in ISO 10297 for cylinder valves, in ISO 17871 for quick-release cylinder valves, in ISO 17879 for self-closing cylinder valves or in ISO 23826 for ball valves. For ISO 17871, these requirements are only applicable to quick-release cylinder valves types B, C, D and E.
NOTE 1        If the pressure regulating system of a VIPR is acting as the primary valve operating mechanism, it is covered by the relevant closure standard, e.g. ISO 10297, ISO 17871, ISO 17879 and ISO 23826. This also includes designs where closure of the primary valve operating mechanism of a VIPR is obtained by closing the seat of the pressure regulating system.
NOTE 2        If the primary valve operating mechanism of a VIPR is located at the low-pressure side of the pressure regulating system, it is covered by the relevant closure standard, e.g. ISO 10297, ISO 17871, ISO 17879 and ISO 23826.
NOTE 3        The term “pressure receptacle” is used within this document to cover instances where no differentiation is necessary between gas cylinders, bundles of cylinders, pressure drums and tubes.
This document does not apply to VIPRs for
a)       medical applications (see ISO 10524-3);
b)       liquefied petroleum gas (LPG);
c)        cryogenic applications.
NOTE 4        Additional requirements for a VIPR with a residual pressure device (RPD) are specified in ISO 15996.
NOTE 5        Additional requirements for pressure relief valves can exist in international/regional regulations/ standards.

  • Draft
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies design, type testing and marking requirements for: a) cylinder valves intended to be fitted to refillable transportable gas cylinders; b) main valves (excluding ball valves) for bundles of cylinders; c) cylinder valves or main valves with integrated pressure regulator (VIPR); NOTE 1 This includes the following specific VIPR designs where: 1) The pressure regulating system is acting as the primary valve operating mechanism (VIPR type B). This also includes designs where closure of the primary valve operating mechanism is obtained by closing the seat of the pressure regulating mechanism. 2) The primary valve operating mechanism is located at the low-pressure side of the pressure regulating system (VIPR type C). d) valves for pressure drums and tubes; which convey compressed, liquefied or dissolved gases. NOTE 2 Where there is no risk of ambiguity, cylinder valves, main valves, VIPRs and valves for pressure drums and tubes are addressed with the collective term “valves” within this document. This document does not apply to — valves for cryogenic equipment, portable fire extinguishers and liquefied petroleum gas (LPG); — quick-release cylinder valves (e.g. for fire-extinguishing, explosion protection and rescue applications) - requirements for quick-release cylinder valves are specified in ISO 17871 which contains normative references to this document; — self-closing cylinder valves and ball valves. NOTE 3 Requirements for valves for cryogenic vessels are specified in ISO 21011 and at a regional level, e.g. in EN 1626. Requirements for LPG valves are specified in ISO 14245 or ISO 15995. Requirements for self-closing cylinder valves are specified in ISO 17879. Requirements for ball valves are specified in ISO 23826. Requirements for valves for portable fire extinguishers at a regional level are specified, for example, in the EN 3 series. This document only covers the function of a valve as a closure. Other functions that are possibly integrated in the valve can be covered by other standards. Such standards do however not constitute requirements according to this document. NOTE 4 Definition of and specific requirements for VIPRs in addition to those that are given in this document are specified in ISO 22435 for industrial applications or ISO 10524-3 for medical applications. Similarly, certain specific requirements for residual pressure valves (RPV) with or without a non-return function in addition to those that are given in this document are given in ISO 15996. NOTE 5 Certain specific requirements for valves for breathing apparatus in addition to those that are given in this document are specified at a regional level, for example, in the EN 144 series. Certain specific requirements for quick-release valves for fixed fire-fighting systems in addition to those that are given in this document are specified in ISO 16003 and at a regional level, for example, in EN 12094–4. NOTE 6 Requirements for manufacturing tests and examinations of valves covered by this document are given in ISO 14246.

  • Standard
    59 pages
    English language
    sale 15% off
  • Standard
    62 pages
    French language
    sale 15% off

This document specifies design, type test methods, marking and instruction requirements for cylinder valves with integrated pressure regulators (VIPRs) intended to be fitted to gas cylinders, pressure drums or tubes or used as a main valve for bundles of cylinders that convey compressed, liquefied or dissolved gases. These are requirements for VIPRs that are in addition to those given in the relevant closure standard, for example, in ISO 10297 for cylinder valves, in ISO 17871 for quick-release cylinder valves, in ISO 17879 for self-closing cylinder valves or in ISO 23826 for ball valves. For ISO 17871, these requirements are only applicable to quick-release cylinder valves types B, C, D and E. NOTE 1 If the pressure regulating system of a VIPR is acting as the primary valve operating mechanism, it is covered by the relevant closure standard, e.g. ISO 10297, ISO 17871, ISO 17879 and ISO 23826. This also includes designs where closure of the primary valve operating mechanism of a VIPR is obtained by closing the seat of the pressure regulating system. NOTE 2 If the primary valve operating mechanism of a VIPR is located at the low-pressure side of the pressure regulating system, it is covered by the relevant closure standard, e.g. ISO 10297, ISO 17871, ISO 17879 and ISO 23826. NOTE 3 The term “pressure receptacle” is used within this document to cover instances where no differentiation is necessary between gas cylinders, bundles of cylinders, pressure drums and tubes. This document does not apply to VIPRs for a) medical applications (see ISO 10524-3); b) liquefied petroleum gas (LPG); c) cryogenic applications. NOTE 4 Additional requirements for a VIPR with a residual pressure device (RPD) are specified in ISO 15996. NOTE 5 Additional requirements for pressure relief valves can exist in international/regional regulations/ standards.

  • Standard
    29 pages
    English language
    sale 15% off
  • Standard
    32 pages
    French language
    sale 15% off

This document specifies the minimum requirements for the design and construction of metallic
pressure tanks for the transport of dangerous goods by road and rail and sea. It is not
applicable to gravity-discharge tanks according to RID/ADR 6.8.2.1.14 (a).
This document includes requirements for openings, closures and structural equipment; it does not cover requirements of service equipment. For tanks for the transport of cryogenic liquids, EN 13530-1 and EN 13530-2 apply.
Design and construction of pressure tanks according to the Scope of this document are primarily subject to the requirements of RID/ADR, Subsections 6.8.2.1, 6.8.3.1 and 6.8.5, as relevant. In addition, the relevant requirements of RID/ADR, Table A, columns 12 and 13, to Chapters 3.2, 4.3 and Subsection 6.8.2.4 apply. For the structural equipment RID/ADR, Subsections 6.8.2.2 and 6.8.3.2 apply, as relevant. The definitions of RID/ADR, Subsection 1.2.1, are referred to. For portable tanks see also RID/ADR, Chapter 4.2 and Sections 6.7.2 and 6.7.3. In addition, the relevant requirements of RID/ADR, Table A, Columns 10 and 11 to Chapters 3.2, 4.2, and Sections 6.7.2 and 6.7.3 apply. The paragraph numbers above relate to the 2017 issue of RID/ADR which are subject to regular revisions. This can lead to temporary non-compliances with EN 14025.
This document is applicable to liquefied gases including LPG; however for a dedicated LPG standard see EN 12493.
If not otherwise specified, provisions which take up the whole width of the page apply to all kind of tanks. Provisions contained in a single column apply only to:
-tanks according to RID/ADR Chapter 6.8 (left-hand column);
-portable tanks according to RID/ADR Chapter 6.7 (right-hand column).

  • Standard
    64 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the minimum requirements for the design and construction of metallic
pressure tanks for the transport of dangerous goods by road and rail and sea. It is not
applicable to gravity-discharge tanks according to RID/ADR 6.8.2.1.14 (a).
This document includes requirements for openings, closures and structural equipment; it does not cover requirements of service equipment. For tanks for the transport of cryogenic liquids, EN 13530-1 and EN 13530-2 apply.
Design and construction of pressure tanks according to the Scope of this document are primarily subject to the requirements of RID/ADR, Subsections 6.8.2.1, 6.8.3.1 and 6.8.5, as relevant. In addition, the relevant requirements of RID/ADR, Table A, columns 12 and 13, to Chapters 3.2, 4.3 and Subsection 6.8.2.4 apply. For the structural equipment RID/ADR, Subsections 6.8.2.2 and 6.8.3.2 apply, as relevant. The definitions of RID/ADR, Subsection 1.2.1, are referred to. For portable tanks see also RID/ADR, Chapter 4.2 and Sections 6.7.2 and 6.7.3. In addition, the relevant requirements of RID/ADR, Table A, Columns 10 and 11 to Chapters 3.2, 4.2, and Sections 6.7.2 and 6.7.3 apply. The paragraph numbers above relate to the 2017 issue of RID/ADR which are subject to regular revisions. This can lead to temporary non-compliances with EN 14025.
This document is applicable to liquefied gases including LPG; however for a dedicated LPG standard see EN 12493.
If not otherwise specified, provisions which take up the whole width of the page apply to all kind of tanks. Provisions contained in a single column apply only to:
-tanks according to RID/ADR Chapter 6.8 (left-hand column);
-portable tanks according to RID/ADR Chapter 6.7 (right-hand column).

  • Standard
    64 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for steel products used for unfired pressure vessels.
For some metallic materials other than steel, such as spheroidal graphite cast iron, aluminium, nickel, copper, titanium, requirements are or will be formulated in separate parts of this document.
For metallic materials which are not covered by a harmonized material standard and are not likely to be in near future, specific rules are given in this part or the above cited parts of this document.

  • Standard
    90 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for the manufacture of unfired pressure vessels and their parts, made of steels, including their connections to non-pressure parts. It specifies requirements for material traceability, manufacturing tolerances, welding requirements, requirements for permanent joints other than welding, production tests, forming requirements, heat treatment, repairs and finishing operations.

  • Standard
    74 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for periodic inspection and testing to verify the integrity for further service of hoop-wrapped and fully-wrapped composite transportable gas cylinders and tubes, with aluminium-alloy, steel or non-metallic liners or of linerless construction (Types 2, 3, 4, and 5), intended for compressed, liquefied or dissolved gases under pressure, of water capacity from 0,5 l up to 3 000 l.
This document addresses the periodic inspection and testing of composite cylinders and tubes constructed according to ISO 11119-1, ISO 11119-2, ISO 11119-3, ISO 11119-4 or ISO 11515. It can be applied to other composite cylinders and tubes designed to comparable standards when authorized by the competent authority. As far as practicable, this document can also be applied to cylinders of less than 0,5 l water capacity when authorized by the manufacturer.
NOTE    Unless noted by exception, the use of the word “cylinder” in this document refers to both cylinders and tubes.

  • Standard
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the minimum requirements concerning material selection, design, construction and workmanship, procedure, and test at manufacture of refillable welded-steel gas cylinders of water capacities from 0,5 l up to and including 150 l and drums of water capacities of 150 l to 500 l of a test pressure not greater than 60 bar[1], exposed to extreme worldwide temperatures (−50 °C to +65 °C) used for compressed, liquefied or dissolved gases. NOTE Unless specified in the text, for the purpose of this document, the word “cylinder” includes “pressure drums”. This document is primarily intended to be used for industrial gases other than liquefied petroleum gas (LPG), and is also applicable to LPG. [1] 1 bar = 0,1 MPa = 105 Pa; 1 MPa = 1 N/mm2.

  • Standard
    32 pages
    English language
    sale 15% off

This document specifies the requirements for periodic inspection and testing to verify the integrity for further service of hoop-wrapped and fully-wrapped composite transportable gas cylinders and tubes, with aluminium-alloy, steel or non-metallic liners or of linerless construction (Types 2, 3, 4, and 5), intended for compressed, liquefied or dissolved gases under pressure, of water capacity from 0,5 l up to 3 000 l.
This document addresses the periodic inspection and testing of composite cylinders and tubes constructed according to ISO 11119-1, ISO 11119-2, ISO 11119-3, ISO 11119-4 or ISO 11515. It can be applied to other composite cylinders and tubes designed to comparable standards when authorized by the competent authority. As far as practicable, this document can also be applied to cylinders of less than 0,5 l water capacity when authorized by the manufacturer.
NOTE    Unless noted by exception, the use of the word “cylinder” in this document refers to both cylinders and tubes.

  • Standard
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to pin-index yoke-type valve connections for medical gas cylinders, with a working pressure up to a maximum of 200 bar or test pressure up to a maximum of 300 bar, or both.
NOTE 1    This type of connection is primarily used for small cylinders (5 l or below).
NOTE 2    In this document the unit bar is used, due to its universal use in the field of technical gases. It should, however, be noted that bar is not an SI unit, and that the corresponding SI unit for pressure is Pa (1 bar = 105 Pa = 105 N/m2).
This document specifies:
—    basic dimensions;
—    requirements for alternative designs of the yoke-type valve connections;
—    dimensions and positions for the holes and pins for the outlet connections.
It also specifies the dimensions and positions for the holes and pins for the outlet connections for gases and gas mixtures.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for foot valves for use on transportable tanks with a minimum working pressure greater than 50 kPa for the transport of dangerous goods by road and rail.
It is applicable to metallic equipment for use on tanks with gravity and/or pressure bottom loading and discharge for liquid chemicals and liquefied gases. It includes carbon dioxide while excluding refrigerated liquefied gases.
NOTE The standard is also applicable to liquefied gases including LPG, however, for a dedicated LPG standard see EN 13175 [3].

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies filling, discharge and emergency procedures for road tankers equipped in accordance with EN 12252 used for the transportation of liquefied petroleum gas (LPG).
This document does not apply to "batteries of receptacles".

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies discharge, handling operations and emergency procedures for rail tankers used for the transport of liquefied petroleum gas (LPG).
This document applies to operations where LPG is off-loaded from rail tankers into LPG fixed storage facilities and road tankers.
This document includes limitations to limit the discharge of rail tankers into other rail tankers.
This document does not apply to "tank containers" and "batteries of receptacles".

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies minimum requirements for the inspection and testing of the LPG road tanker, which includes its pressure vessel, accessories and vehicle LPG equipment.
This document does not specify requirements for the initial inspection (after manufacture) of a pressure vessel, see EN 12493, or for service equipment on the road tanker, see EN 12252.
This document does not apply to compartmented road tankers.
NOTE 1   There is no upper size limit for the pressure vessel as this will be determined by the gross vehicle weight limitation.
NOTE 2   For inspection and testing requirements of equipment other than the pressure vessel, accessories and vehicle LPG equipment, see applicable regulations.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for product discharge and air inlet valves for use on transportable tanks with a minimum working pressure greater than 50 kPa for the transport of dangerous goods by road and rail.
NOTE 1 The term 'valve' includes ball valves as well as butterfly valves and similar closure devices.
It is applicable to metallic equipment for use on tanks with gravity and/or pressure filling and discharge for liquid chemicals and liquefied gases. It includes carbon dioxide while excluding refrigerated liquefied gases.
NOTE 2 The standard is also applicable to liquefied gases including LPG, however, for a dedicated LPG standard see EN 13175 [3].

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for the manufacture of unfired pressure vessels and their parts, made of steels, including their connections to non-pressure parts. It specifies requirements for material traceability, manufacturing tolerances, welding requirements, requirements for permanent joints other than welding, production tests, forming requirements, heat treatment, repairs and finishing operations.

  • Standard
    74 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for steel products used for unfired pressure vessels.
For some metallic materials other than steel, such as spheroidal graphite cast iron, aluminium, nickel, copper, titanium, requirements are or will be formulated in separate parts of this document.
For metallic materials which are not covered by a harmonized material standard and are not likely to be in near future, specific rules are given in this part or the above cited parts of this document.

  • Standard
    90 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for valves useable on tanks with a minimum working pressure greater than 50 kPa for the transport of dangerous goods by road and rail for the following functions:
Tanks for transport of liquid products:
- secondary closure of bottom discharge lines;
- primary closure on top of the tank (liquid, air, other connections);
- aeration valve on top of the tank;
- and other valves as specified in Annex F of EN 14564:2019 according to the scope of this document.
Tanks for gases:
- secondary closure of bottom discharge lines;
- secondary closure on top of the tank for poisonous gases: liquid phase and gas phase;
- and other valves as specified in Annex F of EN 14564:2019.
This includes the following types of closures:
- valves (e.g. spindle operated valves, plug and ball valves, butterfly valves and gate valves);
- dry disconnect couplings.
Primary closures of the gas phase at the foot of a tank for liquefied gas are covered by the requirements of foot valves in EN 14433.
NOTE The standard is also applicable to liquefied gases including LPG, however, for a dedicated LPG standard see EN 13175 [3]

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for foot valves for use on tanks with a minimum working pressure greater than 50 kPa for the transport of dangerous goods by road and rail.
It is applicable to metallic equipment on tanks for the following functions for internal stop valves:
- primary closure of gravity discharge lines (liquid substances);
- primary closure of bottom discharge lines (liquid gases: liquid phase and gas phase);
- primary closure of top discharge (poisonous liquefied gases: liquid phase and gas phase);
- and other internal valves as specified in Annex F of EN 14564:2019 according to the scope of this document.
NOTE 1 The document is also applicable to liquefied gases including LPG; however, for a dedicated LPG standard see EN 13175 [3].
NOTE 2 Valves according to this document can be used as primary closure in case of top discharge of liquids and other products.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for periodic inspection and testing to verify the integrity for further service of hoop-wrapped and fully-wrapped composite transportable gas cylinders and tubes, with aluminium-alloy, steel or non-metallic liners or of linerless construction (Types 2, 3, 4, and 5), intended for compressed, liquefied or dissolved gases under pressure, of water capacity from 0,5 l up to 3 000 l. This document addresses the periodic inspection and testing of composite cylinders and tubes constructed according to ISO 11119-1, ISO 11119-2, ISO 11119-3, ISO 11119-4 or ISO 11515. It can be applied to other composite cylinders and tubes designed to comparable standards when authorized by the competent authority. As far as practicable, this document can also be applied to cylinders of less than 0,5 l water capacity when authorized by the manufacturer. NOTE Unless noted by exception, the use of the word “cylinder” in this document refers to both cylinders and tubes.

  • Standard
    39 pages
    English language
    sale 15% off
  • Standard
    41 pages
    French language
    sale 15% off

This document lists gas cylinders valve outlets in use. This document provides details of thread types and sizes. NOTE Complete descriptions of particular valve outlets are given in national standards.

  • Technical report
    6 pages
    English language
    sale 15% off

This document specifies procedures for filling, discharge and handling operations as well as emergency procedures for rail tankers used for the transport of liquefied petroleum gas (LPG).
This document does not apply to “tank containers” and “batteries of receptacles”.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the minimum requirements for the materials, design, construction and workmanship, manufacturing processes, examinations and testing at time of manufacture for refillable, seamless, stainless steel gas cylinders with water capacities up to and including 150 l.
It is applicable to cylinders for compressed, liquefied and dissolved gases with a maximum actual tensile strength, Rma, of less than 1 100 MPa.
NOTE   If so desired, cylinders of water capacity between 150 l and 450 l can be manufactured to be in full conformance to this document.

  • Standard
    63 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies minimum requirements for material, design, construction and workmanship, testing and examination during the manufacture of transportable refillable welded aluminium liquefied petroleum gas (LPG) cylinders, having a water capacity from 0,5 litres up to and including 150 litres, exposed to ambient temperature.

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for the design, material, manufacturing and testing of cast iron pressure vessels and pressure vessel parts made from materials for which details are specified from the following material standards for specific grades which meet the criterion of an elongation after fracture less than or equal to 15 %:
-   EN 1561:2011, Founding - Grey cast irons;
-   EN 1563:2018, Founding - Spheroidal graphite cast irons;
-   EN 13835:2012, Founding - Austenitic cast irons.
The application of this document is limited to pressure equipment and pressure parts containing a fluid of group 2 (non-hazardous fluid) according to the European legislation for pressure equipment.

  • Standard
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the following, in order to determine the corrosiveness of gases and gas mixtures so that a suitable outlet connection can be assigned to each of them:
—    for pure gases and some liquids, a complete list indicating their corrosiveness;
—    for gas mixtures, a calculation method, in the absence of experimental data, relating to the corrosiveness of each of their components.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies minimum requirements for material, design, construction and workmanship, testing and examination during the manufacture of transportable refillable welded aluminium liquefied petroleum gas (LPG) cylinders, having a water capacity from 0,5 l up to and including 150 l, exposed to ambient temperature.

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the minimum requirements for the materials, design, construction and workmanship, manufacturing processes, examinations and testing at time of manufacture for refillable, seamless, stainless steel gas cylinders with water capacities up to and including 150 l.
It is applicable to cylinders for compressed, liquefied and dissolved gases with a maximum actual tensile strength, Rma, of less than 1 100 MPa.
NOTE         If so desired, cylinders of water capacity between 150 l and 450 l can be manufactured to be in full conformance to this document.

  • Standard
    63 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies minimum requirements for the materials, design, construction, prototype testing and routine manufacturing inspections of fully wrapped composite gas cylinders for compressed, liquefied and dissolved gases.
NOTE 1   For the purposes of this document, the word “cylinder” includes tubes (seamless transportable pressure receptacles of a water capacity exceeding 150 l and of not more than 3 000 l).
This document is applicable to cylinders that comprise a liner of metallic material (welded or seamless) or non-metallic material (or a mixture thereof), reinforced by a wound composite consisting of fibres of glass, carbon or aramid (or a mixture thereof) embedded in a matrix.
This document is also applicable to composite cylinders without liners.
This document is not applicable to gas cylinders which are partially covered with fibres and commonly called “hoop wrapped” cylinders. For hoop wrapped composite cylinders, see EN 12257.
NOTE 2   This document does not address the design, fitting and performance of removable protective sleeves. Where these are fitted, they are considered separately.
This document is primarily for compressed, liquefied and dissolved gases other than LPG.
NOTE 3   For dedicated LPG cylinders, see EN 14427.

  • Standard
    65 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for the design and construction of metallic gravity-discharge tanks intended for the carriage of substances having a vapour pressure not exceeding 110 kPa (1,1 bar) (absolute pressure) at 50 °C.
NOTE 1   Gravity-discharge tanks have no maximum working pressure. However, during operation, pressure in the shell may occur, for example due to flow restrictions in vapour recovery systems or opening pressures of breather devices. It is important that these operating pressures do not exceed the test pressure of the tank or 0,5 bar, whichever is the highest.
This document specifies requirements for openings, closures, pipework, mountings for service equipment and structural equipment.
NOTE 2   This document does not specify requirements for items of service equipment other than pipes passing through the shell.
This document is applicable to aircraft refuelers that are used on public roads. It is also applicable to inter-modal tanks (e.g. tank containers and tank swap bodies) for the transport of dangerous goods by road and rail.
NOTE 3   This document is not applicable to fixed rail tank wagons.

  • Standard
    96 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for the design and use of vitreous enamel coated bolted
cylindrical steel tanks for the storage or treatment of water or municipal or industrial effluents and
sludges.
It is applicable to the design of the tank and any associated roof and gives guidance on the requirements
for the design of the foundation.
It is applicable where:
a) the tank is cylindrical and is mounted on a load-bearing base substantially at or above ground level;
b) the product of the tank diameter in metres and the wall height in metres lies within the range
5 to 500;
c) the tank diameter does not exceed 100 m and the total wall height does not exceed 50 m;
d) the stored material has the characteristics of a liquid, exerting a negligible frictional force on the
tank wall; the stored material can be undergoing treatment as part of a municipal or industrial
effluent treatment process;
e) the internal pressure in the headspace above the liquid does not exceed 50 kPa and the internal
partial vacuum above the liquid does not exceed 10 kPa;
f) the walls of the tank are vertical;
g) the floor of the tank is substantially flat at its intersection with the wall; the floor of the tank can
have a rise or fall built in to allow complete emptying of the tank contents, the slope of which does
not exceed 1:100;
h) there is negligible inertial and impact load due to tank filling;
i) the minimum thickness of the tank shell is 1,5 mm;
j) the material used for the manufacture of the steel sheets is carbon steel (tanks constructed of
sheets made from aluminium or stainless steel are outside the scope of this document);
k) the temperature of the tank wall during operation is within the range −50 °C to +100 °C under all
operating conditions.
This document also gives details of procedures to be followed during installation on site and for
inspection and maintenance of the installed tank.
It does not apply to chemical-reaction vessels.
It does not cover resistance to fire.