D19 - Water
The study of water, the promotion of knowledge thereof, and the standardization of terminology methods for: * Sampling and analysis of water, waterborne materials, and wastes, water- formed deposits and fluvial sediments, * Surface-water hydraulics and hydrologic measurements, * The determination of the performance of materials or products used to modify water characteristics, and * The determination of the corrosivity or deposit forming properties of water. The term "water" includes, but is not limited to, surface waters (rivers, lakes, artificial impoundments, runoff, etc.), groundwaters and springwaters, wastewaters (mine drainage, landfill leachate, brines, waters resulting from atmospheric precipitation and condensation (with the exception of acid deposition), process waters, potable waters, glacial melt waters, steam, water for subsurface injection and water discharges including waterborne materials and water-formed deposits. The work of the Committee will be coordinated with other ASTM Committees and other societies and organizations having mutual interests.
Water
The study of water, the promotion of knowledge thereof, and the standardization of terminology methods for: * Sampling and analysis of water, waterborne materials, and wastes, water- formed deposits and fluvial sediments, * Surface-water hydraulics and hydrologic measurements, * The determination of the performance of materials or products used to modify water characteristics, and * The determination of the corrosivity or deposit forming properties of water. The term "water" includes, but is not limited to, surface waters (rivers, lakes, artificial impoundments, runoff, etc.), groundwaters and springwaters, wastewaters (mine drainage, landfill leachate, brines, waters resulting from atmospheric precipitation and condensation (with the exception of acid deposition), process waters, potable waters, glacial melt waters, steam, water for subsurface injection and water discharges including waterborne materials and water-formed deposits. The work of the Committee will be coordinated with other ASTM Committees and other societies and organizations having mutual interests.
General Information
SIGNIFICANCE AND USE
5.1 Purgeable organic compounds, including organohalides, have been identified as contaminants in raw and drinking water. These contaminants may be harmful to the environment and man. Dynamic headspace sampling is a generally applicable method for concentrating these components prior to gas chromatographic analysis (1-5).3 This test method can be used to quantitatively determine purgeable organic compounds in raw source water, drinking water, and treated effluent water.
SCOPE
1.1 This test method covers the determination of most purgeable organic compounds that boil below 200 °C and are less than 2 % soluble in water. It covers the low μg/L to low mg/L concentration range (see Section 15 and Appendix X1).
1.2 This test method was developed for the analysis of drinking water. It is also applicable to many environmental and waste waters when validation, consisting of recovering known concentrations of compounds of interest added to representative matrices, is included.
1.3 Volatile organic compounds in water at concentrations above 1000 μg/L may be determined by direct aqueous injection in accordance with Practice D2908.
1.4 It is the user's responsibility to assure the validity of the test method for untested matrices.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in 8.5.5.1.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard8 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method is useful for the analysis of drinking water and groundwaters. Other waters may be analyzed by this test method, see 1.2.
5.2 EDB and DBCP have been widely used as soil fumigants. EDB is also used as a lead scavenger in leaded gasolines. These compounds are very water soluble and are often found in groundwater and drinking water. Since they are highly toxic and are suspected carcinogens, there is concern about the potential health impact of even extremely low concentrations in potable water.
SCOPE
1.1 This test method covers the determination of 1,2-dibromoethane (commonly referred to as ethylene dibromide or EDB) and 1,2-dibromo-3-chloropropane (commonly referred to as DBCP) in water at a minimum detection level of 0.010 μg/L by liquid-liquid extraction combined with gas-liquid chromatography. This test method is applicable to the analysis of drinking waters and groundwaters. It is not recommended for wastewaters, due to the potential for interferences from high concentrations of other extractable organics. Similar information can be found in EPA Method 504.
1.2 This test method was used successfully with reagent water and groundwater. It is the user's responsibility to ensure the validity of this test method for waters of untested matrices.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Sections 6 and 9.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard7 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The extensive and widespread use of organochlorine pesticides and PCBs has resulted in their presence in all parts of the environment. These compounds are persistent and may have adverse effects on the environment. Thus, there is a need to identify and quantitate these compounds in water samples.
SCOPE
1.1 This test method (1-3)2 is applicable to the determination of the following analytes in finished drinking water, drinking water during intermediate stages of treatment, and the raw source water:
Analyte
Chemical Abstract Service
Registry Number A
Alachlor
5972-60-8
Aldrin
309-00-2
Chlordane
57-74-9
Dieldrin
60-57-1
Endrin
72-20-8
Heptachlor
76-44-8
Heptachlor Epoxide
1024-57-3
Hexachlorobenzene
118-74-1
Lindane
58-89-9
Methoxychlor
72-43-5
Toxaphene
8001-35-2
Aroclor B 1016
12674-11-2
Aroclor B 1221
11104-28-2
Aroclor B 1232
11141-16-5
Aroclor B 1242
53469-21-9
Aroclor B 1248
12672-29-6
Aroclor B 1254
11097-69-1
Aroclor B 1260
11096-82-5
1.2 Detection limits for most test method analytes are less than 1 μg/L. Actual detection limits are highly dependent on the characteristics of the sample matrix and the gas chromatography system. Table 1 contains the applicable concentration range for the precision and bias statements. Only Aroclor 1016 and 1254 were included in the interlaboratory test used to derive the precision and bias statements. Data for other PCB products are likely to be similar.
1.3 Chlordane, toxaphene, and Aroclor products (polychlorinated biphenyls) are multicomponent materials. Precision and bias statements reflect recovery of these materials dosed into water samples. The precision and bias statements may not apply to environmentally altered materials or to samples containing complex mixtures of polychlorinated biphenyls (PCBs) and organochlorine pesticides.
1.4 For compounds other than those listed in 1.1 or for other sample sources, the analyst must demonstrate the applicability of this test method by collecting precision and bias data on spiked samples (groundwater, tap water) (4) and provide qualitative confirmation of results by gas chromatography/mass spectrometry (GC/MS) (5) or by GC analysis using dissimilar columns.
1.5 This test method is restricted to use by or under the supervision of analysts experienced in the use of GC and in the interpretation of gas chromatograms. Each analyst must demonstrate the ability to generate acceptable results using the procedure described in Section 13.
1.6 Analytes that are not separated chromatographically, (analytes that have very similar retention times) cannot be individually identified and measured in the same calibration mixture or water sample unless an alternative technique for identification and quantitation exists (see 13.4).
1.7 When this test method is used to analyze unfamiliar samples for any or all of the analytes listed in 1.1, analyte identifications and concentrations should be confirmed by at least one additional technique.
1.8 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 9.
1.10 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for th...
- Standard12 pagesEnglish language
SIGNIFICANCE AND USE
4.1 Identification of the source of a spilled oil is established by comparison with known oils selected because of their possible relationship to the spill, that is, potential sources. Generally, the suspected source oils are from pipelines, tanks, etc., and therefore pose little problems in sampling compared to the spilled oil. This practice addresses the sampling of spilled oils in particular, but could be applied to appropriate source situations, for example, a ship's bilge.
SCOPE
1.1 These practices describe the procedures to be used in collecting samples of waterborne oils (see Practice D3415), oil found on adjoining shorelines, or oil-soaked debris, for comparison of oils by spectroscopic and chromatographic techniques, and for elemental analyses.
1.2 Two practices are described. Practice A involves “grab sampling” macro oil samples. Practice B can be used to sample most types of waterborne oils and is particularly applicable in sampling thin oil films or slicks. Practice selection will be dictated by the physical characteristics and the location of the spilled oil. These two practices are:
Sections
Practice A (for grab sampling thick layers of oil, viscous oils or oil soaked debris, oil globules, tar balls, or stranded oil)
9 to 13
Practice B (for TFE–fluorocarbon polymer strip samplers)
14 to 17
1.3 Each of the two practices is designed to collect oil samples with a minimum of water, thereby reducing the possibility of chemical, physical, or biological alteration by prolonged contact with water between the time of collection and analysis.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazards statements, see Section 7.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test provides an easy and reliable method for the detection of enterococci in water within 24 h. For recreational water (fresh and marine) testing is performed to insure areas are safe for swimming. Enterolert also can be used for testing bottled water, wastewater, ground water, and drinking water.
SCOPE
1.1 This test method covers a simple procedure for the detection of enterococci in water and wastewater. It is based on IDEXX’s patented Defined Substrate Technology (DST).2 This product, Enterolert, utilizes a nutrient indicator that fluoresces when metabolized. It can detect these bacteria at one most probable number (MPN)/100 mL within 24 h. The presence of this microorganism in water is an indication of fecal contamination and the possible presence of enteric pathogens.
1.2 This test method can be used successfully with drinking water, source water, recreational (fresh and marine) water, wastewater, and bottled water. It is the user’s responsibility to ensure the validity of this test method for waters of untested matrices.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard7 pagesEnglish language
- Standard7 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method is useful for measuring recreational water quality and chlorinated wastewaters, although it can be used for any water suspected of contamination by fecal wastes of warm-blooded animals. The significance of finding E. coli in recreational water samples, especially samples obtained from fresh recreational waters, is that there is a risk of gastrointestinal illness, directly related to the E. coli density, associated with swimming.5
5.2 Since small or large volumes of water or dilutions thereof can be analyzed by the MF technique, a wider range of levels of E. coli in water can be detected and enumerated than with other methods.
SCOPE
1.1 This test method describes a membrane filter (MF) procedure for the detection and enumeration of Escherichia coli, a bacterium found exclusively in the feces of humans and other warm-blooded animals. The presence of these microorganisms in water is an indication of fecal pollution and the possible presence of enteric pathogens. These bacteria are found in water and wastewater in a wide range of densities. The detection limit of this procedure is one colony forming unit (CFU) per volume filtered.
1.2 This test method has been used successfully with temperate fresh and marine ambient waters, and wastewaters. It is the user’s responsibility to ensure the validity of this test method for waters of other types.
1.3 The values stated in SI units are to be regarded as standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 9.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard6 pagesEnglish language
- Standard6 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The incidental conversion of organic material to trihalomethanes and other volatile organohalides during chlorination of water is a possible health hazard and is the object of much research. This test method can be used as a rapid, simple means for determining many volatile organohalides in raw and processed water.
SCOPE
1.1 This test method covers the analysis of drinking water. It is also applicable to many environmental and waste waters when adequate validation is included.
1.2 This test method covers the determination of halomethanes, haloethanes, and some related extractable organohalides amenable to gas chromatographic measurement. The applicable concentration range for trihalomethanes is from 1 μg/L to 200 μg/L. Detection limits depend on the compound, matrix, and on the characteristics of the gas chromatographic system.
1.3 For compounds not specifically included in the precision and bias section the analyst should validate the test method by collecting precision and bias data on actual samples.
1.4 Confirmation of component identities is obtained by observing retention times using gas chromatographic columns of different polarities. When concentrations are sufficiently high (>50 μg/L) confirmation with halogen specific detectors or gas chromatography/mass spectrometry (GC/MS) may be used. Confirmation of purgeable compounds at levels down to 1 μg/L can be obtained using Test Method D3871 with GC/MS detection.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 8.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
4.1 Oil from one crude oil field is readily distinguishable from another, and differences in the makeup of oils from the same crude oil field can often be observed as well. Refined oils are fractions from crude oil stocks, usually derived from distillation processes. Two refined oils of the same type differ because of dissimilarities in the characteristics of their crude oil feed stocks as well as variations in refinery processes and any subsequent contact with other oils mixed in during transfer operations from residues in tanks, ships, pipes, hoses, and so forth. Thus, all petroleum oils, to some extent, have chemical compositions different from each other.
4.2 Identification of a recovered oil is determined by comparison with known oils selected because of their possible relationship to the particular recovered oil, for example, suspected sources. Thus, samples of such known oils must be collected and submitted along with the unknown for analysis. Identification of the source of an unknown oil by itself cannot be made without comparison to a known oil. The principles of oil spill identification are discussed in Ref (1).4
4.3 Many similarities (within uncertainties of sampling, analysis and weathering) will be needed to establish the identity beyond a reasonable doubt. The analyses described will distinguish many, but not all samples. Examples of weathering of various classes of oils are included in Ref (2).
4.4 This practice is a guide to the use of ASTM test methods for the analysis of oil samples for oil spill identification purposes. The evaluation of results from analytical methods and preparation of an Oil Spill Identification Report are discussed in this practice. Other analytical methods are described in Ref (3).
4.5 A quality assurance program for oil spill identification is specified.
SCOPE
1.1 This practice covers the broad concepts of sampling and analyzing waterborne oils for identification and comparison with suspected source oils. Detailed procedures are referenced in this practice. A general approach is given to aid the investigator in planning a program to solve the problem of chemical characterization and to determine the source of a waterborne oil sample.
1.2 This practice is applicable to all waterborne oils taken from water bodies, either natural or man-made, such as open oceans, estuaries or bays, lakes, rivers, smaller streams, canals; or from beaches, marshes, or banks lining or edging these water systems. Generally, the waterborne oils float on the surface of the waters or collect on the land surfaces adjoining the waters, but occasionally these oils, or portions, are emulsified or dissolved in the waters, or are incorporated into the sediments underlying the waters, or into the organisms living in the water or sediments.
1.3 This practice as presently written proposes the use of specific analytical techniques described in the referenced ASTM standards. As additional techniques for characterizing waterborne oils are developed and written up as test methods, this practice will be revised.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
4.1 Identification of a recovered oil is determined by comparison with known oils selected because of their possible relationship to the particular recovered oil, for example, suspected or questioned sources. Thus, samples of such known oils must be collected and submitted along with the unknown for analysis. It is unlikely that identification of the sources of an unknown oil by itself can be made without direct matching, that is, solely with a library of analyses.
SCOPE
1.1 This practice covers the preparation for analysis of waterborne oils recovered from water. The identification is based upon the comparison of physical and chemical characteristics of the waterborne oils with oils from suspect sources. These oils may be of petroleum or vegetable/animal origin, or both. Seven procedures are given as follows:
Sections
Procedure A (for samples of more than 50 mL volume containing significant quantities of hydrocarbons with boiling points above 280 °C)
8 to 12
Procedure B (for samples containing significant quantities of hydrocarbons with boiling points above 280 °C)
13 to 17
Procedure C (for waterborne oils containing significant amounts of components boiling below 280 °C and to mixtures of these and higher boiling components)
18 to 22
Procedure D (for samples containing both petroleum and vegetable/animal derived oils)
23 to 27
Procedure E (for samples of light crudes and medium distillate fuels)
28 to 34
Procedure F (for thin films of oil-on-water)
35 to 39
Procedure G (for oil-soaked samples)
40 to 44
1.2 Procedures for the analytical examination of the waterborne oil samples are described in Practice D3415 and Test Methods D3328, D3414, and D3650. Refer to the individual oil identification test methods for the sample preparation method of choice. The deasphalting effects of the sample preparation method should be considered in selecting the best methods.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific caution statements are given in Sections 6 and 32.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard8 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Calcium Carbonate (CaCO3) buffered formalin (3 % to 5 %) can be used as a permanent preservative for zooplankton. Lugol’s iodine solution can be used to preserve zooplankton for up to one year. Thirty percent ethanol, 30 % glutaraldehyde, or 25 % vinegar (can use 3 % acetic acid solution) can be used for more temporary storage and preservation of zooplankton samples. A 25 % vinegar solution is preferred to preserve soft-bodied planktonic coelenterates.
SCOPE
1.1 This practice describes the proper procedures for preserving zooplankton samples with either formaldehyde, ethanol, glutaraldehyde, Lugol’s iodine solution, or vinegar (acetic acid).
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard2 pagesEnglish language
- Standard2 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This practice will be used most frequently to sample materials as received from the manufacturer in the original shipping container and prior to any resin-conditioning procedure. Since certain ion-exchange materials are supplied by the manufacturer in the dry or free-flowing state whereas others are supplied moist, it is necessary to employ two different sampling devices. Therefore, this practice is divided into Sampling Procedure—Dry or Free-Flowing Material (Section 8), and Sampling Procedure—Moist Material (Section 9).
5.2 Once the sample is obtained, it is necessary to protect the ion-exchange materials from changes. Samples should be placed in sealable, gasproof containers immediately.
SCOPE
1.1 These practices2 cover procedures for obtaining representative samples of ion-exchange materials. The following practices are included:
Sections
Practice A—Sampling from a Single Package and
Multiple Package Lots or Shipments
4 to 11
Practice B—Sampling from Fixed Bed Ion-Exchange
Equipment Having Unrestricted Head Room
12 to 16
Practice C—Sampling from Fixed Bed Ion-Exchange
Equipment Having Restricted Head Room
17 to 21
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard8 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The advantages of the Clarke-Bumpus plankton sampler are as follows:
5.1.1 It will sample a discrete depth or multiple depths, depending upon the sampling design.
5.1.2 It is a slow to medium speed sampler requiring a towing speed of three to five knots.
5.1.3 The sample size can be easily controlled.
5.1.4 The sampler is lightweight and can be used without auxiliary equipment.
5.1.5 It has a relatively high filtration efficiency factor of 0.88.
5.1.6 It is a versatile sampler and can be used in all but the shallowest waters.
5.1.7 The flowmeter records the amount of water that passes into the net.
5.1.8 Overspill of water at the mouth of the net due to excess speed of towing is of minimal consequence.
5.2 The disadvantages of the Clarke-Bumpus plankton sampler are as follows:
5.2.1 The flowmeter requires frequent maintenance including calibration and lubrication.
5.2.2 It is not suitable for use in very small areas or shallow waters.
5.3 There are several special considerations that shall be observed when using a Clarke-Bumpus plankton sampler. They are:
5.3.1 The flowmeter should be calibrated and serviced frequently to ensure efficient and accurate operation.
5.3.2 The sampler is relatively fragile, particularly the closing device and flowmeter. This necessitates careful deployment and recovery procedures.
5.3.3 Following each collection, the net must be thoroughly washed.
5.3.4 Special attention must be given to the strength of the cable and its attachment to avoid loss of the sampler.
5.3.5 The sampler should not be used in beds of macrophytes, in waters containing submerged objects, or close to the bottom.
5.3.6 The net should be inspected frequently for pin-size holes, tears, net deterioration, and other anomalies.
5.3.7 Following use, the wet net should be suspended full length in the air in subdued light and allowed to dry.
SCOPE
1.1 This practice covers the procedures for obtaining quantitative samples of a zooplankton community by use of a Clarke-Bumpus plankton sampler.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard2 pagesEnglish language
- Standard2 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The enterococci are indicators of the bacteriological quality for potable water, shellfish growing waters, ambient, and recreational waters. A direct relationship between swimming, associated gastroenteritis, and enterococci has been established through epidemiological studies and marine and fresh water bathing beaches. These studies have led to the development of criteria that can be used to establish bathing water standards based on established health-water quality relationships.
5.2 Since small or large volumes of water or dilutions thereof, can be analyzed by the membrane filter technique, a wide range of levels of enterococci in water can be enumerated and detected.
SCOPE
1.1 This test method covers a membrane filter (MF) procedure for the detection and enumeration of the enterococci bacteria in water. The enterococci, which include Entero-coccus faecalis (E. faecalis), E. faecium, and their varieties are commonly found in the feces of humans and other warm-blooded animals. Although some strains are ubiquitous and not related to fecal pollution, enterococci in water are an indication of fecal pollution and the possible presence of enteric pathogens. These bacteria are found in water and wastewater in a wide range of densities. The detection limit is one colony forming unit (CFU)/volume filtered.
1.2 This test method has been used successfully with temperate fresh and marine ambient waters, and wastewaters. It is the user’s responsibility to ensure the validity of this test method for waters of untested types.
1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are included for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 9.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard6 pagesEnglish language
- Standard6 pagesEnglish language
SIGNIFICANCE AND USE
4.1 The accuracy of depth measurements made by a fathometer or echo sounder requires a number of corrections because of the variability of sound or acoustic velocity in water with changes in temperature, salinity, and depth of water. In addition instability of the equipment can also result in significant errors. For additional information see Practice D5073.
4.2 Calibration of echo sounding instruments is absolutely critical in assuring the adequacy of depth measurements. When an echo sounder has been accurately calibrated, any observed (recorded) depth can be related to the true depth of water. Since the intended purpose of echo sounding is to measure the “true” depth, an independent “true” reference must be used.
4.3 A bar-check is the most wide-spread, easiest to construct, and most economical mechanical method to determine corrections for instrument and velocity errors.
4.4 This procedure explains the calibration of a fathometer or electronic depth sounder using a bar-check.
4.5 Bar-checking techniques and equipment are general in nature and may need to be modified for use in specific field conditions.
SCOPE
1.1 This practice provides the user with procedures used in manually calibrating the fathometer or electronic depth sounder. This narrative describes calibration terminology, describes acceptable environmental conditions for calibration, and describes the calibration procedures.
1.2 The references cited contain useful information in the construction and the correct operation of the calibration equipment.
1.3 Any references cited in this narrative to specific products or brand names are made for information only, and is intended to be descriptive, but not restrictive, of products that will perform satisfactorily.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The advantages of collecting zooplankton with pumps are as follows:
5.1.1 Sample size is more accurately controlled than with nets.
5.1.2 Discrete samples can be more easily obtained both vertically and horizontally.
5.1.3 Multiple or replicate samples can be more easily obtained.
5.1.4 The pumps are adaptable to a variety of ecosystems less than 30 m deep.
5.1.5 Sampling efficiency does not decrease with sample size.
5.2 The disadvantages of collecting zooplankton with pumps are as follows:
5.2.1 Pumps are bulky and require an electrical source.
5.2.2 Pumps are generally more costly than nets.
5.2.3 Pumps generally discriminate against collecting macroplankton.
5.2.4 Pump intake tubes may be avoided by the more motile zooplankton forms.
5.2.5 Requires a long, bulky, intake tube for deep water sampling.
5.3 There are several special considerations that should be observed when collecting zooplankton with a pump. They are:
5.3.1 Some pumps can fragment zooplankton and induce mortality due to their design.
5.3.2 The pump hose must be cleared before taking the next sample.
SCOPE
1.1 This practice covers the procedures for obtaining qualitative/quantitative samples of a zooplankton community by use of pumping systems.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard2 pagesEnglish language
- Standard2 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method is an alternative for the silt density index (SDI) method (Test Method D4189) with the aim to overcome inaccuracies related to a nonlinear relation with the fouling potential due to particulate matter concentration, absence of temperature correction, support pad, and time.
5.2 The MFI-0.45 can serve as a useful indication of the quantity of particulate matter.
5.3 The MFI-0.45 can be used to determine effectiveness of various processes such as filtration or clarification used to remove particulate matter.
5.4 The MFI-0.45 has empirically been correlated with fouling tendency of some water treatment equipment such as reverse osmosis (RO) devices.
SCOPE
1.1 This test method covers the determination of the modified fouling index (MFI) of water measured at constant pressure. This test can be used to indicate the fouling potential of reverse osmosis/nanofiltration (RO/NF) feed water due particulate matter and is applicable to low and high turbidity waters. Since the size, shape, and nature of particulate matter in water may vary, this test method is not an absolute measurement of the quantity of particulate matter.
1.2 This test method is not applicable for reagent-grade water Types I, II, and III of Specification D1193 or effluents from most reverse osmosis and ultra-filtration systems.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Matrix spiking of samples is commonly used to determine the bias under specific analytical conditions, or the applicability of a test method to a particular sample matrix, by determining the extent to which the added spike is recovered from the sample matrix under these conditions. Reactions or interactions of the analyte or component of interest with the sample matrix may cause a significant positive or negative effect on recovery and may render the chosen analytical, or monitoring, process ineffectual for that sample matrix.
5.2 Matrix spiking of samples can also be used to monitor the performance of a laboratory, individual instrument, or analyst as part of a regular quality assurance program. Changes in spike recoveries from the same or similar matrices over time may indicate variations in the quality of analyses and analytical results.
5.3 Spiking of samples may be performed in the field or in the laboratory, depending on what part of the analytical process is to be tested. Field spiking tests the recovery of the overall process, including preservation and shipping of the sample and may be considered a measure of the stability of the analytes in the matrix. Laboratory spiking tests the laboratory process only. Spiking of sample extracts, concentrates, or dilutions will be reflective of only that portion of the process subsequent to the addition of the spike.
5.4 Special precautions shall be observed when nonlaboratory personnel perform spiking in the field. It is recommended that all spike preparation work be performed in a laboratory by experienced analysts so that the field operation consists solely of adding a prepared spiking solution to the sample matrix. Training of field personnel and validation of their spiking techniques are necessary to ensure that spikes are added accurately and reproducibly. Consistent and acceptable recoveries from duplicate field spikes can be used to document the reproducibility of sampling and the spiking technique....
SCOPE
1.1 This guide covers the general technique of “spiking” aqueous samples with organic analytes or components. It is intended to be applicable to a broad range of organic materials in aqueous media. Although the specific details and handling procedures required for all types of compounds are not described, this general approach is given to serve as a guideline to the analyst in accurately preparing spiked samples for subsequent analysis or comparison. Guidance is also provided to aid the analyst in calculating recoveries and interpreting results. It is the responsibility of the analyst to determine whether the methods and materials cited here are compatible with the analytes of interest.
1.2 The procedures in this guide are focused on “matrix spike” preparation, analysis, results, and interpretation. The applicability of these procedures to the preparation of calibration standards, calibration check standards, laboratory control standards, reference materials, and other quality control materials by spiking is incidental. A sample (the matrix) is fortified (spiked) with the analyte of interest for a variety of analytical and quality control purposes. While the spiking of multiple sample test portions is discussed, the method of standard additions is not covered.
1.3 This guide is intended for use in conjunction with the individual analytical test method that provides procedures for analysis of the analyte or component of interest. The test method is used to determine an analyte or component's background level and, again after spiking, its now elevated level. Each test method typically provides procedures not only for samples, but also for calibration standards or analytical control solutions, or both. These procedures include preparation, handling, storage, preservation, and analysis techniques. These procedures are applicable by extension, using the analyst's judgement on a case-by-case basis, to spiking solutions, ...
- Guide7 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method is useful for characterization and rapid quantification of PAH mixtures including petroleum oils, fuels, creosotes, and industrial organic mixtures, either waterborne or obtained from tanks.
5.2 The unknown PAH mixture is first characterized by its fluorescence emission and synchronous scanning spectra. Then a suitable site-specific calibration standard with similar spectral characteristics is selected as described in Annex A1. This calibration standard may also be well-characterized by other independent methods such as gas chromatography (GC), GC-mass spectrometry (GC-MS), or high performance liquid chromatography (HPLC). Some suggested independent analytical methods are included in References (1-7)4 and Test Method D4657. Other analytical methods can be substituted by an experienced analyst depending on the intended data quality objectives. Peak maxima intensities of appropriate fluorescence emission spectra are then used to set up suitable calibration curves as a function of concentration. Further discussion of fluorescence techniques as applied to the characterization and quantification of PAHs and petroleum oils can be found in References (8-18).
5.3 For the purpose of the present test method polynuclear aromatic hydrocarbons are defined to include substituted polycyclic aromatic hydrocarbons with functional groups such as carboxyl acid, hydroxy, carbonyl and amino groups, and heterocycles giving similar fluorescence responses to PAHs of similar molecular weight ranges. If PAHs in the more classic definition, that is, unsubstituted PAHs, are desired, chemical reactions, extractions, or chromatographic procedures may be required to eliminate these other components. Fortunately, for the most commonly expected PAH mixtures, such substituted PAHs and heterocycles are not major components of the mixtures and do not cause serious errors.
SCOPE
1.1 This test method covers a means for quantifying or characterizing total polycyclic aromatic hydrocarbons (PAHs) by fluorescence spectroscopy (Fl) for waterborne samples. The characterization step is for the purpose of finding an appropriate calibration standard with similar emission and synchronous fluorescence spectra.
1.2 This test method is applicable to PAHs resulting from petroleum oils, fuel oils, creosotes, or industrial organic mixtures. Samples can be weathered or unweathered, but either the same material or appropriately characterized site-specific PAH or petroleum oil calibration standards with similar fluorescence spectra should be chosen. The degree of spectral similarity needed will depend on the desired level of quantification and on the required data quality objectives.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard11 pagesEnglish language
SIGNIFICANCE AND USE
4.1 This practice provides a general procedure for the solvent extraction of volatile and semi-volatile organic compounds from a water matrix. Solvent extraction is used as the initial step in the solvent extraction of organic constituents for the purpose of quantifying extractable organic compounds.
4.2 Typical detection limits that can be achieved using micro-extraction techniques with gas chromatography (GC) with flame ionization detector (FID), electron capture detector (ECD), or with a mass spectrometer (GC/MS) range from milligrams per litre (mg/L) to nanograms per litre (ng/L). The detection limit, linear concentration range, and sensitivity of the test method for a specific organic compound will depend upon the sample clean-up, injection volume, solvent to sample ratio, solvent concentration methods used, and the determinative technique employed.
4.3 Micro-extraction has the advantage of speed, simple extraction devices, and the use of small amounts of sample and solvents.
4.3.1 Selectivity can be improved by the choice of solvent (usually hexane or pentane) or mixed solvents, extraction time and temperature, and ionic strength of the solution.
4.3.2 Extraction devices can vary from the sample container itself to commercial devices specifically designed for micro-extraction. See 7.1 and 7.2.
4.3.3 A list of chlorinated organic compounds that can be determined by this practice includes both high and low boiling compounds or chemicals (see Table 1). (A) Based on the injection of chlorinated compounds in pentane solution, taking into consideration the 100:1 concentration of a water sample by the microextraction technique.
SCOPE
1.1 This practice covers standard procedures for extraction of volatile and semi-volatile organic compounds from water using small volumes of solvents.
1.2 The compounds of interest must have a greater solubility in the organic solvent than the water phase.
1.3 Not all of the solvents that can be used in micro extraction are addressed in this practice. The applicability of a solvent to extract the compound(s) of interest must be demonstrated before use.
1.4 This practice provides sample extracts suitable for any technique amenable to solvent injection such as gas chromatography or high performance liquid chromatography (HPLC).
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 9.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This practice is useful in identifying the major organic constituents in wastewater for support of effective in-plant or pollution control programs. Currently, the most practical means for tentatively identifying and measuring a range of volatile organic compounds is gas-liquid chromatography. Positive identification requires supplemental testing (for example, multiple columns, speciality detectors, spectroscopy, or a combination of these techniques).
SCOPE
1.1 This practice covers general guidance applicable to certain test methods for the qualitative and quantitative determination of specific organic compounds, or classes of compounds, in water by direct aqueous injection gas chromatography (1, 2, 3, 4).2
1.2 Volatile organic compounds at aqueous concentrations greater than about 1 mg/L can generally be determined by direct aqueous injection gas chromatography.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard7 pagesEnglish language
SIGNIFICANCE AND USE
4.1 There are four basic steps necessary to obtain meaningful analytical data: preparation of the sample container, sampling, sample preservation, and analysis. In fact these four basic steps comprise the analytical method and for this reason no step should be overlooked. Although the significance of preservation is dependent upon the time between sampling and the analysis, unless the analysis is accomplished within 2 h after sampling, preservation is preferred and usually required.
SCOPE
1.1 These practices cover the various means of (1) preparing sample containers used for collection of waters to be analyzed for organic constituents and (2) preservation of such samples from the time of sample collection until the time of analysis.
1.2 The sample preservation practice is dependent upon the specific analysis to be conducted. See Section 9 for preservation practices listed with the corresponding applicable general and specific constituent test method. The preservation method for waterborne oils is given in Practice D3325. Use of the information given herein will make it possible to choose the minimum number of sample preservation practices necessary to ensure the integrity of a sample designated for multiple analysis. For further considerations of sample preservation, see the Manual on Water.2
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see 6.7, 6.24, and 8.1.3.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard7 pagesEnglish language
SIGNIFICANCE AND USE
5.1 P. aeruginosa is an opportunistic pathogen and has been linked as the causative agent of numerous infections that may be transmitted through a contaminated water supply to a susceptible host.
Note 1: Fecal waste is >95 % E. coli which is found in humans and warm blooded animals.
5.2 The membrane filtration procedure described is a rapid and reliable test method of detecting P. aeruginosa in water.
SCOPE
1.1 The test method covers the isolation and enumeration of Pseudomonas aeruginosa. Testing was performed on spiked samples using reagent grade water as the diluent from surface waters; recreational waters; ground water, water supplies; especially rural nonchlorinated sources; waste water; and saline waters. The detection limit of this test method is one microorganism per 100 mL.
1.2 This test method was used successfully with reagent water. It is the user's responsibility to ensure the validity of this test method for surface waters, recreational waters, ground water, rural nonchlorinated sources; waste water; and saline waters.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 10.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
4.1 This practice provides uniform guidance for cleaning the laboratory glassware, plasticware, and equipment used in routine microbiological analyses. However, tests that are extremely sensitive to toxic agents (such as virus assays) may require more stringent cleaning practices.2
SCOPE
1.1 In microbiology, clean glassware is crucial to ensure valid results. Previously used or new glassware must be thoroughly cleaned. Laboratory ware and equipment that are not chemically clean are responsible for considerable losses in personnel time and supplies in many laboratories. These losses may occur as down time when experiments clearly have been adversely affected and as invalid data that are often attributed to experimental error. Chemical contaminants that adversely affect experimental results are not always easily detected. This practice describes the procedures for producing chemically clean glassware.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific precautions, see Section 6, 5.7.3.1, and 8.3.1.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
5.1 N-methylcarbamates and n-methylcarbomoyloximes are used in agriculture as insecticides and herbicides. They are sometimes found in both surface and ground waters and can be toxic to animals and plants at moderate to high concentrations. The manufacturing precursors and degradation products may be equally as hazardous to the environment.
SCOPE
1.1 This is a high-performance liquid chromatographic (HPLC) test method applicable to the determination of certain n-methylcarbamoyloximes and n-methylcarbamates in ground water and finished drinking water (1).2 This test method is applicable to any carbamate analyte that can be hydrolyzed to a primary amine. The following compounds have been validated using this test method:
Analyte
Chemical Abstract Services
Registry Number A
Aldicarb
116-06-3
Aldicarb sulfone
1646-88-4
Aldicarb sulfoxide
1646-87-3
Baygon
114-26-1
Carbaryl
63-25-2
Carbofuran
1563-66-2
3-Hydroxycarbofuran
16655-82-6
Methiocarb
2032-65-7
Methomyl
16752-77-5
Oxamyl
23135-22-0
1.2 This test method has been validated in a collaborative round-robin study (2) and estimated detection limits (EDLs) have been determined for the analytes listed in 1.1 (Table 1). Observed detection limits may vary between ground waters, depending on the nature of interferences in the sample matrix and the specific instrumentation used.
1.3 This test method is restricted to use by, or under the supervision of, analysts experienced in both the use of liquid chromatography and the interpretation of liquid chromatograms. Each analyst should demonstrate an ability to generate acceptable results with this test method using the procedure described in 12.3.
1.4 When this test method is used to analyze unfamiliar samples for any or all of the analytes listed in 1.1, analyte identifications should be confirmed by at least one additional qualitative technique.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Additional guidance on laboratory safety is available and suitable references for the information are provided (3-5).
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard16 pagesEnglish language
ABSTRACT
This practice covers determination of the quantitative and qualitative species composition of fish in a specified area. The successful use of this technique is dependent on: (1) preventing fish from escaping the sample area and (2) retrieving all affected fish, which may take up to three days. This practice is useful in both short- and long-term studies for management and impact assessment purposes. The sample area is blocked off with a small mesh net(s) and the volume of water to be treated is calculated. The required quantity of rotenone is diluted and distributed throughout the water column in the sample area. All fish should be affected and they should be collected for processing.
SCOPE
1.1 This practice covers determination of the quantitative and qualitative species composition of fish in a specified area. The successful use of this technique is dependent on: (1) preventing fish from escaping the sample area and (2) retrieving all affected fish, which may take up to three days.
1.2 Advantages:
1.2.1 Easily detoxified.
1.2.2 All native freshwater fish are susceptible, but it has low toxicity to mammals and birds.
1.2.3 At low concentrations fish toxicity depends on species, age, and size.
1.2.4 The suffocating action is reversible.
1.3 Limitations:
1.3.1 It is less effective in cold (below 20 °C) and highly alkaline water.
1.3.2 Smaller fish and those without air bladders usually do not float.
1.3.3 Completely random selection of sample areas is not possible.
1.3.4 Overkill beyond sample area can sometimes occur.
1.3.5 Food web organisms may be eliminated.
1.4 Applications—This practice is useful in both short- and long-term studies for management and impact assessment purposes. It is adaptable to both lotic and lentic situations in littoral and limnetic areas.
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazards, see Section 7.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard3 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method is used for determination of the carbon content of water from a variety of natural, domestic, and industrial sources. In its most common form, this test method is used to measure organic carbon as a means of monitoring organic pollutants in high purity and drinking water. These measurements are also used in monitoring waste treatment processes.
5.2 The relationship of TOC to other water quality parameters such as chemical oxygen demand (COD) and total oxygen demand (TOD) is described in the literature (6).
SCOPE
1.1 This test method covers the determination of total carbon (TC), inorganic carbon (IC), and total organic carbon (TOC) in water in the range from 0.5 mg/L to 30 mg/L of carbon. Higher levels may be determined by sample dilution. The test method utilizes ultraviolet-persulfate oxidation of organic carbon, coupled with a CO2 selective membrane to recover the CO2 into deionized water. The change in conductivity of the deionized water is measured and related to carbon concentration in the oxidized sample. Inorganic carbon is determined in a similar manner without the requirement for oxidation. In both cases, the sample is acidified to facilitate CO2 recovery through the membrane. The relationship between the conductivity measurement and carbon concentration is described by a set of chemometric equations for the chemical equilibrium of CO2, HCO3−, H+, and the relationship between the ionic concentrations and the conductivity. The chemometric model includes the temperature dependence of the equilibrium constants and the specific conductances.
1.2 This test method has the advantage of a very high sensitivity detector that allows very low detection levels on relatively small volumes of sample. Also, use of two measurement channels allows determination of CO2 in the sample independently of organic carbon. Isolation of the conductivity detector from the sample by the CO2 selective membrane results in a very stable calibration, with minimal interferences.
1.3 This test method was used successfully with reagent water spiked with sodium bicarbonate and various organic materials. It is the user's responsibility to ensure the validity of this test method for waters of untested matrices.
1.4 This test method is applicable only to carbonaceous matter in the sample that can be introduced into the reaction zone. The injector opening size generally limits the maximum size of particles that can be introduced.
1.5 In addition to laboratory analyses, this test method may be applied to on line monitoring.
1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard7 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method is used for determination of the carbon content of water from a variety of natural, domestic, and industrial sources. In its most common form, this test method is used to measure organic carbon as a means of monitoring organic pollutants in industrial wastewater. These measurements are also used in monitoring waste treatment processes.
5.2 The relationship of TOC to other water quality parameters such as chemical oxygen demand (COD) and total oxygen demand (TOD) is described in the literature.4
SCOPE
1.1 This test method covers the determination of total carbon (TC), inorganic carbon (IC), and total organic carbon (TOC) in water, wastewater, and seawater in the range from 0.1 mg/L to 4000 mg/L of carbon.
1.2 This test method was used successfully with reagent water spiked with sodium carbonate, acetic acid, and pyridine. It is the user's responsibility to ensure the validity of this test method for waters of untested matrices.
1.3 This test method is applicable only to carbonaceous matter in the sample that can be introduced into the reaction zone. The syringe needle or injector opening size generally limit the maximum size of particles that can be so introduced.
1.4 In addition to laboratory analyses, this test method may be applied to stream monitoring.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard6 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This practice is particularly useful for determining the discharge at a gauging station or a location where discharge information is repeatedly needed.
5.2 This practice is applicable only for open-channel flow conditions where channel hydraulics permit a stable relation between stage and discharge.
SCOPE
1.1 This practice covers the development of a curve relating stage (elevation) to discharge. Standard test methods have been documented for measuring discharge and for measuring stage (see Practice D3858, and Test Methods D5129, D5130, D5243, D5388, and D5413). This practice takes the discharge and stage determined by each respective test method and shows a relation between them using a curved line. This curved line is called a stage-discharge relation or rating curve.
1.2 The procedures described in this practice are used commonly by those responsible for investigations of streamflow, for example, the U.S. Geological Survey, Army Corps of Engineers, Bureau of Reclamation, and U.S Agriculture Research Service. For the most part, these procedures are adapted from reports of the U.S. Geological Survey.2,3
1.3 The procedures described in this practice apply only to simple freely flowing open-channel flow. Ratings for complex hydraulic conditions of extremely low slope channels using multiple-stage inputs, channels affected by man-induced regulation, or tidal conditions are not described. These types of ratings are described in detail in the documents listed in Footnotes 2 and 3.2,3
1.4 This practice uses the results of current-meter discharge measurements or indirect discharge measurements and the corresponding measured stage to define as much of the stage-discharge relation curve as possible. A theoretical curve is developed for the full range of stage and discharge to shape the curve.
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Sulfate-reducing bacteria are widely distributed in marine and fresh water muds which, in consequence, frequently are laden with the hydrogen sulfide produced by these organisms during dissimilatory sulfate reduction.
5.2 It has been reported that Desulfovibrio spp. can form as much as 10 g of sulfide per litre during active multiplication. Sulfate-reducing bacteria can cause the external or internal corrosion of water or wastewater pipelines and pipelines for petroleum and natural gas. The formation of galvanic cells by massive growth of sulfate-reducing bacteria under suitable conditions makes the corrosion much worse than just the effect of the hydrogen sulfide on the metal or concrete.
SCOPE
1.1 These test methods cover the procedure for the detection and enumeration by the most probable number (MPN) technique of sulfate-reducing bacteria in water or water-formed deposits.
1.2 Two media preparations are provided. Medium A which is prepared with reagent grade water, and Medium B which is prepared using the water to be sampled as the water source. Medium B is offered for those special conditions where sulfate-reducing bacterial strains have adapted to atypical non-fresh water environment.
1.3 For the isolation and enumeration of thermophilic sulfate-reducing bacteria encountered in waters associated with oil and gas production, all broths, dilution blanks, and incubations must be maintained at temperatures of at least 45 °C and preferably within 5 °C at the sample temperature.
1.4 The sensitivity of these test methods can be increased by purging the dilution blanks and tubes of media with nitrogen immediately prior to use.
1.5 The analyst should be aware that adequate collaborative data for precision and bias statements as required by Practice D2777 are not provided. See Section 11 for details.
1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Preliminary studies have identified polymeric organic compounds as contaminants in treated drinking water, wastewater, surface water, ground water, and marine waters. These polymers may be harmful to the environment and adversely affect human health, and in these circumstances, mass estimation is commonly required. A universal, analytical method will help to normalize data from around the world and better understand which polymers are most frequently found in various climatic and geological locations (5-7). Pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS) has many advantages in that both polymer identification and mass quantification can be easily accomplished by chromatographic separation in combination with mass spectral analysis.
SCOPE
1.1 In this pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS) test method, an analytical protocol validated specifically for the analysis of water with high to low suspended solids is described. This test method will standardize the identification and simultaneous quantitation of organic polymer particles and fibers in water. It has been designed for and applies to all microplastic particles and fibers, and is intended for use with treated drinking water, surface waters, wastewater influent and effluent (secondary and tertiary), and marine waters. This test method is not limited to these particular water matrices; however, the applicability of this test method to other aqueous matrices shall be demonstrated.
1.2 Microgram quantities of a sample containing microplastics are pyrolyzed (Py) at 600 °C. The pyrolyzates are separated on an analytical column (GC) and detected using a 70-eV electron impact mass spectrometer (MS). Polymers often have similar pyrograms, making it difficult to differentiate the pyrolyzates for a given polymer from those of the composite sample. In this test method, ion ratios at predetermined retention times to facilitate the identification of each polymer present in a sample containing microplastics are compared.
1.3 This test method is to be used in conjunction with Practices D8332, D8333, and D8402. These ASTM International standards enable the collection and preparation of water samples with high, medium, or low suspended solids for the identification and quantification of microplastic particles and fibers without compromising the integrity of the microplastics. This test method is applicable to microplastic fibers and particles, including sizes defined as a nanoparticle; this is a natural extension of this test method because Py-GC/MS technology responds to the total mass of the sample independent of individual particle sizes. The uniformity of particle size influences the reproducibility of the pyrogram and samples with microplastics should be reduced to a fine powder with the final particle size diameter on the order of less than 0.2 mm.
1.4 It is the responsibility of the user to ensure the validity of this test method for untested matrices.
1.5 Units—The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard26 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This guide is general and intended as a planning guide. To satisfactorily monitor a specific site, an investigator must sometimes design specific installation structures or modify those given in this guide to meet the requirements of the site in question. Because of the dynamic nature of the sediment transport process, the extent to which characteristics such as mass concentration and particle-size distribution are accurately represented in the monitoring program depends on the type of equipment used and method of collection of the SSC samples used to calibrate the optical readings. Sediment concentration is highly variable in both time and space. Numerous samples must be collected and analyzed with proper equipment and standardized methods for the rating of the optical equipment at a particular site (see Guide D4411 and Practice D3977).
5.2 All optical equipment have an upper limit for valid readings, beyond which the meter will not read properly, commonly referred to as “blacking out.” If upper range of SSC are expected to cause optical instrument black out, then some other means should be devised, such as automatic pumping samplers, to collect samples during this period. See Edwards and Glysson (1)3 and Glysson (2) for information on collection of suspended sediment samples using pumping samplers. It should be noted that other technologies, such as lasers and acoustic dopplers, are also being used to monitor SSC continuously.
5.3 The user of this guide should realize that because different technologies and different models of the same technology of turbidity meters can produce significantly different outputs for the same environmental sample, only one manufacturer and model of the turbidity meter can be used to develop the relationship between the SSC and turbidity readings at a site. If a different manufacturer or a different model type of turbidity meter is used, a new relationship will need to be develop for the site.
SCOPE
1.1 This guide covers the equipment and basic procedures for installation, operation, and calibration of optical equipment as a surrogate for the continuous determination of suspended-sediment concentration (SSC) in open channel flow.
1.2 This guide emphasizes general principles for the application of optical measurements to be used to estimate suspended-sediment concentration (SSC) in water. Only in a few instances are step-by-step instructions given. Continuous monitoring is a field-based operation, methods and equipment are usually modified to suit local conditions. The modification process depends upon the operator skill and judgment.
1.3 This guide covers the use of the output from an optical instrument, such as turbidity and suspended-solids meters, to record data that can be correlated with suspended-sediment concentration. It does not cover the process of collecting data for continuous turbidity record, which would require additional calibration of the turbidity readings to the mean turbidity of the measurement cross section. For the purposes of this method it is assumed that the dependent variable will be mean cross-sectional suspended-sediment concentration data.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Guide14 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Industrialized and urban areas have been found to deposit a number of toxic elements into environments where those elements were previously either not present or were found in trace amounts. Consequently, it is important to be able to measure the concentration of these pollution-deposited elements to properly study pollution effects.
5.2 This procedure is concerned with the pollution-related trace elements that are described in 4.1 rather than those elements incorporated in the silicate lattices of the minerals from which the sediments were derived. These pollution-related trace elements are released into the water and readsorbed by the sediments with changes in general water quality, pH in particular. These elements are a serious source of pollution. The elements locked in the silicate lattices are not readily available in the biosphere (1-8).
5.3 When comparing the trace element concentrations, it is important to consider the particle sizes to be analyzed (8, 9).
5.3.1 The finer the particle the greater the surface area. Consequently, a potentially greater amount of a given trace element can be adsorbed on the surface of fine, particulate samples (4). For particle sizes smaller than 80 mesh, metal content is no longer dependent on surface area. Therefore, if this portion of the sediment is used, the analysis with respect to sample type (that is, sand, salt, or clay) is normalized. It has also been observed that the greatest contrast between anomalous and background samples is obtained when less than 80-mesh portion of the sediment is used (4, 5).
5.3.2 After the samples have been dried, care must be taken not to grind the sample in such a way to alter the natural particle-size distribution (14.1). Fracturing a particle disrupts the silicate lattice and makes available those elements which otherwise are not easily digested (6). Normally, aggregates of dried, natural soils, sediments, and many clays dissociate once the reagents are added (14.3 and 1...
SCOPE
1.1 These practices describe the partial extraction of soils, bottom sediments, suspended sediments, and waterborne materials to determine the extractable concentrations of certain trace elements.
1.1.1 Practice A is capable of extracting concentrations of aluminum, boron, barium, cadmium, calcium, chromium, cobalt, copper, iron, lead, magnesium, manganese, molybdenum, nickel, potassium, sodium, strontium, vanadium, and zinc from the preceding materials. Other metals may be determined using this practice. This extraction is the more vigorous and more complicated of the two.
1.1.2 Practice B is capable of extracting concentrations of aluminum, cadmium, chromium, cobalt, copper, iron, lead, manganese, nickel, and zinc from the preceding materials. Other metals may be determined using this practice. This extraction is less vigorous and less complicated than Practice A.
1.2 These practices describe three means of preparing samples prior to digestion:
1.2.1 Freeze-drying.
1.2.2 Air-drying at room temperature.
1.2.3 Accelerated air-drying, for example, 95 °C.
1.3 The detection limit and linear concentration range of each procedure for each element is dependent on the atomic absorption spectrophotometric or other technique employed and may be found in the manual accompanying the instrument used. Also see various ASTM test methods for determining specific metals using atomic absorption spectrophotometric techniques.
1.3.1 The sensitivity of the practice can be adjusted by varying the sample size (14.2) or the dilution of the sample (14.6), or both.
1.4 Extractable trace element analysis provides more information than total metal analysis for the detection of pollutants, since absorption, complexation, and precipitation are the methods by which metals from polluted waters are retained in sediments.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are inc...
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
4.1 Proper operation and maintenance of RO and NF systems are key factors in obtaining successful performance. This guide provides the necessary input for the evaluation of the performance of the RO and NF systems, the pretreatment system, and the mechanical equipment in the plant.
4.2 This guide is for general guidance only and must not be used in place of the operating manual for a particular plant.
4.3 Site-dependent factors prevent specific recommendations for all recordkeeping. Thus, only the more general recordkeeping is covered by this guide.
4.4 This guide can be used for both brackish and seawater systems which contain either spiral-wound or hollow-fiber devices.
SCOPE
1.1 This guide covers procedures for well-defined recordkeeping of reverse osmosis (RO) and nanofiltration (NF) systems.
1.2 This guide includes a start-up report, recordkeeping of RO and NF operating data, recordkeeping of pretreatment operating data, and a maintenance log.
1.3 This guide is applicable to waters including brackish waters and seawaters but is not necessarily applicable to wastewaters.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Guide3 pagesEnglish language
SIGNIFICANCE AND USE
4.1 Most waters rarely contain more than trace concentrations of cobalt from natural sources. Although trace amounts of cobalt seem to be essential to the nutrition of some animals, large amounts have pronounced toxic effects on both plant and animal life.
SCOPE
1.1 These test methods cover the determination of dissolved and total recoverable cobalt in water and wastewater 2 by atomic absorption spectrophotometry. Three test methods are included as follows:
Concentration Range
Sections
Test Method A—Atomic Absorption, Direct
0.1 mg/L to 10 mg/L
7 to 16
Test Method B—Atomic Absorption, Chelation-Extraction
10 μg/L to 1000 μg/L
17 to 26
Test Method C—Atomic Absorption, Graphite Furnace
5 μg/L to 100 μg/L
27 to 36
1.2 Test Method A has been used successfully with reagent water, potable water, river water, and wastewater. Test Method B has been used successfully with reagent water, potable water, river water, sea water and brine. Test Method C was successfully evaluated in reagent water, artificial seawater, river water, tap water, and a synthetic brine. It is the analyst's responsibility to ensure the validity of these test methods for other matrices.
1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see 11.8.1, 21.12, and 23.10.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard12 pagesEnglish language
SIGNIFICANCE AND USE
4.1 These test methods are significant because the concentration of beryllium in water must be measured accurately in order to evaluate potential health and environmental effects.
SCOPE
1.1 These test methods cover the determination of dissolved and total recoverable beryllium in most waters and wastewaters:
Concentration
Range
Sections
Test Method A–Atomic Absorption, Direct
10 μg/L to 500 μg/L
7 to 17
Test Method B–Atomic Absorption, Graphite Furnace
10 μg/L to 50 μg/L
18 to 26
1.2 The analyst should direct attention to the precision and bias statements for each test method. It is the user's responsibility to ensure the validity of these test methods for waters of untested matrices.
1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 12 and 24.4.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard8 pagesEnglish language
SIGNIFICANCE AND USE
5.1 This test method is useful for the determination of element concentrations in many natural waters. It has the capability for the simultaneous determination of up to 15 separate elements. High analysis sensitivity can be achieved for some elements, such as boron and vanadium.
SCOPE
1.1 This test method covers the determination of dissolved and total recoverable elements in water, which includes drinking water, lake water, river water, sea water, snow, and Type II reagent water by direct current plasma atomic emission spectroscopy (DCP).
1.2 The information on precision and bias may not apply to other waters.
1.3 This test method is applicable to the 15 elements listed in Annex A1 (Table A1.1) and covers the ranges in Table 1.
1.4 This test method is not applicable to brines unless the sample matrix can be matched or the sample can be diluted by a factor of 200 up to 500 and still maintain the analyte concentration above the detection limit.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard8 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Pesticides and PCBs are Environmental Protection Agency (EPA)-regulated contaminants in treated drinking water, wastewater, and ground water. Liquid-liquid and solid-phase extraction (SPE) are generally applicable procedures for extracting these target analytes before GC/MS/MS analysis.
5.2 This test method is applicable to pesticides that are extracted from aqueous solution using methylene chloride and can be chromatographed and detected using tandem mass spectrometry procedures. Table 1 lists pesticides and Table 2 lists PCBs validated by this test method. This test method is not limited to the compounds listed in Table 1 or Table 2; however, the applicability of the test method to other compounds shall be demonstrated. Refer to Guide E2857 for guidance in validating the method for additional parameters.
5.3 Analyte concentrations up to approximately 250 ng/L may be determined. Analytes that are inefficiently extracted from water will not be detected when present at low concentrations, but they can be measured with acceptable accuracy and precision when present in sufficient amounts.
5.4 Analytes that are not separated chromatographically but that have different transitions can be identified and quantitatively measured.
5.5 This test method may be used to determine the concentrations of Aroclor6 mixtures or PCB congeners, or both, present in the sample. See Appendix X1 and Appendix X2 for suggested transitions and collisional energies for all 209 congeners. Separation of all 209 congeners may not be possible and may require additional GC columns and operating conditions. Analysis of all congeners is not expected to be achieved by this test method.
5.6 Method detection limits (MDL) and minimum reporting level (MRL) for analytes in Tables 1 and 2 are given in Table 3. These limits must be met if the method is used for National Pollutant Discharge Elimination System (NPDES) reporting. (A) Priority Pollutant listed in Table 1 of EPA Method 608.3.(...
SCOPE
1.1 This test method covers the identification and simultaneous measurement of extractable chlorinated pesticides and polychlorinated biphenyls (PCBs) by gas chromatography/mass spectrometry/mass spectrometry (GC/MS/MS).
1.2 This test method has been validated for wastewater influents, effluents, industrial discharges, surface water, and ground water.
1.3 This test method is not limited to these particular aqueous matrices; however, the applicability of this test method to other aqueous matrices shall be demonstrated.
1.4 This test method is restricted to use by or under the supervision of analysts experienced in the use of a gas chromatograph with tandem mass spectrometry. Each laboratory that uses this test method shall demonstrate the ability to generate results that meet or exceed the performance criteria of this test method.
1.5 If sensitivity permits, compound tentative identification of unknowns may be made by analyzing the extract in full-scan mode or, if the system allows simultaneous timed single-reaction monitoring (SRM)/full-scan acquisition. Identify unknown peaks according to Guide D4128.
1.6 This test method is performance-based. Minor modifications, as allowed by CFR 40 Part 136.6, may be made to improve the method performance, but changes may not be made to the extraction, the extraction solvent, sample-to-solvent ratio, or the MS/MS detection technique.
1.7 Units—The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.9 This international standard was developed in accordance with internationally recognized princ...
- Standard19 pagesEnglish language
SIGNIFICANCE AND USE
4.1 Herbicides, insecticides, and many industrial effluents contain arsenic and are potential sources of water pollution. Arsenic is significant because of its adverse physiological effects on humans.
SCOPE
1.1 These test methods2 cover the photometric and atomic absorption determination of arsenic in most waters and wastewaters. Three test methods are given as follows:
Concentration
Range
Sections
Test Method A—Silver Diethyldithio-
carbamate Colorimetric
5 μg/L to 250 μg/L
7 to 16
Test Method B—Atomic Absorption,
Hydride Generation
1 μg/L to 20 μg/L
17 to 26
Test Method C—Atomic Absorption,
Graphite Furnace
5 μg/L to 100 μg/L
27 to 36
1.2 The analyst should direct attention to the precision and bias statements for each test method. It is the user's responsibility to ensure the validity of these test methods for waters of untested matrices.
1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see 11.1 and 20.2.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard12 pagesEnglish language
SIGNIFICANCE AND USE
4.1 In most natural waters selenium concentrations seldom exceed 10 μg/L. However, the runoff from certain types of seleniferous soils at various times of the year can produce concentrations as high as several hundred micrograms per litre. Additionally, industrial contamination can be a significant source of selenium in rivers and streams.
4.2 High concentrations of selenium in drinking water have been suspected of being toxic to animal life. Selenium is a priority pollutant and all public water agencies are required to monitor its concentration.
4.3 These test methods determine the dominant species of selenium reportedly found in most natural and wastewaters, including selenities, selenates, and organo-selenium compounds.
SCOPE
1.1 These test methods cover the determination of dissolved and total recoverable selenium in most waters and wastewaters. Both test methods utilize atomic absorption procedures, as follows:
Sections
Test Method A—Gaseous Hydride AAS2, 3
7 – 16
Test Method B—Graphite Furnace AAS
17 – 26
1.2 These test methods are applicable to both inorganic and organic forms of dissolved selenium. They are applicable also to particulate forms of the element, provided that they are solubilized in the appropriate acid digestion step. However, certain selenium-containing heavy metallic sediments may not undergo digestion.
1.3 These test methods are most applicable within the following ranges:
Test Method A—Gaseous Hydride AAS2, 3
1 μg/L to 20 μg/L
Test Method B—Graphite Furnace AAS
2 μg/L to 100 μg/L
These ranges may be extended (with a corresponding loss in precision) by decreasing the sample size or diluting the original sample, but concentrations much greater than the upper limits are more conveniently determined by flame atomic absorption spectrometry.
1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see 11.12 and 13.14.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard11 pagesEnglish language
SIGNIFICANCE AND USE
4.1 Since the two tendencies are inseparable for a metal to corrode and for water and the materials it contains to promote or inhibit corrosion, the corrosion rate of a material in water is determined in relative, rather than absolute, terms. The relative tendency for a material to corrode is determined by measuring its rate of corrosion and comparing it with the corrosion rates of other materials in the same water environment. Conversely, the relative tendency of water to promote or inhibit corrosion can be determined by comparing the corrosion rate of a material in the water with the corrosion rates of the same material in other waters. Such tests are useful, for example, for evaluating the effects of corrosion inhibitors added to the water. Examples of systems in which this method can be used include, but are not limited to, open recirculating cooling water, closed chilled water, and hydronic heating systems.
SCOPE
1.1 This test method covers the determination of the corrosion rate in a water system, in the absence of heat transfer.
1.1.1 This is accomplished by measuring the weight loss of metal specimens, also called coupons, and evaluating pitting. Weight loss provides the means to calculate the average corrosion rate. Pitting is a form of localized corrosion.
1.1.2 The rate of corrosion of a metal immersed in water is a function of both the characteristics of the water itself and the materials it contains to promote or inhibit corrosion.
1.2 The test method employs flat, rectangular-shaped metal coupons which are mounted on pipe plugs and exposed to the water flowing in piping in municipal, building, and industrial water systems using a side stream corrosion specimen rack.
1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard8 pagesEnglish language
- Standard8 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Cyanide and hydrogen cyanide are highly toxic. Regulations have been established to require the monitoring of cyanide in industrial and domestic wastes and surface waters.3
5.2 This test method is applicable for natural water, saline waters, metallurgical process solutions, and wastewater effluent.
5.3 The method may be used for process control in wastewater treatment facilities.
SCOPE
1.1 This test method is used to determine the concentration of available inorganic cyanide in an aqueous wastewater or effluent. The method detects the cyanides that are free (HCN and CN-) and metal-cyanide complexes that are easily dissociated into free cyanide ions. The method does not detect the less toxic strong metal-cyanide complexes, cyanides that are not “amenable to chlorination.”
1.2 Total cyanide can be determined for samples that have been distilled as described in Test Methods D2036, Test Method A, Total Cyanides after Distillation. The cyanide complexes are dissociated and absorbed into the sodium hydroxide capture solution, which can be analyzed with this test method; therefore, ligand exchange reagents from 8.12 and 8.13 would not be required when determining total cyanide after distillation.
1.3 This procedure is applicable over a range of approximately 2 μg/L to 400 μg/L (parts per billion) available cyanides. Higher concentrations can be analyzed by dilution or lower injection volume.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in 8.6 and Section 9.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard8 pagesEnglish language
SIGNIFICANCE AND USE
5.1 The mathematical and statistical techniques described in this guide support implementation of the calibration requirements of Practice D7282 and the guidance for uncertainty analysis given in Guide D8293. The guidance is intended for use either by qualified specialists at a radioanalytical laboratory or by developers of software for calibration of nuclear instruments.
5.2 Applications for single-point calibrations might include:
5.2.1 Alpha-particle spectrometry,
5.2.2 Gas proportional counters used for thin sources with negligible attenuation, and
5.2.3 Gamma-ray spectrometers used for single nuclides.
5.3 Applications for calibration curves determined by LLS might include:
5.3.1 Mass attenuation curves for gas proportional counters (polynomial), and
5.3.2 Quench calibration curves for liquid scintillation counters (polynomial).
5.4 Applications for calibration curves determined by NLLS might include:
5.4.1 Gamma-ray spectrometry across a range of gamma-ray energies,
5.4.2 Mass attenuation curves for gas proportional counters, and
5.4.3 Quench calibration curves for liquid scintillation counters.
5.5 Although this guide focuses on efficiency calibrations for nuclear instruments, the same general principles and paradigms should apply to other types of calibrations and to other instruments, as long as there are valid uncertainty models for the calibration data.
SCOPE
1.1 This guide describes data analysis for efficiency calibrations of nuclear instruments using radioactive sources. It includes the calculation of the calibration parameters, evaluation and use of their uncertainties and covariances, and testing of the calibration data for outliers and overall lack of fit. It also provides guidelines for summarizing and reporting the results of a calibration.
1.2 The instrument counting efficiency is assumed to be independent of the radiation emission rate.
1.3 Guidance is provided for both single-point calibrations and calibration curves.
1.4 The guidance presumes the existence of measurement uncertainty models to provide statistical weighting factors for the calibration data.
1.5 This guide does not cover calibrations involving physically-based computer simulations.
1.6 The system of units for this guide is not specified. Dimensional quantities in the guide are presented only as illustrations of calculation methods. The examples are not binding on products or test methods treated.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Guide14 pagesEnglish language
SIGNIFICANCE AND USE
4.1 This guide provides standard terminology for use in identifying and describing the different chemical forms of cyanide. The complex nature of cyanide chemistry, existence of numerous distinct chemical forms as well as the various regulatory distinctions that may be made can lead to confusion in technical discussions on cyanide and in the selection of appropriate methods for its analysis. This guide is intended to provide clarification and a common framework of terms and definitions to facilitate discussions and referencing different cyanide chemical species and groups of cyanide compounds.
4.2 The use of such common terminology is particularly important from an environmental perspective because certain forms of cyanide are considered to be toxic. Therefore, their release into the environment is regulated by federal and state agencies. Thus a general understanding of cyanide chemistry and species definitions is needed for proper wastewater management and testing.
SCOPE
1.1 This guide defines guidance based on a consensus of viewpoints for interpretation of test results to identify various chemical forms of cyanide. It is intended to provide a general understanding of the chemical nature of distinct cyanide species as related to chemical analysis and environmental fate and transport.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Guide6 pagesEnglish language
SIGNIFICANCE AND USE
4.1 Turbidity is undesirable in drinking water, plant effluent waters, water for food and beverage processing, and for a large number of other water dependent manufacturing processes. Removal of suspended matter is accomplished by coagulation, settling, and filtration. Measurement of turbidity provides a rapid means of process control to determine when, how, and to what extent the water must be treated to meet specifications.
4.2 This test method is suitable for the on-line monitoring of turbidity such as that found in drinking water, process water, and high purity industrial waters.
4.3 The instrumentation used must allow for the continuous on-line monitoring of a sample stream.
4.4 When reporting the measured result, appropriate units should also be reported. The units are reflective of the technology used to generate the result, and if necessary, provide more adequate comparison to historical data sets.
4.4.1 Table 1 describing technologies and reporting results. Those technologies listed are appropriate for the range of measurement prescribed in this test method are mentioned, though others may come available. Fig. X3.1 from Appendix X3 contains a flowchart to assist in technology selection.
4.4.2 For a specific design that falls outside of these reporting ranges, the turbidity should be reported in TU with a subscripted wavelength value to characterize the light source that was used.
4.4.3 Ratio white light turbidimeters are common as bench top instruments but not as a typical process instrument. However, if fitted with a flow-cell they meet the criteria of this test method.
SCOPE
1.1 This test method covers the on-line and in-line determination of high-level turbidity in water that is greater than 1.0 turbidity units (TU) in municipal, industrial and environmental usage.
1.2 In principle, there are three basic applications for on-line measurement set ups. This first is the slipstream (bypass) sample technique. For the slipstream sample technique a portion of sample is transported out of the process and through the measurement apparatus. It is then either transported back to the process or to waste. The second is the in-line measurement where the sensor is brought directly into the process (see Fig. 8). The third basic method is for in-situ monitoring of sample waters. This principle is based on the insertion of a sensor into the sample itself as the sample is being processed. The in-situ use in this test method is intended for the monitoring of water during any step within a processing train, including immediately before or after the process itself.
1.3 This test method is applicable to the measurement of turbidities greater than 1.0 TU. The absolute range is dictated by the technology that is employed.
1.4 The upper end of the measurement range is left undefined because different technologies described in this test method can cover very different ranges of turbidity.
1.5 Many of the turbidity units and instrument designs covered in this test method are numerically equivalent in calibration when a common calibration standard is applied across those designs listed in Table 1. Measurement of a common calibration standard of a defined value will also produce equivalent results across these technologies. This test method prescribes the assignment of a determined turbidity values to the technology used to determine those values. Numerical equivalence to turbidity standards is observed between different technologies but is not expected across a common sample. Improved traceability beyond the scope of this test method may be practiced and would include the listing of the make and model number of the instrument used to determine the turbidity values.
1.5.1 In this test method, calibration standards are often defined in NTU values, but the other assigned turbidity units, such as those in Table 1 are equivalent. For example, a 1 NTU formazin standard is also a 1...
- Standard23 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Dissolved Ozone is useful in many industries for water sanitization, TOC reduction, food preservation, cleaning-in-place of food and beverage systems, and pyrogen destruction. It is often necessary to know how much ozone has entered the water, how much remains, and the degree to which it has been removed before process use.
5.2 Some applications require that contact time, DO3 concentration integrated over time, be calculated, to assure disinfection.
5.3 Continuous observation of trends in these measurements are needed for continuous quality monitoring and the measurement may be used for closed loop control of ozonation.
5.4 In many pure water applications and especially where water quality is regulated by the FDA or similar enforcement agencies, ozone removal must be complete before the water is used. This test method is useful for detecting and determining dissolved ozone levels in water at the trace level as well as at process concentrations where sanitization and chemical reactions occur.
SCOPE
1.1 This test method covers the on-line and in-line determination of dissolved ozone (DO3) in low conductivity water in the range from 0.001 mg/L to 5.0 mg/L DO3 and conductivity 3 is detected by correlating the response of a membrane-covered electrochemical sensor to the dissolved ozone concentration.
1.2 This test method provides a more convenient means for continuous measurement than the colorimetric methods typically used for grab sample measurements.
1.3 This test method has the advantage of high sensitivity as well as durability in the process environment and has few interferences.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard5 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Chlorine is added to potable water, waste water, and industrial water for a variety of purposes. Some of these purposes are:
5.1.1 To eliminate or reduce the growth of microorganisms in water,
5.1.2 To destroy or modify decomposable organic substances so as to reduce the biochemical oxygen demand of the water,
5.1.3 To eliminate or reduce taste, odors, and color in the water,
5.1.4 To separate grease in waste water by eliminating the protective colloidal effect of proteins present, and
5.1.5 To destroy or modify substances in the waste water that react directly by oxidation, such as ammonia, cyanates, cyanides, ferrous iron, nitrites, phenol, phosphorus, sulfides, sulfites, thiocyanates, and other oxidizable constituents.
5.2 It is important to avoid over-chlorination in order to minimize chemical consumption, meet restrictions specified by regulatory agencies, and minimize equipment degradation.
SCOPE
1.1 This practice provides a means of estimating the quantity of chlorine required to be added to a unit volume of water to accomplish a predetermined treatment objective or to completely react with all chlorine reactable substances in the water, or both.
1.2 Temperature, pH, and initial chlorine dosage are all variables in estimating the optimum chlorination practice. The effects of these variables can be evaluated using this practice.
1.3 Chlorine residual is determined using Test Method D1253.
1.4 This practice is applicable to all types of water in which the stated treatment objective can be evaluated or residual chlorine can be measured, or both.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For a specific hazard statement, see 7.5.1.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Even so-called high-purity water will contain contaminants. While not always present, these contaminants may contribute one or more of the following: dissolved active ionic substances such as calcium, magnesium, sodium, potassium, manganese, ammonium, bicarbonates, sulfates, nitrates, chloride and fluoride ions, ferric and ferrous ions, and silicates; dissolved organic substances such as pesticides, herbicides, plasticizers, styrene monomers, deionization resin material; and colloidal suspensions such as silica. While this test method facilitates the monitoring of these contaminants in high-purity water, in real time, with one instrument, this test method is not capable of identifying the various sources of residue contamination or detecting dissolved gases or suspended particles.
5.2 This test method is calibrated using weighed amounts of an artificial contaminant (potassium chloride). The density of potassium chloride is reasonably typical of contaminants found in high-purity water; however, the response of this test method is clearly based on a response to potassium chloride. The response to actual contaminants found in high-purity water may differ from the test method's calibration. This test method is not different from many other analytical test methods in this respect.
5.3 Together with other monitoring methods, this test method is useful for diagnosing sources of RAE in ultra-pure water systems. In particular, this test method can be used to detect leakages such as colloidal silica breakthrough from the effluent of a primary anion or mixed-bed deionizer. In addition, this test method has been used to measure the rinse-up time for new liquid filters and has been adapted for batch-type sampling (this adaptation is not described in this test method).
5.4 Obtaining an immediate indication of contamination in high-purity water has significance to those industries using high-purity water for manufacturing components; production can be halted immediate...
SCOPE
1.1 This test method covers the determination of dissolved organic and inorganic matter and colloidal material found in high-purity water used in the semiconductor, and related industries. This material is referred to as residue after evaporation (RAE). The range of the test method is from 0.001 μg/L (ppb) to 60 μg/L (ppb).
1.2 This test method uses a continuous, real time monitoring technique to measure the concentration of RAE. A pressurized sample of high-purity water is supplied to the test method's apparatus continuously through ultra-clean fittings and tubing. Contaminants from the atmosphere are therefore prevented from entering the sample. General information on the test method and a literature review on the continuous measurement of RAE has been published.2
1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazards statements, see Section 8.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard9 pagesEnglish language
SIGNIFICANCE AND USE
5.1 A rapid and routine procedure for determining biomass of the living microorganisms in cultures, waters, wastewaters, and in plankton and periphyton samples taken from surface waters is frequently of vital importance. However, classical techniques such as direct microscope counts, turbidity, organic chemical analyses, cell tagging, and plate counts are expensive, time-consuming, or tend to underestimate total numbers. In addition, some of these methods do not distinguish between living and nonliving cells.
5.2 This test method measures the concentration of cellular-ATP present in the sample. ATP is a constituent of all living cells, including bacteria, algae, protozoa, and fungi. Consequently, the presence of cellular-ATP is an indicator of total metabolically active microbial contamination in water. ATP is not associated with matter of non-biological origin.
5.3 The ATP (luciferin-luciferase) method is a rapid, sensitive determination of viable microbial biomass. ATP is the primary energy donor for life processes, does not exist in association with nonliving detrital material, and the amount of ATP per unit of biomass (expressed in weight) is relatively constant. (ATP per cell varies with species and physiological state of the organism.)
5.4 This test method can be used to:
5.4.1 Estimate viable microbial biomass in cultures and waters.
5.4.2 Estimate the amount of total viable biomass in plankton and periphyton samples.
5.4.3 Estimate the number of viable cells in a unispecies culture if the cATP content (or if the average amount of cATP) per cell is known.
5.4.4 Estimate and differentiate between zooplanktonic, phytoplanktonic, bacterial, and fungal cATP through size fractionation of water samples.
5.4.5 Measure the mortality rate of microorganisms in toxicity tests in entrainment studies, and in other situations where populations or assemblages of microorganisms are placed under stress.
5.5 This test method is similar to Test Metho...
SCOPE
1.1 This test method covers a protocol for capturing, extracting and quantifying the cellular adenosine triphosphate (cATP) content associated with microorganisms normally found in laboratory cultures and waters in plankton and periphyton samples from waters.
1.2 The ATP is measured using a bioluminescence enzyme assay, whereby light is generated in amounts proportional to the concentration of ATP in the samples. The light is produced and measured quantitatively as relative light units (RLU) which are converted by comparison with an ATP standard and computation to pg ATP/mL.
1.3 This method does not remove all known chemical interferences, known to either luminesce in the 530 nm ± 20 nm range, or to quench light emitted in that range. It should not be used to determine ATP concentrations in samples with dissolved organic compounds, heavy metals or >10 000 ppm total dissolved solids. Alternative methods have been developed for determining ATP concentrations in fluids samples likely to contain such interferences (Test Methods D7687 and E2694).
1.4 Knowledge of the concentration of ATP can be related to viable biomass or metabolic activity of microorganisms (Appendix X1).
1.5 This test method offers a high degree of sensitivity, rapidity, accuracy, and reproducibility.
1.6 The analyst should be aware that the precision statement pertains only to determinations in reagent water and not necessarily in the matrix being tested.
1.7 This test method is equally suitable for use in the laboratory or field.
1.8 The method normally detects cATP concentrations in the range of 0.1 pg cATP/mL (–1.0Log10 [pg cATP/mL]) to
4 000 000 pg cATP/mL (6.6 Log10 [pg cATP/mL]) in 50 mL water samples.
1.9 Providing interferences can be overcome, bioluminescence is a reliable and proven method for qualifying and quantifying ATP, although the method does not differentiate between ATP from different sources, for example, from...
- Standard10 pagesEnglish language
- Standard10 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Home reverse osmosis devices are typically used to remove salts and other impurities from drinking water at the point of use. They are usually operated at tap water line pressure, with water containing up to several hundred milligrams per litre of total dissolved solids. This practice permits measurement of the performance of home reverse osmosis devices using a standard set of conditions and is intended for short-term testing (less than 24 h). This practice can be used to determine changes that may have occurred in the operating characteristics of home reverse osmosis devices during use, but it is not intended to be used for system design. This practice does not necessarily determine the device’s performance when solutes other than sodium chloride are present. Use Practice D4516 and Test Methods D4194 to standardize actual field data to a standard set of conditions.
5.2 This practice is applicable for spiral-wound devices.
SCOPE
1.1 This practice covers determination of the operating characteristics of home reverse osmosis devices using standard test conditions. It does not necessarily determine the characteristics of the devices operating on natural waters.
1.2 This practice is applicable for spiral-wound devices.
1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard4 pagesEnglish language
- Standard4 pagesEnglish language
SIGNIFICANCE AND USE
5.1 Turbidity is undesirable in drinking water, plant effluent waters, water for food and beverage processing, and for a large number of other water-dependent manufacturing processes. Removal is often accomplished by coagulation, settling, and filtration. Measurement of turbidity provides a rapid means of process control for when, how, and to what extent the water must be treated to meet specifications.
5.2 This test method is suitable to turbidity such as that found in drinking water, process water, and high purity industrial water.
5.3 When reporting the measured result, appropriate units should also be reported. The units are reflective of the technology used to generate the result, and if necessary, provide more adequate comparison to historical data sets.
5.3.1 Table 1 describes technologies and reporting results (see also Refs (1-3)).6 Those technologies listed are appropriate for the range of measurement prescribed in this test method. Others may come available in the future. Fig. X5.1 provides a flow chart to aid in selection of the appropriate technology for low-level static turbidity applications.
5.3.2 If a design that falls outside of the criteria listed in Table 1 is used, the turbidity should be reported in turbidity units (TU) with a subscripted wavelength value to characterize the light source that was used.
SCOPE
1.1 This test method covers the static determination of turbidity in water (see 4.1).
1.2 This test method is applicable to the measurement of turbidities under 5.0 nephelometric turbidity units (NTU).
1.3 This test method was tested on municipal drinking water, ultra-pure water, and low turbidity samples. It is the users responsibility to ensure the validity of this test method for waters of untested matrices.
1.4 This test method uses calibration standards are defined in NTU values, but other assigned turbidity units are assumed to be equivalent.
1.5 This test method assigns traceable reporting units to the type of respective technology that was used to perform the measurement. Units are numerically equivalent with respect to the calibration standard. For example, a 1.0 NTU formazin standard is also equal to a 1.0 FNU standard, a 1.0 FNRU standard, and so forth.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Refer to the MSDSs for all chemicals used in this test method.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Standard15 pagesEnglish language
Frequently Asked Questions
D19 is a Technical Committee within ASTM International. It is named "Water" and is responsible for: The study of water, the promotion of knowledge thereof, and the standardization of terminology methods for: * Sampling and analysis of water, waterborne materials, and wastes, water- formed deposits and fluvial sediments, * Surface-water hydraulics and hydrologic measurements, * The determination of the performance of materials or products used to modify water characteristics, and * The determination of the corrosivity or deposit forming properties of water. The term "water" includes, but is not limited to, surface waters (rivers, lakes, artificial impoundments, runoff, etc.), groundwaters and springwaters, wastewaters (mine drainage, landfill leachate, brines, waters resulting from atmospheric precipitation and condensation (with the exception of acid deposition), process waters, potable waters, glacial melt waters, steam, water for subsurface injection and water discharges including waterborne materials and water-formed deposits. The work of the Committee will be coordinated with other ASTM Committees and other societies and organizations having mutual interests. This committee has published 1724 standards.
D19 develops ASTM standards in the area of Information technology. The scope of work includes: The study of water, the promotion of knowledge thereof, and the standardization of terminology methods for: * Sampling and analysis of water, waterborne materials, and wastes, water- formed deposits and fluvial sediments, * Surface-water hydraulics and hydrologic measurements, * The determination of the performance of materials or products used to modify water characteristics, and * The determination of the corrosivity or deposit forming properties of water. The term "water" includes, but is not limited to, surface waters (rivers, lakes, artificial impoundments, runoff, etc.), groundwaters and springwaters, wastewaters (mine drainage, landfill leachate, brines, waters resulting from atmospheric precipitation and condensation (with the exception of acid deposition), process waters, potable waters, glacial melt waters, steam, water for subsurface injection and water discharges including waterborne materials and water-formed deposits. The work of the Committee will be coordinated with other ASTM Committees and other societies and organizations having mutual interests. Currently, there are 1724 published standards from this technical committee.
ASTM is a standardization organization that develops and publishes standards to support industry, commerce, and regulatory requirements.
A Technical Committee (TC) in ASTM is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.