IEC 61643-332:2024 describes the theory of operation, principles for the selection and application of MOVs to be connected to power lines or telecommunication or signalling circuits, up to 1 000 V AC or 1 500 V DC. These SPCs are designed to protect apparatus or personnel, or both, from high transient voltages. This document applies to MOVs having two electrodes and voltage dependents elements with or without disconnectors. It does not apply to assemblies that include MOVs and their influence on the MOV's characteristics. This standard specifically discusses the zinc-oxide type of MOVs.

  • Standard
    63 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61643-332:2024 describes the theory of operation, principles for the selection and application of MOVs to be connected to power lines or telecommunication or signalling circuits, up to 1 000 V AC or 1 500 V DC. These SPCs are designed to protect apparatus or personnel, or both, from high transient voltages. This document applies to MOVs having two electrodes and voltage dependents elements with or without disconnectors. It does not apply to assemblies that include MOVs and their influence on the MOV's characteristics. This standard specifically discusses the zinc-oxide type of MOVs.

  • Standard
    63 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61643-332:2024 describes the theory of operation, principles for the selection and application of MOVs to be connected to power lines or telecommunication or signalling circuits, up to 1 000 V AC or 1 500 V DC. These SPCs are designed to protect apparatus or personnel, or both, from high transient voltages. This document applies to MOVs having two electrodes and voltage dependents elements with or without disconnectors. It does not apply to assemblies that include MOVs and their influence on the MOV's characteristics. This standard specifically discusses the zinc-oxide type of MOVs.

  • Standard
    127 pages
    English and French language
    sale 15% off

IEC 60393-4:2023 is applicable to single-turn rotary power potentiometers wire-wound technology. Enamelled, cemented, moulded, enclosed.
This specification is applicable to rotary potentiometers with nominal dissipation in excess of 10 W, the resistive element of which consists of a wire or a wound tape. All the potentiometers specified by this specification are slider-driven without reduction. Their stroke less than 360° is limited by stops.
This document specifies preferred ratings and characteristics and selects from IEC 60393-1, appropriate quality assessment procedures, tests and measuring methods. It provides general performance requirements for this type of potentiometer.
This document gives the minimum performance requirements and test severities. Annex A lists the letters and symbols used in the clauses of this document.
This edition includes the following significant technical changes with respect to the previous edition:
a) the document structure has been organized to follow new sectional specification structure decided in TC 40;
b) the information on the assessment level EZ and FZ (zero nonconforming) has been revised.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60393-4:2023 is applicable to single-turn rotary power potentiometers wire-wound technology. Enamelled, cemented, moulded, enclosed. This specification is applicable to rotary potentiometers with nominal dissipation in excess of 10 W, the resistive element of which consists of a wire or a wound tape. All the potentiometers specified by this specification are slider-driven without reduction. Their stroke less than 360° is limited by stops. This document specifies preferred ratings and characteristics and selects from IEC 60393-1, appropriate quality assessment procedures, tests and measuring methods. It provides general performance requirements for this type of potentiometer. This document gives the minimum performance requirements and test severities. Annex A lists the letters and symbols used in the clauses of this document. This edition includes the following significant technical changes with respect to the previous edition: a) the document structure has been organized to follow new sectional specification structure decided in TC 40; b) the information on the assessment level EZ and FZ (zero nonconforming) has been revised.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60393-4:2023 is applicable to single-turn rotary power potentiometers wire-wound technology. Enamelled, cemented, moulded, enclosed.
This specification is applicable to rotary potentiometers with nominal dissipation in excess of 10 W, the resistive element of which consists of a wire or a wound tape. All the potentiometers specified by this specification are slider-driven without reduction. Their stroke less than 360° is limited by stops.
This document specifies preferred ratings and characteristics and selects from IEC 60393-1, appropriate quality assessment procedures, tests and measuring methods. It provides general performance requirements for this type of potentiometer.
This document gives the minimum performance requirements and test severities. Annex A lists the letters and symbols used in the clauses of this document.
This edition includes the following significant technical changes with respect to the previous edition:
a) the document structure has been organized to follow new sectional specification structure decided in TC 40;
b) the information on the assessment level EZ and FZ (zero nonconforming) has been revised.

  • Standard
    63 pages
    English and French language
    sale 15% off

This part of IEC 60393 applies to rotary precision potentiometers for use in electronic equipment.
The object of this document is to prescribe preferred ratings and characteristics and to select
from IEC 60393-1, the appropriate quality assessment procedures, tests and measuring
methods and to give general performance requirements for this type of potentiometer.
This document gives the minimum performance requirements and test severities.

  • Standard
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60393 applies to rotary precision potentiometers for use in electronic equipment. The object of this standard is to prescribe preferred ratings and characteristics and to select from IEC 60393-1, the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of potentiometer. This standard gives the minimum performance requirements and test severities.

  • Standard
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60393-3:2023 applies to rotary precision potentiometers for use in electronic equipment. The object of this document is to prescribe preferred ratings and characteristics and to select from IEC 60393-1, the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of potentiometer. This document gives the minimum performance requirements and test severities.
This edition includes the following significant technical changes with respect to the previous edition:
a) revised all parts of the document based on the ISO/IEC Directives, Part 2:2018 (eighth edition) and harmonized with other similar kinds of documents;
b) the document structure has been organized to follow new sectional specification structure decided in TC 40;
c) revision of the information on the assessment level EZ (zero nonconforming).

  • Standard
    69 pages
    English and French language
    sale 15% off

This part of IEC 61051 is a sectional specification and is applicable to metal oxide varistors with symmetrical voltage-current characteristics for use in electronic equipment connected to any AC or DC supply system.
These varistors are designed to protect electronic and other sensitive equipment from high transient surges. Varistors under the scope of this sectional specification are not intended to give primary protection against lightning surges.
These varistors have metallic connections and are intended to be mounted as through hole component or directly on to printed boards.
The object of this document is to prescribe preferred ratings and characteristics and to select from IEC 61051-1 the appropriate quality assessment procedures, tests and measuring methods, and to give general performance requirements for this type of varistors. Test severities and requirements prescribed in detail specifications referring to this sectional specification should be of equal or higher performance level, because lower performance levels are not permitted.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61051 is a sectional specification and is applicable to metal oxide varistors with symmetrical voltage-current characteristics for use in electronic equipment connected to any AC or DC supply system. These varistors are designed to protect electronic and other sensitive equipment from high transient surges. Varistors under the scope of this sectional specification are not intended to give primary protection against lightning surges. These varistors have metallic connections and are intended to be mounted as through hole component or directly on to printed boards. The object of this document is to prescribe preferred ratings and characteristics and to select from IEC 61051-1 the appropriate quality assessment procedures, tests and measuring methods, and to give general performance requirements for this type of varistors. Test severities and requirements prescribed in detail specifications referring to this sectional specification should be of equal or higher performance level, because lower performance levels are not permitted.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61051-2:2021 is a sectional specification and is applicable to metal oxide varistors with symmetrical voltage-current characteristics for use in electronic equipment connected to any AC or DC supply system.
These varistors are designed to protect electronic and other sensitive equipment from high transient surges. Varistors under the scope of this sectional specification are not intended to give primary protection against lightning surges.
These varistors have metallic connections and are intended to be mounted as through hole component or directly on to printed boards.
The object of this document is to prescribe preferred ratings and characteristics and to select from IEC 61051-1 the appropriate quality assessment procedures, tests and measuring methods, and to give general performance requirements for this type of varistors.
This edition includes the following significant technical changes with respect to the previous edition:  
revision for the structure in accordance with ISO/IEC Directives, Part 2) to the extent practicable, and for harmonizing with IEC 61051-1:2018;
Annex X has been added for comparison with the previous edition;
two lists of preferred voltage ratings for disk type and SMD type varistors have been added;
permissible numbers of non-conforming items have been set to zero (zero fault) in the test schedule in 8.4.3.

  • Standard
    42 pages
    English and French language
    sale 15% off

EN-IEC 61643-331 is a test specification for metal oxide varistors (MOV), which are usedfor applications up to 1 000 V AC or 1 500 V DC in power lines, or telecommunication, orsignalling circuits. They are designed to protect apparatus or personnel, or both, from hightransient voltages.This document applies to MOVs having two electrodes and hybrid surge protectioncomponents. This document also does not apply to mountings and their effect on the MOV’scharacteristics. Characteristics given apply solely to the MOV mounted only in the waysdescribed for the tests.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61643-331:2020 is available as IEC 61643-331:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61643-331:2020 is a test specification for metal oxide varistors (MOV), which are used for applications up to 1 000 V AC or 1 500 V DC in power lines, or telecommunication, or signalling circuits. They are designed to protect apparatus or personnel, or both, from high transient voltages. This document applies to MOVs having two electrodes and hybrid surge protection components. This document also does not apply to mountings and their effect on the MOV’s characteristics. Characteristics given apply solely to the MOV mounted only in the ways described for the tests. This third edition cancels and replaces the second edition published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- a Varistor MCOV rating assurance test;
- an energy rating test (2ms);
- revised Dielectric strength and insulation resistance tests.

  • Standard
    42 pages
    English language
    sale 15% off
  • Standard
    85 pages
    English language
    sale 15% off
  • Standard
    89 pages
    English and French language
    sale 15% off

IEC 60393-5:2015 applies to single-turn rotary low-power wirewound and non-wirewound potentiometers, with a rated dissipation less than to 10 W. These potentiometers are primarily intended for use in electronic equipment. This part of IEC 60393 prescribes preferred ratings and characteristics and selects from IEC 60393-1, appropriate quality assessment procedures, tests and measuring methods. It provides general performance requirements for this type of potentiometer. This standard gives the minimum performance requirements and test severities. This edition includes the following significant technical changes with respect to the previous edition: a) revision of the information on the assessment level EZ and FZ (zero nonconforming); b) complete editorial revision.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60393-2:2015 applies to lead-screw actuated and rotary preset potentiometers, wirewound and non-wirewound for use in electronic equipment. These potentiometers are primarily intended for use in circuits for trimming purposes which require infrequent adjustments. This part of IEC 60393 prescribes preferred ratings and characteristics and selects from IEC 60393-1 the appropriate quality assessment procedures, tests and measuring methods. It provides general performance requirements for this type of potentiometer. This standard gives the minimum performance requirements and test severities. This edition includes the following significant technical changes with respect to the previous edition: a) revision of the information on the assessment level EZ and FZ (zero nonconforming); b) complete editorial revision.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60393-6:2015 applies to surface mount preset potentiometers for use in electronic equipment. This part of IEC 60393 prescribes preferred ratings and characteristics and selects from IEC 60393-1, the appropriate quality assessment procedures, tests and measuring methods, and it gives general performance requirements for this type of potentiometers. This standard gives the minimum performance requirements and test severities. This edition includes the following significant technical changes with respect to the previous edition: a) revision of the information on the assessment level EZ (zero nonconforming); b) complete editorial revision.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61643-331:2017 is a test specification for metal oxide varistors (MOV), which are used for applications up to 1 000 V AC or 1 500 V DC in power line, or telecommunication, or signalling circuits. They are designed to protect apparatus or personnel, or both, from high transient voltages. This specification applies to MOVs having two electrodes and hybrid overvoltage protection components. This specification also does not apply to mountings and their effect on the MOV’s characteristics. Characteristics given apply solely to the MOV mounted only in the ways described for the tests. This second edition cancels and replaces the first edition published in 2003. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) Update of the nominal varistor voltage test method;
b) Addition of thermally protected varistors – component symbol and test methods;
c) Addition of nominal discharge current – test methods;
d) Addition of voltage ratings for disc types (Table 1);
e) Addition of test currents for clamping voltage of disc types (Table 2);
f) Addition of typical voltage ratings of SMD types (Table 3); and
g) Addition of Limited current and temporary overvoltage tests for thermally protected varistors.
Keywords: metal oxide varistors (MOV), high transient voltages.

  • Standard
    41 pages
    English language
    sale 15% off
  • Standard
    82 pages
    English and French language
    sale 15% off

This part of IEC 60393 applies to single-turn rotary low-power wirewound and non-wirewound
potentiometers, with a rated dissipation less than to 10 W. These potentiometers are primarily
intended for use in electronic equipment.
This part of IEC 60393 prescribes preferred ratings and characteristics and selects from
IEC 60393-1, appropriate quality assessment procedures, tests and measuring methods. It
provides general performance requirements for this type of potentiometer.
This standard gives the minimum performance requirements and test severities.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60393 applies to lead-screw actuated and rotary preset potentiometers,
wirewound and non-wirewound for use in electronic equipment. These potentiometers are
primarily intended for use in circuits for trimming purposes which require infrequent
adjustments.
This part of IEC 60393 prescribes preferred ratings and characteristics and selects from
IEC 60393-1 the appropriate quality assessment procedures, tests and measuring methods. It
provides general performance requirements for this type of potentiometer.
This standard gives the minimum performance requirements and test severities.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60393 applies to surface mount preset potentiometers for use in electronic
equipment.
This part of IEC 60393 prescribes preferred ratings and characteristics and selects from
IEC 60393-1, the appropriate quality assessment procedures, tests and measuring methods,
and it gives general performance requirements for this type of potentiometers.
This standard gives the minimum performance requirements and test severities.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60393-6:2015 applies to surface mount preset potentiometers for use in electronic equipment. This part of IEC 60393 prescribes preferred ratings and characteristics and selects from IEC 60393-1, the appropriate quality assessment procedures, tests and measuring methods, and it gives general performance requirements for this type of potentiometers. This standard gives the minimum performance requirements and test severities. This edition includes the following significant technical changes with respect to the previous edition:
a) revision of the information on the assessment level EZ (zero nonconforming);
b) complete editorial revision.
This publication is to be read in conjunction with IEC 60393-1:2008.

  • Standard
    57 pages
    English and French language
    sale 15% off

IEC 60393-2:2015 applies to lead-screw actuated and rotary preset potentiometers, wirewound and non-wirewound for use in electronic equipment. These potentiometers are primarily intended for use in circuits for trimming purposes which require infrequent adjustments. This part of IEC 60393 prescribes preferred ratings and characteristics and selects from IEC 60393-1 the appropriate quality assessment procedures, tests and measuring methods. It provides general performance requirements for this type of potentiometer. This standard gives the minimum performance requirements and test severities. This edition includes the following significant technical changes with respect to the previous edition:
a) revision of the information on the assessment level EZ and FZ (zero nonconforming);
b) complete editorial revision.
This publication is to be read in conjunction with IEC 60393-1:2008.

  • Standard
    53 pages
    English and French language
    sale 15% off

IEC 60393-5:2015 applies to single-turn rotary low-power wirewound and non-wirewound potentiometers, with a rated dissipation less than to 10 W. These potentiometers are primarily intended for use in electronic equipment. This part of IEC 60393 prescribes preferred ratings and characteristics and selects from IEC 60393-1, appropriate quality assessment procedures, tests and measuring methods. It provides general performance requirements for this type of potentiometer. This standard gives the minimum performance requirements and test severities. This edition includes the following significant technical changes with respect to the previous edition:
a) revision of the information on the assessment level EZ and FZ (zero nonconforming);
b) complete editorial revision.
This publication is to be read in conjunction with IEC 60393-1:2008.

  • Standard
    65 pages
    English and French language
    sale 15% off

IEC 60393-1:2008(E) is applicable to all types of resistive potentiometers, including lead-screw actuated types, presets, multi-turn units, etc. to be used in electronic equipment. It establishes standard terms, inspection procedures and methods of test for use in sectional and detail specifications of electronic components for quality assessment or any other purpose. It has been mainly written, and the test methods described, to conform to the widely used single-turn rotary potentiometer with an operating shaft . This edition contains the following significant technical changes with respect to the previous edition: implementation of Annex H which replaces Section 3 of the previous edition. It also includes minor revisions related to tables, figures and references.

  • Standard
    108 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60393 is applicable to all types of resistive potentiometers, including leadscrew actuated types, presets, multi-turn units, etc. to be used in electronic equipment. It establishes standard terms, inspection procedures and methods of test for use in sectional and detail specifications of electronic components for quality assessment or any other purpose. It has been mainly written, and the test methods described, to conform to the widely used single-turn rotary potentiometer with an operating shaft. For other types of potentiometers: - the angle of rotation may be several turns; - the reference to an operating shaft shall apply to any other actuating device; - the angular rotation shall be taken to mean mechanical travel of the actuating device; - a value for force shall be prescribed instead of a value for torque if the actuating device moves in a linear instead of a rotary manner. These alternative prescriptions will be found in the sectional or detail specification. When a component is constructed as a variable resistor, i.e. as a two-terminal device, the detail specification shall prescribe the modifications required in the standard tests.

  • Standard
    108 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC/TR 62453-61:2009(E), which is a technical report, explains the guidelines and rules for the implementation of a Device Type Manager (DTM) with regard to the user interface and its functions. These guidelines and rules are part of the FDT specification and are intended to ensure that all users are provided with clear and consistent user interface functions and features across DTM devices in a system.

  • Technical report
    33 pages
    English language
    sale 15% off

IEC 60393-1:2008 is applicable to all types of resistive potentiometers, including lead- screw actuated types, presets, multi-turn units, etc., to be used in electronic equipment. It establishes standard terms, inspection procedures and methods of test for use in sectional and detail specifications of electronic components for quality assessment or any other purpose. It has been mainly written, and the test methods described, to conform to the widely used single-turn rotary potentiometer with an operating shaft. This edition contains the following significant technical changes with respect to the previous edition: implementation of Annex H which replaces Section 3 of the previous edition. It also includes minor revisions related to tables, figures and references.

  • Standard
    104 pages
    English language
    sale 15% off
  • Standard
    215 pages
    English and French language
    sale 15% off

Details the test specifications for metal oxide varistors (MOV), which are used for applications up to 1000 V a.c. or 1500 V d.c. in power line, or telecommunication, or signalling circuits. The MOVs are designed to protect apparatus or personnel, or both from high transient voltages. Does not deal with hybrid devices. Does not apply also to mountings and their effect on the MOVs characteristics.

  • Standard
    33 pages
    English and French language
    sale 15% off

prescribes preferred ratings and characteristics and selects appropriate quality assessment procedures, tests and measuring methods from IEC 60393-1 and gives general performance requirements for this type of potentiometer.

  • Standard
    26 pages
    English language
    sale 15% off

Gives requirements additional to those in IEC 60243-1 for the determination of the electric strength of solid insulating materials under direct voltage stress.

  • Standard
    13 pages
    English and French language
    sale 15% off

Gives test methods for the determination of the short-time electric strength of solid insulating materials at power frequencies between 48 Hz and 62 Hz. It does not consider the testing of liquids and gases.

  • Standard
    47 pages
    English and French language
    sale 15% off

IEC 61643-331:2017E) is a test specification for metal oxide varistors (MOV), which are used for applications up to 1 000 V AC or 1 500 V DC in power line, or telecommunication, or signalling circuits. They are designed to protect apparatus or personnel, or both, from high transient voltages. This specification applies to MOVs having two electrodes and hybrid overvoltage protection components. This specification also does not apply to mountings and their effect on the MOV’s characteristics. Characteristics given apply solely to the MOV mounted only in the ways described for the tests. This second edition cancels and replaces the first edition published in 2003. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) Update of the nominal varistor voltage test method;
b) Addition of thermally protected varistors – component symbol and test methods;
c) Addition of nominal discharge current – test methods;
d) Addition of voltage ratings for disc types (Table 1);
e) Addition of test currents for clamping voltage of disc types (Table 2);
f) Addition of typical voltage ratings of SMD types (Table 3); and
g) Addition of Limited current and temporary overvoltage tests for thermally protected varistors.
Keywords: metal oxide varistors (MOV), high transient voltages.

  • Standard
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Details the test specifications for metal oxide varistors (MOV), which are used for applications up to 1000 V a.c. or 1500 V d.c. in power line, or telecommunication, or signalling circuits. The MOVs are designed to protect apparatus or personnel, or both from high transient voltages. Does not deal with hybrid devices. Does not apply also to mountings and their effect on the MOVs characteristics.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

A Blank Detail Specification is a supplementary document to the Sectional Specification and contains requirements for style, layout and minimum content of Detail Specifications

  • Standard
    14 pages
    English language
    sale 15% off

Supersedes CECC 41 101 Issue 2 * CECC WG 4B work handled by SR 40

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61753-091-2:2012 contains the minimum test and measurement requirements and severities which a fibre optic circulator as specified by IEC 62077 should satisfy in order to be categorized as meeting the requirements of circulators used in controlled environments as specified in IEC 61753-1. Keywords: fibre optic circulator

  • Standard
    24 pages
    English and French language
    sale 15% off

Reviews the position of CISPR limits for the protection of telecommunications from interference from ISM equipment, clarifies the roles of the CCIR and the CISPR in their collaboration in studies on the limits required for this purpose, summarizes the various proposals for methods of specifying limits and derives from these a recommended method which will meet the objectives of CISPR and CCIR. Deals only with radiation which occurs outside the bands designated by ITU for ISM use and does not include consideration of data-processing equipment.

  • Standard
    28 pages
    English and French language
    sale 15% off