IEC 60079-29-0:2025 specifies general requirements, test methods and acceptance criteria that apply to flammable, oxygen and toxic gas detection equipment intended to detect gases and vapours and to provide an indication, alarm or other output function for personnel or property protection in industrial and commercial applications.
This document applies to the following gas detection equipment:
– Gas detection equipment Type "FL" intended for the detection of flammable gases:
• Type FL-Group I, in mines susceptible to firedamp;
• Type FL-Group II, in locations other than mines susceptible to firedamp; and
• Type FL-OP, open path gas detection equipment for flammable gases.
– Gas detection equipment Type "O2" intended for the detection of Oxygen:
• Type O2-DE, detection of oxygen deficiency or oxygen enrichment; and
• Type O2-IN, inertisation as measuring function for explosion protection.
– Gas detection equipment Type "TX" intended for the detection of toxic gases:
• Type TX-SM, detection in areas for safety monitoring applications and typically using alarm signalling;
• Type TX-HM, occupational exposure measurement in the region of occupational exposure limit values; and
• Type TX-OP, open path gas detection equipment for toxic gases.
This document is not applicable to equipment:
– used for medical applications;
– used only in laboratories for analysis or measurement;
– used only for process monitoring or control purposes (such as a gas analyser);
– used in the domestic environment;
– used in environmental air pollution monitoring;
– used for flue gas analysis;
– used for sampling systems external to the gas detection equipment;
– with samplers and concentrators such as sorbents or paper tape having an irreversible indication;
– consisting of a passive optical receiver without a dedicated optical source;
– equipment within the scope of IEC 60335-2-40 and IEC 60335-2-89.
This first edition of IEC 60079-29-0 cancels and replaces the second edition of 60079-29-1 published in 2016 and its Amendment 1:2020, and the first edition of IEC 60079-29-4 published in 2009. In addition, IEC 60079-29-0 Type TX-SM cancels and replaces Type SM of the first edition of IEC 62990-1.
- Standard88 pagesEnglish languagesale 15% off
- Standard93 pagesFrench languagesale 15% off
- Standard181 pagesEnglish and French languagesale 15% off
IEC 60079-28:2025 specifies additional requirements for Ex Equipment, Ex associated equipment or Ex Components containing optical systems emitting optical radiation, which is exposed to explosive atmospheres. These additional requirements are applicable for all equipment groups and all Equipment Protection Levels (EPL).
This document contains requirements for optical radiation in the wavelength range from 380 nm to 10 µm. It covers the following ignition mechanisms:
• Optical radiation is absorbed by surfaces or particles, causing them to heat up, and under certain circumstances this might allow them to attain a temperature which will ignite a surrounding explosive atmosphere.
• In rare special cases, direct laser induced breakdown of the gas at the focus of a strong beam, producing plasma and a shock wave both eventually acting as ignition source. These processes can be supported by a solid material close to the breakdown point.
• Annex A provides guidance when considering ignition mechanisms that influence the hazard of optics in explosive atmospheres.
This document applies to
a) laser equipment; and
b) optical fibre equipment; and
c) any optical system that converts light into convergent beams with focal points within the hazardous area only.
This document does not apply to:
d) laser equipment for EPL Mb, Gb, Gc, Db or Dc applications which complies with Class 1 limits in accordance with IEC 60825-1; or
e) Single or multiple optical fibre cables not part of optical fibre equipment if the cables:
1) comply with the relevant industrial standards for optical fibre cables, along with additional protective means, for example robust cabling, conduit or raceway (for EPL Gb, Db, Mb, Gc or Dc); or
2) comply with the relevant industrial standards for optical fibre cables (for EPL Gc or Dc); or
f) Optical radiation sources as defined in i) to iii) above where the optical radiation is fully contained in an enclosure complying with one of the following Types of Protection suitable for the EPL, or the minimum ingress protection rating specified:
1) flameproof "d" enclosures (IEC 60079-1); or
2) pressurized "p" enclosures (IEC 60079-2); or
3) restricted breathing "nR" enclosure (IEC 60079-15); or
4) dust protection "t" enclosures" (IEC 60079-31); or
5) an enclosure that provides a minimum ingress protection of IP 6X and where no internal absorbers are to be expected and complying with "Tests of enclosures" in IEC 60079-0.
This document does not cover ignition by ultraviolet radiation and by absorption of the radiation in the explosive mixture itself. Explosive absorbers or absorbers that contain their own oxidizer as well as catalytic absorbers are also outside the scope of this document.
This document supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of this document takes precedence.
This third edition cancels and replaces the second edition published in 2015. This edition constitutes a technical revision
- Standard30 pagesEnglish languagesale 15% off
- Standard32 pagesFrench languagesale 15% off
- Standard62 pagesEnglish and French languagesale 15% off
IEC 60079-19:2025 applies to service facilities and covers only those factors related to overhaul, repair or reclamation of Ex Equipment specifically designed for hazardous areas, where the hazard is caused by explosive atmospheres. Ex Equipment can be overhauled, repaired or reclaimed to mitigate deficiencies identified during operation, inspection and maintenance.
It does not include:
• advice on cable and wiring systems which can require a renewal when the equipment is re-installed;
• Repair or overhaul of Type of Protection “m”;
• Repair or overhaul of Ex Components;
• Requirements for manufacturers who overhaul and repair equipment which they have manufactured
This fifth edition cancels and replaces the fourth edition published in 2019. This edition constitutes a technical revision.
Users of this document are advised that interpretation sheets clarifying the interpretation of this document can be published. Interpretation sheets are available from the IEC webstore and can be found in the “history” tab of the page for each document.
The significance of changes between IEC 60079-19, Edition 5 (2025) and IEC 60079-19, Edition 4 (2019) are as listed in the foreword of this standard.
- Standard92 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60079-18:2025 gives the specific requirements for the construction, testing and marking of electrical Ex Equipment, parts of electrical Ex Equipment and Ex Components with the Type of Protection encapsulation "m" (hereinafter referred to as "m" Equipment) intended for use in explosive gas atmospheres or explosive dust atmospheres. For Levels of Protection "mb" and "mc", this document applies where the rated voltage does not exceed 11 kV ACRMS or DC. For Level of Protection "ma", this document applies where the rated voltage does not exceed 1 kV ACRMS or DC. This document does not take account of any hazard due to an emission of flammable or toxic gas from the dust. This document supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of this document takes precedence. This fifth edition cancels and replaces the fourth edition published in 2014 and Amendment 1:2017. This edition constitutes a technical revision. This International Standard is to be used in conjunction with IEC 60079-0, Explosive atmospheres - Part 0: Equipment - General requirements. Users of this document are advised that interpretation sheets clarifying the interpretation of this document can be published. Interpretation sheets are available from the IEC webstore and can be found in the "history" tab of the page for each document. Please see the foreword to this document for the list of significant technical changes with respect to the previous edition.
- Standard41 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60079-45:2025 is intended to enhance the safety of personnel by providing minimum requirements for electrical ignition systems for spark-ignited reciprocating internal combustion engines, parts of which provide Equipment Protection Level (EPL) Gc.
This document provides minimum construction and test requirements, in addition to manufacturer installation and maintenance recommendations, for the safe operation of ignition systems and components for spark-ignited reciprocating internal combustion engines providing EPL Gc for equipment Group IIB+H2, IIB or IIA. These requirements apply to systems rated for normal operation with secondary voltages less than or equal to 60 kV.
This document applies only to the ignition systems or the individual ignition system components used on reciprocating internal combustion engines that are stationary when in operation and mobile machinery where the internal combustion engine can be potential source of ignition. Applications addressed by the scope of this document include but are not limited to gas compressors, electric power generators, forklift trucks, and pumps.
This document does not apply to:
a) Engine ignition systems that utilize a breaker point or magneto type ignition systems as these would not be suitable for use in a hazardous area.
b) Road vehicles.
c) Low voltage parts and electrical installation that are not included in the ignition system, such as various sensors and thermocouples, throttle actuator(s), fuel control valve(s), human machine interface (HMI), respective harness and wiring and all the other items that might belong to the integrated control system besides the ignition system.
This document supplements and modifies the general requirements of IEC 60079-0 and the requirements of ISO/IEC 80079-41. Where a requirement of this document conflicts with IEC 60079 0 or ISO/IEC 80079-41, the requirement of this document takes precedence.
- Standard47 pagesEnglish languagesale 10% offe-Library read for1 day
- Draft10 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60079-18:2025 gives the specific requirements for the construction, testing and marking of electrical Ex Equipment, parts of electrical Ex Equipment and Ex Components with the Type of Protection encapsulation "m" (hereinafter referred to as "m" Equipment) intended for use in explosive gas atmospheres or explosive dust atmospheres. For Levels of Protection "mb" and "mc", this document applies where the rated voltage does not exceed 11 kV ACRMS or DC. For Level of Protection "ma", this document applies where the rated voltage does not exceed 1 kV ACRMS or DC. This document does not take account of any hazard due to an emission of flammable or toxic gas from the dust. This document supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of this document takes precedence. This fifth edition cancels and replaces the fourth edition published in 2014 and Amendment 1:2017. This edition constitutes a technical revision. This International Standard is to be used in conjunction with IEC 60079-0, Explosive atmospheres - Part 0: Equipment - General requirements. Users of this document are advised that interpretation sheets clarifying the interpretation of this document can be published. Interpretation sheets are available from the IEC webstore and can be found in the "history" tab of the page for each document. Please see the foreword to this document for the list of significant technical changes with respect to the previous edition.
- Standard41 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60079-45:2025 is intended to enhance the safety of personnel by providing minimum requirements for electrical ignition systems for spark-ignited reciprocating internal combustion engines, parts of which provide Equipment Protection Level (EPL) Gc. This document provides minimum construction and test requirements, in addition to manufacturer installation and maintenance recommendations, for the safe operation of ignition systems and components for spark-ignited reciprocating internal combustion engines providing EPL Gc for equipment Group IIB+H2, IIB or IIA. These requirements apply to systems rated for normal operation with secondary voltages less than or equal to 60 kV. This document applies only to the ignition systems or the individual ignition system components used on reciprocating internal combustion engines that are stationary when in operation and mobile machinery where the internal combustion engine can be potential source of ignition. Applications addressed by the scope of this document include but are not limited to gas compressors, electric power generators, forklift trucks, and pumps. This document does not apply to: a) Engine ignition systems that utilize a breaker point or magneto type ignition systems as these would not be suitable for use in a hazardous area. b) Road vehicles. c) Low voltage parts and electrical installation that are not included in the ignition system, such as various sensors and thermocouples, throttle actuator(s), fuel control valve(s), human machine interface (HMI), respective harness and wiring and all the other items that might belong to the integrated control system besides the ignition system. This document supplements and modifies the general requirements of IEC 60079-0 and the requirements of ISO/IEC 80079-41. Where a requirement of this document conflicts with IEC 60079 0 or ISO/IEC 80079-41, the requirement of this document takes precedence.
- Standard47 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard7 pagesEnglish languagesale 15% off
- Standard8 pagesFrench languagesale 15% off
- Standard15 pagesEnglish and French languagesale 15% off
IEC 60079-25:2020 contains the specific requirements for design, construction and assessment of intrinsically safe systems, Type of Protection “i”, intended for use, as a whole or in part, in locations in which the use of Group I, II or III Ex Equipment is required. This document supplements and modifies the general requirements of IEC 60079-0 and the intrinsic safety standard IEC 60079-11. Where a requirement of this standard conflicts with a requirement of IEC 60079-0 or IEC 60079-11, the requirement of this standard takes precedence. The installation requirements of Group II or Group III systems designed in accordance with this standard are specified in IEC 60079-14. This third edition cancels and replaces the second edition published in 2010 and constitutes a technical revision. The contents of the corrigendum 1 of October 2020 and corrigendum 2 of November 2022 have been included in this copy.
- Standard123 pagesEnglish languagesale 15% off
- Standard117 pagesEnglish and French languagesale 15% off
This document is applicable to the safe management and operation (3.1.2) of and work activity
(3.4.1) on, with, or near electrical installations operating at voltage levels from, and including,
extra-low voltage up to and including high voltage.
This latter term includes those levels commonly referred to as medium and extra-high voltage.
These electrical installations are designed for the generation, transmission, conversion,
distribution and use of electrical power. Some of these electrical installations are permanent
and fixed, such as a distribution installation in a factory or office complex. Others are temporary,
such as on construction sites, and some are mobile or capable of being moved either whilst
energized or whilst not energized nor charged, examples are electrically driven excavating
machines in quarries or open-cast coal sites.
This document sets out the requirements for the safe management and operation (3.1.2) of and
work activity (3.4.1) on, with, or near these electrical installations. The requirements apply to
all operational, working and maintenance procedures. They apply to all non-electrical work
(3.4.3) such as building work near to overhead lines or underground cables as well as electrical
work (3.4.2), when there is a risk (3.1.3) of electrical danger (3.1.5).
This document does not apply to ordinary persons (3.2.7) when using installations and
equipment, provided that the installations and equipment comply with relevant standards and
are designed and installed for use by ordinary persons (3.2.7).
This document has not been developed specifically to apply to the electrical installations listed
below. However, if there are no other rules or procedures, the principles of this document could
be applied to them:
– on any aircraft and hovercraft moving under its own power, (international aviation laws can
apply);
– on any sea going ship moving under its own power, or under the direction of the master,
(international marine laws can apply);
– electronic telecommunications and information systems;
– electronic instrumentation, control and automation systems;
– at coal or other mines;
– on off-shore installations (international marine laws can apply);
– on vehicles;
– on electric traction systems;
– on experimental electrical research work.
- Technical specification90 pagesEnglish languagesale 10% offe-Library read for1 day
- Technical specification89 pagesEnglish languagesale 15% off
IEC/IEEE 60079-30-1:2025 is available as IEC/IEEE 60079-30-1:2025 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC/IEEE 60079-30-1:2025 specifies general and testing requirements for electrical resistance trace heaters for application in explosive atmospheres with the exclusion of those for Equipment Protection Levels (EPL) Ga, Da, Ma and Mb equipment. This document covers trace heaters that comprise either factory or field (worksite) assembled units, and which can be series trace heaters, parallel trace heaters, trace heater pads, or trace heater panels that have been assembled and/or terminated in accordance with the manufacturer's instructions.
This document also includes requirements for termination assemblies and control methods used with trace heating systems. The explosive atmospheres referred to in this document are those defined in IEC 60079-10-1 and IEC 60079-10-2.
Annex F and Annex G outline the application of this document for those users applying the Division method of area classification
This second edition of IEC/IEEE 60079-30-1 cancels and replaces the first edition of IEC/IEEE 60079-30-1 published in 2015. This edition constitutes a technical revision.
The significant technical changes with respect to the previous edition can be found n the foreword of this publication.
- Standard167 pagesEnglish languagesale 15% off
IEC/IEEE 60079-30-2:2025 is available as IEC/IEEE 60079-30-2:2025 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC/IEEE 60079-30-2:2025 provides guidance for the application of electrical resistance trace heating systems in areas where explosive atmospheres can be present, with the exclusion of those classified as requiring Equipment Protection Level (EPL) Ga or Da (traditional relationship to Zone 0 and Zone 20 respectively). This document also provides guidance for explosive atmospheres incorporating the Division method of area classification that can be applied by some users of this document.
This document provides recommendations for the design, installation, maintenance and repair of trace heating systems including associated control and monitoring equipment. It does not cover devices that operate by induction heating, skin effect heating or direct pipeline heating, nor those intended for stress relieving.
This second edition of IEC/IEEE 60079-30-2 cancels and replaces the first edition of IEC/IEEE 60079-30-2 published in 2015.
This edition includes the following significant technical changes with respect to the previous edition:
a) a general review and updating of the first edition;
b) the addition of Annex I – Other applications of trace heating in explosive atmospheres.
The significance of changes between IEC/IEEE 60079-30-2, Edition 1.0 (2015) and IEC/IEEE 60079-30-2, Edition 2.0 (this document) can be found on the foreword of this document.
- Standard150 pagesEnglish languagesale 15% off
IEC 60079-19:2025 applies to service facilities and covers only those factors related to overhaul, repair or reclamation of Ex Equipment specifically designed for hazardous areas, where the hazard is caused by explosive atmospheres. Ex Equipment can be overhauled, repaired or reclaimed to mitigate deficiencies identified during operation, inspection and maintenance. It does not include: • advice on cable and wiring systems which can require a renewal when the equipment is re-installed; • Repair or overhaul of Type of Protection “m”; • Repair or overhaul of Ex Components; • Requirements for manufacturers who overhaul and repair equipment which they have manufactured This fifth edition cancels and replaces the fourth edition published in 2019. This edition constitutes a technical revision. Users of this document are advised that interpretation sheets clarifying the interpretation of this document can be published. Interpretation sheets are available from the IEC webstore and can be found in the “history” tab of the page for each document. The significance of changes between IEC 60079-19, Edition 5 (2025) and IEC 60079-19, Edition 4 (2019) are as listed in the foreword of this standard.
- Standard92 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard2 pagesEnglish languagesale 15% off
- Standard2 pagesEnglish languagesale 15% off
IEC 60079-45:2025 is intended to enhance the safety of personnel by providing minimum requirements for electrical ignition systems for spark-ignited reciprocating internal combustion engines, parts of which provide Equipment Protection Level (EPL) Gc.
This document provides minimum construction and test requirements, in addition to manufacturer installation and maintenance recommendations, for the safe operation of ignition systems and components for spark-ignited reciprocating internal combustion engines providing EPL Gc for equipment Group IIB+H2, IIB or IIA. These requirements apply to systems rated for normal operation with secondary voltages less than or equal to 60 kV.
This document applies only to the ignition systems or the individual ignition system components used on reciprocating internal combustion engines that are stationary when in operation and mobile machinery where the internal combustion engine can be potential source of ignition. Applications addressed by the scope of this document include but are not limited to gas compressors, electric power generators, forklift trucks, and pumps.
This document does not apply to:
a) Engine ignition systems that utilize a breaker point or magneto type ignition systems as these would not be suitable for use in a hazardous area.
b) Road vehicles.
c) Low voltage parts and electrical installation that are not included in the ignition system, such as various sensors and thermocouples, throttle actuator(s), fuel control valve(s), human machine interface (HMI), respective harness and wiring and all the other items that might belong to the integrated control system besides the ignition system.
This document supplements and modifies the general requirements of IEC 60079-0 and the requirements of ISO/IEC 80079-41. Where a requirement of this document conflicts with IEC 60079 0 or ISO/IEC 80079-41, the requirement of this document takes precedence.
- Standard43 pagesEnglish languagesale 15% off
- Standard46 pagesFrench languagesale 15% off
- Standard89 pagesEnglish and French languagesale 15% off
IEC TS 63527:2025 is applicable to the safe management and operation of and work activity on, with, or near electrical installations operating at voltage levels from and including extra-low voltage up to and including high voltage.
This latter term includes those levels commonly referred to as medium and extra-high voltage.
These electrical installations are designed for the generation, transmission, conversion, distribution and use of electrical power. Some of these electrical installations are permanent and fixed, such as a distribution installation in a factory or office complex, others are temporary, such as on construction sites, and others are mobile or capable of being moved either whilst energized or whilst not energized nor charged. Examples are electrically driven excavating machines in quarries or open-cast coal sites.
This document sets out the requirements for the safe management and operation of and work activity on, with, or near these electrical installations. The requirements apply to all operational, working and maintenance procedures. They apply to all non-electrical work such as building work near to overhead lines or underground cables as well as electrical work , when there is a risk of electrical danger.
This document does not apply to ordinary persons when using installations and equipment, provided that the installations and equipment comply with relevant standards and are designed and installed for use by ordinary persons.
This document has not been developed specifically to apply to the electrical installations listed below. However, if there are no other rules or procedures, the principles of this document could be applied to them:
– on any aircraft and hovercraft moving under its own power, (international aviation laws can apply);
– on any sea going ship moving under its own power, or under the direction of the master, (international marine laws can apply);
– electronic telecommunications and information systems;
– electronic instrumentation, control and automation systems;
– at coal or other mines;
– on off-shore installations (international marine laws can apply);
– on vehicles;
– on electric traction systems;
–on experimental electrical research work.
- Technical specification90 pagesEnglish languagesale 10% offe-Library read for1 day
- Technical specification89 pagesEnglish languagesale 15% off
IEC 60079-19:2025 applies to service facilities and covers only those factors related to overhaul, repair or reclamation of Ex Equipment specifically designed for hazardous areas, where the hazard is caused by explosive atmospheres. Ex Equipment can be overhauled, repaired or reclaimed to mitigate deficiencies identified during operation, inspection and maintenance.
It does not include:
• advice on cable and wiring systems which can require a renewal when the equipment is re-installed;
• Repair or overhaul of Type of Protection “m”;
• Repair or overhaul of Ex Components;
• Requirements for manufacturers who overhaul and repair equipment which they have manufactured
This fifth edition cancels and replaces the fourth edition published in 2019. This edition constitutes a technical revision.
Users of this document are advised that interpretation sheets clarifying the interpretation of this document can be published. Interpretation sheets are available from the IEC webstore and can be found in the “history” tab of the page for each document.
The significance of changes between IEC 60079-19, Edition 5 (2025) and IEC 60079-19, Edition 4 (2019) are as listed in the foreword of this standard.
- Standard87 pagesEnglish languagesale 15% off
- Standard94 pagesFrench languagesale 15% off
- Standard181 pagesEnglish and French languagesale 15% off
IEC 60079-18:2025 gives the specific requirements for the construction, testing and marking of electrical Ex Equipment, parts of electrical Ex Equipment and Ex Components with the Type of Protection encapsulation "m" (hereinafter referred to as "m" Equipment) intended for use in explosive gas atmospheres or explosive dust atmospheres. For Levels of Protection "mb" and "mc", this document applies where the rated voltage does not exceed 11 kV ACRMS or DC. For Level of Protection "ma", this document applies where the rated voltage does not exceed 1 kV ACRMS or DC. This document does not take account of any hazard due to an emission of flammable or toxic gas from the dust. This document supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of this document takes precedence. This fifth edition cancels and replaces the fourth edition published in 2014 and Amendment 1:2017. This edition constitutes a technical revision. This International Standard is to be used in conjunction with IEC 60079-0, Explosive atmospheres - Part 0: Equipment - General requirements. Users of this document are advised that interpretation sheets clarifying the interpretation of this document can be published. Interpretation sheets are available from the IEC webstore and can be found in the "history" tab of the page for each document. Please see the foreword to this document for the list of significant technical changes with respect to the previous edition.
- Standard74 pagesEnglish and French languagesale 15% off
This part of IEC 60079 specifies the construction and testing of intrinsically safe apparatus intended for use in an explosive atmosphere, and for associated apparatus which is intended for connection to intrinsically safe circuits which enter such atmospheres.
This Type of Protection is applicable to electrical equipment in which the electrical circuits themselves are incapable of causing ignition of a surrounding explosive atmosphere. This includes electrical equipment which contains circuits that are intrinsically safe only under certain conditions, for example under battery supply with mains supply removed.
This standard is also applicable to electrical equipment or parts of electrical equipment located outside the explosive atmosphere or protected by another Type of Protection listed in IEC 60079-0, where the intrinsic safety of the electrical circuits in the explosive atmosphere may depend upon the design and construction of such electrical equipment or parts of such electrical equipment. The electrical circuits exposed to the explosive atmosphere are assessed for use in such an atmosphere by applying this standard.
This standard applies to sensors connected to intrinsically safe circuits but does not apply to the protection of catalytic elements for Group IIC or Group IIB + H2.
The requirements for intrinsically safe systems are provided in IEC 60079-25.
This standard supplements and modifies the general requirements of IEC 60079-0, except as indicated in Table 1. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of this standard takes precedence.
Unless otherwise stated, the requirements in this standard are applicable to both intrinsically safe apparatus and associated apparatus, and the generic term "apparatus" is used throughout the standard.
As this standard applies only to electrical equipment, the term "equipment" used in the standard always means “electrical equipment”.
This standard applies to apparatus for use under the atmospheric conditions of IEC 60079-0 with additional requirements for for use at lower atmospheric pressures in the range from 60 kPa (0,6 bar), up to 110 kPa (1,1 bar).
[...]
- Standard222 pagesEnglish languagesale 10% offe-Library read for1 day
1.1 This document specifies the electrical requirements for the design of automatic electrostatic application systems for liquid coating materials which can be ignited in an atomised state, used within a temperature range from 5 °C to 40 °C.
This document considers automatic electrostatic application systems for processing ignitable liquid coating materials, where the conductivity of the complete system is limited up to 50 nS/cm. Together with additional measures like e.g. potential separation systems, these requirements can also be applied to ignitable liquid coating materials, where the conductivity of the complete system is limited up to 2 000 μS/cm.
Ignition hazards related to the generated explosive atmosphere and the protection of persons against electric shock are considered.
1.2 This document specifies
- requirements for an interface to machinery according to EN 16985:2018,
- additional requirements for machinery covered by EN 1953:2025 and EN 12621:2025.
1.3 This document also specifies requirements for a safe operation of electrostatic application systems, including the electrical installation. The requirements consider both the processing of coating materials and the cleaning and purge processes.
1.4 This document applies to three types of spraying systems; see 5.1.1.
Spraying systems are classified as equipment of group II, category 2G (for intended use in zone 1 or zone 2) or category 3G (for intended use in zone 2).
Only electrostatic spraying systems operating with a d.c. sinusoidal ripple of not more than 10 % of the r.m.s. value are considered.
1.5 For electrostatic application systems used in food and pharmaceutical industry, additional requirements may apply.
1.6 This document does not apply to
- potential separation systems;
- selection, installation and application of other electrical and non-electrical equipment in areas with explosion hazard, see EN 60079-14:2014 and EN 16985:2018;
- quality assurance systems for electrostatic spraying equipment (see EN ISO/IEC 80079-34:2020, ZB.11).
- Standard55 pagesEnglish languagesale 10% offe-Library read for1 day
No scope available
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
NEXT ACTION: UNDER BT CONSULTATION SOON (finalization EN with revised Annex Z)
HAS CONSULTANT PUB ASSESSMENT BY 2020-09-24 -- non compliant assessment received
20200325: consultant assessment missing and Annex ZZ was not circulated at FV; document blocked until such a time as this can be resolved
- Amendment10 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60079:2024 contains the specific requirements for the design of electrical systems, selection, installation and the required initial inspection of electrical installations of Ex Equipment in, or associated with, explosive atmospheres including requirements for documentation and personnel competency.
These requirements are in addition to the requirements for installations in non-hazardous areas.
This document applies to all electrical Ex Equipment including fixed, transportable, portable and personal, and installations, permanent or temporary.
This document does not apply to:
• electrical installations in mines susceptible to firedamp;
• inherently explosive situations and dust from explosives or pyrophoric substances (for example explosives manufacturing and processing);
• rooms used for medical purposes;
• electrical installations in areas where the hazard is due to flammable mist; and
• installation of non-electrical Ex Equipment (unless being part of an equipment assembly according IEC TS 60079-46).
No account is taken in this document of the toxic hazards that are associated with flammable gases, liquids and dusts in concentrations that are usually very much less than the lower flammable limit. In locations where personnel could be exposed to potentially toxic concentrations of flammable material, appropriate precautions are necessary. Such precautions are outside the scope of this document.
This sixth edition cancels and replaces the fifth edition published in 2013. This edition constitutes a technical revision. Edition 6 is a major restructure and introduces a number of technical changes from the previous edition (2013), see Table 1 of the foreword for detailed information.
- Standard149 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard gives requirements and the corresponding test/assessment methods applicable to leak detection kits (leak detector) based on the measurement of pressure change. Leak detection kits are intended to be used with double skin, underground or above ground, pressurized or non-pressurized, tanks or pipework designed for water polluting liquids/fluids. The kits are usually composed of:
- measuring device;
- evaluation device;
- alarm device;
- pressure generator;
- pressure relief device;
- liquid stop device;
- condensate trap.
- Standard53 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard gives requirements and the corresponding test/assessment methods applicable to leak detection kits based on the detection of the presence of liquid and/or vapour in interstitial spaces, leakage containments or monitoring wells. The kits are usually composed by:
- sensing device(s);
- evaluation device;
- alarm device.
- Standard29 pagesEnglish languagesale 10% offe-Library read for1 day
This standard gives requirements and the corresponding test/assessment methods applicable to leak detection lining kits and leak detection jacket kits. Leak detection lining kits and leak detection jackets kits intended to be used as post-installed to create an interstitial space or leakage containment in single skin underground or above ground, non-pressurized, tanks designed for water polluting liquids. The kit has to be used only in conjunction with leak detection kits covered by prEN 13160-2 to prEN 13160-4.
- Standard41 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the technical parameters of track circuits associated with the interference current emissions limits for RST in the context of interoperability defined in the form of Frequency Management in ERA/ERTMS/033281 v4.0. The limits for compatibility between rolling stock and track circuits addressed in this document allow provision for known interference phenomena linked to traction power supply including associated protection (over voltage, short-circuit current and basic transient effects like in-rush current and power cut-off), and other known sources of interference.
This document is intended to be used to assess compliance of track circuits and other forms of train detection systems using the rails as part of their detection principles, in the context of the European Directive on the interoperability of the trans-European railway system and the associated technical specification for interoperability relating to the control-command and signalling track-side subsystems.
The document describes technical parameters to consider for achieving the compatibility of the track circuit with the emissions limits defined in the frequency management for rolling stock (ERA/ERTMS/033281 v4.0). These parameters are structured and allocated according to their basic references as follows:
- technical track circuit parameters;
- train based parameters;
- track based parameters;
- environmental and other parameters including EMC.
Each parameter is defined by a short general description, the definition of the requirement, the relation to other standards and a procedure to show the fulfilment of the requirement as far as necessary. An overview of the safety relevance of each parameter is given - in the context of this document - in a separate table.
This document is applicable to track circuits on all lines, including non-electrified lines. However, for track circuits intended to be installed only on non-electrified lines, some parameters can be disapplied.
- Standard82 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60079 specifies the construction and testing of intrinsically safe apparatus intended for use in an explosive atmosphere, and for associated apparatus which is intended for connection to intrinsically safe circuits which enter such atmospheres. This Type of Protection is applicable to electrical equipment in which the electrical circuits themselves are incapable of causing ignition of a surrounding explosive atmosphere. This includes electrical equipment which contains circuits that are intrinsically safe only under certain conditions, for example under battery supply with mains supply removed. This standard is also applicable to electrical equipment or parts of electrical equipment located outside the explosive atmosphere or protected by another Type of Protection listed in IEC 60079-0, where the intrinsic safety of the electrical circuits in the explosive atmosphere may depend upon the design and construction of such electrical equipment or parts of such electrical equipment. The electrical circuits exposed to the explosive atmosphere are assessed for use in such an atmosphere by applying this standard. This standard applies to sensors connected to intrinsically safe circuits but does not apply to the protection of catalytic elements for Group IIC or Group IIB + H2. The requirements for intrinsically safe systems are provided in IEC 60079-25. This standard supplements and modifies the general requirements of IEC 60079-0, except as indicated in Table 1. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of this standard takes precedence. Unless otherwise stated, the requirements in this standard are applicable to both intrinsically safe apparatus and associated apparatus, and the generic term "apparatus" is used throughout the standard. As this standard applies only to electrical equipment, the term "equipment" used in the standard always means “electrical equipment”. This standard applies to apparatus for use under the atmospheric conditions of IEC 60079-0 with additional requirements for for use at lower atmospheric pressures in the range from 60 kPa (0,6 bar), up to 110 kPa (1,1 bar). [...]
- Standard222 pagesEnglish languagesale 10% offe-Library read for1 day
No scope available
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
1.1 This document specifies the constructional requirements for fans constructed to Group II G (of explosion groups IIA, IIB and hydrogen) categories 1, 2 and 3, and Group II D categories 2 and 3, intended for use in explosive atmospheres.
NOTE 1 Operation conditions for the different categories of fans used in this document are defined in Clause 4.
1.3 This document specifies requirements for design, construction, testing and marking of complete fan units intended for use in potentially explosive atmospheres in air containing gas, vapour, mist and/or dusts. Such atmospheres can exist inside (the conveyed atmosphere (flammable or not)), outside, or inside and outside of the fan.
This document covers mechanical equipment, in particular fans. The “type of protection” as specified in EN ISO 80079 37:2016 is constructional safety.
1.4 This document is applicable to fans working in ambient atmospheres and with normal atmospheric conditions at the inlet, having
— absolute pressures ranging from 0,8 bar to 1,1 bar,
— and temperatures ranging from −20 °C to +60 °C,
— and maximum volume fraction of 21 % oxygen content,
— and an aerodynamic energy increase of less than 25 kJ/kg.
NOTE 1 25 kJ/kg is equivalent to 30 kPa at inlet density of 1,2 kg/m3.
This document can also be helpful for the design, construction, testing and marking of fans intended for use in atmospheres outside the validity range stated above or in cases where other material pairings need to be used. In this case, the ignition risk assessment, ignition protection provided, additional testing (if necessary), manufacturer's marking, technical documentation and instructions to the user, clearly demonstrate and indicate the equipment's suitability for the conditions the fan can encounter.
NOTE 2 Temperatures below −20 °C can be considered. Material suitability can require specific evaluation for these temperatures. With lower temperature the explosion pressure increases, which leads to increased test pressures (see A.3) and can require specific testing. Although the standard atmospheric conditions in EN ISO 80079 36:2016 give a temperature range for the atmosphere of −20 °C to +60 °C the normal ambient temperature range for the equipment is −20 °C to +40 °C unless otherwise specified and marked.
1.5 This document does not apply to:
— group I fans (fans for mining);
— explosion group IIC (other than hydrogen);
— category 1D fans;
— cooling fans or impellers on rotating electrical machines;
— cooling fans or impellers on internal combustion engines, vehicles or electric motors.
NOTE 3 Measures for category 1D fans are given in EN 1127 1:2019.
NOTE 4 Measures for explosion group IIC (other than hydrogen) are given in EN 1127 1:2019.
NOTE 5 Measures for explosion group I are given in EN ISO/IEC 80079 38:2016 and EN 1127 2:2014.
- Standard60 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements for flame arresters that prevent flame transmission when explosive gas-air or vapour-air mixtures are present. It establishes uniform principles for the classification, basic construction and information for use, including the marking of flame arresters, and specifies test methods to verify the safety requirements and determine safe limits of use. This document is applicable to pressures ranging from 80 kPa to 160 kPa and temperatures ranging from -20 °C to +200 °C. This document does not apply to the following: - external safety-related measurement and control equipment that might be required to keep the operational conditions within the established safe limits; - flame arresters used for explosive mixtures of vapours and gases, which tend to self-decompose (for example, acetylene) or which are chemically unstable; - flame arresters used for carbon disulfide, due to its special properties; - flame arresters whose intended use is for mixtures other than gas-air or vapour-air mixtures (for example, higher oxygen-nitrogen ratio, chlorine as oxidant); - flame arrester test procedures for reciprocating internal combustion engines; - fast acting valves, extinguishing systems and other explosion isolating systems; - Flame arresters used in gas detectors (those being covered for example, by IEC 60079‑29‑1 and IEC 62990‑1). This edition cancels and replaces ISO 16852:2016, which has been technically revised. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to ISO 16852:2016: a) adaptation of the relevant IEC TC 31 requirements on standards; b) modification of the upper limit of the temperature range from 150 °C to 200 °C under the condition that T0 shall be not larger than 80 % of the auto ignition temperature of the gas-air-mixture; c) change of the term "explosion group" to "equipment group" due to editorial requirements in IEC/TC 31; d) clarification of the conditions and requirements for flame arresters whose intended operating conditions are outside the atmospheric conditions in 7.3.4 and 7.3.5; e) clarification of the requirements on the information for use in Clause 12 f) concerning the burn time; f) addition of a permission to the construction requirements both in 7.1 and 14.1 to substitute visual inspection by performing a flow test; g) addition of a flow chart for the evaluation of test results as Annex D
- Standard75 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies terms and definitions (vocabulary) to be used in suitable standards dealing with equipment and protective systems intended for use in potentially explosive atmospheres within the scope of Directive 2014/34/EU.
NOTE Terms and definitions avoid misunderstandings that are important in relation to the essential health and safety requirements of Directive 2014/34/EU.
- Standard38 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the technical parameters of track circuits associated with the interference current emissions limits for RST in the context of interoperability defined in the form of Frequency Management in ERA/ERTMS/033281 v4.0. The limits for compatibility between rolling stock and track circuits addressed in this document allow provision for known interference phenomena linked to traction power supply including associated protection (over voltage, short-circuit current and basic transient effects like in-rush current and power cut-off), and other known sources of interference. This document is intended to be used to assess compliance of track circuits and other forms of train detection systems using the rails as part of their detection principles, in the context of the European Directive on the interoperability of the trans-European railway system and the associated technical specification for interoperability relating to the control-command and signalling track-side subsystems. The document describes technical parameters to consider for achieving the compatibility of the track circuit with the emissions limits defined in the frequency management for rolling stock (ERA/ERTMS/033281 v4.0). These parameters are structured and allocated according to their basic references as follows: - technical track circuit parameters; - train based parameters; - track based parameters; - environmental and other parameters including EMC. Each parameter is defined by a short general description, the definition of the requirement, the relation to other standards and a procedure to show the fulfilment of the requirement as far as necessary. An overview of the safety relevance of each parameter is given - in the context of this document - in a separate table. This document is applicable to track circuits on all lines, including non-electrified lines. However, for track circuits intended to be installed only on non-electrified lines, some parameters can be disapplied.
- Standard82 pagesEnglish languagesale 10% offe-Library read for1 day
This standard gives requirements and the corresponding test/assessment methods applicable to leak detection lining kits and leak detection jacket kits. Leak detection lining kits and leak detection jackets kits intended to be used as post-installed to create an interstitial space or leakage containment in single skin underground or above ground, non-pressurized, tanks designed for water polluting liquids. The kit has to be used only in conjunction with leak detection kits covered by prEN 13160-2 to prEN 13160-4.
- Standard41 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard gives requirements and the corresponding test/assessment methods applicable to leak detection kits based on the detection of the presence of liquid and/or vapour in interstitial spaces, leakage containments or monitoring wells. The kits are usually composed by:
- sensing device(s);
- evaluation device;
- alarm device.
- Standard29 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard gives requirements and the corresponding test/assessment methods applicable to leak detection kits (leak detector) based on the measurement of pressure change. Leak detection kits are intended to be used with double skin, underground or above ground, pressurized or non-pressurized, tanks or pipework designed for water polluting liquids/fluids. The kits are usually composed of:
- measuring device;
- evaluation device;
- alarm device;
- pressure generator;
- pressure relief device;
- liquid stop device;
- condensate trap.
- Standard53 pagesEnglish languagesale 10% offe-Library read for1 day
IEC TR 61328:2024 provides information for the selection of conductor stringing, earthing and bonding equipment used for the installation of bare and insulated overhead distribution conductors, as well as overhead transmission conductors and overhead earth wires.
Procedures are given for installation and maintenance of distribution and transmission conductors. A discussion of electric hazards is provided as well as relevant earthing and bonding techniques.
- Technical report59 pagesEnglish languagesale 15% off
IEC 60079:2024 contains the specific requirements for the design of electrical systems, selection, installation and the required initial inspection of electrical installations of Ex Equipment in, or associated with, explosive atmospheres including requirements for documentation and personnel competency. These requirements are in addition to the requirements for installations in non-hazardous areas. This document applies to all electrical Ex Equipment including fixed, transportable, portable and personal, and installations, permanent or temporary. This document does not apply to: • electrical installations in mines susceptible to firedamp; • inherently explosive situations and dust from explosives or pyrophoric substances (for example explosives manufacturing and processing); • rooms used for medical purposes; • electrical installations in areas where the hazard is due to flammable mist; and • installation of non-electrical Ex Equipment (unless being part of an equipment assembly according IEC TS 60079-46). No account is taken in this document of the toxic hazards that are associated with flammable gases, liquids and dusts in concentrations that are usually very much less than the lower flammable limit. In locations where personnel could be exposed to potentially toxic concentrations of flammable material, appropriate precautions are necessary. Such precautions are outside the scope of this document. This sixth edition cancels and replaces the fifth edition published in 2013. This edition constitutes a technical revision. Edition 6 is a major restructure and introduces a number of technical changes from the previous edition (2013), see Table 1 of the foreword for detailed information.
- Standard149 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies terms and definitions (vocabulary) to be used in suitable standards dealing with equipment and protective systems intended for use in potentially explosive atmospheres within the scope of Directive 2014/34/EU.
NOTE Terms and definitions avoid misunderstandings that are important in relation to the essential health and safety requirements of Directive 2014/34/EU.
- Standard38 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60079:2024 contains the specific requirements for the design of electrical systems, selection, installation and the required initial inspection of electrical installations of Ex Equipment in, or associated with, explosive atmospheres including requirements for documentation and personnel competency.
These requirements are in addition to the requirements for installations in non-hazardous areas.
This document applies to all electrical Ex Equipment including fixed, transportable, portable and personal, and installations, permanent or temporary.
This document does not apply to:
• electrical installations in mines susceptible to firedamp;
• inherently explosive situations and dust from explosives or pyrophoric substances (for example explosives manufacturing and processing);
• rooms used for medical purposes;
• electrical installations in areas where the hazard is due to flammable mist; and
• installation of non-electrical Ex Equipment (unless being part of an equipment assembly according IEC TS 60079-46).
No account is taken in this document of the toxic hazards that are associated with flammable gases, liquids and dusts in concentrations that are usually very much less than the lower flammable limit. In locations where personnel could be exposed to potentially toxic concentrations of flammable material, appropriate precautions are necessary. Such precautions are outside the scope of this document.
This sixth edition cancels and replaces the fifth edition published in 2013. This edition constitutes a technical revision. Edition 6 is a major restructure and introduces a number of technical changes from the previous edition (2013), see Table 1 of the foreword for detailed information.
- Standard300 pagesEnglish and French languagesale 15% off
- Standard2 pagesEnglish languagesale 15% off
IEC 60079-26:2021 specifies requirements for construction, testing and marking for Ex Equipment that contains parts of the equipment with different Equipment Protection Levels (EPLs) and a separation element. This equipment is mounted across a boundary where different EPLs are required, for example between different gas hazardous areas, dust hazardous areas or gas hazardous areas adjacent to dust hazardous areas.
Separation elements are considered for both electrical and non-electrical equipment. If mechanical energy can be transformed into a potential ignition source, additionally an ignition hazard assessment in accordance with ISO 80079-36 is performed and appropriate measures are undertaken.
This document also specifies requirements for the combination of two Types of Protection, each with EPL Gb, to achieve EPL Ga.
This document supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of this document takes precedence. This fourth edition cancels and replaces the third edition and constitutes a technical revision.
Please see the IEC 60079-26:2020 foreword for a description of the main changes with respect to the previous edition.
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard2 pagesEnglish languagesale 15% off
- Standard2 pagesEnglish languagesale 15% off
- Standard2 pagesEnglish languagesale 15% off
Creating an amendment on European level to mirror the IEC interpretation sheet of IEC 60079-28:2015/ISH1:2019 which is still active at IEC.
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60079-31:2022 is available as IEC 60079-31:2022 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60079-31:2022 is applicable to equipment protected by enclosure and surface temperature limitation for use in explosive dust atmospheres. It specifies requirements for design, construction and testing of Ex Equipment and Ex Components. This document supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of this document takes precedence. This document does not apply to dusts of explosives, which do not require atmospheric oxygen for combustion, or to pyrophoric substances. This document does not apply to Ex Equipment or Ex Components intended for use in underground parts of mines as well as those parts of surface installations of such mines endangered by firedamp and/or combustible dust. This document does not take account of any risk due to an emission of flammable or toxic gas from the dust. This third edition cancels and replaces the second edition published in 2013. This edition constitutes a technical revision. Main significant changes from the previous edition are:
1) Document has been restructured from edition 2
2) Fault current rating of interrupting contacts in clauses 4.3.1 and 4.4.1, major change type C1
3) Cells and batteries in clauses 4.3.5.1 and 4.4.5.1, major change type C2
4) Overload or malfunction condition for the determination of temperature class for "tb" converter fed rotating electric machines, major change type C3
5) Additional requirements for entry devices with dust ignition protection by enclosure "t", major change type C4
Information about the background of ‘Major Technical Changes’
C1 – Ex Equipment having Level of Protection "ta" shall be rated for connection to a circuit with a prospective short circuit current of not greater than 1.5 kA. For Ex Equipment having Level of Protection "tb" or "tc" which is intended for mains connection and intended to interrupt fault current above 10kA, the equipment shall have a rated maximum short circuit withstand current, be tested according to 6.1.1.1, and be marked according to Clause 7.
C2 – For Ex Equipment having Level of Protection "ta" which contains a cell or battery, only a sealed cell or battery shall be used. For Ex Equipment having Level of Protection "tb" and "tc" where there are sparking contacts or hot surfaces, and which contains a cell or battery, only a sealed cell or battery shall be used.
C3 – Table 2 now includes malfunction conditions for temperature class determination of Level of Protection "tb" converter-fed electric machines.
C4 – Annex A added for entry devices with Type of Protection "t" including cable transit devices.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
Creating an amendment on European level to mirror the IEC interpretation sheet of IEC 60079-0:2017/ISH1:2019 and IEC 60079-0:2017/ISH2:2019 which are both active at IEC.
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day