SC 65A - Safety aspects
- Abstract
To prepare international standards regarding the safety and related aspects impacting safety of systems used in industrial process measurement, control and automation.
- Slovenian
Aspects systèmes
Préparer des normes applicables aux aspects génériques des systèmes utilisés pour la mesure et la conduite des processus industriels : conditions de fonctionnement (CEM comprise), méthodologie d'évaluation des systèmes, sécurité fonctionnelle, etc. Fonction Horizontale de Sécurité Sécurité fonctionnelle des systèmes électriques/électroniques/électroniques programmables (comprenant les logiciels concernant la sécurité).
IEC 61512-1:2026 applies to systems, specifications, and their use for implementing batch and related procedure-oriented manufacturing controls in the process industries. This document establishes a reference model framework for procedure-oriented control, defines terms to help explain the model relationships and usage, and describes general criteria for evaluating conformance. This follows the principle of separation between recipe procedural elements and equipment procedural elements enabling operations to define recipes without the need of changes in equipment procedures. This second edition cancels and replaces the first edition published in 1997. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Models and text are modified to provide more detail and clarity. Key clarifications are: 1) Two types of equipment modules are defined: generic and recipe-aware. All recipe-aware equipment modules contain procedural control and can be used as phases in the recipe. 2) Execution of all procedural control contained directly in units is part of the Unit Supervision activity. 3) The relationships between types of recipes, recipe components, and equipment control are more fully described and illustrated. 4) Entity relationship diagrams have been replaced with more intuitive UML instance diagrams, except for the equipment entity model. 5) The transition diagram for the procedural states example has been updated with a more intuitive and complete UML state diagram. 6) References to other standards in the series and to IEC 62264 are included to provide direction for further clarification of selected topics. 7) Activity names are capitalised to help prevent confusion with similar terms, such as their underlying functions. b) Previous Clauses 4 through 6 (now Clauses 4 through 8) were rearranged to provide a clearer top-down organisation of the document. Key changes are: 1) Removing the lower levels of the physical (role-based equipment) model (see 4.4.2) to eliminate redundancy because their groupings are defined by the associated functionality in the equipment entity model and are not meaningful for batch control without those associations. 2) Describing equipment control and the equipment entity model immediately after the physical (role-based equipment) model and describing each level as completely as possible without excessive use of forward references (see 4.4.3). 3) Combining the descriptions of basic, procedural, and coordination control with their usage in each type of equipment entity, providing a single consolidated discussion of each type of control (see Clause 5) 4) Additional considerations to support application of the models have been grouped in Clause 7 to clarify their supporting relationship to the core models. c) Clause 9 was added to define completeness, compliance, and conformance in relation to this document. d) Annex B was added to provide a more expansive procedural state reference model. The model found in Clause 7 can be considered a collapsed version of this more general model. e) Annex C was added to clarify a number of points concerning the models, their application, and the new Clause 9 on conformance and compliance. f) Annex E was added to more fully describe the changes in this update to IEC 61512-1:1997.
- Standard132 pagesEnglish languagee-Library read for
IEC 61326-2-7:2025 specifies the EMC test requirements for process automation equipment using at least one Ethernet APL (Ethernet ADVANCED PHYSICAL LAYER) compliant port according IEC TS 63444. The type of equipment covered by this document includes INFRASTRUCTURE DEVICES such as switches as well as measurement and control devices. This document provides requirements for the EMC test setups of the APL interface for devices intended for use in process control and process measurement.
The other functions of the equipment remain covered by other parts of the IEC 61326 series.
NOTE Ethernet-APL uses IEEE Std. 802.3 2022 Ethernet Physical Layer 10BASE-T1L, suitable to be used for full-duplex communication over a single balanced pair of conductors.
The test levels are based on the intended environment as stated in the product’s specification or user documentation and selected appropriately from IEC 61326-1.
- Standard39 pagesEnglish languagesale 15% off
- Standard91 pagesEnglish and French languagesale 15% off
IEC 61326-2-6:2025 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of IN VITRO DIAGNOSTIC MEDICAL ELECTRICAL EQUIPMENT (IVD MEE). This part of IEC 61326 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of IVD MEE in the presence of electromagnetic disturbances and to electromagnetic disturbances emitted by IVD MEE. BASIC SAFETY with regard to electromagnetic disturbances is applicable to all IVD MEE. NOTE 1 Performance with respect to electromagnetic disturbances other than ESSENTIAL PERFORMANCE is the subject of IEC 61326-1:2020 NOTE 2 IT equipment can be a part of an IVD MEE, if it is required to maintain BASIC SAFETY or ESSENTIAL PERFORMANCE. This edition includes the following significant technical changes with respect to the previous edition: - Update of the document with respect to test levels and documentation.
- Standard36 pagesEnglish languagee-Library read for
IEC TR 61508-3-3:2025 makes a proposal as to which topics to consider and which methods and techniques to use when designing object-oriented software to ensure suitable quality for use in functional safety applications.
Object-oriented languages are perceived as "state-of-the-art" nowadays. Such languages seem to be excluded from use by several statements in IEC 61508-3. However there are additions in some tables such as in IEC 61508-3:2010, Table B.1, where notes are added under which their use might be justified. Such exceptions that would allow, for example, dynamic objects, name the main concerns such as memory allocation and predictable timing issues and guide the user to safe use of object-oriented languages. These considerations are taken up in this document to specify methods and techniques that allow the reduction of systematic faults to the levels required by the respective systematic capabilities.
This document is not intended to replace any part of IEC 61508-3. Rules that exist in IEC 61508‑3 are valid here as well and are not repeated, including rules that concern:
• the software life cycle,
• involvement of the assessor,
• modularization,
• principle of information hiding,
• proving and conventional testing,
• basic aspects of documentation,
• low coupling and high cohesion,
• responsibilities and training of people,
• operational experience as described in IEC 61508-4 and IEC 61508-7
This TR is a supplement to the IEC 61508 standard series. It has to be read in conjunction with IEC 61508-3 and proposes a way how the use of object-oriented software in safety relevant applications can be justified.
- Technical report52 pagesEnglish languagesale 15% off
IEC 61326-2-6:2025 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of IN VITRO DIAGNOSTIC MEDICAL ELECTRICAL EQUIPMENT (IVD MEE). This part of IEC 61326 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of IVD MEE in the presence of electromagnetic disturbances and to electromagnetic disturbances emitted by IVD MEE.
BASIC SAFETY with regard to electromagnetic disturbances is applicable to all IVD MEE.
NOTE 1 Performance with respect to electromagnetic disturbances other than ESSENTIAL PERFORMANCE is the subject of IEC 61326-1:2020
NOTE 2 IT equipment can be a part of an IVD MEE, if it is required to maintain BASIC SAFETY or ESSENTIAL PERFORMANCE.
This edition includes the following significant technical changes with respect to the previous edition:
- Update of the document with respect to test levels and documentation.
- Standard70 pagesEnglish and French languagesale 15% off
IEC 61010-2-201:2024 supplements or modifies the corresponding clauses in IEC 61010-1 so as to convert that publication into the IEC standard: Particular requirements for control equipment. This document is to be used in conjunction with IEC 61010-1:2010, and IEC 61010 1:2010/AMD1:2016. Where a particular subclause of IEC 61010-1 is not mentioned in this document, that subclause applies as far as is reasonable. Where this document states "addition", "modification", "replacement", or "deletion", the relevant requirement, test specification or note in IEC 61010 1 should be adapted accordingly.
This edition includes the following significant technical changes with respect to the previous edition:
a) 1.1.1: the related equipment included in the Scope has been clarified;
b) 4.3.2.101: the optical fibre module has been deleted;
c) 5.4.3: equipment installation has been clarified;
d) 6.7.1.1: revision of the figure representing insulation between separate circuits has been included;
e) 6.7.101: the subclause relating to insulation for FIELD WIRING TERMINALS of OVERVOLTAGE CATEGORY ll with a nominal voltage up to 1 000 V has been deleted;
f) 6.7.1.101: a new subclause relating to insulation for SELV/PELV CIRCUITS has been included;
g) 6.8.3: specification of voltage tester has been added;
h) 6.9.3: an additional exception relating to colour coding has been included;
i) 6.9.101: a new subclause relating to wiring for secondary circuits e.g. SELV/PELV has been included;
j) 8.2.2.101: additional requirements for glass displays have been included;
k) 8.3: the subclause relating to the drop test has been removed;
l) 9.3.2: additional requirements for material of connectors and insulating material have been included;
m) The particular requirements for non-metallic material have been clarified;
n) Clause 11: the particular requirements for protection against HAZARDS from fluid and solid foreign objects have been removed;
o) 12.4: an additional subclause relating to microwave radiation has been included;
p) 14.102: the description of switching devices has been clarified;
- Standard372 pagesEnglish languagesale 15% off
- Standard165 pagesEnglish and French languagesale 15% off
IEC 63303:2024 defines general structures and functions of HMI systems. An HMI life cycle example for HMI systems is included. This document specifies requirements and recommendations for activities in each stage of the life cycle including designing, using, and maintaining the HMI system. It also provides requirements and recommendations for functions and performance of HMI systems. The requirements and recommendations in this document are applicable to any controlled process using an HMI to interface to a control system. There can be differences in implementation to meet the specific needs based on the application and controlled process type.
- Standard72 pagesEnglish languagee-Library read for
IEC TS 61508-3-2:2024 covers the general assurance of dependable software used in critical operational-technology (OT) which is running on hardware devices which are specified as part of the OT application. It is particularly aimed at safety-related software which is being developed according to the E/E/PE software functional safety standard IEC 61508-3; in particular, the development of the software follows a Formal Safety Requirements Specification. Successful use of some or all of the assurance points specified in this document enhances the confidence that a particular piece of safety-related software meets the requirements of the SIL of the safety function which it (partially or fully) implements, and thereby increases the systematic capability of the software.
- Technical specification27 pagesEnglish languagesale 15% off
IEC 63303:2024 defines general structures and functions of HMI systems.
An HMI life cycle example for HMI systems is included.
This document specifies requirements and recommendations for activities in each stage of the life cycle including designing, using, and maintaining the HMI system.
It also provides requirements and recommendations for functions and performance of HMI systems.
The requirements and recommendations in this document are applicable to any controlled process using an HMI to interface to a control system. There can be differences in implementation to meet the specific needs based on the application and controlled process type.
- Standard142 pagesEnglish and French languagesale 15% off
IEC 62682:2022 specifies general principles and processes for the management of alarm systems based on controls system and human-machine interfaces (HMI) for facilities in the process industries. It covers all alarms to be presented to the operator through the control system, which includes alarms from basic process control systems, annunciators, packaged systems, and safety instrumented systems. The practices in this document are applicable to continuous, batch, and discrete processes. There can be differences in implementation to meet the specific needs based on process type. The primary function within the alarm system is to notify operators of abnormal process conditions or equipment malfunctions and support the response. The alarm systems can include both the basic process control system (BPCS) and the safety instrumented system (SIS), each of which uses measurements of process conditions and logic to generate alarms. Figure 1 illustrates the concepts of alarm and response dataflow through the alarm system. The alarm system also includes a mechanism for communicating the alarm information to the operator via an HMI, usually a computer screen or an annunciator. Additional functions of the alarm system are an alarm and event log, an alarm historian, and the generation of performance metrics for the alarm system. There are external systems that can use the data from the alarm system.
- Standard84 pagesEnglish languagee-Library read for
IEC 62682:2022 specifies general principles and processes for the management of alarm systems based on controls system and human-machine interfaces (HMI) for facilities in the process industries. It covers all alarms to be presented to the operator through the control system, which includes alarms from basic process control systems, annunciators, packaged systems, and safety instrumented systems.
The practices in this document are applicable to continuous, batch, and discrete processes. There can be differences in implementation to meet the specific needs based on process type.
The primary function within the alarm system is to notify operators of abnormal process conditions or equipment malfunctions and support the response. The alarm systems can include both the basic process control system (BPCS) and the safety instrumented system (SIS), each of which uses measurements of process conditions and logic to generate alarms. Figure 1 illustrates the concepts of alarm and response dataflow through the alarm system. The alarm system also includes a mechanism for communicating the alarm information to the operator via an HMI, usually a computer screen or an annunciator. Additional functions of the alarm system are an alarm and event log, an alarm historian, and the generation of performance metrics for the alarm system. There are external systems that can use the data from the alarm system.
- Standard261 pagesEnglish languagesale 15% off
- Standard168 pagesEnglish and French languagesale 15% off
This part of IEC 61326 covers all equipment within the scope of IEC 61326-1, but is limited to systems and equipment for industrial applications within a specified electromagnetic environment and intended to perform safety functions as defined in IEC 61508 with SIL 1-3. The electromagnetic environments encompassed by this product family standard are industrial, both indoor and outdoor, and based on the requirements of the process industry, specifically chemical/petrochemical/pharmaceutical manufacturing plants using the mitigation measures given in Annex C. The difference between the electromagnetic environment covered by this document compared to the general industrial environment (see IEC 61326-3- 1) is due to the mitigation measures employed against electromagnetic phenomena leading to a specified electromagnetic environment with test values that have been proven in practice. The environment of industrial application with a specified electromagnetic environment typically includes the following characteristics: – industrial area with limited access; – limited use of mobile transmitters; – dedicated cables for power supply and control, signal or communication lines; – separation between power supply and control, signal or communication cables; – factory building mostly consisting of metal construction; – overvoltage/lightning protection by appropriate measures (for example, metal construction of the building or use of protection devices); - pipe heating systems driven by AC main power; - no high-voltage substation close to sensitive areas; - presence of CISPR 11 Group 2 ISM equipment using ISM frequencies only with low power; - competent staff; - periodical maintenance of equipment and systems; - mounting and installation guidelines for equipment and systems. Equipment and systems considered as "proven-in-use" according to IEC 61508 or "prior use" according to IEC 61511 are excluded from the scope of this document. Fire alarm systems and security alarm systems intended for protection of buildings are excluded from the scope of this document.
- Standard41 pagesEnglish languagee-Library read for
IEC 61326-2-3:2020 is available as IEC 61326-2-3:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61326-2-3:2020 specifies more detailed test configurations, operational conditions and performance criteria for transducers with integrated or remote signal conditioning. This document applies only to transducers characterized by their ability to transform, with the aid of an auxiliary energy source, a non-electric quantity to a process-relevant electrical signal, and to output the signal at one or more PORTS. This document includes transducers for electrochemical and biological measured quantities. The transducers covered by this document can be powered by AC or DC voltage and/or by battery or with internal power supply.
- Standard25 pagesEnglish languagee-Library read for
IEC 61326-2-4:2020 is available as IEC 61326-2-4:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61326-2-4:2020 specifies more detailed test configurations, operational conditions and performance criteria than IEC 61326-1 for equipment for - insulation monitoring according to IEC 61557-8; - insulation fault location according to IEC 61557-9. This applies to insulation monitoring devices and for equipment for insulation fault location systems permanently or semi-permanently connected to the distribution system.
- Standard18 pagesEnglish languagee-Library read for
IEC 61326-2-6:2020 is available as IEC 61326-2-6:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61326-2-6:2020 specifies minimum requirements for immunity and emissions regarding electromagnetic compatibility for IN VITRO DIAGNOSTIC (IVD) MEDICAL EQUIPMENT, taking into account the particularities and specific aspects of this electrical equipment and their electromagnetic environment.
- Standard19 pagesEnglish languagee-Library read for
IEC 61326-2-5:2020 is available as IEC 61326-2-5:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61326-2-5:2020 treats the particular features for EMC testing of field devices with field bus interfaces. This part of IEC 61326 covers only the field bus interface of the equipment. This part refers only to field devices intended for use in process control and process measuring. In this document, field devices with interfaces according to IEC 61784-1:2019, CP 3/2 and CP 1/1 as defined in IEC 61784 are covered. Other field bus interfaces may be included in future editions of this document.
- Standard22 pagesEnglish languagee-Library read for
IEC 61326-1:2020 is available as IEC 61326-1:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61326:2020 specifies requirements for immunity and emissions regarding electro¬magnetic compatibility (EMC) for electrical equipment, operating from a supply or battery of less than 1 000 V AC or 1 500 V DC or from the circuit being measured. Equipment intended for professional, industrial-process, industrial-manufacturing and educational use is covered by this part. It includes equipment and computing devices for - measurement and test; - control; - LABORATORY use; - accessories intended for use with the above (such as sample handling equipment), intended to be used in industrial and non-industrial locations.
- Standard28 pagesEnglish languagee-Library read for
IEC 61326-2-1:2020 is available as IEC 61326-2-1:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61326:2020 specifies more detailed test configurations, operational conditions and performance criteria for equipment with test and measurement circuits (internal or, external to the equipment, or both) that are not EMC protected for operational and/or functional reasons, as specified by the manufacturer. The manufacturer specifies the environment for which the product is intended to be used and selects the appropriate test level specifications of IEC 61326-1:2020.
- Standard13 pagesEnglish languagee-Library read for
IEC 61326-2-2:2020 is available as IEC 61326-2-2:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61326-2-2:2020 specifies more detailed test configurations, operational conditions and performance criteria for equipment covered by Annex A of IEC 61326-1:2020 which is: - used for testing, measuring or monitoring of protective measures in low-voltage distribution systems, and; - powered by battery and/or from the circuit measured, and - portable. Examples of such EUTs include, but are not limited to, voltage detectors, insulation testers, earth continuity testers, earth resistance testers, leakage current clamps, loop impedance testers, “residual-current-device-testers” (RCD-testers) and phase sequence testers as defined in IEC 61557 (all parts).
- Standard15 pagesEnglish languagee-Library read for
IEC 61010-2-202:2020 constitutes Part 2-202 of a planned series of standards on industrial-process measurement, control and automation equipment. Safety terms of general use are defined in IEC 61010-1. More specific terms are defined in each part. This part incorporates the safety related requirements of electrically operated valve ACTUATORs and SOLENOIDs. This document does not cover functional safety aspects of electrically operated ACTUATORs and SOLENOIDs.
- Standard41 pagesEnglish languagesale 15% off
- Standard26 pagesEnglish and French languagesale 15% off
IEC 61326-2-5:2020 treats the particular features for EMC testing of field devices with field bus interfaces. This part of IEC 61326 covers only the field bus interface of the equipment. This part refers only to field devices intended for use in process control and process measuring. In this document, field devices with interfaces according to IEC 61784-1:2019, CP 3/2 and CP 1/1 as defined in IEC 61784 are covered. Other field bus interfaces may be included in future editions of this document.
- Standard57 pagesEnglish languagesale 15% off
- Standard38 pagesEnglish and French languagesale 15% off
IEC 61326-2-6:2020 specifies minimum requirements for immunity and emissions regarding electromagnetic compatibility for IN VITRO DIAGNOSTIC (IVD) MEDICAL EQUIPMENT, taking into account the particularities and specific aspects of this electrical equipment and their electromagnetic environment.
- Standard50 pagesEnglish languagesale 15% off
- Standard32 pagesEnglish and French languagesale 15% off
IEC 61326-2-4:2020 specifies more detailed test configurations, operational conditions and performance criteria than IEC 61326-1 for equipment for
- insulation monitoring according to IEC 61557-8;
- insulation fault location according to IEC 61557-9.
This applies to insulation monitoring devices and for equipment for insulation fault location systems permanently or semi-permanently connected to the distribution system.
- Standard46 pagesEnglish languagesale 15% off
- Standard30 pagesEnglish and French languagesale 15% off
IEC 61326:2020 specifies requirements for immunity and emissions regarding electro¬magnetic compatibility (EMC) for electrical equipment, operating from a supply or battery of less than 1 000 V AC or 1 500 V DC or from the circuit being measured. Equipment intended for professional, industrial-process, industrial-manufacturing and educational use is covered by this part. It includes equipment and computing devices for
- measurement and test;
- control;
- LABORATORY use;
- accessories intended for use with the above (such as sample handling equipment),
intended to be used in industrial and non-industrial locations.
- Standard78 pagesEnglish languagesale 15% off
- Standard49 pagesEnglish and French languagesale 15% off
IEC 61326-2-3:2020 specifies more detailed test configurations, operational conditions and performance criteria for transducers with integrated or remote signal conditioning. This document applies only to transducers characterized by their ability to transform, with the aid of an auxiliary energy source, a non-electric quantity to a process-relevant electrical signal, and to output the signal at one or more PORTS. This document includes transducers for electrochemical and biological measured quantities. The transducers covered by this document can be powered by AC or DC voltage and/or by battery or with internal power supply.
- Standard68 pagesEnglish languagesale 15% off
- Standard45 pagesEnglish and French languagesale 15% off
IEC 61326:2020 specifies more detailed test configurations, operational conditions and performance criteria for equipment with test and measurement circuits (internal or, external to the equipment, or both) that are not EMC protected for operational and/or functional reasons, as specified by the manufacturer. The manufacturer specifies the environment for which the product is intended to be used and selects the appropriate test level specifications of IEC 61326-1:2020.
- Standard30 pagesEnglish languagesale 15% off
- Standard20 pagesEnglish and French languagesale 15% off
IEC 61326-2-2:2020 specifies more detailed test configurations, operational conditions and performance criteria for equipment covered by Annex A of IEC 61326-1:2020 which is:
- used for testing, measuring or monitoring of protective measures in low-voltage distribution systems, and;
- powered by battery and/or from the circuit measured, and
- portable.
Examples of such EUTs include, but are not limited to, voltage detectors, insulation testers, earth continuity testers, earth resistance testers, leakage current clamps, loop impedance testers, “residual-current-device-testers” (RCD-testers) and phase sequence testers as defined in IEC 61557 (all parts).
- Standard37 pagesEnglish languagesale 15% off
- Standard24 pagesEnglish and French languagesale 15% off
2017-05-03 - When published - possible update needed to implementation dates of Mother EN & Parts 2 & 3. BT decision to be taken at May 2017 meeting (156th)
- Amendment7 pagesEnglish languagee-Library read for
NEW!IEC 61326-3-1:2017 is available as IEC 61326-3-1:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61326-3-1:2017 covers all equipment within the scope of IEC 61326-1, but is limited to systems and equipment for industrial applications intended to perform safety functions as defined in IEC 61508 with SIL 1-3. This second edition cancels and replaces the first edition published in 2008. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - extension of the frequency range up to 6 GHz for the radio-frequency electromagnetic field test according to IEC 61000-4-3, - replacement of the performance criterion FS with DS according to the generic standard IEC 61000-6-7, - adding Table 1 - Aspects to be considered during application of performance criterion DS, - including immunity tests for devices with current consumption > 16 A according to IEC 61000-4-34, - updating Table 8 - Frequency ranges of mobile transmitters and ISM equipment, - updating Figure A.1 and Figure 1 for better readability.
- Standard45 pagesEnglish languagee-Library read for
IEC TR 61511-4:2020(E), Functional safety - safety instrumented systems for the process industry sector, which is a Technical Report:
• specifies the rationale behind all clauses and the relationship between them,
• raises awareness for the most common misconceptions and misinterpretations of the clauses and the changes related to them,
• explains the differences between Ed. 1 and Ed. 2 of IEC 61511-1 and the reasons behind the changes,
• presents high level summaries of how to fulfil the requirements of the clauses, and
• explains differences in terminology between IEC 61508-4:2010 and IEC 61511-1 Ed. 2.
- Technical report39 pagesEnglish languagesale 15% off
Covers the method to be used to systematically assess the performance of industrial-process measurement and control systems.
- Standard35 pagesEnglish languagee-Library read for
Describes in detail the method to be used to systematically assess the functionality of an industrial-process measurement and control system.
- Standard38 pagesEnglish languagee-Library read for
Details the assessment methodology of industrial-process measurement and control systems. Describes the method for analyzing the objectives given for the assessment, the method for weighing the relative importance of the various system properties and influencing conditions, and for determining an assessment programme.
- Standard41 pagesEnglish languagee-Library read for
Provides methods and procedures for the assessment of industrial-process measurement and control systems. Is intended for users and manufacturers, and also those carrying out assessments as an independent party.
- Standard48 pagesEnglish languagee-Library read for
The treatment of safety in this standard is confined to hazards that can be present within the industrial-process measurement and control system itself. Considerations of hazards that can be introduced by the process or equipment under control of the industrial-process measurement and control system to be assessed are excluded. If the system mission includes activities which could affect the safety of the process or equipment under control, the requirements of these activities are the subject of IEC 61508.
- Standard21 pagesEnglish languagee-Library read for
IEC 61069-6:2016 specifies the detailed method of the assessment of operability of basic control system (BCS), based on the basic concepts of IEC 61069-1 and methodology of IEC 61069-2; defines basic categorization of operability properties; describes the factors that influence operability and which need to be taken into account when evaluating operability; provides guidance in selecting techniques from a set of options (with references) for evaluating the operability. This second edition cancels and replaces the first edition published in 1998. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - reorganization of the material of IEC 61069-6:1998 to make the overall set of standards more organized and consistent; - IEC TS 62603-1 has been incorporated into this edition.
- Standard30 pagesEnglish languagee-Library read for
Describes in detail the method to systematically assess the dependability of industrial-process measurement and control systems. Uses the assessment methodology given in EN 61069-2.
- Standard38 pagesEnglish languagee-Library read for
Assessment methodology detailed in EN 61069-2 is applied to obtain the assessment programme of the non-task-related properties. Each of the properties is analyes, and the criteria to be taken into account when assessing non-task-related properties are described. References are made to supplementary evaluation techniques.
- Standard39 pagesEnglish languagee-Library read for
IEC 61511-0:2018(E) provides an overview of the other three parts of IEC 61511 Functional safety - safety instrumented systems for the process industry sector. There are many hazards in process industries that can lead to loss of containment, resulting in an impact on health, safety, environment and plant assets. Process safety is best achieved by using inherently safe processes. However, when this is not practical or possible, protective systems are required to mitigate the risk of hazards to an acceptable level. There are three parts to this series:
IEC 61511-1:2016, Functional safety - Safety instrumented systems for the process industry sector - Part 1: Framework, definitions, system, hardware and application programming requirements
IEC 61511-2:2016, Functional safety - Safety instrumented systems for the process industry sector - Part 2: Guidelines for the application of IEC 61511-1:2016
IEC 61511-3:2016, Functional safety - Safety instrumented systems for the process industry sector - Part 3: Guidance for the determination of the required safety integrity levels
- Technical report8 pagesEnglish languagesale 15% off
- Standard5 pagesEnglish languagesale 15% off
- Standard9 pagesEnglish and French languagesale 15% off
IEC 61511-1:2016 gives requirements for the specification, design, installation, operation and maintenance of a safety instrumented system (SIS), so that it can be confidently entrusted to achieve or maintain a safe state of the process. IEC 61511-1 has been developed as a process sector implementation of IEC 61508:2010. The contents of the corrigendum of September 2016 have been included in this copy.
- Standard163 pagesEnglish languagesale 15% off
- Standard286 pagesEnglish languagesale 15% off
- Standard350 pagesEnglish and French languagesale 15% off
- Standard175 pagesEnglish and French languagesale 15% off
IEC 61326-3-1:2017 covers all equipment within the scope of IEC 61326-1, but is limited to systems and equipment for industrial applications intended to perform safety functions as defined in IEC 61508 with SIL 1-3.
This second edition cancels and replaces the first edition published in 2008. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- extension of the frequency range up to 6 GHz for the radio-frequency electromagnetic field test according to IEC 61000-4-3,
- replacement of the performance criterion FS with DS according to the generic standard IEC 61000-6-7,
- adding Table 1 - Aspects to be considered during application of performance criterion DS,
- including immunity tests for devices with current consumption > 16 A according to IEC 61000-4-34,
- updating Table 8 - Frequency ranges of mobile transmitters and ISM equipment,
- updating Figure A.1 and Figure 1 for better readability.
- Standard130 pagesEnglish languagesale 15% off
- Standard83 pagesEnglish and French languagesale 15% off
IEC 61326-3-2:2017 covers all equipment within the scope of IEC 61326-1, but is limited to systems and equipment for industrial applications within a specified electromagnetic environment and intended to perform safety functions as defined in IEC 61508 with SIL 1-3.
This second edition cancels and replaces the first edition published in 2008. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- extension of the frequency range up to 6 GHz for the radio-frequency electromagnetic field test according to IEC 61000-4-3,
- replacement of the performance criterion FS with DS according to the generic standard IEC 61000-6-7,
- adding Table 1 - Aspects to be considered during application of performance criterion DS,
- including immunity tests for devices with current consumption > 16 A according to IEC 61000-4-34,
- updating Figure A.1 and Figure 1 for better readability,
- adding tests according to IEC 61000-4-16 to replace the tests according to IEC 61000-4-6 in the frequency range between 10 kHz and 150 kHz.
- Standard117 pagesEnglish languagesale 15% off
- Standard74 pagesEnglish and French languagesale 15% off
IEC 61511-1:2016 is available as IEC 61511-1:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61511-1:2016 gives requirements for the specification, design, installation, operation and maintenance of a safety instrumented system (SIS), so that it can be confidently entrusted to achieve or maintain a safe state of the process. IEC 61511-1 has been developed as a process sector implementation of IEC 61508:2010.
- Standard87 pagesEnglish languagee-Library read for
IEC 61511-3:2016 is available as IEC 61511-3:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61511-3:2016 applies when functional safety is achieved using one or more SIF for the protection of either personnel, the general public, or the environment; may be applied in non-safety applications such as asset protection; illustrates typical hazard and risk assessment methods that may be carried out to define the safety functional requirements and SIL of each SIF; illustrates techniques/measures available for determining the required SIL; provides a framework for establishing SIL but does not specify the SIL required for specific applications; does not give examples of determining the requirements for other methods of risk reduction. This second edition cancels and replaces the first edition published in 2003. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: Additional H&RA example(s) and quantitative analysis consideration annexes are provided.
- Standard103 pagesEnglish languagee-Library read for
IEC 61511-2:2016 is available as IEC 61511-2:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61511-2:2016 provides guidance on the specification, design, installation, operation and maintenance of SIFs and related SIS as defined in IEC 61511-1:2016. This second edition cancels and replaces the first edition published in 2003. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: guidance examples based on all phases of the safety life cycle provided based on usage experience with IEC61511 1st edition; annexes replaced to address transition from software to application programming.
- Standard207 pagesEnglish languagee-Library read for
IEC 61010-2-201:2017 specifies safety requirements and related verification tests for any product performing the function of control equipment and/or their associated peripherals. In addition, these products have as their intended use the command and control of machines, automated manufacturing and industrial processes, e.g. discrete and continuous control.
This second edition cancels and replaces the first edition published in 2013. This edition constitutes a technical revision. This second edition includes the following significant technical changes with respect to the previous edition;
a) clarify, change, delete definitions which were causing confusion,
b) change and clarify the temperature testing methodology,
c) change documentation methodologies allowed,
d) change some terminal markings,
e) add clarity to some of the informative annexes,
f) add Annex E with changes,
g) add Annexes AA – FF.
- Standard235 pagesEnglish languagesale 15% off
- Standard156 pagesEnglish and French languagesale 15% off
IEC 61511-2:2016 provides guidance on the specification, design, installation, operation and maintenance of SIFs and related SIS as defined in IEC 61511-1:2016. This second edition cancels and replaces the first edition published in 2003. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- guidance examples based on all phases of the safety life cycle provided based on usage experience with IEC 61511 1st edition;
- annexes replaced to address transition from software to application programming.
- Standard682 pagesEnglish languagesale 15% off
- Standard445 pagesEnglish and French languagesale 15% off
IEC 61511-3:2016 applies when functional safety is achieved using one or more SIF for the protection of either personnel, the general public, or the environment; may be applied in non-safety applications such as asset protection; illustrates typical hazard and risk assessment methods that may be carried out to define the safety functional requirements and SIL of each SIF; illustrates techniques/measures available for determining the required SIL; provides a framework for establishing SIL but does not specify the SIL required for specific applications; does not give examples of determining the requirements for other methods of risk reduction. This second edition cancels and replaces the first edition published in 2003. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: Additional H&RA example(s) and quantitative analysis consideration annexes are provided.
- Standard332 pagesEnglish languagesale 15% off
- Standard224 pagesEnglish and French languagesale 15% off
Frequently Asked Questions
SC 65A is a Technical Committee within the International Electrotechnical Commission (IEC). It is named "Safety aspects" and is responsible for: To prepare international standards regarding the safety and related aspects impacting safety of systems used in industrial process measurement, control and automation. This committee has published 190 standards.
SC 65A develops IEC standards. The scope of work includes: To prepare international standards regarding the safety and related aspects impacting safety of systems used in industrial process measurement, control and automation. Currently, there are 190 published standards from this technical committee.
The International Electrotechnical Commission (IEC) is the world's leading organization for the preparation and publication of international standards for electrical, electronic, and related technologies. Founded in 1906, the IEC provides a global platform for companies, industries, and governments to meet, discuss, and develop the international standards they require.
A Technical Committee (TC) in IEC is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.