This part of CISPR 16 specifies the characteristics and performance of equipment for the measurement of radiated disturbances in the frequency range 9 kHz to 18 GHz. Specifications for antennas and test sites are included.
NOTE In accordance with IEC Guide 107 [1], 1 CISPR 16-1-4 is a basic EMC publication for use by product committees of the IEC. As stated in Guide 107, product committees are responsible for determining the applicability of the EMC standard. CISPR and its sub-committees are prepared to cooperate with product committees in the evaluation of the value of particular EMC tests for specific products.
The requirements of this publication apply at all frequencies and for all levels of radiated disturbances within the CISPR indicating range of the measuring equipment.
Methods of measurement are covered in CISPR 16-2-3, further information on radio disturbance is given in CISPR TR 16-3 [2], and uncertainties, statistics, and limit modelling are covered in CISPR 16-4 series.

  • Standard
    172 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61326-2-7:2025 specifies the EMC test requirements for process automation equipment using at least one Ethernet APL (Ethernet ADVANCED PHYSICAL LAYER) compliant port according IEC TS 63444. The type of equipment covered by this document includes INFRASTRUCTURE DEVICES such as switches as well as measurement and control devices. This document provides requirements for the EMC test setups of the APL interface for devices intended for use in process control and process measurement.
The other functions of the equipment remain covered by other parts of the IEC 61326 series.
NOTE Ethernet-APL uses IEEE Std. 802.3 2022 Ethernet Physical Layer 10BASE-T1L, suitable to be used for full-duplex communication over a single balanced pair of conductors.
The test levels are based on the intended environment as stated in the product’s specification or user documentation and selected appropriately from IEC 61326-1.

  • Standard
    39 pages
    English language
    sale 15% off

This part of CISPR 16 specifies the characteristics and performance of equipment for the measurement of radiated disturbances in the frequency range 9 kHz to 18 GHz. Specifications for antennas and test sites are included.
NOTE In accordance with IEC Guide 107 [1], 1 CISPR 16-1-4 is a basic EMC publication for use by product committees of the IEC. As stated in Guide 107, product committees are responsible for determining the applicability of the EMC standard. CISPR and its sub-committees are prepared to cooperate with product committees in the evaluation of the value of particular EMC tests for specific products.
The requirements of this publication apply at all frequencies and for all levels of radiated disturbances within the CISPR indicating range of the measuring equipment.
Methods of measurement are covered in CISPR 16-2-3, further information on radio disturbance is given in CISPR TR 16-3 [2], and uncertainties, statistics, and limit modelling are covered in CISPR 16-4 series.

  • Standard
    172 pages
    English language
    sale 10% off
    e-Library read for
    1 day

CISPR TR 16-4-4:2025 which is a Technical Report, establishes the CISPR model for the calculation of limits for the protection of radio services, based on data from the IEC Radio Services Database (RSD) and estimations of the input values for related probabilistic factors. This is part of the process of the derivation of disturbance limits in the radio frequency spectrum for use in publications containing emission requirements Application of this document leads to a frequency dependent limit result for a particular disturbance phenomenon and the considered product or product type establishing the technical basis in the CISPR limit specification procedure.
NOTE Non-technical parameters and terms that can be considered to influence a limit for inclusion in IEC publications are excluded from the modelling (see also Clause 4.6.5.3).
This third edition cancels and replaces the second edition published in 2007, Amendment 1:2017 and Amendment 2:2020. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) full revision of the limit calculation model;
b) the content on statistics of complaints was taken from this publication and published as separate document (CISPR TR 16-4-6);
c) application cases/rationales were separated from the model and will be handled in another document to be drafted.

  • Technical report
    57 pages
    English language
    sale 15% off

CISPR 16-1-4:2025 specifies the characteristics and performance of equipment for the measurement of radiated disturbances in the frequency range 9 kHz to 18 GHz. Specifications for antennas and test sites are included.
NOTE In accordance with IEC Guide 107. CISPR 16-1-4 is a basic EMC publication for use by product committees of the IEC. As stated in Guide 107, product committees are responsible for determining the applicability of the EMC standard. CISPR and its sub-committees are prepared to cooperate with product committees in the evaluation of the value of particular EMC tests for specific products.
The requirements of this publication apply at all frequencies and for all levels of radiated disturbances within the CISPR indicating range of the measuring equipment. Methods of measurement are covered in CISPR 16-2-3, further information on radio disturbance is given in CISPR TR 16-3, and uncertainties, statistics, and limit modelling are covered in CISPR 16-4 series. This fifth edition cancels and replaces the fourth edition published in 2019, Amendment 1:2020 and Amendment 2:2023. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) revision of the definition 3.1.7 and of the general introduction 8.1.1 for CMAD;
b) introduction of a new cable termination device, the very high frequency line impedance stabilization network (VHF-LISN) in 8.2;
c) addition of definition 3.1.34 for VHF-LISN, 3.1.20 for reference ground, 3.1.21 for reference ground plane and 3.1.31 for TN‑C‑S power system;
d) various non-technical editorial, style, and wording adjustments for consistency with drafting rules.

  • Standard
    515 pages
    English language
    sale 15% off

Considers immunity tests for electric and/or electronic equipment (apparatus and system) in its electromagnetic environment. Only conducted phenomena are considered, including immunity tests for equipment connected to public and industrial networks. Establishes a reference for evaluating the immunity of electrical and electronic equipment when subjected to unbalanced power supply voltage. Applies to 50 Hz/60 Hz three-phase powered electrical and/or electronic equipment with rated line current up to 16 A per phase.

  • Standard
    50 pages
    English language
    sale 15% off
  • Standard
    41 pages
    English and French language
    sale 15% off
  • Standard
    41 pages
    English and French language
    sale 15% off
  • Standard
    10 pages
    English language
    sale 15% off
  • Standard
    11 pages
    French language
    sale 15% off
  • Standard
    21 pages
    English and French language
    sale 15% off

IEC 61326-2-6:2025 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of IN VITRO DIAGNOSTIC MEDICAL ELECTRICAL EQUIPMENT (IVD MEE). This part of IEC 61326 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of IVD MEE in the presence of electromagnetic disturbances and to electromagnetic disturbances emitted by IVD MEE.
BASIC SAFETY with regard to electromagnetic disturbances is applicable to all IVD MEE.
NOTE 1 Performance with respect to electromagnetic disturbances other than ESSENTIAL PERFORMANCE is the subject of IEC 61326-1:2020
NOTE 2 IT equipment can be a part of an IVD MEE, if it is required to maintain BASIC SAFETY or ESSENTIAL PERFORMANCE.
This edition includes the following significant technical changes with respect to the previous edition:
- Update of the document with respect to test levels and documentation.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61326-2-6:2025 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of IN VITRO DIAGNOSTIC MEDICAL ELECTRICAL EQUIPMENT (IVD MEE). This part of IEC 61326 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of IVD MEE in the presence of electromagnetic disturbances and to electromagnetic disturbances emitted by IVD MEE. BASIC SAFETY with regard to electromagnetic disturbances is applicable to all IVD MEE. NOTE 1 Performance with respect to electromagnetic disturbances other than ESSENTIAL PERFORMANCE is the subject of IEC 61326-1:2020 NOTE 2 IT equipment can be a part of an IVD MEE, if it is required to maintain BASIC SAFETY or ESSENTIAL PERFORMANCE. This edition includes the following significant technical changes with respect to the previous edition: - Update of the document with respect to test levels and documentation.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61000 defines the immunity test methods and range of preferred test levels for electrical and electronic equipment connected to low-voltage power supply networks for voltage dips, short interruptions, and voltage variations. This standard applies to electrical and electronic equipment having a rated input current exceeding 16 A per phase. It covers equipment installed in residential areas as well as industrial machinery, specifically voltage dips and short interruptions for equipment connected to either 50 Hz or 60 Hz a.c. networks, including 1-phase and 3-phase mains. The object of this standard is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to voltage dips, short interruptions and voltage variations. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of equipment or a system against a defined phenomenon. It has the status of a Basic EMC Publication in accordance with IEC Guide 107.

  • Standard
    69 pages
    English language
    sale 15% off
  • Standard
    63 pages
    English and French language
    sale 15% off
  • Standard
    66 pages
    English and French language
    sale 15% off

IEC 61326-2-6:2025 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of IN VITRO DIAGNOSTIC MEDICAL ELECTRICAL EQUIPMENT (IVD MEE). This part of IEC 61326 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of IVD MEE in the presence of electromagnetic disturbances and to electromagnetic disturbances emitted by IVD MEE.
BASIC SAFETY with regard to electromagnetic disturbances is applicable to all IVD MEE.
NOTE 1 Performance with respect to electromagnetic disturbances other than ESSENTIAL PERFORMANCE is the subject of IEC 61326-1:2020
NOTE 2 IT equipment can be a part of an IVD MEE, if it is required to maintain BASIC SAFETY or ESSENTIAL PERFORMANCE.
This edition includes the following significant technical changes with respect to the previous edition:
- Update of the document with respect to test levels and documentation.

  • Standard
    70 pages
    English and French language
    sale 15% off

This document specifies general conditions, defines terms, gives practical guidelines and establishes the basic principles of the vehicle tests used in the ISO 11451 series, for determining the immunity of passenger cars and commercial vehicles to electrical disturbances from narrowband radiated electromagnetic energy, regardless of the vehicle propulsion system (e.g. spark-ignition engine, diesel engine, electric motor). The electromagnetic disturbances considered are limited to continuous narrowband electromagnetic fields. A wide frequency range (0,01 MHz to 18 000 MHz) is allowed for the immunity testing in the ISO 11451 series.

  • Standard
    39 pages
    English language
    sale 15% off

This document describes the introduction of radiated immunity testing for the components and vehicles equipped with V2X communications. The link communication connection and V2X scenario simulation are considered to make the V2X functions and their communications operate normally during the immunity testing. Examples of monitoring are also discussed to show the electromagnetic interference reactions of the device with V2X under test. In addition, test hints are described to provide information on radiated immunity for V2X. Technical specifications are not within the scope of this document.

  • Technical report
    47 pages
    English language
    sale 15% off

This document specifies general conditions, defines terms, gives practical guidelines, and establishes the basic principles of the component tests used in the other parts of the ISO 11452 series for determining the immunity of electronic components of passenger cars and commercial vehicles to electrical disturbances from narrowband radiated electromagnetic energy, regardless of the vehicle propulsion system (e.g. spark-ignition engine, diesel engine, electric motor). The electromagnetic disturbances considered are limited to continuous narrowband electromagnetic fields. A wide frequency range (d.c. and 15 Hz to 18 GHz) is allowed for the immunity testing of the components in the ISO 11452 series.

  • Standard
    47 pages
    English language
    sale 15% off

This document specifies a method for testing the immunity of passenger cars and commercial vehicles to electrical disturbances from off-vehicle radiation sources, regardless of the vehicle propulsion system (e.g. spark ignition engine, diesel engine, electric motor). The electromagnetic disturbances considered are limited to continuous narrowband electromagnetic fields. While this document refers specifically to passenger cars and commercial vehicles, generalized as “vehicle(s)”, it can readily be applied to other types of vehicles. ISO 11451-1 specifies general test conditions, definitions, practical use, and basic principles of the test procedure. Function performance status classification guidelines for immunity to electromagnetic radiation from an off-vehicle radiation source are given in Annex A.

  • Standard
    42 pages
    English language
    sale 15% off
  • Standard
    42 pages
    English language
    sale 15% off

IEC 61000-4-2: 2025 relates to the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges from operators directly and from personnel to adjacent objects. It additionally specifies ranges of test levels which relate to different environmental, and installation conditions and establishes test procedures. The objective of this document is to establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to electrostatic discharges. In addition, it includes electrostatic discharges which can occur from personnel to objects near the equipment. This document specifies:
- ideal waveform of the discharge current;
- range of test levels;
- test equipment;
- test setup;
- test procedure;
- calibration procedure;
- measurement uncertainty.
This document gives specifications for tests performed in laboratories and guidance to post-installation tests. This document is not intended to specify the tests to be applied to particular apparatus or systems. The main aim is to give a general basic reference to all concerned product committees. The product committees remain responsible for the appropriate choice of the tests and the severity level to be applied to their equipment. This document excludes tests intended to evaluate the ESD sensitivity of devices during handling and packaging. It is not intended for use in characterizing the performance of ESD protection circuit IEC Guide 107.
This document forms Part 4-2 of IEC 61000. It has the status of a basic EMC publication in accordance with IEC Guide 107. This third edition cancels and replaces the second edition published in 2008. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) added a calibration requirement for ESD generators with air discharge tip;
b) added a normative annex for test setups for particular kind of equipment (see Annex I);
c) added an informative annex for wearable devices (see Annex J);
d) added an informative annex on how to select test points and give guidance on how to specify the number of pulses for direct contact discharges (see Annex E);
e) moved Clause 9 into a new informative annex (see Annex K);
f) improvement of the current calibration procedure;
g) improvement of the measurement uncertainty considerations with examples of uncertainty budgets;
h) because post-installation tests cannot be performed in a controlled environment, this test method has been moved into a new informative Annex G.

  • Standard
    82 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-4-2: 2025 relates to the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges from operators directly and from personnel to adjacent objects. It additionally specifies ranges of test levels which relate to different environmental, and installation conditions and establishes test procedures. The objective of this document is to establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to electrostatic discharges. In addition, it includes electrostatic discharges which can occur from personnel to objects near the equipment. This document specifies: - ideal waveform of the discharge current; - range of test levels; - test equipment; - test setup; - test procedure; - calibration procedure; - measurement uncertainty. This document gives specifications for tests performed in laboratories and guidance to post-installation tests. This document is not intended to specify the tests to be applied to particular apparatus or systems. The main aim is to give a general basic reference to all concerned product committees. The product committees remain responsible for the appropriate choice of the tests and the severity level to be applied to their equipment. This document excludes tests intended to evaluate the ESD sensitivity of devices during handling and packaging. It is not intended for use in characterizing the performance of ESD protection circuit IEC Guide 107. This document forms Part 4-2 of IEC 61000. It has the status of a basic EMC publication in accordance with IEC Guide 107. This third edition cancels and replaces the second edition published in 2008. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) added a calibration requirement for ESD generators with air discharge tip; b) added a normative annex for test setups for particular kind of equipment (see Annex I); c) added an informative annex for wearable devices (see Annex J); d) added an informative annex on how to select test points and give guidance on how to specify the number of pulses for direct contact discharges (see Annex E); e) moved Clause 9 into a new informative annex (see Annex K); f) improvement of the current calibration procedure; g) improvement of the measurement uncertainty considerations with examples of uncertainty budgets; h) because post-installation tests cannot be performed in a controlled environment, this test method has been moved into a new informative Annex G.

  • Standard
    82 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-4-2: 2025 relates to the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges from operators directly and from personnel to adjacent objects. It additionally specifies ranges of test levels which relate to different environmental, and installation conditions and establishes test procedures. The objective of this document is to establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to electrostatic discharges. In addition, it includes electrostatic discharges which can occur from personnel to objects near the equipment. This document specifies:
- ideal waveform of the discharge current;
- range of test levels;
- test equipment;
- test setup;
- test procedure;
- calibration procedure;
- measurement uncertainty.
This document gives specifications for tests performed in laboratories and guidance to post-installation tests. This document is not intended to specify the tests to be applied to particular apparatus or systems. The main aim is to give a general basic reference to all concerned product committees. The product committees remain responsible for the appropriate choice of the tests and the severity level to be applied to their equipment. This document excludes tests intended to evaluate the ESD sensitivity of devices during handling and packaging. It is not intended for use in characterizing the performance of ESD protection circuit IEC Guide 107.
This document forms Part 4-2 of IEC 61000. It has the status of a basic EMC publication in accordance with IEC Guide 107. This third edition cancels and replaces the second edition published in 2008. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) added a calibration requirement for ESD generators with air discharge tip;
b) added a normative annex for test setups for particular kind of equipment (see Annex I);
c) added an informative annex for wearable devices (see Annex J);
d) added an informative annex on how to select test points and give guidance on how to specify the number of pulses for direct contact discharges (see Annex E);
e) moved Clause 9 into a new informative annex (see Annex K);
f) improvement of the current calibration procedure;
g) improvement of the measurement uncertainty considerations with examples of uncertainty budgets;
h) because post-installation tests cannot be performed in a controlled environment, this test method has been moved into a new informative Annex G.

  • Standard
    163 pages
    English and French language
    sale 15% off

IEC 61000-4-41:2024 relates to broadband radiated disturbances generated by, for example, communication devices or services, transmitters or industrial electromagnetic sources or any other devices capable of generating such a signal.
The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to broadband radiated electromagnetic fields.
This document specifies testing in the frequency ranges above 80 MHz, limited only by the capabilities of commercially available test instrumentation.
It forms Part 4-41 of IEC 61000. It has the status of a basic EMC publication in accordance with IEC Guide 107.

  • Standard
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-4-41:2024 relates to broadband radiated disturbances generated by, for example, communication devices or services, transmitters or industrial electromagnetic sources or any other devices capable of generating such a signal. The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to broadband radiated electromagnetic fields. This document specifies testing in the frequency ranges above 80 MHz, limited only by the capabilities of commercially available test instrumentation. It forms Part 4-41 of IEC 61000. It has the status of a basic EMC publication in accordance with IEC Guide 107.

  • Standard
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60364-4-44:2024 provides requirements for the safety of electrical installations in the event of voltage disturbances and electromagnetic disturbances generated for different specified reasons. The requirements of this document are not intended to apply to systems for distribution of energy to the public, or power generation and transmission for such systems (see the scope of IEC 60364-1) although such disturbances can be conducted into or between electrical installations via these supply systems. This third edition cancels and replaces the second edition published in 2007, Amendment 1:2015 and Amendment 2:2018. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) the structure of the document has been updated in accordance with the ISO/IEC Directives, Part 2:2021: the terms, definitions and symbols have been regrouped under a new Subclause 440.3, the tables and figures have been renumbered;
b) Clause 443 has been amended to better introduce the DC SPD and to improve some of the wording.

  • Standard
    116 pages
    English language
    sale 15% off

IEC 61000-4-41:2024 relates to broadband radiated disturbances generated by, for example, communication devices or services, transmitters or industrial electromagnetic sources or any other devices capable of generating such a signal.
The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to broadband radiated electromagnetic fields.
This document specifies testing in the frequency ranges above 80 MHz, limited only by the capabilities of commercially available test instrumentation.
It forms Part 4-41 of IEC 61000. It has the status of a basic EMC publication in accordance with IEC Guide 107.

  • Standard
    103 pages
    English and French language
    sale 15% off

IEC 62841-4-1:2017 applies to chain saws for cutting wood and designed for use by one person. This standard does not cover chain saws designed for use in conjunction with a guide-plate and riving knife or in any other way such as with a support or as a stationary or transportable machine.
This standard does not apply to chain saws for tree service as defined in ISO 11681-2; or pole-mounted pruners.
Pole-mounted pruners will be covered by a future part of IEC 62841.
The chain saws covered by this standard are designed only to be operated with the right hand on the rear handle and the left hand on the front handle.
This Part 4-1 is to be used in conjunction with the first edition of IEC 62841-1:2014.
The attention of National Committees is drawn to the fact that equipment manufacturers and testing organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests.
It is the recommendation of the committee that the content of this publication be adopted for implementation nationally not earlier than 36 months from the date of publication.

  • Standard
    160 pages
    English language
    sale 15% off
  • Standard
    111 pages
    English and French language
    sale 15% off

IEC 61000-2-4:2024 is available as IEC 61000-2-4:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 61000-2-4:2024 is related to conducted disturbances in the frequency range from 0 kHz to 150 kHz. It gives compatibility levels in differential mode (L-L and L-N) for industrial locations, with a nominal voltage up to 35 kV and a nominal frequency of 50 Hz or 60 Hz.
NOTE 1 Industrial locations are defined in 3.1.8.
Power distribution systems on ships, aircraft, offshore platforms and railways are not included.
NOTE 2 See also Annex E. The compatibility levels specified in this document apply at the in-plant point of coupling (IPC). The level of the low-frequency disturbances at the terminals of equipment receiving its supply from the IPC is generally assumed to be similar to the disturbance level at the IPC itself. However, in some situations this is not the case, particularly when a long feeder is dedicated to the supply of a particular load, or when a disturbance is generated or amplified within the installation of which the equipment forms a part.
Compatibility levels are specified for the types of low-frequency electromagnetic disturbances expected at any in-plant point of coupling (IPC) within industrial locations, for guidance in the definition of:
a) limits for disturbance emissions in industrial power distribution systems (including the planning levels defined in 3.1.5);
NOTE 3 A very wide range of conditions is possible in the electromagnetic environments of industrial networks. These are approximated in this document by the three classes described in Clause 4. However, it is the responsibility of the operator of such a network to take account of the particular electromagnetic and economic conditions, including equipment characteristics, in setting the above-mentioned limits.
b) immunity levels for the equipment within these systems.
The disturbance phenomena considered are:
- voltage deviations;
- voltage dips and short interruptions;
- voltage imbalance;
- power-frequency variations;
- harmonics up to order 40;
- interharmonics up to the 40th harmonic;
- voltage components above the 40th harmonic up to 150 kHz;
- DC component;
- transient overvoltages.
The compatibility levels are given for different classes of environment determined by the characteristics of the supply network and loads.
NOTE 4 Compatibility levels at the point of common coupling (PCC) on public networks are specified in IEC 61000‑2‑2 for low-voltage networks and IEC 61000‑2‑12 for medium-voltage networks. IEC TR 61000‑3‑6 and IEC TR 61000‑3‑7 describe the approach of power distribution system operators to the limitation of emissions from installations and large loads.
This third edition cancels and replaces the second edition published in 2002. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) introduction of new classes 2a, 2b and 2L (former class 2);
b) modification of existing compatibility levels for class 3;
c) addition of compatibility levels in the frequency range 2 kHz to 150 kHz;
d) addition of compatibility levels using a new quantity: partial weighted harmonic distortion (PWHD).

  • Standard
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day

CISPR TR 16-4-6:2024 which is a Technical Report, applies to the acquisition, processing and preparation of statistical data of radio interference cases to facilitate the evaluation of the effectiveness of CISPR standards with respect to their potential to prevent radio frequency interference (RFI). This document also provides a method for the analysis and evaluation of the residual risk of occurrence of the incidence of RFI in the electromagnetic environment. This document also provides guidance for how an interested party can verify the root cause of RFI. This can be applied to either a reported RFI case or a case otherwise suspected of constituting an “RFI scenario”, by inspection and field strength measurements at the local site in the given electromagnetic environment. Acquisition of statistical data according to this document only encompasses RFI incidences which affect radio reception by radio receivers or respective receiver components.

  • Technical report
    33 pages
    English language
    sale 15% off

IEC 61000-2-4:2024 is available as IEC 61000-2-4:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61000-2-4:2024 is related to conducted disturbances in the frequency range from 0 kHz to 150 kHz. It gives compatibility levels in differential mode (L-L and L-N) for industrial locations, with a nominal voltage up to 35 kV and a nominal frequency of 50 Hz or 60 Hz. NOTE 1 Industrial locations are defined in 3.1.8. Power distribution systems on ships, aircraft, offshore platforms and railways are not included. NOTE 2 See also Annex E. The compatibility levels specified in this document apply at the in-plant point of coupling (IPC). The level of the low-frequency disturbances at the terminals of equipment receiving its supply from the IPC is generally assumed to be similar to the disturbance level at the IPC itself. However, in some situations this is not the case, particularly when a long feeder is dedicated to the supply of a particular load, or when a disturbance is generated or amplified within the installation of which the equipment forms a part. Compatibility levels are specified for the types of low-frequency electromagnetic disturbances expected at any in-plant point of coupling (IPC) within industrial locations, for guidance in the definition of: a) limits for disturbance emissions in industrial power distribution systems (including the planning levels defined in 3.1.5); NOTE 3 A very wide range of conditions is possible in the electromagnetic environments of industrial networks. These are approximated in this document by the three classes described in Clause 4. However, it is the responsibility of the operator of such a network to take account of the particular electromagnetic and economic conditions, including equipment characteristics, in setting the above-mentioned limits. b) immunity levels for the equipment within these systems. The disturbance phenomena considered are: - voltage deviations; - voltage dips and short interruptions; - voltage imbalance; - power-frequency variations; - harmonics up to order 40; - interharmonics up to the 40th harmonic; - voltage components above the 40th harmonic up to 150 kHz; - DC component; - transient overvoltages. The compatibility levels are given for different classes of environment determined by the characteristics of the supply network and loads. NOTE 4 Compatibility levels at the point of common coupling (PCC) on public networks are specified in IEC 61000‑2‑2 for low-voltage networks and IEC 61000‑2‑12 for medium-voltage networks. IEC TR 61000‑3‑6 and IEC TR 61000‑3‑7 describe the approach of power distribution system operators to the limitation of emissions from installations and large loads. This third edition cancels and replaces the second edition published in 2002. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) introduction of new classes 2a, 2b and 2L (former class 2); b) modification of existing compatibility levels for class 3; c) addition of compatibility levels in the frequency range 2 kHz to 150 kHz; d) addition of compatibility levels using a new quantity: partial weighted harmonic distortion (PWHD).

  • Standard
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document applies to electrical equipment using signals in the frequency range 3 kHz to 95 kHz to transmit or receive information on low voltage electrical systems, for electricity suppliers and distributors.
Mains communicating equipment (MCE) may fall into one of the two following categories:
-   MCE implementing transmission or reception of information on LV distribution networks or installations of network users connected to the public electricity distribution network as the sole function. Immunity requirements for such equipment are entirely covered by this document;
-   MCE being equipment covered by the scope of other standards, integrating mains communication as one of their functions. In this case, only the immunity requirements for the mains communication function of such equipment are covered by the scope of this document. Immunity requirements for all other available functions of this equipment are covered by the relevant product standard or generic standard.
The object of this document is to contribute to ensuring EMC in general. It specifies essential immunity requirements and test methods, including those tests which are to be performed during type-testing of MCE, for electromagnetic interference (EMI) generated on LV installations.
It defines the methods and requirements for testing immunity of MCE on meeting the essential requirements of the EMCD. Test requirements are specified for each port considered.
Furthermore, it provides guidelines for the assessment of the performance of the communication function of an MCE. Normative specifications are under consideration.
This document gives immunity requirements which are applicable to MCE used by electricity suppliers and distributors (e.g. DSOs) for purposes like energy management and network monitoring and automation. The levels do not however cover extreme cases which could occur in any location but with a low probability of occurrence. In special cases situations will arise where the level of disturbances could exceed the levels specified in this document, e.g. where a hand-held transmitter is used in proximity of an apparatus. In these instances special mitigation measures might have to be employed.
It does not specify immunity of MCE to signals from other MCE operating in the same nominal frequency band or immunity to signals originating from power line carrier systems operating on high or medium-voltage networks.
Safety considerations are not included in this document.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-2-4:2024 is related to conducted disturbances in the frequency range from 0 kHz to 150 kHz. It gives compatibility levels in differential mode (L-L and L-N) for industrial locations, with a nominal voltage up to 35 kV and a nominal frequency of 50 Hz or 60 Hz.
NOTE 1 Industrial locations are defined in 3.1.8.
Power distribution systems on ships, aircraft, offshore platforms and railways are not included.
NOTE 2 See also Annex E. The compatibility levels specified in this document apply at the in-plant point of coupling (IPC). The level of the low-frequency disturbances at the terminals of equipment receiving its supply from the IPC is generally assumed to be similar to the disturbance level at the IPC itself. However, in some situations this is not the case, particularly when a long feeder is dedicated to the supply of a particular load, or when a disturbance is generated or amplified within the installation of which the equipment forms a part.
Compatibility levels are specified for the types of low-frequency electromagnetic disturbances expected at any in-plant point of coupling (IPC) within industrial locations, for guidance in the definition of:
a) limits for disturbance emissions in industrial power distribution systems (including the planning levels defined in 3.1.5);
NOTE 3 A very wide range of conditions is possible in the electromagnetic environments of industrial networks. These are approximated in this document by the three classes described in Clause 4. However, it is the responsibility of the operator of such a network to take account of the particular electromagnetic and economic conditions, including equipment characteristics, in setting the above-mentioned limits.
b) immunity levels for the equipment within these systems.
The disturbance phenomena considered are:
- voltage deviations;
- voltage dips and short interruptions;
- voltage imbalance;
- power-frequency variations;
- harmonics up to order 40;
- interharmonics up to the 40th harmonic;
- voltage components above the 40th harmonic up to 150 kHz;
- DC component;
- transient overvoltages.
The compatibility levels are given for different classes of environment determined by the characteristics of the supply network and loads.
NOTE 4 Compatibility levels at the point of common coupling (PCC) on public networks are specified in IEC 61000‑2‑2 for low-voltage networks and IEC 61000‑2‑12 for medium-voltage networks. IEC TR 61000‑3‑6 and IEC TR 61000‑3‑7 describe the approach of power distribution system operators to the limitation of emissions from installations and large loads.
This third edition cancels and replaces the second edition published in 2002. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) introduction of new classes 2a, 2b and 2L (former class 2);
b) modification of existing compatibility levels for class 3;
c) addition of compatibility levels in the frequency range 2 kHz to 150 kHz;
d) addition of compatibility levels using a new quantity: partial weighted harmonic distortion (PWHD).

  • Standard
    150 pages
    English language
    sale 15% off
  • Standard
    96 pages
    English and French language
    sale 15% off

This document specifies methods for testing the immunity of passenger cars and commercial vehicles to electromagnetic disturbances from on-board transmitters connected to an external antenna and portable transmitters with integral antennas, regardless of the vehicle propulsion system (e.g. spark ignition engine, diesel engine, electric motor).

  • Standard
    51 pages
    English language
    sale 15% off

This document specifies transverse electromagnetic (TEM) cell tests for determining the immunity of electronic components of passenger cars and commercial vehicles to electrical disturbances from narrowband radiated electromagnetic energy, regardless of the vehicle propulsion system (e.g. spark-ignition engine, diesel engine, electric motor). The electromagnetic disturbances considered are limited to continuous narrowband electromagnetic fields.

  • Standard
    21 pages
    English language
    sale 15% off

IEC TS 60601-4-6:2024 provides practical methods to help achieve basic safety and essential performance with regard to the possible effects of em disturbances throughout the expected service life of me equipment or an me system.
These practical methods attempt to address all of the different types of errors, malfunctions or failures that can be caused by em disturbances in me equipment or me systems.
The purpose of this document is to provide recommendations for the techniques and measures used in the design, verification, and validation of systems, hardware, software, and firmware used in me equipment or me systems to help achieve basic safety and essential performance with regard to the em disturbances that could occur throughout the expected service life.

  • Technical specification
    126 pages
    English language
    sale 15% off

IEC TS 60601-4-2:2024 applies to the performance of MEDICAL ELECTRICAL EQUIPMENT or a MEDICAL ELECTRICAL SYSTEM in the presence of EM DISTURBANCES. Hereafter, MEDICAL ELECTRICAL EQUIPMENT or a MEDICAL ELECTRICAL SYSTEM are referred to as ME EQUIPMENT or an ME SYSTEM, respectively.
The object of this document is to provide guidance on the assessment of the performance of ME EQUIPMENT or an ME SYSTEM in the presence of EM DISTURBANCES.
IEC TS 60601-4-2:2024 cancels and replaces the first edition of IEC TR 60601-4-2 published in 2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to IEC TR 60601-4-2:2016:
a) aligned with IEC 60601-1-2:2014 and IEC 60601-1-2:2014/AMD1:2020,
b) updated references,
c) changed conducted disturbance cable length exclusion (Table 6) from 3 m to 1 m and added a citation of IEC 61000-4-6:2013, Annex B.

  • Technical specification
    58 pages
    English language
    sale 15% off
  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61000 relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 150 kHz up to 80 MHz.
NOTE 1 Product committees might decide to use the methods described in this document also for frequencies up to 230 MHz (see Annex B) although the methods and test instrumentation is intended to be used in the frequency range up to 80 MHz.
Equipment not having at least one conducting wire and/or cable (such as mains supply, signal line or earth connection) which can couple the equipment to the disturbing RF fields is excluded from the scope of this publication.
NOTE 2 Test methods are specified in this part of IEC 61000 to assess the effect that conducted disturbing signals, induced by electromagnetic radiation, have on the equipment concerned. The simulation and measurement of these conducted disturbances are not adequately exact for the quantitative determination of effects. The test methods specified are structured for the primary objective of establishing adequate repeatability of results at various facilities for quantitative analysis of effects.
The object of this standard is to establish a common reference for evaluating the functional immunity of electrical and electronic equipment when subjected to conducted disturbances induced by RF fields. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a specified phenomenon.
NOTE 3 As described in IEC Guide 107, this standard is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria.

  • Standard
    86 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61000 relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 150 kHz up to 80 MHz. NOTE 1 Product committees might decide to use the methods described in this document also for frequencies up to 230 MHz (see Annex B) although the methods and test instrumentation is intended to be used in the frequency range up to 80 MHz. Equipment not having at least one conducting wire and/or cable (such as mains supply, signal line or earth connection) which can couple the equipment to the disturbing RF fields is excluded from the scope of this publication. NOTE 2 Test methods are specified in this part of IEC 61000 to assess the effect that conducted disturbing signals, induced by electromagnetic radiation, have on the equipment concerned. The simulation and measurement of these conducted disturbances are not adequately exact for the quantitative determination of effects. The test methods specified are structured for the primary objective of establishing adequate repeatability of results at various facilities for quantitative analysis of effects. The object of this standard is to establish a common reference for evaluating the functional immunity of electrical and electronic equipment when subjected to conducted disturbances induced by RF fields. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a specified phenomenon. NOTE 3 As described in IEC Guide 107, this standard is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria.

  • Standard
    86 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

CISPR 16-2-3:2016 specifies the methods of measurement of radiated disturbance phenomena in the frequency range of 9 kHz to 18 GHz. The aspects of measurement uncertainty are specified in CISPR 16-4-1 and CISPR 16-4-2. It has the status of a basic EMC publication in accordance with IEC Guide 107, "Electromagnetic compatibility - Guide to the drafting of electromagnetic compatibility publications". This fourth edition edition cancels and replaces the third edition published in 2010, its Amendment 1:2010 and its Amendment 2:2014. This edition constitutes a technical revision.

  • Standard
    317 pages
    English language
    sale 15% off
  • Standard
    213 pages
    English and French language
    sale 15% off
  • Standard
    507 pages
    English and French language
    sale 15% off
  • Standard
    525 pages
    English and French language
    sale 15% off

IEC 61000-4-6: 2023 relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 150 kHz up to 80 MHz.
NOTE 1 Product committees might decide to use the methods described in this document also for frequencies up to 230 MHz (see Annex B) although the methods and test instrumentation are intended to be used in the frequency range up to 80 MHz.
Equipment not having at least one conducting wire or cable (such as mains supply, signal line or earth connection) which can couple the equipment to the disturbing RF fields is excluded from the scope of this document.
NOTE 2 Test methods are specified in this part of IEC 61000 to assess the effect that conducted disturbing signals, induced by electromagnetic radiation, have on the equipment concerned. The simulation and measurement of these conducted disturbances are not adequately exact for the quantitative determination of effects. The test methods specified are structured for the primary objective of establishing adequate repeatability of results at various facilities for quantitative analysis of effects.
The object of this document is to establish a common reference for evaluating the functional immunity of electrical and electronic equipment when subjected to conducted disturbances induced by RF fields. The test method in this document describes a consistent method to assess the immunity of an equipment or system against a specified phenomenon.
NOTE 3 As described in IEC Guide 107, this document is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria.
This fifth edition cancels and replaces the fourth edition published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) selection of injection devices revised;
b) need of AE impedance check for clamp injection removed and Annex H deleted;
c) saturation check revised;
d) new Annex H on testing with multiple signals;
e) level-setting only with feedback loop.

  • Standard
    83 pages
    English language
    sale 15% off
  • Standard
    189 pages
    English language
    sale 15% off
  • Standard
    184 pages
    English and French language
    sale 15% off

This document specifies methods for testing the immunity of passenger cars and commercial vehicles to electromagnetic disturbances, regardless of the vehicle propulsion system (e.g. spark ignition engine, diesel engine, electric motor) using a reverberation chamber. The electromagnetic disturbances considered are limited to narrowband electromagnetic fields. While this document refers specifically to passenger cars and commercial vehicles, generalized as “vehicle(s)”, it can readily be applied to other types of vehicles. ISO 11451-1 specifies general test conditions, definitions, practical use, and basic principles of the test procedure. Function performance status classification guidelines for immunity to electromagnetic radiation from an off-vehicle radiation source are given in Annex A.

  • Standard
    87 pages
    English language
    sale 15% off

CISPR 36:2020 defines limits for 3 m measurement distance and methods of measurement that are designed to provide protection for off-board receivers (at 10 m distance) in the frequency range of 150 kHz to 30 MHz when used in the residential environment.
NOTE Protection of receivers used on board the same vehicle as the disturbance source(s) is covered by CISPR 25.
This document applies to the emission of electromagnetic energy which might cause interference to radio reception and which is emitted from electric and hybrid electric vehicles propelled by an internal traction battery (see 3.2 and 3.3) when operated on the road. This document applies to vehicles that have a traction battery voltage between 100 V and 1 000 V.
Electric vehicles to which CISPR 14-1 applies are not in the scope of this document. This document applies only to road vehicles where an electric propulsion is used for sustained speed of more than 6 km/h. Vehicles where the electric motor is only used to start up the internal combustion engine (e.g. "micro hybrid") and vehicles where the electric motor is used for additional propulsion only during acceleration (e.g. "48 V mild hybrid vehicles") are not in the scope of this document. The radiated emission requirements in this document are not applicable to the intentional transmissions from a radio transmitter as defined by the ITU including their spurious emissions. Annex C lists work being considered for future revisions.

  • Standard
    48 pages
    English and French language
    sale 15% off
  • Standard
    104 pages
    English and French language
    sale 15% off