SC 62A - Common aspects of medical equipment, software, and systems
- Abstract
To prepare international standards and other publications concerning the common aspects of the design, development, installation and application of medical equipment, software, and systems.
- Slovenian
Aspects communs des équipements, logiciels et systèmes médicaux
Etablir des normes internationales et d'autres publications relatives aux aspects communs des équipements, logiciels et systèmes médicaux.
ISO TS 24971-2:2026 This document provides guidance on risks specific to artificial intelligence (AI) and machine learning (ML) and how to apply the risk management process of ISO 14971 to ML-enabled medical devices (MLMD). This document is intended to be used in conjunction with ISO 14971 and ISO/TR 24971[2].
This document does not apply to MLMD employing large language models (LLM) or generative AI.
- Technical specification32 pagesEnglish languagesale 15% off
IEC TS 81001-2-2:2025 presents an informative set of common, high-level security-related capabilities and additional considerations to be used across the life cycle of health software and health IT systems, for the information exchange between the health software manufacturers (including medical device manufacturers), healthcare delivery organizations (HDOs) and other stakeholders. It is applicable to health software running on any platform and in any environment such as cloud, on premise or hybrid.
While important security topics, the following are outside the scope of this document:
a) the security policies of the HDO,
b) the product and services security policies of the manufacturer,
c) determinations of risk tolerance by the HDO or manufacturer, and
d) clinical studies where there is a need to secure personal data.
As security risks can be caused by any product on health IT systems and health IT Infrastructure, considerations in this document can be applied for other products that are not health software.
IEC TS 81001-2-2:2025 withdraws and replaces:
– IEC TR 80001-2-2, Application of risk management for IT-networks incorporating medical devices – Part 2-2: Guidance for the communication of medical device security needs, risks and controls
– IEC TR 80001-2-8, Application of risk management for IT-networks incorporating medical devices – Part 2-8: Application guidance – Guidance on standards for establishing the security capabilities identified in IEC TR 80001-2-2
This document includes the following significant changes:
a) Combines and updates the contents of IEC TR 80001-2-2 and IEC TR 80001-2-8;
b) Extends the scope to health software instead to only medical device software;
c) Aligns contents and definitions to ISO 81001-1:2021 and the updated IEC 80001-1;
d) Removed the Configuration of Security Features (CNFS) capability, as any configurable security capability shall be clearly communicated.
e) Provide security control mappings to several new standards, e.g. IEC TR 60601-4-5, IEC 62443-4-2, ISO/IEEE 11073-40102 and the recent versions of previous standards, e.g. ISO/IEC 27002 and NIST 800-53 version 5.
- Technical specification103 pagesEnglish languagesale 15% off
This document establishes requirements and gives guidance on assurance case framework for healthcare delivery organizations (HDOs) and for health software and medical device manufacturers (MDMs) and can be used to support the communication and information transfer between all parties. An assurance case can be used to communicate information and knowledge about different risks to other roles.
This document establishes:
- an assurance case framework for HDOs and health software and MDMs for identifying, developing, interpreting, updating and maintaining assurance cases.
- one of the possible means to bridge the gap between manufacturers and HDOs in providing adequate information to support the HDOs risk management of IT-networks;
- best practice by leveraging ISO/IEC/IEEE 15026-2 and other standards to identify key considerations and for the structure and contents of an assurance case, e.g. iterative and continuous approaches;
- example structure, method and format to improve the consistency and comparability of assurance cases.
This document is applicable to all parties involved in the health software and health IT systems life cycle, including:
a) organizations, health informatics professionals and clinical leaders specifying, acquiring, designing, developing, integrating, implementing and operating health software and health IT systems, for example health software developers and MDMs, system integrators, system administrators (including cloud and other IT service providers);
b) healthcare service delivery organizations, healthcare providers and others who use health software and health IT systems in providing health services;
c) governments, health system funders, monitoring agencies, professional organizations and customers seeking confidence in an organization’s ability to consistently provide safe, effective and secure health software, health IT systems and services;
d) organizations and interested parties seeking to improve communication in managing safety, effectiveness and security risks through a common understanding of the concepts and terminology used in safety, effectiveness and security management;
e) providers of training, assessment or advice in safety, effectiveness and security risk management for health software and health IT systems;
f) developers of related safety, effectiveness and security standards.
This document is for use by organizations and people who build, acquire, operate, maintain, use or decommission health software and health IT systems (including medical devices). It is applicable to all organizations involved, regardless of size, complexity or business model.
- Technical specification46 pagesEnglish languagesale 15% off
IEC TS 60601-4-6:2024 provides practical methods to help achieve basic safety and essential performance with regard to the possible effects of em disturbances throughout the expected service life of me equipment or an me system.
These practical methods attempt to address all of the different types of errors, malfunctions or failures that can be caused by em disturbances in me equipment or me systems.
The purpose of this document is to provide recommendations for the techniques and measures used in the design, verification, and validation of systems, hardware, software, and firmware used in me equipment or me systems to help achieve basic safety and essential performance with regard to the em disturbances that could occur throughout the expected service life.
- Technical specification126 pagesEnglish languagesale 15% off
IEC TS 60601-4-2:2024 applies to the performance of MEDICAL ELECTRICAL EQUIPMENT or a MEDICAL ELECTRICAL SYSTEM in the presence of EM DISTURBANCES. Hereafter, MEDICAL ELECTRICAL EQUIPMENT or a MEDICAL ELECTRICAL SYSTEM are referred to as ME EQUIPMENT or an ME SYSTEM, respectively.
The object of this document is to provide guidance on the assessment of the performance of ME EQUIPMENT or an ME SYSTEM in the presence of EM DISTURBANCES.
IEC TS 60601-4-2:2024 cancels and replaces the first edition of IEC TR 60601-4-2 published in 2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to IEC TR 60601-4-2:2016:
a) aligned with IEC 60601-1-2:2014 and IEC 60601-1-2:2014/AMD1:2020,
b) updated references,
c) changed conducted disturbance cable length exclusion (Table 6) from 3 m to 1 m and added a citation of IEC 61000-4-6:2013, Annex B.
- Technical specification58 pagesEnglish languagesale 15% off
- Technical report3 pagesEnglish languagesale 15% off
- Standard3 pagesEnglish and French languagesale 15% off
IEC TR 60878:2022 provides a compilation, for easy reference, of graphical symbols (graphics, title, description) and safety signs for medical electrical equipment. The graphical symbols are grouped in sections according to their specific field of application (see Clause 4).
IEC TR 60878:2022 cancels and replaces the third edition published in 2015. This fourth edition constitutes a technical revision.
The main changes compared with IEC TR 60878:2015 are as follows:
• A total of 109 new symbols and safety signs that have been identified since the publication of the third edition have been added. For identification, the number of the new symbol or safety sign is printed in red followed by “New”.
• Of the symbols and safety signs in the third edition, 14 have changes in their title or description. For identification, the number of a modified symbol or safety sign is printed in red followed by “Mod”.
The contents of the corrigendum of February 2023 have been included in this copy.
- Technical report226 pagesEnglish languagesale 15% off
This document defines the LIFE CYCLE requirements for development and maintenance of HEALTH SOFTWARE needed to support conformance to IEC 62443-4-1[11] – taking the specific needs for HEALTH SOFTWARE into account. The set of PROCESSES, ACTIVITIES, and TASKS described in this document establishes a common framework for secure HEALTH SOFTWARE LIFE CYCLE PROCESSES. An informal overview of activities for HEALTH SOFTWARE is shown in Figure 2. [Figure 2] [derived from IEC 62304:2006[8], Figure 2] Figure 2 - HEALTH SOFTWARE LIFE CYCLE PROCESSES The purpose is to increase the CYBERSECURITY of HEALTH SOFTWARE by establishing certain ACTIVITIES and TASKS in the HEALTH SOFTWARE LIFE CYCLE PROCESSES and also by increasing the SECURITY of SOFTWARE LIFE CYCLE PROCESSES themselves. It is important to maintain an appropriate balance of the key properties SAFETY, effectiveness and SECURITY as discussed in ISO 81001-1[17]. This document excludes specification of ACCOMPANYING DOCUMENTATION contents.
- Standard59 pagesEnglish languagee-Library read for
CORRECTED VERSION 2025-12
IEC 81001-5-1:2021 defines the LIFE CYCLE requirements for development and maintenance of HEALTH SOFTWARE needed to support conformance to IEC 62443-4-1 – taking the specific needs for HEALTH SOFTWARE into account. The set of PROCESSES, ACTIVITIES, and TASKS described in this document establishes a common framework for secure HEALTH SOFTWARE LIFE CYCLE PROCESSES.
The purpose is to increase the CYBERSECURITY of HEALTH SOFTWARE by establishing certain ACTIVITIES and TASKS in the HEALTH SOFTWARE LIFE CYCLE PROCESSES and also by increasing the SECURITY of SOFTWARE LIFE CYCLE PROCESSES themselves.
It is important to maintain an appropriate balance of the key properties SAFETY, effectiveness and SECURITY as discussed in ISO 81001-1.
This document excludes specification of ACCOMPANYING DOCUMENTATION contents.
The contents of the Interpretation sheet 1 (2025-12) have been included in this copy.
- Standard114 pagesEnglish and French languagesale 15% off
This document specifies general requirements for ORGANIZATIONS in the application of RISK MANAGEMENT before, during and after the connection of a HEALTH IT SYSTEM within a HEALTH IT INFRASTRUCTURE, by addressing the KEY PROPERTIES of SAFETY, EFFECTIVENESS and SECURITY whilst engaging appropriate stakeholders.
- Standard39 pagesEnglish languagee-Library read for
2021-08-25-JO: BT Decision (BT169/DG12292/DV) to remove the link to the MDR
2021-06-24: blocked so that the link to the MDD can be removed by BT from the document
2019-12-03-JO-Assessment at ENQ uplaoded with due date of 06 Jan.2020 plus extention requested by HAS Consultant
- Amendment58 pagesEnglish languagee-Library read for
This document specifies general requirements for ORGANIZATIONS in the application of RISK MANAGEMENT before, during and after the connection of a HEALTH IT SYSTEM within a HEALTH IT INFRASTRUCTURE, by addressing the KEY PROPERTIES of SAFETY, EFFECTIVENESS and SECURITY whilst engaging appropriate stakeholders. IEC 80001-1:2021 cancels and replaces the first edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) structure changed to better align with ISO 31000; b) establishment of requirements for an ORGANIZATION in the application of RISK MANAGEMENT; c) communication of the value, intention and purpose of RISK MANAGEMENT through principles that support preservation of the KEY PROPERTIES during the implementation and use of connected HEALTH SOFTWARE and/or HEALTH IT SYSTEMS.
- Standard75 pagesEnglish and French languagesale 15% off
- Draft31 pagesEnglish languagesale 15% off
IEC 80001-1:2021 specifies general requirements for ORGANIZATIONS in the application of RISK MANAGEMENT before, during and after the connection of a HEALTH IT SYSTEM within a HEALTH IT INFRASTRUCTURE, by addressing the KEY PROPERTIES of SAFETY, EFFECTIVENESS and SECURITY whilst engaging appropriate stakeholders.
IEC 80001-1:2021 cancels and replaces the first edition published in 2010. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) structure changed to better align with ISO 31000;
b) establishment of requirements for an ORGANIZATION in the application of RISK MANAGEMENT;
c) communication of the value, intention and purpose of RISK MANAGEMENT through principles that support preservation of the KEY PROPERTIES during the implementation and use of connected HEALTH SOFTWARE and/or HEALTH IT SYSTEMS.
- Standard75 pagesEnglish and French languagesale 15% off
This document provides quality requirements for health apps and defines a health app quality label in order to visualize the quality and reliability of health apps.
This document is applicable to health apps, which are a special form of health software. It covers the entire life cycle of health apps.
This document is intended for use by app manufacturers as well as app assessment organizations in order to communicate the quality and reliability of a health app. Consumers, patients, carers, health care professionals and their organizations, health authorities, health insurers and the wider public can use the health app quality label and report when recommending or selecting a health app for use, or for adoption in care guidelines, care pathways and care contracts.
NOTE 1 Health apps can be subject to national legislation, such as for medical devices.
NOTE 2 See Annex C for additional details on the scope.
Outside the scope of this document are guidelines to comply to the medical device regulation.
- Technical specification78 pagesEnglish languagesale 15% off
This document provides quality requirements for health apps and defines a health app quality label in order to visualize the quality and reliability of health apps. This document is applicable to health apps, which are a special form of health software. It covers the entire life cycle of health apps. This document is intended for use by app manufacturers as well as app assessment organizations in order to communicate the quality and reliability of a health app. Consumers, patients, carers, health care professionals and their organizations, health authorities, health insurers and the wider public can use the health app quality label and report when recommending or selecting a health app for use, or for adoption in care guidelines, care pathways and care contracts. NOTE 1 Health apps can be subject to national legislation, such as for medical devices. NOTE 2 See Annex C for additional details on the scope. Outside the scope of this document are guidelines to comply to the medical device regulation.
- Technical specification78 pagesEnglish languagesale 15% off
- Technical specification78 pagesEnglish languagesale 15% off
2020-11-16_JO_BT167/DG11868/DV to remove the link to (MDD 93/42/EEC) and M/295
- Amendment12 pagesEnglish languagee-Library read for
2020-11-16_JO_BT167/DG11868/DV to remove the link to (MDD 93/42/EEC) and M/432
- Amendment61 pagesEnglish languagee-Library read for
2020-11-16_JO_BT167/DG11868/DV to remove the link to (MDD 93/42/EEC) , 90/385/EEC (AIMD) and M/295
- Amendment12 pagesEnglish languagee-Library read for
2020-11-16_JO_BT167/DG11868/DV to remove the link to (MDD 93/42/EEC) and M/432
- Amendment14 pagesEnglish languagee-Library read for
This document provides the principles, concepts, terms and definitions for health software and health IT systems, key properties of safety, effectiveness and security, across the full life cycle, from concept to decommissioning, as represented in Figure 1. It also identifies the transition points in the life cycle where transfers of responsibility occur, and the types of multi-lateral communication that are necessary at these transition points. This document also establishes a coherent concepts and terminology for other standards that address specific aspects of the safety, effectiveness, and security (including privacy) of health software and health IT systems.
This document is applicable to all parties involved in the health software and health IT systems life cycle including the following:
a) Organizations, health informatics professionals and clinical leaders designing, developing, integrating, implementing and operating health software and health IT systems â for example health software developers and medical device manufacturers, system integrators, system administrators (including cloud and other IT service providers);
b) Healthcare service delivery organizations, healthcare providers and others who use health software and health IT systems in providing health services;
c) Governments, health system funders, monitoring agencies, professional organizations and customers seeking confidence in an organizationâs ability to consistently provide safe, effective and secure health software, health IT systems and services;
d) Organizations and interested parties seeking to improve communication in managing safety, effectiveness and security risks through a common understanding of the concepts and terminology used in safety, effectiveness and security management;
e) Providers of training, assessment or advice in safety, effectiveness and security risk management for health software and health IT systems;
f) Developers of related safety, effectiveness and security standards.
- Standard61 pagesEnglish languagesale 15% off
2020-11-16_JO_BT167/DG11868/DV to remove the link to (MDD 93/42/EEC) and M/295
- Amendment36 pagesEnglish languagee-Library read for
IEC TR 60601-4-5:2021 provides detailed technical specifications for SECURITY features of MEDICAL DEVICES used in MEDICAL IT-NETWORKS. MEDICAL DEVICES dealt with in this document include MEDICAL ELECTRICAL EQUIPMENT, MEDICAL ELECTRICAL SYSTEMS and MEDICAL DEVICE SOFTWARE. MEDICAL DEVICE SOFTWARE, although not in the scope of IEC 60601 (all parts), can also make use of this document. Based on the seven foundational requirements described in the state-of-the-art document IEC TS 62443 1 1:2009, this document provides specifications for different MEDICAL DEVICE capability SECURITY LEVELS (SL C). The specified SECURITY capabilities of a MEDICAL DEVICE can be used by various members of the medical community to integrate the device correctly into defined SECURITY ZONES and CONDUITS of a MEDICAL IT-NETWORK with an appropriate MEDICAL IT NETWORK's target SECURITY LEVEL (SL T).
This document is applicable to MEDICAL DEVICES with external data interface(s), for example when connected to a MEDICAL IT-NETWORK or when a human interface is used for processing – e.g. entering, capturing or viewing – CONFIDENTIAL DATA.
This document does not apply to other software used on a MEDICAL IT-NETWORK which does not meet the definition of MEDICAL DEVICE SOFTWARE.
This document does not apply to in-vitro diagnostic devices (IVD).
- Technical report51 pagesEnglish languagesale 15% off
2020-10-13_JO_CLC/TC 62 Decision 2019-05-21/22 in Oslo to remove the link to the published standard
- Amendment7 pagesEnglish languagee-Library read for
2020-10-13:JO-CLC/TC 62 Decision 2019-05-21/22 in Oslo to remove the link to the published standard
- Amendment9 pagesEnglish languagee-Library read for
- Standard32 pagesEnglish languagesale 15% off
- Standard65 pagesEnglish and French languagesale 15% off
IEC 60601-1-2:2014 applies to the basic safety and essential performance of Medical Equipment (ME) equipment and ME systems in the presence of electromagnetic disturbances and to electromagnetic disturbances emitted by me equipment and me systems. This collateral standard to IEC 60601-1 specifies general requirements and tests for basic safety and essential performance with regard to electromagnetic disturbances and for electromagnetic emissions of ME equipment and ME systems. They are in addition to the requirements of the general standard IEC 60601-1 and serve as the basis for particular standards. This fourth edition cancels and replaces the third edition of IEC 60601-1-2, and constitutes a technical revision. The most significant changes with respect to the previous edition include the following modifications:
- specification of immunity test levels according to the environments of intended use, categorized according to locations that are harmonized with IEC 60601-1-11: the professional healthcare facility environment, the home healthcare environment and special environments;
- specification of tests and test levels to improve the safety of medical electrical equipment and medical electrical systems when portable RF communications equipment is used closer to the medical electrical equipment than was recommended based on the immunity test levels that were specified in the third edition;
- specification of immunity tests and immunity test levels according to the ports of the medical electrical equipment or medical electrical system;
- specification of immunity test levels based on the reasonably foreseeable maximum level of electromagnetic disturbances in the environments of intended use, resulting in some immunity test levels that are higher than in the previous edition; and
- better harmonization with the risk concepts of basic safety and essential performance, including deletion of the defined term "life-supporting". This new edition includes the following main additions:
- guidance for determination of immunity test levels for special environments;
- guidance for adjustment of immunity test levels when special considerations of mitigations or intended use are applicable;
- guidance on risk management for basic safety and essential performance with regard to electromagnetic disturbances; and
- guidance on identification of immunity pass/fail criteria.
- Standard216 pagesEnglish languagesale 15% off
- Standard188 pagesEnglish and French languagesale 15% off
- Standard456 pagesEnglish and French languagesale 15% off
IEC 60601-1:2005 contains requirements concerning basic safety and essential performance that are generally applicable to medical electrical equipment. For certain types of medical electrical equipment, these requirements are either supplemented or modified by the special requirements of a collateral or particular standard. Where particular standards exist, this standard should not be used alone. The contents of the corrigenda of December 2006, December 2007 and December 2022, the interpretation sheets of April 2008, January 2009 and May 2013 have been included in this copy.
- Standard10 pagesEnglish languagesale 15% off
- Standard842 pagesEnglish languagesale 15% off
- Standard803 pagesEnglish languagesale 15% off
- Standard777 pagesEnglish and French languagesale 15% off
- Standard1740 pagesEnglish and French languagesale 15% off
- Standard1660 pagesEnglish and French languagesale 15% off
- Standard51 pagesEnglish languagesale 15% off
- Standard104 pagesEnglish and French languagesale 15% off
2019-04-04-JO-: link to legislation to the MDD 93/42/EEC and mandate M/432 removed following CLC/BT decision D162/C076
- Amendment22 pagesEnglish languagee-Library read for
- Standard58 pagesEnglish languagesale 15% off
- Standard119 pagesEnglish and French languagesale 15% off
Specifies basic safety and essential performance requirements and tests for alarm systems in medical electrical equipment and medical electrical systems and to provide guidance for their application. This is accomplished by defining alarm categories (priorities) by degree of urgency, consistent alarm signals and consistent control states and their marking for all alarm systems.
- Standard254 pagesEnglish languagesale 15% off
- Standard157 pagesEnglish and French languagesale 15% off
- Standard186 pagesEnglish and French languagesale 15% off
- Standard522 pagesEnglish and French languagesale 15% off
IEC 60601-1-11:2015 applies to the basic safety and essential performance of medical electrical equipment and medical electrical systems for use in the home healthcare environment. It applies regardless of whether the medical electrical equipment or medical electrical system is intended for use by a lay operator or by trained healthcare personnel. The home healthcare environment includes:
- the dwelling place in which a patient lives;
- other places where patients are present both indoors and outdoors, excluding professional healthcare facility environments where operators with medical training are continually available when patients are present.
This second edition cancels and replaces the first edition of IEC 60601-1-11, published in 2010, and constitutes a technical revision. The most significant changes with respect to the previous edition include the following modifications:
- correction of test method for relative humidity control at temperatures above 35 °C;
- redrafting of subclauses that altered instead of adding to the general standard or other collateral standards; and
- harmonizing with the changes to the amendments to the general standard and other collateral standards.
- Standard190 pagesEnglish languagesale 15% off
- Standard257 pagesEnglish and French languagesale 15% off
- Standard125 pagesEnglish and French languagesale 15% off
- Standard21 pagesEnglish and French languagesale 15% off
- Standard9 pagesEnglish and French languagesale 15% off
- Standard18 pagesEnglish and French languagesale 15% off
- Standard16 pagesEnglish and French languagesale 15% off
IEC 60601-1-6:2010 specifies a process for a manufacturer to analyse, specify, design, verify and validate usability, as it relates to basic safety and essential performance of medical electrical equipment. This usability engineering process assesses and mitigates risks caused by usability problems associated with correct use and use errors, i.e., normal use. It can be used to identify but does not assess or mitigate risks associated with abnormal use. If the usability engineering process detailed in this collateral standard has been complied with and the acceptance criteria documented in the usability validation plan have been met (see 5.9 of IEC 62366:2007), then the residual risks, as defined in ISO 14971, associated with usability of me equipment are presumed to be acceptable, unless there is objective evidence to the contrary (see 4.1.2 of IEC 62366:2007). The object of this collateral standard is to specify general requirements that are in addition to those of the general standard and to serve as the basis for particular standards. This document cancels and replaces the second edition of IEC 60601-1-6 which has been technically revised. It was revised to align with the usability engineering process in IEC 62366. To allow for equipment manufacturers and testing organizations to make products and to equip themselves for conducting revised tests in accordance with this third edition, it is recommended by SC 62A that the content of this document not be adopted for mandatory implementation earlier than 3 years from the date of publication for equipment newly designed and not earlier than 5 years from the date of publication for equipment already in production.
- Standard51 pagesEnglish and French languagesale 15% off
- Standard121 pagesEnglish and French languagesale 15% off
- Standard93 pagesEnglish and French languagesale 15% off
IEC 60601-1-12:2014 constitutes a collateral standard to IEC 60601-1: Medical electrical equipment - Part 1: General requirements for basic safety and essential performance hereafter referred to as the general standard. Medical practice is increasingly using medical electrical equipment and medical electrical systems for monitoring, treatment or diagnosis of patients in the emergency medical services environment. The safety of medical electrical equipment in this uncontrolled, rough environment is a cause for concern. This collateral standard was developed with contributions from clinicians, engineers and regulators. The terminology, requirements, general recommendations and guidance of this collateral standard are intended to be useful for manufacturers of medical electrical equipment and medical electrical systems and for technical committees responsible for the development of particular standards. This International Standard applies to the basic safety and essential performance of medical electrical equipment and medical electrical systems, hereafter referred to as ME equipment and ME systems, which are intended, as indicated in the instructions for use by their manufacturer, for use in the EMS environment (Emergency Medical Services environment). The object of this collateral standard is to provide general requirements for ME equipment and ME systems carried to the scene of an emergency and used there, as well as in transport, in situations where the ambient conditions differ from indoor conditions. The object of this collateral standard is to specify general requirements that are in addition to those of the general standard and to serve as the basis for particular standards.
- Standard101 pagesEnglish and French languagesale 15% off
- Standard202 pagesEnglish and French languagesale 15% off
Specifies requirements for the development (analysis, design, verification and validation) of a physiologic closed-loop controller (PCLC) as part of a physiologic closed-loop control system (PCLCS) in medical electrical equipment and medical electrical systems to control a physiologic variable. This collateral standard applies to various types of PCLC, e.g. linear and non-linear, adaptive, fuzzy, neural networks. This collateral standard applies to a closed-loop controller that sets the controller output variable in order to adjust (i.e., change or maintain) the measured physiologic variable by relating it to the reference variable.
- Standard79 pagesEnglish and French languagesale 15% off
- Standard164 pagesEnglish and French languagesale 15% off
- Standard173 pagesEnglish and French languagesale 15% off
IEC 60601-1-9:2007 The objective of this collateral standard is to improve the environmental impact for the entire range of medical electrical equipment, taking into account all stages of the product life cycle:
- product specification;
- design;
- manufacturing;
- sales, logistics, installation;
- use;
- end of life management. This means protecting the environment and human health from hazardous substances, conserving raw materials and energy, minimizing the generation of waste, as well as minimizing the adverse environmental impacts associated with waste. The criteria needed to reach this goal must be integrated into all stages of the medical electrical equipment life cycle from the specification stage to end of life management. The environmental impacts of me equipment through all life-cycle stages are determined from the medical electrical equipment's environmental aspects defined during the identification of need, product planning, and design stages. Consideration of environmental aspects as early as possible in these stages can produce numerous benefits that might include lower costs, stimulation of innovation and creativity, and increased knowledge about the product. It can also provide new business opportunities, and improved product quality as well as reduction of adverse environmental impacts. The assessment of the environmental aspects and impacts of medical electrical equipment is a developing science and it is anticipated that this collateral standard will require periodic updating as the science develops. The requirements given in this collateral standard do not replace national or international laws and regulations. Environmental protection is one element of the overall risk management process as required by the general standard. The acceptability of medical electrical equipment's environmental impacts are balanced against other factors, such as the product's intended function, performance, safety, cost, marketability, quality, legal and regulatory requirements. This balance can differ depending on the intended function of the medical electrical equipment. For example, a solution appropriate for life-saving or life-supporting medical electrical equipment might not be appropriate for a device intended to correct a minor ailment. A manufacturer of medical electrical equipment might have to justify, as a result of risk management, that a medical benefit outweighs the associated adverse environmental impacts.
- Standard60 pagesEnglish and French languagesale 15% off
- Standard61 pagesEnglish and French languagesale 15% off
- Standard122 pagesEnglish and French languagesale 15% off
- Standard38 pagesEnglish and French languagesale 15% off
IEC 62366-1:2015 specifies a process for a manufacturer to analyse, specify, develop and evaluate the usability of a medical device as it relates to safety. This usability engineering (human factors engineering) process permits the manufacturer to assess and mitigate risks associated with correct use and use errors, i.e., normal use. It can be used to identify but does not assess or mitigate risks associated with abnormal use. This first edition of IEC 62366-1, together with the first edition of IEC 62366-2 (not published yet), cancels and replaces the first edition of IEC 62366 published in 2007 and its Amendment 1:2014. Part 1 has been updated to include contemporary concepts of usability engineering, while also streamlining the process. It strengthens links to ISO 14971:2007 and the related methods of risk management as applied to safety related aspects of medical device user interfaces. Part 2, once published, will contain tutorial information to assist manufactures in complying with Part 1, as well as offering more detailed descriptions of usability engineering methods that can be applied more generally to medical devices that go beyond safety-related aspects of medical device user interfaces. The contents of the corrigendum of July 2016 have been included in this copy.
- Standard110 pagesEnglish and French languagesale 15% off
- Standard246 pagesEnglish and French languagesale 15% off
This document provides guidance on the development, implementation and maintenance of a risk management system for medical devices according to ISO 14971:2019.
The risk management process can be part of a quality management system, for example one that is based on ISO 13485:2016[24], but this is not required by ISO 14971:2019. Some requirements in ISO 13485:2016 (Clause 7 on product realization and 8.2.1 on feedback during monitoring and measurement) are related to risk management and can be fulfilled by applying ISO 14971:2019. See also the ISO Handbook: ISO 13485:2016 - Medical devices - A practical guide.
- Technical report87 pagesEnglish languagesale 15% off
This document specifies terminology, principles and a process for risk management of medical devices, including software as a medical device and in vitro diagnostic medical devices. The process described in this document intends to assist manufacturers of medical devices to identify the hazards associated with the medical device, to estimate and evaluate the associated risks, to control these risks, and to monitor the effectiveness of the controls.
The requirements of this document are applicable to all phases of the life cycle of a medical device. The process described in this document applies to risks associated with a medical device, such as risks related to biocompatibility, data and systems security, electricity, moving parts, radiation, and usability.
The process described in this document can also be applied to products that are not necessarily medical devices in some jurisdictions and can also be used by others involved in the medical device life cycle.
This document does not apply to:
- decisions on the use of a medical device in the context of any particular clinical procedure; or
- business risk management.
This document requires manufacturers to establish objective criteria for risk acceptability but does not specify acceptable risk levels.
Risk management can be an integral part of a quality management system. However, this document does not require the manufacturer to have a quality management system in place.
NOTE Guidance on the application of this document can be found in ISO/TR 24971[9].
- Standard36 pagesEnglish languagesale 15% off
- Standard36 pagesFrench languagesale 15% off
This document specifies terminology, principles and a process for risk management of medical devices, including software as a medical device and in vitro diagnostic medical devices. The process described in this document intends to assist manufacturers of medical devices to identify the hazards associated with the medical device, to estimate and evaluate the associated risks, to control these risks, and to monitor the effectiveness of the controls. The requirements of this document are applicable to all phases of the life cycle of a medical device. The process described in this document applies to risks associated with a medical device, such as risks related to biocompatibility, data and systems security, electricity, moving parts, radiation, and usability. The process described in this document can also be applied to products that are not necessarily medical devices in some jurisdictions and can also be used by others involved in the medical device life cycle. This document does not apply to: — decisions on the use of a medical device in the context of any particular clinical procedure; or — business risk management. This document requires manufacturers to establish objective criteria for risk acceptability but does not specify acceptable risk levels. Risk management can be an integral part of a quality management system. However, this document does not require the manufacturer to have a quality management system in place. NOTE Guidance on the application of this document can be found in ISO/TR 24971[9].
- Standard36 pagesEnglish languagesale 15% off
- Standard36 pagesEnglish languagesale 15% off
- Standard39 pagesFrench languagesale 15% off
- Standard39 pagesFrench languagesale 15% off
- Standard39 pagesSpanish languagesale 15% off
IEC 60601-1-2:2014 applies to the basic safety and essential performance of Medical Equipment (ME) equipment and ME systems in the presence of electromagnetic disturbances and to electromagnetic disturbances emitted by me equipment and me systems. This collateral standard to IEC 60601-1 specifies general requirements and tests for basic safety and essential performance with regard to electromagnetic disturbances and for electromagnetic emissions of ME equipment and ME systems. They are in addition to the requirements of the general standard IEC 60601-1 and serve as the basis for particular standards. This fourth edition cancels and replaces the third edition of IEC 60601-1-2, and constitutes a technical revision. The most significant changes with respect to the previous edition include the following modifications: - specification of immunity test levels according to the environments of intended use, categorized according to locations that are harmonized with IEC 60601-1-11: the professional healthcare facility environment, the home healthcare environment and special environments; - specification of tests and test levels to improve the safety of medical electrical equipment and medical electrical systems when portable RF communications equipment is used closer to the medical electrical equipment than was recommended based on the immunity test levels that were specified in the third edition; - specification of immunity tests and immunity test levels according to the ports of the medical electrical equipment or medical electrical system; - specification of immunity test levels based on the reasonably foreseeable maximum level of electromagnetic disturbances in the environments of intended use, resulting in some immunity test levels that are higher than in the previous edition; and - better harmonization with the risk concepts of basic safety and essential performance, including deletion of the defined term 'life-supporting'. This new edition includes the following main additions: - guidance for determination of immunity test levels for special environments; - guidance for adjustment of immunity test levels when special considerations of mitigations or intended use are applicable; - guidance on risk management for basic safety and essential performance with regard to electromagnetic disturbances; and - guidance on identification of immunity pass/fail criteria.
- Standard99 pagesEnglish languagee-Library read for
Frequently Asked Questions
SC 62A is a Technical Committee within the International Electrotechnical Commission (IEC). It is named "Common aspects of medical equipment, software, and systems" and is responsible for: To prepare international standards and other publications concerning the common aspects of the design, development, installation and application of medical equipment, software, and systems. This committee has published 164 standards.
SC 62A develops IEC standards. The scope of work includes: To prepare international standards and other publications concerning the common aspects of the design, development, installation and application of medical equipment, software, and systems. Currently, there are 164 published standards from this technical committee.
The International Electrotechnical Commission (IEC) is the world's leading organization for the preparation and publication of international standards for electrical, electronic, and related technologies. Founded in 1906, the IEC provides a global platform for companies, industries, and governments to meet, discuss, and develop the international standards they require.
A Technical Committee (TC) in IEC is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.