29.080.01 - Electrical insulation in general
ICS 29.080.01 Details
Electrical insulation in general
Isolierung im allgemeinen
Isolation electrique en general
Električna izolacija na splošno
General Information
e-Library Subscription
Create subscription and get permanent access to documents within 29.080.01 - Electrical insulation in general
Currently subscription includes documents marked with .We are working on making all documents available within the subscription.
European common modification to EN 61936-1
- Draft16 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61557-9:2023 specifies the requirements for the insulation fault location system (IFLS) that localizes insulation faults in any part of the system in unearthed IT AC systems and unearthed IT AC systems with galvanically connected DC circuits having nominal voltages up to 1 000 V AC, as well as in unearthed IT DC systems with voltages up to 1 500 V DC, independent of the measuring principle. IEC 61557-9:2023 cancels and replaces the third edition published in 2014. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) new terms and definitions on maximum admissible locating AC and DC currents and voltages;
b) the requirements on locating current and locating voltage have been revised;
c) performance requirements have been added;
d) the test requirements for locating current and locating voltage have been revised;
e) the structure of this document has been adapted to that of IEC 61557-1:2019;
f) the limit values under Clause A.2 were adapted to fit the changed test methods in 6.2.3.
- Standard38 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61557-16:2023 specifies the requirements applicable to the performance for test and measurement equipment in order to determine the effectiveness of the protective measures for electrical equipment and/or medical electrical equipment described in IEC 62353.
This International Standard is to be used in conjunction with IEC 61557-1:2019.
IEC 61557-16:2023 cancels and replaces the first edition published in 2014. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) splitting of uncertainty requirements for medical and non-medical electrical equipment in 4.2.1;
b) addition of a definition of ranges with defined uncertainty in 4.2.1 to 4.2.7;
c) addition of an optional measuring device (MD) for non-medical devices in 4.2.1;
d) addition of a limitation of the maximum intrinsic uncertainty for medical applications at leakage current in 4.2.1;
e) change of 4.2.3 from test sockets to sockets for service purposes;
f) addition of a warning in the operating instructions;
g) integration of former 6.3 into 6.2;
h) update of Table 1;
i) alignment of the structure with that of the whole IEC 61557 series.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 61557 specifies the requirements for measuring equipment that combines several measuring functions or methods of testing, measuring or monitoring, that are in accordance with the respective parts of IEC 61557, into one piece of apparatus.
Measuring equipment which combines measuring functions or methods of testing, measuring or monitoring covered by the respective parts of IEC 61557 with those not covered by the respective parts of IEC 61557 is also within the scope of this document.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61557-14:2023 defines special requirements for test and measurement equipment used to determine the electrical safety of electrical equipment of machinery in accordance with IEC 60204-1.
This International Standard is to be used in conjunction with IEC 61557-1:2019.
IEC 61557-14:2023 cancels and replaces the first edition published in 2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) clarifying the introduction;
b) replaced "dielectric strength" by "voltage test";
c) requirement for maximum output current has been added in 4.2.6.1;
d) tripping time at electrical switching activated by two-hand operation has been added in 4.2.6.1;
e) additional time limiting capability for the protection against electric shock for test persons and bystanders in 4.2.6.2;
f) updated references for safety testing;
g) alignment of the structure with that of the whole IEC 61557 series.
- Standard20 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61557-13:2023 defines special performance requirements for hand-held and hand manipulated current clamps and sensors for measurement of leakage currents in electrical distribution systems up to 1 000 V AC and 1 500 V DC taking into account the influence of high external low-frequency magnetic fields and other influencing quantities. See Annex A for examples of measurement applications.
This document does not apply to current clamps or sensors that are used in combination with devices for insulation fault location in accordance with IEC 61557-9, unless it is specified by the manufacturer.
IEC 61557-13:2023 cancels and replaces the first edition published in 2011. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) the term "fixing device" has been removed;
b) the measuring range was changed to a display range, the indication of DC or peak values has been added in 4.1;
c) the frequency for the test of sensitivity for low-frequency magnetic fields has been defined in 4.2;
d) the specified measuring range is now defined as the range of indicated values based on the operating uncertainty in 4.3;
e) alignment of the structure with that of the whole IEC 61557 series;
f) the variation E12 (maximum load current), may be specified according to the manufacturer’s specification.
- Standard24 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 61557 specifies the requirements for measuring equipment that combines several measuring functions or methods of testing, measuring or monitoring, that are in accordance with the respective parts of IEC 61557, into one piece of apparatus. Measuring equipment which combines measuring functions or methods of testing, measuring or monitoring covered by the respective parts of IEC 61557 with those not covered by the respective parts of IEC 61557 is also within the scope of this document.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61557-16:2023 specifies the requirements applicable to the performance for test and measurement equipment in order to determine the effectiveness of the protective measures for electrical equipment and/or medical electrical equipment described in IEC 62353. This International Standard is to be used in conjunction with IEC 61557-1:2019. IEC 61557-16:2023 cancels and replaces the first edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) splitting of uncertainty requirements for medical and non-medical electrical equipment in 4.2.1; b) addition of a definition of ranges with defined uncertainty in 4.2.1 to 4.2.7; c) addition of an optional measuring device (MD) for non-medical devices in 4.2.1; d) addition of a limitation of the maximum intrinsic uncertainty for medical applications at leakage current in 4.2.1; e) change of 4.2.3 from test sockets to sockets for service purposes; f) addition of a warning in the operating instructions; g) integration of former 6.3 into 6.2; h) update of Table 1; i) alignment of the structure with that of the whole IEC 61557 series.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61557-13:2023 defines special performance requirements for hand-held and hand manipulated current clamps and sensors for measurement of leakage currents in electrical distribution systems up to 1 000 V AC and 1 500 V DC taking into account the influence of high external low-frequency magnetic fields and other influencing quantities. See Annex A for examples of measurement applications. This document does not apply to current clamps or sensors that are used in combination with devices for insulation fault location in accordance with IEC 61557-9, unless it is specified by the manufacturer. IEC 61557-13:2023 cancels and replaces the first edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) the term "fixing device" has been removed; b) the measuring range was changed to a display range, the indication of DC or peak values has been added in 4.1; c) the frequency for the test of sensitivity for low-frequency magnetic fields has been defined in 4.2; d) the specified measuring range is now defined as the range of indicated values based on the operating uncertainty in 4.3; e) alignment of the structure with that of the whole IEC 61557 series; f) the variation E12 (maximum load current), may be specified according to the manufacturer’s specification.
- Standard24 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61557-14:2023 defines special requirements for test and measurement equipment used to determine the electrical safety of electrical equipment of machinery in accordance with IEC 60204-1. This International Standard is to be used in conjunction with IEC 61557-1:2019. IEC 61557-14:2023 cancels and replaces the first edition published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) clarifying the introduction; b) replaced "dielectric strength" by "voltage test"; c) requirement for maximum output current has been added in 4.2.6.1; d) tripping time at electrical switching activated by two-hand operation has been added in 4.2.6.1; e) additional time limiting capability for the protection against electric shock for test persons and bystanders in 4.2.6.2; f) updated references for safety testing; g) alignment of the structure with that of the whole IEC 61557 series.
- Standard20 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61557-1:2019 specifies the general requirements applicable to measuring and monitoring equipment for testing the electrical safety in low-voltage distribution systems with nominal voltages up to 1 000 V AC and 1 500 V DC. When measuring equipment or measuring installations involve measurement tasks of various measuring equipment covered by this series of standards, then the part of this series relevant to each of the measurement tasks is applicable. Other parts of IEC 61557 can specify additional requirements or deviations. This document does not cover functional safety or cybersecurity. IEC 61557-1:2019 cancels and replaces the second edition published in 2007. This edition constitutes a technical revision. This third edition includes the following significant technical changes with respect to the previous edition:
a) terms aligned with IEC 60050;
b) measurement of uncertainty revised according to the equations in 4.2 of ISO/IEC Guide 98-3:2008 (GUM);
c) updated references for safety and EMC requirements;
d) updated references for marking and operating instructions;
e) updated references for testing safety and EMC;
f) Annex A contains an explanation of GUM;
g) Annex B addresses environmental aspects.
- Standard50 pagesEnglish languagesale 15% off
- Standard81 pagesEnglish languagesale 15% off
- Standard50 pagesEnglish and French languagesale 15% off
This part of IEC 61557 specifies the requirements for measuring equipment that combines several measuring functions or methods of testing, measuring or monitoring, that are in accordance with the respective parts of IEC 61557, into one piece of apparatus.
Measuring equipment which combines measuring functions or methods of testing, measuring or monitoring covered by the respective parts of IEC 61557 with those not covered by the respective parts of IEC 61557 is also within the scope of this document.
- Standard29 pagesEnglish languagesale 15% off
2022-06-02: CLC/TC 85X made a decision to temporarily remove the link, meanwhile working on the harmonziation issue via another amendment togther with CLC/TC 65X
- Amendment7 pagesEnglish languagesale 10% offe-Library read for1 day
- Corrigendum3 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61936-2:2023 provides, in a convenient form, requirements for the design and the erection of DC installations in systems with nominal voltages above 1,5 kV DC, so as to provide safety and proper functioning for the use intended.
For the purpose of interpreting this document, a DC installation is considered to be one of the following:
a) A converter station or DC switching station;
b) one (or more) DC generating or storage unit(s), such as solar farms or battery storage units, located on a single site, the DC installation includes DC equipment and cables with all associated power electronics, controlgear, switchgear and all electrical auxiliary systems. Connections between DC generating or storage units located on different sites are excluded;
c) DC installation erected on offshore facilities for the purpose of generation, transmission, distribution and/or storage of electricity; or
d) DC transition station (between overhead lines and underground cable or between different sections of underground cables).
This International Standard does not apply to the design and erection of any of the following:
- overhead and underground lines between separate installations;
- electric railways;
- mining equipment and installations;
i- installations on ships according to IEC 60092 series and offshore units according to IEC 61892 series, which are used in the offshore petroleum industry for drilling, processing and storage purposes;
- electrostatic equipment (e.g. electrostatic precipitators, spray-painting units);
- test sites;
- medical equipment, e.g. medical X-ray equipment;
- valve hall or converter hall.
This document does not apply to the requirements for carrying out live working on electrical installations.
This document does not apply to the design of factory-built, type-tested thyristor valves, VSC valves and switchgear for which separate IEC standards exist.
This first edition cancels and replaces the IEC TS 61936-2 published in 2015. This edition constitutes a technical revision.
See the foreword of this edition for the list of significant technical changes with respect to the previous edition.
- Standard52 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61936-2:2023 provides, in a convenient form, requirements for the design and the erection of DC installations in systems with nominal voltages above 1,5 kV DC, so as to provide safety and proper functioning for the use intended. For the purpose of interpreting this document, a DC installation is considered to be one of the following: a) A converter station or DC switching station; b) one (or more) DC generating or storage unit(s), such as solar farms or battery storage units, located on a single site, the DC installation includes DC equipment and cables with all associated power electronics, controlgear, switchgear and all electrical auxiliary systems. Connections between DC generating or storage units located on different sites are excluded; c) DC installation erected on offshore facilities for the purpose of generation, transmission, distribution and/or storage of electricity; or d) DC transition station (between overhead lines and underground cable or between different sections of underground cables). This International Standard does not apply to the design and erection of any of the following: - overhead and underground lines between separate installations; - electric railways; - mining equipment and installations; i- installations on ships according to IEC 60092 series and offshore units according to IEC 61892 series, which are used in the offshore petroleum industry for drilling, processing and storage purposes; - electrostatic equipment (e.g. electrostatic precipitators, spray-painting units); - test sites; - medical equipment, e.g. medical X-ray equipment; - valve hall or converter hall. This document does not apply to the requirements for carrying out live working on electrical installations. This document does not apply to the design of factory-built, type-tested thyristor valves, VSC valves and switchgear for which separate IEC standards exist. This first edition cancels and replaces the IEC TS 61936-2 published in 2015. This edition constitutes a technical revision. See the foreword of this edition for the list of significant technical changes with respect to the previous edition.
- Standard52 pagesEnglish languagesale 10% offe-Library read for1 day
2022-06-02: CLC/TC 85X made a decision to temporarily remove the link, meanwhile working on the harmonziation issue via another amendment togther with CLC/TC 65X
- Amendment7 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61936-2:2023 provides, in a convenient form, requirements for the design and the erection of DC installations in systems with nominal voltages above 1,5 kV DC, so as to provide safety and proper functioning for the use intended.
For the purpose of interpreting this document, a DC installation is considered to be one of the following:
a) A converter station or DC switching station;
b) one (or more) DC generating or storage unit(s), such as solar farms or battery storage units, located on a single site, the DC installation includes DC equipment and cables with all associated power electronics, controlgear, switchgear and all electrical auxiliary systems. Connections between DC generating or storage units located on different sites are excluded;
c) DC installation erected on offshore facilities for the purpose of generation, transmission, distribution and/or storage of electricity; or
d) DC transition station (between overhead lines and underground cable or between different sections of underground cables).
This International Standard does not apply to the design and erection of any of the following:
- overhead and underground lines between separate installations;
- electric railways;
- mining equipment and installations;
i- installations on ships according to IEC 60092 series and offshore units according to IEC 61892 series, which are used in the offshore petroleum industry for drilling, processing and storage purposes;
- electrostatic equipment (e.g. electrostatic precipitators, spray-painting units);
- test sites;
- medical equipment, e.g. medical X-ray equipment;
- valve hall or converter hall.
This document does not apply to the requirements for carrying out live working on electrical installations.
This document does not apply to the design of factory-built, type-tested thyristor valves, VSC valves and switchgear for which separate IEC standards exist.
This first edition cancels and replaces the IEC TS 61936-2 published in 2015. This edition constitutes a technical revision.
See the foreword of this edition for the list of significant technical changes with respect to the previous edition.
- Standard102 pagesEnglish and French languagesale 15% off
IEC 61557-13:2023 defines special performance requirements for hand-held and hand manipulated current clamps and sensors for measurement of leakage currents in electrical distribution systems up to 1 000 V AC and 1 500 V DC taking into account the influence of high external low-frequency magnetic fields and other influencing quantities. See Annex A for examples of measurement applications.
This document does not apply to current clamps or sensors that are used in combination with devices for insulation fault location in accordance with IEC 61557-9, unless it is specified by the manufacturer.
IEC 61557-13:2023 cancels and replaces the first edition published in 2011. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) the term "fixing device" has been removed;
b) the measuring range was changed to a display range, the indication of DC or peak values has been added in 4.1;
c) the frequency for the test of sensitivity for low-frequency magnetic fields has been defined in 4.2;
d) the specified measuring range is now defined as the range of indicated values based on the operating uncertainty in 4.3;
e) alignment of the structure with that of the whole IEC 61557 series;
f) the variation E12 (maximum load current), may be specified according to the manufacturer’s specification.
- Standard41 pagesEnglish and French languagesale 15% off
IEC 61557-16:2023 specifies the requirements applicable to the performance for test and measurement equipment in order to determine the effectiveness of the protective measures for electrical equipment and/or medical electrical equipment described in IEC 62353.
This International Standard is to be used in conjunction with IEC 61557-1:2019.
IEC 61557-16:2023 cancels and replaces the first edition published in 2014. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) splitting of uncertainty requirements for medical and non-medical electrical equipment in 4.2.1;
b) addition of a definition of ranges with defined uncertainty in 4.2.1 to 4.2.7;
c) addition of an optional measuring device (MD) for non-medical devices in 4.2.1;
d) addition of a limitation of the maximum intrinsic uncertainty for medical applications at leakage current in 4.2.1;
e) change of 4.2.3 from test sockets to sockets for service purposes;
f) addition of a warning in the operating instructions;
g) integration of former 6.3 into 6.2;
h) update of Table 1;
i) alignment of the structure with that of the whole IEC 61557 series.
- Standard42 pagesEnglish and French languagesale 15% off
IEC 61557-14:2023 defines special requirements for test and measurement equipment used to determine the electrical safety of electrical equipment of machinery in accordance with IEC 60204-1.
This International Standard is to be used in conjunction with IEC 61557-1:2019.
IEC 61557-14:2023 cancels and replaces the first edition published in 2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) clarifying the introduction;
b) replaced "dielectric strength" by "voltage test";
c) requirement for maximum output current has been added in 4.2.6.1;
d) tripping time at electrical switching activated by two-hand operation has been added in 4.2.6.1;
e) additional time limiting capability for the protection against electric shock for test persons and bystanders in 4.2.6.2;
f) updated references for safety testing;
g) alignment of the structure with that of the whole IEC 61557 series.
- Standard33 pagesEnglish and French languagesale 15% off
This part of IEC 60071 constitutes application guidelines and deals with the selection of insulation levels of equipment or installations for three-phase a.c. systems. Its aim is to give guidance for the determination of the rated withstand voltages for ranges I and II of IEC 60071- 1 and to justify the association of these rated values with the standardized highest voltages for equipment.
This association is for insulation co-ordination purposes only. The requirements for human safety are not covered by this document.
This document covers three-phase a.c. systems with nominal voltages above 1 kV. The values derived or proposed herein are generally applicable only to such systems. However, the concepts presented are also valid for two-phase or single-phase systems.
This document covers phase-to-earth, phase-to-phase and longitudinal insulation.
This document is not intended to deal with routine tests. These are to be specified by the relevant product committees.
The content of this document strictly follows the flow chart of the insulation co-ordination process presented in Figure 1 of IEC 60071-1:2019. Clauses 5 to 8 correspond to the squares in this flow chart and give detailed information on the concepts governing the insulation coordination process which leads to the establishment of the required withstand levels.
This document emphasizes the necessity of considering, at the very beginning, all origins, all classes and all types of voltage stresses in service irrespective of the range of highest voltage for equipment. Only at the end of the process, when the selection of the standard withstand voltages takes place, does the principle of covering a particular service voltage stress by a standard withstand voltage apply. Also, at this final step, this document refers to the correlation made in IEC 60071-1 between the standard insulation levels and the highest voltage for equipment.
The annexes contain examples and detailed information which explain or support the concepts described in the main text, and the basic analytical techniques used.
- Standard187 pagesEnglish languagesale 10% offe-Library read for1 day
IEC TS 61936-0:2023 provides principles to ensure the coherence amongst HV publications to be observed necessary for the coordination of the design, selection of equipment, operation, and maintenance activities for erection of electrical HV installations to ensure the safety of such systems.
In the context of this document, "safety" relates to the safety of persons, domestic animals, livestock and property.
This Technical Specification is intended for use by technical committees in the preparation of standards with safety aspects which can be a part of an electrical high voltage installation
- Technical specification29 pagesEnglish languagesale 15% off
IEC 60071-11:2022 applies to high-voltage direct current (HVDC) systems. It specifies the principles on the procedures for the determination of the specified withstand voltages, creepage distance and air clearances for the equipment and the installations of these systems.
This document gives the insulation co-ordination principles related to line commutated converter (LCC) and voltage sourced converters (VSC) HVDC systems. The main principles of this document also apply to other special converter configurations of LCC, such as the capacitor commutated converter (CCC) as well as the controlled series compensated converter (CSCC), etc.
This document applies to insulation co-ordination of equipment connected between the converter AC bus (including the AC harmonic filters, the converter transformer, the circuit breakers) and the DC line side. The line and cable terminations in so far as they influence the insulation co-ordination of converter station equipment are also covered.
This document applies only for HVDC applications in power systems and not for industrial conversion equipment. Principles and guidance given are for insulation co-ordination purposes only. The requirements for human safety are not covered by this document.
This international standard replaces, in conjunction with IEC 60071-12, IEC 60071-5 published in 2014.
This edition includes the following significant technical changes with respect to IEC 60071‑5:2014:
- This standard applies to both LCC and VSC HVDC systems whereas IEC 60071-5 only dealt with LCC HVDC system;
- Annex C (normative) gives the recommended specified withstand voltage (LI and SI);
- Annex C (normative) gives the minimum air clearances;
- Annex E shows the correlation of clauses between this standard and IEC 60071-5:2014.
- Standard41 pagesEnglish languagesale 10% offe-Library read for1 day
IEC Corrected Version
- Corrigendum4 pagesFrench languagesale 10% offe-Library read for1 day
IEC Corrected Version
- Corrigendum4 pagesFrench languagesale 10% offe-Library read for1 day
IEC Corrected Version
- Corrigendum4 pagesFrench languagesale 10% offe-Library read for1 day
IEC Corrected Version
- Corrigendum4 pagesFrench languagesale 10% offe-Library read for1 day
- Standard2 pagesEnglish and French languagesale 15% off
- Standard2 pagesEnglish and French languagesale 15% off
IEC 61557-3:2019 is available as IEC 61557-3:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61557-3:2019 specifies the requirements applicable to equipment for measuring the loop impedance between a line conductor and protective conductor; between a line conductor and neutral; or between two line conductors by using the voltage drop when the circuit under test is loaded. IEC 61557-3:2019 cancels and replaces the second edition published in 2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) addition of equirements as regards the measurement category;
b) addition of new requirements for operating instructions;
c) alignment of the structure with that of the whole IEC 61557 series.
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61557-11:2009 specifies the requirements for testing equipment applied to the testing of the effectiveness of residual current monitors (RCMs) of type A and type B, which are already installed in distribution systems. This test equipment can be used in any kind of network like a TN, TT or IT system. The test equipment may also be used for testing directionally discriminating RCMs in IT-Systems.This part is to be used in conjunction with IEC 61557-1:2007, Part 1: General requirements.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61557-3:2019 is available as IEC 61557-3:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61557-3:2019 specifies the requirements applicable to equipment for measuring the loop impedance between a line conductor and protective conductor; between a line conductor and neutral; or between two line conductors by using the voltage drop when the circuit under test is loaded. IEC 61557-3:2019 cancels and replaces the second edition published in 2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) addition of equirements as regards the measurement category; b) addition of new requirements for operating instructions; c) alignment of the structure with that of the whole IEC 61557 series.
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61557-7:2019 is available as IEC 61557-7:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61557-7:2019 specifies the requirements applicable to measuring equipment for testing the phase sequence in three-phase distribution systems. Indication of the phase sequence can be mechanical, visual and/or audible. This document does not apply to additional measurements for other quantities. It does not apply to monitoring relays. IEC 61557-7:2019 cancels and replaces the second edition published in 2007. This edition constitutes a technical revision. This edition includes the following changes with respect to the previous edition: a) alignment of the structure with that of the whole IEC 61557 series; b) updated requirements in 4.3 in accordance with new editions of IEC 61010-1 and IEC 61010-031; c) the information on markings was extended; d) the information on the operating instructions was extended; e) complement to the information on the testing of leads; f) test leads for insulated conductors were introduced; g) Annex B was added with information on phase sequence tests and indications.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61557-11:2009 specifies the requirements for testing equipment applied to the testing of the effectiveness of residual current monitors (RCMs) of type A and type B, which are already installed in distribution systems. This test equipment can be used in any kind of network like a TN, TT or IT system. The test equipment may also be used for testing directionally discriminating RCMs in IT-Systems.This part is to be used in conjunction with IEC 61557-1:2007, Part 1: General requirements.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61557-6:2019 is available as IEC 61557-6:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61557-6:2019 specifies the requirements applicable to measuring equipment for testing the effectiveness of protective measures of residual current devices (RCD) installed in TT, TN and IT systems. It is not the purpose of this document to verify the RCD according to their product standards. IEC 61557-6:2019 cancels and replaces the second edition published in 2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) addition of requirements for testing a new type of RCD;
b) addition of requirements for type B RCDs (former Annex B);
c) addition of new Annex B on recommended tripping times;
d) alignment of the structure with that of the whole IEC 61557 series.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61557-1:2019 is available as IEC 61557-1:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61557-1:2019 specifies the general requirements applicable to measuring and monitoring equipment for testing the electrical safety in low-voltage distribution systems with nominal voltages up to 1 000 V AC and 1 500 V DC. When measuring equipment or measuring installations involve measurement tasks of various measuring equipment covered by this series of standards, then the part of this series relevant to each of the measurement tasks is applicable. Other parts of IEC 61557 can specify additional requirements or deviations. This document does not cover functional safety or cybersecurity. IEC 61557-1:2019 cancels and replaces the second edition published in 2007. This edition constitutes a technical revision. This third edition includes the following significant technical changes with respect to the previous edition:
a) terms aligned with IEC 60050;
b) measurement of uncertainty revised according to the equations in 4.2 of ISO/IEC Guide 98-3:2008 (GUM);
c) updated references for safety and EMC requirements;
d) updated references for marking and operating instructions;
e) updated references for testing safety and EMC;
f) Annex A contains an explanation of GUM;
g) Annex B addresses environmental aspects.
- Standard29 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61557-12:2018 is available as IEC 61557-12:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61557-12:2018 specifies requirements for power metering and monitoring devices (PMD) that measure and monitor the electrical quantities within electrical distribution systems, and optionally other external signals. These requirements also define the performance in single- and three-phase AC or DC systems having rated voltages up to 1 000 V AC or up to 1 500 V DC. These devices are fixed or portable. They are intended to be used indoors and/or outdoors. Power metering and monitoring devices (PMD), as defined in this document, give additional safety information, which aids the verification of the installation and enhances the performance of the distribution systems. The power metering and monitoring devices (PMD) for electrical parameters described in this document are used for general industrial and commercial applications. This document does not address functional safety and cyber security aspects. This document is not applicable for:
– electricity metering equipment that complies with IEC 62053-21, IEC 62053-22, IEC 62053-23 and IEC 62053-24. Nevertheless, uncertainties defined in this document for active and reactive energy measurement are derived from those defined in IEC 62053 (all parts);
– the measurement and monitoring of electrical parameters defined in IEC 61557-2 to IEC 61557-9 and IEC 61557-13 or in IEC 62020;
– power quality instrument (PQI) according IEC 62586 (all parts);
– devices covered by IEC 60051 (all parts) (direct acting analogue electrical measuring instrument). IEC 61557-12:2018 cancels and replaces the first edition published in 2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) PMD-A has been withdrawn due the fact these devices are now mainly covered by the IEC 62586 series of standards.
b) Three categories of PMD have been created with a list of minimum required functions for each category.
c) Added a new Annex A explaining the different applications linked to the relevant standards and devices, and another new Annex C about the power factor conventions.
- Standard106 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 61557 defines minimum performance requirements for non-contact AC voltage indicators to reduce the risk of electric shock for the testing person and bystanders caused by the wrong interpretation of the indication.
Products designed and manufactured in accordance with this document are for use by (electrically) skilled persons only. Non-contact AC voltage indicators are not designed for testing the absence of the operating voltage.
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 61557 specifies requirements for power metering and monitoring devices (PMD) that measure and monitor the electrical quantities within electrical distribution systems, and optionally other external signals. These requirements also defin the performance of PMD in single- and three-phace AC or DC systems having rated voltages up to 1000 V AC or up to 1500 V DC.
These devices are fixed or portable. They are intended to be used indoors and/or outdoors.
Power metering and monitoring devices (PMD), as defined in this document, give additional safety information, which aids the verification of the installation and enhances the performance of the distribution systems.
Additionally, this document specifies requirements for measurement functions dedicated to metering and monitoring of electrical parameters called power metering and monitoring function (PMF) which can be embedded in equipment (EMPF) that is not classified as PMD and for which the main function is not power metering and monitoring.
Requirements for power metering and monitoring function (PMF) and additional requirements for equipments embedding power metering and monitoring function (EPMF) are described in Annex H.
The power metering and monitoring devices (PMD) for electrical parameters described in this document are used for general industrial and commercial applications.
This document does not address functional safety and cyber security aspects.
This document is not applicable to:
- electricity metering equipment that complies with IEC 62053-21, IEC 62053-22, IEC 62053-23 and IEC 62053-24. Nevertheless, uncertainties defined in this document for active and reactive energy measurement are derived from those defined in IEC 62053 (all parts);
- the measurement and monitoring of electrical parameters defined in IEC 61557-2 to IEC 61557-9 and IEC 61557-13 or in IEC 62020;
- power quality instrument (PQI) according IEC 62586 (all parts);
- devices covered by IEC 60051 (all parts) (direct acting analogue electrical measuring instrument).
Note 1 Generally such types of devices are used in the following applications or for the following general needs:
- energy management inside the installation, such as facilitating the implementation of documents such as ISO 50001 and IEC 60364-8-1;
- monitoring and/or measurement of electrical parameters;
- measurement and/or monitoring of the quality of energy inside commercial/industrial installations.
Note 2 A measuring and monitoring device of electrical parameters usually consists of several functional modules. All or some of the functional modules are combined in one device. Examples of fuctnional modules are:
- measurement and monitoring of several electrical parameters simultaneously;
- energy measurement and/or monitoring, as well as sometimes compliance with aspects of building regulations;
- alarms functions;
- demand side quality (current and voltage harmonics, over/under voltages, voltage dips and swells, etc.).
Note 3 PMD are historically called power meter, power monitor, power monitor device, power energy monitoring device, power analyser, multifunction meter, measuring multifunction equipment, energe meters.
Note 4 Metering, measuring and monitoring applications are explained in Annex A.
- Amendment26 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61557-5:2019 is available as IEC 61557-5:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61557-5:2019 specifies the requirements applicable to measuring equipment for measuring the resistance to earth using an AC voltage. IEC 61557-5:2019 cancels and replaces the second edition published in 2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) definitions and symbols in Clause 3 modified;
b) subclauses in Clause 4 restructured and aligned with other parts of the series;
c) limits for reduced voltages 25 V RMS or 35 V peak removed from 4.5;
d) requirements for clamps added;
e) marking for rated voltages to earth and measurement category added to Clause 5;
f) warning about absence of hazardous voltage added in Clause 5;
g) the term "percentage operating uncertainty" replaced by "operating uncertainty" in Clause 6;
h) equation for uncertainty corrected in Table 1;
i) new Annex A on test measurements with loop clamps added.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61557-2:2019 is available as IEC 61557-2:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61557-2:2019 specifies the requirements applicable to equipment for measuring the insulation resistance of equipment and installations in the de-energized state IEC 61557-2:2019 cancels and replaces the second edition published in 2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) addition of requirements as regards measurement category;
b) addition of new requirements for operating instructions;
c) alignment of the structure with that of the the whole IEC 61557 series.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61557-4:2019 is available as IEC 61557-4:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61557-4:2019 specifies the requirements applicable to equipment for measuring the resistance of earth conductors, protective earth conductors and conductors for equipotential bonding, including their connections and terminals, with an indication of the measured value or an indication of the limits. IEC 61557-4:2019 cancels and replaces the second edition published in 2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) complement to the measurement category in Clause 4;
b) correction of the equation for operating uncertainty;
c) complement to the requirements for measuring with DC;
d) alignment of the structure with that of the whole IEC 61557 series.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61557-12:2018 is available as IEC 61557-12:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61557-12:2018 specifies requirements for power metering and monitoring devices (PMD) that measure and monitor the electrical quantities within electrical distribution systems, and optionally other external signals. These requirements also define the performance in single- and three-phase AC or DC systems having rated voltages up to 1 000 V AC or up to 1 500 V DC. These devices are fixed or portable. They are intended to be used indoors and/or outdoors. Power metering and monitoring devices (PMD), as defined in this document, give additional safety information, which aids the verification of the installation and enhances the performance of the distribution systems. The power metering and monitoring devices (PMD) for electrical parameters described in this document are used for general industrial and commercial applications. This document does not address functional safety and cyber security aspects. This document is not applicable for: – electricity metering equipment that complies with IEC 62053-21, IEC 62053-22, IEC 62053-23 and IEC 62053-24. Nevertheless, uncertainties defined in this document for active and reactive energy measurement are derived from those defined in IEC 62053 (all parts); – the measurement and monitoring of electrical parameters defined in IEC 61557-2 to IEC 61557-9 and IEC 61557-13 or in IEC 62020; – power quality instrument (PQI) according IEC 62586 (all parts); – devices covered by IEC 60051 (all parts) (direct acting analogue electrical measuring instrument). IEC 61557-12:2018 cancels and replaces the first edition published in 2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) PMD-A has been withdrawn due the fact these devices are now mainly covered by the IEC 62586 series of standards. b) Three categories of PMD have been created with a list of minimum required functions for each category. c) Added a new Annex A explaining the different applications linked to the relevant standards and devices, and another new Annex C about the power factor conventions.
- Standard106 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 61557 specifies requirements for power metering and monitoring devices (PMD) that measure and monitor the electrical quantities within electrical distribution systems, and optionally other external signals. These requirements also defin the performance of PMD in single- and three-phace AC or DC systems having rated voltages up to 1000 V AC or up to 1500 V DC. These devices are fixed or portable. They are intended to be used indoors and/or outdoors. Power metering and monitoring devices (PMD), as defined in this document, give additional safety information, which aids the verification of the installation and enhances the performance of the distribution systems. Additionally, this document specifies requirements for measurement functions dedicated to metering and monitoring of electrical parameters called power metering and monitoring function (PMF) which can be embedded in equipment (EMPF) that is not classified as PMD and for which the main function is not power metering and monitoring. Requirements for power metering and monitoring function (PMF) and additional requirements for equipments embedding power metering and monitoring function (EPMF) are described in Annex H. The power metering and monitoring devices (PMD) for electrical parameters described in this document are used for general industrial and commercial applications. This document does not address functional safety and cyber security aspects. This document is not applicable to: - electricity metering equipment that complies with IEC 62053-21, IEC 62053-22, IEC 62053-23 and IEC 62053-24. Nevertheless, uncertainties defined in this document for active and reactive energy measurement are derived from those defined in IEC 62053 (all parts); - the measurement and monitoring of electrical parameters defined in IEC 61557-2 to IEC 61557-9 and IEC 61557-13 or in IEC 62020; - power quality instrument (PQI) according IEC 62586 (all parts); - devices covered by IEC 60051 (all parts) (direct acting analogue electrical measuring instrument). Note 1 Generally such types of devices are used in the following applications or for the following general needs: - energy management inside the installation, such as facilitating the implementation of documents such as ISO 50001 and IEC 60364-8-1; - monitoring and/or measurement of electrical parameters; - measurement and/or monitoring of the quality of energy inside commercial/industrial installations. Note 2 A measuring and monitoring device of electrical parameters usually consists of several functional modules. All or some of the functional modules are combined in one device. Examples of fuctnional modules are: - measurement and monitoring of several electrical parameters simultaneously; - energy measurement and/or monitoring, as well as sometimes compliance with aspects of building regulations; - alarms functions; - demand side quality (current and voltage harmonics, over/under voltages, voltage dips and swells, etc.). Note 3 PMD are historically called power meter, power monitor, power monitor device, power energy monitoring device, power analyser, multifunction meter, measuring multifunction equipment, energe meters. Note 4 Metering, measuring and monitoring applications are explained in Annex A.
- Amendment26 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 61557 defines minimum performance requirements for non-contact AC voltage indicators to reduce the risk of electric shock for the testing person and bystanders caused by the wrong interpretation of the indication. Products designed and manufactured in accordance with this document are for use by (electrically) skilled persons only. Non-contact AC voltage indicators are not designed for testing the absence of the operating voltage.