IEC 62196-2:2025 applies to EV plugs, EV socket-outlets, vehicle connectors and vehicle inlets with pins and contact-tubes of standardized configurations, herein referred to as "accessories". These accessories have a nominal rated operating voltage not exceeding 480 V AC, 50 Hz to 60 Hz, and a rated current not exceeding 63 A three phase or 70 A single phase, for use in conductive charging of electric vehicles.
This fourth edition cancels and replaces the third edition published in 2022. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) addition of new tests for latching devices;
b) corrections to standard sheets.
- Standard84 pagesEnglish languagesale 15% off
- Standard84 pagesFrench languagesale 15% off
- Standard168 pagesEnglish and French languagesale 15% off
IEC 62196-1:2025 is applicable to EV plugs, EV socket-outlets, vehicle connectors, vehicle inlets, herein referred to as "accessories", and to cable assemblies for electric vehicles (EV) intended for use in conductive charging systems which incorporate control means, with a rated operating voltage not exceeding
- 690 V AC 50 Hz to 60 Hz, at a rated current not exceeding 250 A, and
- 1 500 V DC at a rated current not exceeding 800 A.
This fifth edition cancels and replaces the fourth edition published in 2022. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) addition of new tests for latching devices and retaining means;
b) inclusion of type 4 accessories.
- Standard110 pagesEnglish languagesale 15% off
- Standard115 pagesFrench languagesale 15% off
- Standard225 pagesEnglish and French languagesale 15% off
IEC 60884-2-8:2025 applies to socket-outlets for furniture for AC only, with or without earthing contact, with or without supply cable, with a rated voltage greater than 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors.
This document covers socket-outlets for furniture which are intended to be built into or fixed into furniture and are not intended to be moved from one place to another without removing the fixing means.
- Standard32 pagesEnglish languagesale 15% off
IEC 60884-3-1:2021 applies to fixed or portable socket-outlets for AC only, with or without earthing contact, with a rated voltage greater than 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors, incorporating USB power supply.
This document defines the safety and EMC requirements for socket-outlets incorporating USB power supply.
Specifications, performance and dimensional requirements of the USB technologies are not covered by this document; they are defined in the relevant part(s) of IEC 62680.
The contents of the corrigendum of July 2024 have been included in this copy.
- Standard1 pageEnglish and French languagesale 15% off
IEC 60884-2-3:2025 applies to switched socket-outlets without interlock, for fixed installation, for AC only, with or without earthing contact, with a rated voltage not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors. This document applies to socket-outlets controlled by a manually operated mechanical switch.
This third edition cancels and replaces the second edition published in 2006. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment to IEC 60884-1, fourth edition.
- Standard35 pagesEnglish languagesale 15% off
IEC 60884-2-2:2025 applies to socket-outlets for AC only, with or without earthing contact, with a rated voltage not exceeding 250 V and a rated current not exceeding 16 A, which are integrated or intended to be incorporated in or fixed to appliances, hereafter referred to as socket-outlets for appliances. This third edition cancels and replaces the second edition published in 2006. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment to IEC 60884‑1 fourth edition.
- Standard28 pagesEnglish languagesale 15% off
IEC 60884-2-6:2025 applies to switched socket-outlets with interlock for AC only, for fixed electrical installations, with or without earthing contact, with rated voltage above 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors. Switched socket-outlets with interlock according to this document consist of a combination of socket-outlets according to IEC 60884‑1, interlocked with a switch according to IEC 60669‑1 and/or IEC 60669‑2‑1 supplied as a complete accessory. The rated current is limited to 16 A maximum for fixed accessories provided with screwless terminals.
This document does not cover requirements for flush mounting boxes. However, it covers those requirements for surface-type mounting boxes which are necessary for the tests on socket-outlets.
This second edition cancels and replaces the first edition published in 1997. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment to IEC 60884-1, fourth edition.
- Standard34 pagesEnglish languagesale 15% off
IEC 60884-2-7:2025 applies to cord extension sets, rewirable and non-rewirable, with or without earthing contact, with a rated voltage greater than 50 V but not exceeding 440 V and a rated current not exceeding 16 A, intended for household and similar purposes, either indoors or outdoors. This document does not apply to cord extension sets with means for reeling. Cord extension sets intended to be used as socket-outlets for furniture are additionally covered by IEC 60884‑2‑8. This document also applies to cord extension sets which are intended to be used in a cable reel, and which therefore become cable reels with a detachable flexible cable. For the combination of the cord extension set, the reel requirements and tests of IEC 61242 apply in addition.
Cord extension sets are suitable for use at ambient temperatures not normally exceeding +40 °C, but their average temperature over a period of 24 h does not exceed +35 °C, with a lower limit of the ambient air temperature of −5 °C.
This second edition cancels and replaces the first edition published in 2011, and Amendment 1:2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment to IEC 60884-1, fourth edition.
- Standard40 pagesEnglish languagesale 15% off
IEC 60884-2-1:2025 applies to fused plugs, where the fuses are primarily intended to protect the flexible cable connected to the plug. These fuses are not intended to protect appliances or parts of them against overload.
This third edition cancels and replaces the second edition published in 2006. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment to IEC 60884‑1, fourth edition.
- Standard21 pagesEnglish languagesale 15% off
The shore supply system is used while the rolling stock is standing still within depots and sidings location for providing power to the AC auxiliary loads (which can include battery charging) when the primary power supply (contact line) is not available or used.
This document:
- specifies requirements to the shore supply and to the rolling stock for safe operation on shore supply operation;
- specifies the requirements to ensure compatibility of class C0 and C1 train types as given in CLC/TS 50534:2010 systems and three-phase shore power supply systems;
- provides a complete system design for 63/125 A shore supplies including the interfaces (power and control loop) between shore supply and rolling stock;
- specifies the requirements with regards to interoperability with AC and DC fed traction systems in order to prevent undesired stray currents and adverse interaction with signalling systems when operating on shore supply;
- defines the electrical characteristics of the 63/125 A shore power supply;
- defines the 63/125 A connectors and its intermateability to provide interoperability for rolling stock that is to run across borders;
- defines the 600 A connector and its intermateability;
- can be used for other type of rail vehicles and purposes, if agreed by the manufacturer and customer
- does not apply to shore supplies to move the rolling stock;
- does not describe the 600 A shore supply system.
NOTE 1 The 600 A connector is the existing UK standard three-phase shore supply connector which has a long service history.
NOTE 2 The connectors are dimensioned using standard rolling stock cables as set out in EN 50264-3-1:2008.
NOTE 3 Examples of other usage and rail vehicles are: e.g. light rail vehicles, class A train types, traction battery charging etcetera.
- Standard85 pagesEnglish languagesale 10% offe-Library read for1 day
The shore supply system is used while the rolling stock is standing still within depots and sidings location for providing power to the AC auxiliary loads (which can include battery charging) when the primary power supply (contact line) is not available or used. This document: - specifies requirements to the shore supply and to the rolling stock for safe operation on shore supply operation; - specifies the requirements to ensure compatibility of class C0 and C1 train types as given in CLC/TS 50534:2010 systems and three-phase shore power supply systems; - provides a complete system design for 63/125 A shore supplies including the interfaces (power and control loop) between shore supply and rolling stock; - specifies the requirements with regards to interoperability with AC and DC fed traction systems in order to prevent undesired stray currents and adverse interaction with signalling systems when operating on shore supply; - defines the electrical characteristics of the 63/125 A shore power supply; - defines the 63/125 A connectors and its intermateability to provide interoperability for rolling stock that is to run across borders; - defines the 600 A connector and its intermateability; - can be used for other type of rail vehicles and purposes, if agreed by the manufacturer and customer - does not apply to shore supplies to move the rolling stock; - does not describe the 600 A shore supply system. NOTE 1 The 600 A connector is the existing UK standard three-phase shore supply connector which has a long service history. NOTE 2 The connectors are dimensioned using standard rolling stock cables as set out in EN 50264-3-1:2008. NOTE 3 Examples of other usage and rail vehicles are: e.g. light rail vehicles, class A train types, traction battery charging etcetera.
- Standard85 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60884-3-1:2021 applies to fixed or portable socket-outlets for AC only, with or without earthing contact, with a rated voltage greater than 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors, incorporating USB power supply.
This document defines the safety and EMC requirements for socket-outlets incorporating USB power supply.
Specifications, performance and dimensional requirements of the USB technologies are not covered by this document; they are defined in the relevant part(s) of IEC 62680.
- Standard6 pagesEnglish and French languagesale 15% off
- Amendment9 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60884-1:2022 applies to plugs and fixed or portable socket-outlets for AC only, with or without earthing contact, with a rated voltage greater than 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors.
Compatible plugs and socket-outlets, when combined, form a plug and socket-outlet system. Standardized systems used around the world are reported in IEC/TR 60083.
The rated current is limited to 16 A maximum for accessories provided with screwless-type terminals.
This fourth edition cancels and replaces the third edition published in 2002, Amendment 1:2006 and Amendment 2:2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
plugs and socket-outlets incorporating pilot lights;
crimped connections in accessories;
insulation piercing terminals (IPT);
accessories to be used with American Wire Gauge (AWG) cables;
accessories used in T° below −5 °C down to and including −45 °C;
accessories used in T° above +40 °C up to and including +70 °C;
plugs and socket-outlets for high load (HL);
clarification of some definitions;
durability of markings test;
introduction of thermal monitoring in the plug;
requirements for shutters in portable socket-outlets;
test walls for the verification of ingress of water;
rewriting of the temperature rise clause.
- Standard7 pagesEnglish and French languagesale 15% off
- Amendment9 pagesEnglish languagesale 10% offe-Library read for1 day
- Corrigendum3 pagesEnglish and French languagesale 10% offe-Library read for1 day
- Corrigendum3 pagesEnglish and French languagesale 10% offe-Library read for1 day
- Standard1 pageEnglish and French languagesale 15% off
IEC PAS 63472:2023 describes dimensional options for CONFIGURATION FF AC/DC contact-tube vehicle couplers as defined in IEC 62196-3. These possibilities serve to improve the reliability of a mated connection when the charging cable is not axially constrained. The options can be implemented optionally and maintain mating compatibility with CONFIGURATION FF according to IEC 62196-3.
- Technical specification12 pagesEnglish languagesale 15% off
This part of IEC 62196 applies to EV plugs, EV socket-outlets, vehicle connectors and vehicle inlets with pins and contact-tubes of standardized configurations, herein referred to as accessories. These accessories have a nominal rated operating voltage not exceeding 480 V AC, 50 Hz to 60 Hz, and a rated current not exceeding 63 A three phase or 70 A single phase, for use in conductive charging of electric vehicles.
This document covers the basic interface accessories for vehicle supply as specified in IEC 62196-1.
NOTE 1 The term "Electric road vehicles (EV)" comprises all road vehicles, including plug-in hybrid road vehicles (PHEV) that derive all or part of their energy from the rechargeable energy storage systems (RESS).
These accessories are intended to be used for circuits specified in IEC 61851-1:2017, which operate at different voltages and frequencies, and which can include extra-low voltage (ELV) and communication signals.
The use of these accessories for bidirectional power transfer is under consideration.
This document applies to accessories to be used in an ambient temperature between -30 °C and +40 °C.
NOTE 2 In the following country, other requirements regarding the lower temperature may apply: NO.
NOTE 3 In the following country, −35 °C applies: SE.
These accessories are intended to be connected only to cables with copper or copper-alloy conductors.
Vehicle inlets and vehicle connectors described in this document are intended to be used for charging in modes 1, 2 and 3, cases B and C. The EV socket-outlets and EV plugs covered by this document are intended to be used for charging mode 3 only, case A and B.
The modes and permissible connections are specified in IEC 61851-1:2017.
- Standard69 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 62196 is applicable to vehicle couplers with pins and contact tubes of standardized configuration, herein also referred to as "accessories", intended for use in electric vehicle conductive charging systems which incorporate control means, with rated operating voltage and current in accordance with IEC 62196-1:2022.
This document applies to high power DC interfaces and combined AC/DC interfaces of vehicle couplers that are intended for use in conductive charging systems for circuits specified in IEC 61851-1:2017 and IEC 6185123:-2.
The DC vehicle connectors and inlets covered by this document are used only in charging mode 4, according to IEC 618511:2017, 6.2.4, and case C, as shown in IEC 618511:2017, Figure 3.
These vehicle couplers are intended to be used for circuits specified in IEC 61851-23: - which operate at different voltages, and which can include ELV and communication signals.
This document applies to the vehicle couplers to be used in an ambient temperature between -30 °C and +40 °C.
NOTE 1 In some countries, other requirements may apply.
NOTE 2 In the following country, −35 °C applies: SE.
These vehicle couplers are intended to be connected only to cables with copper or copper-alloy conductors.
- Standard69 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 62196 is applicable to EV plugs, EV socket-outlets, vehicle connectors, vehicle inlets, herein referred to as "accessories", and to cable assemblies for electric vehicles (EV) intended for use in conductive charging systems which incorporate control means, with a rated operating voltage not exceeding:
- 690 V AC 50 Hz to 60 Hz, at a rated current not exceeding 250 A;
- 1 500 V DC at a rated current not exceeding 800 A.
These accessories and cable assemblies are intended to be installed by instructed persons (IEV 195-04-02) or skilled persons (IEV 195-04-01) only.
These accessories and cable assemblies are intended to be used for circuits specified in IEC 61851 (all parts), which operate at different voltages and frequencies, and which can include extra-low voltage and communication signals.
These accessories and cable assemblies are intended to be used at an ambient temperature between −30 °C and +40 °C.
NOTE 1 In some countries, other requirements can apply.
NOTE 2 In the following country, −35 °C applies: SE.
NOTE 3 The manufacturer can enlarge the temperature range on the condition that the specified range information is provided.
These accessories are intended to be connected only to cables with copper or copper-alloy conductors.
The accessories covered by this document are intended for use in electric vehicle supply equipment in accordance with IEC 61851 (all parts).
This document does not apply to standard plug and socket-outlets used for mode 1 and mode 2 according to IEC 61851-1:2017, 6.2.
NOTE 4 In the following countries, mode 1 is not allowed: UK, US, CA, SG.
- Standard101 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment13 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62196-6:2022 is applicable to vehicle connectors, vehicle inlets and cable assemblies for electric vehicle (EV), intended for use in conductive charging systems which incorporate control means, with a rated operating voltage up to 120 V DC and rated current up to 100 A.
These accessories are intended to be used for a DC interface of the conductive charging system according to IEC 61851-25:2020.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60309-5:2017 applies to a single type of plug, socket-outlet, ship connector and ship inlet, hereinafter referred to as accessories, intended to connect ships to dedicated shore supply systems described in IEC/IEEE 80005-3. This part of IEC 60309 applies to three-phase accessories with an earth contact and with four pilot contacts. This publication is to be read in conjunction with IEC 60309-1:2012.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 62196 applies to EV plugs, EV socket-outlets, vehicle connectors and vehicle inlets with pins and contact-tubes of standardized configurations, herein referred to as accessories. These accessories have a nominal rated operating voltage not exceeding 480 V AC, 50 Hz to 60 Hz, and a rated current not exceeding 63 A three phase or 70 A single phase, for use in conductive charging of electric vehicles. This document covers the basic interface accessories for vehicle supply as specified in IEC 62196-1. NOTE 1 The term "Electric road vehicles (EV)" comprises all road vehicles, including plug-in hybrid road vehicles (PHEV) that derive all or part of their energy from the rechargeable energy storage systems (RESS). These accessories are intended to be used for circuits specified in IEC 61851-1:2017, which operate at different voltages and frequencies, and which can include extra-low voltage (ELV) and communication signals. The use of these accessories for bidirectional power transfer is under consideration. This document applies to accessories to be used in an ambient temperature between -30 °C and +40 °C. NOTE 2 In the following country, other requirements regarding the lower temperature may apply: NO. NOTE 3 In the following country, −35 °C applies: SE. These accessories are intended to be connected only to cables with copper or copper-alloy conductors. Vehicle inlets and vehicle connectors described in this document are intended to be used for charging in modes 1, 2 and 3, cases B and C. The EV socket-outlets and EV plugs covered by this document are intended to be used for charging mode 3 only, case A and B. The modes and permissible connections are specified in IEC 61851-1:2017.
- Standard69 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 62196 is applicable to vehicle couplers with pins and contact tubes of standardized configuration, herein also referred to as "accessories", intended for use in electric vehicle conductive charging systems which incorporate control means, with rated operating voltage and current in accordance with IEC 62196-1:2022. This document applies to high power DC interfaces and combined AC/DC interfaces of vehicle couplers that are intended for use in conductive charging systems for circuits specified in IEC 61851-1:2017 and IEC 6185123:-2. The DC vehicle connectors and inlets covered by this document are used only in charging mode 4, according to IEC 618511:2017, 6.2.4, and case C, as shown in IEC 618511:2017, Figure 3. These vehicle couplers are intended to be used for circuits specified in IEC 61851-23: - which operate at different voltages, and which can include ELV and communication signals. This document applies to the vehicle couplers to be used in an ambient temperature between -30 °C and +40 °C. NOTE 1 In some countries, other requirements may apply. NOTE 2 In the following country, −35 °C applies: SE. These vehicle couplers are intended to be connected only to cables with copper or copper-alloy conductors.
- Standard69 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 62196 is applicable to EV plugs, EV socket-outlets, vehicle connectors, vehicle inlets, herein referred to as "accessories", and to cable assemblies for electric vehicles (EV) intended for use in conductive charging systems which incorporate control means, with a rated operating voltage not exceeding: - 690 V AC 50 Hz to 60 Hz, at a rated current not exceeding 250 A; - 1 500 V DC at a rated current not exceeding 800 A. These accessories and cable assemblies are intended to be installed by instructed persons (IEV 195-04-02) or skilled persons (IEV 195-04-01) only. These accessories and cable assemblies are intended to be used for circuits specified in IEC 61851 (all parts), which operate at different voltages and frequencies, and which can include extra-low voltage and communication signals. These accessories and cable assemblies are intended to be used at an ambient temperature between −30 °C and +40 °C. NOTE 1 In some countries, other requirements can apply. NOTE 2 In the following country, −35 °C applies: SE. NOTE 3 The manufacturer can enlarge the temperature range on the condition that the specified range information is provided. These accessories are intended to be connected only to cables with copper or copper-alloy conductors. The accessories covered by this document are intended for use in electric vehicle supply equipment in accordance with IEC 61851 (all parts). This document does not apply to standard plug and socket-outlets used for mode 1 and mode 2 according to IEC 61851-1:2017, 6.2. NOTE 4 In the following countries, mode 1 is not allowed: UK, US, CA, SG.
- Standard101 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60309-4:2021 applies to self-contained products primarily intended for industrial use, either indoors or outdoors that combine the following items within a single enclosure:
– a fixed or portable socket-outlet according to IEC 60309-1 or IEC 60309-2 with a rated operating voltage not exceeding 1 000 V DC or 1 000 V AC with a frequency not exceeding 500 Hz and a rated current not exceeding 800 A;
– a switching device.
This second edition cancels and replaces the first edition published in 2006 and Amendment 1:2012. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
– updated in order to take into account the technical revisions to IEC 60309-1 and to IEC 60309-2.
This document is to be read in conjunction with IEC 60309-1:2021 and with IEC 60309‑2:2021.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60309-1:2021 applies to plugs, fixed or portable socket-outlets and appliance inlets hereinafter referred to as accessories, with a rated operating voltage not exceeding 1 000 V DC or 1 000 V AC with a frequency not exceeding 500 Hz and a rated current not exceeding 800 A, primarily intended for industrial use, either indoors or outdoors.
This fifth edition cancels and replaces the fourth edition published in 1999, Amendment 1:2005 and Amendment 2:2012. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- addition of classification, requirements and tests for accessories with shutters;
- additional marking to indicate neutral terminal and/or earthing terminal;
- replacement of the term "connector" by the term "portable socket-outlet".
- Standard94 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60309-2:2021 applies to plugs, fixed or portable socket-outlets, and appliance inlets, hereinafter referred to as accessories, with a rated operating voltage not exceeding 1 000 V DC or 1 000 V AC with a frequency not exceeding 500 Hz and a rated current not exceeding 125 A, primarily intended for industrial use, either indoors or outdoors.
This fifth edition cancels and replaces the fourth edition published in 1999, Amendment 1:2005 and Amendment 2:2012. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- addition of requirements and test for non-solid pins;
- additional rating IPX9;
- additional marking to indicate neutral terminal and/or earthing terminal.
This document is to be read in conjunction with IEC 60309-1:2021.
- Standard78 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment13 pagesEnglish languagesale 10% offe-Library read for1 day
IEC PAS 63454:2022 is applicable to vehicle couplers with pins and contact-tubes of standardized configuration (GG), herein also referred to as "accessories", intended for use in electric vehicle conductive charging systems which incorporate control means, with rated operating voltage and current in accordance with IEC 62196-1:2022.
- Technical specification20 pagesEnglish languagesale 15% off
IEC 60799:2018 specifies requirements for cord sets and interconnection cord sets for household and similar general purpose equipment. It does not apply to cord sets for industrial purposes (with plugs and connectors according to IEC 60309) nor to cord extension sets. This third edition cancels and replaces the second edition published in 1998. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- alignment with IEC 60320-1:2015;
- extension to include appliance couplers in accordance with IEC 60320-2-3;
- (Under preparation. Stage at the time of publication: IEC/FDIS 60320-2-3:2018)
- Standard35 pagesEnglish languagesale 15% off
- Standard22 pagesEnglish and French languagesale 15% off
- Standard50 pagesEnglish and French languagesale 15% off
- Technical report15 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard10 pagesEnglish and French languagesale 15% off
IEC 62196-2:2022 applies to EV plugs, EV socket-outlets, vehicle connectors and vehicle inlets with pins and contact-tubes of standardized configurations, herein referred to as accessories. These accessories have a nominal rated operating voltage not exceeding 480 V AC, 50 Hz to 60 Hz, and a rated current not exceeding 63 A three phase or 70 A single phase, for use in conductive charging of electric vehicles.
This document covers the basic interface accessories for vehicle supply as specified in IEC 62196-1.
This third edition cancels and replaces the second edition published in 2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
interchangeability requirements have been removed from the title of Part 2;
alignment with IEC 62196-1:2022 and IEC 62196-3:2022;
alignment with IEC 61851-1:2017.
- Standard134 pagesEnglish and French languagesale 15% off
IEC 62196-3:2022 is applicable to vehicle couplers with pins and contact tubes of standardized configuration, herein also referred to as "accessories", intended for use in electric vehicle conductive charging systems which incorporate control means, with rated operating voltage and current in accordance with IEC 62196-1:2022.
This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
interchangeability requirements have been removed from the title of Part 3;
increased ratings for all configurations;
reference to new tests in IEC 62196-1 (Clauses 34, 35, 36 and 37).
- Standard132 pagesEnglish and French languagesale 15% off
IEC TS 62196-4:2022(E) is applicable to plugs, socket-outlets, vehicle connectors and vehicle inlets, herein referred to as “accessories”, of standardized configuration for DC power supply of electric road vehicles, where the protection against electric shocks relies on double or reinforced insulation between all AC and DC inputs and outputs of the EV supply equipment, intended for use in conductive power supply systems which can incorporate control means, with a maximum operating voltage up to 120 V DC, not exceeding 60 A.
- Technical specification56 pagesEnglish languagesale 15% off
- Standard21 pagesEnglish and French languagesale 15% off
lEC 60320-3:2014 sets the dimensions for appliance couplers for two poles and two poles with earth contact:
- for the connection of electrical devices for household and similar onto the mains supply and
- for the interconnection of the electrical supply to appliance or equipment
- and dimensions for gauges.
This publication is to be read in conjunction with IEC 60320-1:2007.
- Standard161 pagesEnglish and French languagesale 15% off
- Standard380 pagesEnglish and French languagesale 15% off
- Standard420 pagesEnglish and French languagesale 15% off
IEC 60884-1:2022 applies to plugs and fixed or portable socket-outlets for AC only, with or without earthing contact, with a rated voltage greater than 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors.
Compatible plugs and socket-outlets, when combined, form a plug and socket-outlet system. Standardized systems used around the world are reported in IEC/TR 60083.
The rated current is limited to 16 A maximum for accessories provided with screwless-type terminals.
This fourth edition cancels and replaces the third edition published in 2002, Amendment 1:2006 and Amendment 2:2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
plugs and socket-outlets incorporating pilot lights;
crimped connections in accessories;
insulation piercing terminals (IPT);
accessories to be used with American Wire Gauge (AWG) cables;
accessories used in T° below −5 °C down to and including −45 °C;
accessories used in T° above +40 °C up to and including +70 °C;
plugs and socket-outlets for high load (HL);
clarification of some definitions;
durability of markings test;
introduction of thermal monitoring in the plug;
requirements for shutters in portable socket-outlets;
test walls for the verification of ingress of water;
rewriting of the temperature rise clause.
The contents of the corrigendum of November 2023 have been included in this copy.
- Standard196 pagesEnglish languagesale 15% off
- Standard410 pagesEnglish and French languagesale 15% off
IEC 60309-2:2021 applies to plugs, fixed or portable socket-outlets, and appliance inlets, hereinafter referred to as accessories, with a rated operating voltage not exceeding 1 000 V DC or 1 000 V AC with a frequency not exceeding 500 Hz and a rated current not exceeding 125 A, primarily intended for industrial use, either indoors or outdoors. This fifth edition cancels and replaces the fourth edition published in 1999, Amendment 1:2005 and Amendment 2:2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
addition of requirements and test for non-solid pins;
additional rating IPX9;
additional marking to indicate neutral terminal and/or earthing terminal. This document is to be read in conjunction with IEC 60309-1:2021.
- Standard78 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60309-4:2021 applies to self-contained products primarily intended for industrial use, either indoors or outdoors that combine the following items within a single enclosure: – a fixed or portable socket-outlet according to IEC 60309-1 or IEC 60309-2 with a rated operating voltage not exceeding 1 000 V DC or 1 000 V AC with a frequency not exceeding 500 Hz and a rated current not exceeding 800 A; – a switching device. This second edition cancels and replaces the first edition published in 2006 and Amendment 1:2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: – updated in order to take into account the technical revisions to IEC 60309-1 and to IEC 60309-2. This document is to be read in conjunction with IEC 60309-1:2021 and with IEC 60309‑2:2021.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60309-1:2021 applies to plugs, fixed or portable socket-outlets and appliance inlets hereinafter referred to as accessories, with a rated operating voltage not exceeding 1 000 V DC or 1 000 V AC with a frequency not exceeding 500 Hz and a rated current not exceeding 800 A, primarily intended for industrial use, either indoors or outdoors. This fifth edition cancels and replaces the fourth edition published in 1999, Amendment 1:2005 and Amendment 2:2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
addition of classification, requirements and tests for accessories with shutters;
additional marking to indicate neutral terminal and/or earthing terminal;
replacement of the term "connector" by the term "portable socket-outlet".
- Standard94 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62196-6:2022 is applicable to vehicle connectors, vehicle inlets and cable assemblies for electric vehicle (EV), intended for use in conductive charging systems which incorporate control means, with a rated operating voltage up to 120 V DC and rated current up to 100 A. These accessories are intended to be used for a DC interface of the conductive charging system according to IEC 61851-25:2020.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62196-1:2022 is applicable to EV plugs, EV socket-outlets, vehicle connectors, vehicle inlets, herein referred to as "accessories", and to cable assemblies for electric vehicles (EV) intended for use in conductive charging systems which incorporate control means, with a rated operating voltage not exceeding:
690 V AC 50 Hz to 60 Hz, at a rated current not exceeding 250 A;
1 500 V DC at a rated current not exceeding 800 A.
This fourth edition cancels and replaces the third edition published in 2014. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
deletion of references to universal AC and DC interfaces;
additional requirements for contact materials and plating;
changes to the temperature rise test to include additional points of measurement;
additional tests for accessories to address thermal stresses and stability, mechanical wear and abuse, and exposure to contaminants;
relocation of information and requirements for DC charging to IEC 62196-3.
- Standard125 pagesEnglish languagesale 15% off
- Standard192 pagesEnglish and French languagesale 15% off
IEC 62196-6:2022 is applicable to vehicle connectors, vehicle inlets and cable assemblies for electric vehicle (EV), intended for use in conductive charging systems which incorporate control means, with a rated operating voltage up to 120 V DC and rated current up to 100 A.
These accessories are intended to be used for a DC interface of the conductive charging system according to IEC 61851-25:2020.
- Standard53 pagesEnglish and French languagesale 15% off
This part of lEC 60320 sets the general requirements for appliance couplers for two poles and two poles with earth contact and for the connection of electrical devices for household and similar onto the mains supply.
This part of lEC 60320 is also valid for appliance inlets/appliance outlets integrated or incorporated in appliances.
The rated voltage does not exceed 250 V (a.c.) and the rated current does not exceed 16 A.
Appliance couplers complying with this part of lEC 60320 are suitable for normal use at ambient temperatures not normally exceeding +40 °C, but their average over a period of 24 h does not exceed +35 °C, with a lower limit of the ambient air temperature of -5 °C.
Annex E provides test requirements for derating the operating current of an accessory when used in ambient temperatures above +35 °C up to +90 °C.
Appliance couplers are not suitable for
- use in place of plug and socket-outlet systems according to IEC 60884-1.
- use in place of devices for connecting luminaires (DCLs) according to IEC 61995 or 306 luminaire supporting couplers (LSCs). 307
NOTE Requirements for d.c. are under consideration.
- Standard74 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies requirements for the shore supply system for auxiliaries and pre-conditioning and the related intermateable connector pairs. This standard specifies the characteristics of the connectors in order to achieve interoperability at the rolling-stock/shore power supply interface.
This document does not apply to shore supplies to move the rolling stock.
- Corrigendum1 pageEnglish languagesale 10% offe-Library read for1 day
This part of lEC 60320 sets the general requirements for appliance couplers for two poles and two poles with earth contact and for the connection of electrical devices for household and similar onto the mains supply. This part of lEC 60320 is also valid for appliance inlets/appliance outlets integrated or incorporated in appliances. The rated voltage does not exceed 250 V (a.c.) and the rated current does not exceed 16 A. Appliance couplers complying with this part of lEC 60320 are suitable for normal use at ambient temperatures not normally exceeding +40 °C, but their average over a period of 24 h does not exceed +35 °C, with a lower limit of the ambient air temperature of -5 °C. Annex E provides test requirements for derating the operating current of an accessory when used in ambient temperatures above +35 °C up to +90 °C. Appliance couplers are not suitable for - use in place of plug and socket-outlet systems according to IEC 60884-1. - use in place of devices for connecting luminaires (DCLs) according to IEC 61995 or 306 luminaire supporting couplers (LSCs). 307 NOTE Requirements for d.c. are under consideration.
- Standard74 pagesEnglish languagesale 10% offe-Library read for1 day