2009/142/EC - DIRECTIVE 2009/142/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 30 November 2009 relating to appliances burning gaseous fuels
DIRECTIVE 2009/142/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 30 November 2009 relating to appliances burning gaseous fuels
Direktiva 2009/142/ES Evropskega parlamenta in Sveta z dne 30. novembra 2009 v zvezi z napravami na plinsko gorivo
Seznam harmoniziranih evropskih standardov in istovetnih slovenskih standardov, katerih uporaba ustvarja domnevo o skladnosti proizvoda z zahtevami direktive Sveta 2009/142/EC
General Information
This document specifies the requirements and test methods for the construction, safety, and marking of decorative fuel effect gas appliances not exceeding a nominal heat input of 20 kW (based on the net calorific value), thereafter referred to as appliances.
This document is applicable to appliances that are designed to simulate a solid fuel fire and incorporate a natural draught burner with or without an ignition burner, that uses one or more combustible gases of the three gas families at the pressures stated in EN 437:2021. The appliances are for decorative purposes only and are not heating appliances.
This document is applicable to type BAS, as described in 4.2, decorative fuel effect gas appliances that are designed to be installed within a non-combustible builder's opening or a non-combustible fireplace recess.
NOTE 1 This document specifies special national conditions in Annex C for appliances of category I2E+, marketed in Belgium.
NOTE 2 This document specifies special A-deviations in Annex D for appliances in Switzerland which require additional requirements for subclauses 6.6 and 6.7.
This document includes additional requirements for Type BBS appliances which are specified in Annex F.
In addition, this document is applicable to decorative fuel-effect gas appliances that are designed to be installed under a non-combustible canopy which is independent or integral with a flue box, for which additional requirements are specified in Annex A.
The use of toxic gases is not covered.
This document is not applicable to:
- catalytic combustion appliances;
- appliances in which the supply of combustion air and/or the evacuation of products of combustion is achieved by mechanical means.
NOTE 3 Requirements concerning the rational use of energy have not been included in this document, because the appliances are for decorative purposes.
- Standard75 pagesEnglish languagesale 10% offe-Library read for1 day
This standard specifies requirements and methods of test for lubricants to be used in gas appliances of all categories including auxilliary equipment mounted or intended to be mounted on such appliances and which may be in contact with combustible gases, except those designed for use in industrial processes.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements and test methods for the construction, safety, and marking of decorative fuel effect gas appliances not exceeding a nominal heat input of 20 kW (based on the net calorific value), thereafter referred to as appliances.
This document is applicable to appliances that are designed to simulate a solid fuel fire and incorporate a natural draught burner with or without an ignition burner, that uses one or more combustible gases of the three gas families at the pressures stated in EN 437:2021. The appliances are for decorative purposes only and are not heating appliances.
This document is applicable to type BAS, as described in 4.2, decorative fuel effect gas appliances that are designed to be installed within a non-combustible builder's opening or a non-combustible fireplace recess.
NOTE 1 This document specifies special national conditions in Annex C for appliances of category I2E+, marketed in Belgium.
NOTE 2 This document specifies special A-deviations in Annex D for appliances in Switzerland which require additional requirements for subclauses 6.6 and 6.7.
This document includes additional requirements for Type BBS appliances which are specified in Annex F.
In addition, this document is applicable to decorative fuel-effect gas appliances that are designed to be installed under a non-combustible canopy which is independent or integral with a flue box, for which additional requirements are specified in Annex A.
The use of toxic gases is not covered.
This document is not applicable to:
- catalytic combustion appliances;
- appliances in which the supply of combustion air and/or the evacuation of products of combustion is achieved by mechanical means.
NOTE 3 Requirements concerning the rational use of energy have not been included in this document, because the appliances are for decorative purposes.
- Standard75 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the terminology, the general requirements for the construction and operation of forced draught gas burners and also the provision of control and safety devices, and the test procedure for these burners.
This European Standard is applicable to:
- automatic gas burners with a combustion air fan (hereinafter called "burners") and gas line components, intended for use in appliances of different types, and that are operated with gaseous fuels;
- pre mixed burners and nozzle mixed burners;
- single burners with a single combustion chamber;
- single fuel and dual fuel burners when operating only on gas;
- the gas function of dual-fuel burners designed to operate simultaneously on gaseous and liquid fuels, which, for the latter, the requirements of EN 267 also apply.
This European Standard deals with all significant machine hazards, hazardous situations and events relevant to burners, when they are used as intended and under conditions of misuse which are reasonably foreseeable, see Annex J.
This European Standard specifies the requirements to ensure the safety during commissioning, start-up, operation, shut-down and maintenance.
This European Standard does not apply to burners specifically designed for use in industrial processes carried out on industrial premises.
This European Standard deals also with the additional requirements for the burners in the scope with pressurised parts and /or firing pressurised bodies, see Annex K.
This European Standard deals also with forced draught burners intended to be used with biogenous gaseous fuels, mixtures with line-conveyed gas and special gaseous fuels.
This European Standard deals also with burners and their equipment to increase the total appliance efficiency, see Annex M.
- Standard147 pagesEnglish languagesale 10% offe-Library read for1 day
2019-01-10 AJC: Document uploaded to HAS platform for FV stage following failed original upload. New HAS deadline: 2019-02-14. Following reception of results, document will progress.
2017-07-17 CP: negative assessment recived - UAP cancelled
2021: CLC legacy converted by DCLab NISOSTS
- Amendment28 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements and test methods for the safety and efficiency of gas fired air heaters with or without a fan to assist the transportation of combustion air and/or flue gases, hereafter referred to as "appliances".
This standard also applies to warm air heaters having forced draught burners.
This European Standard applies to Type A2, A3 appliances, with an input not exceeding 300 kW (net CV basis), intended for non-domestic use.
This European Standard also applies to Type B11, B11AS, B11BS, B12, B12AS, B12BS, B13, B13AS, B13BS, B14, B14AS, B14BS, B22, B23, B41, B41AS, B41BS, B42, B42AS, B42BS, B43, B43AS, B43BS, B44, B44AS, B44BS, B52, B53, C11, C12, C13, C21, C31, C32, C33, C41, C62 and C63 appliances with an input not exceeding 300 kW (net CV basis), intended for domestic and non-domestic use.
Provision of the heated air may be by means of ducting.
This European Standard does not apply to:
a) dual purpose air conditioning appliances (heating and cooling);
b) appliances where the air is heated by an intermediate fluid;
c) portable or transportable forced convection appliances;
d) appliances fitted with manual or automatic means of adjusting the combustion products evacuation by means of flue dampers;
e) appliances having multiple heating units with a single draught diverter;
f) appliances fitted with more than one flue outlet;
g) appliances fitted with gas boosters;
h) C21 and C41 appliances for 3rd family gases.
NOTE For C41 appliances, see all requirements and test methods that are valid for C21 appliances, unless otherwise stated.
This European Standard is not intended to cover appliances projected for connection to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance.
This European Standard is applicable to appliances which are intended to be type tested.
- Standard193 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the terminology, the general requirements for the construction and operation of forced draught gas burners and also the provision of control and safety devices, and the test procedure for these burners.
This European Standard is applicable to:
- automatic gas burners with a combustion air fan (hereinafter called "burners") and gas line components, intended for use in appliances of different types, and that are operated with gaseous fuels;
- pre mixed burners and nozzle mixed burners;
- single burners with a single combustion chamber;
- single fuel and dual fuel burners when operating only on gas;
- the gas function of dual-fuel burners designed to operate simultaneously on gaseous and liquid fuels, which, for the latter, the requirements of EN 267 also apply.
This European Standard deals with all significant machine hazards, hazardous situations and events relevant to burners, when they are used as intended and under conditions of misuse which are reasonably foreseeable, see Annex J.
This European Standard specifies the requirements to ensure the safety during commissioning, start-up, operation, shut-down and maintenance.
This European Standard does not apply to burners specifically designed for use in industrial processes carried out on industrial premises.
This European Standard deals also with the additional requirements for the burners in the scope with pressurised parts and /or firing pressurised bodies, see Annex K.
This European Standard deals also with forced draught burners intended to be used with biogenous gaseous fuels, mixtures with line-conveyed gas and special gaseous fuels.
This European Standard deals also with burners and their equipment to increase the total appliance efficiency, see Annex M.
- Standard147 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements and test methods for the safety and efficiency of gas fired air heaters with or without a fan to assist the transportation of combustion air and/or flue gases, hereafter referred to as "appliances".
This standard also applies to warm air heaters having forced draught burners.
This European Standard applies to Type A2, A3 appliances, with an input not exceeding 300 kW (net CV basis), intended for non-domestic use.
This European Standard also applies to Type B11, B11AS, B11BS, B12, B12AS, B12BS, B13, B13AS, B13BS, B14, B14AS, B14BS, B22, B23, B41, B41AS, B41BS, B42, B42AS, B42BS, B43, B43AS, B43BS, B44, B44AS, B44BS, B52, B53, C11, C12, C13, C21, C31, C32, C33, C41, C62 and C63 appliances with an input not exceeding 300 kW (net CV basis), intended for domestic and non-domestic use.
Provision of the heated air may be by means of ducting.
This European Standard does not apply to:
a) dual purpose air conditioning appliances (heating and cooling);
b) appliances where the air is heated by an intermediate fluid;
c) portable or transportable forced convection appliances;
d) appliances fitted with manual or automatic means of adjusting the combustion products evacuation by means of flue dampers;
e) appliances having multiple heating units with a single draught diverter;
f) appliances fitted with more than one flue outlet;
g) appliances fitted with gas boosters;
h) C21 and C41 appliances for 3rd family gases.
NOTE For C41 appliances, see all requirements and test methods that are valid for C21 appliances, unless otherwise stated.
This European Standard is not intended to cover appliances projected for connection to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance.
This European Standard is applicable to appliances which are intended to be type tested.
- Standard193 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and test methods for the construction, safety, fitness
for purpose, rational use of energy and the marking of a micro combined heat and power appliance;
(hereafter referred to as “mCHP appliance”).
This European Standard applies to mCHP appliances of types B22, B23, B32, B33, B52, B53, C1, C3, C42, C43
C52, C53, C62, C63, C82, C83 and C9 based on the classifications of CEN/TR 1749:
– that use one or more supplied gases of the three gas families at the pressures stated in EN 437,
– where the temperature of the heat transfer fluid of the heating system (heating water circuit) does
not exceed 105 ºC during normal operation,
– where the maximum operating pressure in the
- heating water circuit does not exceed 6 bar,
- domestic hot water circuit (if installed) does not exceed 10 bar,
– which are either intended to be installed indoors or outdoors in a partially protected place,
– which are intended to produce hot water either by the instantaneous or storage principle,
– which have a maximum heat input (based on net calorific value) not exceeding 70 kW,
– which are designed for sealed or open water systems.
NOTE 1 For applications where the maximum allowable water temperature exceeds 110 ºC or where volume multiplied by
maximum allowable pressure exceeds 50 bar litres, further requirements may be necessary to comply with the essential
requirements of Directive 97/23/EC (Pressure Equipment Directive (PED)).
NOTE 2 For mCHP appliances with constructions that might not be fully covered by this European Standard or by another specific
standard, the risk associated with the alternative construction will be assessed.
NOTE 3 prEN 13203-4 will specify the assessment of energy consumption for domestic hot water production of gas combined
heat and power appliances (mCHP).
This European Standard does not contain the requirements necessary for appliance capable of producing
electrical energy without using the thermal energy.
This European Standard does not cover all the requirements for mCHP appliances that are intended to be
connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the
lifetime of the appliance (see Annex DD).
- Amendment28 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies constructional and performance characteristics, safety specifications and rational use of energy, relevant test methods and marking of independent stoves, side burners, covered burners, open burners, griddles, radiant grills, burning liquefied petroleum gas, referred to in the body of the text as "appliances".
This document covers appliances, used outdoors and operating with the gases of the third family according to EN 437:2018.
Appliances used in leisure vehicles and boats are outside the field of application of this standard.
Independent stove burners, whose nominal heat input is below 1,16 kW, griddles and radiant grills, are not subject to any special requirement concerning the rational use of energy due to their low rate and their use for short periods of time.
This document does not state all requirements for appliances of other nature incorporating a stove (for example barbecues are not covered by this standard but a side burner of a barbecue is covered by this standard).
This document does not cover regulators that are used with those appliances.
- Standard54 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the general safety, design, construction, and performance requirements and testing of safety, control or regulating devices (hereafter referred to as controls) for burners and appliances burning one or more gaseous fuels or liquid fuels. This European Standard is applicable to controls with declared maximum inlet pressure up to and including 500 kPa and of nominal connection sizes up to and including DN 250.
This European standard specifies general product requirements for the following controls:
— automatic shut-off valves;
— automatic burner control systems;
— flame supervision devices;
— gas/air ratio controls;
— pressure regulators;
— manual taps;
— mechanical thermostats;
— multifunctional controls;
— pressure sensing devices;
— valve proving systems;
— automatic vent valves.
This European standard applies for control functions that are not covered by a specific control standard for burners and appliances burning one or more gaseous fuels or liquid fuels.
This European Standard applies also for safety accessories and pressure accessories with a product of the maximum allowable pressure PS and the volume V of less than 600 000 kPa · dm3 (6 000 bar · L) or with a product of PS and DN of less than 300 000 kPa (3 000 bar).
This European Standard applies for AC and DC supplied controls (for controls supplied by stand-alone battery system, battery systems for mobile applications or systems which are intended to be connected to DC supply networks controls see Annex I).
This European Standard is applicable to reset functions used for reset from lockout, e.g. due to ignition failure or temperature cut-out in burners and appliances (see Annex M).
This European Standard establishes methodologies for the determination of a Safety Integrity Level (SIL) and the determination of a Performance Level (PL) (see Annex J, Annex K and Annex L).
This European Standard gives guidelines for environmental aspects (see Annex N).
This European Standard does not apply to mechanical controls for use with liquid fuels.
The protection against environmental impact in open air (i.e. capable of withstanding UV radiation, wind, rain, snow, dirt deposits, condensation, ice and hoar frost (see IEV 441-11-05:2005), earthquake and external fire) is not covered by this standard.
This European Standard should be used in conjunction with the specific control standard (see Bibliography).
- Standard153 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the general safety, design, construction, and performance requirements and testing of safety, control or regulating devices (hereafter referred to as controls) for burners and appliances burning one or more gaseous fuels or liquid fuels. This European Standard is applicable to controls with declared maximum inlet pressure up to and including 500 kPa and of nominal connection sizes up to and including DN 250.
This European standard specifies general product requirements for the following controls:
— automatic shut-off valves;
— automatic burner control systems;
— flame supervision devices;
— gas/air ratio controls;
— pressure regulators;
— manual taps;
— mechanical thermostats;
— multifunctional controls;
— pressure sensing devices;
— valve proving systems;
— automatic vent valves.
This European standard applies for control functions that are not covered by a specific control standard for burners and appliances burning one or more gaseous fuels or liquid fuels.
This European Standard applies also for safety accessories and pressure accessories with a product of the maximum allowable pressure PS and the volume V of less than 600 000 kPa · dm3 (6 000 bar · L) or with a product of PS and DN of less than 300 000 kPa (3 000 bar).
This European Standard applies for AC and DC supplied controls (for controls supplied by stand-alone battery system, battery systems for mobile applications or systems which are intended to be connected to DC supply networks controls see Annex I).
This European Standard is applicable to reset functions used for reset from lockout, e.g. due to ignition failure or temperature cut-out in burners and appliances (see Annex M).
This European Standard establishes methodologies for the determination of a Safety Integrity Level (SIL) and the determination of a Performance Level (PL) (see Annex J, Annex K and Annex L).
This European Standard gives guidelines for environmental aspects (see Annex N).
This European Standard does not apply to mechanical controls for use with liquid fuels.
The protection against environmental impact in open air (i.e. capable of withstanding UV radiation, wind, rain, snow, dirt deposits, condensation, ice and hoar frost (see IEV 441-11-05:2005), earthquake and external fire) is not covered by this standard.
This European Standard should be used in conjunction with the specific control standard (see Bibliography).
- Standard153 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies constructional and performance characteristics, safety specifications and rational use of energy, relevant test methods and marking of independent stoves, side burners, covered burners, open burners, griddles, radiant grills, burning liquefied petroleum gas, referred to in the body of the text as "appliances".
This document covers appliances, used outdoors and operating with the gases of the third family according to EN 437:2018.
Appliances used in leisure vehicles and boats are outside the field of application of this standard.
Independent stove burners, whose nominal heat input is below 1,16 kW, griddles and radiant grills, are not subject to any special requirement concerning the rational use of energy due to their low rate and their use for short periods of time.
This document does not state all requirements for appliances of other nature incorporating a stove (for example barbecues are not covered by this standard but a side burner of a barbecue is covered by this standard).
This document does not cover regulators that are used with those appliances.
- Standard54 pagesEnglish languagesale 10% offe-Library read for1 day
This European standard specifies the design, safety and marking requirements and test methods for flueless patio heaters for outdoor or amply ventilated area use only.
These appliances are for use exclusively with gases of the third family as defined in Clause 4.
This European standard applies to appliances that have a nominal heat input not exceeding 17 kW (based on the gross calorific value), supplied with a maximum inlet pressure of 50 mbar:
- fixed or,
- movable, including those which comprise a housing for a transportable and rechargeable liquefied petroleum gas cylinder.
This European standard does not apply to appliances equipped with a fan for either combustion or circulation of the convection air.
This European standard does not cover LPG containers for liquefied petroleum gas, their associated regulator, tubing and flexible hoses used for gas supply of appliances covered by this European standard. Regulator, tubing and flexible hoses are covered by others standards (EN 16129, EN 16436-1 and prEN 16436-2, etc.) and national regulations.
This European standard does not lay down any specific requirements for the thermal efficiency of this type of appliances, but the requirements relating to combustion, which is a safety matter, ensure that the gas fuel will burn efficiently. However a method to measure the performance is described in informative Annex B.
- Standard44 pagesEnglish languagesale 10% offe-Library read for1 day
This European standard specifies the design, safety and marking requirements and test methods for flueless patio heaters for outdoor or amply ventilated area use only.
These appliances are for use exclusively with gases of the third family as defined in Clause 4.
This European standard applies to appliances that have a nominal heat input not exceeding 17 kW (based on the gross calorific value), supplied with a maximum inlet pressure of 50 mbar:
- fixed or,
- movable, including those which comprise a housing for a transportable and rechargeable liquefied petroleum gas cylinder.
This European standard does not apply to appliances equipped with a fan for either combustion or circulation of the convection air.
This European standard does not cover LPG containers for liquefied petroleum gas, their associated regulator, tubing and flexible hoses used for gas supply of appliances covered by this European standard. Regulator, tubing and flexible hoses are covered by others standards (EN 16129, EN 16436-1 and prEN 16436-2, etc.) and national regulations.
This European standard does not lay down any specific requirements for the thermal efficiency of this type of appliances, but the requirements relating to combustion, which is a safety matter, ensure that the gas fuel will burn efficiently. However a method to measure the performance is described in informative Annex B.
- Standard44 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and test methods for the construction, safety, fitness for purpose, rational use of energy and the marking of a micro combined heat and power appliance; (hereafter referred to as “mCHP appliance”). This European Standard applies to mCHP appliances of types B22, B23, B32, B33, B52, B53, C1, C3, C42, C43 C52, C53, C62, C63, C82, C83 and C9 based on the classifications of CEN/TR 1749: – that use one or more supplied gases of the three gas families at the pressures stated in EN 437, – where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 ºC during normal operation, – where the maximum operating pressure in the - heating water circuit does not exceed 6 bar, - domestic hot water circuit (if installed) does not exceed 10 bar, – which are either intended to be installed indoors or outdoors in a partially protected place, – which are intended to produce hot water either by the instantaneous or storage principle, – which have a maximum heat input (based on net calorific value) not exceeding 70 kW, – which are designed for sealed or open water systems. NOTE 1 For applications where the maximum allowable water temperature exceeds 110 ºC or where volume multiplied by maximum allowable pressure exceeds 50 bar litres, further requirements may be necessary to comply with the essential requirements of Directive 97/23/EC (Pressure Equipment Directive (PED)). NOTE 2 For mCHP appliances with constructions that might not be fully covered by this European Standard or by another specific standard, the risk associated with the alternative construction will be assessed. NOTE 3 This EN includes formulae and methods intended to produce values required by implementation measures of the ErP Directive 2009/125/EC and Labelling Directive 2010/30/EU. NOTE 4 EN 13203-4 will specify the assessment of energy consumption for domestic hot water production of gas combined heat and power appliances (mCHP). This European Standard does not contain the requirements necessary for appliance capable of producing electrical energy without using the thermal energy. This European Standard does not cover all the requirements for mCHP appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex DD).
- Standard170 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the test methods and requirements for the construction and operating characteristics relating to the safety, rational use of energy and marking, of commercial gas heated boiling pans.
This European Standard only covers type testing.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard defines the constructional and operational characteristics, the safety requirements, test methods and the marking of regulators and automatic change-over devices having a maximum regulated pressure of 4 bar, with a maximum capacity of 150 kg/h, for use with butane, propane and their mixtures in the vapour phase.
This European Standard also applies to the safety devices which are included within regulating devices covered by this standard. The characteristics of these safety devices are given in Annexes A and B.
This European Standard also includes the requirements for:
- adaptors for connecting to self closing valves;
- auxiliary safety devices.
For the purpose of this European Standard:
- regulators and automatic change-over devices are referred to as "regulating devices";
- regulators, automatic change-over devices and adaptors are referred to as "devices".
The requirements apply to devices used in locations where the temperature likely to be reached during use is between -20 °C and +50 °C. Additional requirements for devices to be used at temperatures below –20 °C are given in Annex C.
Additional requirements for regulating devices intended to be used in caravans, motor caravans and freshwater boats are given in Annex D.
Additional requirements for regulating devices intended to be used in seawater boats are given in Annex M.
For specific use in caravans motor caravans and boats (freshwater and seawater), the automatic change over device function may also be carried out by an assembly of regulators, forming an "automatic change over device system" as defined in 3.1.9.
For installation rules of devices and their possible associated safety devices, reference should be made to national regulations in force in the member countries.
All connections and the countries in which they are used are given in Annexes G and H.
This European Standard defines only specific connections which are not defined in other standards (e.g. EN 15202 for cylinder valve connections).
- Standard138 pagesEnglish languagesale 10% offe-Library read for1 day
TC - Clarification in layout needed in Table
- Standard2 pagesEnglish languagesale 10% offe-Library read for1 day
TC - Clarification in layout needed in Table
- Standard2 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard defines the specifications and test methods for the construction, safety, rational use of energy and fitness for purpose, environment and classification and marking of gas-fired storage water heaters for domestic hot water uses, hereafter called "appliance".
This European Standard applies to appliances:
- of types B11, B11BS, C11, C12, C13, C21, C31,, C32, C33, C42, C43, C51,C52, C53, C62, C63, C72, C73, C81 connected to an individual flue duct, C82 and C83 according to CEN/TR 1749;
- fitted with atmospheric burners;
- using one or more combustible gases corresponding to the three gas families and the pressures indicated in EN 437;
- of nominal heat input not exceeding 150 kW (net calorific value);
- fitted with electrically operated mechanical flue dampers that are positioned downstream of the heat exchanger.
- Standard159 pagesEnglish languagesale 10% offe-Library read for1 day
1.1 Scope of EN 12309 series
Appliances covered by this European Standard include one or a combination of the following:
― gas fired sorption chiller;
― gas fired sorption chiller/heater;
― gas fired sorption heat pump.
This European Standard applies to appliances only when used for space heating and cooling with or without heat recovery.
This European Standard applies to appliances having flue gas systems of type B and C (according to CEN/TR 1749) and to appliances designed for outdoor installations. EN 12309 does not apply to air conditioners, it only applies to appliances having:
― integral burners under the control of fully automatic burner control systems;
― closed system refrigerant circuits in which the refrigerant does not come into direct contact with the water or air to be cooled or heated;
― mechanical means to assist transportation of the combustion air and/or the flue gas.
The above appliances can have one or more primary or secondary functions (i.e. heat recovery - see definitions in prEN 12309 1:2012). In the case of packaged units (consisting of several parts), the standard applies only to those designed and supplied as a complete package.
The appliances having their condenser cooled by air and by the evaporation of external additional water are not covered by this European Standard.
Installations used for heating and/or cooling of industrial processes are not within the scope of these standards.
NOTE All the symbols given in this text are used regardless of the language used.
1.2 Scope of this Part 2 to EN 12309
This part of EN 12309 deals with the safety of gas-driven sorption heat pumps as defined in prEN 12309 1. Only types B12 for outdoor installations, B13 for outdoor installations, B22 for outdoor installations, B23 for outdoor installations, C12 and C13, C32 and C33 are covered in this European Standard.
- Standard102 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard defines the specifications and test methods for the construction, safety, rational use of energy and fitness for purpose, environment and classification and marking of gas-fired storage water heaters for domestic hot water uses, hereafter called "appliance".
This European Standard applies to appliances:
- of types B11, B11BS, C11, C12, C13, C21, C31,, C32, C33, C42, C43, C51,C52, C53, C62, C63, C72, C73, C81 connected to an individual flue duct, C82 and C83 according to CEN/TR 1749;
- fitted with atmospheric burners;
- using one or more combustible gases corresponding to the three gas families and the pressures indicated in EN 437;
- of nominal heat input not exceeding 150 kW (net calorific value);
- fitted with electrically operated mechanical flue dampers that are positioned downstream of the heat exchanger.
- Standard159 pagesEnglish languagesale 10% offe-Library read for1 day
1.1 Scope of EN 12309 series
Appliances covered by this European Standard include one or a combination of the following:
― gas fired sorption chiller;
― gas fired sorption chiller/heater;
― gas fired sorption heat pump.
This European Standard applies to appliances only when used for space heating and cooling with or without heat recovery.
This European Standard applies to appliances having flue gas systems of type B and C (according to CEN/TR 1749) and to appliances designed for outdoor installations. EN 12309 does not apply to air conditioners, it only applies to appliances having:
― integral burners under the control of fully automatic burner control systems;
― closed system refrigerant circuits in which the refrigerant does not come into direct contact with the water or air to be cooled or heated;
― mechanical means to assist transportation of the combustion air and/or the flue gas.
The above appliances can have one or more primary or secondary functions (i.e. heat recovery - see definitions in prEN 12309 1:2012). In the case of packaged units (consisting of several parts), the standard applies only to those designed and supplied as a complete package.
The appliances having their condenser cooled by air and by the evaporation of external additional water are not covered by this European Standard.
Installations used for heating and/or cooling of industrial processes are not within the scope of these standards.
NOTE All the symbols given in this text are used regardless of the language used.
1.2 Scope of this Part 2 to EN 12309
This part of EN 12309 deals with the safety of gas-driven sorption heat pumps as defined in prEN 12309 1. Only types B12 for outdoor installations, B13 for outdoor installations, B22 for outdoor installations, B23 for outdoor installations, C12 and C13, C32 and C33 are covered in this European Standard.
- Standard102 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and test methods for the construction, safety, fitness for purpose, rational use of energy and the marking of a micro combined heat and power appliance; (hereafter referred to as “mCHP appliance”).
This European Standard applies to mCHP appliances of types B22, B23, B32, B33, B52, B53, C1, C3, C42, C43 C52, C53, C62, C63, C82, C83 and C9 based on the classifications of CEN/TR 1749:
– that use one or more supplied gases of the three gas families at the pressures stated in EN 437,
– where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 ºC during normal operation,
– where the maximum operating pressure in the
- heating water circuit does not exceed 6 bar,
- domestic hot water circuit (if installed) does not exceed 10 bar,
– which are either intended to be installed indoors or outdoors in a partially protected place,
– which are intended to produce hot water either by the instantaneous or storage principle,
– which have a maximum heat input (based on net calorific value) not exceeding 70 kW,
– which are designed for sealed or open water systems.
NOTE 1 For applications where the maximum allowable water temperature exceeds 110 ºC or where volume multiplied by maximum allowable pressure exceeds 50 bar litres, further requirements may be necessary to comply with the essential requirements of Directive 97/23/EC (Pressure Equipment Directive (PED)).
NOTE 2 For mCHP appliances with constructions that might not be fully covered by this European Standard or by another specific standard, the risk associated with the alternative construction will be assessed.
NOTE 3 This EN includes formulae and methods intended to produce values required by implementation measures of the ErP Directive 2009/125/EC and Labelling Directive 2010/30/EU.
NOTE 4 EN 13203-4 will specify the assessment of energy consumption for domestic hot water production of gas combined heat and power appliances (mCHP).
This European Standard does not contain the requirements necessary for appliance capable of producing electrical energy without using the thermal energy.
This European Standard does not cover all the requirements for mCHP appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex DD).
- Standard170 pagesEnglish languagesale 10% offe-Library read for1 day
1.1 Scope of EN 12309
Appliances covered by this European Standard include one or a combination of the following:
- gas-fired sorption chiller;
- gas-fired sorption chiller/heater;
- gas-fired sorption heat pump.
This European Standard applies to appliances designed to be used for space heating or cooling or refrigeration with or without heat recovery.
This European Standard applies to appliances having flue gas systems of type B and C (according to CEN/TR 1749) and to appliances designed for outdoor installations. EN 12309 does not apply to air conditioners, it only applies to appliances having:
- integral burners under the control of fully automatic burner control systems,
- closed system refrigerant circuits in which the refrigerant does not come into direct contact with the water or air to be cooled or heated,
- mechanical means to assist transportation of the combustion air and/or the flue gas.
The above appliances can have one or more primary or secondary functions (i.e. heat recovery - see definitions in prEN 12309 1:2012).
In the case of packaged units (consisting of several parts), this standard applies only to those designed and supplied as a complete package.
The appliances having their condenser cooled by air and by the evaporation of external additional water are not covered by EN 12309.
Installations used for heating and/or cooling of industrial processes are not within the scope of EN 12309.
All the symbols given in this text should be used regardless of the language used.
1.2 Scope of this Part 7 of EN 12309
This part of EN 12309 deals particularly with the specific provisions of hybrid heating appliances based on gas-driven sorption heat pumps as defined in Part 1.
The heating appliances covered by this European Standard are of a hybrid type, an encased assembly or assemblies combining a direct or indirect-fired sorption heat pump for base load and a peak load condensing boiler with only one flue system, electrical supply cable and human machine interface to the end user. The direct- or indirect-fired sorption heat pump integrated in the hybrid appliances in this European Standard could be intermittent or continuously operating ab or adsorption heat pump.
The control system of hybrid heating appliances decides on the transition between the heat pump operation mode to/from the mixed operation mode (heating by both sorption heat pump as well as the peak boiler) and the direct heating mode (only peak boiler) depending on the heating fluid inlet or return temperature, temperature of brine entering the indoor heat exchanger (evaporator) of the heat pump, the required outlet or supply temperature dependent on the outdoor temperature as well as the target value of the indoor or room temperature. Upon transition from the heat pump operation mode to the mixed operation mode, the control system decides also on the degree of mixing based on the above mentioned parameters.
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the test methods and requirements for the construction and operating characteristics relating to the safety, rational use of energy and marking, of commercial gas heated boiling pans.
This European Standard only covers type testing.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the safety, construction and performance requirements for combustion product sensing devices intended to be used in combustion control systems, hereinafter referred to as CPSD.
This European Standard applies to sensing devices for the measurement of combustion products from burners and appliances for domestic, commercial and industrial use burning:
- gaseous fuels according to EN 437; or
- liquid fuels having a viscosity at the burner inlet of 1,6 mm2/s (cSt) up to 6 mm2/s (cSt) at 20 °C, higher boiling petroleum based first raffinates (viscosity greater than 6 mm2/s), that require preheating for proper atomisation.
This European Standard applies to all types of stationary sensing devices measuring flue gas components O2, CO, CO2, H2, CxHy, NOX, SO2 or for a combination of them (multiple gasses).
This European Standard applies also to sensing devices for extractive systems.
This European Standard does not cover sensor requirements for combustible gas, combustible gas mixture and oil quality.
- Standard50 pagesEnglish languagesale 10% offe-Library read for1 day
1.1 Scope of EN 12309
Appliances covered by this European Standard include one or a combination of the following:
- gas-fired sorption chiller;
- gas-fired sorption chiller/heater;
- gas-fired sorption heat pump.
This European Standard applies to appliances designed to be used for space heating or cooling or refrigeration with or without heat recovery.
This European Standard applies to appliances having flue gas systems of type B and C (according to CEN/TR 1749) and to appliances designed for outdoor installations. EN 12309 does not apply to air conditioners, it only applies to appliances having:
- integral burners under the control of fully automatic burner control systems,
- closed system refrigerant circuits in which the refrigerant does not come into direct contact with the water or air to be cooled or heated,
- mechanical means to assist transportation of the combustion air and/or the flue gas.
The above appliances can have one or more primary or secondary functions (i.e. heat recovery - see definitions in prEN 12309 1:2012).
In the case of packaged units (consisting of several parts), this standard applies only to those designed and supplied as a complete package.
The appliances having their condenser cooled by air and by the evaporation of external additional water are not covered by EN 12309.
Installations used for heating and/or cooling of industrial processes are not within the scope of EN 12309.
All the symbols given in this text should be used regardless of the language used.
1.2 Scope of this Part 7 of EN 12309
This part of EN 12309 deals particularly with the specific provisions of hybrid heating appliances based on gas-driven sorption heat pumps as defined in Part 1.
The heating appliances covered by this European Standard are of a hybrid type, an encased assembly or assemblies combining a direct or indirect-fired sorption heat pump for base load and a peak load condensing boiler with only one flue system, electrical supply cable and human machine interface to the end user. The direct- or indirect-fired sorption heat pump integrated in the hybrid appliances in this European Standard could be intermittent or continuously operating ab or adsorption heat pump.
The control system of hybrid heating appliances decides on the transition between the heat pump operation mode to/from the mixed operation mode (heating by both sorption heat pump as well as the peak boiler) and the direct heating mode (only peak boiler) depending on the heating fluid inlet or return temperature, temperature of brine entering the indoor heat exchanger (evaporator) of the heat pump, the required outlet or supply temperature dependent on the outdoor temperature as well as the target value of the indoor or room temperature. Upon transition from the heat pump operation mode to the mixed operation mode, the control system decides also on the degree of mixing based on the above mentioned parameters.
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the safety, construction and performance requirements for combustion product sensing devices intended to be used in combustion control systems, hereinafter referred to as CPSD.
This European Standard applies to sensing devices for the measurement of combustion products from burners and appliances for domestic, commercial and industrial use burning:
- gaseous fuels according to EN 437; or
- liquid fuels having a viscosity at the burner inlet of 1,6 mm2/s (cSt) up to 6 mm2/s (cSt) at 20 °C, higher boiling petroleum based first raffinates (viscosity greater than 6 mm2/s), that require preheating for proper atomisation.
This European Standard applies to all types of stationary sensing devices measuring flue gas components O2, CO, CO2, H2, CxHy, NOX, SO2 or for a combination of them (multiple gasses).
This European Standard applies also to sensing devices for extractive systems.
This European Standard does not cover sensor requirements for combustible gas, combustible gas mixture and oil quality.
- Standard50 pagesEnglish languagesale 10% offe-Library read for1 day
Addition:
This European Standard specifies requirements for the construction and operating characteristics relating to the safety and marking of salamanders and rotisseries.
It also states test methods to check those characteristics.
This European Standard does not cover rational use of energy.
- Standard9 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and test methods for the construction, safety, marking and rational use of energy of open fronted gas-fired independent space heaters with and without a fan to assist with the transportation of flue gases, hereafter referred to as appliances. Although the fan may be mounted outdoors, this standard only covers appliances where the body of the appliance is indoors.
This standard applies to types B11AS, B11BS, B14AS, and B14BS (commonly referred to in this standard as type B1 appliances) open fronted gas-fired independent space heating appliances:
- that incorporate an atmospheric burner;
- that are connected directly to an open flue (see Figure 1), or to a device to evacuate the products of combustion (open-flued appliances);
- that have a nominal heat input not exceeding 20 kW (based on the net calorific value);
- that are delivered with the gas-carrying components, burner(s), combustion chamber and heat exchanger fully assembled.
It does not apply to:
- closed-fronted appliances;
- decorative fuel effect appliances as specified in EN 509;
- catalytic combustion appliances;
- ducted-air appliances;
- appliances installed by means of a closure plate (see 3.3.3.3).
- Standard105 pagesEnglish languagesale 10% offe-Library read for1 day
Addition:
This European Standard specifies requirements for the construction and operating characteristics relating to the safety and marking of salamanders and rotisseries.
It also states test methods to check those characteristics.
This European Standard does not cover rational use of energy.
- Standard9 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard defines the constructional and operational characteristics, the safety requirements, test methods and the marking of regulators and automatic change-over devices having a maximum regulated pressure of 4 bar, with a maximum capacity of 150 kg/h, for use with butane, propane and their mixtures in the vapour phase.
This European Standard also applies to the safety devices which are included within regulating devices covered by this standard. The characteristics of these safety devices are given in Annexes A and B.
This European Standard also includes the requirements for:
- adaptors for connecting to self closing valves;
- auxiliary safety devices.
For the purpose of this European Standard:
- regulators and automatic change-over devices are referred to as "regulating devices";
- regulators, automatic change-over devices and adaptors are referred to as "devices".
The requirements apply to devices used in locations where the temperature likely to be reached during use is between -20 °C and +50 °C. Additional requirements for devices to be used at temperatures below –20 °C are given in Annex C.
Additional requirements for regulating devices intended to be used in caravans, motor caravans and freshwater boats are given in Annex D.
Additional requirements for regulating devices intended to be used in seawater boats are given in Annex M.
For specific use in caravans motor caravans and boats (freshwater and seawater), the automatic change over device function may also be carried out by an assembly of regulators, forming an "automatic change over device system" as defined in 3.1.9.
For installation rules of devices and their possible associated safety devices, reference should be made to national regulations in force in the member countries.
All connections and the countries in which they are used are given in Annexes G and H.
This European Standard defines only specific connections which are not defined in other standards (e.g. EN 15202 for cylinder valve connections).
- Standard138 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and test methods for the construction, safety, marking and rational use of energy of open fronted gas-fired independent space heaters with and without a fan to assist with the transportation of flue gases, hereafter referred to as appliances. Although the fan may be mounted outdoors, this standard only covers appliances where the body of the appliance is indoors.
This standard applies to types B11AS, B11BS, B14AS, and B14BS (commonly referred to in this standard as type B1 appliances) open fronted gas-fired independent space heating appliances:
- that incorporate an atmospheric burner;
- that are connected directly to an open flue (see Figure 1), or to a device to evacuate the products of combustion (open-flued appliances);
- that have a nominal heat input not exceeding 20 kW (based on the net calorific value);
- that are delivered with the gas-carrying components, burner(s), combustion chamber and heat exchanger fully assembled.
It does not apply to:
- closed-fronted appliances;
- decorative fuel effect appliances as specified in EN 509;
- catalytic combustion appliances;
- ducted-air appliances;
- appliances installed by means of a closure plate (see 3.3.3.3).
- Standard105 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the constructional and performance characteristics, safety specifications, relevant test methods and marking of barbecues burning liquefied petroleum gas, referred to in the body of the text as "appliances".
This European Standard covers barbecues as defined in 3.6 and contact grills as defined in 3.8, used outdoors and operating with the gases indicated in 4.1 according to the categories indicated in 4.2. They are fitted with at least one cooking device.
This European Standard applies to these appliances and their functional sections whether or not the latter are independent or incorporated into an assembly.
This European Standard also applies to appliances designed to be built-in.
This European Standard only applies to type testing.
Appliances supplied with third family gas at pressures greater those defined in 4.2 are outside the field of application of this European Standard.
During the consideration of this text, it was apparent that the concept of thermal efficiency with regard to appliances such as barbecues was not appropriate.
This is because:
- during cooking, there is an additional transfer of heat due to the meat juices falling onto the refractories;
- there is no relation between the item to be cooked and the useful area;
- the barbecue is an outdoor appliance in which the action of the wind is important in relation to efficiency.
In consequence there is no specific requirement covering thermal efficiency for this type of appliance.
This European Standard does not state all applicable requirements for integral equipments of other nature (for example burners covered by EN 484).
- Standard63 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the construction and performance characteristics as well as the requirements and methods of test for the safety and marking of domestic cooking appliances, capable of using the combustible gases defined in EN 30-1-1:2008+A2:2010, that have one or more burners with an automatic burner control system, referred to in the text as "appliances".
This European Standard includes specific requirements and methods of test that are applicable to burners having an automatic burner control system, whether or not the appliance is equipped with a fan for the supply of combustion air to, and/or the evacuation of the products of combustion from the burner concerned. These specific requirements and methods of test are only applicable when the burner has an automatic burner control system and do not apply to burners having automatic ignition that fall within the scope of
EN 30-1-1:2008+A2:2010.
This European Standard is intended to be used in conjunction with EN 30-1-1:2008+A2:2010 and, where appropriate, other parts of EN 30-1 covering appliances having:
- forced-convection ovens and/or grills;
- a glass ceramic hotplate.
It does not cover all of the safety requirements and methods of test that are specific to forced-convection ovens and/or grills and glass ceramic hotplates.
Unless specifically excluded hereafter, this standard applies to these appliances or their component parts, whether or not the component parts are independent or incorporated into a single appliance, even if the other heating components of the appliance use electrical energy (e.g. combined gas-electric cookers).
This European Standard includes requirements covering the electrical safety of equipment incorporated in the appliance that is associated with the use of gas. It does not include requirements covering the electrical safety of electrically heated component parts of their associated equipment ).
This European Standard does not apply to:
- outdoor appliances;
- appliances connected to a combustion products evacuation duct;
- appliances having a pyrolytic gas oven;
- appliances having automatic burner control systems that:
- have a second safety time (see EN 298:2003), or
- control one or more burners that incorporate a separate ignition burner;
- appliances having an uncovered burner or a non-enclosed covered burner (see 3.1.1) that utilises a fan for the supply of its combustion air;
- appliances having enclosed covered burners that are not equipped with an automatic burner control system;
- appliances having one or more burners that are capable of remote operation (type1), unless the burner(s) concerned are:
- oven burners equipped with an automatic burner control system, or
- oven burners of time-controlled ovens that are designed for a delayed start without the user being present;
- appliances having one or more burners that are capable of remote operation (type 2), unless the burner(s) concerned are:
- oven, grill or hotplate burners equipped with automatic burner control systems, or
- oven burners of time-controlled ovens that are designed for a delayed start without the user being present;
- appliances supplied at pressures greater than those defined in 7.1.3;
- appliances equipped with air-gas ratio controls;
- appliances incorporating one or more hotplate or grill burners that enable the user to program the delayed start of a cooking cycle.
This European Standard does not cover the requirements relating to automatic on-off cycling multi-ring hotplate burners for which specific requirements are under consideration.
This European Standard does not cover the requirements relating to third family gas cylinders, their regulators and their connection.
This European Standard only covers type testing.
- Standard102 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the constructional and performance characteristics, safety specifications, relevant test methods and marking of barbecues burning liquefied petroleum gas, referred to in the body of the text as "appliances".
This European Standard covers barbecues as defined in 3.6 and contact grills as defined in 3.8, used outdoors and operating with the gases indicated in 4.1 according to the categories indicated in 4.2. They are fitted with at least one cooking device.
This European Standard applies to these appliances and their functional sections whether or not the latter are independent or incorporated into an assembly.
This European Standard also applies to appliances designed to be built-in.
This European Standard only applies to type testing.
Appliances supplied with third family gas at pressures greater those defined in 4.2 are outside the field of application of this European Standard.
During the consideration of this text, it was apparent that the concept of thermal efficiency with regard to appliances such as barbecues was not appropriate.
This is because:
- during cooking, there is an additional transfer of heat due to the meat juices falling onto the refractories;
- there is no relation between the item to be cooked and the useful area;
- the barbecue is an outdoor appliance in which the action of the wind is important in relation to efficiency.
In consequence there is no specific requirement covering thermal efficiency for this type of appliance.
This European Standard does not state all applicable requirements for integral equipments of other nature (for example burners covered by EN 484).
- Standard63 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the construction and performance characteristics as well as the requirements and methods of test for the safety and marking of domestic cooking appliances, capable of using the combustible gases defined in EN 30-1-1:2008+A2:2010, that have one or more burners with an automatic burner control system, referred to in the text as "appliances".
This European Standard includes specific requirements and methods of test that are applicable to burners having an automatic burner control system, whether or not the appliance is equipped with a fan for the supply of combustion air to, and/or the evacuation of the products of combustion from the burner concerned. These specific requirements and methods of test are only applicable when the burner has an automatic burner control system and do not apply to burners having automatic ignition that fall within the scope of
EN 30-1-1:2008+A2:2010.
This European Standard is intended to be used in conjunction with EN 30-1-1:2008+A2:2010 and, where appropriate, other parts of EN 30-1 covering appliances having:
- forced-convection ovens and/or grills;
- a glass ceramic hotplate.
It does not cover all of the safety requirements and methods of test that are specific to forced-convection ovens and/or grills and glass ceramic hotplates.
Unless specifically excluded hereafter, this standard applies to these appliances or their component parts, whether or not the component parts are independent or incorporated into a single appliance, even if the other heating components of the appliance use electrical energy (e.g. combined gas-electric cookers).
This European Standard includes requirements covering the electrical safety of equipment incorporated in the appliance that is associated with the use of gas. It does not include requirements covering the electrical safety of electrically heated component parts of their associated equipment ).
This European Standard does not apply to:
- outdoor appliances;
- appliances connected to a combustion products evacuation duct;
- appliances having a pyrolytic gas oven;
- appliances having automatic burner control systems that:
- have a second safety time (see EN 298:2003), or
- control one or more burners that incorporate a separate ignition burner;
- appliances having an uncovered burner or a non-enclosed covered burner (see 3.1.1) that utilises a fan for the supply of its combustion air;
- appliances having enclosed covered burners that are not equipped with an automatic burner control system;
- appliances having one or more burners that are capable of remote operation (type1), unless the burner(s) concerned are:
- oven burners equipped with an automatic burner control system, or
- oven burners of time-controlled ovens that are designed for a delayed start without the user being present;
- appliances having one or more burners that are capable of remote operation (type 2), unless the burner(s) concerned are:
- oven, grill or hotplate burners equipped with automatic burner control systems, or
- oven burners of time-controlled ovens that are designed for a delayed start without the user being present;
- appliances supplied at pressures greater than those defined in 7.1.3;
- appliances equipped with air-gas ratio controls;
- appliances incorporating one or more hotplate or grill burners that enable the user to program the delayed start of a cooking cycle.
This European Standard does not cover the requirements relating to automatic on-off cycling multi-ring hotplate burners for which specific requirements are under consideration.
This European Standard does not cover the requirements relating to third family gas cylinders, their regulators and their connection.
This European Standard only covers type testing.
- Standard102 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and test methods for the construction, safety, and marking of domestic direct gas-fired tumble dryers, of types B22D and B23D, of nominal heat input not exceeding 6 kW, hereafter referred to as "appliances".
This European Standard does not apply to:
a) catalytic combustion appliances;
b) appliances designed exclusively for industrial purposes;
c) appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere;
d) appliances of the condensing type wherein the heated air and products of combustion used for the drying process are dehumidified by cooling with water or air;
e) appliances intended to be used in vehicles or on board ships or aircraft.
This European Standard covers type testing only.
- Standard97 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and test methods for rational use of energy, including measurement of both gas and electrical energy consumption, of domestic direct gas-fired tumble dryers, of types B22D and B23D, of nominal heat input not exceeding 6 kW, hereafter referred to as "appliances".
This European Standard does not apply to:
a) catalytic combustion appliances;
b) appliances designed exclusively for industrial purposes;
c) appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere;
d) appliances of the condensing type wherein the heated air and products of combustion used for the drying process are dehumidified by cooling with water or air;
e) appliances intended to be used in vehicles or on board ships or aircraft.
This European Standard covers type testing only.
- Standard6 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and test methods for rational use of energy, including measurement of both gas and electrical energy consumption, of domestic direct gas-fired tumble dryers, of types B22D and B23D, of nominal heat input not exceeding 6 kW, hereafter referred to as "appliances".
This European Standard does not apply to:
a) catalytic combustion appliances;
b) appliances designed exclusively for industrial purposes;
c) appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere;
d) appliances of the condensing type wherein the heated air and products of combustion used for the drying process are dehumidified by cooling with water or air;
e) appliances intended to be used in vehicles or on board ships or aircraft.
This European Standard covers type testing only.
- Standard6 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and test methods for the construction, safety, and marking of domestic direct gas-fired tumble dryers, of types B22D and B23D, of nominal heat input not exceeding 6 kW, hereafter referred to as "appliances".
This European Standard does not apply to:
a) catalytic combustion appliances;
b) appliances designed exclusively for industrial purposes;
c) appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere;
d) appliances of the condensing type wherein the heated air and products of combustion used for the drying process are dehumidified by cooling with water or air;
e) appliances intended to be used in vehicles or on board ships or aircraft.
This European Standard covers type testing only.
- Standard97 pagesEnglish languagesale 10% offe-Library read for1 day
This European standard specifies the characteristics of safety, construction, performance and efficiency, the test methods and marking, of room sealed space heating equipment of type C (see CEN/TR 1749) with combustion air intake and outlet for the products of combustion in the wall, roof or floor, combined or not. These are referred to in the body of the text as "heaters", burning LPG, for vehicles and boats.
This European standard only covers room sealed heaters also including those which have a combustion air fan, an integral hot air fan or both, only for vehicles and boats which are used for residential, recreational and commercial purposes.
This European standard applies to heaters which are installed either outside or inside the habitable volume, but which have a combustion circuit sealed from the vehicle's interior, and nominal heat input which does not exceed 10 kW (Hs) operated at supply pressure of 30 mbar, 28 mbar, 37 mbar and 50 mbar, using, where appropriate, 12 V or 24 V DC electrical supply.
Room sealed LPG space heating appliances for vehicles and boats are using very often warm air as a heat transfer medium. Annex B specifies additional requirements for appliances using water as a heat transfer medium.
For private cars and vehicles or boats used for the transport of dangerous goods or for commercial personnel transport additional requirements may be necessary.
This European standard does not cover requirements for storage water heaters (boilers) (see EN 15033). For appliances producing additional sanitary hot water (combi-boilers), see relevant clauses of EN 15033.
NOTE If a LPG operated heater is installed in a motorized vehicle being subject to European road traffic legislation, the directives of the Council for the approximation of the laws, regulations and administrative provisions of the member states relating to the heating of the interior of motor vehicles should be applied.
These heaters are also suitable for caravan holiday homes.
- Standard58 pagesEnglish languagesale 10% offe-Library read for1 day
This European standard specifies the characteristics of safety, construction, performance and efficiency, the test methods and marking, of room sealed space heating equipment of type C (see CEN/TR 1749) with combustion air intake and outlet for the products of combustion in the wall, roof or floor, combined or not. These are referred to in the body of the text as "heaters", burning LPG, for vehicles and boats.
This European standard only covers room sealed heaters also including those which have a combustion air fan, an integral hot air fan or both, only for vehicles and boats which are used for residential, recreational and commercial purposes.
This European standard applies to heaters which are installed either outside or inside the habitable volume, but which have a combustion circuit sealed from the vehicle's interior, and nominal heat input which does not exceed 10 kW (Hs) operated at supply pressure of 30 mbar, 28 mbar, 37 mbar and 50 mbar, using, where appropriate, 12 V or 24 V DC electrical supply.
Room sealed LPG space heating appliances for vehicles and boats are using very often warm air as a heat transfer medium. Annex B specifies additional requirements for appliances using water as a heat transfer medium.
For private cars and vehicles or boats used for the transport of dangerous goods or for commercial personnel transport additional requirements may be necessary.
This European standard does not cover requirements for storage water heaters (boilers) (see EN 15033). For appliances producing additional sanitary hot water (combi-boilers), see relevant clauses of EN 15033.
NOTE If a LPG operated heater is installed in a motorized vehicle being subject to European road traffic legislation, the directives of the Council for the approximation of the laws, regulations and administrative provisions of the member states relating to the heating of the interior of motor vehicles should be applied.
These heaters are also suitable for caravan holiday homes.
- Standard58 pagesEnglish languagesale 10% offe-Library read for1 day
Addition:
This European Standard specifies the test methods and requirements for the construction and operating characteristics relating to the safety, rational use of energy and marking of commercial gas heated pasta cookers.
- Standard9 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements for the construction and operating characteristics relating to the safety and rational use of energy for solid tops, warming plates and griddles, the burners of which are enclosed and the flue gases of which are evacuated by a specific way.
This European Standard only covers type testing.
- Standard7 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements for the construction and operating characteristics relating to safety and rational use of energy of brat pans and paella cookers so called after "brat pan".
It also states the test methods suitable to check those characteristics.
This European Standard only cover type testing.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the test methods and requirements for the construction and operating characteristics relating to the safety, rational use of energy and marking, of Commercial Gas Heated Water Boiling and Heating Appliances for Beverage Making.
This European Standard only covers type testing.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard defines the specifications and test methods for the construction, safety, rational use of energy and fitness for purpose, environment, classification and marking of room sealed storage water heaters for the production of sanitary hot water using LPG for: vehicles as defined in article 1 of Directive 70/156/EEC (see 3.12); caravan holiday homes; agricultural, forestry and mobile machinery, and boats; hereafter called "appliance". This standard applies to appliances: type C1, C3 and C5 (room sealed, see CEN/TR 1749) with combustion air intake and outlet for the products of combustion (combined or not) in the wall or roof; fitted with atmospheric burners; appliances fitted with or without a fan on the combustion circuit; using LPG at the pressure I3BP(30) indicated in EN 437, (for caravan holiday homes and boats see Annex A); of nominal heat input not exceeding 7 kW (Hi); appliances whether connected to the water mains pressure or on board water supply; appliances using, where appropriate, 12 V or 24 V DC electrical supply (or appliances with an additional 230 V heating element). This standard does not contain all the necessary requirements for: appliances which fulfil a dual purpose role of space heating and heating water for sanitary hot water use. This standard covers type testing only.
- Corrigendum2 pagesEnglish languagesale 10% offe-Library read for1 day