TC 69 - Electrical power/energy transfer systems for electrically propelled road vehicles and industrial trucks
To prepare publications on electrical power/energy transfer systems for electrically propelled road vehicles and industrial trucks (hereafter EV) drawing current from a rechargeable energy storage system (RESS). Possibilities to transfer power/energy include conductive power/energy transfer, wireless power/energy transfer and battery swap. The different publications can cover, but are not limited to: general requirements (e.g. safety, EMC, construction, testing); functional requirements (e.g. charging modes); communication between the EV and the EV supply equipment; electrical power/energy transfer between EV and supply network (G2V and V2G); management of the corresponding infrastructures in view of offering the associated value added services. EV include but are not limited to passenger cars and buses, two and three-wheel and light four-wheel vehicles, trucks and goods vehicles, trailers and special and industrial trucks. Trains, trams and trolleybuses are out of scope of TC69.
Systèmes de transfert de puissance ou d'énergie électrique destinés aux véhicules routiers électriques ou chariots industriels de manutention
Préparer des publications sur les systèmes de transfert d'énergie électrique pour les véhicules routiers et les camions industriels à propulsion électrique (ci-après VE) tirant du courant d'un système de stockage d'énergie rechargeable (RESS). Les possibilités de transfert de puissance/énergie incluent le transfert de puissance/énergie par conduction, le transfert de puissance/énergie sans fil et l’échange de batterie. Les différentes publications peuvent couvrir, sans toutefois s'y limiter : • Les exigences générales (par exemple sécurité, CEM, construction, tests) ; • Les exigences fonctionnelles (par exemple modes de recharge) ; • La communication entre le VE et l'équipement d'alimentation du VE ; • Le transfert d'énergie électrique entre le VE et le réseau d'alimentation (G2V et V2G) ; • La gestion des infrastructures correspondantes en vue d'offrir les services à valeur ajoutée associés. Les véhicules électriques comprennent, mais sans s'y limiter, les voitures de tourisme et les autobus, les véhicules à deux ou quatre roues, les camions et les véhicules utilitaires, les remorques et les camions spéciaux et industriels. Les systèmes de transfert de puissance ou d’énergie électrique pour trains, tramways et trolleybus ne relèvent pas du champ d'application du TC 69.
General Information
IEC 61851-24:2023, together with IEC 61851-23, applies to digital communication between a DC EV supply equipment and an electric road vehicle (EV) for control of conductive DC power transfer, with a rated supply voltage up to 1 000 V AC or up to 1 500 V DC and a rated output voltage up to 1 500 V DC.
This document also applies to digital communication between the DC EV charging/discharging station and the EV for system A, as specified in Annex A.
The EV charging mode is mode 4, according to IEC 61851-23.
Annex A, Annex B, and Annex C give descriptions of digital communications for control of DC charging specific to DC EV charging systems A, B and C as defined in IEC 61851-23.
This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- Annex A and Annex B have been updated in line with IEC 61851-23:2023 and relevant standards.
- Standard105 pagesEnglish and French languagesale 15% off
IEC 61851-23:2023 applies to the EV supply equipment to provide energy transfer between the supply network and electric vehicles (EVs), with a rated maximum voltage at side A of up to 1 000 V AC or up to 1 500 V DC and a rated maximum voltage at side B up to 1 500 V DC.
This document specifies the EV supply equipment of system A, system B and system C as defined in Annex AA, Annex BB and Annex CC. Other systems are under consideration.
This document provides the requirements for bidirectional power transfer (BPT) EV supply equipment for system A, with a rated maximum voltage at side A up to 1 000 V AC or 1 500 V DC. The requirements for reverse power transfer (RPT) and BPT for system B and system C are under consideration and are not specified in this document.
This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) the structure has been rearranged according to IEC 61851-1:2017;
b) electrical safety requirements in Clause 8 and Clause 12 have been revised based on the requirements in IEC 62477-1 and inspired by the hazard based safety approach of IEC 62368-1;
c) test methods for checking conformity to the stated requirements have been mostly added; general provisions for compliance tests have been specified in Clause 102;
d) specific requirements and/or information for the following functions have been added: energy transfer with thermal management system (101.2), bi-directional power transfer control (Annex DD), multi- side B separated EV supply equipment (Annex FF), and communication and energy transfer process (Annex GG);
e) Annex AA (system A), Annex BB (system B) and Annex CC (system C) have been updated including additions in conjunction with b) and c). This document has been limited to be applicable to system A, system B and system C;
f) the former Annex DD and Annex EE have been deleted. A new Annex EE, with the requirements for the artificial test load, has been added.
g) a new informative annex for the touch current and the touch impulse current (Annex HH) has been added
- Standard383 pagesEnglish languagesale 15% off
- Standard6 pagesEnglish and French languagesale 15% off
IEC TS 61851-3-5:2023 This part of IEC 61851, which is a Technical Specification, applies to CANopen communication for the conductive transfer of electric power between the supply network and an electric road vehicle or a removable RESS or traction-battery of an electric road vehicle.
This document provides specifications with regard to the pre-defined communication parameters and general application objects.
- Technical specification173 pagesEnglish languagesale 15% off
IEC TS 61851-3-1:2023 This part of IEC 61851, which is a Technical Specification, applies to the equipment, including stationary equipment for
- the conductive transfer of electric power between the supply network and
- an electric road vehicle, or
- a removable rechargeable energy storage system (RESS), or
- an on-board RESS of an electric road vehicle,
- when the equipment is connected to the supply network having a supply voltage up to 480 V AC or up to 400 V DC and a rated output voltage up to 120 V DC, and
- where the protection against electric shock relies on double or reinforced insulation, and with double or reinforced insulation between all AC and DC inputs and outputs.
- Technical specification51 pagesEnglish languagesale 15% off
IEC TS 61851-3-4:2023 This part of IEC 61851, which is a Technical Specification, applies to CANopen communication for the conductive transfer of electric power between the supply network and an electric road vehicle or a removable rechargeable energy storage system (RESS) or on-board rechargeable energy storage systems (RESS) of an electric road vehicle.
The energy management system (EMS) for control of power transfer between battery systems and voltage converter units (VCU) provides the communication for all devices that can take part in energy management control.
The basic application profile for energy management systems (EMS) consists of IEC TS 61851-3-4, IEC TS 61851-3-5, IEC TS 61851-3-6, IEC TS 61851-3-7.
- Technical specification102 pagesEnglish languagesale 15% off
IEC TS 61851-3-6:2023 This part of IEC 61851, which is a Technical Specification, applies to CANopen communication for the conductive transfer of electric power between the supply network and an electric road vehicle or a removable RESS or traction-battery of an electric road vehicle.
This document provides application objects provided by the AC/DC VCU or DC/DC VCU.
- Technical specification162 pagesEnglish languagesale 15% off
IEC TS 61851-3-7:2023 This part of IEC 61851, which is a Technical Specification, applies to CANopen communication for the conductive transfer of electric power between the supply network and an electric road vehicle or a removable RESS or traction-battery of an electric road vehicle.
This document specifies application objects provided by the battery system.
- Technical specification106 pagesEnglish languagesale 15% off
IEC TS 61851-3-2:2023 This part of IEC 61851, which is a Technical Specification, applies to the portable and mobile DRI EV supply equipment where the protection against electric shocks relies on double or reinforced insulation, and with double or reinforced insulation between all AC and DC inputs and outputs with a rated input voltage being not more than 250 V AC and output voltages not more than 120 V DC.
- Technical specification35 pagesEnglish languagesale 15% off
IEC 61980-2:2023 addresses communication and activities of magnetic field wireless power transfer (MF-WPT) systems.
The requirements in this document are intended to be applied for MF-WPT systems according to IEC 61980-3 and ISO 19363.
The aspects covered in this document include operational and functional characteristics of the MF-WPT communication system and related activities, and operational and functional characteristics of the positioning system.
The following aspects are under consideration for future documents:
- requirements for two- and three-wheel vehicles;
- requirements for MF-WPT systems supplying power to EVs in motion;
- requirements for bidirectional power transfer.
NOTE Any internal communication at supply device or EV device is not in the scope of this document
- Standard195 pagesEnglish and French languagesale 15% off
IEC PAS 61851-1-1:2023 applies to a new type of AC EV supply equipment for charging electric road vehicles, with a rated supply voltage up to 1 000 V AC and a rated output voltage up to 1 000 V AC.
This document provides specific requirements for AC charging system using type 4 vehicle coupler.
Type 4 vehicle coupler is under consideration by SC23H.
Vehicle inlet and vehicle connector of type 4 are intended to be used for charging in modes 2 and 3, case C.
This document is to be read in conjunction with IEC 61851-1:2017.
- Technical specification13 pagesEnglish languagesale 15% off
ISO 15118-9:2022 This document specifies conformance tests in the form of an abstract test suite (ATS) for a system under test (SUT) implementing an electric-vehicle or supply-equipment communication controller (EVCC or SECC) with support for WLAN-based high-level communication (HLC) according to ISO 15118‑8 and against the background of ISO 15118-1. These conformance tests specify the testing of capabilities and behaviours of an SUT, as well as checking what is observed against the conformance requirements specified in ISO 15118‑8 and against what the implementer states the SUT implementation's capabilities are.
The capability tests within the ATS check that the observable capabilities of the SUT are in accordance with the static conformance requirements defined in ISO 15118‑8. The behaviour tests of the ATS examine an implementation as thoroughly as practical over the full range of dynamic conformance requirements defined in ISO 15118‑8 and within the capabilities of the SUT (see NOTE below).
A test architecture is described in correspondence to the ATS. The abstract test cases in this document are described leveraging this test architecture and are specified in descriptive tabular format for the ISO/OSI physical and data link layers (layers 1 and 2).
In terms of coverage, this document only covers normative sections and requirements in ISO 15118‑8. This document can additionally refer to specific tests for requirements on referenced standards (e.g. IEEE, or industry consortia standards, like WiFi Alliance) as long as they are relevant in terms of conformance for implementations according to ISO 15118‑8. However, it is explicitly not intended to widen the scope of this conformance specification to such external standards, if it is not technically necessary for the purpose of conformance testing for ISO 15118‑8. Furthermore, the conformance tests specified in this document do not include the assessment of performance nor robustness or reliability of an implementation. They cannot provide judgments on the physical realization of abstract service primitives, how a system is implemented, how it provides any requested service, nor the environment of the protocol implementation. Furthermore, the abstract test cases defined in this document only consider the communication protocol and the system's behaviour defined ISO 15118‑8. The power flow between the EVSE and the EV is not considered.
NOTE Practical limitations make it impossible to define an exhaustive test suite, and economic considerations can restrict testing even further. Hence, the purpose of this document is to increase the probability that different implementations are able to interwork. This is achieved by verifying them by means of a protocol test suite, thereby increasing the confidence that each implementation conforms to the protocol specification. However, the specified protocol test suite cannot guarantee conformance to the specification since it detects errors rather than their absence. Thus, conformance to a test suite alone cannot guarantee interworking. Instead, it gives confidence that an implementation has the required capabilities and that its behaviour conforms consistently in representative instances of communication.
- Standard72 pagesEnglish languagesale 15% off
IEC 61980-3:2022 applies to the off-board supply equipment for wireless power transfer via magnetic field (MF-WPT) to electric road vehicles for purposes of supplying electric energy to the RESS (rechargeable energy storage system) and/or other on-board electrical systems. The MF-WPT system operates at standard supply voltage ratings per IEC 60038 up to 1 000 V AC and up to 1 500 V DC from the supply network. The power transfer takes place while the electric vehicle (EV) is stationary.
Off-board supply equipment fulfilling the requirements in this document are intended to operate with EV devices fulfilling the requirements described in ISO 19363.
The aspects covered in this document include
– the characteristics and operating conditions,
– the required level of electrical safety,
– requirements for basic communication for safety and process matters if required by a MF WPT system,
– requirements for positioning to assure efficient and safe MF-WPT power transfer, and
– specific EMC requirements for MF-WPT systems.
The following aspects are under consideration for future documents:
– requirements for MF-WPT systems for two- and three-wheel vehicles,
– requirements for MF-WPT systems supplying power to EVs in motion,
– requirements for bidirectional power transfer,
– requirements for flush mounted primary device,
– requirements for MF-WPT systems for heavy duty vehicle, and
– requirements for MF-WPT systems with inputs greater than 11,1 kVA.
This document does not apply to
– safety aspects related to maintenance, and
– trolley buses, rail vehicles and vehicles designed primarily for use off-road.
IEC 61980-3:2022 is to be used in conjunction with IEC 61980-1:2020.
- Standard239 pagesEnglish and French languagesale 15% off
IEC 63119-2:2022 specifies roaming use cases of information exchange between EV charging service providers (CSP), charging station operators (CSOs) and clearing house platforms through roaming endpoints. The elementary use cases defined in this document are designed to support the user to have access to the EV supply equipment which does not belong to the home-CSP.
IEC 63119 (all parts) is applicable to high-level communication involved in information exchange/interaction between different CSPs, as well as between a CSP and CSO with or without clearing house platform through the roaming endpoint.
IEC 63119 (all parts) does not specify the communication either between charging station (CS) and charging station operator (CSO) or between EV and CS.
- Standard120 pagesEnglish and French languagesale 15% off
IEC 63110-1:2022, as a basis for the other parts of IEC 63110, covers the definitions, use cases and architecture for the management of electric vehicle charging and discharging infrastructures.
It addresses the general requirements for the establishment of an e-mobility eco-system, therefore covering the communication flows between different e-mobility actors as well as data flows with the electric power system.
This document covers the following features:
– management of energy transfer (e.g., charging session), reporting, including information exchanges related to the required energy, grid usage, contractual data, and metering data;
– asset management of EVSE, including controlling, monitoring, maintaining, provisioning, firmware update and configuration (profiles) of EVSE;
– authentication/authorization/payment of charging and discharging sessions, including roaming, pricing, and metering information;
– the provision of other e-mobility services;
– cybersecurity.
- Standard314 pagesEnglish and French languagesale 15% off
ISO 15118-20:2022 This document specifies the communication between the electric vehicle (EV), including battery electric vehicle (BEV) and plug-in hybrid electric vehicle (PHEV), and the electric vehicle supply equipment (EVSE). The application layer messages defined in this document are designed to support the electricity power transfer between an EV and an EVSE.
This document defines the communication messages and sequence requirements for bidirectional power transfer.
This document furthermore defines requirements of wireless communication for both conductive charging and wireless charging as well as communication requirements for automatic connection device and information services about charging and control status.
The purpose of this document is to detail the communication between an electric vehicle communication controller (EVCC) and a supply equipment communication controller (SECC). Aspects are specified to detect a vehicle in a communication network and enable an Internet Protocol (IP) based communication between the EVCC and the SECC.
- Standard561 pagesEnglish languagesale 15% off
- Standard606 pagesFrench languagesale 15% off
IEC PAS 62840-3:2021 applies to battery swap systems for removable RESS of electric road vehicle when connected to the supply network, with a rated supply voltage up to 480 V AC or up to 400 V DC, for battery systems with a rated voltage up to 120 V DC.
This document applies to battery swap systems for removable RESS/EV where the removable RESS/EV is stored for the purpose of transfer power between the battery swap station and removable RESS/EV.
Requirements for bidirectional energy transfer DC to AC are under consideration and are not part of this document.
This document applies to:
– battery swap systems supplied from on-site storage systems (for example buffer batteries etc;
– manual, mechanically assisted and automatic systems);
– battery swap systems intended to supply removable battery systems having communication allowing to identify the battery system characteristics;
– battery swap systems intended to be installed at an altitude of up to 2 000 m.
The aspects covered in this document include:
– requirements for power transfer between the battery systems;
– additional requirements for communication;
– the connection to supply network.
Additional requirements may apply to special locations.
This document does not apply to:
– safety requirements for mechanical equipment covered by ISO 10218 (all parts);
– locking compartments systems providing AC socket-outlets for the use of manufacturer specific voltage converter units and manufacturer specific battery systems;
– safety aspects related to maintenance;
– electrical devices and components which are covered by their specific product standards;
– trolley buses, rail vehicles;
– any on-board equipment which is covered by ISO;
– EMC requirements for on-board equipment while connected to the supply, which are covered by IEC 61851-21-1.
Requirements for battery swap systems using protective measures as covered by 410 of IEC 60364-4-41:2005 other than double or reinforced insulation are under consideration.
- Technical specification39 pagesEnglish languagesale 15% off
IEC 61851-25:2020 applies to the DC EV supply equipment for charging electric road vehicles with a rated supply voltage of up to 480 V AC or up to 600 V DC, with rated output voltage not exceeding 120 V DC and output currents not exceeding 100 A DC.
This document provides the requirements for the DC EV supply equipment where the secondary circuit is protected from the primary circuit by electrical separation.
Requirements for bi-directional power flow are not covered in this document.
This document also provides the requirements for the control and the communication between DC EV supply equipment and an EV.
This document also applies to DC EV supply equipment supplied from on-site storage systems.
The aspects covered in this document include:
• characteristics and operating conditions of the DC EV supply equipment;
• specification of the connection between the DC EV supply equipment and the EV;
• requirements for electrical safety for the DC EV supply equipment.
Additional requirements can apply to equipment designed for specific environments or conditions, for example:
• DC EV supply equipment located in hazardous areas where flammable gas or vapour and/or combustible materials, fuels or other combustible, or explosive materials are present;
• DC EV supply equipment designed to be installed at an altitude of more than 2 000 m;
• DC EV supply equipment intended to be used on-board ships.
Requirements for electrical devices and components used in DC EV supply equipment are not included in this document and are covered by their specific product standards.
This document does not apply to:
• safety aspects related to maintenance;
• charging of trolley buses, rail vehicles, industrial trucks and vehicles designed primarily for use off-road;
• equipment on the EV;
• EMC requirements for equipment on the EV while connected, which are covered in IEC 61851-21-1;
• charging the RESS off-board the EV.
- Standard135 pagesEnglish and French languagesale 15% off
IEC 61980-1:2020 applies to the supply device for charging electric road vehicles using wireless methods at standard supply voltages per IEC 60038 up to 1 000 V AC and up to 1 500 V DC.
Electric road vehicles (EV) covers road vehicles, including plug-in hybrid road vehicles (PHEV) that derive all or part of their energy from on-board rechargeable energy storage systems (RESS).
This document also applies to wireless power transfer (WPT) equipment supplied from on-site storage systems (e.g. buffer batteries).
The aspects covered in this document include
• the characteristics and operating conditions of a supply device,
• the specification for required level of electrical safety of a supply device,
• communication between EV device and vehicle to enable and control WPT,
• efficiency, alignment and other activities to enable WPT, and
• specific EMC requirements for a supply device.
The following aspects are under consideration for future documents:
• requirements for MF-WPT systems supplying power to EVs in motion;
• requirements for bidirectional power transfer.
This document does not apply to:
• safety aspects related to maintenance,
• WPT system for trolley buses, rail vehicles and vehicles designed primarily for use off‑road, and
• any safety or EMC requirements for the vehicle side.
IEC 61980-1:2020 cancels and replaces the first edition published in 2015. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) the contents of IEC 61980-1:2015 have been re-organized so that this document is generally applicable to any WPT technologies;
b) technology specific requirements, mostly for MF-WPT in the main text of IEC 61980-1:2015, have been transferred to IEC 61980-2 and IEC 61980-3;
c) Annex A, Annex B and Annex C have been removed and contents of these annexes have been transferred to the relevant technology specific parts of the IEC 61980 series;
d) duplications and overlaps of the requirements within IEC 61980-1:2015 have been resolved;
e) terms and definitions which are specified in IEC 61851-1:2017 and are applicable for WPT system have been directly described in this document, with modification for some terms. The reference to IEC 61851-1 is withdrawn.
- Standard88 pagesEnglish and French languagesale 15% off
This document specifies the requirements of the physical and data link layer of a wireless High Level Communication (HLC) between Electric Vehicles (EV) and the Electric Vehicle Supply Equipment (EVSE). The wireless communication technology is used as an alternative to the wired communication technology as defined in ISO 15118‑3.
It covers the overall information exchange between all actors involved in the electrical energy exchange. ISO 15118 (all parts) are applicable for conductive charging as well as Wireless Power Transfer (WPT).
For conductive charging, only EVSEs compliant with "IEC 61851‑1 modes 3 and 4" and supporting HLC are covered by this document. For WPT, charging sites according to IEC 61980 (all parts) and vehicles according to ISO 19363 are covered by this document.
- Standard33 pagesEnglish languagesale 15% off
IEC 63119-1:2019 establishes a basis for the other parts of IEC 63119, specifying the terms and definitions, general description of the system model, classification, information exchange and security mechanisms for roaming between EV charge service providers (CSP), charging station operators (CSOs) and clearing house platforms through roaming endpoints. It provides an overview and describes the general requirements of the EV roaming service system.
IEC 63119 (all parts) is applicable to high-level communication involved in information exchange/interaction between different CSPs, as well as between a CSP and a CSO with or without a clearing house platform through the roaming endpoint.
IEC 63119 (all parts) does not specify the information exchange, either between the charging station (CS) and the charging station operator (CSO), or between the EV and the CS.
- Standard28 pagesEnglish and French languagesale 15% off
ISO 15118-1:2019 This document, as a basis for the other parts of the ISO 15118 series, specifies terms and definitions, general requirements and use cases for conductive and wireless HLC between the EVCC and the SECC.
This document is applicable to HLC involved in conductive and wireless power transfer technologies in the context of manual or automatic connection devices.
This document is also applicable to energy transfer either from EV supply equipment to charge the EV battery or from EV battery to EV supply equipment in order to supply energy to home, to loads or to the grid.
This document provides a general overview and a common understanding of aspects influencing identification, association, charge or discharge control and optimisation, payment, load levelling, cybersecurity and privacy. It offers an interoperable EV-EV supply equipment interface to all e-mobility actors beyond SECC.
The ISO 15118 series does not specify the vehicle internal communication between battery and other internal equipment (beside some dedicated message elements related to the energy transfer).
NOTE 1 Electric road vehicles specifically are vehicles in categories M (used for carriage of passengers) and N (used for carriage of goods) (compare ECE/TR ANS/WP.29/78 ev.2). This does not prevent vehicles in other categories from adopting the ISO 15118 series as well.
NOTE 2 This document is destined to orientate the message set of ISO 15118‑2 and ISO 15118‑20[1]. The absence of any particular use case in this document does not imply that it will not be put into practice, with the required messages.
NOTE 3 This document, ISO 15118‑2 and ISO 15118‑20 are designed to work independent of data transfer medium used. However, the ISO 15118 series is made for fitting the specified data link layers in the corresponding documents in this series.
[1] Under preparation. Stage at the time on publication: ISO/DIS 15118-20:2019.
- Standard117 pagesEnglish languagesale 15% off
IEC 61851-21-2:2018 defines the EMC requirements for any off-board components or equipment of such systems used to supply or charge electric vehicles with electric power by conductive power transfer (CPT), with a rated input voltage, according to IEC 60038:2009, up to 1 000 V AC or 1 500 V DC and an output voltage up to 1 000 V AC or 1 500 V DC.
This document covers off-board charging equipment for mode 1, mode 2, mode 3 and mode 4 charging as defined in IEC 61851-1:2017.
This first edition, together with IEC 61851-21-1, cancels and replaces IEC 61851-21:2001. It constitutes a technical revision.
This edition includes the following significant technical changes with respect to IEC 61851‑21:2001:
a) this document addresses now only EMC related tests instead of other electrical tests;
b) Clauses 2 and 3 have been updated;
c) the port definition, the test-setups and their corresponding limits as well as the operation modes are defined more precisely;
d) Annexes A to F have been added.
- Standard47 pagesEnglish languagesale 15% off
- Standard95 pagesEnglish and French languagesale 15% off
ISO 15118-5:2018 specifies conformance tests in the form of an Abstract Test Suite (ATS) for a System Under Test (SUT) implementing an Electric Vehicle or Supply Equipment Communication Controller (EVCC or SECC) with support for PLC-based High Level Communication (HLC) and Basic Signaling according to ISO 15118‑3. These conformance tests specify the testing of capabilities and behaviors of an SUT, as well as checking what is observed against the conformance requirements specified in ISO 15118‑3 and against what the implementer states the SUT implementation's capabilities are.
The capability tests within the ATS check that the observable capabilities of the SUT are in accordance with the static conformance requirements defined in ISO 15118‑3. The behavior tests of the ATS examine an implementation as thoroughly as is practical over the full range of dynamic conformance requirements defined in ISO 15118‑3 and within the capabilities of the SUT (see NOTE 1).
A test architecture is described in correspondence to the ATS. The conformance test cases in this part of the standard are described leveraging this test architecture and are specified in TTCN-3 Core Language for the ISO/OSI Physical and Data Link Layers (Layers 1 and 2). The conformance test cases for the ISO/OSI Network Layer (Layer 3) and above are described in ISO 15118‑4.
In terms of coverage, this document only covers normative sections and requirements in ISO 15118‑3. This document can additionally include specific tests for requirements of referenced standards (e.g. IEEE, or industry consortia standards) as long as they are relevant in terms of conformance for implementations according to ISO 15118‑3. However, it is explicitly not intended to widen the scope of this conformance specification to such external standards, if it is not technically necessary for the purpose of conformance testing for ISO 15118‑3. Furthermore, the conformance tests specified in this document do not include the assessment of performance nor robustness or reliability of an implementation. They cannot provide judgments on the physical realization of abstract service primitives, how a system is implemented, how it provides any requested service, nor the environment of the protocol implementation. Furthermore, the test cases defined in this document only consider the communication protocol and the system's behavior defined ISO 15118‑3. Power flow between the EVSE and the EV is not considered.
NOTE 1 Practical limitations make it impossible to define an exhaustive test suite, and economic considerations can restrict testing even further. Hence, the purpose of this document is to increase the probability that different implementations are able to interwork. This is achieved by verifying them by means of a protocol test suite, thereby increasing the confidence that each implementation conforms to the protocol specification. However, the specified protocol test suite cannot guarantee conformance to the specification since it detects errors rather than their absence. Thus conformance to a test suite alone cannot guarantee interworking. What it does do is give confidence that an implementation has the required capabilities and that its behavior conforms consistently in representative instances of communication.
NOTE 2 This document has some interdependencies to the conformance tests defined in ISO 15118‑4 which result from ISO/OSI cross layer dependencies in the underlying protocol specification (e.g. for sleep mode).
- Standard403 pagesEnglish languagesale 15% off
ISO 15118-4:2018 specifies conformance tests in the form of an Abstract Test Suite (ATS) for a System Under Test (SUT) implementing an EVCC or SECC according to ISO 15118-2. These conformance tests specify the testing of capabilities and behaviors of an SUT as well as checking what is observed against the conformance requirements specified in ISO 15118-2 and against what the supplier states the SUT implementation's capabilities are.
The capability tests within the ATS check that the observable capabilities of the SUT are in accordance with the static conformance requirements defined in ISO 15118-2. The behavior tests of the ATS examine an implementation as thoroughly as is practical over the full range of dynamic conformance requirements defined in ISO 15118-2 and within the capabilities of the SUT (see NOTE).
A test architecture is described in correspondence to the ATS. The conformance test cases in this document are described leveraging this test architecture and are specified in TTCN-3 Core Language for ISO/OSI Network Layer (Layer 3) and above. The conformance test cases for the Data Link Layer (Layer 2) and Physical Layer (Layer 1) are described in ISO 15118-5. Test cases with overlapping scopes are explicitly detailed.
This document does not include specific tests of other standards referenced within ISO 15118-2, e.g. IETF RFCs. Furthermore, the conformance tests specified in this document do not include the assessment of performance nor robustness or reliability of an implementation. They cannot provide judgments on the physical realization of abstract service primitives, how a system is implemented, how it provides any requested service, nor the environment of the protocol implementation. Furthermore, the test cases defined in this document only consider the communication protocol defined ISO 15118-2. Power flow between the EVSE and the EV is not considered.
NOTE 1 Practical limitations make it impossible to define an exhaustive test suite, and economic considerations can restrict testing even further. Hence, the purpose of this document is to increase the probability that different implementations are able to interwork. This is achieved by verifying them by means of a protocol test suite, thereby increasing the confidence that each implementation conforms to the protocol specification. However, the specified protocol test suite cannot guarantee conformance to the specification since it detects errors rather than their absence. Thus conformance to a test suite alone cannot guarantee interworking. What it does do is give confidence that an implementation has the required capabilities and that its behavior conforms consistently in representative instances of communication.
NOTE 2 This document has some interdependencies to the conformance tests defined in ISO 15118-5 which result from ISO/OSI cross layer dependencies in the underlying protocol specification (e.g. for sleep mode)
- Standard1459 pagesEnglish languagesale 15% off
ISO 15118-8:2018 specifies the requirements of the physical and data link layer of a wireless High Level Communication (HLC) between Electric Vehicles (EV) and the Electric Vehicle Supply Equipment (EVSE). The wireless communication technology is used as an alternative to the wired communication technology as defined in ISO 15118‑3.
It covers the overall information exchange between all actors involved in the electrical energy exchange. ISO 15118 (all parts) are applicable for conductive charging as well as Wireless Power Transfer (WPT).
For conductive charging, only EVSEs compliant with "IEC 61851‑1 modes 3 and 4" and supporting HLC are covered by this document. For WPT, charging sites according to IEC 61980 (all parts) and vehicles according to ISO/PAS 19363 are covered by this document.
- Standard34 pagesEnglish languagesale 15% off
IEC 62576:2018 describes the methods for testing electrical characteristics of electric double-layer capacitor cells (hereinafter referred to as capacitor) to be used for peak power assistance in hybrid electric vehicles. This second edition cancels and replaces the first edition published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) information on applicability of this document has been added in Clause 1;
b) the definitions of some terms in Clause 3 have been improved;
c) the description of test procedures in Clause 4 has been clarified;
d) information on endurance cycling test has been added (Annex E).
- Standard90 pagesEnglish languagesale 15% off
- Standard60 pagesEnglish and French languagesale 15% off
IEC 61851-21-1:2017, together with IEC 61851-1:2010, gives requirements for conductive connection of an electric vehicle (EV) to an AC or DC supply. It applies only to on-board charging units either tested on the complete vehicle or tested on the charging system component level (ESA - electronic sub assembly).
This document covers the electromagnetic compatibility (EMC) requirements for electrically propelled vehicles in any charging mode while connected to the mains supply. This first edition, together with IEC 61851-21-2, cancels and replaces IEC 61851-21:2001. It constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 61851‑21:2001:
a) this document addresses now only EMC tests instead of other electrical tests;
b) test setups are defined more precisely;
c) Annex A "Artificial networks, asymmetric artificial networks and integration of charging stations into the test setup" was added.
- Standard47 pagesEnglish languagesale 15% off
- Standard95 pagesEnglish and French languagesale 15% off
IEC 61851-1:2017 applies to EV supply equipment for charging electric road vehicles, with a rated supply voltage up to 1 000 V AC or up to 1 500 V DC and a rated output voltage up to 1 000 V AC or up to 1 500 V DC. Electric road vehicles (EV) cover all road vehicles, including plug-in hybrid road vehicles (PHEV), that derive all or part of their energy from on-board rechargeable energy storage systems (RESS). The aspects covered in this standard include:
- the characteristics and operating conditions of the EV supply equipment;
- the specification of the connection between the EV supply equipment and the EV;
- the requirements for electrical safety for the EV supply equipment.
This third edition cancels and replaces the second edition published in 2010. It constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) The contents of IEC 61851-1:2010 have been re-ordered. Numbering of clauses has changed as new clauses were introduced and some contents moved for easy reading. The following lines give an insight to the new ordering in addition to the main technical changes.
b) All requirements from IEC 61851-22 have been moved to this standard, as work on IEC 61851-22 has ceased.
c) Any requirements that concern EMC have been removed from the text and are expected to be part of the future version of 61851-21-2.
d) Clause 4 contains the original text from IEC 61851-1:2010 and all general requirements from Clause 6 of IEC 61851-1:2010.
e) Clause 5 has been introduced to provide classifications for EV supply equipment.
f) Previous general requirements of Clause 6 have been integrated into Clause 4. Clause 6 contains all Mode descriptions and control requirements. Specific requirements for the combined use of AC and DC on the same contacts are included.
g) Clause 9 is derived from previous Clause 8. Adaptation of the description of DC accessories to allow for the DC charging modes that have only recently been proposed by industry and based on the standards IEC 61851-23, IEC 61851-24 as well as IEC 62196-1, IEC 62196-2 and IEC 62196-3. Information and tables contained in the IEC 62196 series standards have been removed from this standard.
h) Clause 10 specifically concerns the requirements for adaptors, initially in Clause 6.
i) Clause 11 includes new requirements for the protection of the cable.
j) Specific requirements for equipment that is not covered in the IEC 62752 remain in the present document.
k) Previous Clause 11 is now treated in Clauses 12 to 13. The requirements in 61851-1 cover the EV supply equipment of both mode 2 and mode 3 types, with the exception in-cable control and protection devices for mode 2 charging of electric road vehicles (IC-CPD) which are covered by IEC 62752.
l) Clause 14 gives requirements on automatic reclosing of protection equipment.
m) Clause 16 gives requirements for the marking of equipment and the contents of the installation and user manual. This makes specific mention of the need to maintain coherence with the standards for the fixed installation. It also contains an important text on the markings for temperature ratings.
n) Annex A has been reviewed to introduce complete sequences and tests and to make the exact cycles explicit. Annex A in this edition supersedes IEC TS 62763 (Edition 1).
o) Annex B is normative and has requirements for proximity circuits with and without current coding.
p) Previous Annex C has been removed and informative descriptions of pilot function and proximity function implementations initially in Annex B are moved to Annex C.
q) New informative Annex D describing an alternative pilot function system has been introduced.
r) Dimensional requirements for free space to be left around socket-outlets used for EV energy supply are given in the informative Annex E.
s) The inclusion of protection devices within the EV supply equipment could, in some cases, contribute to the
- Standard287 pagesEnglish and French languagesale 15% off
- Standard1 pageEnglish and French languagesale 15% off
IEC 62840-2:2016 provides the safety requirements for a battery swap system, for the purposes of swapping swappable battery system (SBS) of electric vehicles. The battery swap system is intended to be connected to the supply network. The power supply is up to 1 000 V AC or up to 1 500 V d.c, in accordance with IEC 60038. This standard also applies to battery swap systems supplied from on-site storage systems (e.g. buffer batteries).
This publication is to be read in conjunction with IEC 62840-1:2016.
- Standard53 pagesEnglish and French languagesale 15% off
IEC TS 62840-1:2016(E) gives the general overview for battery swap systems, for the purposes of swapping batteries of electric road vehicles (EVs) when the vehicle powertrain is turned off and when the battery swap system is connected to the supply network at standard supply voltages according to IEC 60038 with a rated voltage up to 1 000 V AC and up to 1 500 V DC. It is applicable for battery swap systems for EV equipped with one or more swappable battery system (SBS).
- Technical specification27 pagesEnglish languagesale 15% off
- Standard10 pagesEnglish and French languagesale 15% off
ISO 17409:2015 specifies electric safety requirements for conductive connections of electrically propelled road vehicles to an external electric power supply using a plug or vehicle inlet. It applies to electrically propelled road vehicles with voltage class B electric circuits. In general, it may apply to motorcycles and mopeds if no dedicated standards for these vehicles exist. It applies only to vehicle power supply circuits. It applies also to dedicated power supply control functions used for the connection of the vehicle to an external electric power supply. It does not provide requirements regarding the connection to a non-isolated d.c. charging station. It does not provide comprehensive safety information for manufacturing, maintenance, and repair personnel. The requirements when the vehicle is not connected to the external electric power supply are specified in ISO 6469-3. NOTE 1 This International Standard does not contain requirements for vehicle power supply circuits using protection by class II or double/reinforced insulation but it is not the intention to exclude such vehicle applications. NOTE 2 Requirements for EV supply equipment are specified in IEC 61851.
- Standard23 pagesEnglish languagesale 15% off
IEC 61980-1:2015 applies to the equipment for the wireless transfer of electric power from the supply network to electric road vehicles for purposes of supplying electric energy to the RESS (Rechargeable energy storage system) and/or other on-board electrical systems in an operational state when connected to the supply network, at standard supply voltages ratings per IEC 60038 up to 1 000 V a.c. and up to 1 500 V d.c. This standard also applies to Wireless Power Transfer (WPT) equipment supplied from on-site storage systems (e.g. buffer batteries, etc.).
This publication is to be read in conjunction with the IEC 61980 series.
The contents of the corrigendum of January 2017 have been included in this copy.
- Standard72 pagesEnglish languagesale 15% off
- Standard151 pagesEnglish and French languagesale 15% off
- Standard10 pagesEnglish and French languagesale 15% off
ISO 15118-3:2015 specifies the requirements of the physical and data link layer for a high-level communication, directly between battery electric vehicles (BEV) or plug-in hybrid electric vehicles (PHEV), termed as EV (electric vehicle) [ISO-1], based on a wired communication technology and the fixed electrical charging installation [Electric Vehicle Supply Equipment (EVSE)] used in addition to the basic signalling, as defined in [IEC-1]. It covers the overall information exchange between all actors involved in the electrical energy exchange. ISO 15118 (all parts) is applicable for manually connected conductive charging. Only "[IEC-1] modes 3 and 4" EVSEs, with a high-level communication module, are covered by this part of ISO 15118.
- Standard79 pagesEnglish languagesale 15% off
ISO 15118-2:2014 specifies the communication between battery electric vehicles (BEV) or plug-in hybrid electric vehicles (PHEV) and the Electric Vehicle Supply Equipment. The application layer message set defined in ISO 15118-2:2014 is designed to support the energy transfer from an EVSE to an EV. ISO 15118-1 contains additional use case elements describing the bidirectional energy transfer. The implementation of these use cases requires enhancements of the application layer message set defined herein. The purpose of ISO 15118-2:2014 is to detail the communication between an EV (BEV or a PHEV) and an EVSE. Aspects are specified to detect a vehicle in a communication network and enable an Internet Protocol (IP) based communication between EVCC and SECC. ISO 15118-2:2014 defines messages, data model, XML/EXI based data representation format, usage of V2GTP, TLS, TCP and IPv6. In addition, it describes how data link layer services can be accessed from a layer 3 perspective. The Data Link Layer and Physical Layer functionality is described in ISO 15118-3.
- Standard342 pagesEnglish languagesale 15% off
IEC 61851-23:2014, gives the requirements for d.c. electric vehicle (EV) charging stations, herein also referred to as "DC charger", for conductive connection to the vehicle, with an a.c. or d.c. input voltage up to 1 000 V a.c. and up to 1 500 V d.c. according to IEC 60038. It provides the general requirements for the control communication between a d.c. EV charging station and an EV. The requirements for digital communication between d.c. EV charging station and electric vehicle for control of d.c. charging are defined in IEC 61851-24.
Due to further technical developments in the field of electric vehicles charging, the requirements in IEC 61851-23:2014 to fulfill the safety objective "protection against electric shock" under single fault condition by limiting the capacitance energy, may not cover all possible combinations of charging stations and vehicles. Since the charging process links the charging infrastructure with the electric vehicle, the requirements laid down in ISO 17409:2015 are also relevant for the electrical safety of the charging process. The approach of limiting the capacitance energy will not be sufficient for the safety objective "protection against electric shock" under single fault condition in all relevant cases. Therefore, this warning is issued for both standards. It is as always strongly recommended that users of standards additionally perform a risk assessment. Specifically in this case, standards users shall select proper means to fulfill safety requirements in the system of charging station and electric vehicle.
This publication is to be read in conjunction with IEC 61851-1:2010. The contents of the corrigendum of May 2016 have been included in this copy.
- Standard159 pagesEnglish and French languagesale 15% off
IEC 61851-24:2014, together with IEC 61851-23, applies to digital communication between a d.c. EV charging station and an electric road vehicle (EV) for control of d.c. charging, with an a.c. or d.c. input voltage up to 1 000 V a.c. and up to 1 500 V d.c. for the conductive charging procedure. The EV charging mode is mode 4, according to IEC 61851-23. Annexes A, B, and C give descriptions of digital communications for control of d.c. charging specific to d.c. EV charging systems A, B and C as defined in Part 23. The contents of the corrigendum of June 2015 have been included in this copy.
- Standard63 pagesEnglish and French languagesale 15% off
ISO 15118 specifies the communication between Electric Vehicles (EV), including Battery Electric Vehicles and Plug-In Hybrid Electric Vehicles, and the Electric Vehicle Supply Equipment (EVSE). As the communication parts of this generic equipment are the Electric Vehicle Communication Controller (EVCC) and the Supply Equipment Communication Controller (SECC), ISO 15118 describes the communication between these components. Although ISO 15118 is oriented to the charging of electric road vehicles, it is open for other vehicles as well. ISO 15118-1:2013 specifies terms and definitions, general requirements and use cases as the basis for the other parts of ISO 15118. It provides a general overview and a common understanding of aspects influencing the charge process, payment and load levelling. ISO 15118 does not specify the vehicle internal communication between battery and charging equipment and the communication of the SECC to other actors and equipment (beside some dedicated message elements related to the charging). All connections beyond the SECC, and the method of message exchanging are considered to be out of the scope as specific use cases.
- Standard65 pagesEnglish languagesale 15% off
This standard specifies the general performance requirements of all electrical measuring relays and protection equipment used in the electrotechnical fields covered by the IEC. Supersedes IEC 60255-6 (1978) and its first supplement 60255-6 A (1980).
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
Definitions. Standard values relating to energizing quantities influencing quantities. Fundamental characteristics relating to temperature rises and behaviour in service. Accuracy requirements relating to the characteristic quantity and specified times. Mechanical and electrical requirements. Markings and data. Methods of measurement.[
]The contents of the corrigendum of September 1992 have been included in this copy.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61851-1:2010 applies to on-board and off-board equipment for charging electric road vehicles at standard a.c. supply voltages (as per IEC 60038) up to 1 000 V and at d.c. voltages up to 1 500 V, and for providing electrical power for any additional services on the vehicle if required when connected to the supply network. It includes characteristics and operating conditions of the supply device and the connection to the vehicle; operators and third party electrical safety, and the characteristics to be complied with by the vehicle with respect to the a.c./d.c. EVSE, only when the EV is earthed. This second edition cancels and replaces the first edition published in 2001. It constitutes a technical revision. The main changes with respect to the first edition of this standard are:
- revision of connector definitions and current levels (Clause 8);
- modification definition of pilot wire to pilot function;
- division of Clause 9 to create Clauses 9 and 11;
- Clause 9: specific requirements for inlet, plug and socket-outlet;
- Clause 11: EVSE requirements: the basic generic requirements for charging stations;
- renumbering of annexes;
- deletion of previous Annex A and integration of charging cable requirements into new Clause 10;
- Annex B becomes Annex A and is normative for all systems using a PWM pilot function with a pilot wire; Annex C becomes Annex B;
- replacement of previous Annex D (coding tables for power indicator) with B.4 in Annex B using new values;
- new informative Annex C describing an alternative pilot function system.
This publication is of high relevance for Smart Grid.
- Standard99 pagesEnglish and French languagesale 15% off
IEC 62576:2009 describes the methods for testing electrical characteristics of electric double-layer capacitor cells (hereinafter referred to as capacitor) to be used for peak power assistance in hybrid electric vehicles.
- Standard51 pagesEnglish and French languagesale 15% off
Applies to equipment for charging electric road vehicles at standard a.c.supply voltages (as per IEC 60038) up to 690 V and at d.c. voltages up to 1 000 V, and for providing electrical power for any additional services on the vehicle if required when connected to the supply network.
- Standard39 pagesEnglish languagesale 15% off
- Standard77 pagesEnglish and French languagesale 15% off
IEC TS 61980-3:2019 applies to the equipment for the magnetic field wireless power transfer (MF-WPT) of electric power from the supply network to electric road vehicles for purposes of supplying electric energy to the RESS (rechargeable energy storage system) and/or other on-board electrical systems. The MF-WPT system operates at standard supply voltages ratings per IEC 60038 up to 1 000 V AC and up to 1 500 V DC The power transfer takes place while the electric vehicle (EV) is stationary.
This document also applies to MF-WPT equipment supplied from on-site storage systems (e.g. buffer batteries) at standard supply voltages ratings per IEC 60038 up to 1 000 V AC and up to 1 500 V DC.
The aspects covered in this document include
– the characteristics and operating conditions,
– the required level of electrical safety,
– requirements for basic communication for safety and process matters if required by a MF-WPT system,
– requirements for positioning to assure efficient and safe MF-WPT power transfer, and
– specific EMC requirements for MF-WPT systems.
The following aspects are under consideration for future documents:
– requirements for two- and three-wheel vehicles,
– requirements for MF-WPT systems supplying power to EVs in motion, and
– requirements for bidirectional power transfer.
This standard does not apply to
– safety aspects related to maintenance, and
– trolley buses, rail vehicles and vehicles designed primarily for use off-road.
- Technical specification107 pagesEnglish languagesale 15% off
IEC TS 61980-2:2019 applies to communication between electric road vehicle (EV) and wireless power transfer (WPT) systems when connected to the supply network, at standard supply voltages per IEC 60038 up to 1000 V AC and up to 1500 V DC.
This document also applies to wireless power transfer equipment supplied from on-site storage systems (e.g. buffer batteries) at standard supply voltages per IEC 60038 up to 1000 V AC and up to 1500 V DC.
The aspects covered in this document include
– standards for operational characteristics and functional characteristics of the WPT communication subsystem,
– communication requirements for WPT system while driving, which are under consideration,
– communication requirements for two- and three-wheel vehicles, which are under consideration, and
– communication requirements for bidirectional power transfer are under consideration
This document does not apply to
– safety aspects related to maintenance, and
– trolley buses, rail vehicles and vehicles designed primarily for use off-road.
- Technical specification84 pagesEnglish languagesale 15% off
IEC/TS 62763:2013(E) describes the pilot wire function designed as a control mechanism for the supply of electrical energy to electric vehicles, principally for the charging of the traction batteries of the vehicle. It concerns all charging systems that ensure the pilot function with a pilot wire circuit with PWM for mode 2, mode 3 and mode 4 charging as described in the IEC 61851 series.
- Technical specification32 pagesEnglish languagesale 15% off
This part of IEC 61851, together with part 1, gives the requirements for a.c. electric vehicle charging stations for conductive connection to an electric vehicle, with a.c. supply voltages according to IEC 60038 up to 690 V.
This publication is of high relevance for Smart Grid.
- Standard41 pagesEnglish and French languagesale 15% off