This European Standard deals with the requirements and the basic performance criteria for blocks made in expanded polystyrene (EPS), used in conjunction with precast concrete beams in compliance with
EN 15037-1, with or without cast-in-situ concrete for the construction of beam-and-block floor systems.
EPS block may be totally made in EPS or combined with different materials such as plaster or wood wool.
If EPS is combined with other materials, these materials should not contribute to more than 50 % of the mechanical resistance of the block. If not, the block is covered by EN 15037-5, Precast concrete products - Beam-and-block floor systems - Part 5: Lightweight blocks for simple formwork.
Examples of typology of floor systems are given in Annex B of EN 15037-1:2008.

  • Standard
    55 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the requirements and the basic performance criteria for lightweight blocks used as formwork during the construction of the floor system. The blocks are used in conjunction with precast concrete beams in compliance with EN 15037-1, with or without cast-in-situ concrete for the construction of beam-and-block floor systems.
This European Standard does not deal with blocks made in polystyrene, with or without tong, or combined with different materials where polystyrene contributes to more than 50 % of the mechanical resistance of the block. These blocks are covered by EN 15037-4, Precast concrete products — Beam-and-block floor systems  Part 4: Expanded polystyrene blocks.
Examples of typology of floor systems are given in Annex B of EN 15037-1:2008.

  • Standard
    58 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard identifies the requirements, the basic performance criteria and evaluation of conformity for precast linear elements (such as columns, beams and frame elements) made of reinforced or prestressed normal or lightweight concrete, used for the construction of the structures of buildings and other civil engineering works, except bridges.
This document covers terminology, performance criteria, tolerances, relevant physical properties, test methods, and aspects of transport and erection.
This document does not cover load bearing capacity determined by testing.
This standard does not cover lintels with length up to 4,5 m used in masonry walls.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with both large (structural) and small (non-structural or light structural) box culverts of rectangular cross-section formed monolithically and designed as continuous elements with a joint detail shaped to allow the possible incorporation of sealing materials. Box culverts can be used for creation of voids below ground for conveyance and storage of materials. e.g. conveyance and storage of wastewater, cable tunnels and subways
For the purposes of this European Standard, box culverts having internal cross-sectional dimensions (W and H in Figure 1) less than or equal to 1 250 mm are considered as small (non-structural or light structural). All other units are defined as large. The elements are generally manufactured in factories using either normal weight or lightweight concrete and usually require reinforcing steel. This standard does not include units manufactured from autoclaved aerated concrete, nor prefabricated reinforced box culverts of lightweight concrete with open structure.
Each unit is structurally complete. They are used in combination to form a total structure of appropriate length (including joints) and capacity.

  • Standard
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document identifies the requirements, the basic performance criteria and evaluation of conformity for precast ribbed elements made of reinforced or prestressed normal weight concrete, used in floors or roofs. The elements consist of a top and/or bottom slab and one or more (usually two) ribs; transverse ribs may also be present.
Some examples of precast elements considered in this document are shown in Annex A.
Specific requirements for minor floor elements are listed in Annex B.
This document covers terminology, performance criteria, tolerances, relevant physical properties, test methods and aspects of transport and erection.
This document does not cover load-bearing capacity determined by testing.

  • Standard
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the requirements and the basic performance criteria and specifies minimum values where appropriate for precast hollow core slabs made of prestressed or reinforced normal weight concrete according to EN 1992-1-1:2004.
This European Standard covers terminology, performance criteria, tolerances, relevant physical properties, special test methods, and special aspects of transport and erection.
Hollow core elements are used in floors, roofs, walls and similar applications. In this European Standard the material properties and other requirements for floors and roofs are dealt with; for special use in walls and other applications, see the relevant product standards for possible additional requirements.
The elements have lateral edges with a grooved profile in order to make a shear key to transfer shear through joints contiguous elements. For diaphragm action the joints have to function as horizontal shear joints.
To improve this action vertical grooves may be provided.
The elements are manufactured in factories by extrusion, slipforming or mouldcasting. Fitting slabs (narrowed slab elements) and recesses to the hollow core slabs can be made during production or afterwards. Hollow core slabs can have provisions for thermal activation, heating, cooling, sound insulation, etc. Due to these provisions, the concrete temperature remains in it’s natural range.
This European Standard also deals with solid slab elements used in conjunction with hollow core slabs and manufactured by extrusion, slipforming or mouldcasting, equivalent to the manufacturing of hollow core slabs. These solid slabs have the same overall cross-section as hollow core slabs, however without hollow cores.
The application of the standard is limited for prestressed elements to a maximum depth of 500 mm and for reinforced elements to a maximum depth of 300 mm.
For both types, the maximum width without transverse reinforcement is limited to 1 200 mm and with transverse reinforcement to 2 400 mm.
The elements may be used in composite action with an in situ structural topping cast on site.
The applications considered are floors and roofs of buildings, including areas for vehicles in the category F and G of EN 1991-1-1 which are not subjected to fatigue loading. For building in seismic zones additional provisions are given in EN 1998-1.
This European Standard does not deal with complementary matters. E.g. the slabs should not be used in roofs without additional protection against water penetration.

  • Standard
    81 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard applies to prefabricated walls, made of normal weight or lightweight concrete with dense structure. Also fibre reinforced concrete (steel, polymer or other fibres covered by European standards) may be used. These wall elements may have external wall functions (see 3.11) or not, have facing functions (see 3.12) or not or have a combination of these functions.
External wall functions could be:
-   thermal insulation (see 3.11.1);
-   sound insulation (see 3.11.2);
-   hygrometric control (see 3.11.3);
or a combination of these.
They may be plain, reinforced or prestressed. They may be loadbearing or not.
These include:
-   solid walls;
-   composite walls;
-   sandwich walls;
-   lightened walls;
-   claddings.
The wall element may also work as a column or beam.

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard specifies precast products in reinforced or pre-stressed concrete with or without fibres, to be used together or in combination with other elements to erect fences e.g. boundary fences.
This European standard covers both mechanical resistance determined by calculation and load bearing capacity determined by testing.
Normal weight concrete or light weight concrete elements include posts, solid or open panels, slabs, rails, spurs, struts and base panels.
The intended uses may be nonstructural or lightly structural.
It provides for the evaluation of conformity of elements to this European Standard. Marking conditions are included.

  • Standard
    52 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard applies to precast concrete structural elements produced in a factory and used in bridge construction, such as deck elements.Normal weight concrete elements are considered, both reinforced and prestressed; their use can be on road bridges, railway bridges and footbridges.
Deck elements include both single elements from which the deck may be composed (beams, slabs, ribbed or cellular elements) and elements consisting of a segment of the entire deck.
Some examples of elements dealt with are shown in Annex A.
The durability aspects are also considered.
This European Standard makes reference to precast elements produced in a factory or near the construction site in a place protected from adverse weather conditions. It is assumed that if the elements are not manufactured in a factory, the production conditions assure the same level of quality control as in a factory. It is assumed that the production place is protected from rain, sunshine and wind.
Some of the elements are also treated in other European Standards (e.g. beams, slabs). This European Standard deals with the specific aspects related to the use of these elements in bridge construction.
Foundation piles, piers, abutments, barriers, bumpers, guards, arches and" box culverts are out the scope of this European Standard.

  • Standard
    60 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the requirements and the basic performance criteria for blocks made in normal or lightweight aggregate concrete, used in conjunction with precast concrete beams in compliance with EN 15037-1, with or without cast-in-situ concrete for the construction of beam-and-block floor and roof systems.
Examples of typology of floor and roof systems are given in Annex B of EN 15037-1:2008.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the requirements and the basic performance criteria for blocks made in clay, used in conjunction with precast concrete beams in compliance with EN 15037-1, with or without cast-in-situ concrete for the construction of beam-and-block floor and roof systems.
Examples of typology of floor and roof systems are given in Annex B of EN 15037-1:2008.

  • Standard
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the requirements, the basic performance criteria and evaluation of conformity for precast beams made of reinforced or prestressed normal or lightweight concrete according to EN 1992-1-1:2004, with or without clay shell, used in conjunction with blocks in compliance with prEN 15037-2 or prEN 15037-3 or prEN 15037-4 or prEN 15037-5, with or without cast in-situ concrete for the construction of beam-and-block floor and roof systems. Examples of typology of floor and roof systems are given in Annex B.
It is essential that the total depth of the beam be comprised between 60 mm and 300 mm and the beams be at centres of not more than 1,00 m.
For higher depth, it is essential that the precast concrete beams be in compliance with EN 13225.
The products covered by this standard are intended to be used as structural floor and roof systems, including parking areas for light vehicles corresponding to traffic category F of EN 1991-1-1:2002, which are not subjected to fatigue loading.
The products may be used in seismic areas provided they fulfil the requirements specific to this use.

  • Standard
    93 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the requirements, the basic performance criteria and evaluation of conformity for precast elements made of plain, reinforced or prestressed normal weight concrete, used for the construction of retaining walls.
The products covered by this European Standard are intended to be used as part of retaining walls in applications such as:
- to retain natural ground excavations and trenches;
- to retain earth fills for roads, platforms, etc.;
- in bridge abutments and their flank walls;
- to retain several kinds of loose materials such as sand, gravel, etc.
Some examples of precast elements considered in this European Standard are shown in the Informative Annex B.
The products may be used in seismic areas on condition that they fulfil the requirements specific to this use.
This European Standard does not cover:
- products for retaining walls of tanks or reservoirs of liquids;
- retaining wall elements up to a height of 1,0 m and those assembled to form retaining walls of up to 1,0 m in height (e.g. stacked flower boxes for dwarf walls) if the corresponding retaining wall is used for secondary loads (max. horizontal earth fill and with light surcharge);
- products for stacked planting boxes, having only façade functions, and therefore not submitted to any loads (such as earth pressure loads, highway load effects, etc.);
- precast diaphragm walls (concrete sheet piling).

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    32 pages
    German language
    sale 10% off
    e-Library read for
    1 day

This document identifies the requirements, the basic performance criteria and the evaluation of conformity for special precast roof elements made of reinforced or prestressed normal weight concrete, used for the construction of buildings, with or without separating function with respect to fire resistance.
NOTE   The title of special roof elements refers to thin-walled structural elements with deformable transverse profile, such as folded plates, or shell elements, the intended use being specific for roofings with their typical loads. This type of elements combines the overall flexural behaviour along the main span with a complex distribution of in-plane forces and local moments.
Other types of elements can be used in roofing, such as ribbed units, floor slabs, ... . For these elements reference shall be made to their respective product standards.
!This document identifies also the requirements, the basic performance criteria and the evaluation of conformity of complementary elements made of reinforced or prestressed normal weight concrete, possibly used in combination with the main roof elements, such as load bearing shuttering plates and shells, for which reference shall be made to Annex F."Secondary structural components, possibly used in combination with the main roof elements, such as load bearing shuttering plates and shells, roof light frames, ..., shall refer to their respective product standard or technical approval.
This document covers terminology, performance criteria, tolerances, relevant physical properties, test methods, and aspects of transport and erection.
This document does not deal with seismic behaviour.
This document does not cover load bearing capacity determined by testing.

  • Standard
    58 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for reinforced and prestressed precast concrete floor slats used in slatted floors for the housing of livestock and provides for the evaluation of conformity of these products. This standard does not cover slats for loadings other than stock and stockmen.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the terminology, requirements, basic performance criteria, test methods and evaluation of conformity that will be applied to precast concrete foundation piles, factory produced for building and civil engineering works and installed at the site by the use of impact, vibration, pressing or other suitable techniques. This document may also be applied to products manufactured in temporary plants on site where production is controlled in accordance with the provisions of Clause 6 and is protected against adverse weather conditions as necessary.
This document applies to foundation piles produced in a plant as reinforced or prestressed concrete elements. The cross-section may be solid or provided with a hollow core, either prismatic or cylindrical. The cross-section may be constant over the full length or tapered partly or wholly along the pile or pile segment length.
This document deals with foundation piles manufactured either in one length or in segments with cast-in pile joints. The foundation piles may have an enlarged toe or a pile shoe.
This document applies to normal weight concrete as defined in EN 206-1 compacted so as to retain no appreciable amount of entrapped air other than entrained air.

  • Standard
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard gives specifications for materials, production, properties, requirements and methods of testing for precast concrete monolithic stairs, and for precast concrete elements (e.g. individual steps) used to make reinforced and/or prestressed concrete stairs.
This standard is applicable to structural stairs for indoor or outdoor use.
This standard covers precast concrete stairs and associated landings of monolithic design or constructed from individual steps supported by beams or columns. Supporting elements may include in situ concrete.
This standard covers terminology, performance criteria, verification methods, tolerances, relevant physical properties, special test methods and specific aspects of transport, erection and connection.
Geometrical properties related to functionality of stairs are not covered by this standard and can be found in National regulations or local practice.
Precast concrete stairs are classified into two main product families :
   monolithic stairs constructed from precast concrete components consisting of flights, landings or a combination of these. They may include vertical supporting elements ;
   stairs constructed from individual steps, whether load bearing or not, assembled on site with, for example, carriages or a central column.
Their shape may be straight or winding.
Stairs may incorporate parapets (on one or both sides) and landings.
Stairs may have simple bearings (e.g. on corbels, walls or beams), bolted connections or they may be connected with reinforcement and in situ concrete.
The surfaces of the precast elements may be exposed or covered by finishes.

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the requirements and the basic performance criteria and specifies where applicable minimum values for precast foundation elements (comprising columns with integrated foundation elements, pocket foundation elements, sockets) made of reinforced normal weight concrete for structure of buildings according to EN 1992-1-1.
This European Standard covers terminology, performance criteria, tolerances, relevant physical properties and special aspects of transport and erection.
This European Standard does not cover the bearing capacity determined by testing.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document regards precast reinforced concrete garages produced as monolithic units or as kits of single sections with room dimensions in stationary factories. These garages are intended to be erected on foundations designed by others and complying with the behaviour of the precast units. They may be free-standing, or may have backfilling behind some of the walls (earthfilled), or earth covered or built over with a parking area for cars or a second storey of precast garages. This document also applies to supplementary units, kits for double space garages and multiple parking garages as well as for garage boxes for one-storey basement garages. It does not apply to elements incorporated as a structural part of an upper structure unless they are designed according to EN 13369.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Standard specifies requirements for precast concrete poles (also commonly called masts) (either all of a piece or composed of elements), reinforced and/or prestressed as structural elements; they may be hollow or solid and may receive or include additional components (e.g. cross-arms, platforms etc.), inserts and connectors. Additional elements may be connected to pole elements.
Structures made from such elements in mono- or multi-legged form may be used for :
- overhead electrical lines ;
- telecommunication lines ;
- overhead electrical lines for railways, trams and similar ;
- supports for lighting ;
- supports for loudspeaker installation ;
- antenna and telecommunication poles ;
- supports for wind turbines ;
- and similar installations.
This Standard does not cover lighting columns for use in traffic circulation areas.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

20080320 - Document removed from the production line - CEN/TC 229 to deliver new annex ZA
2007-07-27:ADC: DAW= DAV+21 months

  • Draft
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Modification of the scope of EN 13747:2005 (lowering the minimum thickness of prestressed elements down to 40 mm).

  • Draft
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard covers precast products in reinforced or prestressed concrete with or without fibres, produced in long series with the same design and mechanical resistance verified by testing to be used together or in combination with other elements to erect fences e.g. boundary fences. Normal weight concrete or light weight concrete elements include posts, solid or open panels, slabs, rails, spurs, struts and base panels. The intended uses may be nonstructural or lightly structural. It provides for the evaluation of conformity of elements to this European Standard. Marking conditions are included. NOTE Annex A intends to provide information on the possible types of fences in which these elements may be part of.

  • Draft
    54 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Amendments on shear verification, thermal prestressing method, slabs > 2400/1200, transverse load distribution, fire resistance, slabs with variable depth

  • Draft
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Amendments to include fiber reinforced concrete in the scope and to define which elements are under attestation of conformity systems 2+ and 4

  • Draft
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

A series of modifications regarding production tolerances.

  • Draft
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the requirements and the basic performance criteria for blocks made in expanded polystyrene (EPS), used in conjunction with precast concrete beams in compliance with EN 15037-1, with or without cast-in-situ concrete for the construction of beam-and-block floor systems. EPS block may be totally made in EPS or combined with different materials such as plaster or wood wool. If EPS is combined with other materials, these materials should not contribute to more than 50 % of the mechanical resistance of the block. If not, the block is covered by EN 15037-5, Precast concrete products - Beam-and-block floor systems - Part 5: Lightweight blocks for simple formwork. Examples of typology of floor systems are given in Annex B of EN 15037-1:2008.

  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Removal of bridge abutments from the scope of the standard

  • Draft
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Amendments regarding shear and torsion, elements deeper than 450 mm and revised Annex J "Full scale test".

  • Draft
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard identifies the requirements, the basic performance criteria and the evaluation of conformity for special precast roof elements made of reinforced or prestressed normal weight concrete, used for the construction of buildings, with or without separating function with respect to fire resistance.
NOTE   The title of special roof elements refers to thin-walled structural elements with deformable transverse profile, such as folded plates, or shell elements, the intended use being specific for roofings with their typical loads. This type of elements combines the overall flexural behaviour along the main span with a complex distribution of in-plane forces and local moments.
Other types of elements can be used in roofing, such as ribbed units, floor slabs, ... . For these elements reference shall be made to their respective product standards.
Secondary structural components, possibly used in combination with the main roof elements, such as load bearing shuttering plates and shells, roof light frames, ..., shall refer to their respective product standard or technical approval.
The standard covers terminology, performance criteria, tolerances, relevant physical properties, test methods, and aspects of transport and erection.
This standard does not deal with seismic behaviour.
This standard does not cover load bearing capacity determined by testing.

  • Draft
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Change to the scope in order to distinguish between structural and non-structural wall elements, AoC system 2+ and 4, and inclusion of EN 206-1:2000 in clause 2 Normative references

  • Draft
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the requirements and the basic performance criteria for blocks made in expanded polystyrene (EPS), used in conjunction with precast concrete beams in compliance with
EN 15037-1, with or without cast-in-situ concrete for the construction of beam-and-block floor systems.
EPS block may be totally made in EPS or combined with different materials such as plaster or wood wool.
If EPS is combined with other materials, these materials should not contribute to more than 50 % of the mechanical resistance of the block. If not, the block is covered by EN 15037-5, Precast concrete products - Beam-and-block floor systems - Part 5: Lightweight blocks for simple formwork.
Examples of typology of floor systems are given in Annex B of EN 15037-1:2008.

  • Standard
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day

TC - Modification to scope

  • Corrigendum
    2 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Standard identifies the requirements, the basic performance criteria and evaluation of conformity for precast linear elements (such as columns, beams and frame elements) made of reinforced or prestressed normal weight concrete, used for the construction of the structures of buildings and other civil engineering works, except bridges.
This Standard covers terminology, performance criteria, tolerances, relevant physical properties, test methods, and aspects of transport and erection.
This Standard does not cover load bearing capacity determined by testing.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    29 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

This European Standard applies to precast concrete structural elements produced in a factory and used in bridge construction, for example deck elements, abutments, elements for piers and precast arches.
Normal weight concrete elements are considered, both reinforced and prestressed; their use can be on road bridges, railway bridges and footbridges.
Deck elements include both single elements from which the deck may be composed (beams, slabs, ribbed or cellular elements) and elements consisting of a segment of the entire deck.
The elements for abutments are precast elements able to support vertical and horizontal actions applied by the deck and the earth pressure due to the filling material.
The pier elements can consist of a segment of the pier or, for small heights, the entire pier.
Some examples of elements dealt with are shown in Annex A.
The durability aspects are also considered.
This European Standard makes reference to precast elements produced in a factory or near the construction site in a place protected from adverse weather conditions. It is assumed that if the elements are not manufactured in a factory, the production conditions assure the same level of quality control as in a factory. It is assumed that the production place is protected from rain, sunshine and wind.
Some of the elements are also treated in other European Standards (e.g. beams, slabs). This European Standard deals with the specific aspects related to the use of these elements in bridge construction.
Foundation piles, barriers, bumpers, guards and box culverts are out the scope of this European Standard.

  • Standard
    60 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard deals with both large (structural) and small (non-structural or light structural) box culverts of rectangular cross-section formed monolithically and designed as continuous elements with a joint detail shaped to allow the possible incorporation of sealing materials. Box culverts can be used for creation of voids below ground for conveyance and storage of materials. e.g. conveyance and storage of wastewater, cable tunnels and subways
For the purposes of this standard, box culverts having internal cross-sectional dimensions (W and H in Figure 1) less than or equal to 1 250 mm should be considered as small (non-structural or light structural). All other units should be defined as large. The elements are generally manufactured in factories using either normal weight or lightweight concrete and usually require reinforcing steel. This standard does not include units manufactured from autoclaved aerated concrete, nor prefabricated reinforced box culverts of lightweight concrete with open structure.
Each unit is structurally complete. They are used in combination to form a total structure of appropriate length (including joints) and capacity.

  • Standard
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document identifies the requirements, the basic performance criteria and evaluation of conformity for precast ribbed elements made of reinforced or prestressed normal weight concrete, used in floors or roofs. The elements consist of a top slab and one or more (usually two) ribs, containing the main longitudinal reinforcement; a bottom slab and transverse ribs may also be present.
Some examples of precast elements considered in this document are shown in the Informative Annex A.
This document covers terminology, performance criteria, tolerances, relevant physical properties, test methods and aspects of transport and erection.
This document does not cover load bearing capacity determined by testing.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the requirements and the basic performance criteria and specifies minimum values where appropriate for precast hollow core slabs made of prestressed or reinforced normal weight concrete according to EN 1992-1-1:2004.
This European Standard covers terminology, performance criteria, tolerances, relevant physical properties, special test methods, and special aspects of transport and erection.
Hollow core elements are used in floors, roofs, walls and similar applications. In this European Standard the material properties and other requirements for floors and roofs are dealt with; for special use in walls and other applications, see the relevant product standards for possible additional requirements.
The elements have lateral edges provided with a longitudinal profile in order to make a shear key for transfer of vertical shear through joints between contiguous elements. For diaphragm action the joints have to function as horizontal shear joints.
The elements are manufactured in factories by extrusion, slipforming or mouldcasting.
The application of the standard is limited for prestressed elements to a maximum depth of 500 mm and a maximum width of 1 200 mm. For reinforced elements the maximum depth is limited to 300 mm and the maximum width without transverse reinforcement to 1 200 mm and with transverse reinforcement to 2 400 mm.
The elements may be used in composite action with an in situ structural topping cast on site.
The applications considered are floors and roofs of buildings, including areas for vehicles in the category F and G of EN 1991-2 which are not subjected to fatigue loading. For building in seismic zones additional provisions are given in EN 1998-1.
This European Standard does not deal with complementary matters. E.g. the slabs should not be used in roofs without additional protection against water penetration.

  • Standard
    70 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard deals with the requirements, the basic performance criteria and evaluation of conformity for precast floor plates made of reinforced or prestressed normal weight concrete according to EN 1992 1 1:2004, used in conjunction with cast-in-situ concrete (topping) for the construction of composite floor slabs. Annex B gives different types of composite slabs made with floor plates.
These floor plates, with or without void formers, can include lattice girders or stiffening ribs incorporated during the precasting.
They shall be manufactured in factories by casting, slip forming or extrusion.
The products covered by this standard are intended to be used as part of structural floors in applications such as:
-   floors and roofs of buildings (including industrial and storage buildings, public buildings as schools, hospitals, etc.);
-   parking/circulation areas;
-   cover for culverts;
-   etc.
The products may be used in seismic areas provided they fulfil the requirements specific to this use.
This standard does not cover:
-   reinforced and prestressed floor plates with a nominal thickness less than 40 mm;
-   prestressed floor plates with a nominal thickness less than 50 mm without stiffening ribs or lattice girder;
-   floor plates with a very smooth upper face, such as defined in 6.2.5 of EN 1992-1-1:2004.

  • Standard
    87 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard identifies the requirements, the basic performance criteria and the evaluation of conformity for special precast roof elements made of reinforced or prestressed normal weight concrete, used for the construction of buildings, with or without separating function with respect to fire resistance.
NOTE   The title of special roof elements refers to thin-walled structural elements with deformable transverse profile, such as folded plates, or shell elements, the intended use being specific for roofings with their typical loads. This type of elements combines the overall flexural behaviour along the main span with a complex distribution of in-plane forces and local moments.
Other types of elements can be used in roofing, such as ribbed units, floor slabs, ... . For these elements reference shall be made to their respective product standards.
Secondary structural components, possibly used in combination with the main roof elements, such as load bearing shuttering plates and shells, roof light frames, ..., shall refer to their respective product standard or technical approval.
The standard covers terminology, performance criteria, tolerances, relevant physical properties, test methods, and aspects of transport and erection.
This standard does not deal with seismic behaviour.
This standard does not cover load bearing capacity determined by testing.

  • Standard
    52 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the requirements and the basic performance criteria and specifies minimum
values where appropriate for precast hollow core slabs made of prestressed or reinforced normal weight concrete
according to EN 1992-1-1:2004.
This European Standard covers terminology, performance criteria, tolerances, relevant physical properties, special
test methods, and special aspects of transport and erection.
Hollow core elements are used in floors, roofs, walls and similar applications. In this European Standard the
material properties and other requirements for floors and roofs are dealt with; for special use in walls and other
applications, see the relevant product standards for possible additional requirements.
The elements have lateral edges provided with a longitudinal profile in order to make a shear key for transfer of
vertical shear through joints between contiguous elements. For diaphragm action the joints have to function as
horizontal shear joints.
The elements are manufactured in factories by extrusion, slipforming or mouldcasting.
The application of the standard is limited for prestressed elements to a maximum depth of !500" mm and a
maximum width of 1 200 mm. For reinforced elements the maximum depth is limited to 300 mm and the maximum
width without transverse reinforcement to 1 200 mm and with transverse reinforcement to 2 400 mm.
The elements may be used in composite action with an in situ structural topping cast on site.
The applications considered are floors and roofs of buildings, including areas for vehicles in the category F and G
of EN 1991-2 which are not subjected to fatigue loading. For building in seismic zones additional provisions are
given in EN 1998-1.
This European Standard does not deal with complementary matters. E.g. the slabs should not be used in roofs
without additional protection against water penetration.

  • Standard
    63 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard deals with both large (structural) and small (non-structural or light structural) box culverts of rectangular cross-section formed monolithically and designed as continuous elements with a joint detail shaped to allow the possible incorporation of sealing materials. Box culverts can be used for creation of voids below ground for conveyance and storage of materials. e.g. conveyance and storage of wastewater, cable tunnels and subways
For the purposes of this standard, box culverts having internal cross-sectional dimensions (W and H in Figure 1) less than or equal to 1 250 mm should be considered as small (non-structural or light structural). All other units should be defined as large. The elements are generally manufactured in factories using either normal weight or lightweight concrete and usually require reinforcing steel. This standard does not include units manufactured from autoclaved aerated concrete, nor prefabricated reinforced box culverts of lightweight concrete with open structure.
Each unit is structurally complete. They are used in combination to form a total structure of appropriate length (including joints) and capacity.

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the requirements and the basic performance criteria and specifies minimum values where appropriate for precast hollow core slabs made of prestressed or reinforced normal weight concrete according to EN 1992-1-1:2004.
This European Standard covers terminology, performance criteria, tolerances, relevant physical properties, special test methods, and special aspects of transport and erection.
Hollow core elements are used in floors, roofs, walls and similar applications. In this European Standard the material properties and other requirements for floors and roofs are dealt with; for special use in walls and other applications, see the relevant product standards for possible additional requirements.
The elements have lateral edges provided with a longitudinal profile in order to make a shear key for transfer of vertical shear through joints between contiguous elements. For diaphragm action the joints have to function as horizontal shear joints.
The elements are manufactured in factories by extrusion, slipforming or mouldcasting.
The application of the standard is limited for prestressed elements to a maximum depth of 450 mm and a maximum width of 1 200 mm. For reinforced elements the maximum depth is limited to 300 mm and the maximum width without transverse reinforcement to 1 200 mm and with transverse reinforcement to 2 400 mm.
The elements may be used in composite action with an in situ structural topping cast on site.
The applications considered are floors and roofs of buildings, including areas for vehicles in the category F and G of EN 1991-2 which are not subjected to fatigue loading. For building in seismic zones additional provisions are given in EN 1998-1.
This European Standard does not deal with complementary matters. E.g. the slabs should not be used in roofs without additional protection against water penetration.

  • Standard
    59 pages
    English language
    sale 10% off
    e-Library read for
    1 day

TC - Modification in ZA.2.1

  • Corrigendum
    2 pages
    English, French and German language
    sale 10% off
    e-Library read for
    1 day

This standard identifies the requirements, the basic performance criteria and evaluation of conformity for precast ribbed elements made of reinforced or prestressed normal weight concrete, used in floors or roofs. The elements consist of a top slab and one or more (usually two) ribs, containing the main longitudinal reinforcement; a bottom slab and transverse ribs may also be present.
Some examples of precast elements considered in this Standard are shown in the Informative Annex A.
This standard covers terminology, performance criteria, tolerances, relevant physical properties, test methods and aspects of transport and erection.
This standard does not cover load bearing capacity determined by testing.

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the terminology, requirements, basic performance criteria, test methods and evaluation of conformity that will be applied to precast concrete foundation piles, factory produced for building and civil engineering works and installed at the site by the use of impact, vibration, pressing or other suitable techniques. This document may also be applied to products manufactured in temporary plants on site where production is controlled in accordance with the provisions of Clause 6 and is protected against adverse weather conditions as necessary.
This document applies to foundation piles produced in a plant as reinforced or prestressed concrete elements. The cross-section may be solid or provided with a hollow core, either prismatic or cylindrical. The cross-section may be constant over the full length or tapered partly or wholly along the pile or pile segment length.
This document deals with foundation piles manufactured either in one length or in segments with cast-in pile joints. The foundation piles may have an enlarged toe or a pile shoe.
This document applies to normal weight concrete as defined in EN 206-1 compacted so as to retain no appreciable amount of entrapped air other than entrained air.

  • Standard
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day