Abstract

Scope of the proposed deliverable
To determine liquid flow, the following steps are necessary:
1) Measure water surface (or near surface) velocity with techniques using radar, laser or video images;
2) Adjust wind effects to the water surface velocity;
3) Translate the adjusted velocity to an averaged velocity by applying the velocity index or numerical computation;
4) Determine the area of the wetted cross section from the stage area relationship; and
5) Obtain water discharge by multiplying the averaged velocity by the wetted cross sectional area.
This procedure is applicable to different kinds of channel and river section.
Applications include:
•Rivers and streams;
•Artificial channels such as drainage ditches and irrigation channels;
•Wastewater flows discharging to sewer or the environment through channels or partially filled pipes;
•In sewer measurements;
•Process flows on wastewater treatment plants.
For any individual site the method to measure water surface velocity should be selected appropriately, based on the site conditions, nature of the application and uncertainty required. Take a special note
that non-contact methods should NOT be used where a tidal phenomenon is present.

Status
Not Published
Public Enquiry End Date
14-Jul-2026
Current Stage
4020 - Public enquire (PE) (Adopted Project)
Start Date
21-May-2026
Due Date
08-Oct-2026
Completion Date
15-Jul-2026

Buy Documents

Draft

oSIST prEN ISO 24577:2026

English language (23 pages)
Preview
Preview
e-Library read for
×1 day

oSIST prEN ISO 24577:2026 is the SIST draft adoption of ISO/DIS 24577:2026 for hydrometry. It specifies how to use noncontact methods - radar, laser Doppler radar, and video-based image velocimetry - to measure water surface velocity and determine discharge in open channels. The document is for practitioners who need discharge measurements from rivers, streams, artificial channels, sewer-related flows, and wastewater treatment plant process flows without placing sensors in the water.

What does oSIST prEN ISO 24577:2026 specify?

oSIST prEN ISO 24577:2026 specifies a measurement chain for determining liquid flow from water surface velocity. In practice, the document links surface-velocity measurement, wind correction, conversion to depth-averaged or cross-sectional velocity, stage-area determination, and discharge calculation.

The scope covers rivers and streams, artificial channels such as drainage ditches and irrigation channels, wastewater flows in channels or partially filled pipes, sewer measurements, and process flows on wastewater treatment plants. It also states that the method should be chosen for the site, the application, and the required uncertainty, and that noncontact methods should not be used where a tidal phenomenon is present.

The document is organized into these main parts:

  • Clause 1 - Scope
  • Clause 2 - Normative references
  • Clause 3 - Terms and definitions
  • Clause 4 - Non-contact measuring methods
  • Clause 5 - Fixed installations and temporary measurements
  • Clause 6 - Measurement strategies
  • Clause 7 - Computational methods
  • Clause 8 - Uncertainty

What are the key requirements of oSIST prEN ISO 24577:2026?

The central requirement in oSIST prEN ISO 24577:2026 is to measure water surface velocity with a noncontact technique, then turn that observation into discharge through a documented chain of corrections and calculations. The document is practical about this: if any step is weak, the final discharge value becomes less reliable.

Clause 4 - Choose an appropriate noncontact method

Clause 4 describes radar, laser Doppler radar, and image velocimetry as the main noncontact measuring methods. It also explains the limits of each method, such as sensitivity to wind, image quality, lighting, fog, and the fact that surface motion is not always identical to depth-averaged flow.

For readers, this means the method must match the site. A camera-based system may be useful where a bridge or bank gives a good view, while radar can be better where a sensor must remain above the water.

Clause 5 - Install the system so the geometry stays stable

Clause 5 says installations should be secure and rigid, should cover as much of the cross section as possible, and should avoid hazards, vandalism, and bed changes that can distort results. It also gives typical locations such as bridges, river banks, aircraft, drones, and satellites.

In practice, the site must let the instrument see the flow without being disturbed by movement, obstructions, or changing bed levels. The document also prefers long, straight reaches because they usually give a more stable velocity profile.

Clause 6 - Measure the supporting data, not only velocity

Clause 6 requires measurement strategies for sampling periods, wind, cross-section and cross-sectional profile, and water level. It stresses that wind speed and direction may need to be measured in real time, and that the cross-section and water level must support the velocity measurement at the same site or through a justified reference location.

For users, this means the velocity reading alone is not enough. The discharge calculation also needs a reliable stage-area relationship and a profile that reflects the actual wetted cross section.

Clause 7 - Use either arithmetic methods or the index velocity method

Clause 7 sets out two computational approaches. The arithmetic methods divide the cross section into segments and calculate discharge from segment velocity and area, while the index velocity method uses a rating between a representative index velocity and the mean channel velocity, together with the stage-area rating.

This matters because the choice of method affects how much field data you need and how the site is maintained. Arithmetic methods can be used across a wide range of water levels, while the index velocity method depends on a valid rating built from representative measurements.

Clause 7 - Correct for wind and water-surface geometry

Clause 7 also covers wind correction and stage-area determination. Wind can accelerate or slow the water surface velocity field, so the observed value may need correction before it is converted to discharge. The stage-area relationship must reflect the wetted area at the measurement stage.

For field work, this means the operator must not treat the sensor output as the final answer. The measurement needs site-specific geometry and wind treatment before it becomes a discharge value.

Clause 8 - Evaluate uncertainty explicitly

Clause 8 ties the document to hydrometric uncertainty practice and requires the main uncertainty sources to be considered. These include bed evolution, surface-velocity measurement error, image preprocessing and orthorectification, and uncertainty in the velocity-conversion factor.

In practice, this tells the reader to quantify uncertainty from the start, not after the campaign. It is especially important where the bed can change during floods or where image-based methods need geometric correction.

What terms does oSIST prEN ISO 24577:2026 define?

oSIST prEN ISO 24577:2026 uses the terms and definitions from ISO 772:2022 and ISO 748:2021. A few key terms are central to the document:

  • Water surface velocity - the velocity measured at or near the water surface before any conversion to a depth-averaged value.
  • Stage-area relationship - the relationship used to determine wetted cross-sectional area from water level.
  • Arithmetic methods - segment-based velocity-area methods used to calculate discharge from velocity and area.
  • Index velocity method - a method that relates measured index velocity to mean channel velocity and combines it with stage-area information.
  • Ground Control Points (GCP) - surveyed reference points used to transform image measurements into real-world coordinates.
  • Large Scale Particle Image Velocimetry (LSPIV) - an image velocimetry method that matches surface patterns between successive images.
  • Space Time Image Velocimetry (STIV) - an image method that tracks visible structures along a search line in a space-time image.

Who uses oSIST prEN ISO 24577:2026?

oSIST prEN ISO 24577:2026 is used by hydrometrists, river-gauging operators, wastewater engineers, and organizations that monitor open-channel flow. It is relevant to water authorities, utilities, environmental monitoring teams, and operators of treatment plants and sewer systems.

It also matters to people selecting or installing noncontact sensors on bridges, banks, temporary field sites, drones, aircraft, or satellites. Buyers and quality managers use it to judge whether a system can support safe field work, defensible discharge data, and site-specific uncertainty control.

Which standards are used with oSIST prEN ISO 24577:2026?

oSIST prEN ISO 24577:2026 refers to these documents:

  • ISO 748:2021 - the main reference for velocity-area methods and uncertainty ideas that are adapted here to surface-velocity measurements.
  • ISO 772:2022 - the vocabulary and symbols source for terms and definitions.
  • ISO 4373 - guidance for water level measuring devices.
  • ISO 15769:2010 - guidance used for the index velocity uncertainty approach.
  • ISO 25377 - hydrometric uncertainty guidance (HUG), used for the uncertainty framework.
  • NI GL 100.11-2021 - an Australian guideline cited for surface-velocity applications and segment selection.

What does the oSIST prEN ISO 24577:2026 document contain?

The document contains method descriptions for radar, laser Doppler radar, and image velocimetry, including LSPIV, SSIV, PTV, and STIV. It explains where and how these methods are mounted, such as on bridges, river banks, aircraft, drones, and satellites.

It also includes measurement strategy guidance for sampling, wind, cross-section profiling, and water-level measurement. The computational part covers segment-based calculations, wind correction, stage-area ratings, and the index velocity method.

Clause 8 adds uncertainty treatment and worked calculation examples for both the arithmetic method and the index velocity method. The bibliography then points to related hydrometry, uncertainty, radar, and image-velocimetry literature.

Buy Documents

Draft

oSIST prEN ISO 24577:2026

English language (23 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

BSMI (Bureau of Standards, Metrology and Inspection)

Taiwan's standards and inspection authority.

TAF Taiwan Verified

Sponsored listings

Frequently Asked Questions

oSIST prEN ISO 24577:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Hydrometry - Use of noncontact methods for measuring water surface velocity and determining discharge (ISO/DIS 24577:2026)". This standard covers: Scope of the proposed deliverable To determine liquid flow, the following steps are necessary: 1) Measure water surface (or near surface) velocity with techniques using radar, laser or video images; 2) Adjust wind effects to the water surface velocity; 3) Translate the adjusted velocity to an averaged velocity by applying the velocity index or numerical computation; 4) Determine the area of the wetted cross section from the stage area relationship; and 5) Obtain water discharge by multiplying the averaged velocity by the wetted cross sectional area. This procedure is applicable to different kinds of channel and river section. Applications include: •Rivers and streams; •Artificial channels such as drainage ditches and irrigation channels; •Wastewater flows discharging to sewer or the environment through channels or partially filled pipes; •In sewer measurements; •Process flows on wastewater treatment plants. For any individual site the method to measure water surface velocity should be selected appropriately, based on the site conditions, nature of the application and uncertainty required. Take a special note that non-contact methods should NOT be used where a tidal phenomenon is present.

Scope of the proposed deliverable To determine liquid flow, the following steps are necessary: 1) Measure water surface (or near surface) velocity with techniques using radar, laser or video images; 2) Adjust wind effects to the water surface velocity; 3) Translate the adjusted velocity to an averaged velocity by applying the velocity index or numerical computation; 4) Determine the area of the wetted cross section from the stage area relationship; and 5) Obtain water discharge by multiplying the averaged velocity by the wetted cross sectional area. This procedure is applicable to different kinds of channel and river section. Applications include: •Rivers and streams; •Artificial channels such as drainage ditches and irrigation channels; •Wastewater flows discharging to sewer or the environment through channels or partially filled pipes; •In sewer measurements; •Process flows on wastewater treatment plants. For any individual site the method to measure water surface velocity should be selected appropriately, based on the site conditions, nature of the application and uncertainty required. Take a special note that non-contact methods should NOT be used where a tidal phenomenon is present.

oSIST prEN ISO 24577:2026 is classified under the following ICS (International Classification for Standards) categories: 07.060 - Geology. Meteorology. Hydrology; 17.120.20 - Flow in open channels. The ICS classification helps identify the subject area and facilitates finding related standards.

oSIST prEN ISO 24577:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Non-contact measuring methods
  • 4.1 General
  • 4.2 Surface velocity radar
  • 4.3 Laser Doppler radar
  • 4.4 Image velocimetry
  • 5 Fixed installations and temporary measurements
  • 5.1 General
  • 5.2 Bridge
  • 5.3 River or channel bank
  • 5.4 Aircraft, drones and satellites
  • 6 Measurement strategies
  • 6.1 Sampling periods
  • 6.2 Wind measurements
  • 6.3 Cross-section and cross-sectional profile measurements
  • 6.4 Water-level measurement
  • 7 Computational methods
  • 7.1 General
  • 7.2 Arithmetic methods (or velocity area methods)
  • 7.3 Wind correction
  • 7.4 Stage-area determinations
  • 1. The Standard Cross Section
  • 2. Survey the standard cross section
  • 3. Develop stage-area rating
  • 7.5 Index velocity method
  • 8 Uncertainty
  • 8.1 Application of uncertainty methods for arithmetic and index-velocity methods
  • 8.2 Uncertainty of the arithmetic method
  • 8.3 Uncertainty of the index velocity method
  • 8.4 Other uncertainty estimation methods
  • Bibliography

Introduction

This document presents non-contact techniques for measuring water surface velocity and liquid flow in open channels. Water surface velocity can be measured with different technologies, such as radar or video images and then to be converted into discharge. These methods can be used either in the form of permanent installations at a gauge or as episodic measurements requiring human labor in actual field measurements. Especially for the episodic case the advantage of all non-contact types consists in including a safe distance from the water and thus serves to increase the safety of staff. Because of the availability of different measurement techniques, the user needs to select the most appropriate system in terms of site conditions, such as type of flow field, width of the channel or river, and installation conditions. To obtain discharge, the cross-sectional area of the flow field is also required. To estimate the cross-sectional area, the channel cross-sectional profile as well as water level should be measured. Whilst not covered explicitly in this Standard, care should also be taken in selection of the most appropriate bottom topography and water level measurement for the site conditions. For river flows, water surface and river flow conditions during target flood stages are key factors in selecting systems.

The structure of the following chapters reflects the typical order of any installation in practice, first acquiring the data which means choosing the method and installing the instruments. Gathering the first data will perhaps refine or redefine the measurement strategy. Then computational methods will be applied or improved. Finally regarding and reducing the uncertainties is an important consideration in order to provide quality-assured data from that measuring site.

The non-contact techniques for measuring water surface velocity are undergoing constant development. Therefore, this document can only aim to show the basic principles and their possibilities and limitations; a complete overview of all methods is not possible due to the dynamics in this area.

oSIST prEN ISO 24577:2026

oSIST prEN ISO 24577:2026 DRAFT International Standard ISO/DIS 24577:2026(en) Hydrometry — Use of noncontact methods for measuring water surface velocity and determining discharge

1 Scope

To determine liquid flow, the following steps are necessary:

1) Measure water surface velocity with techniques using radar, laser or video images; 2) Correct the water surface velocity due to wind effects if necessary; 3) Option a: Transform the corrected velocity to a depth-averaged velocity in one segment using the arithmetic methods referring to chapter 7.2, secondly calculate each segment and then create the sum of all segments to obtain the cross-sectional averaged velocity distribution; 3) Option b: Transform the corrected velocity to a cross sectional velocity using the index methods referring to chapter 7.3; 4) Determine the area of the wetted cross section from the stage-area relationship; 5) Obtain discharge of each segment by multiplying the depth-averaged velocity in each segment by the wetted cross-sectional area of each segment. And then create the sum of all segments to obtain whole discharge in cross section.

This procedure is applicable to different kinds of channel and river sections. Applications include:

  • Rivers and streams;
  • Artificial channels such as drainage ditches and irrigation channels;
  • Process flows on wastewater treatment plants.

For any individual site the method to measure water surface velocity should be selected appropriately, based on the site conditions, nature of the application and uncertainty required. Take a special note that noncontact methods should not be used where a unique relation between surface velocity and depth averaged velocity cannot be established, e.g. where tidal phenomena are present. This is caused by the variations of flow magnitude and direction over depth being highly variable over time under these circumstances. Regarding backwater zones or in the vicinity of obstacles the relation between surface velocity and depth averaged velocity may be more complicated, but even here optical methods may be helpful to at least learn the situation at the surface.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 748:2021, Hydrometry — Measurement of liquid flow in open channels — Velocity area methods using point velocity measurements ISO 772:2022, Hydrometry — Vocabulary and symbols ISO 4373, Hydrometry — Water level measuring devices

oSIST prEN ISO 24577:2026 ISO/DIS 24577:2026(en) ISO 15769:2010, Hydrometry — Guidelines for the application of acoustic velocity meters using the Doppler and echo correlation methods ISO 25377, Hydrometric uncertainty guidance (HUG) National Industry Guidelines for hydrometric monitoring, Part 11: Application of surface velocity methods for velocity and open channel discharge measurements, NI GL 100.11-2021; Australian Government, Bureau of Meteorology

3 Terms and definitions

For the purposes of this document, the terms and definitions given in ISO 772:2022 and ISO 748:2021 apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https:// www .iso .org/ obp
  • IEC Electropedia: available at https:// www .electropedia .org/

4 Non-contact measuring methods

4.1 General

Obtaining liquid flow requires the determination of the following components: measured flow, the crosssectional averaged velocity derived using different methods and the flow area. Non-contact measuring equipment is used to determine water surface velocity. For non-contact flow measurement, different types of equipment with different principles can be employed, including radar, laser and video images. In particular, image velocimetry measures the travel velocity of tracer materials or visible water surface structures on the water surface and surface waves. We generally assume that the travel velocity of water surface tracers or visible water surface structures is equivalent to water surface velocity, which is not always true. In that case we should try to correct for the mismatch or at least be aware that our assumption might not be true. Flow area is deduced from measurement of the water level, or stage, and knowledge of the channel profile. Non-contact techniques such as radar, ultrasonic level measurement or other water level sensors including the optical devices themselves are used to measure the water level. In some systems, the water level sensor is integrated within the body which also houses the velocity sensor. The velocity and level sensors will be connected to an electronics unit, which may be separate or integrated within the same housing. This will perform some or all of the following functions:

  • Provide power to the system;
  • Provide temperature and humidity controlled system;
  • Record measurements;
  • Interpret the signal returned by the sensors to determine measured surface velocity and water level;
  • Compute the mean velocity from the measured velocity from a pre-established relationship;
  • Compute the volumetric flow;
  • Generate an output to a data logger or telemetry system;
  • Provide a visual display of the measured and or computed values;
  • Provide a user interface to programme and commission the system;
  • Provide security devices.

oSIST prEN ISO 24577:2026 ISO/DIS 24577:2026(en) With some experimental or survey systems, these functions may be incorporated in software loaded onto a measuring device.

4.1.1 Advantages and benefits

In most situations installation and maintenance can be completed without personnel needing to enter the water or channel. This is beneficial in terms of health and safety by reducing the risk to staff. Non-contact measurement methods have these benefits:

  • In case of a video-based method you record a lot of the measured environment.
  • As the sensor does not come in contact with the water, there is less risk of damaging, contamination and fouling of the sensors, particularly in wastewater and other applications where contaminants may be present.
  • Number of visiting personnel to measurement site is nothing or less than ordinary method.
  • Using non-contact type which can obtain discharge value in real time, the flow discharge can be constantly monitored without creating a regular rating curve with stage/discharge.
  • Creating a regular rating curve with stage/discharge has many benefits, such as being able to determine the flow rate from the water level if the non-contact type breaks (a fail-safe function) and being able to understand the hydraulic characteristics of the observation station and use them in analysis. Although the non-contact method can be a good complement if the rating curve is unreliable.
4.1.2 Limitations
  • Depending on the method you may only record a small part of the surface.
  • A relationship between the surface velocity and the depth averaged or cross-sectionally averaged velocity is needed.
  • Surface velocity methods are sensitive to wind and vegetation effects.
  • Image conditions can be affected by a number of environmental factors, these are heavy rainfall, heavy snowfall and most of all fog. However, measurements in these situations can reliably be filtered out, e.g. through comparison with learned surface velocity profiles, Peña-Haro et al. Also glare and reflection can influence the measurements, but typically this is not significant.
  • In the case of thermal infrared cameras, the uniformity of surface temperature can also pose a challenge.
  • The bottom topography is not measured simultaneously, referring to erosion and or sedimentation.

4.2 Surface velocity radar

Throughout the document the device called radar is a surface velocity radar or it is explicitly stated that it is about a radar only measuring the water level or stage.

Radar stands for "RAdio Detection And Ranging". Radar techniques use the Doppler effect to measure water surface velocity by observing the frequency difference between the transmitted and received electromagnetic beams. Radar measurement can be classified into two types: surface measurement, in which electromagnetic beams are emitted over a wide area to obtain a two-dimensional velocity field, and point measurement, in which beams are emitted to a limited illuminated area to obtain velocity values at the point. Both of them basically observe velocity component along the beam direction. To obtain velocity on the water surface, geometrical conversion, such as the depression angles of the device, should be carried out. With a surface velocity radar you measure the surface velocity at a certain area. In case of homogenous flow, this, a single point measurement, is sufficient to calculate the flow discharge. Even mobile or portable radar solutions produce precise results.

oSIST prEN ISO 24577:2026 ISO/DIS 24577:2026(en)

4.3 Laser Doppler radar

Laser Doppler radar instruments focus a beam of light from a laser which is mounted above the flow at a specific point. The frequency difference of the transmitted and reflected light gives the velocity at the point of measurement. The laser can be focussed at a precise point in the flow field; it can also penetrate the liquid surface. In this way, a single laser can be used to scan both across the flow field horizontally and, to a degree which depends on the turbidity of the water, through the depth. This enables the mean fluid velocity to be estimated over a range of flow conditions.

4.4 Image velocimetry

Image velocimetry is a technique using images continuously filmed with video or a camera. Three methods are practiced at present and more evolving such as SSIV. The cross-correlation techniques Large Scale Particle Image Velocimetry (LSPIV) and Surface Structure Image Velocimetry (SSIV) determine the velocity vector by matching water surface patterns of particle constellations or surface structures between two images obtained at different time points.

The Particle Tracking Velocimetry (PTV) tracks a tracer and the Space Time Image Velocimetry (STIV) monitors the movement of natural tracers, structures or water surface waves to determine the velocity component.

Whichever velocimetry algorithm is used, the image filtering is crucial to separate surface velocity signal from artefacts such as shapes, standing waves or other objects not representing actual surface velocity. That is the case for prefiltering processes but also for postprocessing velocity results. Infrared cameras and high sensitivity cameras or a proper illumination are available for 24-hour operation. Aside from experimental studies, image conversion may be necessary when these techniques are applied to actual flows. For example, in the case of the video images obtained from the river or channel bank with small angles to horizontal and from a bridge or from the air with large angle to horizontal, images should be converted with the explicit orthorectification method.

Installation / location-survey of rating points are necessary to conduct successful measurements with good accuracy. Ground Control Points (GCP) need to be installed or specified, measured in X, Y, Z and defined in the camera view. GCPs should be widely distributed in X, Y, and Z directions, the more GCPs are used the more accurate. If also the camera position is measured, two GCPs and a visible shoreline are the minimum conditions for the image transformation method. On the other hand, image conversion is possible even without GCPs if the camera position and angle, lens constant and water surface height are known.

4.4.1 Cross correlation techniques LSPIV and SSIV

The Large Scale Particle Image Velocimetry (LSPIV) and Surface Structure Image Velocimetry (SSIV) are velocity measurement techniques designed to detect and track persistent and congruent patterns and surface structures from one image to the next in a time series of images, on the assumption that the similar visual patterns in different locations are the results of the movement of water surface tracers or surface waves. It can determine the velocity vector in stream and spanwise directions. Pattern detection can be conducted by searching the filmed area with changing the size of the target pattern or structure as well as a searching area. It is recommended to use a high-resolution video camera capable of taking either 24 fps (PAL) or 30 fps (NTSC) or more. Both methods can be conducted without adding or injecting tracers under good conditions. It can be used to measure water discharge and flow field. In general, the size of the targeted pattern has similar size in entire section, though ratio of the resolution of camera to the pattern is not constant in one image.

Therefore, the measurement accuracy of this technique depends on the distance from the camera to the target point and angle from camera to the flow direction, i.e. on the resolution of pixels per pattern or structure size. The feasibility and accuracy of the analysis also depend on the clarity of the structure (pattern) on the water surface, which is determined by factors such as the way the light hits it.

oSIST prEN ISO 24577:2026 ISO/DIS 24577:2026(en)

4.4.2 PTV

The Particle Tracking Velocimetry (PTV) is a velocity measurement technique designed to determine the velocity vector by tracking identical objects between subsequent images. Usually, tracers that are purposefully distributed in the area of measurement are used as trackable objects, but visible material, e.g., debris, driftwood, or anything that moves by water flow, can also work as tracers, when present on the water surface. It is not generally true however, that the movement of water surface and the movement of the tracer are identical because the latter is affected by how much portion of the tracer is under the water. Similar to LSPIV and SSIV, it is capable of both water discharge measurement and flow field measurement. In principle the measurement accuracy of this technique depends on the distance from the camera to the target point and angle from the camera to the flow direction.

4.4.3 STIV

The Space Time Image Velocimetry (STIV) is a velocity measurement technique designed to track the movement of water surface patterns or visible structures on the water surface along a search line. Search lines are set in the flow direction to determine flow discharge and must be perpendicular to the reference cross-section. The image along each search line is converted to a space and time image of which vertical and horizontal axes represent time and space, respectively. If the flow is steady a space and time image usually shows several straight lines (unless they are accelerating), each of which indicates the movement of an object or structure along the line with respect to time.

The angle of each line indicates the speed of an object or structure. It is recommended to use a high-resolution video camera capable of taking 30 frames per second. as standard, at least 7,5 frames per second. Space and time image is applicable to anything visible on the water surface whose movement can be translated into a space and time image. Unlike to the LSPIV and SSIV, which correlate spatial patterns in time, the STIV method depends on the visibility of objects and structures as they move downstream. For long distances with poor pixel resolution or very shallow angles (down to a few degrees to the horizontal), the correlation of a spatial pattern is more likely to be lost, as compared to the line of a visible object or structure traveling downstream along an inspection line. In this sense STIV is more suited for long distances and shallow inclination angles from the camera to the water surface. The STIV method has a small computational load and is easy to perform real-time observations. Even mobile or portable STIV solutions are also available.

5 Fixed installations and temporary measurements

5.1 General

One of the great advantages of non-contact current meters is flexible installation. Unlike contact methods, they can be installed in a variety of ways, depending on the operators' intention as well as the conditions of the measurement section. The description of this chapter includes both, fixed and temporary measurement. Although several patterns of installation are possible, the options should be carefully considered in terms of the performance of each device. For all kind of installations, the following should be considered:

...