prEN ISO 24577
(Main)Hydrometry – Use of noncontact methods for measuring water surface velocity and determining discharge (ISO/DIS 24577:2026)
- Abstract
Scope of the proposed deliverable
To determine liquid flow, the following steps are necessary:
1) Measure water surface (or near surface) velocity with techniques using radar, laser or video images;
2) Adjust wind effects to the water surface velocity;
3) Translate the adjusted velocity to an averaged velocity by applying the velocity index or numerical computation;
4) Determine the area of the wetted cross section from the stage area relationship; and
5) Obtain water discharge by multiplying the averaged velocity by the wetted cross sectional area.
This procedure is applicable to different kinds of channel and river section.
Applications include:
•Rivers and streams;
•Artificial channels such as drainage ditches and irrigation channels;
•Wastewater flows discharging to sewer or the environment through channels or partially filled pipes;
•In sewer measurements;
•Process flows on wastewater treatment plants.
For any individual site the method to measure water surface velocity should be selected appropriately, based on the site conditions, nature of the application and uncertainty required. Take a special note
that non-contact methods should NOT be used where a tidal phenomenon is present.
- Status
- Not Published
- Publication Date
- 19-Oct-2027
- Technical Committee
- CEN/TC 318 - Hydrometry
- Drafting Committee
- CEN/TC 318 - Hydrometry
- Current Stage
- 4060 - Closure of enquiry - Enquiry
- Start Date
- 23-Jul-2026
- Due Date
- 13-Jun-2027
- Completion Date
- 13-Jun-2027
prEN ISO 24577 is a proposed CEN standard for hydrometry. It specifies how to measure water surface velocity without contact, correct for wind effects, convert the result to an averaged velocity, and combine it with wetted cross-sectional area to determine discharge in open channels. It is meant for engineers and operators who need discharge measurements in rivers, channels, sewers, wastewater works, and similar sites.
What does prEN ISO 24577 specify?
prEN ISO 24577 covers the use of non-contact methods for measuring water surface velocity and determining discharge. The document describes the measurement chain from sensing the surface flow to calculating discharge, and it warns that the method depends on site conditions and the uncertainty required.
The procedure applies to rivers and streams, artificial channels, wastewater flows in channels or partially filled pipes, sewer measurements, and process flows on wastewater treatment plants. It also states that non-contact methods should not be used where tidal phenomena are present.
The document is organized into eight clauses plus a bibliography.
| Clause | What it covers |
|---|---|
| 1 | Scope and applicability |
| 2 | Normative references |
| 3 | Terms and definitions |
| 4 | Non-contact measuring methods |
| 5 | Fixed installations and temporary measurements |
| 6 | Measurement strategies |
| 7 | Computational methods |
| 8 | Uncertainty |
What are the key requirements of prEN ISO 24577?
prEN ISO 24577 sets out a practical sequence for turning surface measurements into discharge. In practice, the user must choose a suitable sensing method, gather enough geometric data, apply the right computational approach, and check the uncertainty before relying on the result.
Measure surface velocity, then convert it to discharge
Clause 1 starts with measuring water surface velocity using radar, laser, or video images. The measured surface velocity is then corrected for wind if necessary, converted to an averaged velocity, combined with wetted cross-sectional area from the stage-area relationship, and used to calculate discharge.
This matters because the standard does not treat the surface reading as the final answer. The reader has to build a complete discharge calculation, not just a velocity measurement.
Choose the method to fit the site
Clause 1 says the method for measuring water surface velocity should be selected for the site conditions, the application, and the uncertainty required. The document also warns against using non-contact methods where a unique relation between surface velocity and depth-averaged velocity cannot be established, for example in tidal situations.
In practice, this means the same sensor may work well at one site and poorly at another. Site selection is part of the measurement system, not an afterthought.
Use one of the non-contact measurement families in Clause 4
Clause 4 describes three families of methods: surface velocity radar, laser Doppler radar, and image velocimetry. Image velocimetry includes Large Scale Particle Image Velocimetry (LSPIV), Surface Structure Image Velocimetry (SSIV), Particle Tracking Velocimetry (PTV), and Space Time Image Velocimetry (STIV).
This matters because each method has different strengths. Radar and laser systems suit some fixed installations, while image methods can capture more of the visible flow field but depend heavily on image quality and geometry.
Install and aim the sensors correctly
Clause 5 covers fixed installations and temporary measurements at bridges, river or channel banks, aircraft, drones, and satellites. It emphasizes secure mounting, enough coverage of the cross-section, and suitable viewing angles for optical sensors.
The practical point is that a good sensor can still give poor results if the mounting is unstable, the view is obstructed, or the camera angle is unsuitable. Clause 5 is about making the measurement repeatable.
Control sampling, wind, cross-section, and water level
Clause 6 covers sampling periods, wind measurements, cross-section and cross-sectional profile measurements, and water-level measurement. It explains that sampling may need to be long enough to average turbulence and vibration, or repeated in shorter samples and ensemble-averaged.
The document also requires wind speed and direction measurements when wind affects the surface field, and it links discharge to a proper stage-area relationship and a reliable water-level gauge. For the reader, this means the flow result depends on more than the velocity sensor alone.
Use either arithmetic methods or the index velocity method
Clause 7 identifies two main computational approaches: arithmetic methods, also called velocity area methods, and the index velocity method. The arithmetic approach divides the cross-section into segments and sums the segment discharges. The index velocity method uses a rating between measured index velocity and mean channel velocity together with a stage-area rating.
This is a key choice. Arithmetic methods are more directly tied to the measured surface velocity, while the index velocity method depends on established ratings and periodic verification.
Account for uncertainty explicitly
Clause 8 applies uncertainty concepts from the GUM, ISO 25377, ISO 748, and ISO 15769. It highlights special uncertainty sources for surface-velocity discharge measurements, including bed evolution, the performance of the velocity sensor, image preprocessing and orthorectification, and the uncertainty of the coefficient used to convert surface velocity to depth-averaged or section-averaged velocity.
In practice, the standard expects the user to treat uncertainty as part of the measurement result. That is important for data acceptance, calibration, and comparison between stations or methods.
What terms does prEN ISO 24577 define?
prEN ISO 24577 uses terms from ISO 772:2022 and ISO 748:2021, and several key terms are central to its method.
- Water surface velocity - the velocity measured at or near the water surface, which is the starting point for discharge determination.
- Stage-area relationship - the relationship between water level and wetted cross-sectional area used to convert stage into area.
- Arithmetic methods - segmented velocity-area methods that convert surface velocity into discharge by summing segment values.
- Index velocity method - a method that derives discharge from an index velocity rating and a stage-area rating.
- Ground Control Points (GCP) - surveyed reference points used to transform camera images into real-world coordinates.
- Orthorectification - image conversion that corrects viewing geometry so the image can be used for measurement.
- Large Scale Particle Image Velocimetry (LSPIV) - a cross-correlation image method that tracks surface patterns between images.
- Space Time Image Velocimetry (STIV) - an image method that converts a line in the scene into a space-time image to estimate velocity.
Who uses prEN ISO 24577?
prEN ISO 24577 is used by hydrometry specialists, river gauging staff, wastewater plant operators, and engineers who design or verify discharge monitoring systems. It is also relevant to quality managers and buyers who need to judge whether a non-contact method fits the site and the uncertainty target.
The applications named in the document include rivers and streams, drainage ditches, irrigation channels, wastewater flows in channels or partially filled pipes, sewer measurements, and process flows on wastewater treatment plants. In practice, users apply it for site surveys, sensor installation, discharge computation, calibration, verification, and uncertainty evaluation.
Which standards are used with prEN ISO 24577?
prEN ISO 24577 refers to several documents that support its method:
- ISO 748:2021 - provides the velocity area methods basis and uncertainty treatment for open-channel liquid flow measurement.
- ISO 772:2022 - supplies the vocabulary and symbols used for hydrometry terms.
- ISO 4373 - supports water level measuring devices.
- ISO 15769:2010 - supports acoustic velocity meter guidance and the uncertainty treatment for the index velocity method.
- ISO 25377 - provides hydrometric uncertainty guidance (HUG).
- NI GL 100.11-2021 - gives Australian guidance for surface velocity methods in open channel discharge measurements.
What does the prEN ISO 24577 document contain?
prEN ISO 24577 contains descriptions of radar, laser Doppler radar, and image velocimetry methods, including LSPIV, SSIV, PTV, and STIV. It also explains installation options for bridges, banks, aircraft, drones, and satellites, together with the practical constraints that affect image and radar measurements.
The document includes guidance on sampling periods, wind measurements, cross-section survey needs, and water-level measurement. It then develops the arithmetic and index velocity calculation paths, including segment choice, the surface-to-mean velocity coefficient, wind correction, stage-area determination, and rating development.
Clause 8 contains uncertainty treatment for both computational routes and shows how the standard adapts the general uncertainty framework to surface-velocity-based discharge measurements. The bibliography points readers to related hydrometry, image velocimetry, and uncertainty references that support implementation and verification.
Get Certified
Connect with accredited certification bodies for this standard
BSMI (Bureau of Standards, Metrology and Inspection)
Taiwan's standards and inspection authority.
Sponsored listings
Frequently Asked Questions
prEN ISO 24577 is a draft published by the European Committee for Standardization (CEN). Its full title is "Hydrometry – Use of noncontact methods for measuring water surface velocity and determining discharge (ISO/DIS 24577:2026)". This standard covers: Scope of the proposed deliverable To determine liquid flow, the following steps are necessary: 1) Measure water surface (or near surface) velocity with techniques using radar, laser or video images; 2) Adjust wind effects to the water surface velocity; 3) Translate the adjusted velocity to an averaged velocity by applying the velocity index or numerical computation; 4) Determine the area of the wetted cross section from the stage area relationship; and 5) Obtain water discharge by multiplying the averaged velocity by the wetted cross sectional area. This procedure is applicable to different kinds of channel and river section. Applications include: •Rivers and streams; •Artificial channels such as drainage ditches and irrigation channels; •Wastewater flows discharging to sewer or the environment through channels or partially filled pipes; •In sewer measurements; •Process flows on wastewater treatment plants. For any individual site the method to measure water surface velocity should be selected appropriately, based on the site conditions, nature of the application and uncertainty required. Take a special note that non-contact methods should NOT be used where a tidal phenomenon is present.
Scope of the proposed deliverable To determine liquid flow, the following steps are necessary: 1) Measure water surface (or near surface) velocity with techniques using radar, laser or video images; 2) Adjust wind effects to the water surface velocity; 3) Translate the adjusted velocity to an averaged velocity by applying the velocity index or numerical computation; 4) Determine the area of the wetted cross section from the stage area relationship; and 5) Obtain water discharge by multiplying the averaged velocity by the wetted cross sectional area. This procedure is applicable to different kinds of channel and river section. Applications include: •Rivers and streams; •Artificial channels such as drainage ditches and irrigation channels; •Wastewater flows discharging to sewer or the environment through channels or partially filled pipes; •In sewer measurements; •Process flows on wastewater treatment plants. For any individual site the method to measure water surface velocity should be selected appropriately, based on the site conditions, nature of the application and uncertainty required. Take a special note that non-contact methods should NOT be used where a tidal phenomenon is present.
prEN ISO 24577 is classified under the following ICS (International Classification for Standards) categories: 07.060 - Geology. Meteorology. Hydrology; 17.120.20 - Flow in open channels. The ICS classification helps identify the subject area and facilitates finding related standards.
prEN ISO 24577 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Non-contact measuring methods
- 4.1 General
- 4.2 Surface velocity radar
- 4.3 Laser Doppler radar
- 4.4 Image velocimetry
- 5 Fixed installations and temporary measurements
- 5.1 General
- 5.2 Bridge
- 5.3 River or channel bank
- 5.4 Aircraft, drones and satellites
- 6 Measurement strategies
- 6.1 Sampling periods
- 6.2 Wind measurements
- 6.3 Cross-section and cross-sectional profile measurements
- 6.4 Water-level measurement
- 7 Computational methods
- 7.1 General
- 7.2 Arithmetic methods (or velocity area methods)
- 7.3 Wind correction
- 7.4 Stage-area determinations
- 1. The Standard Cross Section
- 2. Survey the standard cross section
- 3. Develop stage-area rating
- 7.5 Index velocity method
- 8 Uncertainty
- 8.1 Application of uncertainty methods for arithmetic and index-velocity methods
- 8.2 Uncertainty of the arithmetic method
- 8.3 Uncertainty of the index velocity method
- 8.4 Other uncertainty estimation methods
- Bibliography
Introduction
This document presents non-contact techniques for measuring water surface velocity and liquid flow in open channels. Water surface velocity can be measured with different technologies, such as radar or video images and then to be converted into discharge. These methods can be used either in the form of permanent installations at a gauge or as episodic measurements requiring human labor in actual field measurements. Especially for the episodic case the advantage of all non-contact types consists in including a safe distance from the water and thus serves to increase the safety of staff. Because of the availability of different measurement techniques, the user needs to select the most appropriate system in terms of site conditions, such as type of flow field, width of the channel or river, and installation conditions. To obtain discharge, the cross-sectional area of the flow field is also required. To estimate the cross-sectional area, the channel cross-sectional profile as well as water level should be measured. Whilst not covered explicitly in this Standard, care should also be taken in selection of the most appropriate bottom topography and water level measurement for the site conditions. For river flows, water surface and river flow conditions during target flood stages are key factors in selecting systems.
The structure of the following chapters reflects the typical order of any installation in practice, first acquiring the data which means choosing the method and installing the instruments. Gathering the first data will perhaps refine or redefine the measurement strategy. Then computational methods will be applied or improved. Finally regarding and reducing the uncertainties is an important consideration in order to provide quality-assured data from that measuring site.
The non-contact techniques for measuring water surface velocity are undergoing constant development. Therefore, this document can only aim to show the basic principles and their possibilities and limitations; a complete overview of all methods is not possible due to the dynamics in this area.
oSIST prEN ISO 24577:2026
oSIST prEN ISO 24577:2026 DRAFT International Standard ISO/DIS 24577:2026(en) Hydrometry — Use of noncontact methods for measuring water surface velocity and determining discharge
1 Scope
To determine liquid flow, the following steps are necessary:
1) Measure water surface velocity with techniques using radar, laser or video images; 2) Correct the water surface velocity due to wind effects if necessary; 3) Option a: Transform the corrected velocity to a depth-averaged velocity in one segment using the arithmetic methods referring to chapter 7.2, secondly calculate each segment and then create the sum of all segments to obtain the cross-sectional averaged velocity distribution; 3) Option b: Transform the corrected velocity to a cross sectional velocity using the index methods referring to chapter 7.3; 4) Determine the area of the wetted cross section from the stage-area relationship; 5) Obtain discharge of each segment by multiplying the depth-averaged velocity in each segment by the wetted cross-sectional area of each segment. And then create the sum of all segments to obtain whole discharge in cross section.
This procedure is applicable to different kinds of channel and river sections. Applications include:
- Rivers and streams;
- Artificial channels such as drainage ditches and irrigation channels;
- Process flows on wastewater treatment plants.
For any individual site the method to measure water surface velocity should be selected appropriately, based on the site conditions, nature of the application and uncertainty required. Take a special note that noncontact methods should not be used where a unique relation between surface velocity and depth averaged velocity cannot be established, e.g. where tidal phenomena are present. This is caused by the variations of flow magnitude and direction over depth being highly variable over time under these circumstances. Regarding backwater zones or in the vicinity of obstacles the relation between surface velocity and depth averaged velocity may be more complicated, but even here optical methods may be helpful to at least learn the situation at the surface.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 748:2021, Hydrometry — Measurement of liquid flow in open channels — Velocity area methods using point velocity measurements ISO 772:2022, Hydrometry — Vocabulary and symbols ISO 4373, Hydrometry — Water level measuring devices
oSIST prEN ISO 24577:2026 ISO/DIS 24577:2026(en) ISO 15769:2010, Hydrometry — Guidelines for the application of acoustic velocity meters using the Doppler and echo correlation methods ISO 25377, Hydrometric uncertainty guidance (HUG) National Industry Guidelines for hydrometric monitoring, Part 11: Application of surface velocity methods for velocity and open channel discharge measurements, NI GL 100.11-2021; Australian Government, Bureau of Meteorology
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 772:2022 and ISO 748:2021 apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at https:// www .electropedia .org/
4 Non-contact measuring methods
4.1 General
Obtaining liquid flow requires the determination of the following components: measured flow, the crosssectional averaged velocity derived using different methods and the flow area. Non-contact measuring equipment is used to determine water surface velocity. For non-contact flow measurement, different types of equipment with different principles can be employed, including radar, laser and video images. In particular, image velocimetry measures the travel velocity of tracer materials or visible water surface structures on the water surface and surface waves. We generally assume that the travel velocity of water surface tracers or visible water surface structures is equivalent to water surface velocity, which is not always true. In that case we should try to correct for the mismatch or at least be aware that our assumption might not be true. Flow area is deduced from measurement of the water level, or stage, and knowledge of the channel profile. Non-contact techniques such as radar, ultrasonic level measurement or other water level sensors including the optical devices themselves are used to measure the water level. In some systems, the water level sensor is integrated within the body which also houses the velocity sensor. The velocity and level sensors will be connected to an electronics unit, which may be separate or integrated within the same housing. This will perform some or all of the following functions:
- Provide power to the system;
- Provide temperature and humidity controlled system;
- Record measurements;
- Interpret the signal returned by the sensors to determine measured surface velocity and water level;
- Compute the mean velocity from the measured velocity from a pre-established relationship;
- Compute the volumetric flow;
- Generate an output to a data logger or telemetry system;
- Provide a visual display of the measured and or computed values;
- Provide a user interface to programme and commission the system;
- Provide security devices.
oSIST prEN ISO 24577:2026 ISO/DIS 24577:2026(en) With some experimental or survey systems, these functions may be incorporated in software loaded onto a measuring device.
4.1.1 Advantages and benefits
In most situations installation and maintenance can be completed without personnel needing to enter the water or channel. This is beneficial in terms of health and safety by reducing the risk to staff. Non-contact measurement methods have these benefits:
- In case of a video-based method you record a lot of the measured environment.
- As the sensor does not come in contact with the water, there is less risk of damaging, contamination and fouling of the sensors, particularly in wastewater and other applications where contaminants may be present.
- Number of visiting personnel to measurement site is nothing or less than ordinary method.
- Using non-contact type which can obtain discharge value in real time, the flow discharge can be constantly monitored without creating a regular rating curve with stage/discharge.
- Creating a regular rating curve with stage/discharge has many benefits, such as being able to determine the flow rate from the water level if the non-contact type breaks (a fail-safe function) and being able to understand the hydraulic characteristics of the observation station and use them in analysis. Although the non-contact method can be a good complement if the rating curve is unreliable.
4.1.2 Limitations
- Depending on the method you may only record a small part of the surface.
- A relationship between the surface velocity and the depth averaged or cross-sectionally averaged velocity is needed.
- Surface velocity methods are sensitive to wind and vegetation effects.
- Image conditions can be affected by a number of environmental factors, these are heavy rainfall, heavy snowfall and most of all fog. However, measurements in these situations can reliably be filtered out, e.g. through comparison with learned surface velocity profiles, Peña-Haro et al. Also glare and reflection can influence the measurements, but typically this is not significant.
- In the case of thermal infrared cameras, the uniformity of surface temperature can also pose a challenge.
- The bottom topography is not measured simultaneously, referring to erosion and or sedimentation.
4.2 Surface velocity radar
Throughout the document the device called radar is a surface velocity radar or it is explicitly stated that it is about a radar only measuring the water level or stage.
Radar stands for "RAdio Detection And Ranging". Radar techniques use the Doppler effect to measure water surface velocity by observing the frequency difference between the transmitted and received electromagnetic beams. Radar measurement can be classified into two types: surface measurement, in which electromagnetic beams are emitted over a wide area to obtain a two-dimensional velocity field, and point measurement, in which beams are emitted to a limited illuminated area to obtain velocity values at the point. Both of them basically observe velocity component along the beam direction. To obtain velocity on the water surface, geometrical conversion, such as the depression angles of the device, should be carried out. With a surface velocity radar you measure the surface velocity at a certain area. In case of homogenous flow, this, a single point measurement, is sufficient to calculate the flow discharge. Even mobile or portable radar solutions produce precise results.
oSIST prEN ISO 24577:2026 ISO/DIS 24577:2026(en)
4.3 Laser Doppler radar
Laser Doppler radar instruments focus a beam of light from a laser which is mounted above the flow at a specific point. The frequency difference of the transmitted and reflected light gives the velocity at the point of measurement. The laser can be focussed at a precise point in the flow field; it can also penetrate the liquid surface. In this way, a single laser can be used to scan both across the flow field horizontally and, to a degree which depends on the turbidity of the water, through the depth. This enables the mean fluid velocity to be estimated over a range of flow conditions.
4.4 Image velocimetry
Image velocimetry is a technique using images continuously filmed with video or a camera. Three methods are practiced at present and more evolving such as SSIV. The cross-correlation techniques Large Scale Particle Image Velocimetry (LSPIV) and Surface Structure Image Velocimetry (SSIV) determine the velocity vector by matching water surface patterns of particle constellations or surface structures between two images obtained at different time points.
The Particle Tracking Velocimetry (PTV) tracks a tracer and the Space Time Image Velocimetry (STIV) monitors the movement of natural tracers, structures or water surface waves to determine the velocity component.
Whichever velocimetry algorithm is used, the image filtering is crucial to separate surface velocity signal from artefacts such as shapes, standing waves or other objects not representing actual surface velocity. That is the case for prefiltering processes but also for postprocessing velocity results. Infrared cameras and high sensitivity cameras or a proper illumination are available for 24-hour operation. Aside from experimental studies, image conversion may be necessary when these techniques are applied to actual flows. For example, in the case of the video images obtained from the river or channel bank with small angles to horizontal and from a bridge or from the air with large angle to horizontal, images should be converted with the explicit orthorectification method.
Installation / location-survey of rating points are necessary to conduct successful measurements with good accuracy. Ground Control Points (GCP) need to be installed or specified, measured in X, Y, Z and defined in the camera view. GCPs should be widely distributed in X, Y, and Z directions, the more GCPs are used the more accurate. If also the camera position is measured, two GCPs and a visible shoreline are the minimum conditions for the image transformation method. On the other hand, image conversion is possible even without GCPs if the camera position and angle, lens constant and water surface height are known.
4.4.1 Cross correlation techniques LSPIV and SSIV
The Large Scale Particle Image Velocimetry (LSPIV) and Surface Structure Image Velocimetry (SSIV) are velocity measurement techniques designed to detect and track persistent and congruent patterns and surface structures from one image to the next in a time series of images, on the assumption that the similar visual patterns in different locations are the results of the movement of water surface tracers or surface waves. It can determine the velocity vector in stream and spanwise directions. Pattern detection can be conducted by searching the filmed area with changing the size of the target pattern or structure as well as a searching area. It is recommended to use a high-resolution video camera capable of taking either 24 fps (PAL) or 30 fps (NTSC) or more. Both methods can be conducted without adding or injecting tracers under good conditions. It can be used to measure water discharge and flow field. In general, the size of the targeted pattern has similar size in entire section, though ratio of the resolution of camera to the pattern is not constant in one image.
Therefore, the measurement accuracy of this technique depends on the distance from the camera to the target point and angle from camera to the flow direction, i.e. on the resolution of pixels per pattern or structure size. The feasibility and accuracy of the analysis also depend on the clarity of the structure (pattern) on the water surface, which is determined by factors such as the way the light hits it.
oSIST prEN ISO 24577:2026 ISO/DIS 24577:2026(en)
4.4.2 PTV
The Particle Tracking Velocimetry (PTV) is a velocity measurement technique designed to determine the velocity vector by tracking identical objects between subsequent images. Usually, tracers that are purposefully distributed in the area of measurement are used as trackable objects, but visible material, e.g., debris, driftwood, or anything that moves by water flow, can also work as tracers, when present on the water surface. It is not generally true however, that the movement of water surface and the movement of the tracer are identical because the latter is affected by how much portion of the tracer is under the water. Similar to LSPIV and SSIV, it is capable of both water discharge measurement and flow field measurement. In principle the measurement accuracy of this technique depends on the distance from the camera to the target point and angle from the camera to the flow direction.
4.4.3 STIV
The Space Time Image Velocimetry (STIV) is a velocity measurement technique designed to track the movement of water surface patterns or visible structures on the water surface along a search line. Search lines are set in the flow direction to determine flow discharge and must be perpendicular to the reference cross-section. The image along each search line is converted to a space and time image of which vertical and horizontal axes represent time and space, respectively. If the flow is steady a space and time image usually shows several straight lines (unless they are accelerating), each of which indicates the movement of an object or structure along the line with respect to time.
The angle of each line indicates the speed of an object or structure. It is recommended to use a high-resolution video camera capable of taking 30 frames per second. as standard, at least 7,5 frames per second. Space and time image is applicable to anything visible on the water surface whose movement can be translated into a space and time image. Unlike to the LSPIV and SSIV, which correlate spatial patterns in time, the STIV method depends on the visibility of objects and structures as they move downstream. For long distances with poor pixel resolution or very shallow angles (down to a few degrees to the horizontal), the correlation of a spatial pattern is more likely to be lost, as compared to the line of a visible object or structure traveling downstream along an inspection line. In this sense STIV is more suited for long distances and shallow inclination angles from the camera to the water surface. The STIV method has a small computational load and is easy to perform real-time observations. Even mobile or portable STIV solutions are also available.
5 Fixed installations and temporary measurements
5.1 General
One of the great advantages of non-contact current meters is flexible installation. Unlike contact methods, they can be installed in a variety of ways, depending on the operators' intention as well as the conditions of the measurement section. The description of this chapter includes both, fixed and temporary measurement. Although several patterns of installation are possible, the options should be carefully considered in terms of the performance of each device. For all kind of installations, the following should be considered:
...