This clause of Part 1 is completely replaced by the following: This part of IEC 60669 applies to electronic control devices, a general term to cover electronic switches, home and building electronic systems (HBES) / building automation and control systems (BACS) switches and electronic extension units. It applies to electronic switches and to HBES/BACS switches, for alternating current (AC) only with a rated switching voltage not exceeding 250 V and a rated current not exceeding 16 A, intended for household and similar fixed electrical installations, either indoors or outdoors. It also applies to electronic extension units with a rated supply voltage not exceeding 250 V AC and 120 V DC, such as sensors and push buttons. This document also applies to electronic remote control switches (RCS) and electronic time delay switches (TDS). Particular requirements are given in Annex FF. Switches including only passive components such as resistors, capacitors, inductors, positive temperature coefficient (PTC) and negative temperature coefficient (NTC) components, varistors, printed wiring boards and connectors are not considered as electronic control devices. This document also applies to electronic switches and HBES/BACS switches for the operation of lighting equipment circuits and the control of the brightness of lighting equipment (dimmers) as well as the control of the speed of motors (for example, those used in ventilating fans) and for other purposes (for example, heating controls). The operation and/or control as mentioned above can be transmitted by an electronic signal via several media, for example, powerline (mains), twisted pair, optical fibre, radio frequency, infrared, etc. and are performed: - intentionally by a person via an actuating member, a key, a card, etc., via a sensing surface or a sensing unit, by means of touch, proximity, turn, optical, acoustic, thermal; - by physical means, for example, light, temperature, humidity, time, wind velocity, presence of people; - by any other influence. This document also applies to electronic control devices which include integrated radio receivers and transmitters. This document covers only those requirements for mounting boxes which are necessary for the tests on the electronic control devices. Requirements for general purpose mounting boxes are given in the relevant part, if any, of IEC 60670. This document is not intended to cover devices falling within the scope of IEC 60730 (all parts). Electronic control devices complying with this document are suitable for use at ambient temperature not normally exceeding 25 °C but occasionally reaching 35 °C with a lower limit of the ambient air temperature of −5 °C. NOTE 1 For lower temperatures, see Annex E. Functional safety aspects are not covered by this document. Functional safety requirements are covered by the standards of the controlled devices. In locations where special conditions prevail, such as in ships, vehicles and the like and in hazardous locations, for example where explosions are liable to occur, special construction and/or additional requirements may be required. This document is not intended to cover devices which are designed to be incorporated in appliances or are intended to be delivered together with a specific appliance and which are within the scope of IEC 60730 (all parts) or IEC 61058-1. Examples of designs of electronic switches and HBES/BACS switches and functions are shown in Annex AA. Additional requirements for electronic control devices using DLT-technology in accordance with IEC 62756-1 are given in Annex CC. Electrical interface specification for phase-cut dimmer used in phase-cut dimmed lighting systems are given for information only in Annex EE. NOTE 2 Electronic switches and HBES/BACS switches without a mechanical switch in the main circuit do not provide a "full off-state". Therefore, the circuit on the load side are to be considered to be live.

  • Draft
    120 pages
    English language
    sale 10% off
    e-Library read for
    1 day

To give requirements and tests for electronic control devices, a general term to cover electronic switches, HBES/BACS switches and electronic extension units. It applies to electronic switches and to HBES/BACS switches, for alternating current (AC) only with a rated switching voltage not exceeding 250 V and a rated current not exceeding 16 A, intended for household and similar fixed electrical installations, either indoors or outdoors. It also applies to electronic extension units with a rated supply voltage not exceeding 250 V AC and 120 V DC. This Part of IEC 60669 also applies to electronic control devices which include integrated radio receivers and transmitters.

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies statistical considerations for the evaluation of unwanted radio frequency emissions of mass-produced products. NOTE 1 It is based on CISPR TR 16-4-3. The reasons for such statistical considerations are: a) that the abatement of interference aims that the majority of the products to be approved shall not cause interference; b) that the CISPR limits should be suitable for the purpose of type approval of mass-produced products as well as approval of single-produced products; c) that to ensure compliance of mass-produced products with the CISPR limits, statistical techniques have to be applied; d) that it is important for international trade that the limits shall be interpreted in the same way in every country. Therefore, this document specifies requirements and provides guidance based on statistical techniques. EMC compliance of mass-produced products with the requirements of this document are based on the application of statistical techniques that reassure the consumer, with an 80 % degree of confidence, that 80 % of the products of a type being investigated comply with the limits for unintended radio frequency emission. This document does not define limits or measuring methods. It can be used only after measurements of unwanted radio frequency emissions have been performed according to the applicable standard for the unwanted radio frequency emissions. NOTE 2 Clause 4 gives some general requirements on the interpretation of CISPR radio disturbance limits and specifies different methods, which can be used alternatively. Clause 5 gives some specific requirements for certain product groups. NOTE 3 This document does not give a calculation method about the manufacturer’s risk, whether a type of products will be accepted during a second statistical evaluation. More information on the acceptance probability for a repeated measurement is given in CISPR TR 16 4 3, Edition 2.1, Annex D.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN-IEC 60947-5-2 applies to inductive and capacitive proximity switches that sense the presence of metallic and/or non-metallic objects, ultrasonic proximity switches that sense the presence of sound reflecting objects, photoelectric proximity switches that sense the presence of objects and non-mechanical magnetic proximity switches that sense the presence of objects with a magnetic field. Products covered by the scope of this document are not subjected to defined behaviours under fault conditions. Proximity switches with defined behaviour are covered by IEC 60947-5-3 and have to fulfil additional requirements. These proximity switches are self-contained, have semiconductor switching element(s) and are intended to be connected to circuits, the rated voltage of which does not exceed 250 V 50 Hz/60 Hz AC RMS or 300 V DC. Examples of typical applications for in-scope products: - factory automation and machinery industry; - logistic and packaging industry; - conveyor belts, lifts; - process industry; - power plants. Special applications (e.g. corrosive atmosphere) can cause additional requirements. This document is not intended to cover proximity switches with analogue outputs. The object of this document is to state for proximity switches: - definitions; - classification; - characteristics; - product information; - normal service, mounting and transport conditions; - constructional and performance requirements; - tests to verify rated characteristics. Products covered by the scope of this document are expected to be selected, installed, and maintained by skilled personnel only.

  • Amendment
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This clause of Part 1 is replaced by the following.
This International Standard deals with the safety of electric commercial amusement machines
and personal service machines, their rated voltage being not more than 250 V for singlephase appliances and 480 V for other appliances.
NOTE 101 Examples of appliances that are within the scope of this standard are
– amusement machines:
• tables;
• bowling machines;
• dartboards;
• driving simulators;
• gaming machines;
• kiddie rides;
• laser shooting appliances;
• pinball machines;
• video games;
• personal service machines;
• card re-value machines;
• currency dispensers;
• luggage lockers;
• weighing machines;
• shoe shining appliances.
As far as is practicable, this standard deals with the common hazards presented by
appliances that are encountered by users and maintenance persons.
NOTE 102 Attention is drawn to the fact that
– for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements may be
necessary;
– in many countries, additional requirements are specified by the national authorities responsible for health, for
the protection of labour and similar authorities.
NOTE 103 This standard does not apply to
– appliances intended exclusively for household use;
– appliances intended exclusively for industrial purposes;
– appliances intended to be used in locations where special conditions prevail, such as the presence of a
corrosive or explosive atmosphere (dust, vapour or gas);
– appliances for washing cars;
– dispensing appliances and vending machines (IEC 60335-2-75);
– appliances within the scope of IEC 60065, such as jukeboxes and household video games
– appliances within the scope of IEC 60950-1, such as copying machines, ticket machines and automatic teller
machines;
– appliances intended to be used when a trained attendant is present, such as virtual reality systems;
– equipment intended exclusively for fairgrounds, such as carousels;
– self-balancing personal transport devices.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN-IEC 60947-5-2 applies to inductive and capacitive proximity switches that sense the presence of metallic and/or non-metallic objects, ultrasonic proximity switches that sense the presence of sound reflecting objects, photoelectric proximity switches that sense the presence of objects and non-mechanical magnetic proximity switches that sense the presence of objects with a magnetic field. Products covered by the scope of this document are not subjected to defined behaviours under fault conditions. Proximity switches with defined behaviour are covered by IEC 60947-5-3 and have to fulfil additional requirements. These proximity switches are self-contained, have semiconductor switching element(s) and are intended to be connected to circuits, the rated voltage of which does not exceed 250 V 50 Hz/60 Hz AC RMS or 300 V DC. Examples of typical applications for in-scope products: - factory automation and machinery industry; - logistic and packaging industry; - conveyor belts, lifts; - process industry; - power plants. Special applications (e.g. corrosive atmosphere) can cause additional requirements. This document is not intended to cover proximity switches with analogue outputs. The object of this document is to state for proximity switches: - definitions; - classification; - characteristics; - product information; - normal service, mounting and transport conditions; - constructional and performance requirements; - tests to verify rated characteristics. Products covered by the scope of this document are expected to be selected, installed, and maintained by skilled personnel only.

  • Amendment
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60335-2-82:2017(E) deals with the safety of electric commercial amusement machines and personal service machines, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. Examples of appliances that are within the scope of this standard are: amusement machines; tables; bowling machines; dartboards; driving simulators; gaming machines; kiddie rides; laser shooting appliances; pinball machines; video games; personal service machines; card re-value machines; currency dispensers; luggage lockers; weighing machines; shoe shining appliances. As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by users and maintenance persons. For appliances intended to be used in vehicles or on board ships or aircraft, additional requirements may be necessary; This standard does not apply to appliances intended exclusively for household use; appliances intended exclusively for industrial purposes; appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas); appliances for washing cars; dispensing appliances and vending machines (IEC 60335-2-75); appliances within the scope of IEC 60065, such as jukeboxes and household video games; appliances within the scope of IEC 60950-1, such as copying machines, ticket machines and automatic teller machines; appliances intended to be used when a trained attendant is present, such as virtual reality systems; equipment intended exclusively for fairgrounds, such as carousels; self-balancing personal transport devices. This third edition cancels and replaces the second edition published in 2002 including its Amendment 1 (2008) and its Amendment 2 (2015). This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - It is clarified that 22.44 is not applicable to amusement machines; - Modified some Notes to make them normative text (5.6, 11.2, 11.8, 15.2.101, 15.2.102, 15.2.104, 15.3, 19.4, 19.101, 24.101, 24.102) and - Reference to 22.106 is made in Annex R. This publication has been drafted in accordance with the ISO/IEC Directives, Part 2. This part 2-82 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments. It was established on the basis of IEC 60335-1:2010, its Amendment 1:2013 and its Amendment 2:2016. The attention of National Committees is drawn to the fact that equipment manufacturers and testing organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this publication be adopted for implementation nationally not earlier than 12 months or later than 36 months from the date of publication. Key words: Amusement Machines, Personal Service Machines, Safety

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60974-10:2014 specifies a) applicable standards and test methods for radio-frequency (RF) emissions; b) applicable standards and test methods for harmonic current emission, voltage fluctuations and flicker; c) immunity requirements and test methods for continuous and transient, conducted and radiated disturbances including electrostatic discharges. This standard is applicable to equipment for arc welding and allied processes, including power sources and ancillary equipment, for example wire feeders, liquid cooling systems and arc striking and stabilizing devices. This third edition cancels and replaces the second edition published in 2007 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - inclusion of optional use of a decoupling network and a load outside the test chamber; - inclusion of an alternative test setup for portable equipment; - inclusion of test conditions for complex controls, liquid cooling systems and arc striking and stabilizing devices; - update of the applicable limits related to the updated reference to CISPR 11; - exclusion of the use of narrow band relaxations for RF emission limits; - update of the applicable limits for harmonics and flicker and inclusion of flow-charts related to the updated reference to IEC 61000-3-11 and IEC 61000-3-12; - update of the requirements for voltage dips related to the updated reference to IEC 61000-4-11 and IEC 61000-4-34; - update of the informative annex for installation and use; - inclusion of symbols to indicate the RF equipment class and restrictions for use.

  • Standard
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62135-2:2020 is available as IEC 62135-2:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62135-2:2020 is applicable to equipment for resistance welding and allied processes which are connected to mains supplies with rated voltages up to 1 000 V AC RMS. This document does not define safety requirements. This third edition cancels and replaces the second edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - update of the applicable limits related to the updated references; - implementation of radiated magnetic field requirements.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Technical Report illustrates good practice and provides guidance with regard to the term "reasonably foreseeable use" as it relate to product compliance assessment standards concerning the exposure of humans to electric, magnetic and electromagnetic fields (EMF) as required in the Radio Equipment Directive (RED) and Low Voltage Directive (LVD). Other safety aspects and requirements from other directives are not covered by this Technical Report.
This report uses the term "reasonably foreseeable use". In this context of this TR the terms "reasonably foreseeable conditions" and "conditions of use which can be reasonably foreseen" are interchangeable. The report provides guidance that is not specific to individual equipment. The report covers both occupational and general public use of equipment and also provides a rationale for the distinction between occupational use and use by the general public.

  • Technical report
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60051 applies to direct acting indicating wattmeters and varmeters having an
analogue display.
NOTE For multi-function instruments, see IEC 60051-7.
It also applies to:
• non-interchangeable accessories (as defined in 3.1.23 of IEC 60051-1:2016) used with
wattmeters and varmeters;
• a combination of the instruments and the accessories provided that the adjustments have
been made for the combination;
• direct acting indicating electrical measuring instruments whose scale marks do not
correspond directly to their electrical input quantity, provided that the relationship between
them is known;
• instruments and accessories having electronic devices in their measuring and/or auxiliary
circuits.
This document does not apply to:
– special purpose instruments which are covered by their own IEC standards;
– special purpose devices which are covered by their own IEC standards when they are
used as accessories.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60051 applies to direct acting indicating analogue frequency meters of the
following types:
• pointer-type frequency meters (as defined in 3.2.11 of IEC 60051-1:2016);
• vibrating-reed frequency meters (as defined in 3.2.12 of IEC 60051-1:2016).
This document also applies to non-interchangeable accessories (as defined in 3.1.23 of
IEC 60051-1:2016) used with frequency meters.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This Technical Report illustrates good practice and provides guidance with regard to the term "reasonably foreseeable use" as it relate to product compliance assessment standards concerning the exposure of humans to electric, magnetic and electromagnetic fields (EMF) as required in the Radio Equipment Directive (RED) and Low Voltage Directive (LVD). Other safety aspects and requirements from other directives are not covered by this Technical Report. This report uses the term "reasonably foreseeable use". In this context of this TR the terms "reasonably foreseeable conditions" and "conditions of use which can be reasonably foreseen" are interchangeable. The report provides guidance that is not specific to individual equipment. The report covers both occupational and general public use of equipment and also provides a rationale for the distinction between occupational use and use by the general public.

  • Technical report
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60051 applies to direct acting indicating ammeters and voltmeters having an
analogue display.
NOTE For multi-function instruments, see IEC 60051-7.
It also applies to:
• direct acting indicating ammeters and voltmeters whose scale marks do not correspond
directly to their electrical input quantity, provided that the relationship between them is
known;
• direct acting indicating ammeters and voltmeters and accessories having electronic
devices in their measuring and/or auxiliary circuits.
This document does not apply to:
– special purpose instruments which are covered by their own IEC standards;
– special purpose devices which are covered by their own IEC standards when they are
used as accessories.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The contents of the Interpretation sheet of August 2021 have been included in this copy. Apply to the English version only.

  • Amendment
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-6-3:2020 is a generic EMC emission standard applicable only if no relevant dedicated product or product family EMC emission standard has been published. This part of IEC 61000 for emission requirements applies to electrical and electronic equipment intended for use at residential (see 3.1.14) locations. This part of IEC 61000 also applies to electrical and electronic equipment intended for use at other locations that do not fall within the scope of IEC 61000-6-8 or IEC 61000-6-4. The intention is that all equipment used in the residential, commercial and light-industrial environments are covered by IEC 61000-6-3 or IEC 61000-6-8. If there is any doubt the requirements in IEC 61000-6-3 apply. The conducted and radiated emission requirements in the frequency range up to 400 GHz are considered essential and have been selected to provide an adequate level of protection of radio reception in the defined electromagnetic environment. Not all disturbance phenomena have been included for testing purposes but only those considered relevant for the equipment intended to operate within the locations included within this document. The emission requirements in this document are not intended to be applicable to the intentional transmissions and their harmonics from a radio transmitter as defined by the ITU. This third edition cancels and replaces the second edition published in 2006 and its Amendment 1:2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) alternative method for measuring conducted emissions on DC ports;
b) limits and requirements applicable only to equipment intended to be used in residential locations;
c) more stringent limits for DC power ports.
NOTE 1 Safety considerations are not covered by this document.
NOTE 2 In special cases, situations will arise where the levels specified in this document will not offer adequate protection; for example where a sensitive receiver is used in close proximity to an equipment. In these instances, special mitigation measures can be employed. NOTE 3 Disturbances generated in fault conditions of equipment are not covered by this document.
NOTE 4 As the requirements in this document are more stringent or equivalent to those requirements in IEC 61000-6-4 and IEC 61000-6-8, equipment fulfilling the requirements of this document comply with the requirements of IEC 61000-6-4 and IEC 61000-6-8.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EC 60730-2-8:2018 applies to electrically operated water valves for use in, on or in association with equipment for household and similar use, including heating, air-conditioning and similar applications. The equipment can use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof. This document is applicable to electrically operated water valves for building automation within the scope of ISO 16484. This document also applies to automatic electrically operated water valves for equipment that can be used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications. This document does not apply to electrically operated water valves intended exclusively for industrial process applications unless explicitly mentioned in the relevant equipment standard. This document applies to electrically operated water valves powered by primary or secondary batteries, requirements for which are contained within the standard, including Annex V. This document does not cover the prevention of contamination of drinking water as a result of contact with materials. This document applies to the inherent safety, to the operating values, operating times and operating sequences where such are associated with equipment safety, and to the testing of automatic electrical control devices used in, on or in association with, household and similar equipment. This document contains requirements for electrical features of water valves and requirements for mechanical features of valves that affect their intended operation. This document is also applicable to electrically operated water valves for appliances within the scope of the IEC 60335 series of standards. This document does not apply to:  
- electrically operated water valves of nominal connection size above DN 50;
- electrically operated water valves for admissible nominal pressure rating above 1,6 MPa;
- food dispensers;
- detergent dispensers;
- steam valves;
- electrically operated water valves designed exclusively for industrial applications. This document applies to electrically operated water valves, responsive to or controlling such characteristics as temperature, pressure, passage of time, humidity, light, electrostatic effects, flow, or liquid level, current, voltage, acceleration, or combinations thereof. This document also applies to actuators and to valve bodies which are designed to be fitted to each other. This document applies to individual valves, valves utilized as part of a system and valves mechanically integral with multi-functional controls having non-electrical outputs. This document applies to AC or DC powered electrically operated water valves with a rated voltage not exceeding 690 V AC or 600 V DC. This document does not take into account the response value of an automatic action of a valve, if such a response value is dependent upon the method of mounting the valve in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer shall apply.

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60051-3:2018 applies to direct acting indicating wattmeters and varmeters having an analogue display. IEC 60051-3:2018 also applies to: • non-interchangeable accessories (as defined in 3.1.23 of IEC 60051-1:2016) used with wattmeters and varmeters; • a combination of the instruments and the accessories provided that the adjustments have been made for the combination; • direct acting indicating electrical measuring instruments whose scale marks do not correspond directly to their electrical input quantity, provided that the relationship between them is known; • instruments and accessories having electronic devices in their measuring and/or auxiliary circuits. IEC 60051-3:2018 does not apply to: • special purpose instruments which are covered by their own IEC standards; • special purpose devices which are covered by their own IEC standards when they are used as accessories. IEC 60051-3:2018 cancels and replaces the fourth edition published in 1984 and Amendment 1:1994. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) updating of content in line with new editions of IEC 60051-1 and IEC 60051-9; b) addition of Annex A to specify the nonconformity classification of test items. IEC 60051-3:2018 is to be used in conjunction with IEC 60051-1:2016.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60051-2:2018 applies to direct acting indicating ammeters and voltmeters having an analogue display. It also applies to: • direct acting indicating ammeters and voltmeters whose scale marks do not correspond directly to their electrical input quantity, provided that the relationship between them is known; • direct acting indicating ammeters and voltmeters and accessories having electronic devices in their measuring and/or auxiliary circuits. This document does not apply to: • special purpose instruments which are covered by their own IEC standards; • special purpose devices which are covered by their own IEC standards when they are used as accessories. IEC 60051-2:2018 cancels and replaces the fourth edition published in 1984. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) updating of content in line with new editions of IEC 60051-1 and IEC 60051-9; b) addition of Annex A to specify the nonconformity classification of test item. This International Standard is to be used in conjunction with IEC 60051-1:2016.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60051-4:2018 applies to direct acting indicating analogue frequency meters of the following types: • pointer-type frequency meters (as defined in 3.2.11 of IEC 60051-1:2016); • vibrating-reed frequency meters (as defined in 3.2.12 of IEC 60051-1:2016). IEC 60051-4:2018 also applies to non-interchangeable accessories (as defined in 3.1.23 of IEC 60051-1:2016) used with frequency meters. IEC 60051-4:2018 cancels and replaces the fourth edition published in 1984. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) updating of content in line with new editions of IEC 60051-1 and IEC 60051-9; b) addition of Annex A to specify the nonconformity classification of test items. IEC 60051-4:2018 is to be used in conjunction with IEC 60051-1:2016.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The contents of the Interpretation sheet of August 2021 have been included in this copy. Apply to the English version only.

  • Amendment
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61000-6-3:2020 is a generic EMC emission standard applicable only if no relevant dedicated product or product family EMC emission standard has been published. This part of IEC 61000 for emission requirements applies to electrical and electronic equipment intended for use at residential (see 3.1.14) locations. This part of IEC 61000 also applies to electrical and electronic equipment intended for use at other locations that do not fall within the scope of IEC 61000-6-8 or IEC 61000-6-4. The intention is that all equipment used in the residential, commercial and light-industrial environments are covered by IEC 61000-6-3 or IEC 61000-6-8. If there is any doubt the requirements in IEC 61000-6-3 apply. The conducted and radiated emission requirements in the frequency range up to 400 GHz are considered essential and have been selected to provide an adequate level of protection of radio reception in the defined electromagnetic environment. Not all disturbance phenomena have been included for testing purposes but only those considered relevant for the equipment intended to operate within the locations included within this document. The emission requirements in this document are not intended to be applicable to the intentional transmissions and their harmonics from a radio transmitter as defined by the ITU. This third edition cancels and replaces the second edition published in 2006 and its Amendment 1:2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) alternative method for measuring conducted emissions on DC ports; b) limits and requirements applicable only to equipment intended to be used in residential locations; c) more stringent limits for DC power ports. NOTE 1 Safety considerations are not covered by this document. NOTE 2 In special cases, situations will arise where the levels specified in this document will not offer adequate protection; for example where a sensitive receiver is used in close proximity to an equipment. In these instances, special mitigation measures can be employed. NOTE 3 Disturbances generated in fault conditions of equipment are not covered by this document. NOTE 4 As the requirements in this document are more stringent or equivalent to those requirements in IEC 61000-6-4 and IEC 61000-6-8, equipment fulfilling the requirements of this document comply with the requirements of IEC 61000-6-4 and IEC 61000-6-8.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document applies, when required by the relevant product standard, to low-voltage
switchgear and controlgear hereinafter referred to as "equipment" or “device” and intended to
be connected to circuits, the rated voltage of which does not exceed 1 000 V AC or
1 500 V DC.
This document states the general rules and common safety requirements for low-voltage
switchgear and controlgear, including:
− definitions;
− characteristics;
− information supplied with the equipment;
− normal service, mounting and transport conditions, decommissioning and dismantling;
− constructional and performance requirements;
− verification of characteristics and performance;
− energy efficiency aspects (see Annex V);
− environmental aspects.
This document does not apply to:
− low-voltage switchgear and controlgear assemblies which are dealt with in IEC 61439
series, as applicable;
− terminals for connection of aluminium conductors;
NOTE Terminals for aluminium conductors are under consideration for the next revision.
− use within explosive atmospheres (see IEC 60079 series);
− software and firmware requirements for functional safety application (see IEC 61508-3);
− cyber security aspects (see IEC 62443 series).

  • Standard
    292 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    309 pages
    French language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    298 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

IEC 60947-1:2020 applies, when required by the relevant product standard, to low-voltage switchgear and controlgear hereinafter referred to as "equipment" or “device” and intended to be connected to circuits, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC. This document states the general rules and common safety requirements for low-voltage switchgear and controlgear, including: - definitions; - characteristics; - information supplied with the equipment; - normal service, mounting and transport conditions, decommissioning and dismantling; - constructional and performance requirements; - verification of characteristics and performance; - energy efficiency aspects (see Annex V); - environmental aspects. This sixth edition cancels and replaces the fifth edition published in 2007, Amendment 1:2010 and Amendment 2:2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: – DC values testing improvement; – update of EMC tests; – Annex B deletion; – update of requirements for environmental tests (Table Q.1); – improvement of Annex R (new examples); – deletion of digital input Type 2, and introduction of Type 3 in Annex S; – example for materials declaration (Annex W); – new Annex X (co-ordination between short-circuit protective devices associated in the same circuit) created.

  • Standard
    292 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    309 pages
    French language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    298 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

2020-10-13: BT D167/C020 to remove EMC and RED link and proceed with the project without link to legislation
2019-12-05: TC decision to carry on implementation as NON hEN - link EMC and RED removed
2019-12-03: NEXT ACTION: TC
2019:12-03: TC decided to set up AHG to look into aligning this AMD with EU regulatory requirements

  • Amendment
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-08-05 NEXT ACTION: CCMC action by 2020-08-31
2020-08-03 CCMC to prepare request for BT
2020-08-03 since no 2nd assessment allowed, EC confirmed that TC met requirements for pos. ass.  
2019-02-20 PC: "lack of compliance" for LVD, TC to adress comments
2019-01-30 PC: Sent for LVD assessment
2018-03-22 - missing Annex ZZ - on hold
2017-10-05 - Cannot allocate for publication due to missing assessment from Consultant.

  • Amendment
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric clothes dryers for drying textiles on racks located in a warm airflow, clothes dryers intended for drying footwear or gloves and to electric towel rails, for household and similar purposes, their rated voltage being not more than 250 V.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-10-13: BT D167/C020 to remove EMC and RED link and proceed with the project without link to legislation
2019-12-05: TC decision to carry on implementation as NON hEN - link EMC and RED removed
2019-12-03: NEXT ACTION: TC
2019:12-03: TC decided to set up AHG to look into aligning this AMD with EU regulatory requirements

  • Amendment
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60335-2-43:2017(E) deals with the safety of electric clothes dryers for drying textiles on racks located in a warm airflow, clothes dryers intended for drying footwear or gloves and to electric towel rails, for household and similar purposes, their rated voltage being not more than 250 V. The clothes racks can be fixed or free-standing in a cabinet. The air circulation can be natural or forced. Appliances not intended for normal household use but that nevertheless may be a source of danger to the public, such as appliances intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard. As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home. However, in general, it does not take into account persons (including children) whose physical, sensory or mental capabilities or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction or children playing with the appliance. Attention is drawn to the fact that for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements may be necessary. This standard does not apply to spin extractors (IEC 60335-2-4): - tumble dryers (IEC 60335-2-11); - appliances intended exclusively for industrial purposes or appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas). This fourth edition cancels and replaces the third edition published in 2002 including its Amendment 1 (2005) and its Amendment 2 (2008). This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: requirements for clothes dryers intended for drying footwear or gloves have been introduced (1, 3.1.9, 6.2, 11.8, 19.1, 19.13, 19.101, 19.102, 22.40, 23.3). This part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments. It was established on the basis of the fifth edition (2010) of that standard. The attention of National Committees is drawn to the fact that equipment manufacturers and testing organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this publication be adopted for implementation nationally not earlier than 12 months or later than 36 months from the date of its publication.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN-IEC 62368-1 is a product safety standard that classifies energy sources, prescribes safeguards against those energy sources, and provides guidance on the application of, and requirements for, those safeguards. The prescribed safeguards are intended to reduce the likelihood of pain, injury and, in the case of fire, property damage. The objective of the INTRODUCTION is to help designers to understand the underlying principles of safety in order to design safe equipment. These principles are informative and not an alternative to the detailed requirements of this document.

  • Amendment
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Amendment to indicate the complete list of standards to be superseded by EN 55035:2017

  • Amendment
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This clause of Part 1 is applicable except as follows: 1.1.1 Equipment included in scope Replacement: Replace the second paragraph by the following: This part of IEC 61010 specifies particular safety requirements for the following types a) to c) of electrical equipment and their accessories, wherever they are intended to be used, whenever the heating of materials is one of the functions of the equipment. Addition: Add the following text after item c): It is possible that all or part of the equipment falls within the scope of one or more other Part 2 standards of IEC 61010 as well as within the scope of this standard. In that case, the requirements of those other Part 2 standards will also apply. In particular, if equipment is intended to be used for in vitro diagnostic (IVD) purposes, the requirements of IEC 61010-2-101 will also apply. However, when the equipment incorporates a refrigerating system and a heating function where the combination of the two introduces additional or more severe HAZARDS than if treated separately, then it is possible that IEC 61010-2-012 is applicable instead of this Part 2-010. See further information in the flow chart (Figure 102) for the selection process and the guidance in the Introduction. 1.1.2 Equipment excluded from scope Addition: Add the following items after item j): aa) equipment for the heating and ventilation of laboratories; bb) sterilizing equipment; cc) heating and/or cooling equipment which the OPERATOR is intended to enter, and which is large enough for the OPERATOR to remain inside with the door or doors closed.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2021-10-08: EC GPSD request NOT to offer this AC because only corrects the French version. Link GPSD removed
TAN - // IEC Corrigendum

  • Corrigendum
    3 pages
    French language
    sale 10% off
    e-Library read for
    1 day

NEW!IEC 60730-2-8:2018 is available as IEC 60730-2-8:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60730-2-8:2018 applies to electrically operated water valves for use in, on or in association with equipment for household and similar use, including heating, air-conditioning and similar applications. The equipment can use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof. This document is applicable to electrically operated water valves for building automation within the scope of ISO 16484. This document also applies to automatic electrically operated water valves for equipment that can be used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications. This document does not apply to electrically operated water valves intended exclusively for industrial process applications unless explicitly mentioned in the relevant equipment standard. This document applies to electrically operated water valves powered by primary or secondary batteries, requirements for which are contained within the standard, including Annex V. This document does not cover the prevention of contamination of drinking water as a result of contact with materials. This document applies to the inherent safety, to the operating values, operating times and operating sequences where such are associated with equipment safety, and to the testing of automatic electrical control devices used in, on or in association with, household and similar equipment. This document contains requirements for electrical features of water valves and requirements for mechanical features of valves that affect their intended operation. This document is also applicable to electrically operated water valves for appliances within the scope of the IEC 60335 series of standards. This document does not apply to: - electrically operated water valves of nominal connection size above DN 50; - electrically operated water valves for admissible nominal pressure rating above 1,6 MPa; - food dispensers; - detergent dispensers; - steam valves; - electrically operated water valves designed exclusively for industrial applications. This document applies to electrically operated water valves, responsive to or controlling such characteristics as temperature, pressure, passage of time, humidity, light, electrostatic effects, flow, or liquid level, current, voltage, acceleration, or combinations thereof. This document also applies to actuators and to valve bodies which are designed to be fitted to each other. This document applies to individual valves, valves utilized as part of a system and valves mechanically integral with multi-functional controls having non-electrical outputs. This document applies to AC or DC powered electrically operated water valves with a rated voltage not exceeding 690 V AC or 600 V DC. This document does not take into account the response value of an automatic action of a valve, if such a response value is dependent upon the method of mounting the valve in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer shall apply. This document applies also to electrically operated water valves incorporating electronic devices, requirements for which are contained in

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEXT ACTION: PART OF A PACKAGE
2018-10-01: Positive assessment from NAC received on 2018-10-01. BT doc prepared and to be submitted to 4 weeks consultation
2018-09-14 CV: Positive assessment expected (info from NAC) but not yet uploaded on HAS Livelink folder -- BT doc for publication awaiting official assessment
2018-09-06 CV: New request for assessment sent on 2018-08-12 -- EN 60335-2-6:2015/FprA1 (PR=63514) and EN 60335-2-6:2015/FprAA (PR=62259) have been voted upon without Annex ZZ. The projects could not proceed. CLC/TC 61 worked on the Annex ZZ which, if positively assessed by the LVD consultant will be added to EN 60335-2-6:2015/FprAA (PR=62259).
If both positively assessed, EN 60335-2-6:2015/FprA1 (PR=63514) and EN 60335-2-6:2015/FprAA (PR=62259) will be published on the same date.
2018-06-25: Consultant's assessment is missing at CDV stage.

  • Amendment
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN-IEC 62368-1 is a product safety standard that classifies energy sources, prescribes safeguards against those energy sources, and provides guidance on the application of, and requirements for, those safeguards. The prescribed safeguards are intended to reduce the likelihood of pain, injury and, in the case of fire, property damage. The objective of the INTRODUCTION is to help designers to understand the underlying principles of safety in order to design safe equipment. These principles are informative and not an alternative to the detailed requirements of this document.

  • Standard
    381 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEXT ACTION: PART OF A PACKAGE
2018-10-01: Positive assessment from NAC received on 2018-10-01. BT doc prepared and to be submitted to 4 weeks consultation
2018-09-14 CV: Positive assessment expected (info from NAC) but not yet uploaded on HAS Livelink folder -- BT doc for publication awaiting official assessment
2018-09-06 CV: New request for assessment sent on 2018-08-12 -- EN 60335-2-6:2015/FprA1 (PR=63514) and EN 60335-2-6:2015/FprAA (PR=62259) have been voted upon without Annex ZZ. The projects could not proceed. CLC/TC 61 worked on the Annex ZZ which, if positively assessed by the LVD consultant will be added to EN 60335-2-6:2015/FprAA (PR=62259).
If both positively assessed, EN 60335-2-6:2015/FprA1 (PR=63514) and EN 60335-2-6:2015/FprAA (PR=62259) will be published on the same date.
2018-06-25: Consultant's assessment is missing at CDV stage.

  • Amendment
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEXT ACTION: PUBLICATION EXPECTED BY 2020-04

  • Amendment
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEXT ACTION: CCMC to finalize publication
2019-11-13 PeC: BT approved the publication
2019-03-21 - GEM - TC discussed with consultant (C. Maes) at meeting (MArch 2019) - comments accepted - Annex ZA to be dated. Project has normative refverence to PR=63474, which creates a dependency.
2019-02-28 PC: to be flagged for LVD citation when ready
2018-12-17 PC: "Lack of compliance" for LVD, undated references in the Annex ZA and some points in the standards should be clarified
2017-11-21 - Negative assessment is received during CDV stage. Consultant assessment request is missing for FDIS.

  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60947-5-2:2019 applies to inductive and capacitive proximity switches that sense the presence of metallic and/or non-metallic objects, ultrasonic proximity switches that sense the presence of sound reflecting objects, photoelectric proximity switches that sense the presence of objects and non-mechanical magnetic proximity switches that sense the presence of objects with a magnetic field. This fourth edition cancels and replaces the third edition published in 2007 and Amendment 1:2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:  update of the scope; adaptation and update of the construction requirements according to IEC Guide 116 (e.g. material requirements, artificial optical radiation, instruction requirements, hot surface, unattended operation, foreseeable misuse…); modification of the specifications concerning the sensing range and operating distance; new definitions for photoelectric proximity switch type D with background suppression; integration of the requirements and test procedures of photoelectric proximity switch type D with background suppression; update of EMC requirements in Table 9 and Table 10; integration of environmental information requirements and environmental condition by referencing Annexes O, W and Q of IEC 60947-1:2007, IEC 60947-1:2007/AMD1:2010 and IEC 60947-1:2007/AMD2:2014; modification of impulse withstand voltage test (5.3.1.3, 9.3.3.4.5); modification of the references in the (normative) standard body to the (informative) Annex A; major update of Annex A (definitions update, new dimensions and shapes); update of C.9.1.1; update of Annex D in order to consider new connector types and normative references; update of Annex F (additional symbols for photoelectric proximity switches).

  • Standard
    137 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2019-10-29: D164/C050: Amendment to add Annex ZZ to EN 55032:2015 & enable citation in OJEU

  • Amendment
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN-IEC 60335-2-71 deals with the safety of all kinds of electrical heating appliances used for livestock rearing and breeding, such as: heat-radiating appliances, electrical sittinghens, incubators, chicken breeding units and heating plates for animals, the rated voltage of the appliances being not more than 250 V for single-phase appliances and 480 V for other appliances.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEW!IEC 62368-1:2018 is available as IEC 62368-1:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62368-1:2018 is applicable to the safety of electrical and electronic equipment within the field of audio, video, information and communication technology, and business and office machines with a rated voltage not exceeding 600 V. This document does not include requirements for performance or functional characteristics of equipment. This is a product safety standard that classifies energy sources, prescribes safeguards against those energy sources, and provides guidance on the application of, and requirements for, those safeguards. The prescribed safeguards are intended to reduce the likelihood of pain, injury and, in the case of fire, property damage. This third edition cancels and replaces the second edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: – addition of requirements for outdoor equipment; – new requirements for optical radiation; – addition of requirements for insulating liquids; – addition of requirements for work cells; – addition of requirements for wireless power transmitters; – addition of requirements for fully insulated winding wire (FIW); – alternative method for determination of top, bottom and side openings for fire enclosures; – alternative requirements for sound pressure. This group safety publication is primarily intended to be used as a product safety standard for the products mentioned in the scope, but shall also be used by technical committees in the preparation of standards for products similar to those mentioned in the scope of this standard, in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51. Key words: Audio, Video, Communication, Safety

  • Standard
    381 pages
    English language
    sale 10% off
    e-Library read for
    1 day