This part of IEC 60704 applies to electric fan heaters, designed for placing on the floor, table
or counter, etc., or for mounting.
This document does not apply to
– electric storage room heaters;
– room humidifiers;
– room dehumidifiers;
– air cleaners;
– heaters designed exclusively for industrial purposes.
For determining and verifying noise emission values declared in product specifications, refer
to IEC 60704-3:2019.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60704-2-2:2023 is available as IEC 60704-2-2:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60704-2-2:2023 applies to electric fan heaters, designed for placing on the floor, table or counter, etc., or for mounting. This document does not apply to: - electric storage room heaters; - room humidifiers; - room dehumidifiers; - air cleaners; - heaters designed exclusively for industrial purposes. For determining and verifying noise emission values declared in product specifications, refer to IEC 60704-3:2019. This third edition cancels and replaces the second edition published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - alignment with the latest edition of IEC 60704-1:2021, - addition of several ISO standards, - revision of built-in-conditions, - addition of requirements on climatic conditions and on background noise. This part 2-2 is intended to be used in conjunction with the fourth edition of IEC 60704-1:2021, Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 1: General requirements. This part 2-2 supplements or modifies the corresponding clauses in IEC 60704-1:2021.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric foot warmers and heating mats for household and similar purposes, their rated voltage being not more than 250 V.

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric foot warmers and heating mats for household and similar purposes, their rated voltage being not more than 250 V.

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60704-2-2:2023 is available as IEC 60704-2-2:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60704-2-2:2023 applies to electric fan heaters, designed for placing on the floor, table or counter, etc., or for mounting. This document does not apply to:
- electric storage room heaters;
- room humidifiers;
- room dehumidifiers;
- air cleaners;
- heaters designed exclusively for industrial purposes.
For determining and verifying noise emission values declared in product specifications, refer to IEC 60704-3:2019. This third edition cancels and replaces the second edition published in 2009. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- alignment with the latest edition of IEC 60704-1:2021,
- addition of several ISO standards,
- revision of built-in-conditions,
- addition of requirements on climatic conditions and on background noise.
This part 2-2 is intended to be used in conjunction with the fourth edition of IEC 60704-1:2021, Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 1: General requirements.
This part 2-2 supplements or modifies the corresponding clauses in IEC 60704-1:2021.

  • Standard
    40 pages
    English language
    sale 15% off
  • Standard
    58 pages
    English language
    sale 15% off
  • Standard
    98 pages
    English language
    sale 15% off
  • Standard
    98 pages
    English language
    sale 15% off
  • Standard
    25 pages
    English and French language
    sale 15% off

IEC 60335-2-53:2011 deals with the safety of electric sauna heating appliances and infrared emitting units having a rated power input not exceeding 20 kW, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. The appliances covered by this standard are intended for use in the home and in public saunas located in blocks of flats, hotels and similar locations. This standard also deals with the safety of electric sauna heating appliances provided with a humidifier unit, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. The room air is humidified by evaporating or atomising water. This fourth edition cancels and replaces the third edition published in 2002 and its Amendment 1 (2007). It constitutes a technical revision. The principal changes in this edition as compared with the third edition of IEC 60335-2-53 are as follows:  - the scope is changed to cover infrared cabins;  - additional requirements for recessed sauna heaters are added;  - requirements of electronic interlocks are added (22.108).  The attention of National Committees is drawn to the fact that equipment organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this publication be adopted for implementation nationally not earlier than 12 months or later than 36 months from the date of publication.   This publication is to be read in conjunction with IEC 60335-1:2010.

  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard deals with the safety of electric sauna heating appliances and infrared emitting units having a rated power input not exceeding 20 kW, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances

  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60335-2-53:2011 deals with the safety of electric sauna heating appliances and infrared emitting units having a rated power input not exceeding 20 kW, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. The appliances covered by this standard are intended for use in the home and in public saunas located in blocks of flats, hotels and similar locations. This standard also deals with the safety of electric sauna heating appliances provided with a humidifier unit, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. The room air is humidified by evaporating or atomising water. This fourth edition cancels and replaces the third edition published in 2002 and its Amendment 1 (2007). It constitutes a technical revision. The principal changes in this edition as compared with the third edition of IEC 60335-2-53 are as follows: - the scope is changed to cover infrared cabins; - additional requirements for recessed sauna heaters are added; - requirements of electronic interlocks are added (22.108). The attention of National Committees is drawn to the fact that equipment organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this publication be adopted for implementation nationally not earlier than 12 months or later than 36 months from the date of publication. This publication is to be read in conjunction with  IEC 60335-1:2010.

  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard deals with the safety of electric sauna heating appliances and infrared emitting units having a rated power input not exceeding 20 kW, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances

  • Amendment
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The contents of the corrigendum of March 2017 have been included in this copy.

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEXT ACTION: TB ACTION by 2021-01-31 (TC to send text after drop of voting results - D167/C064)
HAS ASSESSMENT BY 2019-09-27
2019-01-23 CV: blocked until ratification of pr64193 is completed

  • Amendment
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60335-2-81:2015 deals with the safety of electric foot warmers and heating mats for household and similar purposes, their rated voltage being not more than 250 V. Appliances not intended for normal household use but which nevertheless may be a source of danger to the public, such as appliances intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard. As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home. However, in general, it does not take into account persons (including children) whose physical, sensory or mental capabilities; or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction. It also does not take into account children playing with the appliance. It was established on the basis of the fifth edition (2010) of that standard. This third edition cancels and replaces the second edition published in 2002, its Amendment 1 (2007) and its Amendment 2 (2011). It constitutes a technical revision. The principal changes in this edition as compared with the second edition of IEC 60335-2-81 are as follows (minor changes are not listed):
- requirements for washable appliances (5.3, 7.1, 7.6, 7.12);
- requirements for controls in flexible cords (15.1.1, 24.2) and requirements for appliance inlets (22.105, 24.1.5, 29.1.3). The attention of National Committees is drawn to the fact that equipment manufacturers and testing organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this standard be adopted for implementation nationally not earlier than 12 months or later than 36 months from the date of its publication.
Key words: Foot warmer, heating element, heating mat

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric foot warmers and heating mats for household and similar purposes, their rated voltage being not more than 250 V.

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

NEXT ACTION: TB ACTION by 2021-01-31 (TC to send text after drop of voting results - D167/C064)
HAS ASSESSMENT BY 2019-09-27
2019-01-23 CV: blocked until ratification of pr64193 is completed

  • Amendment
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric foot warmers and heating mats for household and similar purposes, their rated voltage being not more than 250 V.

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60335-2-71:2018 deals with the safety of all kinds of electrical heating appliances used for livestock rearing and breeding, such as: heat-radiating appliances, electrical sitting-hens, incubators, chicken breeding units and heating plates for animals, the rated voltage of the appliances being not more than 250 V for single-phase appliances and 480 V for other appliances. This standard applies to heating appliances used for livestock rearing and breeding that include an electrical motor. This standard does not apply to: - appliances designed exclusively for industrial purposes; - appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas); - heating units embedded in the floor; - flexible sheet heating elements for room heating (IEC 60335-2-96); - room heaters (IEC 60335-2-30). This third edition cancels and replaces the second edition published in 2002, its Amendment 1 (2007) and its Amendment 2 (2012). This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - two paragraphs are deleted (Introduction); - normative references updated (Clause 2); - colour required for symbols (7.6); - some notes converted to normative text (19.2, 21.101, 22.104).

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2018-09-14 CV: Positive assessment expected (info from NAC) but not yet uploaded on HAS Livelink folder -- BT doc for publication awaiting official assessment
2018-08-12 CV: New assessment requested

  • Amendment
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard applies to electronic control equipment for heating systems with direct electrical emission, which have an integrated outside compensated function and or optimum start/stop function.
This control equipment controls the distribution and/or the generation of heat in relation to the outside temperature and time and other reference variables.
This European Standard also covers controllers that contain an integrated optimum start or an optimum start-stop control function. The controller modulates heating or control modes of electronic individual zone or emitter control equipment.
Safety requirements on heating systems remain unaffected by this standard. The dynamic behaviour of the local thermostats, sensors, or actuators is not covered in this standard.
A multi-distribution and/or multi-generation system needs a coordinated solution to prevent undesired interaction and is not part of this standard.
Table 1 shows the relative position of this standard within the set of EPB standards in the context of the modular structure as set out in EN ISO 52000-1.
NOTE 1   In CEN ISO/TR 52000-2 the same table can be found, with, for each module, the numbers of the relevant EPB standards and accompanying technical reports that are published or in preparation.
NOTE 2   The modules represent EPB standards, although one EPB standard may cover more than one module and one module may be covered by more than one EPB standard, for instance a simplified and a detailed method respectively.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to electronic control equipment for heating systems with direct electrical emission, which have an integrated outside compensated function and or optimum start/stop function.
This control equipment controls the distribution and/or the generation of heat in relation to the outside temperature and time and other reference variables.
This document is also applicable to controllers that contain an integrated optimum start or an optimum start-stop control function. The controller modulates heating or control modes of electronic individual zone or emitter control equipment.
Safety requirements on heating systems remain unaffected by this document. The dynamic behaviour of the local thermostats, sensors, or actuators is not covered in this document.
A multi-distribution and/or multi-generation system needs a coordinated solution to prevent undesired interaction and is not part of this document.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard deals shavers, hair clippers and similar appliances for domestic use

  • Amendment
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60335-2-81:2015 deals with the safety of electric foot warmers and heating mats for household and similar purposes, their rated voltage being not more than 250 V. Appliances not intended for normal household use but which nevertheless may be a source of danger to the public, such as appliances intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard. As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home. However, in general, it does not take into account persons (including children) whose physical, sensory or mental capabilities; or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction. It also does not take into account children playing with the appliance. It was established on the basis of the fifth edition (2010) of that standard. This third edition cancels and replaces the second edition published in 2002, its Amendment 1 (2007) and its Amendment 2 (2011). It constitutes a technical revision. The principal changes in this edition as compared with the second edition of IEC 60335-2-81 are as follows (minor changes are not listed): - requirements for washable appliances (5.3, 7.1, 7.6, 7.12); - requirements for controls in flexible cords (15.1.1, 24.2) and requirements for appliance inlets (22.105, 24.1.5, 29.1.3). The attention of National Committees is drawn to the fact that equipment manufacturers and testing organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this standard be adopted for implementation nationally not earlier than 12 months or later than 36 months from the date of its publication. Key words: Foot warmer, heating element, heating mat

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric room heaters for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. This standard also deals with the safety of electric heaters intended for the heating of driver and passenger compartments of motor vehicles when they are stationary, their rated voltage being not more than 250 V.

  • Amendment
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2021-06-03: This prAD includes common mods to EN 60335-2-30:2009/A2 (PR=74100)

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric room heaters for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. This standard also deals with the safety of electric heaters intended for the heating of driver and passenger compartments of motor vehicles when they are stationary, their rated voltage being not more than 250 V.

  • Amendment
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2021-06-03: This prAD includes common mods to EN 60335-2-30:2009/A2 (PR=74100)

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2019-01-16 CV: LVD assessment  uploaded on HAS tool on 2018-12-29 (deadline: 2019-02-04). If positively assessed, project can proceed to BT (1 month consultation) for the approval of the new Annex ZZ
2017-05-02: D156/C084 - Ratified standards not being made available.
2017-09-07: publication pending due to missing Annex ZZ
2021: CLC legacy converted by DCLab NISOSTS

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60704-2-18:2022 applies to single-unit electric water heaters for household and similar use intended for placing on the floor against a wall, for building-in or placing under a counter, a kitchen worktop or under a sink, for wall-mounting or on a counter.
This document does not apply to:
– combustion water heaters;
– water kettles;
– heat pump water heaters;
– conventional electric storage water heaters as defined in IEC 60335-2-21:2012, Clause 1;
– instantaneous electric water heaters without any noise-producing components such as motors and pumps.
This document is intended to be used in conjunction with IEC 60704‑1:2021.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60704-2-18:2022 applies to single-unit electric water heaters for household and similar use intended for placing on the floor against a wall, for building-in or placing under a counter, a kitchen worktop or under a sink, for wall-mounting or on a counter. This document does not apply to: – combustion water heaters; – water kettles; – heat pump water heaters; – conventional electric storage water heaters as defined in IEC 60335-2-21:2012, Clause 1; – instantaneous electric water heaters without any noise-producing components such as motors and pumps. This document is intended to be used in conjunction with IEC 60704‑1:2021.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60704-2-18:2022 applies to single-unit electric water heaters for household and similar use intended for placing on the floor against a wall, for building-in or placing under a counter, a kitchen worktop or under a sink, for wall-mounting or on a counter.
This document does not apply to:
– combustion water heaters;
– water kettles;
– heat pump water heaters;
– conventional electric storage water heaters as defined in IEC 60335-2-21:2012, Clause 1;
– instantaneous electric water heaters without any noise-producing components such as motors and pumps.
This document is intended to be used in conjunction with IEC 60704‑1:2021.

  • Standard
    33 pages
    English and French language
    sale 15% off

This document applies to electrical instantaneous water heaters designed to operate as multifunctional appliances with an electric rated power > 2 kW.
This document specifies tests for the assessment of the performance.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document applies to open outlet, single point-of-use, electric instantaneous water heaters
intended for household or similar use, for showering purposes without downstream mixing.
This document only specifies tests for the assessment of energy efficiency.
This document does not apply to electrical instantaneous water heaters covered by other parts
of this series of standards

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document applies to electric instantaneous water heaters for domestic hot water heating
for household and similar applications, which show both of the following characteristics:
– fulfilling at least one load pattern from Annex A;
– heating up to temperatures below the boiling temperature.
This document specifies terms, definitions and measurement methods for the assessment of
energy efficiency.
This document does not take into account requirements regarding the safety of the appliances

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of flexible sheet heating elements intended to be incorporated into floors and walls below 1,2 m and above 2,3 m and in ceilings, their rated voltage being not more than 250 V for single-phase installations and 480 V for other installations.

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of flexible sheet heating elements intended to be incorporated into floors and walls below 1,2 m and above 2,3 m and in ceilings, their rated voltage being not more than 250 V for single-phase installations and 480 V for other installations.

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of flexible sheet heating elements intended to be incorporated into floors and walls below 1,2 m and above 2,3 m and in ceilings, their rated voltage being not more than 250 V for single-phase installations and 480 V for other installations.

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of flexible sheet heating elements intended to be incorporated into floors and walls below 1,2 m and above 2,3 m and in ceilings, their rated voltage being not more than 250 V for single-phase installations and 480 V for other installations.

  • Amendment
    5 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with the safety of electric thermal-storage room heaters intended to heat the room in which they are located, their rated voltage being not more than 250 V for single phase and 480 V for other appliances.

  • Amendment
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60335-2-106:2021 is available as IEC 60335-2-106:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60335-2-106:2021 deals with the safety of
- portable heated carpets;
- heated carpets and similar appliances;
- heating units to heat the room in which they are located and that are intended to be installed directly under materials used as a removable floor covering such as carpet, cushion vinyl, or loose laid laminate,
their rated voltage being not more than 250 V for single-phase installations and 480 V for other installations, including direct current (DC) supplied appliances.
Attention is drawn to the fact that
- in many countries different wiring rules apply;
- for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary;
- in many countries additional requirements are specified by the national authorities for fire protection, the national authorities for building regulations, the national health authorities, the national authorities responsible for the protection of labour and similar authorities.
This standard does not apply to
- appliances intended exclusively for industrial purposes;
- appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas);
- blankets, pads and similar flexible heating appliances (IEC 60335-2-17);
- heated mats and foot warmers with an area not exceeding 0,5 m2 (IEC 60335-2-81);
- flexible sheet heating systems permanently incorporated in the floor of the building structure (IEC 60335-2-96);
- flexible heating elements incorporated in other appliances;
- battery-operated appliances.
This second edition cancels and replaces the first edition published in 2007. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) the text has been aligned with IEC 60335-1:2020;
b) some notes have been converted to normative text (Clause 1, 5.2, 5.3, 5.6, 7.12.1, 7.101, 10.1, 18.101.1, 18.101.2, 18.102.5, 19.1, 19.103, 21.1, 21.104, 21.105, 30.102);
c) requirements for portable heated carpets have been added (Clause 1, 5.2, 5.5, 6.1, 6.2, 7.1, 7.6, 7.12, 7.14, 7.101, 11.8, 15.1, 15.101, 16.1, 16.2, 16.3, 19.101, 19.102. 19.103, 21.105, 21.106, 24.1.5, 24.2, 29.3);
d) requirements for washable portable heated carpets have been added (5.3, 7.1, 7.6, 7.12, 7.14);
e) the test of 30.102 has been updated.
This Part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments unless that edition precludes it; in that case, the latest edition that does not preclude it is used. It was established on the basis of the sixth edition (2020) of that standard.

  • Standard
    134 pages
    English language
    sale 15% off
  • Standard
    89 pages
    English and French language
    sale 15% off

This European Standard deals with the safety of electric thermal-storage room heaters intended to heat the room in which they are located, their rated voltage being not more than 250 V for single phase and 480 V for other appliances.

  • Amendment
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62999:2016 applies to electrical underfloor heating of dwellings and all other buildings whose use corresponds to dwellings or is at least similar, having a maximum load bearing in use of 4 kN/m2. This Standard defines the main characteristics of electrical underfloor heating and establishes the method of testing of these characteristics as information for the user. This Standard does not deal with installation and safety requirements.

  • Standard
    122 pages
    English and French language
    sale 15% off
  • Standard
    290 pages
    English and French language
    sale 15% off

IEC 60335-2-53:2011 deals with the safety of electric sauna heating appliances and infrared emitting units having a rated power input not exceeding 20 kW, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. The appliances covered by this standard are intended for use in the home and in public saunas located in blocks of flats, hotels and similar locations. This standard also deals with the safety of electric sauna heating appliances provided with a humidifier unit, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. The room air is humidified by evaporating or atomising water. This fourth edition cancels and replaces the third edition published in 2002 and its Amendment 1 (2007). It constitutes a technical revision. The principal changes in this edition as compared with the third edition of IEC 60335-2-53 are as follows:
- the scope is changed to cover infrared cabins;
- additional requirements for recessed sauna heaters are added;
- requirements of electronic interlocks are added (22.108).
The attention of National Committees is drawn to the fact that equipment organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this publication be adopted for implementation nationally not earlier than 12 months or later than 36 months from the date of publication.
This publication is to be read in conjunction with  IEC 60335-1:2010.

  • Standard
    61 pages
    English and French language
    sale 15% off
  • Standard
    133 pages
    English and French language
    sale 15% off
  • Standard
    124 pages
    English and French language
    sale 15% off

IEC 60335-2-30:2009 Deals with the safety of electric room heaters for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. Examples of appliances that are included are:
- convection heaters;
- fan heaters;
- heaters for greenhouses;
- liquid-filled radiators;
- panel heaters;
- radiant heaters;
- tubular heaters;
- ceiling mounted heat lamp appliances.
The principal changes in this edition as compared with the fourth edition of IEC 60335-2-30 are as follows:
- some additional instructions are introduced for heaters without a built-in thermostat,
- or those installed in the floor or in a bathroom (7.12 and 7.12.1);
- a spillage test is introduced for appliances having a grille and - that are built into the floor (15.2).
The attention of National Committees is drawn to the fact that equipment manufacturers and testing organizations may need a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance with the new requirements and to equip themselves for conducting new or revised tests. It is the recommendation of the committee that the content of this publication be adopted for implementation nationally not earlier than 12 months or later than 36 months from the date of publication.
This publication is to be read in conjunction with IEC 60335-1:2010. The contents of the corrigendum of November 2014 have been included in this copy.

  • Standard
    30 pages
    English language
    sale 15% off
  • Standard
    61 pages
    English and French language
    sale 15% off
  • Standard
    153 pages
    English and French language
    sale 15% off
  • Standard
    161 pages
    English and French language
    sale 15% off

This clause of IEC 60675:1994 is applicable, with the following modification:
Replace the first paragraph with the following content:
This document applies to electric direct-acting room heaters .
This document defines performance characteristics related to the radiant effect and specifies
methods for measuring the radiant factor for the information of users.
This document is used to measure the radiant factor of direct-acting room heaters.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60675-3 applies to electric direct-acting room heaters.This document defines performance characteristics related to the radiant effect and specifiesmethods for measuring the radiation efficiency for the information of users.This document is used to measure the radiation efficiency of direct-acting room heaters.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60675-2:2020 applies to electric direct-acting room heaters. This document defines performance characteristics related to the radiant effect and specifies methods for measuring the radiant factor for the information of users. This document is used to measure the radiant factor of direct-acting room heaters. This International Standard is to be used in conjunction with IEC 60675:1994, IEC 60675:1994/AMD1:1998 and IEC 60675:1994/AMD2:2018.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day