SIST EN 60531:2002/A12:2026
(Amendment)Household electric thermal storage room heaters - Methods for measuring performance
Household electric thermal storage room heaters - Methods for measuring performance
Applies to electric storage heaters intended to heat the room in which they are located. It defines the main performance characteristics and describes methods for measuring these characteristics. It does not apply to heating appliances incorporated in the building structure, to central heating systems or to floor heating appliances.
Elektrische Wärmespeicher - Raumheizgeräte für den Hausgebrauch - Verfahren zur Messung der Gebrauchseigenschaften
Appareils électrodomestiques de chauffage à accumulation des locaux - Méthodes de mesure de l'aptitude à la fonction
Gospodinjski termoakumulacijski grelniki - Metode za merjenje učinkovitost delovanja - Dopolnilo A12
General Information
- Status
- Published
- Public Enquiry End Date
- 11-Sep-2025
- Publication Date
- 16-Apr-2026
- Technical Committee
- FGA - Consumer information related to household electrical appliances
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 09-Apr-2026
- Due Date
- 14-Jun-2026
- Completion Date
- 17-Apr-2026
Relations
- Effective Date
- 01-Jun-2026
Overview
SIST EN 60531:2002/A12:2026 is the key European standard specifying methods for measuring the performance of household electric thermal storage room heaters. Developed by CLC (CENELEC), this standard is applicable to electric storage heaters designed for direct room heating and defines the essential performance characteristics of these appliances. It details uniform testing procedures to provide reliable, comparable information for manufacturers, consumers, and regulators. The amendment A12:2026 updates terminology, references, and measurement methods, supporting industry alignment with current practices and energy efficiency needs.
Scope limitation: The standard does not cover heating appliances integrated into building structures, central heating systems, or floor heating appliances.
Key Topics
Performance Characteristics
- Nominal heat output
- Maximum and minimum heat output
- Heat retention and maximum storage capacity
- Room temperature stability and control accuracy
Testing and Measurement Methods
- Room heating capability under real-world conditions
- Power consumption in various low power modes (off, standby, idle, networked standby)
- Use of standardized climatic test rooms and control scenarios for repeatable results
Control and Functionality
- Description of manual and electronic heat charge and room temperature controls
- Integration of advanced features, including self-learning functions
- Measurement and reporting of control accuracy, control variation, and deviation from setpoint temperature
Terminology and Definitions
- Clear distinctions between local space heaters, storage heaters, and direct-acting appliances
- Standardized definitions for control types, heat outputs, and low power operation modes
Applications
SIST EN 60531:2002/A12:2026 is essential for:
Manufacturers
- Ensuring compliance through standardized energy performance and functionality testing
- Providing transparent product information, supporting competitive market positioning
- Developing new features (e.g., smart controls, self-learning) with confidence in testability
Testing Laboratories
- Implementing consistent, accurate laboratory procedures for electric storage heater evaluation
- Calibration and certification aligned with European market requirements
Regulators and Market Surveillance
- Reference for verifying manufacturer claims and supporting eco-design initiatives
- Facilitation of market harmonization within the European Economic Area
Consumers
- Access to reliable data on heater efficiency, control options, and energy consumption in low power modes
- Informed decision-making based on standardized performance comparisons
Related Standards
Key references included or acknowledged within SIST EN 60531:2002/A12:2026:
- EN 50564:2011 – Measurement of low power consumption of household and office equipment
- IEC 62301 – Measurement of standby power in electrical appliances
- EN 15500-1 – Control for heating, ventilating, and air conditioning applications: zone controller requirements and evaluations
- EN IEC 63474:2023 – Networked standby power consumption measurement for edge equipment
Safety and Noise:
For safety specifications and acoustical noise measurement, refer to:
- EN 60335-2-61 – Safety requirements for electric room heaters
- EN 60704-2-5 – Measurement of noise emitted by household electric thermal storage heaters
By adhering to SIST EN 60531:2002/A12:2026, stakeholders ensure that electric thermal storage room heaters are tested and reported on a consistent basis, fostering product quality, energy efficiency, and consumer trust in the European marketplace.
Frequently Asked Questions
SIST EN 60531:2002/A12:2026 is a amendment published by the Slovenian Institute for Standardization (SIST). Its full title is "Household electric thermal storage room heaters - Methods for measuring performance". This standard covers: Applies to electric storage heaters intended to heat the room in which they are located. It defines the main performance characteristics and describes methods for measuring these characteristics. It does not apply to heating appliances incorporated in the building structure, to central heating systems or to floor heating appliances.
Applies to electric storage heaters intended to heat the room in which they are located. It defines the main performance characteristics and describes methods for measuring these characteristics. It does not apply to heating appliances incorporated in the building structure, to central heating systems or to floor heating appliances.
SIST EN 60531:2002/A12:2026 is classified under the following ICS (International Classification for Standards) categories: 97.100 - Domestic, commercial and industrial heating appliances; 97.100.10 - Electric heaters. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 60531:2002/A12:2026 has the following relationships with other standards: It is inter standard links to SIST EN 60531:2002. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 60531:2002/A12:2026 is associated with the following European legislation: EU Directives/Regulations: 2015/1188; Standardization Mandates: M/550. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 60531:2002/A12:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-junij-2026
Gospodinjski termoakumulacijski grelniki - Metode za merjenje učinkovitost
delovanja - Dopolnilo A12
Household electric thermal storage room heaters - Methods for measuring performance
Elektrische Wärmespeicher - Raumheizgeräte für den Hausgebrauch - Verfahren zur
Messung der Gebrauchseigenschaften
Appareils électrodomestiques de chauffage à accumulation des locaux - Méthodes de
mesure de l'aptitude à la fonction
Ta slovenski standard je istoveten z: EN 60531:2000/A12:2026
ICS:
97.100.10 Električni grelniki Electric heaters
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD EN 60531:2000/A12
NORME EUROPÉENNE
EUROPÄISCHE NORM April 2026
ICS 97.100
English Version
Household electric thermal storage room heaters - Methods for
measuring performance
Appareils électrodomestiques de chauffage à accumulation Elektrische Wärmespeicher - Raumheizgeräte für den
des locaux - Méthodes de mesure de l'aptitude à la fonction Hausgebrauch - Verfahren zur Messung der
Gebrauchseigenschaften
This amendment A12 modifies the European Standard EN 60531:2000; it was approved by CENELEC on 2026-03-09. CENELEC members
are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the status of a
national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Türkiye and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2026 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 60531:2000/A12:2026 E
Contents Page
European foreword . 3
1 Modification to Clause 1, “Scope” . 4
2 Modification to Clause 2, “Normative references” . 4
3 Modification to Clause 3, “Terms and definitions” . 4
4 Modification to Clause 5, “List of measurements” . 8
5 Modifications to Clause 6, “General conditions for measurements” . 8
6 Modification to Clause 9, “Room heating capability” . 9
7 Modification to Clause 10, “Heat retention” . 9
8 Modification of Clause 13, “Stability of room temperature” .10
9 Modification to Clause 15, “Control types and functionality” .12
10 Modification to Annex B, “Climatic test room” .13
11 Modification to Annex D .13
12 Modifications to the Bibliography .14
13 Deletion of Annex ZZ, “Relationship between this European Standard and the Ecodesign
requirements of Commission Regulation EU No 2015/1188 aimed to be covered” .14
European foreword
This document (EN 60531:2000/A12:2026) has been prepared by CLC/TC 59X “Performance of household and
similar electrical appliances”.
The following dates are fixed:
• latest date by which this document has to be (dop) 2027-04-30
implemented at national level by publication of
an identical national standard or by
endorsement
• latest date by which the national standards (dow) 2029-04-30
conflicting with this document have to be
withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Any feedback and questions on this document should be directed to the users’ national committee. A complete
listing of these bodies can be found on the CENELEC website.
1 Modification to Clause 1, “Scope”
Replace the content of Clause 1 with the following:
“This document applies to electric storage heaters having a daily operating cycle and intended to heat the room
in which they are located.
NOTE 1 This document does not apply to heating appliances incorporated in the building structure, to central heating
systems or to floor heating installations.
NOTE 2 If an appliance is intended to be operated as a storage heater or as a direct-acting room heater, it is also tested
in accordance with EN 60675.
NOTE 3 If an appliance has a heat retention of less than 20 %, it is not considered to be a storage heater.
This document defines the main performance characteristics of storage heaters and specifies methods for
measuring these characteristics, for the information of users.
NOTE 4 Information which can be of interest to the consumer is listed in Annex D.
This document does not specify values for performance characteristics.
NOTE 5 This document does not deal with:
— safety requirements (EN 60335-2-61);
— acoustical noise of electric thermal storage room heaters (EN 60704-2-5).”
2 Modification to Clause 2, “Normative references”
Add the following reference:
EN 50564:2011, Electrical and electronic household and office equipment - Measurement of low power
consumption
3 Modification to Clause 3, “Terms and definitions”
Replace the content of Clause 3 with the following:
“For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— IEC Electropedia: available at https://www.electropedia.org/
— ISO Online browsing platform: available at https://www.iso.org/obp
3.1
local space heater
device equipped with one or more heat generators to convert electricity from the mains or gaseous or liquid
fuels directly into heat output to provide thermal comfort for human beings in the enclosed space in which it is
situated by direct heat transfer, possibly combined with heat output to other spaces or with heat transfer to a
fluid
3.2
storage local space heater
electric local space heater designed to store heat in an accumulating isolated core and to discharge it for several
hours after the accumulation phase
3.3
minimum discharge condition
condition under which the appliance is operated, the means for controlling the heat output, such as flaps and
fans, being set at the lowest position
3.4
maximum discharge condition
condition under which the appliance is operated, the means for controlling the heat output, such as flaps and
fans, being set at the highest position, any boost position being ignored
Note 1 to entry: A boost position is a setting of a control for occasional use which results in a higher temporary fan speed.
3.5
maximum storage capacity
Q
max
amount of thermal energy which can be accumulated inside the storage heater, and which is available for space
heating after the heating elements are switched off
3.6
average room temperature
arithmetic average of the maximum and minimum room temperatures for a setting of the room temperature
control
3.7
room temperature control
mechanical or electronic device, sensitive to the room temperature and adjustable by the user
3.8
amplitude
difference between the maximum and the minimum room temperatures for a setting of the room temperature
control
3.9
drift
difference between the average room temperatures obtained at different charge levels for a setting of the
room temperature control
3.10
nominal heat output
P
nom
heat output of a local space heater comprising both direct heat output and indirect heat output (where
applicable), when operating at the setting for the maximum heat output that can be maintained over an
extended period, as declared by the manufacturer, expressed in x,xxx kW
3.11
minimum heat output
P
min
heat output of a local space heater comprising both direct heat output and indirect heat output (where
applicable), when operating at the setting of the lowest heat output, as declared by the manufacturer, expressed
in x,xxx kW
3.12
maximum heat output
P
max
declared heat output of an electric local space heater when operating at the setting of the maximum heat
output that can be maintained continuously over an extended period, as declared by the manufacturer,
expressed in x,xxx kW
3.13
electric power consumption in low power modes
P P P P
o, sm, idle, nsm
electric power consumption of the product while in the respective low power mode - off mode, standby mode;
idle mode, or networked standby mode -, expressed in x,xx W
3.14
standby mode
condition where the product is connected to the mains power source and provides only one or more of the
following functions, which may persist for an indefinite time:
a) reactivation function, or reactivation function and indication of enabled reactivation function;
b) reactivation function through a connection to a network (‘networked standby’);
c) information or status display;
Note 1 to entry: In standby mode there is no disconnection from the supply. The status can be indicated by the symbol
ISO 7000/IEC 60417 [5009] or some indication as explained by the manufacturer.
3.15
networked standby
networked standby mode
condition in which the equipment is able to resume a function by way of a remotely initiated trigger from a
network connection;
3.16
reactivation function
function that via a remote switch, a remote control, an internal sensor or timer provides a switch from standby
mode to another mode, including active mode, providing additional functions
3.17
off mode
mode in which the product is connected to the mains power source and is not providing any function, or it is in
a condition providing only:
a) an indication of off mode condition;
b) functionalities intended to ensure electromagnetic compatibility
Note 1 to entry: In the off mode the circuit controlled by the switch is disconnected from the supply.
3.18
idle mode
condition in which the product is connected to the mains power source and is able to automatically provide heat
to the room according to the setpoint temperature
3.19
active mode
condition in which the product is connected to the mains power source and at least one of the main functions
providing the intended service of the equipment has been activated
Note 1 to entry: During charging – i.e. while accumulating thermal energy inside the storage heater – the storage heater is
in an active mode.
3.20
set-back function
function which allows the room temperature to be maintained at a predefined lower value than the pre-set
(comfort) temperature without changing the setting of the room temperature control
3.21
manual heat charge control with integrated thermostat
manually operated sensing device integrated into the product, which measures and regulates its core
temperature to vary the accumulated amount of heat
3.22
manual heat charge control with room and/or external temperature feedback
manually operated sensing device integrated into the product which measures its core temperature and varies
the accumulated amount of heat in relation with the room temperature and/or outdoor temperature
3.23
electronic heat charge control with room and/or external temperature feedback
automatically operated sensing device integrated into the product which measures its core temperature and
varies the accumulated amount of heat in relation with either the outdoor temperature or the heat demand of
the room, or both
3.24
fan assisted heat output
means the product is equipped with an integrated and controllable fan (or fans) to vary the output of the stored
energy according to the heat demand
3.25
mechanical room temperature control
non-electronic device that allows the product to automatically vary its heat output over a certain time period, in
relation to a certain required level of indoor heating comfort
3.26
electronic room temperature control
electronic device, either integrated or external, that allows the product to automatically vary its heat output over
a certain time period, in relation to a certain required level of indoor heating comfort
3.27
electronic room temperature control plus day timer
electronic device, either integrated or external, that allows the product to automatically vary its heat output over
a certain time period and in relation to a certain required level of indoor heating comfort according to settings
entered by the user, allowing the user to set timing and temperature level for a 24-hours timer interval
3.28
electronic room temperature control plus week timer
electronic device, either integrated or external, that allows the product to automatically vary its heat output over
a certain time period and in relation to a certain required level of indoor heating comfort according to settings
entered by the user, allowing the user to set timing and temperature levels for a full week
Note 1 to entry: During the 7-day period the settings shall allow a variation on a day-to-day basis.
3.29
room temperature control with open window detection
electronic device, either integrated or external, that automatically either switches to frost protection mode or
limits the energy consumption of the local space heater to the level of energy consumption of the idle mode
when a window or door has been opened
Note 1 to entry: Whenever a sensor is used to detect the opening of a window or door, it can be installed with the product,