29.140.40 - Luminaires
ICS 29.140.40 Details
Luminaires
Leuchten
Luminaires
Svetila
General Information
e-Library Subscription
Create subscription and get permanent access to documents within 29.140.40 - Luminaires
Currently subscription includes documents marked with .We are working on making all documents available within the subscription.
IEC 60598-2-1:2025 specifies requirements for fixed general purpose luminaires for use with electric light sources on supply voltages not exceeding 1 000 V. This third edition cancels and replaces the second edition published in 2020. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) The clause numbers and structure have been aligned with those of IEC 60598‑1.
- Standard7 pagesEnglish languagesale 15% off
- Standard7 pagesFrench languagesale 15% off
- Standard14 pagesEnglish and French languagesale 15% off
IEC 61995-1:2025 applies to devices for the connection of luminaires (DCL) intended for household and similar purposes, for the electrical connection of fixed luminaires of class I or class II to final circuits rated at not more than 16 A without mechanical support for the luminaires incorporated in the plug/outlet interface. The DCL retention mechanisms are not intended to support the weight of the luminaires.
This second edition cancels and replaces the first edition published in 2005 and Amendment 1:2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) additional requirements and tests for additional suspension means;
b) additional requirements and tests for additional functions;
c) additional requirements and tests for floating type DCLs;
d) introduction of insulation piercing terminals (IPT);
e) additional classification according to the connection capacities of the DCL outlet terminals;
f) modification of maximum withdrawal force for plugs with enabled locking means;
g) improvements of temperature rise tests.
- Standard86 pagesEnglish languagesale 15% off
- Standard89 pagesFrench languagesale 15% off
- Standard175 pagesEnglish and French languagesale 15% off
IEC 61995-2:2025, which is used in conjunction with IEC 61995‑1:2025, applies to devices for the connection of luminaires (DCL) 250 V AC, 6 A intended for household and similar purposes, for the electrical connection of fixed luminaires. It defines an interface design as specified in the given standard sheets.
This second edition cancels and replaces the first edition published in 2009 and Amendment 1:2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) technical requirements related to the force required to withdraw the plug have been moved to IEC 61995-1;
b) alignment with new edition of IEC 61995-1.
- Standard9 pagesEnglish languagesale 15% off
- Standard9 pagesFrench languagesale 15% off
- Standard18 pagesEnglish and French languagesale 15% off
IEC 60598-1:2024 specifies general safety requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. Requirements for semi-luminaires are included in this document.
This tenth edition cancels and replaces the ninth edition published in 2020. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) new structure to comply with the ISO/IEC Directives, Part 2;
b) addition of a new Annex V for comparison with the previous edition;
c) revision of 7.32 for SPDs and for SPCs;
d) the terms "live part" and "active part" were reviewed and aligned with the definitions of "live part" and "hazardous live part" given in IEC 60050-195;
e) revision of 7.14.2 for conductor mechanical stress;
f) revision of 14.5.2, Item 4 to include controlgear;
g) revision of 9.2.1 (Earthing) with the deletion of the word "permanently";
h) revision of Annex N: earth continuity test time;
i) revision of 7.11.4; 7.14.1; Table 22 (14.4.3): Introduction of requirements for suspension by magnets;
j) addition of a new Annex W for luminaires using batteries;
k) clarification of Clause 6 for marking requirements for nature of supply;
l) addition of a new Subclause 7.31.5: Additional requirements for luminaires using controllable controlgear providing SELV output(s);
m) revision of 6.4.16: Information to be provided for luminaire having protective earth current > 10 mA;
n) revision of 6.3.23; 6.4.18; 6.4.24; 7.30 and 10.2.1 for serviceable, non-user serviceable and non-serviceable components;
o) revision of Annex D: Draught-proof enclosure;
p) revision of 8.2.1 and 13.2.1: Inconsistencies in the inclusion of the limits of voltage ranges;
q) revision of 9.2.10 for looping-in;
r) Revision of Clause 2 and 7.8: update of the reference to IEC 61058-1-1, IEC 61058-1-2 and IEC 6105821. Update of temperature limits in Table 21 (14.4.3) for luminaires incorporating switches according to IEC 60669-1 or IEC 60669-2-1;
s) revision of 6.3.22 and 7.24 for photobiological safety;
t) addition of a new Subclause 6.3.27 for marking of mains socket outlet moved from information requirements.
- Standard254 pagesEnglish languagesale 10% offe-Library read for1 day
2022-01-12: This prAA includes common mods to prEN IEC (PR=71577)
- Amendment25 pagesEnglish languagesale 10% offe-Library read for1 day
2022-01-12: This prAA includes common mods to prEN IEC (PR=71577)
- Amendment25 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60598-1:2024 specifies general safety requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. Requirements for semi-luminaires are included in this document. This tenth edition cancels and replaces the ninth edition published in 2020. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) new structure to comply with the ISO/IEC Directives, Part 2; b) addition of a new Annex V for comparison with the previous edition; c) revision of 7.32 for SPDs and for SPCs; d) the terms "live part" and "active part" were reviewed and aligned with the definitions of "live part" and "hazardous live part" given in IEC 60050-195; e) revision of 7.14.2 for conductor mechanical stress; f) revision of 14.5.2, Item 4 to include controlgear; g) revision of 9.2.1 (Earthing) with the deletion of the word "permanently"; h) revision of Annex N: earth continuity test time; i) revision of 7.11.4; 7.14.1; Table 22 (14.4.3): Introduction of requirements for suspension by magnets; j) addition of a new Annex W for luminaires using batteries; k) clarification of Clause 6 for marking requirements for nature of supply; l) addition of a new Subclause 7.31.5: Additional requirements for luminaires using controllable controlgear providing SELV output(s); m) revision of 6.4.16: Information to be provided for luminaire having protective earth current > 10 mA; n) revision of 6.3.23; 6.4.18; 6.4.24; 7.30 and 10.2.1 for serviceable, non-user serviceable and non-serviceable components; o) revision of Annex D: Draught-proof enclosure; p) revision of 8.2.1 and 13.2.1: Inconsistencies in the inclusion of the limits of voltage ranges; q) revision of 9.2.10 for looping-in; r) Revision of Clause 2 and 7.8: update of the reference to IEC 61058-1-1, IEC 61058-1-2 and IEC 6105821. Update of temperature limits in Table 21 (14.4.3) for luminaires incorporating switches according to IEC 60669-1 or IEC 60669-2-1; s) revision of 6.3.22 and 7.24 for photobiological safety; t) addition of a new Subclause 6.3.27 for marking of mains socket outlet moved from information requirements.
- Standard254 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60598-1:2024 specifies general safety requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. Requirements for semi-luminaires are included in this document.
This tenth edition cancels and replaces the ninth edition published in 2020. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) new structure to comply with the ISO/IEC Directives, Part 2;
b) addition of a new Annex V for comparison with the previous edition;
c) revision of 7.32 for SPDs and for SPCs;
d) the terms "live part" and "active part" were reviewed and aligned with the definitions of "live part" and "hazardous live part" given in IEC 60050-195;
e) revision of 7.14.2 for conductor mechanical stress;
f) revision of 14.5.2, Item 4 to include controlgear;
g) revision of 9.2.1 (Earthing) with the deletion of the word "permanently";
h) revision of Annex N: earth continuity test time;
i) revision of 7.11.4; 7.14.1; Table 22 (14.4.3): Introduction of requirements for suspension by magnets;
j) addition of a new Annex W for luminaires using batteries;
k) clarification of Clause 6 for marking requirements for nature of supply;
l) addition of a new Subclause 7.31.5: Additional requirements for luminaires using controllable controlgear providing SELV output(s);
m) revision of 6.4.16: Information to be provided for luminaire having protective earth current > 10 mA;
n) revision of 6.3.23; 6.4.18; 6.4.24; 7.30 and 10.2.1 for serviceable, non-user serviceable and non-serviceable components;
o) revision of Annex D: Draught-proof enclosure;
p) revision of 8.2.1 and 13.2.1: Inconsistencies in the inclusion of the limits of voltage ranges;
q) revision of 9.2.10 for looping-in;
r) Revision of Clause 2 and 7.8: update of the reference to IEC 61058-1-1, IEC 61058-1-2 and IEC 6105821. Update of temperature limits in Table 21 (14.4.3) for luminaires incorporating switches according to IEC 60669-1 or IEC 60669-2-1;
s) revision of 6.3.22 and 7.24 for photobiological safety;
t) addition of a new Subclause 6.3.27 for marking of mains socket outlet moved from information requirements.
- Standard786 pagesEnglish languagesale 15% off
IEC 62305-2:2024 is applicable to the risk management of a structure due to lightning flashes to earth.
Its purpose is to provide a procedure for the evaluation of such a risk. Once an upper tolerable limit for the risk has been selected, this procedure provides a means for the selection of appropriate protection measures to be adopted to reduce the risk to or below the tolerable limit.
This third edition cancels and replaces the second edition, published in 2010. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) The concept of a single risk, to combine loss of human life and loss due to fire, has been introduced.
b) The concept of frequency of damage that can impair the availability of the internal systems within the structure has been introduced.
c) The lightning ground strike-point density NSG has been introduced replacing the lightning flash density NG in the evaluation of expected average annual number of dangerous events.
d) Reduction of a few risk components can be achieved by the use of preventive temporary measures activated by means of a thunderstorm warning system (TWS) compliant with IEC 62793. The risk of direct strike to people in open areas has been introduced, considering the reduction of that risk using a TWS.
The content of the corrigendum 1 (2024-10) has been included in this copy.
- Standard256 pagesEnglish and French languagesale 15% off
2021-03-02: This prAA represents CMs to EN IEC 60598-2-20 (PR=72048)
- Amendment4 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60598-2-20:2022 is available as IEC 60598-2-20:2022 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60598-2-20:2022 specifies requirements for lighting chains fitted with series, parallel or a combination of series/parallel connected light sources for use either indoors or outdoors on supply voltages not exceeding 250 V. This fifth edition cancels and replaces the fourth edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- specific provisions for temporarily installed protected lighting (TPL) chains have been added;
- new terms and definitions have been added.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
2021-03-02: This prAA represents CMs to EN IEC 60598-2-20 (PR=72048)
- Amendment4 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60598 specifies requirements for recessed luminaires incorporating electric light sources for operation from supply voltages up to 1 000 V. It also specifies requirements for recessed air-handling luminaires for use with a ventilation duct or ventilated space (plenum).
NOTE The expressions “ventilation” and “ventilated” in this section refer to forced ventilation.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
- Corrigendum1 pageEnglish, French and German languagesale 10% offe-Library read for1 day
- Standard2 pagesEnglish and French languagesale 15% off
This document specifies safety requirements for radio-integrated lighting equipment.
NOTE 1 Examples for lighting equipment are light sources, lamps, luminaires and controlgear for light sources.
NOTE 2 With the radio equipment integrated into the lighting equipment, the lighting equipment itself becomes radio
equipment which is subject to the provisions of the RED.
- Standard9 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62722-2-1:2023 specifies the performance requirements for LED luminaires, together with the test methods and conditions. It applies to LED luminaires for general lighting purposes. Semi-luminaires are not covered under the scope of this document. This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- alignment with IEC 62717:2014, IEC 62717:2014/AMD1:2015 and IEC 62717:2014/AMD2:2019;
- clarification of temperature requirements for the maintenance test, in 10.2 and Annex A;
- introduction of a new Annex C on methods for calculation and measurements of parameters for extension of electric and photometric data.
- Standard32 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62722-2-1:2023 specifies the performance requirements for LED luminaires, together with the test methods and conditions. It applies to LED luminaires for general lighting purposes. Semi-luminaires are not covered under the scope of this document. This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
alignment with IEC 62717:2014, IEC 62717:2014/AMD1:2015 and IEC 62717:2014/AMD2:2019;
clarification of temperature requirements for the maintenance test, in 10.2 and Annex A;
introduction of a new Annex C on methods for calculation and measurements of parameters for extension of electric and photometric data.
- Standard32 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62722-2-1:2023 specifies the performance requirements for LED luminaires, together with the test methods and conditions. It applies to LED luminaires for general lighting purposes. Semi-luminaires are not covered under the scope of this document. This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
alignment with IEC 62717:2014, IEC 62717:2014/AMD1:2015 and IEC 62717:2014/AMD2:2019;
clarification of temperature requirements for the maintenance test, in 10.2 and Annex A;
introduction of a new Annex C on methods for calculation and measurements of parameters for extension of electric and photometric data.
- Standard57 pagesEnglish languagesale 15% off
- Standard57 pagesEnglish and French languagesale 15% off
NEXT ACTION: PUBLICATION EXPECTED BY 2020-04
- Amendment13 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60598-2-20:2022 is available as IEC 60598-2-20:2022 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60598-2-20:2022 specifies requirements for lighting chains fitted with series, parallel or a combination of series/parallel connected light sources for use either indoors or outdoors on supply voltages not exceeding 250 V. This fifth edition cancels and replaces the fourth edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - specific provisions for temporarily installed protected lighting (TPL) chains have been added; - new terms and definitions have been added.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60598 specifies requirements for fixed luminaires intended for use in the water, or in contact with the water, in, for example, the basins of swimming pools, fountains, paddling pools, and garden pools, for use with electric light sources.
NOTE Electrical installation rules for swimming pools are given in IEC 60364-7-702.
This document does not cover luminaires not in contact with the water (e.g. mounted behind a glass panel which is separate from the luminaire) or hand-held or portable luminaires.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
No scope available
- Amendment10 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60598 specifies requirements for fixed luminaires intended for use in the water, or in contact with the water, in, for example, the basins of swimming pools, fountains, paddling pools, and garden pools, for use with electric light sources. NOTE Electrical installation rules for swimming pools are given in IEC 60364-7-702. This document does not cover luminaires not in contact with the water (e.g. mounted behind a glass panel which is separate from the luminaire) or hand-held or portable luminaires.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
No scope available
- Amendment10 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 62722 covers specific performance and environmental requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. Unless otherwise detailed, performance data covered under the scope of this document are for the luminaires in a condition representative of new manufacture, with any specified initial aging procedures completed.
This document covers requirements for luminaires to support energy efficient use and responsible environmental management to the end of life. The object of this document is to provide a set of requirements which are considered to be generally applicable to most types of luminaires. Where additional performance requirements for specific types of light source are relevant, these are specified in the IEC 62722-2 series. The IEC 62722-2 series can also cover a wider scope of performance aspects appropriate to the particular light source technology.
Semi-luminaires are not covered under the scope of this document.
For some types of luminaires (e.g. decorative or household) the provision of performance data under the scope of this document is not appropriate.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60598 specifies requirements for emergency luminaires for use with electrical lamps on emergency power supplies not exceeding 1 000 V.
This document does not cover the effects of non-emergency voltage reductions on luminaires incorporating high pressure discharge lamps.
This document gives general requirements for emergency lighting equipment.
In this document, the term "lamp" which also includes "light source(s)" where appropriate, is used.
- Standard46 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60598-2-18:2022 specifies requirements for fixed luminaires intended for use in water, or in contact with water, in, for example, the basins of swimming pools, fountains, paddling pools, and garden pools, and for use with electric light sources.
This third edition cancels and replaces the second edition published in 1993 and Amendment 1:2011. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
references to Part 1 have been updated;
some subclauses have been renumbered;
the standard has been redrafted such that it is applicable to both filament lamps and LED light sources;
marking requirements have been updated and 18.5.3 of the previoius edition has been deleted;
18.10.3 of the previous edition has been deleted, as it is no longer relevant, following the update of requirements for cross-sectional areas of external and internal cables in Section 5 of Part 1;
18.10.4 and 18.10.5 of the previous edition renumbered as 18.11.4 and 18.11.5 in this edition have been adapted to allow the use of an alternative waterproof multi-core cable that conforms to the waterproof test of Annex D and Annex E of EN 50525‑2‑21:2011 or to an equivalent regional standard;
in 18.11 (18.10 in the previous edition), the cross-sectional area of wiring has been aligned with Part 1;
in 18.11 (18.10 in the previous edition), the types of cables have been updated with alternative regional cables.
- Standard24 pagesEnglish and French languagesale 15% off
This part of IEC 62722 covers specific performance and environmental requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. Unless otherwise detailed, performance data covered under the scope of this document are for the luminaires in a condition representative of new manufacture, with any specified initial aging procedures completed. This document covers requirements for luminaires to support energy efficient use and responsible environmental management to the end of life. The object of this document is to provide a set of requirements which are considered to be generally applicable to most types of luminaires. Where additional performance requirements for specific types of light source are relevant, these are specified in the IEC 62722-2 series. The IEC 62722-2 series can also cover a wider scope of performance aspects appropriate to the particular light source technology. Semi-luminaires are not covered under the scope of this document. For some types of luminaires (e.g. decorative or household) the provision of performance data under the scope of this document is not appropriate.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60598-2-11:2013 specifies requirements for household aquarium luminaires incorporating electric light sources on supply voltages not exceeding 1 000 V. This second edition cancels and replaces the first edition published in 2005. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) Subclause 11.1, change of the scope to open the standard for all kinds of electrical light sources.
b) Subclause 11.4.2, change of the definition in order to clarify non-permanently attached aquarium luminaire.
c) Subclause 11.11.3, for indoor operated aquarium luminaire, change of the size of external cable to at least 0,75 mm2 instead of 1,0 mm2 in the former edition.
This publication is to be read in conjunction with IEC 60598-1:2008.
- Standard21 pagesEnglish and French languagesale 15% off
- Standard42 pagesEnglish and French languagesale 15% off
- Standard9 pagesEnglish and French languagesale 15% off
This part of IEC 60598 specifies requirements for emergency luminaires for use with electrical lamps on emergency power supplies not exceeding 1 000 V. This document does not cover the effects of non-emergency voltage reductions on luminaires incorporating high pressure discharge lamps. This document gives general requirements for emergency lighting equipment. In this document, the term "lamp" which also includes "light source(s)" where appropriate, is used.
- Standard46 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62722-1:2022 covers specific performance and environmental requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. Unless otherwise detailed, performance data covered under the scope of this document are for the luminaires in a condition representative of new manufacture, with any specified initial aging procedures completed. This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- The reference to and use of the measurement methods for non-active power consumption in accordance with IEC 63103 have been added.
- The pictograms of Annex C have been updated to represent modern light sources.
- Standard58 pagesEnglish languagesale 15% off
- Standard38 pagesEnglish and French languagesale 15% off
This Part 1 of IEC 60598 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this document cover: classification, marking, mechanical construction, electrical construction and photobiological safety.
- Amendment7 pagesEnglish languagesale 10% offe-Library read for1 day
This Part 1 of IEC 60598 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this document cover: classification, marking, mechanical construction, electrical construction and photobiological safety.
- Amendment7 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60598-2-20:2022 specifies requirements for lighting chains fitted with series, parallel or a combination of series/parallel connected light sources for use either indoors or outdoors on supply voltages not exceeding 250 V. This fifth edition cancels and replaces the fourth edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- specific provisions for temporarily installed protected lighting (TPL) chains have been added;
- new terms and definitions have been added.
- Standard71 pagesEnglish languagesale 15% off
- Standard46 pagesEnglish and French languagesale 15% off
IEC 60601-2-41:2021 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of SURGICAL LUMINAIRES and LUMINAIRES FOR DIAGNOSIS, hereafter referred to as ME EQUIPMENT.
If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant.
This particular standard does not apply to
– headlights;
– endoscopes, laparoscopes and their light sources, which are covered by IEC 60601-2-18;
– luminaires used in dentistry, which are covered by ISO 9680;
– luminaires for general purposes, which are covered by IEC 60598-2-1 and IEC 60598-2-4;
– luminaires dedicated to therapeutic purposes;
– special purpose lights with different conditions of use such as light sources intended solely for decontamination of air and surfaces, UV lights for dermatological diagnosis, slit lamps for ophthalmology, lights for surgical microscopes and lights for surgical navigation systems;
– lights connected to surgical instruments, such as luminous retractors;
– luminaires for emergency lighting, which are covered by IEC 60598-2-22.
SURGICAL LUMINAIRES and LUMINAIRES FOR DIAGNOSIS are medical devices and not general lighting equipment.
IEC 60601-2-41:2021 cancels and replaces the second edition published in 2009 and Amendment 1:2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) revised the statement of essential performance;
b) added exposure limits, test conditions, calculation methods and safety warnings related to photobiological hazards;
c) removed the terms “MINOR SURGICAL LUMINAIRES” and “MAJOR SURGICAL LUMINAIRES”;
d) added definitions of MAXIMUM ILLUMINANCE DISTANCE and REFERENCE DISTANCE and allowed MANUFACTURERS to measure some performance characteristics at the REFERENCE DISTANCE that they specify;
e) replaced the region of acceptable chromaticity in (x,y) colour space with a requirement for Du,v;
f) added a requirement for acceptable drift of the lighthead when attached to the suspension system;
g) added a requirement for fluid ingress protection;
h) revised Table 201.101 of IEC 60601-2-41:2009 and IEC 60601-2-41:2009/AMD1:2013 and moved it to Annex BB;
i) specified a new device for measuring SHADOW DILUTION in a simulated cavity;
j) specified test conditions for luminaires equipped with distance sensors.
- Standard63 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60534-4:2021 specifies the requirements for the inspection and routine testing of control valves manufactured in conformity with the other parts of IEC 60534. This document is applicable to valves with pressure ratings not exceeding Class 2500. The requirements for actuators apply only to pneumatic actuators. This document does not apply to the types of control valves where radioactive service, fire safety testing, or other hazardous service conditions are encountered. If a standard for hazardous service conflicts with the requirements of this document, the standard for hazardous service should take precedence.
- Standard78 pagesEnglish languagesale 15% off
- Standard50 pagesEnglish and French languagesale 15% off
IEC 60598-2-22:2021 specifies requirements for emergency luminaires for use with electrical lamps on emergency power supplies not exceeding 1 000 V. This fifth edition cancels and replaces the fourth edition published in 2014 and Amendment 1:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- update of requirements for rest mode and inhibiting mode;
- clarification of high temperature operation tests;
- introduction of new requirements for lithium batteries;
- introduction of new requirements for electric double layer capacitors (EDLCs);
- clarification of resistance to heat, fire and tracking;
- clarification of test facilities for self-contained luminaires;
- clarification of the test method for contrast measurements of exit signs.
- Standard119 pagesEnglish languagesale 15% off
- Standard78 pagesEnglish and French languagesale 15% off
To complete the text of EN 61995-1:2008/A1:2017 (PR=60113) with common modification for Europe and Annex ZZ for LVD.
- Amendment7 pagesEnglish languagesale 10% offe-Library read for1 day
No Scope available
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
No Scope available
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60598-2-1:2020 specifies requirements for fixed general purpose luminaires for use with electric light sources on supply voltages not exceeding 1 000 V.
This second edition cancels and replaces the first edition published in 1979 and Amendment 1:1987. This edition constitutes a technical revision.
This edition includes the following technical changes with respect to the previous edition (there are no major technical changes, see Annex A):
a) the scope has been modified to be in line with Part 1 to include all electric light sources,
b) references to Part 1 have been updated.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
2018-09-14 PeC: Cited under the LVD in C 326/02
20180129: BT decision D139/C142 for implementation dates
- Amendment8 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60598-2-1:2020 specifies requirements for fixed general purpose luminaires for use with electric light sources on supply voltages not exceeding 1 000 V. This second edition cancels and replaces the first edition published in 1979 and Amendment 1:1987. This edition constitutes a technical revision. This edition includes the following technical changes with respect to the previous edition (there are no major technical changes, see Annex A): a) the scope has been modified to be in line with Part 1 to include all electric light sources, b) references to Part 1 have been updated.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60598-1:2020 is available as IEC 60598-1:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60598-1:2020 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this document cover: classification, marking, mechanical construction, electrical construction and photobiological safety. This ninth edition cancels and replaces the eighth edition published in 2014 and Amendment 1:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- Revision of Clause 4.30, Fixing cover live parts of non-user replaceable light source;
- Subclause 4.24.2, Blue Light Hazard: removal of Risk Group 0;
- Subclause 5.2.16: additional requirements for AC mains appliance inlets related to IEC 61984;
- Addition of Subclause 3.3.25, UV protection of cable;
- Addition of Clause 4.34, Inclusion of EMF safety requirements (IEC 62493);
- Revision of the requirements for functional earth and protective earth;
- Addition of Clause 4.35, Protection against fast rotating parts;
- Revision of Clause 3.2, Rated voltage marking;
- Revision of Subclause 5.2.10, Cord anchorage;
- Revision of Annex G for touch current and protective conductor current test set-up;
- Addition of requirements for constant light output function and programmable current output;
- Revision of Subclause 8.2.3 c), touch voltage limits for interrupted DC voltage;
- Introduction of PELV;
- Introduction of Ethernet power supply connection for luminaires (PoE);
- Section 9, Introduction of IPX9;
- Addition of Subclause 3.3.26 for wall mounted luminaires;
- Revision of Annex D introducing alternative thermal tests for luminaires with ta marking higher than 25°C;
- Revision of Table 10.3 and Subclause 3.3.19 for protective conductor current limits;
- Track-mounted luminaires: cross reference to Annex A of IEC 60570:2003/AMD2:2019;
- Revision of Subclause 10.2.2, alternative DC electric strength test;
- Revision of Annex D for recessed luminaires;
- Subclause 4.12.5: revision of Table 4.2 for torque test on metal glands;
- Revision of use of bridging capacitors in luminaires;
- Revision of electrical connection to class III plugs.
- Standard239 pagesEnglish languagesale 10% offe-Library read for1 day
NEW!IEC 60598-2-4:2017 is available as IEC 60598-2-4:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60598-2-4:2017 specifies requirements for portable general purpose luminaires for indoor and/or outdoor use (e.g. garden use), other than handlamps, designed to be used with or incorporating electrical light sources on supply voltages not exceeding 250 V. This third edition cancels and replaces the second edition published in 1997. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - alignment with IEC 60598-1; - modification of the scope, classification and requirements to cover portable luminaires for both indoor and outdoor applications, by introducing the requirements already listed in IEC 60598-2-7; NOTE In this edition of IEC 60598-2-4 all requirements listed in IEC 60598-2-7 have been incorporated. As a consequence, IEC 60598-2-7 will be withdrawn after publication of this standard. - modification of the scope to cover all electrical light sources (it was previously limited to tungsten filament, tubular fluorescent and other discharge lamps); - introduction of the symbol for luminaires which are other than ordinary, but suitable for indoor applications only (e.g. luminaire using PVC cable); - modification in the detail of test to clarify that the stability test on an inclined plane (see 4.7.3) shall be carried out with the light source(s) in place; - modification of the minimum degree of protection against dust and moisture for portable luminaires for outdoor use from IPX3 to IPX4 (see 4.5.2); as a consequence, the requirements for cable entry position, as given in IEC 60598-2-7:1982, 7.6.3 were deleted as they are covered by IPX4; - modification of the requirements for the acceptance criteria of plug and socket outlet; - modification of the IP test requiring the most unfavourable of the overturned positions to cover all classes (and not only class II luminaires as in 7.13.1 of IEC 60598-2-7:1982).
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60598-2-17:2017 specifies requirements for stage, television, film and photographic studio luminaires (including spot and floodlighting projectors) for use outdoors and indoors, with electric light sources on supply voltages not exceeding 1 000 V. This second edition cancels and replaces the first edition published in 1984 and Amendement 2:1990. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) extension of the applicable scope from light source to electric light source and replacement of "tungsten filament, tubular fluorescent and other discharge lamps" with "electric light source" in 17.1. b) consideration of the fact that there are many LED luminaires with non-replaceable light source, and light source without a glass bulb, or with low operation temperature: the applicable scope of relevant clauses therefore only applies to replaceable light source luminaires with a glass bulb lamp, or with high surface temperature.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60598-1:2020 is available as IEC 60598-1:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60598-1:2020 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this document cover: classification, marking, mechanical construction, electrical construction and photobiological safety. This ninth edition cancels and replaces the eighth edition published in 2014 and Amendment 1:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Revision of Clause 4.30, Fixing cover live parts of non-user replaceable light source; - Subclause 4.24.2, Blue Light Hazard: removal of Risk Group 0; - Subclause 5.2.16: additional requirements for AC mains appliance inlets related to IEC 61984; - Addition of Subclause 3.3.25, UV protection of cable; - Addition of Clause 4.34, Inclusion of EMF safety requirements (IEC 62493); - Revision of the requirements for functional earth and protective earth; - Addition of Clause 4.35, Protection against fast rotating parts; - Revision of Clause 3.2, Rated voltage marking; - Revision of Subclause 5.2.10, Cord anchorage; - Revision of Annex G for touch current and protective conductor current test set-up; - Addition of requirements for constant light output function and programmable current output; - Revision of Subclause 8.2.3 c), touch voltage limits for interrupted DC voltage; - Introduction of PELV; - Introduction of Ethernet power supply connection for luminaires (PoE); - Section 9, Introduction of IPX9; - Addition of Subclause 3.3.26 for wall mounted luminaires; - Revision of Annex D introducing alternative thermal tests for luminaires with ta marking higher than 25°C; - Revision of Table 10.3 and Subclause 3.3.19 for protective conductor current limits; - Track-mounted luminaires: cross reference to Annex A of IEC 60570:2003/AMD2:2019; - Revision of Subclause 10.2.2, alternative DC electric strength test; - Revision of Annex D for recessed luminaires; - Subclause 4.12.5: revision of Table 4.2 for torque test on metal glands; - Revision of use of bridging capacitors in luminaires; - Revision of electrical connection to class III plugs.
- Standard239 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60598-2-23:2020 specifies requirements for extra-low-voltage lighting systems for ELV light sources, intended for ordinary interior use on supply voltages not exceeding 1 000 V. The luminaires, being connected in parallel, are supplied via freely suspended continuous supporting conductors or profiles, the current in the ELV part of the system not exceeding 25 A.
This second edition cancels and replaces the first edition published in 1996 and Amendment 1:2000. This edition constitutes a technical revision.
This edition includes the following technical changes with respect to the previous edition (there are no major technical changes, see Annex A):
a) The title has been modified to allow the inclusion of other light sources;
b) The scope has been updated to be aligned with the other parts of the IEC 60598-2 series and to include other light sources;
c) Normative references and the reference to transformer and controlgear standards have been updated;
d) The short circuit test (23.7.6.1 and 23.7.6.2) was removed and reference is now made to the same test in Part 1.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day