IEC 60669-2-3:2024 is available as IEC 60669-2-3:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60669-2-3:2024 applies to time-delay switches (hereinafter referred to as TDS) with a rated voltage not exceeding 440 V AC and a rated current not exceeding 63 A, intended for household and similar fixed electrical installations, either indoors or outdoors, operated by hand and/or by remote control. For the control circuit, the rated control voltage does not exceed 440 V AC or 220 V DC. This fourth edition cancels and replaces the third edition published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Revision of the present edition with reference to IEC 60669-1:2017 (Edition 4); b) Introduction of a revision to Annex E "Additional requirements and tests for switches intended to be used at a temperature lower than −5 °C".

  • Draft
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60669-2-2:2024 is available as IEC 60669-2-2:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60669-2-2:2024 applies to electromagnetic remote control switches (hereinafter referred to as electromagnetic RCS) with a rated voltage not exceeding 440 V AC and a rated current not exceeding 63 A, intended for household and similar fixed electrical installations, either indoors or outdoors. For the control circuit, the rated control voltage does not exceed 440 V AC or 220 V DC. This fourth edition cancels and replaces the third edition published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Revision of the present edition with reference to IEC 60669-1:2017 (Edition 4); b) Introduction of a revision to Annex E "Additional requirements and tests for switches intended to be used at a temperature lower than −5 °C".

  • Draft
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60669-2-4:2024 applies to manually operated general purpose isolating switches with a rated voltage not exceeding 440 V and a rated current not exceeding 125 A, intended for household and similar fixed electrical installations, either indoors or outdoors. This second edition cancels and replaces the first edition published in 2004. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) revision of the present edition with reference to the published IEC 60669-1:2017 Edition 4 with its amendments and references to clauses and tables; b) introducing the values for isolating switches with ratings from 6 A to 13 A; c) introducing a circuit motor load with a rated current not exceeding 10 A and a power factor not less than 0,6 in the scope; d) modification of Table 1 and Table 5.

  • Draft
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62626-1:2023 is available as IEC 62626-1:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 62626-1:2023 applies to enclosed switches-disconnectors with rated voltages up to 1 000 V AC for repair and maintenance work or cleaning work in load circuits. Devices within the scope of this document are switch-disconnectors in accordance with IEC 60947-3 with specific additional requirements. Enclosed switch-disconnectors in this document are suitable for isolation in accordance with the IEC 60947 series and are not equipped with means for remote control or automatic switching to avoid unexpected or accidental start. These devices are not used for operational switching, for example quick start and stop, jogging. This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) update of this document based on IEC 60947-1:2020.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62626-1:2023 is available as IEC 62626-1:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62626-1:2023 applies to enclosed switches-disconnectors with rated voltages up to 1 000 V AC for repair and maintenance work or cleaning work in load circuits. Devices within the scope of this document are switch-disconnectors in accordance with IEC 60947-3 with specific additional requirements. Enclosed switch-disconnectors in this document are suitable for isolation in accordance with the IEC 60947 series and are not equipped with means for remote control or automatic switching to avoid unexpected or accidental start. These devices are not used for operational switching, for example quick start and stop, jogging. This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) update of this document based on IEC 60947-1:2020.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document covers internal arc-fault control devices, hereinafter referred to as IACD, which
are intended to:
- detect internal arc-faults in low-voltage switchgear and controlgear assemblies, by
processing (at a minimum) the optical effect of an internal arc-fault, and
- operate mitigation device (either external or combined)
in order to minimize the effects of the internal arc-fault (see Figure 1).
For the purpose of this document the terms "light" or "optical" covers more than visible spectra.
They may cover also, for example, infrared or ultraviolet electromagnetic radiations (see
Annex D).
For combined-type IACD, this document is considered in addition to the relevant product
standard for internal arc-fault mitigation devices (IARD per IEC TS 63107:2020). Compliance
to the relevant product standard is mandatory and cannot be claimed by testing to this document
alone.
NOTE 1 Low-voltage switchgear and controlgear assemblies are usually described by IEC 61439 series.
[Figure 1]
Therefore, this document covers the following:
- internal arc-fault control device (stand-alone, multifunction or combined);
- one or more associated sensor(s) used to detect optical effect of the internal arc-fault;
- sensor(s), sensing another physical effect, to confirm the fault;
- associated or combined mitigation device.
An IACD is not intended to trigger under normal operation of low-voltage switchgear and
controlgear (i.e. absence of internal arc-fault), including normal arcing associated with
operation of disconnecting and switching devices.
This document only covers the following methods:
- optical detection of the light caused by an internal arc-fault;
- optional confirmation of internal arc-fault by line current measurement.
Many different conductive materials could be used in LV assemblies (e.g. steel, copper,
aluminium). Nevertheless, tests specified in this document are deemed to represent the most
critical and challenging conditions for arc-detection and cover all combinations of conductive
materials.
NOTE 2 Compared to other materials (e.g. steel, aluminium), copper leads to a lower optical radiation energy.
The rated voltage of the assembly in which an IACD is installed does not exceed 1 000 V AC.
Such devices are designed to be operated and maintained by skilled persons only.
This document does not cover:
- DC internal arc-fault detection and control;
- overcurrent relays;
- AFDD (arc-fault detection devices) as defined by IEC 62606;
- guidance on installation within assemblies;
NOTE 3 The integration of an IACD into an assembly is described in IEC TS 63107.
- use with additional measures needed for installation and operation within explosive
atmospheres. These are given in IEC 60079 series documents;
- requirements for embedded software and firmware design rules; for this subject, the
manufacturer is responsible for taking additional safety measures;
NOTE 4 IEC TR 63201 describes rules for firmware and embedded software development preventing errors in
software.
- cybersecurity aspects; for this subject, the manufacturer is responsible for taking additional
safety measures;
NOTE 5 See IEC TS 63208.
- mobile applications.
NOTE 6 Even when addressing internal arc-fault mitigation devices, this document does not supersede any other
relevant product standard (e.g. IEC 60947-2 or IEC 60947-9-1).
NOTE 7 DC arcing fault phenomena are under consideration. Further investigation is needed to comprehend DC
arcing phenomena and required sensing.

  • Standard
    90 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63180:2020 provides a methodology and test procedures to be able to declare and verify the detection area for motion detectors using passive infrared technology in electronic control devices and appliance switches, whether stand-alone (direct control of one or more applications) or as part of home and building electronic systems or building automation control systems (HBES/BACS) or similar.

  • Standard
    66 pages
    English language
    sale 15% off
  • Standard
    56 pages
    English and French language
    sale 15% off

IEC 60947-5-1:2024 applies to control circuit devices and switching elements intended for controlling, signalling, interlocking, etc., of switchgear and controlgear.
It applies to control circuit devices having a rated voltage not exceeding 1 000 V AC (at a frequency not exceeding 1 000 Hz) or 600 V DC.
This fifth edition cancels and replaces the fourth edition published in 2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) update of the scope structure and exclusions;
b) requirements for control circuits;
c) update of the normal service conditions (e.g. shock and vibration);
d) update of information and marking requirements including environmental information requirements referencing IEC TS 63058:2021;
e) update of the constructional requirements and the corresponding tests considering safety aspects (e.g. artificial optical radiation, security aspects, limited energy source, stored charge energy circuit);
f) update of the EMC requirements according to the generic documents;
g) new requirements for reed contact magnetic switches in Annex D;
h) requirements for class II circuit devices achieved by double or reinforced insulation in Annex F;
i) update of pull-out tests in Annex G;
j) information requirements for audible signalling device in Annex J;
k) insertion of new Annex O.

  • Standard
    136 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60947-3:2020 applies to switches, disconnectors, switch-disconnectors and fuse-combination units and their dedicated accessories to be used in distribution circuits and motor circuits of which the rated voltage does not exceed 1 000 V AC or 1 500 V DC. This fourth edition cancels and replaces the third edition published in 2008, Amendment 1:2012 and Amendment 2:2015. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- addition of critical load current tests for DC switches (see 9.3.9);
- addition of requirements for a conditional short-circuit rating for disconnectors, switches, and switch-disconnectors protected by circuit-breakers (see 9.3.7.2);
- addition of new categories for high-efficiency motors switching (see Annex A);
- addition of new Annex E for connection to aluminium conductors;
- addition of new Annex F for power losses measurement.
The contents of the corrigendum of October 2021 have been included in this copy.

  • Standard
    217 pages
    English language
    sale 15% off
  • Standard
    190 pages
    English and French language
    sale 15% off

IEC 60947-5-1:2024 applies to control circuit devices and switching elements intended for controlling, signalling, interlocking, etc., of switchgear and controlgear. It applies to control circuit devices having a rated voltage not exceeding 1 000 V AC (at a frequency not exceeding 1 000 Hz) or 600 V DC. This fifth edition cancels and replaces the fourth edition published in 2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) update of the scope structure and exclusions; b) requirements for control circuits; c) update of the normal service conditions (e.g. shock and vibration); d) update of information and marking requirements including environmental information requirements referencing IEC TS 63058:2021; e) update of the constructional requirements and the corresponding tests considering safety aspects (e.g. artificial optical radiation, security aspects, limited energy source, stored charge energy circuit); f) update of the EMC requirements according to the generic documents; g) new requirements for reed contact magnetic switches in Annex D; h) requirements for class II circuit devices achieved by double or reinforced insulation in Annex F; i) update of pull-out tests in Annex G; j) information requirements for audible signalling device in Annex J; k) insertion of new Annex O.

  • Standard
    136 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60669-2-1:2021 applies to electronic control devices, a general term to cover electronic switches, home and building electronic systems (HBES) / building automation and control systems (BACS) switches and electronic extension units.
It applies to electronic switches and to HBES/BACS switches, for alternating current (AC) only with a rated switching voltage not exceeding 250 V and a rated current not exceeding 16 A, intended for household and similar fixed electrical installations, either indoors or outdoors.
It also applies to electronic extension units with a rated supply voltage not exceeding 250 V AC and 120 V DC, such as sensors and push buttons.
This document also applies to electronic remote control switches (RCS) and electronic time delay switches (TDS). Particular requirements are given in Annex FF.
This fifth edition cancels and replaces the fourth edition published in 2002, Amendment 1:2008 and Amendment 2:2015. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) incorporation of the requirements for HBES switches, previously included in IEC 60669-2-5;
b) modification of 19.106, test and requirements for switches for LEDs;
c) general indication to cover electronic control devices;
d) test for looping through.

  • Standard
    1 page
    English and French language
    sale 15% off

IEC 60947-5-1:2024 applies to control circuit devices and switching elements intended for controlling, signalling, interlocking, etc., of switchgear and controlgear.
It applies to control circuit devices having a rated voltage not exceeding 1 000 V AC (at a frequency not exceeding 1 000 Hz) or 600 V DC.
This fifth edition cancels and replaces the fourth edition published in 2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) update of the scope structure and exclusions;
b) requirements for control circuits;
c) update of the normal service conditions (e.g. shock and vibration);
d) update of information and marking requirements including environmental information requirements referencing IEC TS 63058:2021;
e) update of the constructional requirements and the corresponding tests considering safety aspects (e.g. artificial optical radiation, security aspects, limited energy source, stored charge energy circuit);
f) update of the EMC requirements according to the generic documents;
g) new requirements for reed contact magnetic switches in Annex D;
h) requirements for class II circuit devices achieved by double or reinforced insulation in Annex F;
i) update of pull-out tests in Annex G;
j) information requirements for audible signalling device in Annex J;
k) insertion of new Annex O.

  • Standard
    263 pages
    English and French language
    sale 15% off

IEC 60669-2-4:2024 applies to manually operated general purpose isolating switches with a rated voltage not exceeding 440 V and a rated current not exceeding 125 A, intended for household and similar fixed electrical installations, either indoors or outdoors. This second edition cancels and replaces the first edition published in 2004. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) revision of the present edition with reference to the published IEC 60669-1:2017 Edition 4 with its amendments and references to clauses and tables;
b) introducing the values for isolating switches with ratings from 6 A to 13 A;
c) introducing a circuit motor load with a rated current not exceeding 10 A and a power factor not less than 0,6 in the scope;
d) modification of Table 1 and Table 5.

  • Standard
    209 pages
    English language
    sale 15% off
  • Standard
    70 pages
    English and French language
    sale 15% off

IEC 60669-2-3:2024 applies to time-delay switches (hereinafter referred to as TDS) with a rated voltage not exceeding 440 V AC and a rated current not exceeding 63 A, intended for household and similar fixed electrical installations, either indoors or outdoors, operated by hand and/or by remote control. For the control circuit, the rated control voltage does not exceed 440 V AC or 220 V DC. This fourth edition cancels and replaces the third edition published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) Revision of the present edition with reference to IEC 60669-1:2017 (Edition 4);
b) Introduction of a revision to Annex E "Additional requirements and tests for switches intended to be used at a temperature lower than −5 °C".

  • Standard
    66 pages
    English language
    sale 15% off
  • Standard
    173 pages
    English language
    sale 15% off
  • Standard
    42 pages
    English and French language
    sale 15% off

IEC 60669-2-2:2024 applies to electromagnetic remote control switches (hereinafter referred to as electromagnetic RCS) with a rated voltage not exceeding 440 V AC and a rated current not exceeding 63 A, intended for household and similar fixed electrical installations, either indoors or outdoors. For the control circuit, the rated control voltage does not exceed 440 V AC or 220 V DC. This fourth edition cancels and replaces the third edition published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) Revision of the present edition with reference to IEC 60669-1:2017 (Edition 4);
b) Introduction of a revision to Annex E "Additional requirements and tests for switches intended to be used at a temperature lower than −5 °C".

  • Standard
    66 pages
    English language
    sale 15% off
  • Standard
    175 pages
    English language
    sale 15% off
  • Standard
    42 pages
    English and French language
    sale 15% off

IEC 62626-1:2023 applies to enclosed switches-disconnectors with rated voltages up to 1 000 V AC for repair and maintenance work or cleaning work in load circuits. Devices within the scope of this document are switch-disconnectors in accordance with IEC 60947-3 with specific additional requirements. Enclosed switch-disconnectors in this document are suitable for isolation in accordance with the IEC 60947 series and are not equipped with means for remote control or automatic switching to avoid unexpected or accidental start. These devices are not used for operational switching, for example quick start and stop, jogging. This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) update of this document based on IEC 60947-1:2020.

  • Standard
    33 pages
    English language
    sale 15% off
  • Standard
    21 pages
    English and French language
    sale 15% off

This part of EN 60947applies to transfer switching equipment (TSE) to be used in power systems with interruption of the supply to the load during transfer, the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c.

  • Standard
    66 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This clause of Part 1 is completely replaced by the following:
This part of IEC 60669 applies to electronic control devices, a general term to cover electronic switches, home and building electronic systems (HBES) / building automation and control systems (BACS) switches and electronic extension units.
It applies to electronic switches and to HBES/BACS switches, for alternating current (AC) only with a rated switching voltage not exceeding 250 V and a rated current not exceeding 16 A, intended for household and similar fixed electrical installations, either indoors or outdoors.
It also applies to electronic extension units with a rated supply voltage not exceeding 250 V AC and 120 V DC, such as sensors and push buttons.
This document also applies to electronic remote control switches (RCS) and electronic time delay switches (TDS). Particular requirements are given in Annex FF.
Switches including only passive components such as resistors, capacitors, inductors, positive temperature coefficient (PTC) and negative temperature coefficient (NTC) components, varistors, printed wiring boards and connectors are not considered as electronic control devices.
This document also applies to electronic switches and HBES/BACS switches for the operation of lighting equipment circuits and the control of the brightness of lighting equipment (dimmers) as well as the control of the speed of motors (for example, those used in ventilating fans) and for other purposes (for example, heating controls).
The operation and/or control as mentioned above can be transmitted by an electronic signal via several media, for example, powerline (mains), twisted pair, optical fibre, radio frequency, infrared, etc. and are performed:
- intentionally by a person via an actuating member, a key, a card, etc., via a sensing
surface or a sensing unit, by means of touch, proximity, turn, optical, acoustic, thermal;
- by physical means, for example, light, temperature, humidity, time, wind velocity, presence
of people;
- by any other influence.
This document also applies to electronic control devices which include integrated radio receivers and transmitters.
This document covers only those requirements for mounting boxes which are necessary for the tests on the electronic control devices.
Requirements for general purpose mounting boxes are given in the relevant part, if any, of IEC 60670.
This document is not intended to cover devices falling within the scope of IEC 60730 (all parts).
Electronic control devices complying with this document are suitable for use at ambient temperature not normally exceeding 25 °C but occasionally reaching 35 °C with a lower limit of the ambient air temperature of −5 °C.
NOTE 1 For lower temperatures, see Annex E.
Functional safety aspects are not covered by this document. Functional safety requirements are covered by the standards of the controlled devices.
In locations where special conditions prevail, such as in ships, vehicles and the like and in hazardous locations, for example where explosions are liable to occur, special construction and/or additional requirements may be required.
This document is not intended to cover devices which are designed to be incorporated in appliances or are intended to be delivered together with a specific appliance and which are within the scope of IEC 60730 (all parts) or IEC 61058-1.
Examples of designs of electronic switches and HBES/BACS switches and functions are shown in Annex AA.
Additional requirements for electronic control devices using DLT-technology in accordance with IEC 62756-1 are given in Annex CC.
Electrical interface specification for phase-cut dimmer used in phase-cut dimmed lighting systems are given for information only in Annex EE.
NOTE 2 Electronic switches and HBES/BACS switches without a mechanical switch in the main circuit do not provide a "full off-state". Therefore, the circuit on the load side are to be considered to be live.

  • Standard
    139 pages
    English language
    sale 10% off
    e-Library read for
    1 day

To give requirements and tests for electronic control devices, a general term to cover electronic switches, HBES/BACS switches and electronic extension units.
It applies to electronic switches and to HBES/BACS switches, for alternating current (AC) only with a rated switching voltage not exceeding 250 V and a rated current not exceeding 16 A, intended for household and similar fixed electrical installations, either indoors or outdoors.
It also applies to electronic extension units with a rated supply voltage not exceeding 250 V AC and 120 V DC.
This Part of IEC 60669 also applies to electronic control devices which include integrated radio receivers and transmitters.

  • Amendment
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60934:2019 is available as IEC 60934:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60934:2019 is applicable to mechanical switching devices designed as "circuit‑breakers for equipment" (CBE) for household and similar applications. CBEs according to this document are intended to provide protection to circuits within electrical equipment including its components (e.g. motors, transformers, internal wiring). This document covers also CBEs applicable for protection of electrical equipment in case of undervoltage and/or overvoltage. This document also covers CBEs which are suitable for isolation. This fourth edition cancels and replaces the third edition published in 2000, Amendment 1:2007 and Amendment 2:2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) clarifications for type testing purposes.

  • Standard
    122 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This clause of Part 1 is completely replaced by the following: This part of IEC 60669 applies to electronic control devices, a general term to cover electronic switches, home and building electronic systems (HBES) / building automation and control systems (BACS) switches and electronic extension units. It applies to electronic switches and to HBES/BACS switches, for alternating current (AC) only with a rated switching voltage not exceeding 250 V and a rated current not exceeding 16 A, intended for household and similar fixed electrical installations, either indoors or outdoors. It also applies to electronic extension units with a rated supply voltage not exceeding 250 V AC and 120 V DC, such as sensors and push buttons. This document also applies to electronic remote control switches (RCS) and electronic time delay switches (TDS). Particular requirements are given in Annex FF. Switches including only passive components such as resistors, capacitors, inductors, positive temperature coefficient (PTC) and negative temperature coefficient (NTC) components, varistors, printed wiring boards and connectors are not considered as electronic control devices. This document also applies to electronic switches and HBES/BACS switches for the operation of lighting equipment circuits and the control of the brightness of lighting equipment (dimmers) as well as the control of the speed of motors (for example, those used in ventilating fans) and for other purposes (for example, heating controls). The operation and/or control as mentioned above can be transmitted by an electronic signal via several media, for example, powerline (mains), twisted pair, optical fibre, radio frequency, infrared, etc. and are performed: - intentionally by a person via an actuating member, a key, a card, etc., via a sensing surface or a sensing unit, by means of touch, proximity, turn, optical, acoustic, thermal; - by physical means, for example, light, temperature, humidity, time, wind velocity, presence of people; - by any other influence. This document also applies to electronic control devices which include integrated radio receivers and transmitters. This document covers only those requirements for mounting boxes which are necessary for the tests on the electronic control devices. Requirements for general purpose mounting boxes are given in the relevant part, if any, of IEC 60670. This document is not intended to cover devices falling within the scope of IEC 60730 (all parts). Electronic control devices complying with this document are suitable for use at ambient temperature not normally exceeding 25 °C but occasionally reaching 35 °C with a lower limit of the ambient air temperature of −5 °C. NOTE 1 For lower temperatures, see Annex E. Functional safety aspects are not covered by this document. Functional safety requirements are covered by the standards of the controlled devices. In locations where special conditions prevail, such as in ships, vehicles and the like and in hazardous locations, for example where explosions are liable to occur, special construction and/or additional requirements may be required. This document is not intended to cover devices which are designed to be incorporated in appliances or are intended to be delivered together with a specific appliance and which are within the scope of IEC 60730 (all parts) or IEC 61058-1. Examples of designs of electronic switches and HBES/BACS switches and functions are shown in Annex AA. Additional requirements for electronic control devices using DLT-technology in accordance with IEC 62756-1 are given in Annex CC. Electrical interface specification for phase-cut dimmer used in phase-cut dimmed lighting systems are given for information only in Annex EE. NOTE 2 Electronic switches and HBES/BACS switches without a mechanical switch in the main circuit do not provide a "full off-state". Therefore, the circuit on the load side are to be considered to be live.

  • Standard
    139 pages
    English language
    sale 10% off
    e-Library read for
    1 day

To give requirements and tests for electronic control devices, a general term to cover electronic switches, HBES/BACS switches and electronic extension units. It applies to electronic switches and to HBES/BACS switches, for alternating current (AC) only with a rated switching voltage not exceeding 250 V and a rated current not exceeding 16 A, intended for household and similar fixed electrical installations, either indoors or outdoors. It also applies to electronic extension units with a rated supply voltage not exceeding 250 V AC and 120 V DC. This Part of IEC 60669 also applies to electronic control devices which include integrated radio receivers and transmitters.

  • Amendment
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60947-9-1:2019 covers low-voltage arc quenching devices, hereinafter referred to as AQDs, which are intended to eliminate arc-faults in low-voltage assemblies (typically low-voltage switchgear and controlgear assemblies in accordance with the IEC 61439 series), by creating a lower impedance current path, to cause the arcing current to transfer to the new current path. This new current path is maintained until a short-circuit protection device (SCPD) interrupts the short-circuit current. AQDs are installed in low-voltage assemblies, connected to the main circuit, preferably as close as possible to all primary power sources. Their rated voltage does not exceed 1 000 V AC or 1 500 V DC.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN-IEC 60947-5-2 applies to inductive and capacitive proximity switches that sense the presence of metallic and/or non-metallic objects, ultrasonic proximity switches that sense the presence of sound reflecting objects, photoelectric proximity switches that sense the presence of objects and non-mechanical magnetic proximity switches that sense the presence of objects with a magnetic field. Products covered by the scope of this document are not subjected to defined behaviours under fault conditions. Proximity switches with defined behaviour are covered by IEC 60947-5-3 and have to fulfil additional requirements. These proximity switches are self-contained, have semiconductor switching element(s) and are intended to be connected to circuits, the rated voltage of which does not exceed 250 V 50 Hz/60 Hz AC RMS or 300 V DC. Examples of typical applications for in-scope products: - factory automation and machinery industry; - logistic and packaging industry; - conveyor belts, lifts; - process industry; - power plants. Special applications (e.g. corrosive atmosphere) can cause additional requirements. This document is not intended to cover proximity switches with analogue outputs. The object of this document is to state for proximity switches: - definitions; - classification; - characteristics; - product information; - normal service, mounting and transport conditions; - constructional and performance requirements; - tests to verify rated characteristics. Products covered by the scope of this document are expected to be selected, installed, and maintained by skilled personnel only.

  • Amendment
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN-IEC 60947-5-2 applies to inductive and capacitive proximity switches that sense the presence of metallic and/or non-metallic objects, ultrasonic proximity switches that sense the presence of sound reflecting objects, photoelectric proximity switches that sense the presence of objects and non-mechanical magnetic proximity switches that sense the presence of objects with a magnetic field. Products covered by the scope of this document are not subjected to defined behaviours under fault conditions. Proximity switches with defined behaviour are covered by IEC 60947-5-3 and have to fulfil additional requirements. These proximity switches are self-contained, have semiconductor switching element(s) and are intended to be connected to circuits, the rated voltage of which does not exceed 250 V 50 Hz/60 Hz AC RMS or 300 V DC. Examples of typical applications for in-scope products: - factory automation and machinery industry; - logistic and packaging industry; - conveyor belts, lifts; - process industry; - power plants. Special applications (e.g. corrosive atmosphere) can cause additional requirements. This document is not intended to cover proximity switches with analogue outputs. The object of this document is to state for proximity switches: - definitions; - classification; - characteristics; - product information; - normal service, mounting and transport conditions; - constructional and performance requirements; - tests to verify rated characteristics. Products covered by the scope of this document are expected to be selected, installed, and maintained by skilled personnel only.

  • Amendment
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document covers internal arc-fault control devices, hereinafter referred to as IACD, which are intended to: - detect internal arc-faults in low-voltage switchgear and controlgear assemblies, by processing (at a minimum) the optical effect of an internal arc-fault, and - operate mitigation device (either external or combined) in order to minimize the effects of the internal arc-fault (see Figure 1). For the purpose of this document the terms "light" or "optical" covers more than visible spectra. They may cover also, for example, infrared or ultraviolet electromagnetic radiations (see Annex D). For combined-type IACD, this document is considered in addition to the relevant product standard for internal arc-fault mitigation devices (IARD per IEC TS 63107:2020). Compliance to the relevant product standard is mandatory and cannot be claimed by testing to this document alone. NOTE 1 Low-voltage switchgear and controlgear assemblies are usually described by IEC 61439 series. [Figure 1] Therefore, this document covers the following: - internal arc-fault control device (stand-alone, multifunction or combined); - one or more associated sensor(s) used to detect optical effect of the internal arc-fault; - sensor(s), sensing another physical effect, to confirm the fault; - associated or combined mitigation device. An IACD is not intended to trigger under normal operation of low-voltage switchgear and controlgear (i.e. absence of internal arc-fault), including normal arcing associated with operation of disconnecting and switching devices. This document only covers the following methods: - optical detection of the light caused by an internal arc-fault; - optional confirmation of internal arc-fault by line current measurement. Many different conductive materials could be used in LV assemblies (e.g. steel, copper, aluminium). Nevertheless, tests specified in this document are deemed to represent the most critical and challenging conditions for arc-detection and cover all combinations of conductive materials. NOTE 2 Compared to other materials (e.g. steel, aluminium), copper leads to a lower optical radiation energy. The rated voltage of the assembly in which an IACD is installed does not exceed 1 000 V AC. Such devices are designed to be operated and maintained by skilled persons only. This document does not cover: - DC internal arc-fault detection and control; - overcurrent relays; - AFDD (arc-fault detection devices) as defined by IEC 62606; - guidance on installation within assemblies; NOTE 3 The integration of an IACD into an assembly is described in IEC TS 63107. - use with additional measures needed for installation and operation within explosive atmospheres. These are given in IEC 60079 series documents; - requirements for embedded software and firmware design rules; for this subject, the manufacturer is responsible for taking additional safety measures; NOTE 4 IEC TR 63201 describes rules for firmware and embedded software development preventing errors in software. - cybersecurity aspects; for this subject, the manufacturer is responsible for taking additional safety measures; NOTE 5 See IEC TS 63208. - mobile applications. NOTE 6 Even when addressing internal arc-fault mitigation devices, this document does not supersede any other relevant product standard (e.g. IEC 60947-2 or IEC 60947-9-1). NOTE 7 DC arcing fault phenomena are under consideration. Further investigation is needed to comprehend DC arcing phenomena and required sensing.

  • Standard
    90 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Clause 1 of IEC 61058-1:2016 is applicable except as follows. Addition: This part of IEC 61058 is a subset based on IEC 61058-1. The clauses outlined below are intended to address the specific requirements for switches incorporated into or integrated with electric motor-operated hand-held tools, transportable tools and lawn and garden machinery. This document is intended for switches with an ambient temperature up to and including 55 °C. Switches tested according to IEC 61058-1 are considered to comply with this document and additional testing is not required provided ratings, loads, and endurance are correct. NOTE This document takes into account the fact that tests are conducted as part of the end-product evaluation (e.g. products tested according to the IEC 60745 and IEC 62841 series, and lawn and gardening equipment tested according to the IEC 60335 series), and that tests are not conducted on the component switch.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 60947applies to transfer switching equipment (TSE) to be used in power systems with interruption of the supply to the load during transfer, the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c.

  • Standard
    66 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to control and protective switching devices (or equipment) (CPS), the main contacts of which are intended to be connected to circuits of rated voltage not exceeding 1 000 V a.c. or 1 500 V d.c. CPSs are intended to provide both protective and control functions for circuits and are operated otherwise than by hand. They may also fulfil additional functions, such as isolation.

  • Standard
    116 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61058-2-5:2018 is available as IEC 61058-2-5:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 61058-2-5:2018 applies to change-over selectors (mechanical or electronic) for appliances actuated by hand, by foot or by other human activity, to operate or control electrical appliances and other equipment for household or similar purposes with a rated voltage not exceeding 480 V and a rated current not exceeding 63 A. This third edition cancels and replaces the second edition published in 2010 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- updated references due to new structure of IEC 61058-1;
- changes on conducting the heating test due to the corresponding changes in IEC 61058-1.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61058-2-1:2018 applies to cord switches (mechanical or electronic) for appliances actuated by hand, by foot or by other human activity, to operate or control electrical appliances and other equipment for household or similar purposes with a rated voltage not exceeding 250 V and a rated current not exceeding 16 A.
This third edition cancels and replaces the second edition published in 2010 and constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
Overall format to support IEC 61058-1, IEC 61058-1-1, IEC 61058-1-2, and the heating tests.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61058-2-4:2018 is available as IEC 61058-2-4:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 61058-2-4:2018 applies to independently mounted switches for appliances (mechanical or electronic) actuated by hand, by foot or by other human activity, to operate or control electrical appliances and other equipment for household or similar purposes with a rated voltage not exceeding 480 V and a rated current not exceeding 63 A. This second edition cancels and replaces the first edition published in 1995 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- overall format modified to support the revised structure of the series;
- Annexes K and M have been included as an integral part of this document;
- Annex L has been included for information purposes only.
This document is to be used in conjunction with IEC 61058-1:2016.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61058-1:2016 is available as IEC 61058-1:2016 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61058-1:2016 applies to switches for appliances. The switches are intended to control electrical appliances and other equipment for household or similar purposes with a rated voltage not exceeding 480 V and a rated current not exceeding 63 A. This fourth edition cancels and replaces the third edition published in 2000, Amendment 1:2001 and Amendment 2:2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) requirements for mechanical switches are now given in IEC 61058-1-1; b) requirements for electronic switches are now given in IEC 61058-1-2.

  • Standard
    128 pages
    English language
    sale 10% off
    e-Library read for
    1 day