IEC 60947-4-2:2020 applies to semiconductor motor controllers, starters and soft-starters which can include a series mechanical switching device, intended to be connected to circuits the rated voltage of which does not exceed 1 000 V AC.
This fourth edition cancels and replaces the third edition published in 2011. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- scope exclusions;
- editorial correction of notes and hanging paragraphs;
- reference to IEC 62683-1;
- safety aspects related to:
- general aspects;
- limited energy circuits;
- electronic circuits;
- mention of dedicated wiring accessories;
- power consumption measurement;
- alignment to IEC 60947-1:2020.

  • Standard
    228 pages
    English language
    sale 15% off
  • Standard
    230 pages
    English and French language
    sale 15% off

IEC 60947-2:2024 applies to circuit-breakers, intended to be installed and operated by instructed or skilled persons, the main contacts of which are intended to be connected to circuits, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC; it also contains additional requirements for integrally fused circuit-breakers.
This document also applies to circuit-breakers with ratings at or below 1 000 V AC, additionally having one or more ratings above 1 000 V AC but not exceeding 1 500 V AC.
This sixth edition cancels and replaces the fifth edition published in 2016 and its Amendment 1: 2019. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) suitability for isolation (see Clause 1);
b) removal of the classification according to the interrupting medium, according to the design, according to the suitability for isolation (see Clause 4);
c) adjustment of current settings with an external device connectable to the release (see 5.7.3);
d) requirements for circuits with protective separation (see 8.2.3.8);
e) additional tests for ground-fault overcurrent releases (see 9.3.4.2.5);
f) additional tests concerning dielectric properties in tripped position (see 9.3.4.3);
g) use of DC voltage for dielectric tests (see 9.3.4.6.2 and 9.4.6);
h) tests of individual pole breaking capacity under phase-to-neutral AC voltage (see 9.3.11);
i) improvement of measurement of power loss in Annex G;
j) changes in EMC tests (see Annex J);
k) introduction of CBI class W in Annex L.

  • Standard
    565 pages
    English and French language
    sale 15% off

IEC 60947-1:2020 applies, when required by the relevant product standard, to low-voltage switchgear and controlgear hereinafter referred to as "equipment" or “device” and intended to be connected to circuits, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC.
This document states the general rules and common safety requirements for low-voltage switchgear and controlgear, including:
- definitions;
- characteristics;
- information supplied with the equipment;
- normal service, mounting and transport conditions, decommissioning and dismantling;
- constructional and performance requirements;
- verification of characteristics and performance;
- energy efficiency aspects (see Annex V);
- environmental aspects.
This sixth edition cancels and replaces the fifth edition published in 2007, Amendment 1:2010 and Amendment 2:2014. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
– DC values testing improvement;
– update of EMC tests;
– Annex B deletion;
– update of requirements for environmental tests (Table Q.1);
– improvement of Annex R (new examples);
– deletion of digital input Type 2, and introduction of Type 3 in Annex S;
– example for materials declaration (Annex W);
– new Annex X (co-ordination between short-circuit protective devices associated in the same circuit) created.
The contents of the corrigendum of December 2022 have been included in this copy.

  • Standard
    3 pages
    English and French language
    sale 15% off

IEC 60947-5-7:2024 states the requirements for proximity devices that correspond to the scope of IEC 60947-5-2:2019 with analog output (PDAO) and/or a digital output to transmit a corresponding digital value representing the detected sensing input. These devices can provide additional parameters.
This second edition cancels and replaces the first edition published in 2003. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) New structure;
b) Update and expansion of definitions on analog output properties;
c) Expanded performance requirements on analog output;
d) Update and new normative references;
e) Update of EMC requirements;
f) Harmonization with IEC 62828 series;
g) Harmonization with IEC 62683 and IEC 61987 definitions;
h) Harmonization with IEC 61131-2 requirements;
i) Update of the Annex A (former Annex G), Example of the determination of the conformity;
j) New Annex B, Overview tests and influence quantities;
k) New Annex C, Additional requirements for proximity switches with analog output incorporating a built-in communication interface complying with IEC 61131-9;
l) New Annex D, Main characteristics for proximity devices with analog output.

  • Standard
    96 pages
    English and French language
    sale 15% off

IEC 60947-5-1:2024 applies to control circuit devices and switching elements intended for controlling, signalling, interlocking, etc., of switchgear and controlgear.
It applies to control circuit devices having a rated voltage not exceeding 1 000 V AC (at a frequency not exceeding 1 000 Hz) or 600 V DC.
This fifth edition cancels and replaces the fourth edition published in 2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) update of the scope structure and exclusions;
b) requirements for control circuits;
c) update of the normal service conditions (e.g. shock and vibration);
d) update of information and marking requirements including environmental information requirements referencing IEC TS 63058:2021;
e) update of the constructional requirements and the corresponding tests considering safety aspects (e.g. artificial optical radiation, security aspects, limited energy source, stored charge energy circuit);
f) update of the EMC requirements according to the generic documents;
g) new requirements for reed contact magnetic switches in Annex D;
h) requirements for class II circuit devices achieved by double or reinforced insulation in Annex F;
i) update of pull-out tests in Annex G;
j) information requirements for audible signalling device in Annex J;
k) insertion of new Annex O.

  • Standard
    263 pages
    English and French language
    sale 15% off

IEC 60947-4-1:2023 is applicable to the following equipment:
- electromechanical contactors and starters including motor protective switching devices (MPSD and IMPSD);
- actuators of contactor relays;
- contacts dedicated exclusively to the coil circuit of the contactor or the contactor relay;
- dedicated accessories (e.g. dedicated wiring, dedicated latch accessory);
intended to be connected to distribution circuits, motors circuits and other load circuits, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC.
This fifth edition cancels and replaces the fourth edition published in 2018. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) objective in the scope;
b) instantaneous only motor protective switching device IMPSD (3.5.33);
c) kinds of equipment (5.2.1);
d) methods of overload protection of motors (5.2.6);
e) adoption of the AC-7d from IEC 61095:2023 (in 5.4.2);
f) separately mounted overload relay of a starter (in 5.7.3 b));
g) starter and contactor suitable for use downstream to basic drive module (6.1.2 w));
h) reference to IEC TS 63058 for environmental aspects (in 6.4);
i) wiring subject to movement (in 8.1.3);
j) use of voltage transient limiting device (8.1.18);
k) accessible parts subject to temperature limits (in 8.2.2.3);
l) reference to Annex X of IEC 60947-1:2020 for the co-ordination of MPSD with SCPD (8.2.5.4);
m) reference to IEC TR 63216 with different EMC environments (8.3.1);
n) reference to IEC TR 63201 for the embedded software design (8.4);
o) reference to IEC TS 63208 for cybersecurity aspects (8.5);
p) update and completion of the measurement method of the power consumption of the electromagnet (9.3.3.2.1.2);
q) update of Annex C including rational about AC-3e;
r) determination of the critical load current for photovoltaic applications (M.8.7).

  • Standard
    385 pages
    English and French language
    sale 15% off

IEC 62626-1:2023 applies to enclosed switches-disconnectors with rated voltages up to 1 000 V AC for repair and maintenance work or cleaning work in load circuits. Devices within the scope of this document are switch-disconnectors in accordance with IEC 60947-3 with specific additional requirements. Enclosed switch-disconnectors in this document are suitable for isolation in accordance with the IEC 60947 series and are not equipped with means for remote control or automatic switching to avoid unexpected or accidental start. These devices are not used for operational switching, for example quick start and stop, jogging. This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) update of this document based on IEC 60947-1:2020.

  • Standard
    33 pages
    English language
    sale 15% off
  • Standard
    21 pages
    English and French language
    sale 15% off

IEC 61095:2023 applies to electromechanical air break contactors for household and similar purposes provided with main contacts intended to be connected to circuits the rated voltage of which does not exceed 440 V AC (between phases) with rated operational currents less than or equal to 63 A for utilization category AC-7a, and 32 A for utilization categories AC‑7b, AC‑7c and AC-7d (expressed in rated power), and rated conditional short-circuit current less than or equal to 6 kA. This third edition cancels and replaces the second edition published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) addition of requirements for screwless terminals;
b) addition of requirements for the switching of LED lamps. Contactors for domestic and similar applications can be used for controlling lighting loads which is increasingly using LED lamp technology. A specific category for contactors is created: AC-7d. Requirements and tests are added to cover this market development, mainly for making and breaking and conventional operational performance;
c) addition of requirements for contactors with electronically controlled electromagnet. Household contactors with electronically controlled electromagnet are available for years on the market. To fully cover such device, requirements and tests are added, dealing mainly with operating limits, behaviour in abnormal conditions, breakdown of components, EMC tests, etc.
d) embedded software. More and more contactors are incorporating electronic circuits with embedded software. A reference is provided to guide the design of the software.

  • Standard
    435 pages
    English language
    sale 15% off
  • Standard
    284 pages
    English and French language
    sale 15% off

IEC TR 63434:2023 is intended to provide awareness about partial discharge phenomena. This document gives guidance for some conditions when partial discharge can occur in low voltage switchgear and controlgear connected to networks of up to 1 000 V AC. Internal operational voltages can exceed these values. This document gives guidance on the design of conductors and dimensioning of insulation exposed to electrical fields.
This document explains the partial discharge phenomena considering electrical field stress, type of insulation material and other construction parameters, such as the voltage, frequency, temperature, humidity and the distances within the device.

  • Technical report
    40 pages
    English language
    sale 15% off

IEC TS 60947-7-5:2021 specifies requirements for terminal blocks with screw-type or screwless-type clamping units primarily intended for industrial or similar use and to be fixed to a support to provide electrical and mechanical connection. This document can be used for terminal blocks for connection between aluminium conductors or aluminium to copper conductors. It applies to terminal blocks intended to connect round conductors, with or without special preparation, having a cross-section between 2,5 mm2 and 300 mm2 (AWG 12 to 600 kcmil), intended to be used in circuits of a rated voltage not exceeding 1 000 V AC (up to 1 000 Hz) or 1 500 V DC.

  • Technical specification
    61 pages
    English and French language
    sale 15% off

IEC 60947-8:2021 specifies requirements for control units, which control a switching device in response to the PTC thermistors incorporated in rotating electrical machines and the industrial application.
This second edition cancels and replaces the first edition published in 2003, Amendment 1:2006 and Amendment 2:2011. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
safety aspects related to:
general aspects;
limited energy circuits;
electronic circuits;
alignment to IEC 60947-1:2020;
wire break detection function;
the term detector is replaced by thermistor;
reference to IEC 60738-1-4.

  • Standard
    82 pages
    English and French language
    sale 15% off

IEC 60947-9-2:2021 covers internal arc-fault control devices, hereinafter referred to as IACD, which are intended to:
– detect internal arc-faults in low-voltage switchgear and controlgear assemblies, by processing (at a minimum) the optical effect of an internal arc-fault, and
– operate mitigation device (either external or combined) in order to minimize the effects of the internal arc-fault.

  • Standard
    175 pages
    English and French language
    sale 15% off

IEC 60947-6-1:2021 applies to transfer switching equipment (TSE), to be used in power systems for ensuring the continuity of the supply and allowing the energy management of the installation, by transferring a load between power supply sources, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC.
This third edition cancels and replaces the second edition published in 2005, and its Amendment 1:2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
– clarification of scope and object;
– clarification of terms and definitions;
– removal of unnecessary definitions;
– modification of characteristics;
– modification of utilization categories definitions;
– introduction of new markings requirements;
– addition of new requirements for clearances and creepage distances;
– addition of new requirements and tests for mechanical and electrical interlocks;
– clarification of transfer sequences;
– modification of requirements for rated short-time withstand currents;
– modification of new requirements for electromagnetic compatibility;
– clarification of performance requirements for CB type TSE, in alignment with requirements stated in IEC 60947-2;
– addition of new test sequence V: Critical load current performance of equipment with DC ratings.

  • Standard
    121 pages
    English and French language
    sale 15% off

IEC 60947-6-2:2020 This document applies to control and protective switching devices (or equipment) (CPS), the main contacts of which are intended to be connected to circuits of rated voltage not exceeding 1 000 V AC or 1 500 V DC.
It covers control and protective switching device (CPS):
- which provides protective and control functions for circuits and motors;
- where its control function is operated exclusively otherwise than by hand;
- which provides continuity of service after over-current conditions; and
- which can have additional functions, such as isolation or communication.
This third edition cancels and replaces the second edition published in 2002 and its Amendment 1:2007. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- editorial changes according to ISO/IEC directives Part 2,
- alignments with IEC 60947-1:2020:
- markings ("s", "sol", "r" or "f");
- constructional requirements including material requirements;
- requirements for screwless terminals;
- measurement method of the pole impedance;
- EMC requirement and testing;
- procedure to determine data for electromechanical CPS’s used in functional safety applications;
harmonisation with IEC 60947-2:2016:
- operation tests of under-voltage relays and shunt releases;
- CPS for IT systems (Annex G);
- coordination with other short-circuit protective devices;
alignments with IEC 60947-4-1:2018:
- test at the rated conditional short-circuit current Iq of protected switching devices;
- short-circuit tests harmonisation with North America;
- reliability data for functional safety applications (new Annex K);
- safety aspects related to electronic circuits and protective impedance (new Annex N);
- introduction of provisions covering the impact of higher locked rotor current to achieve high efficiency class;
- mention of dedicated wiring accessories;
- definitions and measurement method of the power consumption of the control circuit during holding and pick-up operations;
- load monitoring indicators (new Annex M).
The contents of the corrigenda of December 2021 and June 2023 have been included in this copy.

  • Standard
    225 pages
    English and French language
    sale 15% off

IEC 60947-5-8:2020 specifies requirements for three-position enabling switches. These switches are used as components of enabling devices to provide signals that,
- when activated, allow machine operation to be initiated by a separate start control, and
- when de-activated,
-- initiate a stop function, and
-- prevent initiation of machine operation.
This second edition cancels and replaces the first edition published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- due to the increasing range of useful applications of three-position enabling switches, note of scope, operational characteristics and tests are reviewed;
- figures for example of devices incorporating enabling switch are added in Annex A;
- new Annex B for procedure to determine reliability data for the switch used in functional safety applications is added.

  • Standard
    77 pages
    English language
    sale 15% off
  • Standard
    50 pages
    English and French language
    sale 15% off

IEC 60947-4-3:2020(E) applies to semiconductor controllers and semiconductor contactors for non-motor load intended to be connected to circuits, the rated voltage of which does not exceed 1 000 V AC.
It covers their use:
– for operations of changing the state of AC electric circuits between the ON-state and the OFF-state;
– with or without bypass switching devices;
– as controller, for reducing the amplitude of the RMS AC voltage.
This third edition cancels and replaces the second edition published in 2014. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) scope exclusions;
b) editorial correction of notes and hanging paragraphs;
c) safety aspects related to:
- general aspects;
- limited energy circuits;
- electronic circuits;
d) mention of dedicated wiring accessories;
e) power consumption measurement;
f) alignment to IEC 60947-1:2020;
g) alignment with IEC 60947-4-2 when appropriate.

  • Standard
    88 pages
    English language
    sale 15% off

IEC 60947-3:2020 applies to switches, disconnectors, switch-disconnectors and fuse-combination units and their dedicated accessories to be used in distribution circuits and motor circuits of which the rated voltage does not exceed 1 000 V AC or 1 500 V DC.
This fourth edition cancels and replaces the third edition published in 2008, Amendment 1:2012 and Amendment 2:2015. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
addition of critical load current tests for DC switches (see 9.3.9);
addition of requirements for a conditional short-circuit rating for disconnectors, switches, and switch-disconnectors protected by circuit-breakers (see 9.3.7.2);
addition of new categories for high-efficiency motors switching (see Annex A);
addition of new Annex E for connection to aluminium conductors;
addition of new Annex F for power losses measurement.  The contents of the corrigendum of October 2021 have been included in this copy.

  • Standard
    190 pages
    English and French language
    sale 15% off

IEC 60947-1:2020 applies, when required by the relevant product standard, to low-voltage switchgear and controlgear hereinafter referred to as "equipment" or “device” and intended to be connected to circuits, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC.
This document states the general rules and common safety requirements for low-voltage switchgear and controlgear, including:
- definitions;
- characteristics;
- information supplied with the equipment;
- normal service, mounting and transport conditions, decommissioning and dismantling;
- constructional and performance requirements;
- verification of characteristics and performance;
- energy efficiency aspects (see Annex V);
- environmental aspects.
This sixth edition cancels and replaces the fifth edition published in 2007, Amendment 1:2010 and Amendment 2:2014. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
– DC values testing improvement;
– update of EMC tests;
– Annex B deletion;
– update of requirements for environmental tests (Table Q.1);
– improvement of Annex R (new examples);
– deletion of digital input Type 2, and introduction of Type 3 in Annex S;
– example for materials declaration (Annex W);
– new Annex X (co-ordination between short-circuit protective devices associated in the same circuit) created.
The contents of the corrigendum of December 2022 and April 2024 have been included in this copy.

  • Standard
    577 pages
    English and French language
    sale 15% off

IEC TS 63208:2020 applies to the security related main functions of switchgear and controlgear during the whole lifecycle of the equipment. It is applicable to wired and wireless data communication means and the physical accessibility to the equipment, within its limits of environmental conditions.
This document is intended to develop awareness about security aspects and provides recommendations and requirements on the appropriate countermeasures against vulnerability to threats.

  • Technical specification
    46 pages
    English language
    sale 15% off

IEC TR 63216:2019 is to define homogeneous categories for the electromagnetic environments in order to harmonize as far as practicable all general rules and product standard requirements of electromagnetic compatibility (EMC), applicable to low-voltage switchgear, controlgear and their assemblies with built-in electronic circuits.
This document also addresses incorporated radiocommunication functions.
The typical application environments for such equipment include the electrical distribution in infrastructure, commercial and industrial buildings and the control systems of machinery, including motor-driven systems.
The primary intention of EMC requirements is to ensure the safe and reliable operation of the equipment, as well as the communication efficiency of the radiocommunication equipment within their intended environments.

  • Technical report
    32 pages
    English language
    sale 15% off

IEC 60947-5-2:2019 applies to inductive and capacitive proximity switches that sense the presence of metallic and/or non-metallic objects, ultrasonic proximity switches that sense the presence of sound reflecting objects, photoelectric proximity switches that sense the presence of objects and non-mechanical magnetic proximity switches that sense the presence of objects with a magnetic field.
This fourth edition cancels and replaces the third edition published in 2007 and Amendment 1:2012. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
update of the scope;
adaptation and update of the construction requirements according to IEC Guide 116 (e.g. material requirements, artificial optical radiation, instruction requirements, hot surface, unattended operation, foreseeable misuse…);
modification of the specifications concerning the sensing range and operating distance;
new definitions for photoelectric proximity switch type D with background suppression;
integration of the requirements and test procedures of photoelectric proximity switch type D with background suppression;
update of EMC requirements in Table 9 and Table 10;
integration of environmental information requirements and environmental condition by referencing Annexes O, W and Q of IEC 60947-1:2007, IEC 60947-1:2007/AMD1:2010 and IEC 60947-1:2007/AMD2:2014;
modification of impulse withstand voltage test (5.3.1.3, 9.3.3.4.5);
modification of the references in the (normative) standard body to the (informative) Annex A;
major update of Annex A (definitions update, new dimensions and shapes);
update of C.9.1.1;
update of Annex D in order to consider new connector types and normative references;
update of Annex F (additional symbols for photoelectric proximity switches).

  • Standard
    262 pages
    English and French language
    sale 15% off

IEC TR 63201:2019(E) provides information, and recommended minimum requirements related to embedded software supporting the main functions of switchgear and controlgear during the whole lifecycle of the equipment. It includes also the parameterization aspects and basics about secure coding standards.

  • Technical report
    27 pages
    English language
    sale 15% off

IEC 62026-1:2019 applies to interfaces between low-voltage switchgear, controlgear, and controllers (e.g. programmable controllers, personal computers, etc.). This document does not apply to higher level industrial communication networks that have become known as fieldbuses and are considered by IEC subcommittee 65C. This third edition cancels and replaces the second edition published in 2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) additional requirements for safety information and instructions, including the measures to be taken, if any, for achieving EMC compliance;
b) EMC immunity requirements aligned with current IEC 61000-6 series of standards. Radiated radio-frequency electromagnetic fields test level increased to 6 GHz;
c) EMC emissions requirements aligned with current CISPR 11 publication.

  • Standard
    42 pages
    English language
    sale 15% off
  • Standard
    28 pages
    English and French language
    sale 15% off

IEC 60947-7-4:2019 specifies requirements for PCB terminal blocks primarily intended for industrial or similar use. Mounting and fixing on the printed circuit board is made by soldering, press-in or equivalent methods to provide electrical and mechanical connection between copper conductors and the printed circuit board. This document applies to PCB terminal blocks intended to connect copper conductors, with or without special preparation, having a cross-section between 0,08 mm2 and 300 mm2 (AWG 28-600 kcmil), intended to be used in circuits of a rated voltage not exceeding 1 000 V AC up to 1 000 Hz or 1 500 V DC. This second edition cancels and replaces the first edition published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) additional test for PCB terminal blocks with clamping units, where contact pressure is transmitted through insulating materials;
b) tightening torques for screws now given in Table 4 of this document (previously given in Table 4 of IEC 60947-1:2007); tightening torques added for an additional type of screw;
c) new criteria for verification of contact resistance introduced;
d) clarification in the description of the temperature-rise test (current-temperature derating); corrections in the test sequence according to Figure 4.

  • Standard
    107 pages
    English language
    sale 15% off
  • Standard
    71 pages
    English and French language
    sale 15% off

IEC 60947-9-1:2019 covers low-voltage arc quenching devices, hereinafter referred to as AQDs, which are intended to eliminate arc-faults in low-voltage assemblies (typically low-voltage switchgear and controlgear assemblies in accordance with the IEC 61439 series), by creating a lower impedance current path, to cause the arcing current to transfer to the new current path. This new current path is maintained until a short-circuit protection device (SCPD) interrupts the short-circuit current.
AQDs are installed in low-voltage assemblies, connected to the main circuit, preferably as close as possible to all primary power sources.
Their rated voltage does not exceed 1 000 V AC or 1 500 V DC.

  • Standard
    37 pages
    English and French language
    sale 15% off

IEC 60947-4-1:2018 is applicable to the following equipment:
- electromechanical contactors and starters including motor protective switching device (MPSD);
- actuators of contactor relays;
- contacts dedicated exclusively to the coil circuit of this contactor or this contactor relay;
- dedicated accessories (e.g. dedicated wiring, dedicated latch accessory);
intended to be connected to distribution circuits, motors circuits and other load circuits, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC. This fourth edition cancels and replaces the third edition published in 2009 and its Amendment 1:2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- Scope structure and exclusions
- Editorial correction of notes and hanging paragraphs
- Reference to IEC 62683-1
- Motor protective switching device (MPSD) with its requirements
- Safety aspects related to:
- General aspects;
- Limited energy circuits;
- Electronic circuits;
- Assessment procedure for electromechanical overload protection used in safety -applications (new Annex L)
- Introduction of provisions covering the impact of higher locked rotor current to achieve high efficiency class
- Mention of dedicated wiring accessories
- Pickup power measurement
- Alignment to IEC 60947-1:2007, IEC 60947-1:2007/AMD1:2010, and IEC 60947‑1:2007/AMD2:2014
- Direct current requirements for covering photovoltaic application (new Annex M)
- Load monitoring indicators (new Annex O)
- Short-circuit breaking tests of MPSD (new Annex P)
- Co-ordination under short-circuit conditions between a MPSD and another short-circuit protective device associated in the same circuit (new Annex Q).
The contents of the interpretation sheet of March 2020, the corrigendum 1 of April 2020 and the corrigendum 2 of April 2021 have been included in this copy.

  • Standard
    586 pages
    English language
    sale 15% off
  • Standard
    371 pages
    English and French language
    sale 15% off

IEC 60715:2017 specifies dimensional and functional requirements for the compatible mounting of switchgear, controlgear and accessories on some types of rails.
This second edition cancels and replaces the first edition published in 1981 and Amendment 1:1995. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) the electrical function of the rail for protective earthing is covered by the relevant product standard.
b) the document has been editorially updated to bring it into compliance with the ISO/IEC Directives, Part 2:2016, and drawings have been updated to bring them in compliance with ISO tolerancing and drawing standards.
It has the status of a horizontal standard in accordance with IEC Guide 108.

  • Standard
    56 pages
    English and French language
    sale 15% off

IEC TR 63054:2017(E) applies to the fire risk analysis of low-voltage switchgear and controlgear (hereinafter referred to as "equipment") referring to the IEC 60947 relevant publications, where the following applies:
- only the case where a fire originates (typically under fault or misuse conditions) within the equipment;
- only equipment installed in normal environments. Hazardous environments, for example in presence of combustible materials, is not to be considered;
- only the case of products selected, installed and used according to the manufacturer instructions and installation rules.
In addition, the following cases are not considered:
- faults addressed by IEC TR 61641;
- risks due to smoke emissions;
- double faults, i.e. multiple phenomenon, potentially combined.

  • Technical report
    20 pages
    English language
    sale 15% off

IEC 62683-1:2017 establishes the reference dictionary of the general description of low-voltage switchgear and controlgear classes based on defined properties.
This dictionary is used to facilitate the exchange in electronic format of data describing low-voltage switchgear and controlgear.
This document provides clear and unambiguous definitions of a limited number of properties and classes which are mainly used for presentation, selection and identification of products particularly in electronic catalogues.
Each property has an unambiguously defined meaning and naming, and, where relevant, a defined value list, a defined format and a defined unit.
The intention is not to cover manufacturer-specific features.

  • Standard
    277 pages
    English and French language
    sale 15% off

IEC 60947-2:2016 applies to circuit-breakers, the main contacts of which are intended to be connected to circuits, the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c.; it also contains additional requirements for integrally fused circuit-breakers. This fifth edition cancels and replaces the fourth edition published in 2006, Amendment 1:2009 and Amendment 2:2013. This edition constitutes a technical revision. This edition includes the following significant additions with respect to the previous edition:
- tests for verification of selectivity in Annex A (see A.5.3);
- critical load current tests for d.c. circuit-breakers (see 8.3.9);
- new Annex P for circuit-breakers for use in photovoltaic applications;
- new Annex R for residual-current circuit-breakers with automatic reclosing functions. The contents of the corrigendum of November 2016 have been included in this copy.

  • Standard
    751 pages
    English language
    sale 15% off
  • Standard
    4 pages
    English and French language
    sale 15% off
  • Standard
    497 pages
    English and French language
    sale 15% off
  • Standard
    1293 pages
    English and French language
    sale 15% off

IEC 60947-5-1:2016 applies to control circuit devices and switching elements intended for controlling, signalling, interlocking, etc., of switchgear and controlgear. It applies to control circuit devices having a rated voltage not exceeding 1 000 V a.c. (at a frequency not exceeding 1 000 Hz) or 600 V d.c. This fourth edition cancels and replaces the third edition published in 2003 and its Amendment 1:2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) update of normative references;
b) update and restructuration of subclauses in 7.1;
c) addition of material requirements and test;
d) udpate of EMC requirements;
e) clarification of requirements and update of 8.2;
f) addition of requirements for screwless-type clamping units;
g) udpate of existing Tables 4 and 5;
h) addition of new Tables 6, 7, 8 and 9;
i) addition of a new Figure 10 ;
j) addition of a new Annex N.
This publication is to be read in conjunction with IEC 60947-1:2007.
The contents of the corrigendum of July 2016 and the corrigendum of April 2020 have been included in this copy.

  • Standard
    328 pages
    English language
    sale 15% off
  • Standard
    214 pages
    English and French language