This European Standard specifies the requirements for septic tanks assembled in situ from prefabricated kits and ancillary equipment where applicable, used outside buildings for the partial treatment of domestic wastewater for a population up to 50 PT. Pipe sizes, loads, watertightness, marking and evaluation of conformity are specified. This standard does not apply to septic tanks receiving grey water only.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    25 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements, test methods, the marking and evaluation of conformity for packaged and/or site assembled domestic wastewater treatment plants (including guest houses and businesses) used for populations up to 50 inhabitants. Small wastewater treatment plants according to this European Standard are used for the treatment of raw domestic wastewater. It covers plants with tanks made of concrete, steel, PVC-U, Polyethylene (PE), Polypropylene (PP) and Glass Reinforced Polyester (GRP-UP). The test methods specified in this European Standard establish the performance of the plant, needed to verify its suitability for the end use. This European Standard applies for small wastewater treatment plants for use buried in the ground where no vehicle loads are applied to the product. This European Standard applies to plants where all prefabricated components are factory or site-assembled by one manufacturer and which are tested as a whole.

  • Standard
    64 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    61 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements, test methods, the marking and evaluation of conformity for a packaged and/or site assembled tertiary treatment unit for installation either separately or in a pre-existing unit. It applies for tertiary treatment units that are placed on the market as complete units used for the tertiary treatment of domestic wastewater by biological, physical, chemical, electrical processes and coming from: a) units in accordance with EN 12566-3 or EN 12566-6; b) installations designed and constructed in accordance with CEN/TR 12566-5. Equivalent secondary treated effluent may come from existing systems. Package and/or site assembled tertiary treatment units according to this standard consist of one or more watertight tanks without any direct infiltration into the ground, made of concrete, corrosion resistant or coated steel, un-plasticised poly-vinyl chloride (PVC-U), polyethylene (PE), glass reinforced thermosetting plastics (GRP) based on polyester resin (UP) (GRP-UP), polypropylene (PP) and polydicyclopentadiene (PDCPD).

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    46 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements, test methods, evaluation of conformity and marking for prefabricated secondary treatment units used for the treatment of effluent from septic tanks according to EN 12566-1 or EN 12566-4 in small wastewater treatment systems for up to 50 PT.

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    47 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for prefabricated septic tanks and ancillary equipment used for the partial treatment of domestic wastewater for a population up to 50 PT. Pipe sizes, loads, watertightness, marking and quality control are specified. The following cases are excluded: - septic tanks receiving grey water only; - in situ constructed septic tanks.

  • Standard
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    49 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements, test methods, the marking and evaluation of conformity for packaged and/or site assembled domestic wastewater treatment plants (including guest houses and businesses) used for populations up to 50 inhabitants. Small wastewater treatment plants according to this European Standard are used for the treatment of raw domestic wastewater. It covers plants with tanks made of concrete, steel, PVC-U, Polyethylene (PE), Polypropylene (PP) and Glass Reinforced Polyester (GRP-UP). The test methods specified in this European Standard establish the performance of the plant, needed to verify its suitability for the end use. This European Standard applies for small wastewater treatment plants for use buried in the ground where no vehicle loads are applied to the product. This European Standard applies to plants where all prefabricated components are factory or site-assembled by one manufacturer and which are tested as a whole.

  • Standard
    64 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    61 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements, test methods, evaluation of conformity and marking for prefabricated secondary treatment units used for the treatment of effluent from septic tanks according to EN 12566-1 or EN 12566-4 in small wastewater treatment systems for up to 50 PT.

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    47 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for septic tanks assembled in situ from prefabricated kits and ancillary equipment where applicable, used outside buildings for the partial treatment of domestic wastewater for a population up to 50 PT. Pipe sizes, loads, watertightness, marking and evaluation of conformity are specified. This standard does not apply to septic tanks receiving grey water only.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    25 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements for prefabricated septic tanks and ancillary equipment used for the partial treatment of domestic wastewater for a population up to 50 PT. Pipe sizes, loads, watertightness, marking and quality control are specified. The following cases are excluded: - septic tanks receiving grey water only; - in situ constructed septic tanks.

  • Standard
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    49 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements, test methods, the marking and evaluation of conformity for a packaged and/or site assembled tertiary treatment unit for installation either separately or in a pre-existing unit. It applies for tertiary treatment units that are placed on the market as complete units used for the tertiary treatment of domestic wastewater by biological, physical, chemical, electrical processes and coming from: a) units in accordance with EN 12566-3 or EN 12566-6; b) installations designed and constructed in accordance with CEN/TR 12566-5. Equivalent secondary treated effluent may come from existing systems. Package and/or site assembled tertiary treatment units according to this standard consist of one or more watertight tanks without any direct infiltration into the ground, made of concrete, corrosion resistant or coated steel, un-plasticised poly-vinyl chloride (PVC-U), polyethylene (PE), glass reinforced thermosetting plastics (GRP) based on polyester resin (UP) (GRP-UP), polypropylene (PP) and polydicyclopentadiene (PDCPD).

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard – translation
    46 pages
    Slovenian language
    sale 10% off
    e-Library read for
    1 day

This European Standard applies to lifting plants for limited applications for domestic non-commercial wastewater containing or not containing faecal matter and located below flood level.
NOTE   Limited application means that the number of users is small and the plant is located in the same room as the sanitary appliance(s) served by it ) which are installed in accordance with EN 12056–1 and the layout and calculation are in accordance with EN 12056–4.
This European Standard applies to lifting plants for limited applications designed for wastewater containing faecal matter, where there is another WC available above flood level, and the plants serve no more than a single WC to which it is directly connected (at a distance of max. 0,5 m) and one hand washbasin, one shower and one bidet provided no other sanitary appliance is directly or indirectly connected.
This European Standard also applies to lifting plants for limited applications designed for faecal free wastewater, where a maximum of one hand washbasin or kitchen sink plus one further appliance such as a bathtub or a washing machine or a shower or a dish washer or an urinal are connected. No other sanitary appliance shall be directly or indirectly connected.
This European Standard contains general requirements, basic construction and testing principles, together with information on materials.
Construction and testing requirements for non-return valves used in wastewater lifting plants for limited applications are given in EN 12050 4.
This European Standard does not apply for lifting plants for limited applications for wastewater containing faecal matter where WC flushing is carried out by pressure flush valve.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard applies to lifting plants for wastewater containing faecal matter (referred to as “faecal lifting plants” in this standard) for drainage of locations below flood level in buildings and sites to prevent any backflow of wastewater into the building. These lifting plants may be prefabricated or delivered as prefabricated kits and assembled on site. This standard specifies general requirements, basic construction and testing principles, together with information on materials and assessment and verification of constancy of performance.
Construction and testing requirements for non-return valves used in wastewater lifting plants are given in EN 12050 4.
This European Standard does not apply for pumping installations for drain and sewer systems outside buildings for pumping of municipal wastewater according to EN 752:2008, Annex F.
NOTE    Lifting plants for wastewater containing faecal matter can also be used for wastewater that does not contain faecal matter and for surface water.
This European Standard applies also to lifting plants for wastewater containing faecal matter which are not prefabricated but composed of individual components purchased from different suppliers and put together on site.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard applies to non-return valves used for faecal-free wastewater and wastewater containing faecal matter lifting plants. This Standard specifies general requirements, basic construction and testing principles together with information on materials and the relevant assessment and verification of constancy of performance.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard applies to lifting plants for faecal-free wastewater for drainage of locations below flood level in buildings and sites to prevent any backflow of wastewater into the building. These lifting plants may be prefabricated or delivered as prefabricated kits and assembled on site. This standard specifies general requirements, basic construction and testing principles, together with information on materials and assessment and verification of constancy of performance.
Construction and testing requirements for non-return valves used in wastewater lifting plants are given in EN 12050 4.
This European Standard does not apply for pumping installations for drain and sewer systems outside buildings for pumping of municipal wastewater according to EN 752:2008, Annex F.
This European Standard applies also to lifting plants for faecal-free wastewater which are not prefabricated but composed of individual components purchased from different suppliers and put together on site.

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard applies to lifting plants for limited applications for domestic non-commercial wastewater containing or not containing faecal matter and located below flood level.
NOTE   Limited application means that the number of users is small and the plant is located in the same room as the sanitary appliance(s) served by it ) which are installed in accordance with EN 12056–1 and the layout and calculation are in accordance with EN 12056–4.
This European Standard applies to lifting plants for limited applications designed for wastewater containing faecal matter, where there is another WC available above flood level, and the plants serve no more than a single WC to which it is directly connected (at a distance of max. 0,5 m) and one hand washbasin, one shower and one bidet provided no other sanitary appliance is directly or indirectly connected.
This European Standard also applies to lifting plants for limited applications designed for faecal free wastewater, where a maximum of one hand washbasin or kitchen sink plus one further appliance such as a bathtub or a washing machine or a shower or a dish washer or an urinal are connected. No other sanitary appliance shall be directly or indirectly connected.
This European Standard contains general requirements, basic construction and testing principles, together with information on materials.
Construction and testing requirements for non-return valves used in wastewater lifting plants for limited applications are given in EN 12050 4.
This European Standard does not apply for lifting plants for limited applications for wastewater containing faecal matter where WC flushing is carried out by pressure flush valve.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard applies to lifting plants for wastewater containing faecal matter (referred to as “faecal lifting plants” in this standard) for drainage of locations below flood level in buildings and sites to prevent any backflow of wastewater into the building. These lifting plants may be prefabricated or delivered as prefabricated kits and assembled on site. This standard specifies general requirements, basic construction and testing principles, together with information on materials and assessment and verification of constancy of performance.
Construction and testing requirements for non-return valves used in wastewater lifting plants are given in EN 12050 4.
This European Standard does not apply for pumping installations for drain and sewer systems outside buildings for pumping of municipal wastewater according to EN 752:2008, Annex F.
NOTE    Lifting plants for wastewater containing faecal matter can also be used for wastewater that does not contain faecal matter and for surface water.
This European Standard applies also to lifting plants for wastewater containing faecal matter which are not prefabricated but composed of individual components purchased from different suppliers and put together on site.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard applies to non-return valves used for faecal-free wastewater and wastewater containing faecal matter lifting plants. This Standard specifies general requirements, basic construction and testing principles together with information on materials and the relevant assessment and verification of constancy of performance.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard applies to lifting plants for faecal-free wastewater for drainage of locations below flood level in buildings and sites to prevent any backflow of wastewater into the building. These lifting plants may be prefabricated or delivered as prefabricated kits and assembled on site. This standard specifies general requirements, basic construction and testing principles, together with information on materials and assessment and verification of constancy of performance.
Construction and testing requirements for non-return valves used in wastewater lifting plants are given in EN 12050 4.
This European Standard does not apply for pumping installations for drain and sewer systems outside buildings for pumping of municipal wastewater according to EN 752:2008, Annex F.
This European Standard applies also to lifting plants for faecal-free wastewater which are not prefabricated but composed of individual components purchased from different suppliers and put together on site.

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements for vitrified clay pipes and joints for pipe jacking for buried drain and sewer systems for the conveyance of wastewater (including domestic wastewater, surface water and rainwater) under gravity and periodic hydraulic surcharge or under continuous low head of pressure. Pipe jacking techniques include micro-tunnelling, pipe-eating, pipe bursting and where appropriate lining with discrete pipes.
This standard also specifies requirements for rubber, polyurethane, polypropylene, stainless steel and other materials used for joints for pipe jacking.
NOTE   Corresponding provisions for the evaluation of conformity (ITT and FPC) and sampling and those for the test methods are further specified in EN 295-2 and EN 295-3, respectively.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard applies for components for vitrified clay manholes and inspection chambers for buried drain and sewer systems for the conveyance of wastewater (including domestic wastewater, surface water and rainwater) under gravity and periodic hydraulic surcharge or under continuous low head of pressure.
It specifies different strength classes and heights of sections. It also specifies the requirements for components used for joints, systems of joint dimensions and the materials rubber, polyurethane and polypropylene used for joints.
NOTE 1   The specifiers/purchasers can select the components for vitrified clay manholes and inspection chambers according to their requirements.
This standard does not apply to manhole tops and cover slabs.
NOTE 2   Corresponding provisions for the evaluation of conformity (ITT and FPC) and sampling and those for the test methods are further specified in EN 295-2 and EN 295-3, respectively.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements for perforated pipes and compatible fittings made from vitrified clay with or without sockets for use in land drains and drainage of waste tips. They are also used for percolation into the ground.
This standard specifies different strength classes and areas of perforations.
NOTE 1   The specifiers/purchasers can select perforated pipes and compatible fittings according to their requirements.
NOTE 2   Corresponding provisions for the evaluation of conformity (ITT and FPC) and sampling and those for the test methods are further specified in EN 295-2 and EN 295-3, respectively.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements for vitrified clay pipes, fittings and flexible joints for buried drain and sewer systems for the conveyance of wastewater (including domestic wastewater, surface water and rainwater) under gravity and periodic hydraulic surcharge or under continuous low head of pressure.
This standard also specifies requirements for rubber, polyurethane and polypropylene materials and other components used for jointing clay pipes and fittings.
This standard specifies different strength classes, systems of joint dimensions, lengths and fittings.
NOTE 1   The specifiers/purchasers can select them according to their requirements.
This standard does not apply to special fittings, adaptors and compatible accessories, perforated pipes and fittings, manholes and inspection chambers and pipes and joints for pipe jacking, which are specified in other parts of the standard series EN 295.
NOTE 2   Corresponding provisions for the evaluation of conformity (ITT and FPC) and sampling and those for the test methods are further specified in EN 295-2 and EN 295-3, respectively.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements for adaptors and connectors made from vitrified clay and/or other suitable materials for use with vitrified clay pipes and fittings for buried drain and sewer systems for the conveyance of wastewater (including domestic wastewater, surface water and rainwater) under gravity and periodic hydraulic surcharge or under continuous low head of pressure.
Adaptors and connectors include insertable fittings, sealing rings for cut pipes and heat-shrinkable sleeves.
This standard also applies for metal banded flexible couplings and adaptors and specifies requirements for rubber, polyurethane, stainless steel and other components used for them.
NOTE 1   The specifiers/purchasers can select adaptors, connectors and flexible couplings according to their requirements.
NOTE 2   Corresponding provisions for the evaluation of conformity (ITT and FPC) and sampling and those for the test methods are further specified in EN 295 2 and EN 295 3, respectively.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements for the evaluation of conformity of products manufactured from vitrified clay and other materials (referred to as "products") specified in the following standards:
-   pipes, fittings and joints according to EN 295-1;
-   adapters, connectors and flexible couplings according to EN 295-4;
-   perforated pipes and fittings according to EN 295-5;
-   components of manholes and inspection chambers according to EN 295-6; and
-   pipes and joints for pipe jacking according to EN 295-7.

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements for adaptors and connectors made from vitrified clay and/or other suitable materials for use with vitrified clay pipes and fittings for buried drain and sewer systems for the conveyance of wastewater (including domestic wastewater, surface water and rainwater) under gravity and periodic hydraulic surcharge or under continuous low head of pressure.
Adaptors and connectors include insertable fittings, sealing rings for cut pipes and heat-shrinkable sleeves.
This standard also applies for metal banded flexible couplings and adaptors and specifies requirements for rubber, polyurethane, stainless steel and other components used for them.
NOTE 1   The specifiers/purchasers can select adaptors, connectors and flexible couplings according to their requirements.
NOTE 2   Corresponding provisions for the evaluation of conformity (ITT and FPC) and sampling and those for the test methods are further specified in EN 295 2 and EN 295 3, respectively.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements for vitrified clay pipes, fittings and flexible joints for buried drain and sewer systems for the conveyance of wastewater (including domestic wastewater, surface water and rainwater) under gravity and periodic hydraulic surcharge or under continuous low head of pressure.
This standard also specifies requirements for rubber, polyurethane and polypropylene materials and other components used for jointing clay pipes and fittings.
This standard specifies different strength classes, systems of joint dimensions, lengths and fittings.
NOTE 1   The specifiers/purchasers can select them according to their requirements.
This standard does not apply to special fittings, adaptors and compatible accessories, perforated pipes and fittings, manholes and inspection chambers and pipes and joints for pipe jacking, which are specified in other parts of the standard series EN 295.
NOTE 2   Corresponding provisions for the evaluation of conformity (ITT and FPC) and sampling and those for the test methods are further specified in EN 295-2 and EN 295-3, respectively.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements for vitrified clay pipes and joints for pipe jacking for buried drain and sewer systems for the conveyance of wastewater (including domestic wastewater, surface water and rainwater) under gravity and periodic hydraulic surcharge or under continuous low head of pressure. Pipe jacking techniques include micro-tunnelling, pipe-eating, pipe bursting and where appropriate lining with discrete pipes.
This standard also specifies requirements for rubber, polyurethane, polypropylene, stainless steel and other materials used for joints for pipe jacking.
NOTE   Corresponding provisions for the evaluation of conformity (ITT and FPC) and sampling and those for the test methods are further specified in EN 295-2 and EN 295-3, respectively.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard applies for components for vitrified clay manholes and inspection chambers for buried drain and sewer systems for the conveyance of wastewater (including domestic wastewater, surface water and rainwater) under gravity and periodic hydraulic surcharge or under continuous low head of pressure.
It specifies different strength classes and heights of sections. It also specifies the requirements for components used for joints, systems of joint dimensions and the materials rubber, polyurethane and polypropylene used for joints.
NOTE 1   The specifiers/purchasers can select the components for vitrified clay manholes and inspection chambers according to their requirements.
This standard does not apply to manhole tops and cover slabs.
NOTE 2   Corresponding provisions for the evaluation of conformity (ITT and FPC) and sampling and those for the test methods are further specified in EN 295-2 and EN 295-3, respectively.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements for the evaluation of conformity of products manufactured from vitrified clay and other materials (referred to as "products") specified in the following standards:
-   pipes, fittings and joints according to EN 295-1;
-   adapters, connectors and flexible couplings according to EN 295-4;
-   perforated pipes and fittings according to EN 295-5;
-   components of manholes and inspection chambers according to EN 295-6; and
-   pipes and joints for pipe jacking according to EN 295-7.

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements for perforated pipes and compatible fittings made from vitrified clay with or without sockets for use in land drains and drainage of waste tips. They are also used for percolation into the ground.
This standard specifies different strength classes and areas of perforations.
NOTE 1   The specifiers/purchasers can select perforated pipes and compatible fittings according to their requirements.
NOTE 2   Corresponding provisions for the evaluation of conformity (ITT and FPC) and sampling and those for the test methods are further specified in EN 295-2 and EN 295-3, respectively.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements for testing of products manufactured from vitrified clay and other materials specified in the following standards:
   pipes, fittings and joints according to EN 295-1;
   adaptors, connectors and flexible couplings according to EN 295-4;
   perforated pipes and fittings according to EN 295-5;
   components of manholes and inspection chambers according to EN 295 6;
   pipes and joints for pipe jacking according to EN 295-7.

  • Standard
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements for testing of products manufactured from vitrified clay and other materials specified in the following standards:
   pipes, fittings and joints according to EN 295-1;
   adaptors, connectors and flexible couplings according to EN 295-4;
   perforated pipes and fittings according to EN 295-5;
   components of manholes and inspection chambers according to EN 295 6;
   pipes and joints for pipe jacking according to EN 295-7.

  • Standard
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day

TC Correction of Figure I.1 (this third Corrigendum to EN 1916:2002 contains the text of AC1, AC2 and AC3)

  • Corrigendum
    24 pages
    English, French and German language
    sale 10% off
    e-Library read for
    1 day

TC Correction of Figure H.1 (this third Corrigendum to EN 1916:2002 contains the text of AC1, AC2 and AC3)

  • Corrigendum
    30 pages
    English, French and German language
    sale 10% off
    e-Library read for
    1 day

TC Correction of Figure I.1 (this third Corrigendum to EN 1916:2002 contains the text of AC1, AC2 and AC3)

  • Corrigendum
    24 pages
    English, French and German language
    sale 10% off
    e-Library read for
    1 day

TC Correction of Figure H.1 (this third Corrigendum to EN 1916:2002 contains the text of AC1, AC2 and AC3)

  • Corrigendum
    30 pages
    English, French and German language
    sale 10% off
    e-Library read for
    1 day

This standard deals with installations for the separation of light liquids (e.g. oil and petrol), i.e. those with a density up to 0.95 g/cm3 from waste water by means of gravity and/or coalescence. The standard is not primarily intended to apply to installations that are required to treat large quantities of trade effluent (e.g., oil refinery effluent). The standard may, however, still be appropriate for this purpose depending on local requirements.

  • Amendment
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

2020-01-20: Originator of XML version: NEN (on behalf of NEN, ASI, DS, SFS, SIS, SN)

  • Amendment
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    3 pages
    German language
    sale 10% off
    e-Library read for
    1 day

2020-01-20: Originator of XML version: NEN (on behalf of NEN, ASI, DS, SFS, SIS, SN)

  • Amendment
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    3 pages
    German language
    sale 10% off
    e-Library read for
    1 day

This standard deals with installations for the separation of light liquids (e.g. oil and petrol), i.e. those with a density up to 0.95 g/cm3 from waste water by means of gravity and/or coalescence. The standard is not primarily intended to apply to installations that are required to treat large quantities of trade effluent (e.g., oil refinery effluent). The standard may, however, still be appropriate for this purpose depending on local requirements.

  • Amendment
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies definitions, nominal sizes, principles of design, performance requirements, marking, testing and quality control for grease separators.
This standard applies to separators for the separation of greases and oils of vegetable and animal origin from wastewater by means of gravity and without any external energy.
This standard does not cover grease separators intended to treat domestic wastewater from kitchen areas of single family dwellings, where the separator has a nominal size less than 1.
The standard is not applicable for the separation of light liquids, e.g. petrol, fuel and heating oil, and does not cover the treatment of wastewater exclusively containing stable emulsions of greases and oils.
The standard does not cover the use of biological means (bacteria and enzymes).

  • Standard
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies definitions, nominal sizes, principles of design, performance requirements, marking, testing and quality control for grease separators.
This standard applies to separators for the separation of greases and oils of vegetable and animal origin from wastewater by means of gravity and without any external energy.
This standard does not cover grease separators intended to treat domestic wastewater from kitchen areas of single family dwellings, where the separator has a nominal size less than 1.
The standard is not applicable for the separation of light liquids, e.g. petrol, fuel and heating oil, and does not cover the treatment of wastewater exclusively containing stable emulsions of greases and oils.
The standard does not cover the use of biological means (bacteria and enzymes).

  • Standard
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard applies to permanently fixed ladders in manholes. It specifies the performance criteria for the mechanical stability and resistance providing protection against falling.
The ladders specified in this European Standard are suitable for use in sewage, rainwater, surface water and, subject to the requirements of national regulations, potable water environments.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard applies to permanently fixed ladders in manholes. It specifies the performance criteria for the mechanical stability and resistance providing protection against falling.
The ladders specified in this European Standard are suitable for use in sewage, rainwater, surface water and, subject to the requirements of national regulations, potable water environments.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard sets out the various relevant test methods for requirements in Part 1.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of this European Standard specifies test methods for anti-flooding devices for buildings according to prEN XXXXX-1.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies general requirements and testing methods for steps manufactured from cast iron, steel or aluminium, for use in manholes and other underground man entry chambers as a means of access.
This standard specifies performance criteria for mechanical stability and resistance providing protection against falling. Corresponding test methods and evaluation of conformity are included.
The steps specified in this European Standard are suitable for use in sewage, surface water  and, subject to the requirements of national regulations, potable water environments.
Where steps are to be used in particular corrosive environments, e.g. industrial effluents, additional protection may be required.
This standard does not apply for steps moulded in prefabricated manholes of the same material.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies requirements for prefabricated linear drainage channels for the collection and conveyance of surface water when installed within areas subject to pedestrian and/or vehicular traffic. It applies to grid units, slot units and kerb units up to a clear opening of 1000 mm.

  • Standard
    58 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    55 pages
    German language
    sale 10% off
    e-Library read for
    1 day