SIST ISO 21438-3:2026
(Main)Workplace atmospheres - Determination of inorganic acids by ion chromatography - Part 3: Hydrofluoric acid and particulate fluorides
- Abstract
This document specifies a method for the determination of the time-weighted average mass concentration of soluble particulate fluorides and hydrofluoric acid (HF) in workplace air by collection of the particulate fluorides on a pre-filter and HF on an alkali-impregnated filter and analysis by ion chromatography.
This method is only applicable to determination of particulate fluorides that are soluble using the sample preparation procedure specified.
For aerosol sampling, this method is applicable to the personal sampling of the inhalable fraction of airborne particles, as defined in ISO 7708, and to static (area) sampling.
The method is applicable to the determination of masses of 0,005 mg to at least 1,25 mg of particulate fluorides per sample and 0,015 mg to at least 1,2 mg of HF per sample.
- Status
- Published
- Public Enquiry End Date
- 02-Aug-2026
- Publication Date
- 13-Sep-2026
- Technical Committee
- KAZ - Air quality
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 06-Aug-2026
- Due Date
- 11-Oct-2026
- Completion Date
- 14-Sep-2026
Buy Documents
ISO 21438-3:2026 - Workplace atmospheres — Determination of inorganic acids by ion chromatography — Part 3: Hydrofluoric acid and particulate fluorides Released:30. 01. 2026
ISO 21438-3:2026 - Air des lieux de travail — Détermination des acides inorganiques par chromatographie ionique — Partie 3: Acide fluorhydrique et fluorures particulaires Released:30. 01. 2026
SIST ISO 21438-3:2026 is the Slovenian standard identical to ISO 21438-3:2026, published by SIST. It specifies a workplace-air method for determining soluble particulate fluorides and hydrofluoric acid (HF) by separate collection on a pre-filter and an alkali-impregnated filter, followed by ion chromatography. It is intended for exposure assessment in personal inhalable sampling and in static area sampling.
What does SIST ISO 21438-3:2026 specify?
SIST ISO 21438-3:2026 specifies how to measure the time-weighted average mass concentration of soluble particulate fluorides and HF in workplace air. The method only applies to particulate fluorides that are soluble using the sample preparation procedure in the document.
The scope covers two sampling situations: personal sampling of the inhalable fraction of airborne particles, as defined in ISO 7708, and static sampling. The stated measuring range reaches from very low masses on the sampling substrate to at least 1,25 mg for particulate fluorides and 1,2 mg for HF.
The document is organized into clauses for the scope, references, terms, principle, performance requirement, reagents, apparatus, occupational exposure assessment, sampling, analysis, expression of results, method performance, and test report. It also includes two informative annexes.
| Annex | What it covers |
|---|---|
| Annex A | Temperature and pressure correction, including corrected sample volume and reference-condition concentration calculations |
| Annex B | Filter materials for pre-filters and HF sampling filters |
What are the key requirements of SIST ISO 21438-3:2026?
SIST ISO 21438-3:2026 requires the measuring procedure to conform to the performance requirements for procedures for measuring chemical agents in air given in ISO 20581. In practice, this means the method is not only a sampling and analysis recipe - it has to meet a broader performance framework for workplace measurements.
Sampling hardware and collection
SIST ISO 21438-3:2026 requires an inhalable sampler that can hold a pre-filter and an alkali-impregnated filter separated by a spacer. The sampler and any internal cassette parts that contact the sample must not react with HF. This matters because HF can attack unsuitable materials and distort the result.
The pre-filter for particulate fluorides must have a collection efficiency of at least 99 % for particles with a 0,3 µm diffusion diameter. The HF filter is impregnated with sodium carbonate. In practice, the document is separating two components of exposure so that particulate fluorides and HF are collected and measured independently.
Sampling strategy and field handling
SIST ISO 21438-3:2026 requires the sampler to be used at its design flow rate and according to the manufacturer’s instructions. Sampling can be personal, in the breathing zone, or static, near the worker or at a background location depending on the task. The sampling period must be long enough to support the intended exposure assessment, but short enough to avoid overloading filters.
The document gives a way to estimate the minimum sampling time from the limit of quantification, flow rate, limit-value factor and limit value. That helps the reader decide whether the planned sampling duration will actually produce a usable result. Field blanks are also required: one unused assembled sampler from each batch of 10 prepared, with a minimum of three.
Temperature, pressure and sample validity
SIST ISO 21438-3:2026 requires attention to temperature and pressure when they can affect the flowmeter reading or the reported concentration. The document tells the user to record atmospheric temperature and pressure at the start and end of sampling when correction is needed. It also states that a selective size-fraction sampler sample is invalid if the flow after sampling deviates by more than 5 % from the pre-sampling flow.
That matters in practice because incorrect flow measurement changes the sampled air volume and therefore the reported concentration. Annex A provides the correction approach for those cases.
Laboratory preparation and calibration
SIST ISO 21438-3:2026 requires sample solutions to be filtered through a 0,45 µm PTFE filter before ion chromatography. The collected filters are extracted separately, with water or eluent depending on the method setup, and without heating. For test solution preparation, the document specifies sonication for 15 min and then standing for 1 h at room temperature.
Calibration has to use at least five calibration solutions and a linear regression calibration function. The calibration is acceptable only when the coefficient of determination is greater than 0,999. The document also requires continuing calibration checks after the initial calibration and after every 10 test solutions.
Quality control, detection limits and uncertainty
SIST ISO 21438-3:2026 requires reagent blanks and laboratory blanks, spiked samples and spiked duplicate samples, and certified reference materials (CRMs) for fluoride. These controls show whether contamination, recovery problems or drift are affecting the batch. The document also describes how to estimate instrumental and method limits of detection (LOD) and limits of quantification (LOQ).
For reporting quality, the document recommends estimating measurement uncertainty according to ISO/IEC Guide 98-3 and using a coverage factor of two. Table 2 states the relative expanded uncertainty targets for comparison with limit values and periodic measurements. In practice, this tells laboratories what level of uncertainty control is expected for workplace exposure results.
Expression of results and interferences
SIST ISO 21438-3:2026 gives formulas for calculating the mass concentration of HF and particulate fluorides in air from the measured fluoride concentrations, the sample volume, the blank results and any dilution factor. It also includes a conversion factor from anion to acid concentration for HF. If needed, the concentrations can be corrected to reference conditions using Annex A.
The document warns that formate and acetate interfere with fluoride detection, and that HF can react with co-sampled particulate matter on the pre-filter. In practice, that means the analyst must watch for false positive fluoride signals and select another technique, such as a fluoride ion selective electrode, if these interferences are present.
What terms does SIST ISO 21438-3:2026 define?
- Blank solution - A reagent, laboratory or field blank taken through the same dissolution procedure as a sample.
- Calibration blank solution - A calibration solution prepared without added working standard solution; its fluoride concentration is taken as zero.
- Calibration solution - A solution prepared by diluting the working standard solution for instrument calibration.
- Sample dissolution - The process used to obtain a fluoride-containing solution from the sample, possibly by complete dissolution.
- Sample solution - The solution obtained from a sample by sample dissolution before any further preparation.
- Test solution - A blank solution or sample solution that has been prepared to the state needed for analysis.
- Stock standard solution - A certified fluoride solution, traceable to national standards, used to prepare calibration solutions.
- Working standard solution - A dilution of the stock standard solution that is better suited for preparing calibration solutions.
Who uses SIST ISO 21438-3:2026?
SIST ISO 21438-3:2026 is used by agencies concerned with health and safety at work, industrial hygienists, public health professionals, analytical laboratories, and industrial users of hydrofluoric acid and particulate fluorides. The document is also relevant to workers whose exposure is being assessed.
In practice, these users apply it to workplace air measurements, exposure assessment, checking the effectiveness of control measures, and reporting results for comparison with occupational exposure limits.
What changed in SIST ISO 21438-3:2026 from the previous edition?
SIST ISO 21438-3:2026 is the second edition and cancels and replaces ISO 21438-3:2010. The document states these main changes:
- the normative references in Clause 2 were updated
- terms also defined in ISO 18158 were removed from Clause 3
- the reagents for electronically suppressed ion chromatography were removed from Clause 6
- Clause 8 was reduced by referencing relevant standards
- Figure 1 was added
Which standards are used with SIST ISO 21438-3:2026?
| Standard | What it contributes |
|---|---|
| ISO 3696 | Water quality specification for analytical laboratory use |
| ISO 7708 | Particle size fraction definitions for health-related sampling |
| ISO 8655-1 | General requirements and terminology for piston-operated volumetric apparatus |
| ISO 8655-2 | Requirements for pipettes |
| ISO 8655-6 | Gravimetric reference measurement procedure for volume determination |
| ISO 18158 | Workplace air terminology |
| ISO 20581:2016 | General performance requirements for procedures for measuring chemical agents in air |
| EN 13205 | Performance assessment of instruments for measurement of airborne particles |
The document also refers, for guidance, to ISO 13137, ISO 8756, ISO 22065, ISO/IEC Guide 98-3, EN 689, ASTM D4840, ASTM D8358, ASTM E882 and ASTM E1370.
What does the SIST ISO 21438-3:2026 document contain?
SIST ISO 21438-3:2026 contains the sampling, preparation, chromatography and reporting steps needed to measure HF and soluble particulate fluorides in workplace air. It includes a sampling figure showing the order of the pre-filter, spacer and impregnated filter, and it gives a table for sodium carbonate impregnation of filters.
The analysis section includes procedures for solution preparation, calibration, instrument checks, LOQ and LOD estimation, and quality control. The performance section summarizes sampling efficiency, storage, humidity influence, upper measuring range, bias, precision, uncertainty and interferences.
Annex A provides formulas and a correction table for temperature and pressure effects. Annex B explains which filter materials are suitable or unsuitable for pre-filters and HF sampling filters, which is useful when choosing consumables for routine monitoring or method setup.
Buy Documents
ISO 21438-3:2026 - Workplace atmospheres — Determination of inorganic acids by ion chromatography — Part 3: Hydrofluoric acid and particulate fluorides Released:30. 01. 2026
ISO 21438-3:2026 - Air des lieux de travail — Détermination des acides inorganiques par chromatographie ionique — Partie 3: Acide fluorhydrique et fluorures particulaires Released:30. 01. 2026
Get Certified
Connect with accredited certification bodies for this standard

ECOCERT
Organic and sustainability certification.
CIS Institut d.o.o.
Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

Eurofins Food Testing Global
Global leader in food, environment, and pharmaceutical product testing.
Sponsored listings
Frequently Asked Questions
SIST ISO 21438-3:2026 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Workplace atmospheres - Determination of inorganic acids by ion chromatography - Part 3: Hydrofluoric acid and particulate fluorides". This standard covers: This document specifies a method for the determination of the time-weighted average mass concentration of soluble particulate fluorides and hydrofluoric acid (HF) in workplace air by collection of the particulate fluorides on a pre-filter and HF on an alkali-impregnated filter and analysis by ion chromatography. This method is only applicable to determination of particulate fluorides that are soluble using the sample preparation procedure specified. For aerosol sampling, this method is applicable to the personal sampling of the inhalable fraction of airborne particles, as defined in ISO 7708, and to static (area) sampling. The method is applicable to the determination of masses of 0,005 mg to at least 1,25 mg of particulate fluorides per sample and 0,015 mg to at least 1,2 mg of HF per sample.
This document specifies a method for the determination of the time-weighted average mass concentration of soluble particulate fluorides and hydrofluoric acid (HF) in workplace air by collection of the particulate fluorides on a pre-filter and HF on an alkali-impregnated filter and analysis by ion chromatography. This method is only applicable to determination of particulate fluorides that are soluble using the sample preparation procedure specified. For aerosol sampling, this method is applicable to the personal sampling of the inhalable fraction of airborne particles, as defined in ISO 7708, and to static (area) sampling. The method is applicable to the determination of masses of 0,005 mg to at least 1,25 mg of particulate fluorides per sample and 0,015 mg to at least 1,2 mg of HF per sample.
SIST ISO 21438-3:2026 is classified under the following ICS (International Classification for Standards) categories: 13.040.30 - Workplace atmospheres; 71.040.50 - Physicochemical methods of analysis; 71.060.30 - Acids. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST ISO 21438-3:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 blank solution
- 3.2 calibration blank solution
- 3.3 calibration solution
- 3.4 extraction solution
- 3.5 sample dissolution
- 3.6 sample solution
- 3.7 stock standard solution
- 3.8 test solution
- 3.9 working standard solution
- 4 Principle
- 5 Requirement
- 6 Reagents
- 7 Apparatus
- 7.1 Sampling equipment
- 7.2 Laboratory apparatus
- 8 Occupational exposure assessment
- 9 Sampling
- 9.1 Preliminary considerations
- 9.2 Preparation for sampling
- 9.3 Sampling position
- 9.4 Collection of samples
- 9.5 Transportation
- 10 Analysis
- 10.1 General
- 10.2 Preparation of test and calibration solutions
- 10.3 Instrument analysis
- 10.4 Estimate of limits of detection (LODs) and limits of quantification (LOQs)
- 10.5 Quality control
- 10.6 Measurement uncertainty
- 11 Expression of results
- 12 Method performance
- 12.1 Sampling efficiency and sample storage
- 12.2 Limit of quantification
- 12.3 Upper limits of the measuring range
- 12.4 Bias and precision
- 12.5 Uncertainty of sampling and analysis method
- 12.6 Interferences
- 13 Test report
- Annex A
- Annex B
- Bibliography
Introduction
The health of workers in many industries is at risk through exposure by inhalation of hydrofluoric acid and particulate fluorides. Industrial hygienists and other public health professionals need to determine the effectiveness of measures taken to control workers' exposure, and this is generally achieved by making workplace air measurements. This document provides a method for making valid exposure measurements for hydrofluoric acid and particulate fluorides in use in industry. It is intended for agencies concerned with health and safety at work; industrial hygienists and other public health professionals; analytical laboratories; industrial users of hydrofluoric acid and particulate fluorides, and their workers. The execution of the provisions and the interpretation of the results obtained with the use of this document is entrusted to appropriately qualified and experienced people.
SIST ISO 21438-3:2026 International Standard ISO 21438-3:2026(en) Workplace atmospheres — Determination of inorganic acids by ion chromatography — Part 3:
Hydrofluoric acid and particulate fluorides
1 Scope
This document specifies a method for the determination of the time-weighted average mass concentration of soluble particulate fluorides and hydrofluoric acid (HF) in workplace air by collection of the particulate fluorides on a pre-filter and HF on an alkali-impregnated filter and analysis by ion chromatography. This method is only applicable to determination of particulate fluorides that are soluble using the sample preparation procedure specified.
For aerosol sampling, this method is applicable to the personal sampling of the inhalable fraction of airborne particles, as defined in ISO 7708, and to static (area) sampling. The method is applicable to the determination of masses of 0,005 mg to at least 1,25 mg of particulate fluorides per sample and 0,015 mg to at least 1,2 mg of HF per sample.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 3696, Water for analytical laboratory use — Specification and test methods ISO 7708, Air quality — Particle size fraction definitions for health-related sampling ISO 8655-1, Piston-operated volumetric apparatus — Part 1: Terminology, general requirements and user recommendations ISO 8655-2, Piston-operated volumetric apparatus — Part 2: Pipettes ISO 8655-6, Piston-operated volumetric apparatus — Part 6: Gravimetric reference measurement procedure for the determination of volume ISO 18158, Workplace air — Terminology ISO 20581:2016, Workplace air — General requirements for the performance of procedures for the measurement of chemical agents EN 13205, Workplace atmospheres — Assessment of performance of instruments for measurement of airborne particles
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 18158 and the following apply.
SIST ISO 21438-3:2026 ISO 21438-3:2026(en) ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at https:// www .electropedia .org/
3.1 blank solution
solution prepared by taking a reagent blank, laboratory blank or field blank through the same procedure used for sample dissolution (3.5)
3.2 calibration blank solution
calibration solution (3.3) prepared without the addition of any working standard solution (3.9) Note 1 to entry: The concentration of fluoride in the calibration blank solution is taken to be zero.
3.3 calibration solution
solution prepared by dilution of the working standard solution (3.9), containing an analyte at concentrations that are suitable for use of the analytical instrument calibration blank
3.4 extraction solution
solvent or solution used to solubilise the analyte(s) of interest
3.5 sample dissolution
process of obtaining a solution containing fluoride from a sample, which can involve complete dissolution of the sample
3.6 sample solution
solution prepared from a sample by the process of sample dissolution (3.5) Note 1 to entry: A sample solution can require further operations, for example dilution, in order to produce a test solution (3.8) that is ready for analysis.
3.7 stock standard solution
solution, used for preparation of the calibration solutions (3.3), containing fluoride at a certified concentration that is traceable to national standards
3.8 test solution
blank solution (3.1) or sample solution (3.6) that has been subjected to all operations required to bring it into a state in which it is ready for analysis Note 1 to entry: The blank test solution is the blank solution and the sample test solution is the sample solution if these solutions are not subjected to any further operations before analysis.
3.9 working standard solution
solution, prepared by dilution of the stock standard solution (3.7), that contains fluoride at a concentration that is better suited for preparation of calibration solutions (3.3) than the concentration of fluoride in the stock standard solution
4 Principle
A known volume of air is drawn through a pre-filter and an alkali-impregnated filter mounted in an inhalable sampler (7.1.1) to collect particulate fluorides and HF. Particulate fluorides are collected on the pre-filter and HF is collected on the alkali-impregnated filter.
SIST ISO 21438-3:2026 ISO 21438-3:2026(en) The pre-filter and alkali-impregnated filter are extracted separately with water or eluent (see 10.2.1), without heating, to solubilize the fluorides.
Aliquots of the sample solution are subjected to ion chromatography in order to separate the extracted fluoride from other anions. Following this separation, fluoride is measured using a conductivity detector. Analytical results are obtained by plotting the measured conductivity as a function of concentration. They can be used for assessment of occupational exposure to fluorides and HF in air.
5 Requirement
The measuring procedure shall conform with the performance requirements for procedures for measuring chemical agents in air given in ISO 20581.
6 Reagents
Use only reagents of recognized analytical grade and only water as specified in ISO 20581. It is advisable to check the blank values of all chemicals before use.
NOTE The presence of acetate or formate in reagents can cause a significant interference on fluoride detection. 6.1 Water, from a purification system that delivers ultrapure water of grade 1 in accordance with the requirements of ISO 3696.
NOTE State of art water purification systems deliver water of grade 1 with higher quality than specified in ISO 3696 (e.g. resistivity greater than 18 MΩ·cm).
6.2 Sodium carbonate (Na CO ), anhydrous, with a mass fraction greater than 99,9 %. 2 3 6.3 Sodium carbonate impregnation solution, for impregnation of 37 mm diameter filters. The solution concentration (in g/l) and impregnation volume (in μl) are given in Table 1 for cellulose ester filters and for quartz fibre filters.
Table 1 — Solution concentration and impregnation volume Filter type Solution concentration Impregnation volume Reference g/l μl Cellulose ester 79,5 240 [13] Quartz fibre 50 500 [14] Adjustments can be made to the solution concentration as needed; however, corresponding adjustments to the impregnation volume are required to ensure that the amount of Na CO impregnated on the filter 2 3 remains the same.
6.4 Fluoride standard solutions.
6.4.1 Fluoride stock standard solution.
Use a commercial standard solution with a certificate of its concentration, for example 1 000 mg/l, traceable to national standards. Observe the manufacturer's expiry date or recommended shelf-life. If necessary, dilute the standard solution (e.g. from 1 000 mg/l to 100 mg/l) to prepare the stock solution. 6.4.2 Fluoride calibration solutions.
Pipette appropriate volumes of the stock solution to create the calibration. The calibration range shall be in accordance with the measuring range described in ISO 20581:2016, 5.4.4. A multi-point (the number of
SIST ISO 21438-3:2026 ISO 21438-3:2026(en) points to be consistent with the quality system of the laboratory) calibration shall be constructed within the linear range of the analytical method.
6.4.3 Fluoride check standard.
Use a certified reference material (CRM) as described in 10.5.3 with a certificate of its concentration, for example 100 mg/l for fluoride, traceable to national standards. Observe the manufacturer's expiry date or recommended shelf life.
6.4.4 Fluoride check standard working solution.
The check standard working solution should be in the middle of the calibration range. Pipette a proper volume of fluoride check standard (6.4.3) to create a check standard with the water (6.1). Prepare this solution fresh for every calibration. If necessary, create a check standard working solution for fluoride separately.
7 Apparatus
7.1 Sampling equipment
7.1.1 Samplers, designed to collect the inhalable fraction of airborne particles, suitable for mounting a pre-filter and an alkali-impregnated filter separated by a spacer, manufactured from a material that does not react with HF. The performance of samplers shall be in accordance with EN 13205 where specific sizeselective fractions are stipulated. The operating instructions supplied by the manufacturer should be consulted to find out whether particulate matter deposited on the internal surfaces of the sampler forms part of the sample. If samplers have an internal filter cassette, this shall also be manufactured from a material that does not react with HF.
NOTE 1 Materials which do not react with acids, from which samplers and internal filter cassettes can be manufactured, include polytetrafluoroethylene (PTFE) and other fluorinated polymers, polyvinyl chloride (PVC), polyethylene, polypropylene and polycarbonate.
NOTE 2 Some inhalable samplers are designed to collect the inhalable fraction of airborne particles on the filter and any particulate matter deposited on the internal surfaces of the sampler is not of interest. Other inhalable samplers are designed such that airborne particles which pass through the entry orifice(s) match the inhalable convention, in which case particulate matter deposited on the internal surfaces of the sampler does form part of the sample. However, all [20] samplers collect particles on the inner surface of the sampler . [12] NOTE 3 CEN/TR 15230 gives examples of inhalable samplers with the potential to meet the requirements of EN 13205, including published reports on their performance.
NOTE 4 In general, personal samplers for collection of the inhalable fraction of airborne particles do not exhibit the same size-selective characteristics if used for static sampling. 7.1.2 Filters, of a diameter suitable for use with the samplers (7.1.1). 7.1.2.1 Pre-filters, for sampling particulate fluorides, with a collection efficiency ≥99 % for particles with a 0,3 µm diffusion diameter, manufactured from a material that does not react with HF. Refer to Clause B.1 for guidance on suitable materials from which pre-filters can be manufactured. 7.1.2.2 Sampling filters, for sampling HF, impregnated with sodium carbonate, for example:
7.1.3 Spacers, of a diameter suitable for use with the samplers (7.1.1) for separating the pre-filters (7.1.2.1) and HF sampling filters (7.1.2.2), manufactured from an inert material that does not react with the
SIST ISO 21438-3:2026 ISO 21438-3:2026(en) acids and on which the acids are not adsorbed, for example polypropylene sleeves, PTFE-coated screens or polystyrene rings.
[3] 7.1.4 Sampling pumps, according to ISO 13137 should be used.
[3] If the sampling pump is used outside the range of conditions specified in ISO 13137 , appropriate action should be taken to ensure that the performance requirements are met. For instance, at sub-zero temperatures it can be necessary to keep the pump warm.
7.1.5 Flowmeter, portable, with an accuracy that is sufficient to enable the volumetric flow rate to be measured to within ± 5 %.
The calibration of the flowmeter shall be checked against a primary standard, i.e. a flowmeter whose accuracy is traceable to national standards. If appropriate (see 9.1.3), record the atmospheric temperature and pressure at which the calibration of the flowmeter was checked. It is advisable that the flowmeter used is capable of measuring the volumetric flow rate to within ±2 % or better.
7.1.6 Ancillary equipment:
- flexible tubing, for example silicone of an outer diameter of 10 mm and an inner diameter of 6 mm for making a leakproof connection from the samplers to the sampling pumps without compressing as a result of the pressure difference between ambient atmosphere and the in-line vacuum at the used flow −1 rate of 1 l min ;
- belts or harnesses, which the sampling pump can conveniently fix for personal sampling;
- tweezers, manufactured from or tipped with PTFE, for handling filters;
- filter transport cassettes, or similar, if required (see 9.5), in which to transport samples to the laboratory;
- thermometer, of range 0 °C to 50 °C, graduated in divisions of at least 1 °C or less, for the measurement of atmospheric temperature; for applications at temperatures below freezing, the range of the thermometer shall extend to the appropriate desired range;
- barometer, suitable for measurement of atmospheric pressure, if required.
7.2 Laboratory apparatus
CAUTION — Fluorides are found ubiquitously in the environment. This can lead to elevated blanks so it is especially important to take great care that all disposable plastic labware is checked for fluoride contamination and that all reusable laboratory apparatus is thoroughly clean before use. 7.2.1 Disposable gloves, impermeable, to avoid the possibility of contamination from the hands and to protect them from contact with toxic and corrosive substances. PVC gloves are suitable. 7.2.2 Plastic labware:
- one-mark volumetric flasks, e.g. example polymethylpentene (PMP);
- screw-cap polyethylene vessels, proper for the extraction of collected sample filters;
- beakers, of appropriate capacity;
- disposable membrane filters, of PTFE, with pore size of 0,45 µm, for use in ion chromatography;
- disposable syringes, of appropriate capacity, appropriate needles;
- autosampler vials, of appropriate capacity.
SIST ISO 21438-3:2026 ISO 21438-3:2026(en) 7.2.3 Piston-operated volumetric instruments, of capacities of 50 µl to 10 ml, conforming with the requirements of ISO 8655-1 and tested in accordance with ISO 8655-6; pipettors conforming with the requirements of ISO 8655-2, as an alternative to one-mark pipettes for the preparation of standard solutions, calibration solutions and dilution of samples.
7.2.4 Ultrasonic bath, preferably with a timer, suitable for use in the ultrasonic extraction method for soluble particulate fluorides and hydrofluoric acid.
7.2.5 Ion chromatograph, having the following listed components inclusive. Components and tubing that come into contact with the sample solution or eluent shall, as far as possible, be comprising inert materials, e.g. polyetheretherketone (PEEK):
- pump, capable of delivering a constant flow within the range 0,1 ml/min to 5 ml/min at a pressure of 15 MPa to 150 MPa;
- eluent generation system, for producing an eluent suitable for use with the selected separator column, as an alternative to use of a manually prepared eluent (e.g. see Reference [15]);
- sample injection system, comprising a low dead-volume, non-metallic valve fitted with a sample loop, for injecting the sample solution into the eluent stream;
- guard and separator column, packed with high capacity pellicular anion exchange resin, suitable for resolving fluorides from other inorganic anions;
- suppressor module (chemically suppressed or electronically suppressed) for ion chromatography, suitable for use with the separator column;
- conductivity detector, flow through, low volume, with a non-metallic flow path.
8 Occupational exposure assessment
[10] [9] Refer to ISO 20581, EN 689 and ASTM E1370 for guidance on how to develop an appropriate assessment strategy and for general guidance on measurement strategy.
9 Sampling
9.1 Preliminary considerations
9.1.1 Selection and use of samplers
Select samplers (7.1.1) in accordance with the requirements of the applicable limit value. Size selective samplers shall collect the appropriate fraction of airborne particles as defined in ISO 7708 and confirmed by testing (e.g. using EN 13205). If possible, the samplers selected should be manufactured from conducting material, since samplers manufactured from non-conducting material have electrostatic properties that can influence representative sampling.
Use the samplers at their design flow rate and in accordance with the instructions provided by the [12] manufacturer. See CEN/TR 15230 for further guidance.
NOTE Excessive flowrate leads to a decrease in the collection efficiency of HF vapour.
9.1.2 Sampling period
Select a sampling period that is appropriate for the measurement task (see Clause 8) but ensure that it is long enough to enable particulate fluorides and HF to be determined with acceptable uncertainty at levels of industrial hygiene significance. When high concentrations of airborne particles are anticipated, select a sampling period that is not so long as to risk overloading the filter with particulate matter. For example, estimate the minimum sampling time, t , in minutes, required to ensure that the amount collected is above min
SIST ISO 21438-3:2026 ISO 21438-3:2026(en) the lower limit of the measuring range of the analytical method when particulate fluorides or HF are present in the test atmosphere at the appropriate multiple of its limit value (i.e. 0,1 times for an 8 h time-weighted average limit value or 0,5 times for a short-term limit value), using Formula (1):
m LOQ t (1) min
qk V LV where t is the minimum sampling time, in minutes; min m is the limit of quantification, given as the mass of the analyte on the sampling substrate, in LOQ micrograms; q is the design flow rate, in litres per minute, of the sampler; V k is the appropriate multiple of the limit value; ρ is the limit value, in milligrams per cubic metre.
LV NOTE k is a variable depending on the source of the limit value. For example, k is 0,1 in France for an 8 h timeweighted average limit value and for a short-term limit value. In Germany, k is 0,1 times for an 8 h time-weighted average limit value but 0,5 times for a short-term limit value. If the minimum sampling time is not short enough for the method to be useful for the intended measurement task, consider the possibility of using a sampler designed to be used at a higher flow rate. When high concentrations of airborne particles are anticipated, select a sampling period that is not so long as to risk overloading the pre-filter with particulate matter. When a high concentration of HF is anticipated, select a sampling period that is not so long as to risk exceeding the maximum sampling capacity of the HF sampling filter. See References [13] and [14].
...
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 blank solution
- 3.2 calibration blank solution
- 3.3 calibration solution
- 3.4 extraction solution
- 3.5 sample dissolution
- 3.6 sample solution
- 3.7 stock standard solution
- 3.8 test solution
- 3.9 working standard solution
- 4 Principle
- 5 Requirement
- 6 Reagents
- 7 Apparatus
- 7.1 Sampling equipment
- 7.2 Laboratory apparatus
- 8 Occupational exposure assessment
- 9 Sampling
- 9.1 Preliminary considerations
- 9.2 Preparation for sampling
- 9.3 Sampling position
- 9.4 Collection of samples
- 9.5 Transportation
- 10 Analysis
- 10.1 General
- 10.2 Preparation of test and calibration solutions
- 10.3 Instrument analysis
- 10.4 Estimate of limits of detection (LODs) and limits of quantification (LOQs)
- 10.5 Quality control
- 10.6 Measurement uncertainty
- 11 Expression of results
- 12 Method performance
- 12.1 Sampling efficiency and sample storage
- 12.2 Limit of quantification
- 12.3 Upper limits of the measuring range
- 12.4 Bias and precision
- 12.5 Uncertainty of sampling and analysis method
- 12.6 Interferences
- 13 Test report
- Annex A
- Annex B
- Bibliography
Introduction
The health of workers in many industries is at risk through exposure by inhalation of hydrofluoric acid and particulate fluorides. Industrial hygienists and other public health professionals need to determine the effectiveness of measures taken to control workers' exposure, and this is generally achieved by making workplace air measurements. This document provides a method for making valid exposure measurements for hydrofluoric acid and particulate fluorides in use in industry. It is intended for agencies concerned with health and safety at work; industrial hygienists and other public health professionals; analytical laboratories; industrial users of hydrofluoric acid and particulate fluorides, and their workers. The execution of the provisions and the interpretation of the results obtained with the use of this document is entrusted to appropriately qualified and experienced people.
International Standard ISO 21438-3:2026(en) Workplace atmospheres — Determination of inorganic acids by ion chromatography — Part 3:
Hydrofluoric acid and particulate fluorides
1 Scope
This document specifies a method for the determination of the time-weighted average mass concentration of soluble particulate fluorides and hydrofluoric acid (HF) in workplace air by collection of the particulate fluorides on a pre-filter and HF on an alkali-impregnated filter and analysis by ion chromatography. This method is only applicable to determination of particulate fluorides that are soluble using the sample preparation procedure specified.
For aerosol sampling, this method is applicable to the personal sampling of the inhalable fraction of airborne particles, as defined in ISO 7708, and to static (area) sampling. The method is applicable to the determination of masses of 0,005 mg to at least 1,25 mg of particulate fluorides per sample and 0,015 mg to at least 1,2 mg of HF per sample.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 3696, Water for analytical laboratory use — Specification and test methods ISO 7708, Air quality — Particle size fraction definitions for health-related sampling ISO 8655-1, Piston-operated volumetric apparatus — Part 1: Terminology, general requirements and user recommendations ISO 8655-2, Piston-operated volumetric apparatus — Part 2: Pipettes ISO 8655-6, Piston-operated volumetric apparatus — Part 6: Gravimetric reference measurement procedure for the determination of volume ISO 18158, Workplace air — Terminology ISO 20581:2016, Workplace air — General requirements for the performance of procedures for the measurement of chemical agents EN 13205, Workplace atmospheres — Assessment of performance of instruments for measurement of airborne particles
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 18158 and the following apply.
ISO 21438-3:2026(en) ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at https:// www .electropedia .org/
3.1 blank solution
solution prepared by taking a reagent blank, laboratory blank or field blank through the same procedure used for sample dissolution (3.5)
3.2 calibration blank solution
calibration solution (3.3) prepared without the addition of any working standard solution (3.9) Note 1 to entry: The concentration of fluoride in the calibration blank solution is taken to be zero.
3.3 calibration solution
solution prepared by dilution of the working standard solution (3.9), containing an analyte at concentrations that are suitable for use of the analytical instrument calibration blank
3.4 extraction solution
solvent or solution used to solubilise the analyte(s) of interest
3.5 sample dissolution
process of obtaining a solution containing fluoride from a sample, which can involve complete dissolution of the sample
3.6 sample solution
solution prepared from a sample by the process of sample dissolution (3.5) Note 1 to entry: A sample solution can require further operations, for example dilution, in order to produce a test solution (3.8) that is ready for analysis.
3.7 stock standard solution
solution, used for preparation of the calibration solutions (3.3), containing fluoride at a certified concentration that is traceable to national standards
3.8 test solution
blank solution (3.1) or sample solution (3.6) that has been subjected to all operations required to bring it into a state in which it is ready for analysis Note 1 to entry: The blank test solution is the blank solution and the sample test solution is the sample solution if these solutions are not subjected to any further operations before analysis.
3.9 working standard solution
solution, prepared by dilution of the stock standard solution (3.7), that contains fluoride at a concentration that is better suited for preparation of calibration solutions (3.3) than the concentration of fluoride in the stock standard solution
4 Principle
A known volume of air is drawn through a pre-filter and an alkali-impregnated filter mounted in an inhalable sampler (7.1.1) to collect particulate fluorides and HF. Particulate fluorides are collected on the pre-filter and HF is collected on the alkali-impregnated filter.
ISO 21438-3:2026(en) The pre-filter and alkali-impregnated filter are extracted separately with water or eluent (see 10.2.1), without heating, to solubilize the fluorides.
Aliquots of the sample solution are subjected to ion chromatography in order to separate the extracted fluoride from other anions. Following this separation, fluoride is measured using a conductivity detector. Analytical results are obtained by plotting the measured conductivity as a function of concentration. They can be used for assessment of occupational exposure to fluorides and HF in air.
5 Requirement
The measuring procedure shall conform with the performance requirements for procedures for measuring chemical agents in air given in ISO 20581.
6 Reagents
Use only reagents of recognized analytical grade and only water as specified in ISO 20581. It is advisable to check the blank values of all chemicals before use.
NOTE The presence of acetate or formate in reagents can cause a significant interference on fluoride detection. 6.1 Water, from a purification system that delivers ultrapure water of grade 1 in accordance with the requirements of ISO 3696.
NOTE State of art water purification systems deliver water of grade 1 with higher quality than specified in ISO 3696 (e.g. resistivity greater than 18 MΩ·cm).
6.2 Sodium carbonate (Na CO ), anhydrous, with a mass fraction greater than 99,9 %. 2 3 6.3 Sodium carbonate impregnation solution, for impregnation of 37 mm diameter filters. The solution concentration (in g/l) and impregnation volume (in μl) are given in Table 1 for cellulose ester filters and for quartz fibre filters.
Table 1 — Solution concentration and impregnation volume Filter type Solution concentration Impregnation volume Reference g/l μl Cellulose ester 79,5 240 [13] Quartz fibre 50 500 [14] Adjustments can be made to the solution concentration as needed; however, corresponding adjustments to the impregnation volume are required to ensure that the amount of Na CO impregnated on the filter 2 3 remains the same.
6.4 Fluoride standard solutions.
6.4.1 Fluoride stock standard solution.
Use a commercial standard solution with a certificate of its concentration, for example 1 000 mg/l, traceable to national standards. Observe the manufacturer's expiry date or recommended shelf-life. If necessary, dilute the standard solution (e.g. from 1 000 mg/l to 100 mg/l) to prepare the stock solution. 6.4.2 Fluoride calibration solutions.
Pipette appropriate volumes of the stock solution to create the calibration. The calibration range shall be in accordance with the measuring range described in ISO 20581:2016, 5.4.4. A multi-point (the number of
ISO 21438-3:2026(en) points to be consistent with the quality system of the laboratory) calibration shall be constructed within the linear range of the analytical method.
6.4.3 Fluoride check standard.
Use a certified reference material (CRM) as described in 10.5.3 with a certificate of its concentration, for example 100 mg/l for fluoride, traceable to national standards. Observe the manufacturer's expiry date or recommended shelf life.
6.4.4 Fluoride check standard working solution.
The check standard working solution should be in the middle of the calibration range. Pipette a proper volume of fluoride check standard (6.4.3) to create a check standard with the water (6.1). Prepare this solution fresh for every calibration. If necessary, create a check standard working solution for fluoride separately.
7 Apparatus
7.1 Sampling equipment
7.1.1 Samplers, designed to collect the inhalable fraction of airborne particles, suitable for mounting a pre-filter and an alkali-impregnated filter separated by a spacer, manufactured from a material that does not react with HF. The performance of samplers shall be in accordance with EN 13205 where specific sizeselective fractions are stipulated. The operating instructions supplied by the manufacturer should be consulted to find out whether particulate matter deposited on the internal surfaces of the sampler forms part of the sample. If samplers have an internal filter cassette, this shall also be manufactured from a material that does not react with HF.
NOTE 1 Materials which do not react with acids, from which samplers and internal filter cassettes can be manufactured, include polytetrafluoroethylene (PTFE) and other fluorinated polymers, polyvinyl chloride (PVC), polyethylene, polypropylene and polycarbonate.
NOTE 2 Some inhalable samplers are designed to collect the inhalable fraction of airborne particles on the filter and any particulate matter deposited on the internal surfaces of the sampler is not of interest. Other inhalable samplers are designed such that airborne particles which pass through the entry orifice(s) match the inhalable convention, in which case particulate matter deposited on the internal surfaces of the sampler does form part of the sample. However, all [20] samplers collect particles on the inner surface of the sampler . [12] NOTE 3 CEN/TR 15230 gives examples of inhalable samplers with the potential to meet the requirements of EN 13205, including published reports on their performance.
NOTE 4 In general, personal samplers for collection of the inhalable fraction of airborne particles do not exhibit the same size-selective characteristics if used for static sampling. 7.1.2 Filters, of a diameter suitable for use with the samplers (7.1.1). 7.1.2.1 Pre-filters, for sampling particulate fluorides, with a collection efficiency ≥99 % for particles with a 0,3 µm diffusion diameter, manufactured from a material that does not react with HF. Refer to Clause B.1 for guidance on suitable materials from which pre-filters can be manufactured. 7.1.2.2 Sampling filters, for sampling HF, impregnated with sodium carbonate, for example:
7.1.3 Spacers, of a diameter suitable for use with the samplers (7.1.1) for separating the pre-filters (7.1.2.1) and HF sampling filters (7.1.2.2), manufactured from an inert material that does not react with the
ISO 21438-3:2026(en) acids and on which the acids are not adsorbed, for example polypropylene sleeves, PTFE-coated screens or polystyrene rings.
[3] 7.1.4 Sampling pumps, according to ISO 13137 should be used.
[3] If the sampling pump is used outside the range of conditions specified in ISO 13137 , appropriate action should be taken to ensure that the performance requirements are met. For instance, at sub-zero temperatures it can be necessary to keep the pump warm.
7.1.5 Flowmeter, portable, with an accuracy that is sufficient to enable the volumetric flow rate to be measured to within ± 5 %.
The calibration of the flowmeter shall be checked against a primary standard, i.e. a flowmeter whose accuracy is traceable to national standards. If appropriate (see 9.1.3), record the atmospheric temperature and pressure at which the calibration of the flowmeter was checked. It is advisable that the flowmeter used is capable of measuring the volumetric flow rate to within ±2 % or better.
7.1.6 Ancillary equipment:
- flexible tubing, for example silicone of an outer diameter of 10 mm and an inner diameter of 6 mm for making a leakproof connection from the samplers to the sampling pumps without compressing as a result of the pressure difference between ambient atmosphere and the in-line vacuum at the used flow −1 rate of 1 l min ;
- belts or harnesses, which the sampling pump can conveniently fix for personal sampling;
- tweezers, manufactured from or tipped with PTFE, for handling filters;
- filter transport cassettes, or similar, if required (see 9.5), in which to transport samples to the laboratory;
- thermometer, of range 0 °C to 50 °C, graduated in divisions of at least 1 °C or less, for the measurement of atmospheric temperature; for applications at temperatures below freezing, the range of the thermometer shall extend to the appropriate desired range;
- barometer, suitable for measurement of atmospheric pressure, if required.
7.2 Laboratory apparatus
CAUTION — Fluorides are found ubiquitously in the environment. This can lead to elevated blanks so it is especially important to take great care that all disposable plastic labware is checked for fluoride contamination and that all reusable laboratory apparatus is thoroughly clean before use. 7.2.1 Disposable gloves, impermeable, to avoid the possibility of contamination from the hands and to protect them from contact with toxic and corrosive substances. PVC gloves are suitable. 7.2.2 Plastic labware:
- one-mark volumetric flasks, e.g. example polymethylpentene (PMP);
- screw-cap polyethylene vessels, proper for the extraction of collected sample filters;
- beakers, of appropriate capacity;
- disposable membrane filters, of PTFE, with pore size of 0,45 µm, for use in ion chromatography;
- disposable syringes, of appropriate capacity, appropriate needles;
- autosampler vials, of appropriate capacity.
ISO 21438-3:2026(en) 7.2.3 Piston-operated volumetric instruments, of capacities of 50 µl to 10 ml, conforming with the requirements of ISO 8655-1 and tested in accordance with ISO 8655-6; pipettors conforming with the requirements of ISO 8655-2, as an alternative to one-mark pipettes for the preparation of standard solutions, calibration solutions and dilution of samples.
7.2.4 Ultrasonic bath, preferably with a timer, suitable for use in the ultrasonic extraction method for soluble particulate fluorides and hydrofluoric acid.
7.2.5 Ion chromatograph, having the following listed components inclusive. Components and tubing that come into contact with the sample solution or eluent shall, as far as possible, be comprising inert materials, e.g. polyetheretherketone (PEEK):
- pump, capable of delivering a constant flow within the range 0,1 ml/min to 5 ml/min at a pressure of 15 MPa to 150 MPa;
- eluent generation system, for producing an eluent suitable for use with the selected separator column, as an alternative to use of a manually prepared eluent (e.g. see Reference [15]);
- sample injection system, comprising a low dead-volume, non-metallic valve fitted with a sample loop, for injecting the sample solution into the eluent stream;
- guard and separator column, packed with high capacity pellicular anion exchange resin, suitable for resolving fluorides from other inorganic anions;
- suppressor module (chemically suppressed or electronically suppressed) for ion chromatography, suitable for use with the separator column;
- conductivity detector, flow through, low volume, with a non-metallic flow path.
8 Occupational exposure assessment
[10] [9] Refer to ISO 20581, EN 689 and ASTM E1370 for guidance on how to develop an appropriate assessment strategy and for general guidance on measurement strategy.
9 Sampling
9.1 Preliminary considerations
9.1.1 Selection and use of samplers
Select samplers (7.1.1) in accordance with the requirements of the applicable limit value. Size selective samplers shall collect the appropriate fraction of airborne particles as defined in ISO 7708 and confirmed by testing (e.g. using EN 13205). If possible, the samplers selected should be manufactured from conducting material, since samplers manufactured from non-conducting material have electrostatic properties that can influence representative sampling.
Use the samplers at their design flow rate and in accordance with the instructions provided by the [12] manufacturer. See CEN/TR 15230 for further guidance.
NOTE Excessive flowrate leads to a decrease in the collection efficiency of HF vapour.
9.1.2 Sampling period
Select a sampling period that is appropriate for the measurement task (see Clause 8) but ensure that it is long enough to enable particulate fluorides and HF to be determined with acceptable uncertainty at levels of industrial hygiene significance. When high concentrations of airborne particles are anticipated, select a sampling period that is not so long as to risk overloading the filter with particulate matter. For example, estimate the minimum sampling time, t , in minutes, required to ensure that the amount collected is above min
ISO 21438-3:2026(en) the lower limit of the measuring range of the analytical method when particulate fluorides or HF are present in the test atmosphere at the appropriate multiple of its limit value (i.e. 0,1 times for an 8 h time-weighted average limit value or 0,5 times for a short-term limit value), using Formula (1):
m LOQ t (1) min
qk V LV where t is the minimum sampling time, in minutes; min m is the limit of quantification, given as the mass of the analyte on the sampling substrate, in LOQ micrograms; q is the design flow rate, in litres per minute, of the sampler; V k is the appropriate multiple of the limit value; ρ is the limit value, in milligrams per cubic metre.
LV NOTE k is a variable depending on the source of the limit value. For example, k is 0,1 in France for an 8 h timeweighted average limit value and for a short-term limit value. In Germany, k is 0,1 times for an 8 h time-weighted average limit value but 0,5 times for a short-term limit value. If the minimum sampling time is not short enough for the method to be useful for the intended measurement task, consider the possibility of using a sampler designed to be used at a higher flow rate. When high concentrations of airborne particles are anticipated, select a sampling period that is not so long as to risk overloading the pre-filter with particulate matter. When a high concentration of HF is anticipated, select a sampling period that is not so long as to risk exceeding the maximum sampling capacity of the HF sampling filter. See References [13] and [14].
...
Contents
- Introduction
- 1 Domaine d’application
- 2 Références normatives
- 3 Termes et définitions
- 3.1 solution de blanc
- 3.2 solution de blanc d’étalonnage
- 3.3 solution d’étalonnage
- 3.4 solution d’extraction
- 3.5 mise en solution de l’échantillon
- 3.6 solution d’échantillon
- 3.7 solution étalon mère
- 3.8 solution d’essai
- 3.9 solution étalon de travail
- 4 Principe
- 5 Exigence
- 6 Réactifs
- 6.3 Solution de carbonate de sodium d’imprégnation, pour l’imprégnation de filtres de 37 mm de
- 7 Appareillage
- 7.1 Matériel de prélèvement
- 7.2 Matériel de laboratoire
- 8 Évaluation de l’exposition professionnelle
- 9 Prélèvement
- 9.1 Considérations préliminaires
- 9.2 Préparation du prélèvement
- 9.3 Point de prélèvement
- 9.4 Prélèvement des échantillons
- 9.5 Transport
- 10 Analyse
- 10.1 Généralités
- 10.2 Préparation des solutions d’essai et d’étalonnage
- 10.3 Analyse instrumentale
- 10.4 Estimation des limites de détection (LD) et des limites de quantification (LQ)
- 10.5 Contrôle de la qualité
- 10.6 Incertitude de mesure
- 11 Expression des résultats
- 12 Performances de la méthode
- 12.1 Efficacité de prélèvement et conservation des échantillons
- 12.2 Limite de quantification
- 12.3 Limites supérieures de la gamme de mesure
- 12.4 Biais et fidélité
- 12.5 Incertitude de la méthode de prélèvement et d’analyse
- 12.6 Interférences
- 13 Rapport d’essai
- Annexe A
- Annexe B
- Bibliographie
Introduction
Dans de nombreuses industries, la santé des travailleurs est menacée en raison de l’exposition par inhalation à l’acide fluorhydrique et aux fluorures particulaires. Les hygiénistes industriels et autres professionnels de santé publique ont besoin de déterminer l’efficacité des mesures prises pour contrôler l’exposition des travailleurs, ce qui se traduit en général par la réalisation de mesurages de l’air des lieux de travail. Le présent document fournit une méthode permettant d’effectuer des mesurages d’exposition valides pour l’acide fluorhydrique et les fluorures particulaires utilisés dans l’industrie. Il est destiné aux agences concernées par l’hygiène et la sécurité au travail; aux hygiénistes industriels et aux autres professionnels de la santé publique; aux laboratoires d’analyse; aux industriels utilisateurs d’acide fluorhydrique et de fluorures particulaires et à leurs employés.
La mise en œuvre de ces dispositions et l’interprétation des résultats obtenus grâce à l’utilisation du présent document est confiées à des personnes dotées d’une qualification et d’une expérience appropriées.
Norme internationale ISO 21438-3:2026(fr) Air des lieux de travail — Détermination des acides inorganiques par chromatographie ionique — Partie 3:
Acide fluorhydrique et fluorures particulaires
1 Domaine d’application
Le présent document spécifie une méthode de détermination de la concentration massique moyenne pondérée dans le temps en fluorures particulaires solubles et en acide fluorhydrique (HF) dans l’air des lieux de travail, par prélèvement des fluorures particulaires sur un préfiltre et de l’HF sur un filtre imprégné d’alcali suivi d’une analyse par chromatographie ionique.
Cette méthode est applicable uniquement à la détermination des fluorures particulaires qui sont solubles en utilisant le mode opératoire spécifié pour la préparation des échantillons. En cas de prélèvement d’aérosol, cette méthode est applicable au prélèvement sur opérateur de la fraction inhalable des particules en suspension dans l’air, comme défini dans l’ISO 7708, ainsi qu’au prélèvement à point fixe.
La méthode est applicable à la détermination de masses comprises entre 0,005 mg et au moins 1,25 mg de fluorures particulaires par échantillon et entre 0,015 mg et au moins 1,2 mg d’HF par échantillon.
2 Références normatives
Les documents suivants sont cités dans le texte de sorte qu’ils constituent, pour tout ou partie de leur contenu, des exigences du présent document. Pour les références datées, seule l’édition citée s’applique. Pour les références non datées, la dernière édition du document de référence s’applique (y compris les éventuels amendements).
ISO 3696, Eau pour laboratoire à usage analytique — Spécification et méthodes d'essai ISO 7708, Qualité de l'air — Définitions des fractions de taille des particules pour l'échantillonnage lié aux problèmes de santé ISO 8655-1, Appareils volumétriques à piston — Partie 1: Définitions, exigences générales et recommandations pour l'utilisateur ISO 8655-2, Appareils volumétriques à piston — Partie 2: Pipettes ISO 8655-6, Appareils volumétriques à piston — Partie 6: Mode opératoire de mesure gravimétrique de référence pour la détermination de volumes ISO 18158, Qualité de l'air — Terminologie ISO 20581:2016, Air des lieux de travail — Exigences générales concernant les performances des procédures de mesure des agents chimiques EN 13205, Atmosphères des lieux de travail — Évaluation des performances des instruments de mesurage des concentrations d’aérosols
ISO 21438-3:2026(fr)
3 Termes et définitions
Pour les besoins du présent document, les termes et les définitions de l’ISO 18158 ainsi que les suivants s’appliquent.
L’ISO et l’IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en normalisation, consultables aux adresses suivantes:
- ISO Online browsing platform: disponible à l’adresse https:// www .iso .org/ obp
- IEC Electropedia: disponible à l’adresse https:// www .electropedia .org/
3.1 solution de blanc
solution préparée à partir d’un blanc de réactifs, d’un blanc de laboratoire ou d’un blanc de terrain en utilisant le même mode opératoire que pour la mise en solution de l’échantillon (3.5)
3.2 solution de blanc d’étalonnage
solution d’étalonnage (3.3) préparée sans ajout d’une solution étalon de travail (3.9) Note 1 à l'article: La concentration d’ions fluorure dans la solution de blanc d’étalonnage est considérée comme nulle.
3.3 solution d’étalonnage
solution obtenue par dilution de la solution étalon de travail (3.9), contenant un analyte aux concentrations appropriées au blanc d’étalonnage de l’instrument d’analyse
3.4 solution d’extraction
solvant ou solution utilisés pour solubiliser l’analyte ou les analytes étudiés
3.5 mise en solution de l’échantillon
processus permettant d’obtenir une solution contenant des ions fluorure à partir d’un échantillon, qui peut impliquer la mise en solution complète de l’échantillon
3.6 solution d’échantillon
solution préparée, à partir d’un échantillon, au moyen du processus de mise en solution d’échantillon (3.5) Note 1 à l'article: Une solution d’échantillon peut nécessiter plusieurs opérations, par exemple, une dilution, afin de produire une solution d’essai (3.8) prête pour l’analyse.
3.7 solution étalon mère
solution, utilisée dans la préparation des solutions d’étalonnage (3.3), contenant des ions fluorure à une concentration certifiée dont la traçabilité aux étalons nationaux est établie
3.8 solution d’essai
solution de blanc (3.1) ou solution d’échantillon (3.6) qui a été soumise à toutes les opérations nécessaires pour l’amener à un état dans lequel elle est prête pour l’analyse Note 1 à l'article: Si ces solutions ne sont pas soumises à d’autres traitements avant analyse, la solution d’essai à blanc est la solution de blanc, et la solution d’échantillon est la solution d’essai.
3.9 solution étalon de travail
solution préparée par dilution de la solution étalon mère (3.7), contenant des ions fluorure à une concentration mieux adaptée à la préparation des solutions d’étalonnage (3.3) que la concentration en fluorure de la solution étalon mère
ISO 21438-3:2026(fr)
4 Principe
Un volume connu d’air est prélevé à travers un préfiltre et un filtre imprégné d’alcali, installés dans un dispositif de prélèvement de la fraction inhalable (7.1.1), pour recueillir les fluorures particulaires et l’HF. Les fluorures particulaires sont collectés sur le préfiltre et l’HF est piégé sur le filtre imprégné d’alcali. Le préfiltre et le filtre imprégné d’alcali sont extraits séparément à l’eau ou à l’éluant (voir 10.2.1), sans chauffage, pour solubiliser les fluorures.
Des aliquotes de la solution d’échantillon sont traitées par chromatographie ionique pour séparer les ions fluorure extraits des autres anions. À la suite de cette séparation, le fluorure est mesuré à l’aide d’un détecteur conductimétrique.
Les résultats d’analyse sont obtenus en reportant la conductivité mesurée en fonction de la concentration. Ils peuvent être utilisés pour évaluer l’exposition professionnelle aux fluorures et à l’HF dans l’air.
5 Exigence
La procédure de mesure doit satisfaire aux exigences de performance relatives aux méthodes de mesurage des agents chimiques dans l’air des lieux de travail, telles que définies dans l’ISO 20581.
6 Réactifs
Utiliser uniquement des réactifs de qualité analytique reconnue et de l’eau telle que spécifiée dans l’ISO 20581. Il est recommandé de vérifier les valeurs de blanc de tous les produits chimiques avant utilisation. NOTE La présence d’acétate ou de formiate dans les réactifs peut interférer de manière significative avec la détection des fluorures.
6.1 Eau, d’un système de purification délivrant de l’eau ultrapure de qualité 1, conformément aux exigences de l’ISO 3696.
NOTE Les systèmes de purification actuels du marché fournissent de l’eau de qualité 1 affichant un niveau de qualité supérieur à celui spécifié dans l’ISO 3696 (par exemple une résistivité supérieure à 18 MΩ·cm). 6.2 Carbonate de sodium (Na CO ), anhydre, d’une fraction massique supérieure à 99,9 %. 2 3
6.3 Solution de carbonate de sodium d’imprégnation, pour l’imprégnation de filtres de 37 mm de
diamètre.
La concentration de la solution (en g/l) et le volume d’imprégnation (en μl) sont indiqués dans le Tableau 1 pour les filtres en ester de cellulose et pour les filtres en fibres de quartz. Tableau 1 — Concentration de la solution et volume d’imprégnation Type de filtre Concentration de la solution Volume d’imprégnation Référence g/l μl Ester de cellulose 79,5 240 [13] Fibre de quartz 50 500 [14] Il est possible de modifier la concentration de la solution si besoin; cependant, il est nécessaire d’adapter le volume d’imprégnation en conséquence de sorte à avoir la même quantité de Na CO imprégné sur le filtre. 2 3
ISO 21438-3:2026(fr) 6.4 Solutions étalons de fluorure.
6.4.1 Solution étalon mère de fluorure.
Utiliser une solution étalon du commerce présentant une concentration certifiée (1 000 mg/l par exemple) dont la traçabilité aux étalons nationaux est établie. Respecter la date d’expiration fixée par le fabricant ou la durée de conservation recommandée. Si nécessaire, diluer la solution étalon (par exemple de 1 000 mg/l à 100 mg/l) afin de préparer la solution mère.
6.4.2 Solutions d’étalonnage de fluorure.
Pipeter des volumes appropriés de la solution mère pour obtenir la droite d’étalonnage. Le domaine d’étalonnage doit être conforme à la gamme de mesure décrite dans l’ISO 20581:2016, 5.4.4. Un étalonnage à plusieurs points (nombre de points à déterminer selon le système qualité du laboratoire) doit être mis en œuvre au sein du domaine de linéarité de la méthode d’analyse. 6.4.3 Étalon de référence de fluorure.
Utiliser un matériau de référence certifié (MRC) tel que défini en 10.5.3, de concentration certifiée (par exemple 100 mg/l de fluorure) et dont la traçabilité aux étalons nationaux est établie. Respecter la date d’expiration fixée par le fabricant ou la durée de conservation recommandée. 6.4.4 Solution de travail d’étalon de référence de fluorure.
Il convient que la solution de travail d’étalon de référence se trouve au milieu du domaine d’étalonnage. À l’aide d’une pipette, introduire un volume approprié d’étalon de référence de fluorure (6.4.3) pour créer un étalon de référence avec l’eau (6.1). Préparer cette solution extemporanément à chaque étalonnage. Si nécessaire, préparer une solution de travail d’étalon de référence séparément pour le fluorure.
7 Appareillage
7.1 Matériel de prélèvement
7.1.1 Dispositifs de prélèvement, conçus pour recueillir la fraction inhalable des particules en
suspension dans l’air, permettant le montage d’un préfiltre et d’un filtre imprégné d’alcali séparés par un intercalaire, fabriqués dans un matériau ne réagissant pas avec l’HF. Les performances des dispositifs de prélèvement doivent être conformes à l’EN 13205 lorsque des fractions granulométriques spécifiques sont stipulées.
Il convient de consulter la notice d’utilisation fournie par le fabricant pour déterminer si la matière particulaire déposée sur les surfaces internes du dispositif de prélèvement fait partie de l’échantillon. Si les dispositifs de prélèvement contiennent une cassette porte-filtre interne, celle-ci doit également être fabriquée dans un matériau ne réagissant pas avec l’HF.
NOTE 1 Parmi les matériaux ne réagissant pas avec les acides, dans lesquels les dispositifs de prélèvement et les cassettes porte-filtres internes peuvent être fabriqués, figurent le polytétrafluoroéthylène (PTFE) et autres polymères fluorés, le polychlorure de vinyle (PVC), le polyéthylène, le polypropylène et le polycarbonate. NOTE 2 Certains dispositifs de prélèvement de la fraction inhalable sont conçus pour recueillir la fraction inhalable des particules en suspension dans l’air sur le filtre et la matière particulaire déposée sur les surfaces internes du dispositif de prélèvement ne présente alors aucun intérêt. D’autres dispositifs de prélèvement de la fraction inhalable sont conçus de sorte que les particules en suspension dans l’air qui passent dans les orifices d’entrée correspondent à la convention inhalable, auquel cas la matière particulaire déposée sur les surfaces internes du dispositif de prélèvement fait partie de l’échantillon. Cependant, tous les dispositifs de prélèvement recueillent des particules sur leur surface [20] interne .
[12] NOTE 3 Le CEN/TR 15230 donne des exemples de dispositifs de prélèvement de la fraction inhalable susceptibles de satisfaire aux exigences de l’EN 13205, y compris des rapports publiés sur leurs performances.
ISO 21438-3:2026(fr) NOTE 4 En général, les dispositifs de prélèvement individuels utilisés pour recueillir la fraction inhalable des particules en suspension dans l’air n’ont pas les mêmes caractéristiques de sélection de taille s’ils sont utilisés pour un prélèvement à point fixe.
7.1.2 Filtres, d’un diamètre compatible pour l’utilisation avec les dispositifs de prélèvement (7.1.1). 7.1.2.1 Préfiltres, pour le prélèvement des fluorures particulaires, dont l’efficacité de prélèvement est ≥ 99 % pour les particules ayant un diamètre de diffusion de 0,3 µm, fabriqués dans un matériau ne réagissant pas avec l’HF.
Se reporter à l’Article B.1 pour obtenir des recommandations relatives aux matériaux appropriés pour la fabrication des préfiltres.
7.1.2.2 Filtres de prélèvement, pour le prélèvement de l’HF, imprégnés de carbonate de sodium, par exemple:
7.1.3 Intercalaires, d’un diamètre compatible avec les dispositifs de prélèvement (7.1.1), destinés à séparer les préfiltres (7.1.2.1) et les filtres de prélèvement de l’HF (7.1.2.2), fabriqués dans un matériau inerte ne réagissant pas avec les acides et ne les adsorbant pas, par exemple, manchons en polypropylène ou grilles revêtues de PTFE ou bagues en polystyrène.
[3] 7.1.4 Il convient d’utiliser des pompes de prélèvement conformes à l’ISO 13137 . [3] Si la pompe de prélèvement est utilisée en dehors du domaine des conditions spécifiées dans l’ISO 13137 , il convient de prendre des mesures appropriées pour s’assurer que les exigences de performance sont satisfaites. Par exemple, à des températures inférieures à zéro, il peut se révéler nécessaire de maintenir la pompe au chaud.
7.1.5 Débitmètre, portable, offrant une précision suffisante pour permettre de mesurer le débit
volumétrique à ±5 %.
L’étalonnage du débitmètre doit être vérifié par rapport à un étalon primaire, c’est-à-dire un débitmètre dont la traçabilité de la précision aux étalons nationaux est établie. S’il y a lieu (voir 9.1.3), noter la température et la pression atmosphériques auxquelles l’étalonnage du débitmètre a été vérifié. Il est recommandé que le débitmètre utilisé soit capable de mesurer le débit volumétrique à ±2 % au minimum.
7.1.6 Matériel auxiliaire:
- tuyau souple, par exemple en silicone, d’un diamètre extérieur de 10 mm et d’un diamètre intérieur de 6 mm pour un raccordement étanche entre les dispositifs de prélèvement et les pompes de prélèvement sans phénomène de compression découlant de la différence de pression entre l’atmosphère ambiante et −1 la dépression créée dans le circuit au débit de 1 l min ;
- ceintures ou harnais, auxquels la pompe de prélèvement peut se fixer facilement en vue d’un prélèvement sur opérateur;
- pinces, fabriquées ou recouvertes de PTFE, pour manipuler les filtres;
- cassettes de transport de filtres, ou dispositif analogue, si nécessaire (voir 9.5), permettant de transporter les échantillons jusqu’au laboratoire;
- thermomètre, offrant une plage de lecture de 0 °C à 50 °C, graduée par divisions de 1 °C ou moins, pour le mesurage de la température atmosphérique; pour des applications à des températures négatives, la gamme du thermomètre doit s’étendre à la plage appropriée souhaitée;
- baromètre, adapté au mesurage de la pression atmosphérique si nécessaire.
ISO 21438-3:2026(fr)
7.2 Matériel de laboratoire
ATTENTION — Les fluorures sont omniprésents dans l’environnement, ce qui peut se traduire par des niveaux de blanc élevés. Il est donc particulièrement important de contrôler soigneusement la verrerie de laboratoire en plastique à usage unique afin de déceler toute contamination aux fluorures, et de nettoyer complètement tout le matériel de laboratoire réutilisable avant utilisation. 7.2.1 Gants à usage unique, imperméables, pour éviter toute possibilité de contamination par les mains et pour les protéger de tout contact avec des substances toxiques et corrosives. Des gants en PVC sont adéquats.
7.2.2 Matériel de laboratoire en plastique:
- fioles jaugées à un trait, par exemple en polyméthylpentène (PMP);
- récipients en polyéthylène à bouchon à vis, adaptés pour l’extraction des échantillons collectés sur les filtres;
- béchers, de capacité appropriée;
- membranes filtrantes à usage unique, en PTFE, d’une porosité de 0,45 µm, destinées à la chromatographie ionique;
- seringues jetables, de capacité appropriée, avec aiguilles adaptées;
- flacons de passeur automatique, de capacité appropriée.
7.2.3 Appareils volumétriques à piston, d’une capacité de 50 µl à 10 ml, conformes aux exigences de l’ISO 8655-1 et soumis à essai conformément à l’ISO 8655-6; possibilité d’utiliser des pipettes conformes aux exigences de l’ISO 8655-2, à la place des pipettes à un trait pour la préparation des solutions étalons, des solutions d’étalonnage et la dilution des échantillons.
7.2.4 Cuve à ultrasons, de préférence équipée d’une minuterie, permettant d’appliquer la méthode
d’extraction par ultrasons des fluorures particulaires solubles et l’acide fluorhydrique. 7.2.5 Système de chromatographie ionique, composé des éléments énumérés ci-après. Les éléments et les tuyaux de raccordement qui entrent en contact avec la solution d’échantillon ou l’éluant doivent, dans la mesure du possible, être composés de matériaux inertes, par exemple du polyétheréthercétone (PEEK):
- pompe, pouvant fournir un débit constant sur une plage comprise entre 0,1 ml/min et 5 ml/min à une pression de 15 MPa à 150 MPa;
- système de génération d’éluant, permettant de produire un éluant compatible avec la colonne de séparation sélectionnée, comme alternative à l’utilisation d’un éluant préparé manuellement (voir par exemple la Référence [15]);
- système d’injection d’échantillons, composé d’une vanne non métallique à faible volume mort, dotée d’une boucle d’injection, conçue pour injecter la solution d’échantillon dans le flux d’éluant;
- colonne de garde et de séparation, remplie d’une résine pelliculaire échangeuse d’anions d’une grande capacité, adaptée à la séparation des fluorures des autres anions inorganiques;
- module de suppression (chimique ou électronique) pour la chromatographie ionique, compatible avec la colonne de séparation;
- détecteur conductimétrique, à flux continu, de faible volume, à circuit non métallique.
ISO 21438-3:2026(fr)
8 Évaluation de l’exposition professionnelle
[10] [9] Se reporter à l'ISO 20581, l'EN 689 et l'ASTM E1370 pour obtenir des recommandations concernant la manière d’élaborer une stratégie d’évaluation appropriée, ainsi que des recommandations générales relatives à la stratégie de mesure.
...