Abstract

This document specifies a method for the determination of the time-weighted average mass concentration of hydrogen chloride (HCl) gas and hydrochloric acid mist, hydrogen bromide (HBr) vapour and hydrobromic acid mist and nitric acid (HNO3) vapour and mist in workplace air by collection on an alkali-impregnated quartz fibre filter and analysis by ion chromatography.
For mist sampling, this method is applicable to the personal sampling of the inhalable fraction of airborne particles as defined in ISO 7708 and to static (area) sampling.

Status
Published
Public Enquiry End Date
02-Aug-2026
Publication Date
27-Aug-2026
Technical Committee
KAZ - Air quality
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
06-Aug-2026
Due Date
11-Oct-2026
Completion Date
28-Aug-2026

Buy Documents

Standard

SIST ISO 21438-2:2026

English language (26 pages)
Preview
Preview
e-Library read for
×1 day
Standard

ISO 21438-2:2024 - Workplace atmospheres — Determination of inorganic acids by ion chromatography — Part 2: Volatile acids, except hydrofluoric acid (hydrochloric acid, hydrobromic acid and nitric acid) Released:26. 01. 2024

English language (20 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

ISO 21438-2:2024 - Air des lieux de travail — Détermination des acides inorganiques par chromatographie ionique — Partie 2: Acides volatils, sauf acide fluorhydrique (acide chlorhydrique, acide bromhydrique et acide nitrique) Released:26. 01. 2024

French language (21 pages)
sale 15% off
Preview
sale 15% off
Preview

SIST ISO 21438-2:2026 is the Slovenian adoption of ISO 21438-2:2024 for workplace air monitoring of inorganic acids. It specifies a filter-sampling and ion chromatography method for the time-weighted average mass concentration of hydrogen chloride, hydrogen bromide and nitric acid in air, and it is written for occupational exposure assessment in workplaces where these acids are present.

What does SIST ISO 21438-2:2026 specify?

SIST ISO 21438-2:2026 specifies how to collect and analyze workplace air samples for hydrogen chloride (HCl), hydrogen bromide (HBr) and nitric acid (HNO3). It covers both gas/vapour and mist, and for mist sampling it applies to personal sampling of the inhalable fraction and to static area sampling.

The document is organized as a full method, from scope and terms through sampling, analysis, calculation of results, performance characteristics and reporting. Its annexes support the method with temperature-pressure correction and filter-material guidance.

AnnexWhat it covers
Annex ATemperature and pressure correction for flow rate and, where needed, for reported concentrations
Annex BGuidance on suitable pre-filters and sampling filters

What are the key requirements of SIST ISO 21438-2:2026?

SIST ISO 21438-2:2026 is a complete occupational air-analytical method, so the main requirements are about representative sampling, contamination control, calibration, and result calculation. In practice, the method only works well if the sampler, filters, blanks and ion chromatograph are all handled as a controlled system.

Sampling principle and equipment

Clause 4 states that air is drawn through a pre-filter and an alkali-impregnated quartz fibre sampling filter in an inhalable sampler. The pre-filter traps particulate salts, while the sampling filter collects the volatile acids, and the collected acids are then extracted and measured by ion chromatography.

This matters because the document is designed to distinguish the acids from their salts. If salts and acids are not separated properly, the result can be biased high or low.

Clause 5 requires the measuring procedure to meet the performance requirements of ISO 20581. That means the laboratory or field team has to show that the procedure is fit for workplace chemical measurement, not just that the instrument can detect ions.

Reagents, blanks and apparatus

Clauses 6 and 7 emphasize clean reagents, clean labware and acid-compatible sampling components. The method uses ultrapure water, analytical-grade reagents, and frequent checks on blank values because chloride, bromide and nitrate can be present at low levels in chemicals, glassware and filters.

This is important in practice because blank contamination is one of the main risks in this method. The samplers, spacers, pre-filters and sampling filters must be made of materials that do not react with acids or adsorb them, and the ion chromatograph must have inert flow paths where possible.

Sampling strategy and field handling

Clause 8 points users to exposure-assessment planning. Clause 9 then sets out the practical sampling steps: select a suitable sampler and flow rate, choose a sampling period long enough for the expected exposure, and place the sampler in the breathing zone for personal sampling or at an appropriate location for static sampling.

The document also requires attention to temperature and pressure effects on flow measurement, field blanks, careful filter handling, and sample transport. In practice, users need to record the flow rate at the start and end of sampling, check whether pump performance stayed acceptable, and treat any significant drift as a possible validity issue.

Clause 9.5 adds transport and equilibration requirements. Samples are protected from contamination during transport, and filters are left to equilibrate before analysis. This helps prevent handling artefacts from affecting the reported acid concentration.

Analysis, calibration and quality control

Clause 10 describes preparation of test and calibration solutions and the ion chromatographic analysis. The method uses a multi-point calibration, linear regression, and continuing calibration checks during the batch. Reagent blanks, laboratory blanks, quality control solutions, certified reference materials and proficiency testing are all part of the control system.

This matters because the method is intended for routine workplace use, not one-off measurements only. The laboratory has to watch for drift, contamination and recovery problems, and re-analyze samples if the calibration or quality control checks show a change in sensitivity.

Clause 10.3 covers estimation of the instrumental limit of detection, the method limit of detection and the limit of quantification. Clause 10.5 recommends reporting measurement uncertainty in line with ISO/IEC Guide 98-3. In practice, that means the lab should not only give a result, but also document how sensitive and how uncertain the measurement is.

Results, performance and reporting

Clause 11 explains how to calculate the acid concentration from the measured anion concentration, including blank correction, dilution and conversion from chloride, bromide or nitrate to the corresponding acid. This is the step that turns the chromatograph result into an occupational exposure value.

Clause 12 summarizes method performance, including sampling efficiency, storage stability, quantification limits, working range, bias, precision, uncertainty and interference effects. Clause 13 lists the information that belongs in the test record and laboratory report, so the result can be traced and defended in audits or exposure assessments.

What terms does SIST ISO 21438-2:2026 define?

SIST ISO 21438-2:2026 defines the terms it uses for solutions and sample preparation so the analytical steps are unambiguous.

  • Blank solution - a solution taken through the sample dissolution procedure without a real sample, used to check contamination.
  • Calibration blank solution - a calibration solution prepared without working standard solution, treated as having zero chloride, bromide and nitrate.
  • Calibration solution - a solution made from working standard solution for setting the calibration of the ion chromatograph.
  • Extraction solution - the solvent or solution used to solubilize the analytes from the filter.
  • Sample dissolution - the process that produces a solution containing chloride, bromide and nitrate from a sample.
  • Sample solution - the solution obtained from a sample after sample dissolution.
  • Stock standard solution - a certified standard solution traceable to national standards, used to prepare calibration solutions.
  • Working standard solution - a diluted stock standard solution at a concentration better suited to making calibration solutions.

Who uses SIST ISO 21438-2:2026?

SIST ISO 21438-2:2026 is used by agencies concerned with health and safety at work, industrial hygienists, other public health professionals, analytical laboratories, and industrial users of hydrochloric acid, hydrobromic acid and nitric acid. It is also relevant to workers and employers who need exposure measurements in workplaces where these acids may be airborne.

In practice, these users apply the standard to workplace exposure assessment, sampling, laboratory analysis, compliance support and investigation of control measures. It is especially useful where a method is needed to separate volatile acids from their corresponding salts in air.

What changed in SIST ISO 21438-2:2026 from the previous edition?

SIST ISO 21438-2:2026 is the second edition and cancels and replaces ISO 21438-2:2009. The document states that the main changes are updated terms, definitions and references, plus updated information on sample preparation and analytical methodology.

Which standards are used with SIST ISO 21438-2:2026?

SIST ISO 21438-2:2026 is used together with several standards that support sampling, analysis, uncertainty and exposure assessment:

  • ISO 20581 - sets the performance requirements for procedures measuring chemical agents in workplace air.
  • ISO 7708 - defines the inhalable fraction used for mist sampling.
  • EN 13205 - gives sampler performance requirements for airborne particle concentrations.
  • ISO 18158 - provides workplace-air terminology used for the terms and definitions.
  • ISO 1042, ISO 3585, ISO 3696 and ISO 8655-1/2/6 - support the glassware, water and volumetric apparatus used in solution preparation.
  • ISO 21832:2018 - is referenced for working-range and limit-of-quantification guidance and for evaluating measuring procedures.
  • ISO 13137 - is used for sampling pumps in the sampling equipment section.
  • ISO 8756 and ISO/IEC Guide 98-3 - support temperature-pressure handling and measurement uncertainty.
  • EN 689 and ASTM E1370 - are cited for exposure-assessment strategy.
  • ASTM D4840 and ASTM E882 - support chain of custody and quality-control charting.

What does the SIST ISO 21438-2:2026 document contain?

SIST ISO 21438-2:2026 contains a complete field-to-laboratory procedure, including a filter-loading figure, sampling guidance, calibration and quality-control steps, and calculation formulas for flow correction and concentration reporting. It also includes practical instructions on blank control, sample handling, storage, dilution, continuing calibration verification, and uncertainty estimation.

The annexes add the supporting technical details that many laboratories need but that would interrupt the main method, such as correction for temperature and pressure and guidance on suitable filter materials. The reporting clause then turns the method into an auditable record by listing the sampling, analytical and quality-control information that belongs in the test record and laboratory report.

Buy Documents

Standard

SIST ISO 21438-2:2026

English language (26 pages)
Preview
Preview
e-Library read for
×1 day
Standard

ISO 21438-2:2024 - Workplace atmospheres — Determination of inorganic acids by ion chromatography — Part 2: Volatile acids, except hydrofluoric acid (hydrochloric acid, hydrobromic acid and nitric acid) Released:26. 01. 2024

English language (20 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

ISO 21438-2:2024 - Air des lieux de travail — Détermination des acides inorganiques par chromatographie ionique — Partie 2: Acides volatils, sauf acide fluorhydrique (acide chlorhydrique, acide bromhydrique et acide nitrique) Released:26. 01. 2024

French language (21 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

ECOCERT

Organic and sustainability certification.

COFRAC France Verified

CIS Institut d.o.o.

Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

SA Slovenia Verified

Eurofins Food Testing Global

Global leader in food, environment, and pharmaceutical product testing.

COFRAC Luxembourg Verified

Sponsored listings

Frequently Asked Questions

SIST ISO 21438-2:2026 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Workplace atmospheres - Determination of inorganic acids by ion chromatography - Part 2: Volatile acids, except hydrofluoric acid (hydrochloric acid, hydrobromic acid and nitric acid)". This standard covers: This document specifies a method for the determination of the time-weighted average mass concentration of hydrogen chloride (HCl) gas and hydrochloric acid mist, hydrogen bromide (HBr) vapour and hydrobromic acid mist and nitric acid (HNO3) vapour and mist in workplace air by collection on an alkali-impregnated quartz fibre filter and analysis by ion chromatography. For mist sampling, this method is applicable to the personal sampling of the inhalable fraction of airborne particles as defined in ISO 7708 and to static (area) sampling.

This document specifies a method for the determination of the time-weighted average mass concentration of hydrogen chloride (HCl) gas and hydrochloric acid mist, hydrogen bromide (HBr) vapour and hydrobromic acid mist and nitric acid (HNO3) vapour and mist in workplace air by collection on an alkali-impregnated quartz fibre filter and analysis by ion chromatography. For mist sampling, this method is applicable to the personal sampling of the inhalable fraction of airborne particles as defined in ISO 7708 and to static (area) sampling.

SIST ISO 21438-2:2026 is classified under the following ICS (International Classification for Standards) categories: 13.040.30 - Workplace atmospheres; 71.040.50 - Physicochemical methods of analysis; 71.060.30 - Acids. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST ISO 21438-2:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 blank solution
  • 3.2 calibration blank solution
  • 3.3 calibration solution
  • 3.4 extraction solution
  • 3.5 sample dissolution
  • 3.6 sample solution
  • 3.7 stock standard solution
  • 3.8 test solution
  • 3.9 working standard solution
  • 4 Principle
  • 5 Requirement
  • 6 Reagents
  • 7 Apparatus
  • 7.1 Sampling equipment
  • 7.2 Laboratory apparatus
  • 8 Occupational exposure assessment
  • 9 Sampling
  • 9.1 Preliminary considerations
  • 9.2 Preparation for sampling
  • 9.3 Sampling position
  • 9.4 Collection of samples
  • 9.5 Transportation
  • 10 Analysis
  • 10.1 Preparation of test and calibration solutions, and filter samples
  • 10.2 Instrumental analysis
  • 10.3 Estimation of limits of detection and quantification
  • 10.4 Quality control
  • 10.5 Measurement uncertainty
  • 11 Expression of results
  • 12 Method performance
  • 12.1 Sampling efficiency and sample storage
  • 12.2 Limits of quantification
  • 12.3 Upper limits of the working range
  • 12.4 Bias and precision
  • 12.5 Uncertainty of sampling and analysis method
  • 12.6 Interferences
  • 13 Test report
  • 13.1 Test record
  • 13.2 Laboratory report
  • Annex A
  • Annex B
  • Bibliography

Introduction

The health of workers in many industries is at risk through exposure by inhalation of volatile inorganic acids. Industrial hygienists and other public health professionals need to determine the effectiveness of measures taken to control workers' exposure and this is generally achieved by making workplace air measurements. This document has been published in order to make available a method for making valid exposure measurements for volatile inorganic acids in use in the industry, such as hydrochloric acid, hydrobromic acid and nitric acid, but excluding hydrofluoric acid. This document is intended to be of benefit to:

  • agencies concerned with health and safety at work;
  • industrial hygienists and other public health professionals;
  • analytical laboratories;
  • industrial users of hydrochloric acid, hydrobromic acid and nitric acid and their workers, etc. The execution of the provisions and the interpretation of the results obtained with the use of this document are entrusted to appropriately qualified and experienced people. The procedure is intended to differentiate between the acids and their corresponding salts. If both are present in the air, particulate salts are trapped on a pre-filter. Co-sampled particulate matter either trapped on the pre-filter or deposited on the walls of the sampler, or both, can be analysed, if desired. Acids can react with co-sampled particulate matter on the pre-filter, causing interference with the measurement of the acid concentration.

SIST ISO 21438-2:2026 International Standard ISO 21438-2:2024(en) Workplace atmospheres — Determination of inorganic acids by ion chromatography — Part 2:

Volatile acids, except hydrofluoric acid (hydrochloric acid, hydrobromic acid and nitric acid)

1 Scope

This document specifies a method for the determination of the time-weighted average mass concentration of hydrogen chloride (HCl) gas and hydrochloric acid mist, hydrogen bromide (HBr) vapour and hydrobromic acid mist and nitric acid (HNO ) vapour and mist in workplace air by collection on an alkali-impregnated

quartz fibre filter and analysis by ion chromatography.

For mist sampling, this method is applicable to the personal sampling of the inhalable fraction of airborne particles as defined in ISO 7708 and to static (area) sampling.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 1042, Laboratory glassware — One-mark volumetric flasks ISO 3585, Borosilicate glass 3.3 — Properties ISO 3696, Water for analytical laboratory use — Specification and test methods ISO 7708, Air quality — Particle size fraction definitions for health-related sampling ISO 8655-1, Piston-operated volumetric apparatus — Part 1: Terminology, general requirements and user recommendations ISO 8655-2, Piston-operated volumetric apparatus — Part 2: Pipettes ISO 8655-6, Piston-operated volumetric apparatus — Part 6: Gravimetric reference measurement procedure for the determination of volume ISO 18158, Workplace air — Terminology ISO 20581, Workplace air — General requirements for the performance of procedures for the measurement of chemical agents ISO 21832:2018, Workplace air — Metals and metalloids in airborne particles — Requirements for evaluation of measuring procedures EN 13205, Workplace exposure — Assessment of sampler performance for measurement of airborne particle concentrations

SIST ISO 21438-2:2026 ISO 21438-2:2024(en)

3 Terms and definitions

For the purposes of this document, the terms and definitions given in ISO 18158 and the following apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https:// www .iso .org/ obp
  • IEC Electropedia: available at https:// www .electropedia .org/

3.1 blank solution

solution prepared by taking a reagent blank, laboratory blank or field blank through the same procedure used for sample dissolution (3.5)

3.2 calibration blank solution

calibration solution (3.3) prepared without the addition of any working standard solution (3.9) Note 1 to entry: The concentration of chloride, bromide and nitrate in the calibration blank solution is taken to be zero.

3.3 calibration solution

solution prepared by dilution of the working standard solution (3.9), containing chloride, bromide and nitrate at concentrations that are suitable for use in calibration of the analytical instrument

3.4 extraction solution

solvent or solution used to solubilise the analyte(s) of interest

3.5 sample dissolution

process of obtaining a solution containing chloride, bromide and nitrate from a sample, which does or does not involve complete dissolution of the sample

3.6 sample solution

solution prepared from a sample by the process of sample dissolution (3.5) Note 1 to entry: A sample solution can require further operations, for example, dilution, in order to produce a test solution (3.8) that is ready for analysis.

3.7 stock standard solution

solution, used for preparation of the calibration solutions (3.3), containing chloride, bromide and/or nitrate at a certified concentration that is traceable to national standards

3.8 test solution

blank solution (3.1) or sample solution (3.6) that has been subjected to all operations required to bring it into a state in which it is ready for analysis, e.g. dilution, filtered Note 1 to entry: The blank test solution is the blank solution and the sample test solution is the sample solution if these solutions are not subjected to any further operations before analysis.

3.9 working standard solution

solution, prepared by dilution of the stock standard solution(s) (3.7), that contains chloride, bromide and nitrate at concentrations that are better suited to the preparation of calibration solutions (3.3) than the concentrations of chloride, bromide and nitrate in the stock standard solution(s)

SIST ISO 21438-2:2026 ISO 21438-2:2024(en)

4 Principle

A known volume of air is drawn through a pre-filter and an alkali-impregnated quartz fibre sampling filter mounted in an inhalable sampler to collect HCl, HBr and HNO . The acids are collected on the sampling filter,

while particulate salts of the acids are trapped on the pre-filter. The acids collected on the sampling filter are extracted with water or eluent (see 10.1.2), without heating, to solubilize the analytes of interest.

Aliquots of the sample solution are subjected to ion chromatography in order to separate the extracted chloride, nitrate or bromide from other anions. Following this separation, the anions are measured using a conductivity or UV/visible detector.

Analytical results are obtained by plotting the measured signal as a function of concentration. They can be used for assessing the occupational exposure to HCl, HBr and HNO in the air.

5 Requirement

The measuring procedure shall comply with the performance requirements for procedures for measuring chemical agents in workplace air given in ISO 20581.

6 Reagents

Use only reagents of recognized analytical grade and only water as specified in 6.1. It is advisable to check the blank values of all chemicals before use.

NOTE Chlorides and nitrates are found ubiquitously in the environment, and the presence of chloride and nitrate in reagents can lead to high blank values. It is therefore advisable to check the blank values of all chemicals before use. 6.1 Water, from a purification system that delivers ultrapure water of grade 1, in accordance with the requirements of ISO 3696.

NOTE State-of-art water purification systems deliver water of grade 1 with higher quality than specified in ISO 3696 (e.g. resistivity greater than 18 MΩ·cm).

6.2 Sodium carbonate (Na CO ), anhydrous, mass fraction greater than 99,9 %. 2 3 6.3 Sodium carbonate solution, 1 mol/l, for impregnation of 37 mm diameter quartz fibre filters. Dissolve 10,6 g of Na CO (6.2) in water. Quantitatively transfer the solution into a 100 ml one-mark 2 3 volumetric flask, dilute to the mark with water, stopper and mix thoroughly. 6.4 Sodium bicarbonate (NaHCO ), anhydrous, mass fraction greater than 99,9 %.

6.5 Sodium carbonate/sodium bicarbonate extraction and eluent stock solution. Create a stock solution for the extraction and eluent solution. The stock solution shall be appropriate to the used application.

6.6 Sodium carbonate/sodium bicarbonate extraction and eluent solution. The concentration of the extraction and eluent solution are typically matched, but this can be modified according to the laboratory procedure.

NOTE An alkaline solution (potassium hydroxide or sodium hydroxide) can be used in place of the buffer solution according to modifications to the method, but the resulting solution will require adjustment before analysis.

SIST ISO 21438-2:2026 ISO 21438-2:2024(en) 6.7 Chloride, bromide and nitrate standard solutions.

6.7.1 Chloride, bromide and nitrate stock solutions.

Use a commercial standard solution with a certificate of its concentration, e.g. 1 000 mg/l, traceable to national standards. Observe the manufacturer's expiry date or recommended shelf-life. If necessary, dilute the standard solution (e.g. from 1 000 mg/l to 100 mg/l) to prepare the working standard solution. 6.7.2 Chloride, bromide and nitrate calibration solutions.

Pipette appropriate volumes of the stock solution or working standard solution to create the calibration. The calibration range shall be in accordance with the calculated working range in ISO 21832:2018, 5.2.1, and the limit of quantification (LOQ) in ISO 21832:2018, 8.1.2. A multi-point (i.e. the number of points to be consistent with the quality system of the laboratory) calibration shall be constructed within the linear range of the analytical method.

6.8 Chloride, bromide and nitrate check-standard.

Use a certified reference material (CRM) as described in 10.4.3 with a certificate of its concentration, for example, 200 mg/l for chloride, 400 mg/l for bromide and 400 mg/l for nitrate, traceable to national standards. Observe the manufacturer's expiry date or recommended shelf-life. 6.9 Chloride, bromide and nitrate check-standard working solution. The check-standard working solution should be in the middle of the calibration range. Pipette a proper volume of check-standard (6.8) to create a check-standard working solution with the eluent (6.6). Prepare this solution fresh for every calibration. If necessary, create a check-standard working solution for chloride, bromide and nitrate separately.

7 Apparatus

7.1 Sampling equipment

7.1.1 Samplers, designed to collect the inhalable fraction of airborne particles, complying with EN 13205, suitable for mounting a pre-filter and sampling filter separated by a spacer, manufactured from a material that does not react with acids.

NOTE 1 If samplers have an internal filter cassette, this too has to be manufactured from a material that does not react with acids.

NOTE 2 Materials which do not react with acids, from which samplers and internal filter cassettes can be manufactured, include polytetrafluoroethylene (PTFE) and other fluorinated polymers, polyvinyl chloride (PVC), polyethylene, polypropylene and polycarbonate.

[9] NOTE 3 CEN/TR 15230 gives examples of inhalable samplers with the potential to meet the requirements of EN 13205 that were available on the market up to 2004, including a list of published reports on their performance. 7.1.2 Filters, of a diameter suitable for use with the samplers (7.1.1). Hydrogen chloride (HCl) gas and hydrochloric acid mist, hydrogen bromide (HBr) vapour and hydrobromic acid mist and nitric acid (HNO ) vapour and mist are strong acids. Therefore, correct selection of the filter

used for sample collection is of paramount importance. Also, some filters, for example, glass fibre filters, can contain metals, for example, barium, that react with acids to produce insoluble salts. Chloride, bromide and nitrate are found ubiquitously in the environment and the presence of chloride, bromide and nitrate in filter materials can lead to high blank values. It is therefore essential to check the blank values of each batch of filters used.

SIST ISO 21438-2:2026 ISO 21438-2:2024(en)

7.1.2.1 Pre-filters, of a diameter suitable for use with the samplers (7.1.1), with a collection

efficiency ≥99 % for particles with a 0,3 µm diffusion diameter and manufactured from a material that does not react with HCl, HBr or HNO , for use as pre-filters to remove interfering particulate salts and also is

compatible with the sample preparation and analysis method.

Refer to Clause B.1 for guidance on suitable materials from which pre-filters can be manufactured. 7.1.2.2 Sampling filters, such as quartz fibre, impregnated with sodium carbonate solution, for use as sampling filters for volatile inorganic acids; e.g. 25 mm diameter filters impregnated with 200 µl of 2,5 mol/l sodium carbonate solution or 37 mm diameter filters impregnated with 500 µl of 1 mol/l sodium carbonate solution (6.3) (see References [10] and [11]).

Refer to Clause B.2 for guidance on materials from which sampling filters can be manufactured. 7.1.3 Spacers, of a diameter suitable for use with the samplers (7.1.1), for separating the pre-filters (7.1.2.1) and sampling filters (7.1.2.2), manufactured from an inert material that does not react with the acids and on which the acids are not adsorbed, e.g. polypropylene sleeves or PTFE-coated screens. [1] 7.1.4 Sampling pumps, according to ISO 13137 should be used.

[1] If the sampling pump is used outside the range of conditions specified in ISO 13137 appropriate action should be taken to ensure that the performance requirements are met. For instance, at sub-zero temperatures it can be necessary to keep the pump warm.

7.1.5 Flow meter, portable, with an accuracy that is sufficient to enable the volumetric flow rate to be measured to within ±5 %.

The calibration of the flow meter shall be checked against a primary standard, i.e. a flow meter whose accuracy is traceable to national standards. If appropriate (see 9.1.3), record the atmospheric temperature and pressure at which the calibration of the flow meter was checked. It is advisable that the flow meter used be capable of measuring the volumetric flow rate to within ±2 % or better.

7.1.6 Ancillary equipment.

  • Flexible tubing, for example, silicone of an outer diameter of 10 mm and an inner diameter of 6 mm for making a leakproof connection from the samplers to the sampling pumps without compressing as a result of the pressure difference between ambient atmosphere and the in-line vacuum at the used flow rate.
  • Belts or harnesses, which the sampling pumps can conveniently fix for personal sampling.
  • Tweezers manufactured from or tipped with PTFE, for handling filters.
  • Filter transport cassettes, or similar, if required (see 9.5.1), in which to transport samples to the laboratory.
  • Thermometer, of range 0 °C to 50 °C, graduated in divisions of 1 °C or less, for measurement of atmospheric temperature. For applications at temperatures below freezing, the range of the thermometer shall extend to the appropriate desired range.
  • Barometer, suitable for measurement of atmospheric pressure.

7.2 Laboratory apparatus

CAUTION — Chlorides, nitrates and, to a minor degree, bromides are found ubiquitously in the environment, and the presence of chlorides, in particular, can lead to elevated blanks. Check all disposable labware for chloride, nitrate and bromide contamination before use and clean all reusable laboratory apparatus thoroughly.

SIST ISO 21438-2:2026 ISO 21438-2:2024(en) 7.2.1 Disposable gloves, impermeable, to avoid the possibility of contamination from the hands and to protect them from contact with toxic and corrosive substances. PVC gloves are suitable. 7.2.2 Glassware, made of borosilicate glass 3,3, complying with the requirements of ISO 3585, cleaned before use with water (6.1).

Alternatively, the glassware may be cleaned with a suitable phosphate-free laboratory detergent using a laboratory washing machine and afterwards rinsed thoroughly with water (6.1). 7.2.3 One-mark volumetric flasks, of capacities up to 2 l, complying with the requirements of ISO 1042. 7.2.4 Plastic labware.

  • Screw-cap polyethylene vessels appropriate for the extraction of collected sample filters.
  • Beakers of appropriate capacity.
  • Disposable filters of PTFE, of pore size 0,45 µm and for use in ion chromatography.
  • Disposable syringes of appropriate capacity and with appropriate needles.
  • Autosampler vials of appropriate capacity.

7.2.5 Piston-operated volumetric instruments, of capacities of 50 µl to 10 ml, complying with the requirements of ISO 8655-1, and tested in accordance with the requirements of ISO 8655-6; pipettors, complying with the requirements of ISO 8655-2, as an alternative to one-mark pipettes for the preparation of standard solutions, calibration solutions and dilution of samples. 7.2.6 Ultrasonic bath, preferably with a timer, suitable for use in the ultrasonic extraction method for HCl, HBr and HNO and for degassing the eluent solutions.

7.2.7 Ion chromatograph, having the following components:

  • pump, capable of delivering a constant flow within the range 0,1 ml/min to 5 ml/min at a pressure of 15 MPa to 150 MPa;
  • eluent generation system for the production of a suitable eluent for use with the selected separator column, as an alternative to use of a manually prepared eluent (e.g. see Reference [18]);
  • sample injection system, comprising a low dead-volume, non-metallic valve fitted with a sample loop, for injecting the sample solution into the eluent stream;
  • guard and separator column, packed with high capacity pellicular anion exchange resin, suitable for resolving chloride, nitrate and bromide from other inorganic anions;
  • suppressor module (chemically or electronically suppressed) for ion chromatography, suitable for use with the separator column;
  • conductivity detector, flow through, low volume, with a non-metallic flow path. Components and tubing that come into contact with the sample solution or eluent shall, as far as possible, be comprising inert materials, e.g. polyetheretherketone (PEEK).

8 Occupational exposure assessment

[4] [5] Refer to ISO 20581, EN 689 and ASTM E1370 for guidance on how to develop an appropriate assessment strategy and for general guidance on measurement strategy.

SIST ISO 21438-2:2026 ISO 21438-2:2024(en)

9 Sampling

9.1 Preliminary considerations

9.1.1 Selection and use of samplers

Select samplers (7.1.1) in accordance with the requirements of the applicable limit value. Size selective samplers shall be designed to collect the appropriate fraction of airborne particles as defined in ISO 7708 and tested in accordance with EN 13205.

If possible, the samplers selected should be manufactured from conducting material, since samplers manufactured from non-conducting material have electrostatic properties that can influence the representative nature of the sampling.

If the samplers selected have an internal filter cassette or cartridge that has to be rinsed during sample preparation, this cassette shall be manufactured from a material that does not react with acids. Use the samplers at their design flow rate and in accordance with the instructions provided by the manufacturer. See Reference [9] for further guidance.

9.1.2 Sampling period

Select a sampling period that is appropriate for the measurement task (see Clause 8) but ensure that it is long enough to enable HCl, HBr or HNO in the air to be determined with acceptable uncertainty at levels

...

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 blank solution
  • 3.2 calibration blank solution
  • 3.3 calibration solution
  • 3.4 extraction solution
  • 3.5 sample dissolution
  • 3.6 sample solution
  • 3.7 stock standard solution
  • 3.8 test solution
  • 3.9 working standard solution
  • 4 Principle
  • 5 Requirement
  • 6 Reagents
  • 7 Apparatus
  • 7.1 Sampling equipment
  • 7.2 Laboratory apparatus
  • 8 Occupational exposure assessment
  • 9 Sampling
  • 9.1 Preliminary considerations
  • 9.2 Preparation for sampling
  • 9.3 Sampling position
  • 9.4 Collection of samples
  • 9.5 Transportation
  • 10 Analysis
  • 10.1 Preparation of test and calibration solutions, and filter samples
  • 10.2 Instrumental analysis
  • 10.3 Estimation of limits of detection and quantification
  • 10.4 Quality control
  • 10.5 Measurement uncertainty
  • 11 Expression of results
  • 12 Method performance
  • 12.1 Sampling efficiency and sample storage
  • 12.2 Limits of quantification
  • 12.3 Upper limits of the working range
  • 12.4 Bias and precision
  • 12.5 Uncertainty of sampling and analysis method
  • 12.6 Interferences
  • 13 Test report
  • 13.1 Test record
  • 13.2 Laboratory report
  • Annex A
  • Annex B
  • Bibliography

Introduction

The health of workers in many industries is at risk through exposure by inhalation of volatile inorganic acids. Industrial hygienists and other public health professionals need to determine the effectiveness of measures taken to control workers' exposure and this is generally achieved by making workplace air measurements. This document has been published in order to make available a method for making valid exposure measurements for volatile inorganic acids in use in the industry, such as hydrochloric acid, hydrobromic acid and nitric acid, but excluding hydrofluoric acid. This document is intended to be of benefit to:

  • agencies concerned with health and safety at work;
  • industrial hygienists and other public health professionals;
  • analytical laboratories;
  • industrial users of hydrochloric acid, hydrobromic acid and nitric acid and their workers, etc. The execution of the provisions and the interpretation of the results obtained with the use of this document are entrusted to appropriately qualified and experienced people. The procedure is intended to differentiate between the acids and their corresponding salts. If both are present in the air, particulate salts are trapped on a pre-filter. Co-sampled particulate matter either trapped on the pre-filter or deposited on the walls of the sampler, or both, can be analysed, if desired. Acids can react with co-sampled particulate matter on the pre-filter, causing interference with the measurement of the acid concentration.

International Standard ISO 21438-2:2024(en) Workplace atmospheres — Determination of inorganic acids by ion chromatography — Part 2:

Volatile acids, except hydrofluoric acid (hydrochloric acid, hydrobromic acid and nitric acid)

1 Scope

This document specifies a method for the determination of the time-weighted average mass concentration of hydrogen chloride (HCl) gas and hydrochloric acid mist, hydrogen bromide (HBr) vapour and hydrobromic acid mist and nitric acid (HNO ) vapour and mist in workplace air by collection on an alkali-impregnated

quartz fibre filter and analysis by ion chromatography.

For mist sampling, this method is applicable to the personal sampling of the inhalable fraction of airborne particles as defined in ISO 7708 and to static (area) sampling.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 1042, Laboratory glassware — One-mark volumetric flasks ISO 3585, Borosilicate glass 3.3 — Properties ISO 3696, Water for analytical laboratory use — Specification and test methods ISO 7708, Air quality — Particle size fraction definitions for health-related sampling ISO 8655-1, Piston-operated volumetric apparatus — Part 1: Terminology, general requirements and user recommendations ISO 8655-2, Piston-operated volumetric apparatus — Part 2: Pipettes ISO 8655-6, Piston-operated volumetric apparatus — Part 6: Gravimetric reference measurement procedure for the determination of volume ISO 18158, Workplace air — Terminology ISO 20581, Workplace air — General requirements for the performance of procedures for the measurement of chemical agents ISO 21832:2018, Workplace air — Metals and metalloids in airborne particles — Requirements for evaluation of measuring procedures EN 13205, Workplace exposure — Assessment of sampler performance for measurement of airborne particle concentrations

ISO 21438-2:2024(en)

3 Terms and definitions

For the purposes of this document, the terms and definitions given in ISO 18158 and the following apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https:// www .iso .org/ obp
  • IEC Electropedia: available at https:// www .electropedia .org/

3.1 blank solution

solution prepared by taking a reagent blank, laboratory blank or field blank through the same procedure used for sample dissolution (3.5)

3.2 calibration blank solution

calibration solution (3.3) prepared without the addition of any working standard solution (3.9) Note 1 to entry: The concentration of chloride, bromide and nitrate in the calibration blank solution is taken to be zero.

3.3 calibration solution

solution prepared by dilution of the working standard solution (3.9), containing chloride, bromide and nitrate at concentrations that are suitable for use in calibration of the analytical instrument

3.4 extraction solution

solvent or solution used to solubilise the analyte(s) of interest

3.5 sample dissolution

process of obtaining a solution containing chloride, bromide and nitrate from a sample, which does or does not involve complete dissolution of the sample

3.6 sample solution

solution prepared from a sample by the process of sample dissolution (3.5) Note 1 to entry: A sample solution can require further operations, for example, dilution, in order to produce a test solution (3.8) that is ready for analysis.

3.7 stock standard solution

solution, used for preparation of the calibration solutions (3.3), containing chloride, bromide and/or nitrate at a certified concentration that is traceable to national standards

3.8 test solution

blank solution (3.1) or sample solution (3.6) that has been subjected to all operations required to bring it into a state in which it is ready for analysis, e.g. dilution, filtered Note 1 to entry: The blank test solution is the blank solution and the sample test solution is the sample solution if these solutions are not subjected to any further operations before analysis.

3.9 working standard solution

solution, prepared by dilution of the stock standard solution(s) (3.7), that contains chloride, bromide and nitrate at concentrations that are better suited to the preparation of calibration solutions (3.3) than the concentrations of chloride, bromide and nitrate in the stock standard solution(s)

ISO 21438-2:2024(en)

4 Principle

A known volume of air is drawn through a pre-filter and an alkali-impregnated quartz fibre sampling filter mounted in an inhalable sampler to collect HCl, HBr and HNO . The acids are collected on the sampling filter,

while particulate salts of the acids are trapped on the pre-filter. The acids collected on the sampling filter are extracted with water or eluent (see 10.1.2), without heating, to solubilize the analytes of interest.

Aliquots of the sample solution are subjected to ion chromatography in order to separate the extracted chloride, nitrate or bromide from other anions. Following this separation, the anions are measured using a conductivity or UV/visible detector.

Analytical results are obtained by plotting the measured signal as a function of concentration. They can be used for assessing the occupational exposure to HCl, HBr and HNO in the air.

5 Requirement

The measuring procedure shall comply with the performance requirements for procedures for measuring chemical agents in workplace air given in ISO 20581.

6 Reagents

Use only reagents of recognized analytical grade and only water as specified in 6.1. It is advisable to check the blank values of all chemicals before use.

NOTE Chlorides and nitrates are found ubiquitously in the environment, and the presence of chloride and nitrate in reagents can lead to high blank values. It is therefore advisable to check the blank values of all chemicals before use. 6.1 Water, from a purification system that delivers ultrapure water of grade 1, in accordance with the requirements of ISO 3696.

NOTE State-of-art water purification systems deliver water of grade 1 with higher quality than specified in ISO 3696 (e.g. resistivity greater than 18 MΩ·cm).

6.2 Sodium carbonate (Na CO ), anhydrous, mass fraction greater than 99,9 %. 2 3 6.3 Sodium carbonate solution, 1 mol/l, for impregnation of 37 mm diameter quartz fibre filters. Dissolve 10,6 g of Na CO (6.2) in water. Quantitatively transfer the solution into a 100 ml one-mark 2 3 volumetric flask, dilute to the mark with water, stopper and mix thoroughly. 6.4 Sodium bicarbonate (NaHCO ), anhydrous, mass fraction greater than 99,9 %.

6.5 Sodium carbonate/sodium bicarbonate extraction and eluent stock solution. Create a stock solution for the extraction and eluent solution. The stock solution shall be appropriate to the used application.

6.6 Sodium carbonate/sodium bicarbonate extraction and eluent solution. The concentration of the extraction and eluent solution are typically matched, but this can be modified according to the laboratory procedure.

NOTE An alkaline solution (potassium hydroxide or sodium hydroxide) can be used in place of the buffer solution according to modifications to the method, but the resulting solution will require adjustment before analysis.

ISO 21438-2:2024(en) 6.7 Chloride, bromide and nitrate standard solutions.

6.7.1 Chloride, bromide and nitrate stock solutions.

Use a commercial standard solution with a certificate of its concentration, e.g. 1 000 mg/l, traceable to national standards. Observe the manufacturer's expiry date or recommended shelf-life. If necessary, dilute the standard solution (e.g. from 1 000 mg/l to 100 mg/l) to prepare the working standard solution. 6.7.2 Chloride, bromide and nitrate calibration solutions.

Pipette appropriate volumes of the stock solution or working standard solution to create the calibration. The calibration range shall be in accordance with the calculated working range in ISO 21832:2018, 5.2.1, and the limit of quantification (LOQ) in ISO 21832:2018, 8.1.2. A multi-point (i.e. the number of points to be consistent with the quality system of the laboratory) calibration shall be constructed within the linear range of the analytical method.

6.8 Chloride, bromide and nitrate check-standard.

Use a certified reference material (CRM) as described in 10.4.3 with a certificate of its concentration, for example, 200 mg/l for chloride, 400 mg/l for bromide and 400 mg/l for nitrate, traceable to national standards. Observe the manufacturer's expiry date or recommended shelf-life. 6.9 Chloride, bromide and nitrate check-standard working solution. The check-standard working solution should be in the middle of the calibration range. Pipette a proper volume of check-standard (6.8) to create a check-standard working solution with the eluent (6.6). Prepare this solution fresh for every calibration. If necessary, create a check-standard working solution for chloride, bromide and nitrate separately.

7 Apparatus

7.1 Sampling equipment

7.1.1 Samplers, designed to collect the inhalable fraction of airborne particles, complying with EN 13205, suitable for mounting a pre-filter and sampling filter separated by a spacer, manufactured from a material that does not react with acids.

NOTE 1 If samplers have an internal filter cassette, this too has to be manufactured from a material that does not react with acids.

NOTE 2 Materials which do not react with acids, from which samplers and internal filter cassettes can be manufactured, include polytetrafluoroethylene (PTFE) and other fluorinated polymers, polyvinyl chloride (PVC), polyethylene, polypropylene and polycarbonate.

[9] NOTE 3 CEN/TR 15230 gives examples of inhalable samplers with the potential to meet the requirements of EN 13205 that were available on the market up to 2004, including a list of published reports on their performance. 7.1.2 Filters, of a diameter suitable for use with the samplers (7.1.1). Hydrogen chloride (HCl) gas and hydrochloric acid mist, hydrogen bromide (HBr) vapour and hydrobromic acid mist and nitric acid (HNO ) vapour and mist are strong acids. Therefore, correct selection of the filter

used for sample collection is of paramount importance. Also, some filters, for example, glass fibre filters, can contain metals, for example, barium, that react with acids to produce insoluble salts. Chloride, bromide and nitrate are found ubiquitously in the environment and the presence of chloride, bromide and nitrate in filter materials can lead to high blank values. It is therefore essential to check the blank values of each batch of filters used.

ISO 21438-2:2024(en)

7.1.2.1 Pre-filters, of a diameter suitable for use with the samplers (7.1.1), with a collection

efficiency ≥99 % for particles with a 0,3 µm diffusion diameter and manufactured from a material that does not react with HCl, HBr or HNO , for use as pre-filters to remove interfering particulate salts and also is

compatible with the sample preparation and analysis method.

Refer to Clause B.1 for guidance on suitable materials from which pre-filters can be manufactured. 7.1.2.2 Sampling filters, such as quartz fibre, impregnated with sodium carbonate solution, for use as sampling filters for volatile inorganic acids; e.g. 25 mm diameter filters impregnated with 200 µl of 2,5 mol/l sodium carbonate solution or 37 mm diameter filters impregnated with 500 µl of 1 mol/l sodium carbonate solution (6.3) (see References [10] and [11]).

Refer to Clause B.2 for guidance on materials from which sampling filters can be manufactured. 7.1.3 Spacers, of a diameter suitable for use with the samplers (7.1.1), for separating the pre-filters (7.1.2.1) and sampling filters (7.1.2.2), manufactured from an inert material that does not react with the acids and on which the acids are not adsorbed, e.g. polypropylene sleeves or PTFE-coated screens. [1] 7.1.4 Sampling pumps, according to ISO 13137 should be used.

[1] If the sampling pump is used outside the range of conditions specified in ISO 13137 appropriate action should be taken to ensure that the performance requirements are met. For instance, at sub-zero temperatures it can be necessary to keep the pump warm.

7.1.5 Flow meter, portable, with an accuracy that is sufficient to enable the volumetric flow rate to be measured to within ±5 %.

The calibration of the flow meter shall be checked against a primary standard, i.e. a flow meter whose accuracy is traceable to national standards. If appropriate (see 9.1.3), record the atmospheric temperature and pressure at which the calibration of the flow meter was checked. It is advisable that the flow meter used be capable of measuring the volumetric flow rate to within ±2 % or better.

7.1.6 Ancillary equipment.

  • Flexible tubing, for example, silicone of an outer diameter of 10 mm and an inner diameter of 6 mm for making a leakproof connection from the samplers to the sampling pumps without compressing as a result of the pressure difference between ambient atmosphere and the in-line vacuum at the used flow rate.
  • Belts or harnesses, which the sampling pumps can conveniently fix for personal sampling.
  • Tweezers manufactured from or tipped with PTFE, for handling filters.
  • Filter transport cassettes, or similar, if required (see 9.5.1), in which to transport samples to the laboratory.
  • Thermometer, of range 0 °C to 50 °C, graduated in divisions of 1 °C or less, for measurement of atmospheric temperature. For applications at temperatures below freezing, the range of the thermometer shall extend to the appropriate desired range.
  • Barometer, suitable for measurement of atmospheric pressure.

7.2 Laboratory apparatus

CAUTION — Chlorides, nitrates and, to a minor degree, bromides are found ubiquitously in the environment, and the presence of chlorides, in particular, can lead to elevated blanks. Check all disposable labware for chloride, nitrate and bromide contamination before use and clean all reusable laboratory apparatus thoroughly.

ISO 21438-2:2024(en) 7.2.1 Disposable gloves, impermeable, to avoid the possibility of contamination from the hands and to protect them from contact with toxic and corrosive substances. PVC gloves are suitable. 7.2.2 Glassware, made of borosilicate glass 3,3, complying with the requirements of ISO 3585, cleaned before use with water (6.1).

Alternatively, the glassware may be cleaned with a suitable phosphate-free laboratory detergent using a laboratory washing machine and afterwards rinsed thoroughly with water (6.1). 7.2.3 One-mark volumetric flasks, of capacities up to 2 l, complying with the requirements of ISO 1042. 7.2.4 Plastic labware.

  • Screw-cap polyethylene vessels appropriate for the extraction of collected sample filters.
  • Beakers of appropriate capacity.
  • Disposable filters of PTFE, of pore size 0,45 µm and for use in ion chromatography.
  • Disposable syringes of appropriate capacity and with appropriate needles.
  • Autosampler vials of appropriate capacity.

7.2.5 Piston-operated volumetric instruments, of capacities of 50 µl to 10 ml, complying with the requirements of ISO 8655-1, and tested in accordance with the requirements of ISO 8655-6; pipettors, complying with the requirements of ISO 8655-2, as an alternative to one-mark pipettes for the preparation of standard solutions, calibration solutions and dilution of samples. 7.2.6 Ultrasonic bath, preferably with a timer, suitable for use in the ultrasonic extraction method for HCl, HBr and HNO and for degassing the eluent solutions.

7.2.7 Ion chromatograph, having the following components:

  • pump, capable of delivering a constant flow within the range 0,1 ml/min to 5 ml/min at a pressure of 15 MPa to 150 MPa;
  • eluent generation system for the production of a suitable eluent for use with the selected separator column, as an alternative to use of a manually prepared eluent (e.g. see Reference [18]);
  • sample injection system, comprising a low dead-volume, non-metallic valve fitted with a sample loop, for injecting the sample solution into the eluent stream;
  • guard and separator column, packed with high capacity pellicular anion exchange resin, suitable for resolving chloride, nitrate and bromide from other inorganic anions;
  • suppressor module (chemically or electronically suppressed) for ion chromatography, suitable for use with the separator column;
  • conductivity detector, flow through, low volume, with a non-metallic flow path. Components and tubing that come into contact with the sample solution or eluent shall, as far as possible, be comprising inert materials, e.g. polyetheretherketone (PEEK).

8 Occupational exposure assessment

[4] [5] Refer to ISO 20581, EN 689 and ASTM E1370 for guidance on how to develop an appropriate assessment strategy and for general guidance on measurement strategy.

ISO 21438-2:2024(en)

9 Sampling

9.1 Preliminary considerations

9.1.1 Selection and use of samplers

Select samplers (7.1.1) in accordance with the requirements of the applicable limit value. Size selective samplers shall be designed to collect the appropriate fraction of airborne particles as defined in ISO 7708 and tested in accordance with EN 13205.

If possible, the samplers selected should be manufactured from conducting material, since samplers manufactured from non-conducting material have electrostatic properties that can influence the representative nature of the sampling.

If the samplers selected have an internal filter cassette or cartridge that has to be rinsed during sample preparation, this cassette shall be manufactured from a material that does not react with acids. Use the samplers at their design flow rate and in accordance with the instructions provided by the manufacturer. See Reference [9] for further guidance.

9.1.2 Sampling period

Select a sampling period that is appropriate for the measurement task (see Clause 8) but ensure that it is long enough to enable HCl, HBr or HNO in the air to be determined with acceptable uncertainty at levels

...

Contents

  • Introduction
  • 1 Domaine d’application
  • 2 Références normatives
  • 3 Termes et définitions
  • 3.1 solution de blanc
  • 3.2 solution de blanc d’étalonnage
  • 3.3 solution d’étalonnage
  • 3.4 solution d’extraction
  • 3.5 mise en solution de l’échantillon
  • 3.6 solution d’échantillon
  • 3.7 solution étalon mère
  • 3.8 solution d’essai
  • 3.9 solution étalon de travail
  • 4 Principe
  • 5 Exigence
  • 6 Réactifs
  • 6.6 Solution de carbonate de sodium/bicarbonate de sodium pour la solution d’extraction et
  • 7 Appareillage
  • 7.1 Matériel de prélèvement
  • 7.2 Appareillage de laboratoire
  • 8 Évaluation de l’exposition professionnelle
  • 9 Prélèvement
  • 9.1 Considérations préliminaires
  • 9.2 Préparation du prélèvement
  • 9.3 Point de prélèvement
  • 9.4 Prélèvement des échantillons
  • 9.5 Transport
  • 10 Analyse
  • 10.1 Préparation des solutions d’essai et d’étalonnage et des filtres échantillons
  • 10.2 Analyse instrumentale
  • 10.3 Estimation des limites de détection et de quantification
  • 10.4 Contrôle qualité
  • 10.5 Incertitude de mesure
  • 11 Expression des résultats
  • 12 Performances de la méthode
  • 12.1 Efficacité du prélèvement et conservation des échantillons
  • 12.2 Limites de quantification
  • 12.3 Limites supérieures de l’étendue de mesure
  • 12.4 Biais et fidélité
  • 12.5 Incertitude de la méthode de prélèvement et d’analyse
  • 12.6 Interférences
  • 13 Rapport d’essai
  • 13.1 Procès-verbal de l’essai
  • 13.2 Rapport du laboratoire
  • Annexe A
  • Annexe B
  • Bibliographie

Introduction

L’exposition par inhalation d’acides inorganiques volatils met en danger la santé des travailleurs de nombreux secteurs industriels. Les hygiénistes industriels et autres professionnels de santé publique ont besoin de déterminer l’efficacité des mesures prises pour contrôler l’exposition des travailleurs, ce qui se traduit en général par la réalisation de mesurages de l’air des lieux de travail. Le présent document a été publié afin de mettre à disposition une méthode pour effectuer des mesurages d’exposition valides sur les acides inorganiques volatils utilisés dans l’industrie, tels que l’acide chlorhydrique, l’acide bromhydrique et l’acide nitrique, à l’exception de l’acide fluorhydrique. Le présent document est destiné à être utilisé par:

  • les organismes concernés par l’hygiène et la sécurité au travail;
  • les hygiénistes industriels et autres professionnels de santé publique;
  • les laboratoires d’analyse;
  • les industriels utilisateurs d’acide chlorhydrique, bromhydrique et d’acide nitrique et à leurs salariés, etc.

La mise en œuvre de ces dispositions et l’interprétation des résultats obtenus grâce à l’utilisation du présent document sont confiées à des personnes dotées d’une qualification et d’une expérience appropriées. Le mode opératoire a pour vocation de différencier les acides de leurs sels. Si les deux sont présents dans l’air, les sels particulaires sont piégés sur le préfiltre. Les matières particulaires coéchantillonnées qui sont piégées sur le préfiltre et/ou se déposent sur les parois du dispositif de prélèvement peuvent être analysées, si nécessaire.

Les acides peuvent réagir avec la matière particulaire coéchantillonnée sur le préfiltre, interférant avec la mesure de la concentration d’acide.

Norme internationale ISO 21438-2:2024(fr) Air des lieux de travail — Détermination des acides inorganiques par chromatographie ionique — Partie 2:

Acides volatils, sauf acide fluorhydrique (acide chlorhydrique, acide bromhydrique et acide nitrique)

1 Domaine d’application

Le présent document spécifie une méthode de détermination de la concentration massique moyenne pondérée dans le temps en chlorure d’hydrogène (HCl) gazeux et en brouillards d’acide chlorhydrique, en bromure d’hydrogène (HBr) gazeux et en brouillards d’acide bromhydrique et en vapeurs et brouillards d’acide nitrique (HNO ) dans l’air des lieux de travail, par prélèvement sur un filtre en fibres de quartz alcalin

et analyse par chromatographie ionique.

En cas de prélèvement de brouillard, cette méthode est applicable au prélèvement individuel de la fraction inhalable des particules en suspension dans l’air, comme défini dans l’ISO 7708, ainsi qu’au prélèvement à point fixe.

2 Références normatives

Les documents suivants sont cités dans le texte de sorte qu’ils constituent, pour tout ou partie de leur contenu, des exigences du présent document. Pour les références datées, seule l’édition citée s’applique. Pour les références non datées, la dernière édition du document de référence s'applique (y compris les éventuels amendements).

ISO 1042, Verrerie de laboratoire — Fioles jaugées à un trait ISO 3585, Verre borosilicaté 3.3 — Propriétés ISO 3696, Eau pour laboratoire à usage analytique — Spécification et méthodes d'essai ISO 7708, Qualité de l'air — Définitions des fractions de taille des particules pour l'échantillonnage lié aux problèmes de santé ISO 8655-1, Appareils volumétriques à piston — Partie 1: Définitions, exigences générales et recommandations pour l'utilisateur ISO 8655-2, Appareils volumétriques à piston — Partie 2: Pipettes ISO 8655-6, Appareils volumétriques à piston — Partie 6: Mode opératoire de mesure gravimétrique de référence pour la détermination de volumes ISO 18158, Qualité de l'air — Terminologie ISO 20581, Air des lieux de travail — Exigences générales concernant les performances des procédures de mesure des agents chimiques ISO 21832:2018, Air des lieux de travail — Métaux et métalloïdes dans les particules en suspension dans l'air — Exigences relatives à l'évaluation des procédures de mesure EN 13205, Exposition sur les lieux de travail — Évaluation des performances des dispositifs de prélèvement pour le mesurage des concentrations de particules en suspension dans l’air

ISO 21438-2:2024(fr)

3 Termes et définitions

Pour les besoins du présent document, les termes et les définitions de l’ISO 18158, ainsi que les suivants s’appliquent.

L’ISO et l’IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en normalisation, consultables aux adresses suivantes:

  • ISO Online browsing platform: disponible à l’adresse https:// www .iso .org/ obp
  • IEC Electropedia: disponible à l’adresse https:// www .electropedia .org/

3.1 solution de blanc

solution préparée à partir d’un blanc de réactifs, d’un blanc de laboratoire ou d’un blanc de terrain en utilisant le même mode opératoire que pour la mise en solution de l’échantillon (3.5)

3.2 solution de blanc d’étalonnage

solution d’étalonnage (3.3) préparée sans addition d’aucune solution étalon de travail (3.9) Note 1 à l'article: La concentration d’ions chlorures, de bromures et de nitrates dans la solution de blanc d’étalonnage est réputée nulle.

3.3 solution d’étalonnage

solution obtenue par dilution de la solution étalon de travail (3.9), contenant du chlorure, du bromure et du nitrate à des concentrations adaptées à l’étalonnage de l’instrument d’analyse

3.4 solution d’extraction

solvant ou solution utilisés pour solubiliser l’analyte ou les analytes étudiés

3.5 mise en solution de l’échantillon

processus permettant d’obtenir une solution contenant des ions chlorure, bromure et nitrate à partir d’un échantillon, impliquant ou non la mise en solution complète de l’échantillon

3.6 solution d’échantillon

solution préparée, à partir d’un échantillon, au moyen du processus de mise en solution d’échantillon (3.5) Note 1 à l'article: Une solution d’échantillon peut nécessiter plusieurs opérations, par exemple, une dilution, afin de produire une solution d’essai (3.8) prête pour l’analyse.

3.7 solution étalon mère

solution, utilisée dans la préparation des solutions d’étalonnage (3.3), contenant des ions chlorure, bromure et/ou nitrate à une concentration certifiée dont la traçabilité aux étalons nationaux est garantie

3.8 solution d’essai

solution de blanc (3.1) ou solution d’échantillon (3.6) ayant été soumise à toutes les opérations nécessaires à sa préparation en vue de l’analyse, par exemple une dilution ou une filtration Note 1 à l'article: Si ces solutions ne sont pas soumises à d’autres traitements avant analyse, la solution d’essai à blanc est la solution de blanc, et la solution d’échantillon est la solution d’essai.

ISO 21438-2:2024(fr)

3.9 solution étalon de travail

solution préparée par dilution d’une ou de plusieurs solutions étalons mères (3.7) et contenant des ions chlorure, bromure et nitrate à des concentrations plus adaptées à la préparation des solutions d’étalonnage (3.3) que les concentrations de chlorures, bromures et nitrates de la ou des solutions étalons mères

4 Principe

Un volume défini d’air est aspiré à travers un dispositif de prélèvement de la fraction inhalable contenant un préfiltre et un filtre de prélèvement en fibres de quartz alcalin, pour recueillir HCl, HBr et HNO . Les acides

sont collectés sur le filtre de prélèvement, tandis que les sels particulaires des acides sont piégés sur le préfiltre.

Les acides recueillis sur le filtre de prélèvement sont extraits avec de l’eau ou de l’éluant (voir 10.1.2), sans chauffer, pour dissoudre les analytes étudiés.

Des aliquotes de la solution d’échantillon sont traitées par chromatographie ionique pour séparer les ions chlorures, nitrates ou bromures extraits des autres anions. À la suite de cette séparation, les anions sont mesurés à l’aide d’un détecteur conductimétrique ou UV/visible. Les résultats d’analyse sont obtenus en reportant le signal mesuré en fonction de la concentration. Ils peuvent être utilisés pour évaluer l’exposition professionnelle à HCl, HBr et HNO dans l’air.

5 Exigence

La procédure de mesure doit satisfaire aux exigences de performance des procédures de mesure des agents chimiques dans l’air des lieux de travail énoncées dans l’ISO 20581.

6 Réactifs

Utiliser uniquement des réactifs de qualité analytique reconnue et de l’eau telle que spécifiée en 6.1. Il est recommandé de vérifier les valeurs de blanc de tous les produits chimiques avant utilisation. NOTE Les chlorures et les nitrates sont omniprésents dans l’environnement et leur présence dans les réactifs peut se traduire par des valeurs de blanc élevées. Il est par conséquent recommandé de vérifier les valeurs de blanc de tous les produits chimiques avant utilisation.

6.1 Eau, d’un système de purification délivrant de l’eau ultrapure de qualité 1, conformément aux exigences de l’ISO 3696.

NOTE Les systèmes de purification actuels du marché fournissent de l’eau de qualité 1 affichant un niveau de qualité supérieur à celui spécifié dans l’ISO 3696 (par exemple une résistivité supérieure à 18 MΩ·cm). 6.2 Carbonate de sodium (Na CO ), anhydre, d’une fraction massique supérieure à 99,9 %. 2 3 6.3 Solution de carbonate de sodium, 1 mol/l, pour l’imprégnation des filtres en fibres de quartz de 37 mm de diamètre.

Dissoudre 10,6 g de Na CO (6.2) dans de l’eau. Transférer quantitativement la solution dans une fiole jaugée 2 3 à un trait de 100 ml, diluer jusqu’au trait avec de l’eau, boucher et mélanger soigneusement. 6.4 Bicarbonate de sodium (NaHCO ), anhydre, d’une fraction massique supérieure à 99,9 %.

ISO 21438-2:2024(fr) 6.5 Solution mère de carbonate de sodium/bicarbonate de sodium pour la solution d’extraction et l’éluant.

Créer une solution mère pour la solution d’extraction et l’éluant. La solution mère doit être adaptée à l’application prévue.

6.6 Solution de carbonate de sodium/bicarbonate de sodium pour la solution d’extraction et

l’éluant.

La concentration de la solution d’extraction et celle de l’éluant sont identiques en général, mais il est possible de les modifier conformément au mode opératoire du laboratoire. NOTE Une solution alcaline (hydroxyde de potassium ou hydroxyde de sodium) peut être utilisée à la place de la solution tampon selon les modifications apportées à la méthode, mais la solution obtenue nécessitera d’être ajustée avant l’analyse.

6.7 Solutions étalons de chlorure, de bromure et de nitrate.

6.7.1 Solutions mères de chlorure, de bromure et de nitrate.

Utiliser une solution étalon commerciale présentant une concentration certifiée (1 000 mg/l par exemple) et garantissant une traçabilité aux étalons nationaux. Respecter la date d’expiration fixée par le fabricant ou la durée de conservation recommandée. Si nécessaire, diluer la solution étalon (par exemple de 1 000 mg/l à 100 mg/l) afin de préparer la solution de travail de référence. 6.7.2 Solutions d’étalonnage de chlorure, de bromure et de nitrate. Pipeter des volumes appropriés de la solution mère ou solution de travail de référence pour obtenir la droite d’étalonnage. Le domaine d’étalonnage doit être conforme à l’étendue de mesure calculée dans l’ISO 21832:2018, 5.2.1, et à la limite de quantification (LQ) présentée dans l’ISO 21832:2018, 8.1.2. Un étalonnage à plusieurs points (nombre de points à déterminer selon le système qualité du laboratoire) doit être mis en œuvre au sein du domaine de linéarité de la méthode d’analyse. 6.8 Étalons de référence de chlorure, de bromure et de nitrate. Utiliser un matériau de référence certifié (MRC) tel que décrit en 10.4.3 présentant une concentration certifiée, par exemple 200 mg/l de chlorure, 400 mg/l de bromure et 400 mg/l de nitrate, traçable par rapport aux étalons nationaux. Respecter la date d’expiration fixée par le fabricant ou la durée de conservation recommandée.

6.9 Solution de travail de référence de chlorure, de bromure et de nitrate. Il convient que la solution de travail de référence se trouve au milieu du domaine d’étalonnage. Pipeter un volume approprié d’étalon de référence (6.8) afin de créer une solution de travail de référence avec l’éluant (6.6). Préparer cette solution extemporanément à chaque étalonnage. Si nécessaire, préparer une solution de travail de référence distincte pour le chlorure, le bromure et le nitrate.

7 Appareillage

7.1 Matériel de prélèvement

7.1.1 Dispositifs de prélèvement, conçus pour recueillir la fraction inhalable des particules en suspension dans l’air, conformes à l’EN 13205, adaptés au montage d’un préfiltre et d’un filtre de prélèvement séparés par un intercalaire, fabriqués dans un matériau ne réagissant pas avec les acides. NOTE 1 Si les dispositifs de prélèvement contiennent une cassette porte-filtre interne, celle-ci doit également être fabriquée dans un matériau ne réagissant pas avec les acides.

ISO 21438-2:2024(fr) NOTE 2 Parmi les matériaux ne réagissant pas avec les acides, dans lesquels les dispositifs de prélèvement et les cassettes porte-filtre interne peuvent être fabriqués, figurent le polytétrafluoroéthylène (PTFE) et autres polymères fluorés, le polychlorure de vinyle (PVC), le polyéthylène, le polypropylène et le polycarbonate. [9] NOTE 3 La CEN/TR 15230 donne des exemples de dispositifs de prélèvement inhalables susceptibles de satisfaire aux exigences de l’EN 13205 disponibles sur le marché jusqu’en 2004, y compris la liste des rapports publiés sur leurs performances.

7.1.2 Filtres, d’un diamètre adapté à une utilisation avec les dispositifs de prélèvement (7.1.1). Le chlorure d’hydrogène (HCl) gazeux et les brouillards d’acide chlorhydrique, le bromure d’hydrogène (Hbr) gazeux et les brouillards d’acide bromhydrique, ainsi que les vapeurs et brouillards d’acide nitrique (HNO )

sont des acides forts. Par conséquent, il est primordial de choisir correctement le filtre utilisé en vue du prélèvement d’échantillons. De plus, certains filtres, tels que les filtres en fibres de verre, peuvent contenir des métaux, comme du baryum, qui réagissent avec les acides pour produire des sels insolubles. Le chlorure, le bromure et le nitrate sont omniprésents dans l’environnement et leur présence dans les matériaux des filtres peut se traduire par des valeurs de blanc élevées. Il est par conséquent essentiel de vérifier les valeurs de blanc de tous les lots de filtres utilisés. 7.1.2.1 Préfiltres, d’un diamètre adapté à une utilisation avec les dispositifs de prélèvement (7.1.1), d’une efficacité de prélèvement ≥ 99 % pour les particules d’un diamètre de diffusion de 0,3 µm, fabriqués dans un matériau qui ne réagit pas avec HCl, HBr ou HNO , adaptés à une utilisation en tant que préfiltres afin

de retirer les sels particulaires interférents et compatibles avec la méthode d’analyse et de préparation des échantillons.

Se reporter à l’Article B.1 pour obtenir des recommandations relatives aux matériaux appropriés pour la fabrication des préfiltres.

7.1.2.2 Filtres de prélèvement, en fibres de quartz, imprégnés d’une solution de carbonate de sodium, adaptés à une utilisation en tant que filtres de prélèvement pour les acides inorganiques volatils, par exemple filtres de 25 mm de diamètre imprégnés de 200 µl de solution de carbonate de sodium 2,5 mol/l ou filtres de 37 mm de diamètre imprégnés de 500 µl de solution de carbonate de sodium 1 mol/l (63) (voir les Références [10] et [11]).

Se reporter à l’Article B.2 pour obtenir des recommandations relatives aux matériaux appropriés pour la fabrication des filtres de prélèvement.

7.1.3 Intercalaires, d’un diamètre adapté à une utilisation avec des dispositifs de prélèvement (7.1.1), destinés à séparer les préfiltres (7.1.2.1) et les filtres de prélèvement (7.1.2.2), fabriqués dans un matériau inerte qui ne réagit pas avec les acides ni ne les adsorbe, par exemple, manchons en polypropylène ou écrans revêtus de PTFE.

[1] 7.1.4 Pompes de prélèvement, il convient d’utiliser des modèles conformes à l’ISO 13137 . [1] Si la pompe de prélèvement est utilisée en dehors du domaine des conditions spécifiées dans l’ISO 13137, il convient de prendre des mesures appropriées pour s’assurer que les exigences de performance sont satisfaites. Par exemple, à des températures inférieures à zéro, il peut se révéler nécessaire de maintenir la pompe au chaud.

7.1.5 Débitmètre, portable, d’une précision suffisante pour mesurer le débit volumétrique à ±5 %. L’étalonnage du débitmètre doit être vérifié par rapport à un étalon primaire, c’est-à-dire un débitmètre dont l’exactitude est traçable jusqu’aux étalons nationaux. S’il y a lieu (voir 9.1.3), enregistrer la température et la pression atmosphériques auxquelles l’étalonnage du débitmètre a été vérifié. Il est recommandé que le débitmètre utilisé puisse mesurer le débit volumétrique à ±2 % ou mieux.

ISO 21438-2:2024(fr) 7.1.6 Équipement auxiliaire.

  • Tuyau souple, par exemple en silicone, d’un diamètre extérieur de 10 mm et d’un diamètre intérieur de 6 mm pour un raccordement étanche entre les dispositifs de prélèvement et les pompes de prélèvement sans phénomène de compression découlant de la différence de pression entre l’atmosphère ambiante et la dépression créée dans le circuit au débit.
  • Ceintures ou harnais, auxquels les pompes de prélèvement peuvent se fixer facilement en vue d’un prélèvement sur opérateur.
  • Pinces, fabriquées ou recouvertes de PTFE, pour manipuler les filtres.
  • Cassettes de transport de filtres, ou dispositif analogue, si nécessaire (voir 9.5.1), permettant de transporter les échantillons jusqu’au laboratoire.
  • Thermomètre, d’une plage de 0 °C à 50 °C, gradué en échelons de 1 °C ou moins, pour mesurer la température atmosphérique. Dans le cas d’applications à des températures négatives, la plage du thermomètre doit s’étendre à la plage de mesure souhaitée.
  • Baromètre, adapté au mesurage de la pression atmosphérique.

7.2 Appareillage de laboratoire

ATTENTION — Les chlorures, les nitrates et, dans une moindre mesure, les bromures sont omniprésents dans l’environnement et la présence de chlorures, en particulier, peut se traduire par des niveaux de blanc élevés. Vérifier l’ensemble du matériel de laboratoire à usage unique avant utilisation pour déceler toute contamination aux chlorures, nitrates et bromures, et nettoyer soigneusement tout le matériel de laboratoire réutilisable.

7.2.1 Gants à usage unique, imperméables, pour empêcher toute possibilité de contamination par

les mains et les protéger du contact avec des substances toxiques et corrosives. Des gants en PVC sont adéquats.

7.2.2 Verrerie, en verre borosilicaté 3,3, conforme aux exigences énoncées dans l’ISO 3585, nettoyée à l’eau (6.1) avant utilisation.

La verrerie peut également être lavée à l’aide d’un lave-verrerie de laboratoire en utilisant un détergent de laboratoire sans phosphate adapté, puis être rincée soigneusement à l’eau (6.1). 7.2.3 Fioles jaugées à un trait, d’une capacité allant jusqu’à 2 l, conformes aux exigences de l’ISO 1042. 7.2.4 Verrerie de laboratoire en plastique.

  • Récipients en polyéthylène à bouchons à vis, adaptés à l’extraction des filtres de prélèvement.
  • Béchers d’une capacité appropriée.
  • Filtres à usage unique, en PTFE, d’une porosité de 0,45 µm, destinés à être utilisés en chromatographie ionique.
  • Seringues jetables d’une capacité appropriée, équipées d’aiguilles adaptées.
  • Flacons de passeur automatique, d’une capacité appropriée.

7.2.5 Appareils volumétriques à piston, d’une capacité comprise entre 50 µl et 10 ml, conformes aux exigences de l’ISO 8655-1, et soumis à essai conformément aux exigences de l’ISO 8655-6; pipettes, conformes aux exigences de l’ISO 8655-2, comme alternative aux pipettes à un trait pour la préparation de solutions étalons et de solutions d’étalonnage, ainsi que pour la dilution des échantillons.

...