This document specifies performance requirements and test methods under prescribed laboratory conditions for the evaluation of pumped samplers used in conjunction with an air sampling pump and of procedures using these samplers for the determination of gases and vapours in workplace atmospheres. This document addresses requirements for method developers and/or manufacturers. NOTE 1 For the purposes of this document, a manufacturer can be any commercial or non-commercial entity. NOTE 2 For the sa...view more

    • sale 15% off
    • Standard
      42 pages
      French language
    • sale 15% off
    • Draft
      42 pages
      French language
    • sale 15% off
    • Standard
      37 pages
      English language
    • sale 15% off
    • Draft
      37 pages
      English language

This document specifies a method for collecting samples of airborne particulate matter for subsequent determination of metals and metalloids using inductively coupled plasma — atomic emission spectrometry (ICP-AES). Samples obtained using the method described herein can also be subsequently analysed for elemental composition by other instrumental methods, such as atomic absorption spectrometry (AAS) or inductively coupled plasma mass spectrometry (ICP-MS).
The method is not applicable to the sa...
view more

    • sale 15% off
    • Standard
      17 pages
      English language
    • sale 10% off
    • Standard
      22 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard
      22 pages
      English language
    • e-Library read for
      1 day
    • sale 15% off
    • Standard
      18 pages
      French language

This document specifies a number of suitable methods for preparing test solutions from samples of airborne particulate matter collected using the method specified in ISO 15202‑1, for subsequent determination of metals and metalloids by ICP‑AES using the method specified in ISO 15202‑3. It contains information about the applicability of the methods with respect to the measurement of metals and metalloids for which limit values have been set. The methods can also be used in the measurement of some...view more

    • sale 10% off
    • Standard
      54 pages
      English language
    • e-Library read for
      1 day
    • sale 15% off
    • Standard
      55 pages
      French language
    • sale 10% off
    • Standard
      54 pages
      English language
    • e-Library read for
      1 day
    • sale 15% off
    • Standard
      49 pages
      English language

This document specifies a method for collecting samples of airborne particulate matter for subsequent determination of metals and metalloids using inductively coupled plasma — atomic emission spectrometry (ICP-AES). Samples obtained using the method described herein can also be subsequently analysed for elemental composition by other instrumental methods, such as atomic absorption spectrometry (AAS) or inductively coupled plasma mass spectrometry (ICP-MS). The method is not applicable to the sam...view more

    • sale 15% off
    • Standard
      17 pages
      English language
    • sale 10% off
    • Standard
      22 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard
      22 pages
      English language
    • e-Library read for
      1 day
    • sale 15% off
    • Standard
      18 pages
      French language

This document specifies a number of suitable methods for preparing test solutions from samples of airborne particulate matter collected using the method specified in ISO 15202‑1, for subsequent determination of metals and metalloids by ICP‑AES using the method specified in ISO 15202‑3. It contains information about the applicability of the methods with respect to the measurement of metals and metalloids for which limit values have been set. The methods can also be used in the measurement of some...view more

    • sale 10% off
    • Standard
      54 pages
      English language
    • e-Library read for
      1 day
    • sale 15% off
    • Standard
      55 pages
      French language
    • sale 10% off
    • Standard
      54 pages
      English language
    • e-Library read for
      1 day
    • sale 15% off
    • Standard
      49 pages
      English language

This document specifies performance requirements and test methods for the evaluation of procedures for measuring metals and metalloids in airborne particles sampled onto a suitable collection substrate.
This document specifies a method for estimating the uncertainties associated with random and systematic errors and combining them to calculate the expanded uncertainty of the measuring procedure as a whole, as prescribed in ISO 20581.
This document is applicable to measuring procedures in which...
view more

    • sale 10% off
    • Standard
      45 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      42 pages
      English language
    • e-Library read for
      1 day

This document specifies performance requirements and test methods for the evaluation of procedures for measuring metals and metalloids in airborne particles sampled onto a suitable collection substrate.
This document specifies a method for estimating the uncertainties associated with random and systematic errors and combining them to calculate the expanded uncertainty of the measuring procedure as a whole, as prescribed in ISO 20581.
This document is applicable to measuring procedures in which...
view more

    • sale 10% off
    • Standard
      45 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      42 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies general requirements for the measurement of microorganisms and microbial compounds. This European Standard provides also guidelines for the assessment of workplace exposure to airborne micro-organisms including the determination of total number and culturable number of micro-organisms and microbial compounds in the workplace atmosphere.

    • sale 10% off
    • Standard
      42 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      42 pages
      English language
    • e-Library read for
      1 day

This document specifies general requirements for the measurement of microorganisms and microbial compounds.
This document provides also guidelines for the assessment of workplace exposure to airborne microorganisms including the determination of total number and culturable number of microorganisms and microbial compounds in the workplace atmosphere.
This document does not apply to the measurement of viruses.

    • sale 10% off
    • Standard
      42 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      42 pages
      English language
    • e-Library read for
      1 day

This document is a standard for the analysis by Fourier-Transform Infrared (FTIR) of respirable
crystalline silica (RCS) in samples of air collected on collection substrates (i.e. filters or foams). Three
analytical approaches are described for whom the dust from the sample collection substrate is
a) analysed directly on sampled filter,
b) recovered, treated and deposited onto another filter for analysis, or
c) recovered, treated and pressed into a potassium bromide (KBr) pellet for analysi...
view more

    • sale 15% off
    • Standard
      30 pages
      English language
    • sale 10% off
    • Standard
      36 pages
      English language
    • e-Library read for
      1 day

This document specifies a method for the sampling and analysis of airborne organic isocyanates in
workplace air.
This document is applicable to a wide range of organic compounds containing isocyanate groups,
including monofunctional isocyanates (e.g. phenyl isocyanate), diisocyanate monomers [e.g.
1,6-hexamethylene diisocyanate (HDI), toluene diisocyanate (TDI), 4,4′-diphenylmethane diisocyanate
(MDI), and isophorone diisocyanate (IPDI)], prepolymers (e.g. the biuret and isocyanurate of HDI...
view more

    • sale 15% off
    • Standard
      30 pages
      English language
    • sale 10% off
    • Standard
      36 pages
      English language
    • e-Library read for
      1 day

ISO 16639:2017 provides best practices and performance-based criteria for the use of air sampling devices and systems, including retrospective samplers and continuous air monitors. Specifically, this document covers air sampling program objectives, design of air sampling and monitoring programs to meet program objectives, methods for air sampling and monitoring in the workplace, and quality assurance to ensure system performance toward protecting workers against unnecessary inhalation exposures....view more

    • sale 10% off
    • Standard
      41 pages
      English language
    • e-Library read for
      1 day

This European Standard provides the methodology for measuring and characterizing the dustiness of a bulk material that contains or releases nano-objects or submicrometer particles. In addition, it specifies the environmental conditions, the sample handling procedure and the method of calculating and presenting the results. Guidance is given on the choice of method to be used.
The methodology described in this European Standard enables
a)   the quantification of dustiness in terms of health-relat...
view more

    • sale 10% off
    • Standard
      31 pages
      English language
    • e-Library read for
      1 day

This European Standard provides the methodology for measuring the dustiness of bulk materials that contain or release nano-objects or submicrometer particles, under standard and reproducible conditions and specifies for that purpose the rotating drum method.
In addition, this European Standard specifies the selection of instruments and devices and the procedures for calculating and presenting the results. It also gives guidelines on the evaluation and reporting of the data.
The methodology des...
view more

    • sale 10% off
    • Standard
      24 pages
      English language
    • e-Library read for
      1 day

This European Standard provides the methodology for measuring and characterizing the dustiness of bulk materials that contain or release nano-objects or submicrometer particles, under standard and reproducible conditions and specifies for that purpose the vortex shaker method.
In addition, this European Standard specifies the selection of instruments and devices and the procedures for calculating and presenting the results. It also gives guidelines on the evaluation and reporting of the data.
...
view more

    • sale 10% off
    • Standard
      37 pages
      English language
    • e-Library read for
      1 day

This European Standard provides the methodology for measuring the dustiness of bulk materials that contain or release nano-objects or submicrometer particles, under standard and reproducible conditions and specifies for that purpose the continuous drop method.
In addition, this European Standard specifies the selection of instruments and devices and the procedures for calculating and presenting the results. It also gives guidelines on the evaluation and reporting of the data.
The methodology d...
view more

    • sale 10% off
    • Standard
      24 pages
      English language
    • e-Library read for
      1 day

This European Standard provides the methodology for measuring and characterizing the dustiness of bulk materials that contain or release nano-objects or submicrometer particles, under standard and reproducible conditions and specifies for that purpose the small rotating drum method.
In addition, this European Standard specifies the selection of instruments and devices and the procedures for calculating and presenting the results. It also gives guidelines on the evaluation and reporting of the d...
view more

    • sale 10% off
    • Standard
      27 pages
      English language
    • e-Library read for
      1 day

ISO 16639:2017 provides best practices and performance-based criteria for the use of air sampling devices and systems, including retrospective samplers and continuous air monitors. Specifically, this document covers air sampling program objectives, design of air sampling and monitoring programs to meet program objectives, methods for air sampling and monitoring in the workplace, and quality assurance to ensure system performance toward protecting workers against unnecessary inhalation exposures....view more

    • sale 10% off
    • Standard
      41 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies a strategy to perform representative measurements of exposure by
inhalation to chemical agents in order to demonstrate the compliance with occupational exposure limit
values (OELVs).
This European Standard is not applicable to OELVs with reference periods less than 15 min.

    • sale 10% off