This document specifies a method for the sampling of NO2 in ambient air using diffusive sampling followed by extraction and analysis by colourimetry or ion chromatography (IC). It can be used for the NO2 measurement in a concentration range of approximately 3 µg/m3 to 130 µg/m3 [12]. A sample is typically collected for a period of 1 to 4 weeks [14], with exposure periods depending on the design of the samplers and the concentration levels of NO2.
Several sorbents can be used for trapping NO2 in ambient air using a diffusive sampler [15]. This document specifies the application of triethanolamine as the reagent.
This document describes the application of a tube-type sampler (with either a cylindrical or a slightly conical tube), a badge-type sampler and a radial-type sampler.
The relative expanded uncertainty of NO2 measurements performed using these tube-type diffusive samplers can potentially be lower than 25 % for individual measurements. When aggregating results to form annual average values, the relative expanded uncertainty can be further reduced to levels below 15 % due to the reduction of random effects on uncertainty [9].
NOTE   NO2 passive samplers are also employed to measure NOx with the addition of an oxidant to convert ambient NO into NO2. A second NO2 sampler is also deployed without the oxidant and the concentration of NO is determined from the difference of the two samplers [16].

  • Standard
    54 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method for the sampling of NO2 in ambient air using diffusive sampling followed by extraction and analysis by colourimetry or ion chromatography (IC). It can be used for the NO2 measurement in a concentration range of approximately 3 µg/m3 to 130 µg/m3 [12]. A sample is typically collected for a period of 1 to 4 weeks [14], with exposure periods depending on the design of the samplers and the concentration levels of NO2.
Several sorbents can be used for trapping NO2 in ambient air using a diffusive sampler [15]. This document specifies the application of triethanolamine as the reagent.
This document describes the application of a tube-type sampler (with either a cylindrical or a slightly conical tube), a badge-type sampler and a radial-type sampler.
The relative expanded uncertainty of NO2 measurements performed using these tube-type diffusive samplers can potentially be lower than 25 % for individual measurements. When aggregating results to form annual average values, the relative expanded uncertainty can be further reduced to levels below 15 % due to the reduction of random effects on uncertainty [9].
NOTE   NO2 passive samplers are also employed to measure NOx with the addition of an oxidant to convert ambient NO into NO2. A second NO2 sampler is also deployed without the oxidant and the concentration of NO is determined from the difference of the two samplers [16].

  • Standard
    54 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a continuous measurement method for the determination of the concentration of sulfur dioxide present in ambient air based on the ultraviolet fluorescence measuring principle. This document describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate ultraviolet fluorescence analyser by means of type testing. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality assurance for use.
The method is applicable to the determination of the mass concentration of sulphur dioxide present in ambient air up to 1000 µg/m3. This concentration range represents the certification range for sulfur dioxide for type testing.
NOTE 1   It is possible to use other ranges depending on the levels present in ambient air.
NOTE 2   When this document is used for purposes other than for measurements required by Directive 2008/50/EC, the ranges and uncertainty requirements possibly do not apply.
The method covers the determination of ambient air concentrations of sulfur dioxide in locations classified as rural areas, urban-background areas, and for sampling influenced by traffic or industrial sources.
The results are expressed in µg/m3 (at 20 °C and 101,3 kPa).
NOTE 3   1 000 µg/m3 of SO2 corresponds to 376 nmol/mol of SO2.
This document contains information for different groups of users.
Clause 5 to Clause 7 and Annex C and Annex D contain general information about the principles of sulfur dioxide measurement by ultraviolet fluorescence analyser and sampling equipment.
Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type testing of sulfur dioxide analysers. These sections contain information about:
—   type testing conditions, test procedures and test requirements;
—   analyser performance requirements;
—   evaluation of the type testing results;
—   evaluation of the uncertainty of the measurement results of the sulfur dioxide analyser based on the type testing results.
Clause 9 to Clause 11 and Annex F and Annex G are directed towards monitoring networks performing the practical measurements of sulfur dioxide in ambient air. These sections contain information about:
—   initial installation of the analyser in the monitoring network and acceptance testing;
—   ongoing quality assurance/quality control;
—   calculation and reporting of measurement results;
—   evaluation of the uncertainty of the measurement results under practical monitoring conditions.
This document represents an evolution of earlier editions (EN 14212:2005 and EN 14212:2012). It is advisable that when equipment is procured it complies fully with this document.
NOTE 4   Type testing performed prior to the publication of this document for the purpose of demonstrating equivalence are still valid.
NOTE 5   Analysers type tested prior to the publication of this document remain valid for use for regulated monitoring purposes.

  • Standard
    124 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a continuous measurement method for the determination of the concentration of carbon monoxide present in ambient air based on the non-dispersive infrared spectroscopic measuring principle.
This standard describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate non-dispersive infrared spectroscopic analyser by means of type approval tests. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality assurance for use.
The method is applicable to the determination of the mass concentration of carbon monoxide present in ambient air up to 100 mg/m3 carbon monoxide. This concentration range represents the certification range for the type approval test.
NOTE 1 Other ranges may be used depending on the levels present in ambient air.
NOTE 2 When the standard is used for other purposes than for measurements required by Directive 2008/50/EC, the ranges and uncertainty requirements may not apply.
The method covers the determination of ambient air concentrations of carbon monoxide in zones classified as rural areas, urban-background areas and traffic-orientated locations and locations influenced by industrial sources.
The results are expressed in mg/m3 (at 20 °C and 101,3 kPa).
NOTE 3 100 mg/m3 of CO corresponds to 86 μmol/mol of CO.
This standard contains information for different groups of users.
Clauses 5 to 7 and Annexes B, C and D contain general information about the principles of carbon monoxide measurement by non-dispersive infrared spectroscopic analyser and sampling equipment.
Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type-approval testing of carbon monoxide analysers. These sections contain information about:
− type-approval test conditions, test procedures and test requirements;
− analyser performance requirements;
− evaluation of the type-approval test results;
− evaluation of the uncertainty of the measurement results of the carbon monoxide analyser based on the type approval test results.
Clauses 9 to 11 and Annex F are directed towards monitoring networks performing the practical measurements of carbon monoxide in ambient air. These sections contain information about:
− initial installation of the analyser in the monitoring network and acceptance testing;
− ongoing quality assurance/quality control;
− calculation and reporting of measurement results;
− evaluation of the uncertainty of measurement results under practical monitoring conditions.

  • Standard
    105 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a continuous measurement method for the determination of the concentrations of ozone present in ambient air based on the ultraviolet photometric measuring principle. This standard describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate ultraviolet photometric analyser by means of type approval tests. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality assurance for use.
The method is applicable to the determination of the concentration of ozone present in ambient air up to 500 μg/m3.
This concentration range represents the certification range for ozone for the type approval test.
NOTE 1 Other ranges may be used for measurement systems applied at rural locations monitoring ecosystems.
NOTE 2 When the standard is used for other purposes than Directive 2008/50/EC, the ranges and uncertainty requirements may not apply.
The method covers the determination of ambient air concentrations of ozone in zones classified as rural areas, urban and urban-background areas.
The results are expressed in μg/m3 (at 20 °C and 101,3 kPa).
NOTE 3 500 μg/m3 of O3 corresponds to 250 nmol/mol of O3 at 20 °C and 101,3 kPa.
This standard contains information for different groups of users.
Clauses 5 to 7 and Annexes B and C contain general information about the principles of ozone measurement by ultraviolet photometric analyser and sampling equipment.
Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type-approval testing of ozone analysers. These sections contain information about:
− type-approval test conditions, test procedures and test requirements;
− analyser performance requirements;
− evaluation of the type-approval test results;
− evaluation of the uncertainty of the measurement results of the ozone analyser based on the type-approval test results.
Clauses 9 to 11 and Annexes F and G are directed towards monitoring networks performing the practical
measurements of ozone in ambient air. These sections contain information about:
− initial installation of the analyser in the monitoring network and acceptance testing;
− ongoing quality assurance/quality control;
− calculation and reporting of measurement results;
− evaluation of the uncertainty of measurement results under practical monitoring conditions.

  • Standard
    114 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a continuous measurement method for the determination of the concentrations of nitrogen dioxide and nitrogen monoxide present in ambient air based on the chemiluminescence measuring principle. This document describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate chemiluminescence analyser by means of type testing. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality assurance for use.
The method is applicable to the determination of the concentration of nitrogen dioxide present in ambient air up to 500 µg/m3. This concentration range represents the certification range for nitrogen dioxide for type testing.
The method is applicable to the determination of the concentration of nitrogen monoxide present in ambient air up to 1 200 µg/m3. This concentration range represents the certification range for nitrogen monoxide for the type testing.
NOTE 1   It is possible to use other ranges depending on the levels present in ambient air.
NOTE 2   When this document is used for purposes other than for measurements required by Directive2008/50/EC, the ranges and uncertainty requirements possibly do not apply.
The method covers the determination of ambient air concentrations of nitrogen dioxide and nitrogen monoxide in zones classified as rural areas, urban-background areas, traffic-orientated locations and locations influenced by industrial sources.
The results are expressed in µg/m3 (at 20 °C and 101,3 kPa).
NOTE 3   500 µg/m3 of nitrogen dioxide corresponds to 261 nmol/mol of nitrogen dioxide at 20 °C and 101,3 kPa. 1 200 µg/m3 of nitrogen monoxide corresponds to 962 nmol/mol of nitrogen monoxide at 20 °C and 101,3 kPa.
This document contains information for different groups of users.
Clause 5 to Clause 7 and Annex B and Annex C contain general information about the principles of NOx measurement by chemiluminescence analyser and sampling equipment.
Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type testing of NOx analysers. These sections contain information about:
—   type testing conditions, test procedures and test requirements;
—   analyser performance requirements;
—   evaluation of the type testing results;
—   evaluation of the uncertainty of the measurement results of the NOx analyser based on the type testing results.
Clause 9 to Clause 11 and Annex F and Annex G are directed towards monitoring networks performing the practical measurements of NOx in ambient air. These sections contain information about:
—   initial installation of the analyser in the monitoring network and acceptance testing;
—   ongoing quality assurance/quality control;
—   calculation and reporting of measurement results;
—   evaluation of the uncertainty of measurement results under practical monitoring conditions.
This document represents an evolution of earlier editions (EN 14211:2005 and EN 14211:2012). It is advisable that when equipment is procured it complies fully with this document.
NOTE 4   Type testing performed prior to the publication of this document for the purpose of demonstrating equivalence are still valid.
NOTE 5   Analysers type tested prior to the publication of this document remain valid for use for regulated monitoring purposes.

  • Standard
    120 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a continuous measurement method for the determination of the concentrations of ozone present in ambient air based on the ultraviolet photometric measuring principle. This standard describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate ultraviolet photometric analyser by means of type approval tests. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality assurance for use.
The method is applicable to the determination of the concentration of ozone present in ambient air up to 500 μg/m3.
This concentration range represents the certification range for ozone for the type approval test.
NOTE 1 Other ranges may be used for measurement systems applied at rural locations monitoring ecosystems.
NOTE 2 When the standard is used for other purposes than Directive 2008/50/EC, the ranges and uncertainty requirements may not apply.
The method covers the determination of ambient air concentrations of ozone in zones classified as rural areas, urban and urban-background areas.
The results are expressed in μg/m3 (at 20 °C and 101,3 kPa).
NOTE 3 500 μg/m3 of O3 corresponds to 250 nmol/mol of O3 at 20 °C and 101,3 kPa.
This standard contains information for different groups of users.
Clauses 5 to 7 and Annexes B and C contain general information about the principles of ozone measurement by ultraviolet photometric analyser and sampling equipment.
Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type-approval testing of ozone analysers. These sections contain information about:
− type-approval test conditions, test procedures and test requirements;
− analyser performance requirements;
− evaluation of the type-approval test results;
− evaluation of the uncertainty of the measurement results of the ozone analyser based on the type-approval test results.
Clauses 9 to 11 and Annexes F and G are directed towards monitoring networks performing the practical
measurements of ozone in ambient air. These sections contain information about:
− initial installation of the analyser in the monitoring network and acceptance testing;
− ongoing quality assurance/quality control;
− calculation and reporting of measurement results;
− evaluation of the uncertainty of measurement results under practical monitoring conditions.

  • Standard
    114 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a continuous measurement method for the determination of the concentration of sulfur dioxide present in ambient air based on the ultraviolet fluorescence measuring principle. This document describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate ultraviolet fluorescence analyser by means of type testing. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality assurance for use.
The method is applicable to the determination of the mass concentration of sulphur dioxide present in ambient air up to 1000 µg/m3. This concentration range represents the certification range for sulfur dioxide for type testing.
NOTE 1   It is possible to use other ranges depending on the levels present in ambient air.
NOTE 2   When this document is used for purposes other than for measurements required by Directive 2008/50/EC, the ranges and uncertainty requirements possibly do not apply.
The method covers the determination of ambient air concentrations of sulfur dioxide in locations classified as rural areas, urban-background areas, and for sampling influenced by traffic or industrial sources.
The results are expressed in µg/m3 (at 20 °C and 101,3 kPa).
NOTE 3   1 000 µg/m3 of SO2 corresponds to 376 nmol/mol of SO2.
This document contains information for different groups of users.
Clause 5 to Clause 7 and Annex C and Annex D contain general information about the principles of sulfur dioxide measurement by ultraviolet fluorescence analyser and sampling equipment.
Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type testing of sulfur dioxide analysers. These sections contain information about:
—   type testing conditions, test procedures and test requirements;
—   analyser performance requirements;
—   evaluation of the type testing results;
—   evaluation of the uncertainty of the measurement results of the sulfur dioxide analyser based on the type testing results.
Clause 9 to Clause 11 and Annex F and Annex G are directed towards monitoring networks performing the practical measurements of sulfur dioxide in ambient air. These sections contain information about:
—   initial installation of the analyser in the monitoring network and acceptance testing;
—   ongoing quality assurance/quality control;
—   calculation and reporting of measurement results;
—   evaluation of the uncertainty of the measurement results under practical monitoring conditions.
This document represents an evolution of earlier editions (EN 14212:2005 and EN 14212:2012). It is advisable that when equipment is procured it complies fully with this document.
NOTE 4   Type testing performed prior to the publication of this document for the purpose of demonstrating equivalence are still valid.
NOTE 5   Analysers type tested prior to the publication of this document remain valid for use for regulated monitoring purposes.

  • Standard
    124 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a continuous measurement method for the determination of the concentration of carbon monoxide present in ambient air based on the non-dispersive infrared spectroscopic measuring principle.
This standard describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate non-dispersive infrared spectroscopic analyser by means of type approval tests. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality assurance for use.
The method is applicable to the determination of the mass concentration of carbon monoxide present in ambient air up to 100 mg/m3 carbon monoxide. This concentration range represents the certification range for the type approval test.
NOTE 1 Other ranges may be used depending on the levels present in ambient air.
NOTE 2 When the standard is used for other purposes than for measurements required by Directive 2008/50/EC, the ranges and uncertainty requirements may not apply.
The method covers the determination of ambient air concentrations of carbon monoxide in zones classified as rural areas, urban-background areas and traffic-orientated locations and locations influenced by industrial sources.
The results are expressed in mg/m3 (at 20 °C and 101,3 kPa).
NOTE 3 100 mg/m3 of CO corresponds to 86 μmol/mol of CO.
This standard contains information for different groups of users.
Clauses 5 to 7 and Annexes B, C and D contain general information about the principles of carbon monoxide measurement by non-dispersive infrared spectroscopic analyser and sampling equipment.
Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type-approval testing of carbon monoxide analysers. These sections contain information about:
− type-approval test conditions, test procedures and test requirements;
− analyser performance requirements;
− evaluation of the type-approval test results;
− evaluation of the uncertainty of the measurement results of the carbon monoxide analyser based on the type approval test results.
Clauses 9 to 11 and Annex F are directed towards monitoring networks performing the practical measurements of carbon monoxide in ambient air. These sections contain information about:
− initial installation of the analyser in the monitoring network and acceptance testing;
− ongoing quality assurance/quality control;
− calculation and reporting of measurement results;
− evaluation of the uncertainty of measurement results under practical monitoring conditions.

  • Standard
    105 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a continuous measurement method for the determination of the concentrations of nitrogen dioxide and nitrogen monoxide present in ambient air based on the chemiluminescence measuring principle. This document describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate chemiluminescence analyser by means of type testing. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality assurance for use.
The method is applicable to the determination of the concentration of nitrogen dioxide present in ambient air up to 500 µg/m3. This concentration range represents the certification range for nitrogen dioxide for type testing.
The method is applicable to the determination of the concentration of nitrogen monoxide present in ambient air up to 1 200 µg/m3. This concentration range represents the certification range for nitrogen monoxide for the type testing.
NOTE 1   It is possible to use other ranges depending on the levels present in ambient air.
NOTE 2   When this document is used for purposes other than for measurements required by Directive2008/50/EC, the ranges and uncertainty requirements possibly do not apply.
The method covers the determination of ambient air concentrations of nitrogen dioxide and nitrogen monoxide in zones classified as rural areas, urban-background areas, traffic-orientated locations and locations influenced by industrial sources.
The results are expressed in µg/m3 (at 20 °C and 101,3 kPa).
NOTE 3   500 µg/m3 of nitrogen dioxide corresponds to 261 nmol/mol of nitrogen dioxide at 20 °C and 101,3 kPa. 1 200 µg/m3 of nitrogen monoxide corresponds to 962 nmol/mol of nitrogen monoxide at 20 °C and 101,3 kPa.
This document contains information for different groups of users.
Clause 5 to Clause 7 and Annex B and Annex C contain general information about the principles of NOx measurement by chemiluminescence analyser and sampling equipment.
Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type testing of NOx analysers. These sections contain information about:
—   type testing conditions, test procedures and test requirements;
—   analyser performance requirements;
—   evaluation of the type testing results;
—   evaluation of the uncertainty of the measurement results of the NOx analyser based on the type testing results.
Clause 9 to Clause 11 and Annex F and Annex G are directed towards monitoring networks performing the practical measurements of NOx in ambient air. These sections contain information about:
—   initial installation of the analyser in the monitoring network and acceptance testing;
—   ongoing quality assurance/quality control;
—   calculation and reporting of measurement results;
—   evaluation of the uncertainty of measurement results under practical monitoring conditions.
This document represents an evolution of earlier editions (EN 14211:2005 and EN 14211:2012). It is advisable that when equipment is procured it complies fully with this document.
NOTE 4   Type testing performed prior to the publication of this document for the purpose of demonstrating equivalence are still valid.
NOTE 5   Analysers type tested prior to the publication of this document remain valid for use for regulated monitoring purposes.

  • Standard
    120 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the general principles, including testing procedures and requirements, for the classification of performance of low-cost sensor systems for the monitoring of particulate matter in ambient air at fixed sites. The classification of sensor systems includes tests that are performed under prescribed conditions. It does not guarantee performance in locations that are different from the tests, variations in meteorological climate from the test programme or account for stability over time, which can only be assessed under ongoing quality control strategies.
The described procedure is applicable to the determination of the mass concentration of particulate matter. The pollutants that are considered in this document are PM10 and PM2,5 in the range of concentrations expected in ambient air.
This document provides a classification that is consistent with the requirements for indicative measurements and objective estimation defined in Directive 2008/50/EC. In addition, it provides a classification for applications (non-regulatory measurements) that require more relaxed performance criteria.
This document applies to sensor systems used as individual systems. It does not apply to sensor systems as part of a sensor network. However, for some applications (e.g. in cities) sensor systems are deployed as part of a sensor network. Annex A provides information on the use of sensor systems as nodes in a sensor network.

  • Technical specification
    55 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a process for the electrical diffusion charging of aerosols with subsequent measurement of particle charge. With the aid of this method, it is possible to determine the lung-deposited surface area (LDSA) concentration of particles in ambient air. Depending on the design of the electrical diffusion charger, the LDSA of particles in the size range of approximately 20 nm to approximately 300 nm is measurable.
Furthermore, this document specifies design criteria for LDSA measuring aerosol monitors as well as performance criteria and the associated test procedures. The performance criteria depend on the application and they are more stringent when the instrument is operated in an air quality monitoring station.
In the determination of the LDSA concentration, the share of geometric particle surface area concentration is determined that can be deposited in the alveolar region of the human lung. Typical particle surface area concentrations with alveolar deposition measured in urban areas range from 5 µm2/cm3 to 50 µm2/cm3.
Instruments based on this measurement principle can be designed to be very compact with a low power consumption. This makes them ideally suited for handheld measurements, other forms of mobile application or to measure personal exposure. On the other hand, they can be easily adapted to serve as a stationary instrument in air quality monitoring stations.

  • Technical specification
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the general principles, including testing procedures and requirements, for the classification of performance of low-cost sensor systems for the monitoring of particulate matter in ambient air at fixed sites. The classification of sensor systems includes tests that are performed under prescribed conditions. It does not guarantee performance in locations that are different from the tests, variations in meteorological climate from the test programme or account for stability over time, which can only be assessed under ongoing quality control strategies.
The described procedure is applicable to the determination of the mass concentration of particulate matter. The pollutants that are considered in this document are PM10 and PM2,5 in the range of concentrations expected in ambient air.
This document provides a classification that is consistent with the requirements for indicative measurements and objective estimation defined in Directive 2008/50/EC. In addition, it provides a classification for applications (non-regulatory measurements) that require more relaxed performance criteria.
This document applies to sensor systems used as individual systems. It does not apply to sensor systems as part of a sensor network. However, for some applications (e.g. in cities) sensor systems are deployed as part of a sensor network. Annex A provides information on the use of sensor systems as nodes in a sensor network.

  • Technical specification
    55 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a process for the electrical diffusion charging of aerosols with subsequent measurement of particle charge. With the aid of this method, it is possible to determine the lung-deposited surface area (LDSA) concentration of particles in ambient air. Depending on the design of the electrical diffusion charger, the LDSA of particles in the size range of approximately 20 nm to approximately 300 nm is measurable.
Furthermore, this document specifies design criteria for LDSA measuring aerosol monitors as well as performance criteria and the associated test procedures. The performance criteria depend on the application and they are more stringent when the instrument is operated in an air quality monitoring station.
In the determination of the LDSA concentration, the share of geometric particle surface area concentration is determined that can be deposited in the alveolar region of the human lung. Typical particle surface area concentrations with alveolar deposition measured in urban areas range from 5 µm2/cm3 to 50 µm2/cm3.
Instruments based on this measurement principle can be designed to be very compact with a low power consumption. This makes them ideally suited for handheld measurements, other forms of mobile application or to measure personal exposure. On the other hand, they can be easily adapted to serve as a stationary instrument in air quality monitoring stations.

  • Technical specification
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a measurement method based on an automatic method for determination of the mass concentration of formaldehyde in ducts and stacks emitting to the atmosphere. It specifies the sampling and gas conditioning system. Furthermore, it specifies the characteristics to be determined and the performance criteria to be fulfilled by portable automated measuring systems (P-AMS) using appropriate techniques to measure formaldehyde.
This method is intended for intermittent monitoring of formaldehyde emissions as well as for the calibration and validation of automated formaldehyde measuring systems.
The analyser is calibrated using test gases produced by a test gas generator.

  • Technical specification
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides definitions of the quantities measured by various candidate methods, their basic principles, and their advantages and disadvantages.
Currently no traceable primary reference materials are available for EC and OC analyses. This document provides guidance to test the equivalence between candidate methods and EN 16909 for EC and/or OC determination(s), based on EN 16450.

  • Technical report
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a standard method for determining the particle number concentration in ambient air in a range up to about 107 cm–3 for averaging times equal to or larger than 1 min. The standard method is based on a Condensation Particle Counter (CPC) operated in the counting mode and an appropriate dilution system for concentrations exceeding the counting mode range. It also defines the performance characteristics and the minimum requirements of the instruments to be used. The lower and upper sizes considered within this document are 10 nm and a few micrometres, respectively. This document gives guidance on sampling, operation, data processing and QA/QC procedures including calibration parameters.

  • Standard
    56 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a standard method for determining the particle number concentration in ambient air in a range up to about 107 cm–3 for averaging times equal to or larger than 1 min. The standard method is based on a Condensation Particle Counter (CPC) operated in the counting mode and an appropriate dilution system for concentrations exceeding the counting mode range. It also defines the performance characteristics and the minimum requirements of the instruments to be used. The lower and upper sizes considered within this document are 10 nm and a few micrometres, respectively. This document gives guidance on sampling, operation, data processing and QA/QC procedures including calibration parameters.

  • Standard
    56 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides definitions of the quantities measured by various candidate methods, their basic principles, and their advantages and disadvantages.
Currently no traceable primary reference materials are available for EC and OC analyses. This document provides guidance to test the equivalence between candidate methods and EN 16909 for EC and/or OC determination(s), based on EN 16450.

  • Technical report
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a measurement method based on an automatic method for determination of the mass concentration of formaldehyde in ducts and stacks emitting to the atmosphere. It specifies the sampling and gas conditioning system. Furthermore, it specifies the characteristics to be determined and the performance criteria to be fulfilled by portable automated measuring systems (P-AMS) using appropriate techniques to measure formaldehyde.
This method is intended for intermittent monitoring of formaldehyde emissions as well as for the calibration and validation of automated formaldehyde measuring systems.
The analyser is calibrated using test gases produced by a test gas generator.

  • Technical specification
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives general guidance for the sampling and analysis of benzene in air by pumped sampling, thermal desorption and capillary gas chromatography.
This document is in accordance with the generic methodology selected as the basis of the European Union reference method for the determination of benzene in ambient air [1] for the purpose of comparison of measurement results with limit values with a one-year reference period.
This document is valid for the measurement of benzene in a concentration range of approximately 0,5 μg/m3 to 50 μg/m3. Air samples are typically collected over periods ranging from a few hours to 7 days.
The upper limit of the useful range is set by the sorptive capacity (the safe sampling volume) of the sorbent and by the linear dynamic range of the gas chromatograph column and detector or by the sample splitting capacity of the analytical instrumentation used. The lower limit of the useful range depends on the noise level of the detector and on blank levels of benzene and/or interfering artefacts on the sorbent. Artefacts are typically sub ng for graphitised carbon sorbents, but higher levels of aromatic hydrocarbons have been noted in other sorbents - e.g. porous polymers. The detection limit will be approximately 1/10 of the lower concentration range.
This document provides general guidance for the sampling of benzene using either a single sampler, which is changed manually after every exposure period, or a multi-sampler capable of storing and exposing multiple samples without user intervention.

  • Standard
    72 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives general guidance for the sampling and analysis of benzene in air by pumped sampling, thermal desorption and capillary gas chromatography.
This document is in accordance with the generic methodology selected as the basis of the European Union reference method for the determination of benzene in ambient air [1] for the purpose of comparison of measurement results with limit values with a one-year reference period.
This document is valid for the measurement of benzene in a concentration range of approximately 0,5 μg/m3 to 50 μg/m3. Air samples are typically collected over periods ranging from a few hours to 7 days.
The upper limit of the useful range is set by the sorptive capacity (the safe sampling volume) of the sorbent and by the linear dynamic range of the gas chromatograph column and detector or by the sample splitting capacity of the analytical instrumentation used. The lower limit of the useful range depends on the noise level of the detector and on blank levels of benzene and/or interfering artefacts on the sorbent. Artefacts are typically sub ng for graphitised carbon sorbents, but higher levels of aromatic hydrocarbons have been noted in other sorbents - e.g. porous polymers. The detection limit will be approximately 1/10 of the lower concentration range.
This document provides general guidance for the sampling of benzene using either a single sampler, which is changed manually after every exposure period, or a multi-sampler capable of storing and exposing multiple samples without user intervention.

  • Standard
    72 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the general principles of certification, including common procedures and requirements, for the certification of air quality monitoring equipment (AQME).
This document applies to the certification of AQME for ambient air quality and emissions from stationary sources for which performance criteria and test procedures are available in European Standards.
This document provides for the certification of AQME according to the requirements of EN ISO/IEC 17065:2012.
This document elaborates and supplements the requirements of EN ISO/IEC 17065:2012 for bodies certifying AQME. It specifies requirements on testing laboratories as well as the manufacturer’s quality management system (QMS) and the surveillance for the manufacturing process as part of the certification process.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for the manufacturer’s quality management system (QMS), the initial assessment of the manufacturer’s production control and the continuing surveillance of the effect of subsequent changes on the performance of certified air quality monitoring equipment (AQME).
This document also serves as a reference document for auditing the manufacturer’s QMS.
This document elaborates and supplements the requirements of EN ISO 9001:2015.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard describes a standard method for determining the PM10 or PM2,5 mass concentrations of suspendedparticulate matter in ambient air by sampling the particulate matter on filters and weighing them by means of a balance.
Measurements are performed with samplers with inlet designs as specified in Annex A, operating at a nominal flow rate of 2,3 m3/h,over a nominal sampling period of 24 h. Measurement results are expressed in μg/m3, where the volume of air is the volume atambient conditions near the inlet at the time of sampling.
The range of application of this European Standard is for 24 h measurements from approximately 1 μg/m3 (i.e. the limit of detection ofthe standard measurement method expressed as its uncertainty) up to 150 μg/m3 for PM10 and 120 μg/m3 for PM2,5.
This European Standard describes procedures and gives requirements for the testing and use of so-called sequential samplers,equipped with a filter changer, suitable for extended stand-alone operation. Sequential samplers are commonly used throughout theEuropean Union for the measurement of concentrations in ambient air of PM10 or PM2,5. However, this European Standard does notexclude the use of single-filter samplers.
This European Standard represents an evolution of earlier European Standards (EN 12341:1998 and 2014, EN 14907:2005). Newequipment procured shall comply fully with this European Standard.
Older versions of these samplers, including those described in EN 12341:2014 Annex B, have a special status in terms of their use. These samplers can still be used for monitoring purposes and for ongoing quality control, provided that a well justified additionalallowance is made to their uncertainties
This European Standard also provides guidance for the selection and testing of filters with the aim of reducing the measurementuncertainty of the results obtained when applying this European Standard.

  • Standard
    61 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard describes a standard method for determining the PM10 or PM2,5 mass concentrations of suspendedparticulate matter in ambient air by sampling the particulate matter on filters and weighing them by means of a balance.
Measurements are performed with samplers with inlet designs as specified in Annex A, operating at a nominal flow rate of 2,3 m3/h,over a nominal sampling period of 24 h. Measurement results are expressed in μg/m3, where the volume of air is the volume atambient conditions near the inlet at the time of sampling.
The range of application of this European Standard is for 24 h measurements from approximately 1 μg/m3 (i.e. the limit of detection ofthe standard measurement method expressed as its uncertainty) up to 150 μg/m3 for PM10 and 120 μg/m3 for PM2,5.
This European Standard describes procedures and gives requirements for the testing and use of so-called sequential samplers,equipped with a filter changer, suitable for extended stand-alone operation. Sequential samplers are commonly used throughout theEuropean Union for the measurement of concentrations in ambient air of PM10 or PM2,5. However, this European Standard does notexclude the use of single-filter samplers.
This European Standard represents an evolution of earlier European Standards (EN 12341:1998 and 2014, EN 14907:2005). Newequipment procured shall comply fully with this European Standard.
Older versions of these samplers, including those described in EN 12341:2014 Annex B, have a special status in terms of their use. These samplers can still be used for monitoring purposes and for ongoing quality control, provided that a well justified additionalallowance is made to their uncertainties
This European Standard also provides guidance for the selection and testing of filters with the aim of reducing the measurementuncertainty of the results obtained when applying this European Standard.

  • Standard
    61 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the general principles of certification, including common procedures and requirements, for the certification of air quality monitoring equipment (AQME).
This document applies to the certification of AQME for ambient air quality and emissions from stationary sources for which performance criteria and test procedures are available in European Standards.
This document provides for the certification of AQME according to the requirements of EN ISO/IEC 17065:2012.
This document elaborates and supplements the requirements of EN ISO/IEC 17065:2012 for bodies certifying AQME. It specifies requirements on testing laboratories as well as the manufacturer’s quality management system (QMS) and the surveillance for the manufacturing process as part of the certification process.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for the manufacturer’s quality management system (QMS), the initial assessment of the manufacturer’s production control and the continuing surveillance of the effect of subsequent changes on the performance of certified air quality monitoring equipment (AQME).
This document also serves as a reference document for auditing the manufacturer’s QMS.
This document elaborates and supplements the requirements of EN ISO 9001:2015.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document supports the elaboration of standardized measurement methods for the determination of stationary source emissions by manual or automated measurement methods.
This document describes the basic elements of standardized measurement methods for the determination of stationary source emissions.
This document is supplemented by an electronic template providing a uniform structure and common elements and texts.
NOTE   Detailed information on the electronic template is given in Annex A.
This document is addressed to working groups of CEN/TC 264 dealing with stationary source emissions. It aims at facilitating in the working groups the elaboration and the harmonization of documents produced by CEN/TC 264. Such documents can be European standards (EN), European Technical Specifications (CEN/TS) or European Technical Reports (CEN/TR).

  • Technical report
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document supports the elaboration of standardized measurement methods for the determination of stationary source emissions by manual or automated measurement methods.
This document describes the basic elements of standardized measurement methods for the determination of stationary source emissions.
This document is supplemented by an electronic template providing a uniform structure and common elements and texts.
NOTE   Detailed information on the electronic template is given in Annex A.
This document is addressed to working groups of CEN/TC 264 dealing with stationary source emissions. It aims at facilitating in the working groups the elaboration and the harmonization of documents produced by CEN/TC 264. Such documents can be European standards (EN), European Technical Specifications (CEN/TS) or European Technical Reports (CEN/TR).

  • Technical report
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the general principles, including testing procedures and requirements, for the classification of performance of low-cost sensor systems for the monitoring of gaseous compounds in ambient air at fixed sites. The classification of sensor systems includes tests that are performed under prescribed laboratory and field conditions.
The procedure described is applicable to the determination of the mass concentration of air pollutants. The pollutants that are considered in this document are the gaseous pollutants regulated under Directive 2008/50/EC (O3, NO/NO2/NOx, CO, SO2 and benzene) in the range of concentrations expected in ambient air.
This document provides a classification that is consistent with the requirements for indicative measurements and objective estimation defined in Directive 2008/50/EC. In addition, it provides a classification for applications (non-regulatory measurements) that require more relaxed performance criteria.
This document applies to sensor systems used as individual systems. It does not apply to sensor systems as part of a sensor network. However, for some applications (e.g. in cities) sensor systems are deployed as part of a sensor network. Annex A gives information on the use of sensor systems as nodes in a sensor network.
This document gives guidance on the testing of CO2 sensor systems in Annex B since, although not listed in Directive 2008/50/EC, CO2 is an interesting indicator as proxy for activities involving combustion processes or for CO2 evaporation from soil or water.

  • Technical specification
    88 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the general principles, including testing procedures and requirements, for the classification of performance of low-cost sensor systems for the monitoring of gaseous compounds in ambient air at fixed sites. The classification of sensor systems includes tests that are performed under prescribed laboratory and field conditions.
The procedure described is applicable to the determination of the mass concentration of air pollutants. The pollutants that are considered in this document are the gaseous pollutants regulated under Directive 2008/50/EC (O3, NO/NO2/NOx, CO, SO2 and benzene) in the range of concentrations expected in ambient air.
This document provides a classification that is consistent with the requirements for indicative measurements and objective estimation defined in Directive 2008/50/EC. In addition, it provides a classification for applications (non-regulatory measurements) that require more relaxed performance criteria.
This document applies to sensor systems used as individual systems. It does not apply to sensor systems as part of a sensor network. However, for some applications (e.g. in cities) sensor systems are deployed as part of a sensor network. Annex A gives information on the use of sensor systems as nodes in a sensor network.
This document gives guidance on the testing of CO2 sensor systems in Annex B since, although not listed in Directive 2008/50/EC, CO2 is an interesting indicator as proxy for activities involving combustion processes or for CO2 evaporation from soil or water.

  • Technical specification
    88 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The European Directive on ambient air quality and cleaner air for Europe (2008/50/EC; AQD) identifies different uses for modelling: Assessment, planning, forecast and source apportionment (SA). This document addresses source apportionment modelling and specifies performance tests to check whether given criteria for receptor oriented source apportionment models (RM) are met. The scope of the tests set out in this document is the performance assessment of SA of particulate matter using RM in the context of the European Directives 2004/107/EC and AQD, including the Commission Implementing Decision 2011/850/EU of 12 December 2011. The application of RM does not quantify the spatial origin of particulate matter; hence, this document does not test spatial SA.
This document addresses RM users: practitioners of individual source apportionment studies as well as participants and organizers of source apportionment intercomparison studies. This document is suitable for the evaluation of results of a specific SA modelling system with respect to reference values (a priori known or calculated on the basis of intercomparison participants' values) in the following application areas:
-   Assessment of performance and uncertainties of a modelling system or modelling system set up using the indicators laid down in this document.
-   Testing and comparing different source apportionment outputs in a specific situation (applying an evaluation data set) using the indicators laid down in this document.
-   QA/QC tests every time practitioners run a modelling system.
It should be noted for clarity that the procedures and calculations presented in this document cannot be used to check the performance of a specific SA modelling result without having any a priori reference information about the contributions of sources/source categories.
NOTE   The application of this document implies that the intercomparison is organized and coordinated by an institution with the necessary technical capabilities and independence; the definition of which is beyond the scope of this document.
The principles of RM are summarized in Annex A. An overview of uncertainty sources and recommendations about steps to follow in SA studies are provided in Annex B and Annex C. For further information about SA methodologies, refer to e.g. [1; 2; 3].
There are methodologies different from RM which are widely used to accomplish SA, e.g. source oriented models. These other methodologies cover aspects of SA which are required in the AQD and are not addressed by RM (e.g. allocation of pollutants to geographic emission areas). Performance assessment of such methodologies is out of the scope of this document.

  • Technical specification
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The European Directive on ambient air quality and cleaner air for Europe (2008/50/EC; AQD) identifies different uses for modelling: Assessment, planning, forecast and source apportionment (SA). This document addresses source apportionment modelling and specifies performance tests to check whether given criteria for receptor oriented source apportionment models (RM) are met. The scope of the tests set out in this document is the performance assessment of SA of particulate matter using RM in the context of the European Directives 2004/107/EC and AQD, including the Commission Implementing Decision 2011/850/EU of 12 December 2011. The application of RM does not quantify the spatial origin of particulate matter; hence, this document does not test spatial SA.
This document addresses RM users: practitioners of individual source apportionment studies as well as participants and organizers of source apportionment intercomparison studies. This document is suitable for the evaluation of results of a specific SA modelling system with respect to reference values (a priori known or calculated on the basis of intercomparison participants' values) in the following application areas:
-   Assessment of performance and uncertainties of a modelling system or modelling system set up using the indicators laid down in this document.
-   Testing and comparing different source apportionment outputs in a specific situation (applying an evaluation data set) using the indicators laid down in this document.
-   QA/QC tests every time practitioners run a modelling system.
It should be noted for clarity that the procedures and calculations presented in this document cannot be used to check the performance of a specific SA modelling result without having any a priori reference information about the contributions of sources/source categories.
NOTE   The application of this document implies that the intercomparison is organized and coordinated by an institution with the necessary technical capabilities and independence; the definition of which is beyond the scope of this document.
The principles of RM are summarized in Annex A. An overview of uncertainty sources and recommendations about steps to follow in SA studies are provided in Annex B and Annex C. For further information about SA methodologies, refer to e.g. [1; 2; 3].
There are methodologies different from RM which are widely used to accomplish SA, e.g. source oriented models. These other methodologies cover aspects of SA which are required in the AQD and are not addressed by RM (e.g. allocation of pollutants to geographic emission areas). Performance assessment of such methodologies is out of the scope of this document.

  • Technical specification
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document describes procedures to assess the applicability of the standard method EN 16909 (determination of OC and EC deposited on filters) to particle size fractions up to 10 µm in aerodynamic diameter (50 % cut off).

  • Technical report
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document describes procedures to assess the applicability of the standard method EN 16909 (determination of OC and EC deposited on filters) to particle size fractions up to 10 µm in aerodynamic diameter (50 % cut off).

  • Technical report
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides
• information, guidance and specifications on how
o to set up an air quality and emissions management policy;
o to deploy reliable and scalable technologies to monitor air quality on a continuous or regular basis;
o to react with adequate measures;
o to specify air quality levels for triggering a scenario;
• a toolkit of parameters and data definitions that a regulator can use;
• means to measure the air quality required by relevant EU directives
• to specify use of TS Intelligent transport systems - Urban-ITS - 'Controlled Zone' management using C-ITS, for the purposes of geofenced controlled zones for emissions management
NOTE: In order to maximise European harmonisation, it is recommended that this specification is used in combination with a module of standardised data concepts, however, this version of this document, which is focussed on policies and procedures, does not provide these data concept specifications.

  • Technical specification
    57 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides
• information, guidance and specifications on how
o to set up an air quality and emissions management policy;
o to deploy reliable and scalable technologies to monitor air quality on a continuous or regular basis;
o to react with adequate measures;
o to specify air quality levels for triggering a scenario;
• a toolkit of parameters and data definitions that a regulator can use;
• means to measure the air quality required by relevant EU directives
• to specify use of TS Intelligent transport systems - Urban-ITS - 'Controlled Zone' management using C-ITS, for the purposes of geofenced controlled zones for emissions management
NOTE: In order to maximise European harmonisation, it is recommended that this specification is used in combination with a module of standardised data concepts, however, this version of this document, which is focussed on policies and procedures, does not provide these data concept specifications.

  • Technical specification
    57 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for the determination of the mass concentration of water soluble NO3- (nitrate), SO42- (sulphate), Cl- (chloride), NH4+ (ammonium), Na+ (sodium), K+ (potassium), Mg2+ (magnesium), Ca2+ (calcium) in PM2,5 as deposited on filters.
This European Standard describes the analytical procedures for determining anions and cations as part of the PM2,5 particulate phase, sample extraction and analysis of anions and cations by ion chromatography. Sampling onto filters will be done in accordance with EN 12341 for PM2,5.
NOTE 1   Alternatively, cations, excluding ammonium, can be analysed by inductively coupled plasma optical emission spectrometry (ICP-OES). Ammonium can also be analysed by photometry or conductometry.
This European Standard can be used for the measurements of anions and cations as required by Directive 2008/50/EC. The method does not take into account the possible losses during sampling due to evaporation.
NOTE 2   NO3-, Cl-, NH4+ are part of the volatile fraction of PM2,5, and the concentrations determined using this standard can be used as minimum values for the concentrations of these ions in PM2,5. NO3-, NH4+, Cl- are usually up to 30 % underestimated due to evaporational losses from the filter during sampling.
This European Standard may be used at rural and urban background sites and road sites that are in accordance with the siting criteria of Directive 2008/50/EC.
This European Standard is applicable to the measurement of anion/cations in PM2,5 samples corresponding to PM2,5 mass concentrations between approximately 1 μg/m3 (i.e. the limit of detection of the standard measurement method (EN 12341) expressed as its uncertainty) up to 120 μg/m3.
The validated range of the anion and cation concentrations based on the field validation measurements is presented in Table 1.
(...)
See Annex A for the statistical analysis of the field validation measurements.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

In order to be in compliance with EU Air Quality Directive requirements, the reference methods given in the Directive 2008/50/EC [1] for the measurement of mass concentrations of particulate matter are not commonly used for operation in routine monitoring networks. These networks usually apply automated continuous measurement systems (AMS), such as those based on the use of oscillating microbalances, ß-ray attenuation, or in-situ optical methods. Such AMS are typically capable of producing 24-hour average measurement values over a measurement range up to 1 000 µg/m3 and 1-hour average measurement values up to 10 000 µg/m3, if applicable, where the volume of air is the volume at ambient conditions near the inlet at the time of sampling.
The 1-hour average values may be used for:
a)   direct information of the public;
b)   aggregation to produce daily or yearly average concentration values for regulatory reporting purposes.
Directive 2008/50/EC allows the use of such systems after demonstration of equivalence with the reference method, i.e. after demonstration that these systems meet the Data Quality Objectives for continuous measurements. Guidelines for the demonstration of equivalence are given in Reference [2].
This European Standard lays down the minimum performance requirements and test procedures for the type approval of appropriate AMS for particulate matter. This includes the evaluation of its equivalence with the reference method as laid down in Directive 2008/50/EC.
Further, this European Standard describes minimum requirements for ongoing quality assurance – quality control (QA/QC) of AMS deployed in the field. These requirements are necessary to ensure that uncertainties of measured concentrations are kept within the required limits during extended periods of continuous monitoring in the field, and include procedures for maintenance, calibration and control checks.
Additional procedures are described that determine whether an instrument’s equivalence to the reference method is maintained through possible pollution climate changes, over periods longer than five years.
Lastly, this European Standard describes harmonized requirements and procedures for the treatment and validation of raw measurement data that are used for the assembly of daily or yearly average concentration values. Experience with existing methods for data treatment and validation – for similar AMS – has shown that the different ways of data treatment and validation applied may lead to significant differences in reported results for similar datasets [3].
When the European Standard is used for purposes other than measurements required by Directive 2008/50/EC, the range and uncertainty requirements may not apply.
This European Standard contains information for different groups of users.
Clauses 5 and 6 and Annex A contain general information about the principles of automated continuous measurement systems for particulate matter, and relevant equipment.
Clause 7 and Annexes B and C are specifically directed towards test houses and laboratories that perform type-approval testing of automated continuous measurement systems for particulate matter. These clauses contain information about:
c)   type-approval test conditions, test procedures and test requirements;
d)   system performance requirements;
e)   evaluation of the type-approval test results;
f)   evaluation of the uncertainty of the measurement results of the automated continuous measurement systems for particulate matter based on the type-approval test results.
Clauses 8 to 11 are aimed at monitoring networks performing the practical measurements of particulate matter in ambient air. These clauses contain information about:
g)   initial installation of the system in the monitoring network and acceptance testing;
h)   ongoing quality assurance/quality control;
i)   on-going verification of suitability;
j)   treatment, validation and reporting of measurement results.

  • Standard
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard gives guidance on the measurement of elemental carbon (EC) and organic carbon (OC) following the requirement for the networks of all EU member states to measure EC and OC in particulate matter from June 2010 at background sites according to the Council Directive 2008/50/EC on ambient air quality and cleaner air for Europe [1].
This European Standard describes the analytical procedures for determining EC and OC on quartz fibre filters as μg/cm2, and the subsequent calculation of concentrations as µg/m3. Sampling onto filters is to be done in accordance with EN 12341:2014 for PM2,5. The sampling process determines the size fraction of the particulate matter, the retention of semi-volatile material, and uptake/loss of volatile organic compounds on the filter at the time of sampling.
The same analysis method may also be used for smaller size fractions than PM2,5. Any possible additional artefacts for larger particles, e.g. pyrolysis or higher concentrations of carbonates, should be assessed.
The scope includes rural background, urban background, road side and industrial measurement sites, to allow the assessment of additional exposure of people in urban areas as stated in the objectives of the council directive and to achieve coherence in the European approach.
The applicable concentration range of the proposed method is limited by the optical correction and instrument applied in the analysis of EC and OC. This method was validated from 0,2 µg CEC/cm² and 1,8 µg COC/cm² to 38 µg CEC/cm² and 49 µg COC/cm² in the laboratory and to 16 µg CEC/cm² and 45 µg COC/cm² in the field.

  • Standard
    56 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a method for the determination of the mass concentration of water soluble NO3- (nitrate), SO42- (sulphate), Cl- (chloride), NH4+ (ammonium), Na+ (sodium), K+ (potassium), Mg2+ (magnesium), Ca2+ (calcium) in PM2,5 as deposited on filters.
This European Standard describes the analytical procedures for determining anions and cations as part of the PM2,5 particulate phase, sample extraction and analysis of anions and cations by ion chromatography. Sampling onto filters will be done in accordance with EN 12341 for PM2,5.
NOTE 1   Alternatively, cations, excluding ammonium, can be analysed by inductively coupled plasma optical emission spectrometry (ICP-OES). Ammonium can also be analysed by photometry or conductometry.
This European Standard can be used for the measurements of anions and cations as required by Directive 2008/50/EC. The method does not take into account the possible losses during sampling due to evaporation.
NOTE 2   NO3-, Cl-, NH4+ are part of the volatile fraction of PM2,5, and the concentrations determined using this standard can be used as minimum values for the concentrations of these ions in PM2,5. NO3-, NH4+, Cl- are usually up to 30 % underestimated due to evaporational losses from the filter during sampling.
This European Standard may be used at rural and urban background sites and road sites that are in accordance with the siting criteria of Directive 2008/50/EC.
This European Standard is applicable to the measurement of anion/cations in PM2,5 samples corresponding to PM2,5 mass concentrations between approximately 1 μg/m3 (i.e. the limit of detection of the standard measurement method (EN 12341) expressed as its uncertainty) up to 120 μg/m3.
The validated range of the anion and cation concentrations based on the field validation measurements is presented in Table 1.
(...)
See Annex A for the statistical analysis of the field validation measurements.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard gives guidance on the measurement of elemental carbon (EC) and organic carbon (OC) following the requirement for the networks of all EU member states to measure EC and OC in particulate matter from June 2010 at background sites according to the Council Directive 2008/50/EC on ambient air quality and cleaner air for Europe [1].
This European Standard describes the analytical procedures for determining EC and OC on quartz fibre filters as μg/cm2, and the subsequent calculation of concentrations as µg/m3. Sampling onto filters is to be done in accordance with EN 12341:2014 for PM2,5. The sampling process determines the size fraction of the particulate matter, the retention of semi-volatile material, and uptake/loss of volatile organic compounds on the filter at the time of sampling.
The same analysis method may also be used for smaller size fractions than PM2,5. Any possible additional artefacts for larger particles, e.g. pyrolysis or higher concentrations of carbonates, should be assessed.
The scope includes rural background, urban background, road side and industrial measurement sites, to allow the assessment of additional exposure of people in urban areas as stated in the objectives of the council directive and to achieve coherence in the European approach.
The applicable concentration range of the proposed method is limited by the optical correction and instrument applied in the analysis of EC and OC. This method was validated from 0,2 µg CEC/cm² and 1,8 µg COC/cm² to 38 µg CEC/cm² and 49 µg COC/cm² in the laboratory and to 16 µg CEC/cm² and 45 µg COC/cm² in the field.

  • Standard
    56 pages
    English language
    sale 10% off
    e-Library read for
    1 day

In order to be in compliance with EU Air Quality Directive requirements, the reference methods given in the Directive 2008/50/EC [1] for the measurement of mass concentrations of particulate matter are not commonly used for operation in routine monitoring networks. These networks usually apply automated continuous measurement systems (AMS), such as those based on the use of oscillating microbalances, ß-ray attenuation, or in-situ optical methods. Such AMS are typically capable of producing 24-hour average measurement values over a measurement range up to 1 000 µg/m3 and 1-hour average measurement values up to 10 000 µg/m3, if applicable, where the volume of air is the volume at ambient conditions near the inlet at the time of sampling.
The 1-hour average values may be used for:
a)   direct information of the public;
b)   aggregation to produce daily or yearly average concentration values for regulatory reporting purposes.
Directive 2008/50/EC allows the use of such systems after demonstration of equivalence with the reference method, i.e. after demonstration that these systems meet the Data Quality Objectives for continuous measurements. Guidelines for the demonstration of equivalence are given in Reference [2].
This European Standard lays down the minimum performance requirements and test procedures for the type approval of appropriate AMS for particulate matter. This includes the evaluation of its equivalence with the reference method as laid down in Directive 2008/50/EC.
Further, this European Standard describes minimum requirements for ongoing quality assurance – quality control (QA/QC) of AMS deployed in the field. These requirements are necessary to ensure that uncertainties of measured concentrations are kept within the required limits during extended periods of continuous monitoring in the field, and include procedures for maintenance, calibration and control checks.
Additional procedures are described that determine whether an instrument’s equivalence to the reference method is maintained through possible pollution climate changes, over periods longer than five years.
Lastly, this European Standard describes harmonized requirements and procedures for the treatment and validation of raw measurement data that are used for the assembly of daily or yearly average concentration values. Experience with existing methods for data treatment and validation – for similar AMS – has shown that the different ways of data treatment and validation applied may lead to significant differences in reported results for similar datasets [3].
When the European Standard is used for purposes other than measurements required by Directive 2008/50/EC, the range and uncertainty requirements may not apply.
This European Standard contains information for different groups of users.
Clauses 5 and 6 and Annex A contain general information about the principles of automated continuous measurement systems for particulate matter, and relevant equipment.
Clause 7 and Annexes B and C are specifically directed towards test houses and laboratories that perform type-approval testing of automated continuous measurement systems for particulate matter. These clauses contain information about:
c)   type-approval test conditions, test procedures and test requirements;
d)   system performance requirements;
e)   evaluation of the type-approval test results;
f)   evaluation of the uncertainty of the measurement results of the automated continuous measurement systems for particulate matter based on the type-approval test results.
Clauses 8 to 11 are aimed at monitoring networks performing the practical measurements of particulate matter in ambient air. These clauses contain information about:
g)   initial installation of the system in the monitoring network and acceptance testing;
h)   ongoing quality assurance/quality control;
i)   on-going verification of suitability;
j)   treatment, validation and reporting of measurement results.

  • Standard
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a semi-continuous measurement method for the determination of the concentration of benzene present in ambient air based on automated sampling and analysis by gas chromatography. This standard describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate automated gas chromatograph (GC) by means of type approval tests. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality assurance for use.
The method is applicable to the determination of the mass con¬centration of benzene present in ambient air in the range up to 50 µg/m3 benzene. This concentration range represents the certification range for the type approval test.
Other ranges may be used depending on the levels present in ambient air.
NOTE 1   When the standard is used for other purposes than for measurements required by Directive 2008/50/EC, the ranges and uncertainty requirements may not apply.
The method covers the determination of ambient air concentrations of benzene in zones classified as rural areas, urban-background areas and traffic-orientated locations and locations influenced by industrial sources.
The results are expressed in µg/m3 (at 20 °C and 101,3 kPa).
NOTE 2   50 µg/m3 of benzene corresponds to 15,4 nmol/mol of benzene.
This European Standard contains information for different groups of users.
Clauses 5 to 7 and Annexes C and D contain general information about the principles of benzene measurement by automated gas chromatography and sampling equipment.
Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type-approval testing of benzene analysers. These sections contain information about:
-   type-approval test conditions, test procedures and test requirements;
-   analyser performance requirements;
-   evaluation of the type-approval test results;
-   evaluation of the uncertainty of the measurement results of the benzene analyser based on the type-approval test results.
Clauses 9 to 11 and Annex F are directed towards monitoring networks performing the practical measurements of benzene in ambient air. These sections contain information about:
-   initial installation of the analyser in the monitoring network and acceptance testing;
-   ongoing quality assurance/quality control;
-   calculation and reporting of measurement results;
-   evaluation of the uncertainty of measurement results under practical monitoring conditions.

  • Standard
    72 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies a semi-continuous measurement method for the determination of the concentration of benzene present in ambient air based on automated sampling and analysis by gas chromatography. This standard describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate automated gas chromatograph (GC) by means of type approval tests. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality assurance for use.
The method is applicable to the determination of the mass con¬centration of benzene present in ambient air in the range up to 50 µg/m3 benzene. This concentration range represents the certification range for the type approval test.
Other ranges may be used depending on the levels present in ambient air.
NOTE 1   When the standard is used for other purposes than for measurements required by Directive 2008/50/EC, the ranges and uncertainty requirements may not apply.
The method covers the determination of ambient air concentrations of benzene in zones classified as rural areas, urban-background areas and traffic-orientated locations and locations influenced by industrial sources.
The results are expressed in µg/m3 (at 20 °C and 101,3 kPa).
NOTE 2   50 µg/m3 of benzene corresponds to 15,4 nmol/mol of benzene.
This European Standard contains information for different groups of users.
Clauses 5 to 7 and Annexes C and D contain general information about the principles of benzene measurement by automated gas chromatography and sampling equipment.
Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type-approval testing of benzene analysers. These sections contain information about:
-   type-approval test conditions, test procedures and test requirements;
-   analyser performance requirements;
-   evaluation of the type-approval test results;
-   evaluation of the uncertainty of the measurement results of the benzene analyser based on the type-approval test results.
Clauses 9 to 11 and Annex F are directed towards monitoring networks performing the practical measurements of benzene in ambient air. These sections contain information about:
-   initial installation of the analyser in the monitoring network and acceptance testing;
-   ongoing quality assurance/quality control;
-   calculation and reporting of measurement results;
-   evaluation of the uncertainty of measurement results under practical monitoring conditions.

  • Standard
    72 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The Report is to provide guidance on uncertainty evaluation to CEN/TC 264 Working Group(s), who are involved in the preparation of Reference Methods to measure ambient air quality, as required by the EU Daughter Directives of the European Framework Directive on Ambient Air-quality Assessment and Management (96/62/EC)

  • Standardization document
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The Report is to provide guidance on uncertainty evaluation to CEN/TC 264 Working Group(s), who are involved in the preparation of Reference Methods to measure ambient air quality, as required by the EU Daughter Directives of the European Framework Directive on Ambient Air-quality Assessment and Management (96/62/EC)

  • Standardization document
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for the manufacturer’s quality management system (QMS), the initial assessment of the manufacturer’s production control and the continuing surveillance of the effect of subsequent changes on the performance of certified air quality monitoring equipment (AQME).
This document also serves as a reference document for auditing the manufacturer’s QMS.
This document elaborates and supplements the requirements of EN ISO 9001:2015.

  • Draft
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the general principles of certification, including common procedures and requirements, for the certification of air quality monitoring equipment (AQME).
This document applies to the certification of AQME for ambient air quality and emissions from stationary sources for which performance criteria and test procedures are available in European Standards.
This document provides for the certification of AQME according to the requirements of EN ISO/IEC 17065:2012.
This document elaborates and supplements the requirements of EN ISO/IEC 17065:2012 for bodies certifying AQME. It specifies requirements on testing laboratories as well as the manufacturer’s quality management system (QMS) and the surveillance for the manufacturing process as part of the certification process.

  • Draft
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day