IEC 61754-6:2022 specifies the standard interface dimensions for type MU family of connectors. This third edition cancels and replaces the second edition published in 2013 and constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- the test method IEC 61300-3-22 for the compression force of the ferrule was added;
- Annex D (informative) with cut out dimension requirements for testing the strength of mounted adaptors was added.

  • Standard
    248 pages
    English language
    sale 15% off
  • Standard
    165 pages
    English language
    sale 15% off
  • Standard
    165 pages
    English and French language
    sale 15% off

IEC 61754-4:2021 specifies the standard interface dimensions for type SC family of connectors. This third edition cancels and replaces the second edition published in 2013 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- the test method IEC 61300-3-22 for the compression force of the ferrule was added;
- Annex A (informative) with cut out dimension requirements for testing the strength of mounted adaptors was added.

  • Standard
    112 pages
    English language
    sale 15% off
  • Standard
    69 pages
    English language
    sale 15% off
  • Standard
    73 pages
    English and French language
    sale 15% off

IEC 61753-021-03:2026 defines minimum initial test and measurement requirements and severities which single-mode fibre optic connectors terminated as a pigtail or a patchcord satisfy in order to be categorized as meeting the IEC standard category OP (outdoor protected environment), as defined in IEC 61753-1. If tests are performed on the connectors terminated as pigtails or patchcords for category OPHD, OP+ or OP+HD and the product passes these tests, the product will be automatically qualified or categorized as meeting the IEC standard for category OP. If tests are performed on the connectors terminated as pigtails or patchcords for category OP, and the product passes these tests, the product will be automatically qualified or categorized as meeting the IEC standard for category C or CHD.
This first edition cancels and replaces the first edition of IEC 61753-021-3 published in 2012.
This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) update of environmental categories (from U to OP), tests and their severities in accordance with IEC 61753‑1;
b) changes in the terms and definitions of the different types of test samples (pigtail test samples and patchcord test samples) used in the various tests to avoid confusion;
c) update of fibre naming conventions in accordance with IEC 60793‑2‑50 and addition of provisions for B‑657 fibres;
d) addition of all the attenuation and return loss grades defined in IEC 61753‑1;
e) deletion of the static side load test;
f) addition of provisions for rectangular ferrule connectors;
g) addition of the fibre optic connector proof test with static load – side pull;
h) update of the flexing of the strain relief test to use change of attenuation instead of transient loss;
i) addition of Annex B for visual examination of the outer cable sheath movement of reinforced cables as an additional requirement for change of temperature, cable retention and flexing of the strain relief tests.

  • Standard
    19 pages
    English language
    sale 15% off
  • Standard
    40 pages
    English and French language
    sale 15% off

IEC 61753-022-13:2026 defines the minimum initial test and measurement requirements, and severities which multimode fibre optic connectors terminated as a pigtail or a patchcord satisfy in order to be categorized as meeting the IEC standard category OP+HP (Extended outdoor protected environment with additional heat dissipation), as defined in IEC 61753-1.
If tests are performed on the connectors terminated as pigtails or patchcords for category OP+HP, and the product pass, the product will be automatically qualified or categorized as meeting the IEC standard for categories OP+, OP, OPHD, C and CHD.

  • Standard
    16 pages
    English language
    sale 15% off
  • Standard
    34 pages
    English and French language
    sale 15% off

IEC 61754-2: 2026 defines the standard interface dimensions for type BFOC/2,5 family of connectors.
This second edition cancels and replaces the first edition published in 1996. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) addition of Clause 2, Clause 3 and the Bibliography;
b) addition of the active device receptacle interface type;
c) revision of the ferrule grades to refer to the connector optical interfaces specified in the IEC 61755-3 series;
d) revision of the ferrule end face geometry to refer to the connector optical interfaces specified in the IEC 61755‑3 series and IEC 63267‑3 series;
e) improvement of the description of the characteristics of the resilient alignment sleeve for adaptor and rigid bore sleeve for active device receptacle;
f) harmonisation of the dimensions of reference A for the rigid bore sleeve with other connector interface standards in IEC 61754 series.

  • Standard
    11 pages
    English language
    sale 15% off
  • Standard
    22 pages
    English and French language
    sale 15% off

IEC 61753-022-02: 2026 defines the minimum initial test and measurement requirements and severities which multimode fibre optic connectors terminated as a pigtail or patchcord satisfy in order to be categorized as meeting the IEC standard category C (controlled environment), as defined in IEC 61753‑1. This first edition cancels and replaces the second edition of IEC 61753-022-2 published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) addition of provisions for rectangular ferrule connectors;
b) additions of terms and definitions;
c) update of the fibre naming conventions in accordance with IEC 60793-2-10;
d) update of test severities in accordance with IEC 61753‑1;
e) addition of the torsion test;
f) reduction of the duration of the fibre/cable retention test on reinforced cables from 120 s to 60 s minimum;
g) deletion of the static side load test;
h) update of the flexing of the strain relief test to use the change in attenuation instead of the transient loss;
i) reduction of the number of mating durability cycles for cylindrical ferrule connectors from 500 cycles to 200 cycles;
j) addition of the mating durability for rectangular ferrule connectors with 50 cycles;
k) addition of Annex B for visual examination of the outer cable sheath movement of reinforced cables as an additional requirement for change of temperature, cable retention and flexing of the strain relief tests.

  • Standard
    17 pages
    English language
    sale 15% off
  • Standard
    18 pages
    French language
    sale 15% off

IEC 61754-37:2025 defines the standard mechanical interface dimensions for the type MDC family of connectors.

  • Standard
    24 pages
    English language
    sale 15% off
  • Standard
    25 pages
    French language
    sale 15% off
  • Standard
    49 pages
    English and French language
    sale 15% off

IEC 63267-3-81: 2025 defines the dimensional limits of an optical interface for reference connectors with rectangular ferrules necessary to meet specific requirements for fibre-to-fibre interconnection of non-angled polished multimode reference connectors with rectangular ferrules intended to be used for attenuation measurements as defined in IEC 63267‑2‑2. Ferrule dimensions and features are contained in the IEC 61754 series of fibre optic interface standards.One grade of reference connector is defined in this document. The reference connector is terminated to restricted IEC 60793-2-10 A1-OM2b to A1-OM5b fibre at 850 nm band only. The geometrical dimensions and tolerances of the specified reference connector have been developed primarily to limit the variation in measured attenuation between multiple sets of two reference connectors, and therefore to limit the variation in measured attenuation between randomly chosen reference connectors when mated with connectors in the field or factory.

  • Standard
    35 pages
    English and French language
    sale 15% off

IEC 63267-3-61: 2025 defines the dimensional limits of an optical interface for reference connectors with 2,5 mm or 1,25 mm diameter cylindrical zirconia (ZrO2) ferrules necessary to meet specific requirements for fibre-to-fibre interconnection of non-angled polished multimode reference connections as defined in IEC 63267-2-2. Ferrule dimensions and features are contained in the IEC 61754 series of fibre optic connector interface standards. One grade of reference connector, Rm1, is defined in this document. The reference connector is terminated to restricted IEC 60793-2-10 using A1-OM2b to A1‑OM5b fibre in 850 nm band only. The geometrical dimensions and tolerances of the specified reference connector have been developed primarily to limit the variation in measured attenuation between multiple sets of reference connectors, and therefore to reduce the variation in measured attenuation between an arbitrarily chosen reference connector when mated with a connector in the field or factory.
This first edition and the first edition of IEC 63267-2-2 cancel and replace the first edition of IEC 61755-6-2 published in 2018. This edition constitutes a technical revision. The document includes the following significant technical changes with respect to the previous edition:
a) Definition of a reference grade, Rm1 interface;
b) Inclusion of A1-OM2b to A1-OM5b fibres;
c) Updates to normative references;
d) The addition of Annex A, which describes the attenuation test limits of reference grade Rm1 connectors to grade Bm connectors;
e) A new Annex B that describes the allowable fibre undercut.

  • Standard
    28 pages
    English and French language
    sale 15% off

IEC 61754-36:2025 defines the standard mechanical interface dimensions for the type SAC family of connectors.

  • Standard
    61 pages
    English and French language
    sale 15% off

CORRECTED VERSION 2025-06
IEC 61754-13:2024 defines the standard interface dimensions for the type FC-PC family of connectors. This third edition cancels and replaces the second edition published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) revising normative reference reflecting the latest documents;
b) addition of intermateability in 5.2;
c) changes of dimensions of the plug connector interface in Table 2 and Table 3;
d) addition of Grade Am, Bm and Cm in Table 3.
The content of the corrigendum 1 (2025-06) has been included in this copy.

  • Standard
    50 pages
    English language
    sale 15% off
  • Standard
    29 pages
    English and French language
    sale 15% off

IEC 61755-3-2:2024 defines the dimensional limits of the optical interface that are necessary for single-mode fibre optic connectors with 2,5 mm or 1,25 mm diameter cylindrical zirconia (ZrO2) ferrules polished at an 8° angle to meet the specific requirements for fibre-to-fibre interconnection, as defined in IEC 61755-2-2. Ferrules made from the material specified in this standard are suitable for use in all the operating service environments defined in IEC 61753-1. Ferrule dimensions and features are contained in the IEC 61754 series of fibre optic connector interface standards. This second edition cancels and replaces the first edition published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) normative references have been added;
b) The introduction of an additional optical interface with a different fibre core eccentricity profile. The previous revision of optical interface standard is named "Variant 1: with fibre core axis oriented towards the connector guide key".
The additional optical interface is named "Variant 2: with fibre core axis not oriented towards the connector guide key";
c) statements added related to interoperability, where both variants remain intermateable within a given performance grade and are fully backwards compatible to IEC 61755-3-2:2006;
d) The addition of Grade B and Grade C interface requirements for both variants;
f) The addition of a descriptive statistic for the mean fibre core eccentricity (mean value) to describe the distribution of fibre core eccentricity to ensure interoperability;
g) A new informative Annex B to give guidance on the expected attenuation when mated to a reference connector plug;
h) A new informative Annex D to give guidance related to estimation of mean fibre eccentricity limits for finite production batch sizes.

  • Standard
    47 pages
    English and French language
    sale 15% off

IEC 61755-3-1:2024 defines the dimensional limits of the optical interface that are necessary for single-mode fibre optic connectors with 2,5 mm or 1,25 mm diameter cylindrical zirconia (ZrO2) ferrules to meet the specific requirements for fibre-to-fibre interconnection, as defined in IEC 61755-2-1. Ferrules made from the material specified in this document are suitable for use in all the operating service environments defined in IEC 61753-1. Ferrule dimensions and features are contained in the IEC 61754 series of fibre optic connector interface standards.
This second edition cancels and replaces the first edition published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) normative references have been added;
b) the introduction of an additional optical interface with a different fibre core eccentricity profile. The previous revision of optical interface standard is named "Variant 1: with fibre core axis oriented towards the connector guide key". The additional optical interface is named "Variant 2: with fibre core axis not oriented towards the connector guide key";
c) statements added related to interoperability, where both variants remain intermateable within a given performance grade and backwards compatible to IEC 61755-3-1:2006;
d) The addition of Grade B and Grade C interface requirements for both variants;
e) The addition of a descriptive statistic for the mean fibre core eccentricity (mean value) to describe the distribution of fibre core eccentricity to ensure interoperability;
f) A new informative Annex B to give guidance on the expected attenuation when mated to a reference connector plug;
g) A new informative Annex C to give guidance related to the simulation of optical interface attenuation;
h) A new informative Annex D to give guidance related to estimation of mean fibre eccentricity limits for finite production batch sizes.

  • Standard
    49 pages
    English and French language
    sale 15% off

IEC 63267-2-2:2024 defines the dimensional limits of an optical interface for reference connections necessary to meet specific requirements for fibre-to-fibre interconnection of non-angled and angled polished multimode reference connectors intended to be used for attenuation measurements in the field or factory. Several grades of reference connections are defined in this document.
The multimode reference connections are terminated to restricted IEC 60793-2-10 A1-OM2b to A1-OM5b fibre at the 850 nm band only.
The geometrical dimensions and tolerances of the specified reference connections have been developed primarily to limit the variation in measured attenuation between multiple sets of two reference connectors, and therefore to limit the variation in measured attenuation between randomly chosen reference connectors when mated with connectors in the field or factory.

  • Standard
    25 pages
    English and French language
    sale 15% off

IEC 63267-2-1:2024 defines a set of specified conditions for an enhanced macro bend of 50/125 µm, graded index multimode fibre optic connection that is maintained in order to satisfy the requirements of attenuation and return loss performance in a randomly mated pair of polished physically contacting (PC) fibres.
An encircled flux (EF) compliant launch condition in accordance with IEC 61300-1, at an operational wavelength of 850 nm, is used for determination of performance grades, based on lateral fibre core offset, numerical aperture (NA) mismatch, and fibre core diameter (CD) variation.
Fibre core angular offset is considered insignificant given the state-of-the-art and is excluded as a factor for attenuation estimation. Attenuation and return loss performance grades are defined in IEC 63267-1.

  • Standard
    64 pages
    English language
    e-Library read for
  • Standard
    25 pages
    English and French language
    sale 15% off

IEC 61753-021-06:2023 defines the minimum initial test and measurement requirements and severities which single-mode fibre optic connectors terminated as a pigtail or a patchcord satisfy in order to be categorised as meeting the IEC standard category OP+ (extended outdoor protected environment), as defined in IEC 61753-1. If tests were performed on the connectors terminated as pigtails or patchcords for category OP+HD and the product passed, the product will be automatically qualified or categorized as meeting the IEC standard for category OP+. If tests are performed on the connectors terminated as pigtails or patchcords for category OP+, and the product passes, the product will be automatically qualified or categorized as meeting the IEC standard for categories OP and C. This first edition cancels and replaces the first edition of IEC 61753-021-6 published in 2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 61753-021-6:2007:
a) updated environmental category (from O to OP+), tests and their severities according to IEC 61753-1:2018;
b) removed the copyright notice as it is no longer needed;
c) changed title and scope to remove restrictions on attenuation and return loss grades;
d) changed the term and definitions of the different types of test samples (pigtail test samples and patchcord test samples) used in the various tests to avoid confusion;
e) removed the term and definition for small form factor (SFF) connectors as it is no longer used in the document;
f) updated fibre naming conventions according to IEC 60793-2-50: and added provisions for B-657 fibres;
g) added all the attenuation and return loss grades defined in IEC 61753-1;
h) removed the static side load test;
i) removed the need to perform all tests sequentially to align with other performance standards;
j) added provisions for rectangular ferrule connectors;
k) added Annex B for visual examination of the outer cable sheath movement of reinforced cables as an additional requirement for change of temperature, cable retention and flexing of the strain relief tests.

  • Standard
    45 pages
    English and French language
    sale 15% off

IEC 61753-021-02:2023 defines the minimum initial test and measurement requirements and severities which single-mode fibre optic connectors terminated as a pigtail or a patchcord satisfy in order to be categorized as meeting the IEC standard category C (controlled environment), as defined in IEC 61753-1. If tests were performed on the connectors terminated as pigtails or patchcords for categories OP+HD, OP+, OP, OPHD, or CHD and the product passed, the product will be automatically qualified or categorized as meeting the IEC standard for category C. This first edition cancels and replaces the second edition of IEC 61753-021-2 published in 2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 61753-021-2:2007:
a) changed scope to remove restrictions on attenuation and return loss grades;
b) included provisions for rectangular ferrule connectors;
c) changed the terms and definitions of the different types of test samples (pigtail test samples and patchcord test samples) used in the various tests to avoid confusion;
d) updated fibre naming conventions according to IEC 60793-2-50 and added provisions for B-657 fibres;
e) added all the attenuation and return loss grades defined in IEC 61753-1;
f) test severities updated according to IEC 61753-1;
g) reduced flexing of strain relief cycles from 100 cycles to 50 cycles;
h) added the torsion test;
i) reduced the duration of the fibre/cable retention test on reinforced cables from 120 s to 60 s minimum;
j) removed the static side load test;
k) reduced the number of mating durability cycles from 500 cycles to 200 cycles and added provisions for rectangular ferrule connectors;
l) added Annex B for visual examination of the outer cable sheath movement of reinforced cables as an additional requirement for change of temperature, cable retention and flexing of the strain relief tests.

  • Standard
    38 pages
    English and French language
    sale 15% off

IEC 63267-1: 2023 covers enhanced macrobend loss 50 µm core diameter multimode fibre optic connection interfaces. It includes references, document structure details, definitions, and standardised optical connection grades. The grades are based on random mated connections between two optical connector populations according to prescribed characteristics including the core diameter and numerical aperture mismatches. This document describes the rules under which an optical interface is created. It also defines standardised test methods where appropriate.

  • Standard
    26 pages
    English and French language
    sale 15% off

IEC TR 62627-01:2023 which is a Technical Report, details cleaning methods for fibre optic connectors. It includes typical cleaning tools and machines, and cleaning procedures. Other cleaning methods exist. The impact of contamination and the reasons for connector visual inspection and cleaning are described in Annex B. This document does not address the visual inspection procedures, which are covered in IEC 61300-3-35. Optical fibre patch cords are handled by the operators and maintenance staff of optical network systems. This document is useful as a guideline to prepare instruction manuals for those involved in optical system maintenance and operation. This document covers fibre optic connector plugs, optical adaptors, optical receptacles (excluding optical transceivers) and dust caps. Guidelines for fibre optic connector end-face cleaning methods for receptacle style optical transceivers are covered in IEC TR 62572-4. This third edition cancels and replaces the second edition published in 2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- addition of cleaning tools for adhesive pad type and adhesive pen type in terms and definitions (Clause 3), in information (7.5 and 7.6), in fibre optic connectors and their applicable cleaning tools (Table 1 and Clause 8) and procedures (9.5, 9.6 and 9.7);
- addition of classification of cleaning tools and machines (Figure 1).

  • Technical report
    26 pages
    English language
    sale 15% off
  • Technical report
    53 pages
    English language
    sale 15% off

IEC 61755-1:2022 covers dispersion unshifted single-mode fibre optic connection interfaces. It includes references, document structure details, definitions, and standardised optical connection grades. The grades are based on random mated connections between two optical connector populations according to required characteristics including fibre mode field diameter (MFD) mismatch. It also defines standardized test methods where appropriate. This second edition cancels and replaces the first edition published in 2005. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- deletion of Figure 2, Figure 3 and Table 4, and consideration of the whole parts of the text;
- addition of the test method for random mating of the multifibre connectors;
- introduction of a nomenclature for the specified core location variants;
- replacement of the limited MFD range, which is now in line with the complete MFD range specified in IEC 60793-2-50;
- replacement of the references to reliability standards to reliability technical reports;
- new general title for the series.

  • Standard
    26 pages
    English and French language
    sale 15% off

IEC 61755-2-2:2022 defines a set of prescribed conditions for a single-mode fibre optic connection that is maintained in order to satisfy the requirements of attenuation and return loss (RL) performance in a randomly mated pair of angled polished physically contacting (APC) fibres. The model uses a Gaussian distribution of light intensity over the specified mode field diameter (MFD) for determination of attenuation performance grades, based on MFD mismatch and the amount of lateral and angular fibre core offsets. Attenuation and RL performance grades are defined in IEC 61755-1. This second edition cancels and replaces the first edition published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- addition of normative references and visual requirements;
- reconsideration of the whole parts of the text to avoid misuse of the standard.

  • Standard
    21 pages
    English and French language
    sale 15% off

IEC 61755-2-1:2022 defines a set of prescribed conditions for a single-mode fibre optic connection that is maintained in order to satisfy the requirements of attenuation and return loss (RL) performance in a randomly mated pair of non-angled polished physically contacting (PC) fibres. The model uses a Gaussian distribution of light intensity over the specified mode field diameter (MFD) for determination of attenuation performance grades, based on MFD mismatch and the amount of lateral and angular fibre core offsets. Attenuation and RL performance grades are defined in IEC 61755-1. This second edition cancels and replaces the first edition published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:  
addition of normative references and visual requirement tables;
reconsideration of the whole parts of the text to avoid misuse of the standard.

  • Standard
    24 pages
    English and French language
    sale 15% off

IEC 61754-20:2012 defines the standard interface dimensions for the type LC family of connectors. The changes with respect to the previous edition are to reconsider the whole document and to add Interface IEC 61754-20-9 to IEC 61754-20-16 for a plastic optical fibre (POF). Keywords: LC connectors

  • Standard
    26 pages
    English language
    sale 15% off
  • Standard
    54 pages
    English and French language
    sale 15% off
  • Standard
    116 pages
    English and French language
    sale 15% off

IEC 61753-131-03:2021 contains the minimum tests, test severities and measurement requirements which a mechanical fibre splice need to satisfy in order to be categorised as meeting the requirements of single-mode fibre splice for use in category OP (Outdoor protected) environments, as defined in IEC 61753-1. This document for mechanical splices defines the requirements for standard optical performance under a set of specified conditions. The standard contains a series or a set of tests and measurements with clearly stated conditions, severities and pass/fail criteria. The series of tests, commonly referred to as an operating service environment or performance category, is intended to be a basis to prove the product’s ability to satisfy the requirements of a specific application, market sector or user group. This first edition cancels and replaces IEC 61753-131-3 first edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) addition of definitions;
b) addition of IEC 60068-2-10 mould growth test and test severities for materials;
c) replacement of the IEC 61753 1:2007 category U tests and test severities by the IEC 61753‑1:2018 category OP tests;
d) addition of the requirement that dimensions are in accordance with IEC 61756-1;
e) addition of the bending moment test;
f) change of low temperature in cold test and change of temperature test to −25°C. If 40°C is required, the user can refer to category OP+.

  • Standard
    34 pages
    English and French language
    sale 15% off

IEC 61753-101-03:2021 contains the minimum tests, test severities and measurement requirements which a fibre management system need to meet in order to be categorised as meeting the IEC standard, category OP – Outdoor Protected environment, as defined in IEC 61753-1. This performance standard for fibre management systems defines the requirements for standard optical performance under a set of specified conditions. It contains a series or a set of tests and measurements with clearly stated conditions, severities and pass/fail criteria. The series of tests, commonly referred to as an operating service environment or performance category, is intended to be a basis to prove the product’s ability to satisfy the requirements of a specific application, market sector or user group.
This first edition cancels and replaces IEC 61753-101-3 the first edition published in 2006. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to IEC 61753-101-3 the previous edition:
a) the terms and definitions have been updated according to IEC 61753-1:2018 and IEC 61756-1:2019;
b) the test severities have been updated according to IEC 61753-1:2018;
c) detailed material tests for mould growth (IEC 60068-2-10) and UV light exposure (ISO 4892-3) have been added;
d) the detailed transport performance requirements have been removed;
e) IEC 60793-2-50 subcategory B-657 fibres for test samples in Annex A has been added.

  • Standard
    47 pages
    English and French language
    sale 15% off

IEC 61753-111-09:2021 contains the minimum tests, test severities and measurement requirements which a sealed fibre optic closure need to meet in order to be categorised as meeting the IEC standard for category S – Subterannean, as defined in Table A.15 of IEC 61753‑1:2018. This first edition cancels and replaces IEC 61753-111-9 published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 61753‑111‑9:  
terms and definitions updated according to IEC 61753-1:2018 and IEC 61756-1:2019;
detailed test severities added for UV light and fungus resistance tests of materials;
test severities updated according to IEC 61753-1:2018;
laboratory test conditions harmonized with IEC 61300-1 to +23 °C ± 5 °C, unless otherwise specified;
addition of B-657 fibre types with minimum bending radius of stored fibres according to IEC 61756-1:2019;
vibration sealing test changed to 10 Hz, 3 mm amplitude and 1 000 000 cycles;
reduced loads added in cable retention test for small diameter cables and tubes;
reduced loads for cable axial compression test for small diameter cables and tubes;
duration of the cycles in torsion and bending test added;
free fall test removed (is covered now by the optical shock test);
assembly and disassembly test duration reduced to 5 cycles
resistance to solvents and contaminating fluids: changed duration of immersion in diesel to 1 h and 24 h drying time and removed immersion in kerosene;
duration of the change of temperature reduced to 12 cycles.

  • Standard
    59 pages
    English and French language
    sale 15% off

IEC 61753-111-07:2021 contains the minimum tests, test severities and measurement requirements which a sealed fibre optic closure need to meet in order to be categorised as meeting the IEC standard for category A – Aerial, as defined in Table A.13 of IEC 61753‑1:2018. Free breathing closures are not covered in this document. This first edition cancels and replaces IEC 61753-111-7 published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 61753‑111‑7:  
terms and definitions updated according to IEC 61753-1:2018 and IEC 61756-1:2019;
detailed test severities added for UV light and fungus resistance tests of materials;
test severities updated according to IEC 61753-1:2018;
test overpressure for sealing tests changed to 20 kPa;
pass-fail criterion of pressure loss during test added to mechanical sealing tests;
laboratory test conditions harmonized with IEC 61300-1 to +23 °C ± 5 °C, unless otherwise specified;
addition of B-657 fibre types with minimum bending radius of stored fibres according to IEC 61756-1:2019;
vibration sealing test changed to 10 Hz, 3 mm amplitude and 1 000 000 cycles;
reduced loads added in cable retention test for small diameter cables and tubes;
reduced loads for cable axial compression test for small diameter cables and tubes;
duration of the cycles in torsion and bending test added;
free fall test removed (is covered now by the optical shock test);
duration of the assembly and disassembly test reduced to 5 cycles;
duration of the change of temperature reduced to 12 cycles.

  • Standard
    57 pages
    English and French language
    sale 15% off

IEC 61753-111-08:2021 contains the minimum tests, test severities and measurement requirements which a sealed fibre optic closure need to meet in order to be categorised as meeting the IEC standard for category G - Ground, as defined in Table A.14 of IEC 61753-1:2018. Free breathing closures are not covered in this document. This first edition cancels and replaces IEC 61753-111-8 published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 61753-111-8:
a) terms and definitions updated according to IEC 61753-1:2018 and IEC 61756-1:2019;
b) test severities updated according to IEC 61753-1:2018;
c) sealing tests are done with 20 kPa overpressure;
d) pass-fail criterion of pressure loss during test added to mechanical sealing tests;
e) vibration sealing test changed to 10 Hz, 3 mm amplitude and 1 000 000 cycles;
f) reduced loads added in cable retention test for small diameter cables and tubes;
g) reduced loads for cable axial compression test for small diameter cables;
h) the duration of the cycles in torsion and bending test is added;
i) free fall test removed (is covered by the optical shock test);
j) crush resistance test of 1 000 N for 10 min is added;
k) assembly and disassembly test: duration reduced to 5 cycles;
l) resistance to solvents and contaminating fluids: added immersion in diesel with duration of 1 h and 24 h drying time and added immersion in petroleum jelly for 5 days;
m) resistance to stress cracking solvents added for 5 days;
n) duration of the change of temperature reduced to 12 cycles;
o) water immersion test at 1 m for 7 days added.

  • Standard
    29 pages
    English language
    sale 15% off
  • Standard
    60 pages
    English and French language
    sale 15% off

IEC 61753-1:2018 provides guidance for the drafting of performance standards for all passive fibre optic products. This document defines the tests and severities which form the performance categories or general operating service environments and identifies those tests which are considered to be product specific. Test and severity details are given in Annex A. This second edition cancels and replaces the first edition published in 2007. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) definitions updated with new products: wall outlets, wall or pole mounted boxes, splices, ODF modules, street cabinets, hardened connectors and field mountable connectors;
b) categories U and O are replaced by categories OP and OP+. No mandatory sequence in category OP+. Category OP+ contains the tests from category OP with the addition of only 4 other tests;
c) addition of Category I (Industrial);
d) temperature ranges added (with the HD suffix to the categories C, OP, OP+ and I) in case passive optical components are placed in a housing together with active electronics (HD stands for “heat dissipation”);
e) the height of category A changed from 3 m to ground level (0 m);
f) the lower level height of category G environment changed from ground level (0 m) to –1 m below ground level. Upper level remains at 3 m above ground level;
g) addition of performance tests, test severities and performance criteria for new products: Wall outlet, wall or pole mounted boxes, mechanical splices, fusion splice protectors, ODF modules, street cabinets, field mountable connectors and hardened optical connectors;
h) test severity of "Mating durability" test for connectors in categories C, OP ,OP+ and I is reduced to 200 cycles for connectors with cylindrical ferrules and 50 cycles for connectors with rectangular ferrules;
i) test severity of "Change of temperature" test for connectors and passive optical components in category I is reduced from 20 cycles to 12 cycles (harmonized with connectors and components from other categories);
j) test severity of "Flexing of strain relief" test for connectors in categories C, OP and OP+ is reduced to 50 cycles;
k) test severities of "Assembly and disassembly of fibre optic mechanical splices, fibre management systems and closures" test for all enclosures is reduced to 5 cycles;
l) test severities of "Change of temperature" test for all protective housings in categories C, A, G and S is reduced from 20 cycles to 12 cycles (harmonized with connectors and components);
m) test severities of "Resistance to solvents and contaminating fluids" test for closures in categories G and S changed – kerosene is removed, diesel oil exposure reduced to 1 h immersion and 24 h drying at room temperature;
n) sealing performance criteria of sealed closures for categories G and A are reduced to 20 kPa overpressure.
o) the change in attenuation criterion for connectors has changed from peak-to-peak into a +/- deviation from the original value of the transmitted power at the start of the test (harmonized with the change in attenuation criterion for components, splices and protective housings).
Keywords: performance standards for all passive fibre optic products
The contents of the corrigendum of May 2019 have been included in this copy.

  • Standard
    118 pages
    English language
    sale 15% off
  • Standard
    209 pages
    English language
    sale 15% off
  • Standard
    242 pages
    English and French language
    sale 15% off
  • Standard
    123 pages
    English and French language
    sale 15% off
  • Standard
    3 pages
    English language
    sale 15% off
  • Standard
    6 pages
    English and French language
    sale 15% off

IEC 61754-35: 2020 defines the standard connector interface dimensions for LSHE family of connectors with up to four termini. This connector family is targeting deployment under harsh environmental conditions.

  • Standard
    33 pages
    English and French language
    sale 15% off

IEC 61756-1:2019 covers general information on fibre management system interfaces. It includes the definitions and rules under which a fibre management system interface is created and it provides also criteria to identify the minimum bending radius for stored fibres. This document allows both single-mode and multimode fibre to be used. Liquid, gas or dust sealing requirements at the cable entry area or cable element ending are not covered in this document. This second edition cancels and replaces the first edition published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- addition of figures to show the interface between protective housing and fibre management system;
- addition of definitions for protective housing, closure, wall box, street cabinets and optical distribution frame modules;
- addition of table with dimensions of fusion splice protectors and mechanical splices;
- addition of method to identify the minimum bending radius for stored fibres;
- addition of clause for other factors relevant to fibre management systems;
- addition of annex A for example of calculating the minimum bending radius of stored fibres in a fibre management system.
Keywords: fibre management system interfaces, minimum bending radius for stored fibres

  • Standard
    62 pages
    English and French language
    sale 15% off

IEC 61754-7-3: 2019 defines the standard interface dimensions for type MPO family of connectors with two rows of 16 fibres.
Keywords: interface dimensions for type MPO connectors

  • Standard
    52 pages
    English and French language
    sale 15% off

IEC 61754-7-2:2017 defines the standard interface dimensions for the type MPO family of connectors with two rows of fibres. This first edition of IEC 61754-7-2, along with the first edition of IEC 61754-7-1, cancels and replaces the third edition of IEC 61754-7 published in 2008. This first edition of IEC 61754-7-2 includes the two fibre row MPO variants including the addition of active device receptacles and up-angled plugs. The first edition of IEC 61754-7-1 includes the one fibre row MPO variants and related active device receptacles and up-angled plugs.
Keywords: interface dimensions for the type MPO family of connectors with two rows of fibres

  • Standard
    36 pages
    English language
    sale 15% off
  • Standard
    73 pages
    English and French language
    sale 15% off

IEC 61755-3-10: 2016 defines certain dimensional limits of a 125 mm diameter single mode silica fibre optical interface and an alignment bore to meet specific requirements for non-angled fibre-to-fibre interconnection as defined in IEC 61755-2-1. The silica fibre materials specified in this document are suitable for use in categories C, U, E and O as defined in IEC 61753-1.

  • Standard
    9 pages
    English language
    sale 15% off
  • Standard
    17 pages
    English and French language
    sale 15% off

IEC TS 62965:2016 which is a Technical Specification, specifies a minimum set of dimensional requirements for fusion splice on connectors (FSOCs) ferrule assemblies and the interface dimensions of splicing tools to ensure that a compliant ferrule assembly is compatible with a compliant fusion splicer. This fusion splicer interface also provides an example of the dimensional requirements for a universal holder, into which an FSOC can be mounted. This fusion splicer interface applies to FSOCs with a cylindrical ferrule of 2,5 mm diameter or 1,25 mm diameter. Keywords: FSOC, fusion splicer interface

  • Technical specification
    22 pages
    English and French language
    sale 15% off

IEC 61754-32:2016 defines the standard interface dimensions for the type DiaLink family of connectors. Keywords: interface dimensions for the type DiaLink family of connectors

  • Standard
    33 pages
    English and French language
    sale 15% off

IEC 61754-34:2016 defines the standard interface dimensions for the type URM family of connectors. Keywords: interface dimensions for type URM connectors

  • Standard
    60 pages
    English and French language
    sale 15% off

IEC 61754-31:2016 defines the standard connector interface dimensions for the two way and four way type N-FO family of connectors. Keywords: standard connector interface dimensions for the two way and four way type N-FO family of connectors

  • Standard
    36 pages
    English and French language
    sale 15% off

IEC TR 62627-01:2016(E) which is a Technical Report, details cleaning methods for fibre optic connectors. It includes typical cleaning tools and machines, and cleaning procedures. Other cleaning methods may exist. The impact of contamination and the reasons for connector visual inspection and cleaning are described in Annex B. This Technical Report does not address the visual inspection criteria, which are covered in IEC 61300-3-35:2015. Optical fibre patch cords are handled by the operators and maintenance staff of optical network systems. This Technical Report may be used as a guideline to prepare instruction manuals for those involved in optical system maintenance and operation. This Technical Report covers fibre optic connector plugs, optical adaptors, optical receptacles (excluding optical transceivers) and dust caps. Guidelines for optical connector end-face cleaning methods for receptacle style optical transceivers are covered in IEC TR 62572-4. This second edition cancels and replaces the first edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- restructure of clauses;
- addition of some terms and definitions;
- addition of information on cleaning tools and machines;
- addition of information on dust caps;
- addition of applicable cleaning tools and machines for optical connectors.
Keywords: fibre optic connectors, optical system maintenance and operation

  • Technical report
    23 pages
    English language
    sale 15% off

IEC 61754-6-100:2015 defines the standard interface dimensions of simplified receptacle dimensions for the type MU connector family. The receptacle assembly consists of a simplified receptacle housing and a simplified plug. Keywords: interface dimensions for the type MU connector

  • Standard
    25 pages
    English and French language
    sale 15% off

IEC 61754-4-100:2015 specifies the standard simplified receptacle interface dimensions for the type SC connector family. The receptacle assembly consists of a simplified receptacle housing and a simplified plug. Keywords: interface dimensions for the type SC connector

  • Standard
    25 pages
    English and French language
    sale 15% off

IEC 61755-3-31:2015 defines certain dimensional limits of an angled PC rectangular polyphenylene sulphide (PPS) ferrule optical interface in order to meet specific requirements for fibre-to-fibre interconnection. Ferrules made from the material specified in this standard are suitable for use in categories C, U, E, and O as defined in IEC 61753-1. Ferrule interface dimensions and features are contained in the IEC 61754 series, which deals with fibre optic connector interfaces. Keywords: dimensional limits of an angled PC rectangular polyphenylene sulphide (PPS) ferrule optical interface, fibre-to-fibre interconnection

  • Standard
    50 pages
    English and French language
    sale 15% off

IEC 61755-2-4:2015 defines a set of prescribed conditions that should be maintained in order to satisfy the requirements of non-angled polished reference connections. The prescribed conditions include dimensional limits and optical fibre requirements of the optical interface to meet specific requirements for reference connection (plugs and adaptors) used for attenuation measurements. Two different grades for reference connections are defined in this standard. The use of each of these grades depends on the application and on the targeted attenuation measurement uncertainty. The model uses a Gaussian distribution of light intensity over the specified restricted mode field diameter (MFD) range. This standard is intended to be used for shipping and acceptance inspections. The reference connector plug is specified for B1.1, B1.3 and B6 fibres as specified in IEC 60793-2-50. The use of the reference connector plug would not be recommended where classification of fibre is difficult, for example construction and maintenance of cable plant. Keywords: non-angled polished reference connections, plugs and adaptors, attenuation measurements

  • Standard
    10 pages
    English language
    sale 15% off
  • Standard
    21 pages
    English and French language
    sale 15% off

IEC 61755-2-5:2015 defines a set of prescribed conditions that should be maintained in order to satisfy the requirements of angled polished reference connections. The prescribed conditions include dimensional limits and optical fibre requirements of the optical interface to meet specific requirements for reference connection (plugs and adaptors) used for attenuation measurements. Two different grades for reference connections are defined in this standard. The use of each of these grades depends on the application and on the targeted attenuation measurement uncertainty. The model uses a Gaussian distribution of light intensity over the specified restricted mode field diameter (MFD) range. This standard is intended to be used for shipping and acceptance inspections. The reference connector plug is specified for B1.1, B1.3 and B6 fibres as specified in IEC 60793-2-50. The use of the reference connector plug would not be recommended where classification of fibre is difficult, for example construction and maintenance of cable plant. Keywords: angled polished reference connections, plugs and adaptors, attenuation measurements

  • Standard
    10 pages
    English language
    sale 15% off
  • Standard
    21 pages
    English and French language
    sale 15% off

IEC 61754-7-1:2014 defines the standard interface dimensions for type MPO family of connectors with one row of fibres. This first edition of IEC 61754-7-1, along with the first edition of IEC 61754-7-2, cancels and replaces the third edition of IEC 61754-7, published in 2008. This first edition of IEC 61754-7-1 includes the one fibre row MPO variants, including the addition of active device receptacles and up-angled plugs. Keywords: interface dimensions for type MPO family of connectors with one row of fibres

  • Standard
    31 pages
    English language
    sale 15% off
  • Standard
    63 pages
    English and French language
    sale 15% off

Frequently Asked Questions

WG 6 is a Technical Committee within the International Electrotechnical Commission (IEC). It is named "Standards and specifications for fibre optic interconnecting devices and related components" and is responsible for: To prepare and maintain standards and specifications for fibre optic interconnecting devices and related components such as connectors, splices splice closures, etc. This committee has published 670 standards.

WG 6 develops IEC standards in the area of Information technology. The scope of work includes: To prepare and maintain standards and specifications for fibre optic interconnecting devices and related components such as connectors, splices splice closures, etc. Currently, there are 670 published standards from this technical committee.

The International Electrotechnical Commission (IEC) is the world's leading organization for the preparation and publication of international standards for electrical, electronic, and related technologies. Founded in 1906, the IEC provides a global platform for companies, industries, and governments to meet, discuss, and develop the international standards they require.

A Technical Committee (TC) in IEC is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.