WG 2 - TC 77/SC 77A/WG 2
TC 77/SC 77A/WG 2
General Information
The contents of the corrigendum of January 2022 have been included in this copy.
- Standard7 pagesEnglish languagesale 15% off
- Standard13 pagesEnglish and French languagesale 15% off
This amendment 1 is valid for the following parts of the IEC 60317: Part 2 (1990), Part 3 (1990), Part 4 (1990), Part 10 (1972), Part 12 (1990), Part 14 (1990), Part 15 (1990), Part 16 (1990), Part 17 (1990), Part 18 (1990), Part 19 (1990), Part 20 (1990), Part 21 (1990), Part 22 (1990), Part 23 (1990), Part 24 (1990), Part 26 (1990), Part 28 (1990), Part 29 (1990), Part 30 (1990), Part 35 (1992), Part 36 (1992), Part 37 (1992) and Part 38 (1992).
- Standard5 pagesEnglish and French languagesale 15% off
IEC 61000-3-11:2017 is also available as IEC 61000-3-11:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61000-3-11:2017 is concerned with the emission of voltage changes, voltage fluctuations and flicker produced by equipment and impressed on the public low-voltage supply system. It specifies the limits of voltage changes produced by equipment tested under specified conditions.
This edition includes the following significant technical changes with respect to the previous edition:
a) addition of a new Annex A which explains the limitations and effectiveness of IEC 61000‑3-11 regarding the connection of multiple items of similar equipment at the same location in the supply network.
- Standard38 pagesEnglish and French languagesale 15% off
IEC TR 61000-4-38:2015(E) defines a test protocol for flicker test systems designed to perform compliance tests in accordance with IEC 61000-3-3 and IEC 61000-3-11. It is intended to provide test system manufacturers and testing laboratories with systematic methods to determine if the flicker test system meets the IEC design specifications for a wide range of voltage fluctuations and fluctuation frequencies, as specified in IEC 61000-4-15:2010, Table 5, that have been observed in product testing. It has the status of a basic EMC publication in accordance with IEC Guide 107.
- Technical report25 pagesEnglish languagesale 15% off
IEC 61000-3-3:2013 is available as IEC 61000-3-3:2013 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61000-3-3:2013 is concerned with the limitation of voltage fluctuations and flicker impressed on the public low-voltage system. It specifies limits of voltage changes which may be produced by an equipment tested under specified conditions and gives guidance on methods of assessment. It is applicable to electrical and electronic equipment having an input current equal to or less than 16 A per phase, intended to be connected to public low-voltage distribution systems of between 220 V and 250 V line to neutral at 50 Hz, and not subject to conditional connection. IEC 61000-3-3 has the status of a product family standard within the IEC 61000 series. This third edition cancels and replaces the second edition published in 2008. This edition constitutes a technical revision which takes account of the changes made in IEC 61000-4-15:2010.
- Standard72 pagesEnglish languagesale 15% off
- Standard148 pagesEnglish and French languagesale 15% off
- Standard69 pagesEnglish and French languagesale 15% off
IEC/TR 60725:2012, which is a technical report, records the information that was available and the factors that were taken into account in arriving at the reference impedances that were incorporated in IEC 60555 and which are now incorporated in some parts of IEC 61000-3. In addition, information is given on the impedances of public supply networks associated with service current capacities ≤100 A per phase. The third edition includes brings two mainly significant technical changes with respect to the previous edition:
- a new survey and other data from countries with public supply networks operating at 60 Hz have been included; and
- recommendations that were applicable to 50 Hz systems are now mirrored by new recommendations that are relevant to 60 Hz systems.
- Technical report58 pagesEnglish and French languagesale 15% off
IEC 61000-4-15:2010 is available as IEC 61000-4-15:2010 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61000-4-15:2010 gives a functional and design specification for flicker measuring apparatus intended to indicate the correct flicker perception level for all practical voltage fluctuation waveforms. Information is presented to enable such an instrument to be constructed. A method is given for the evaluation of flicker severity on the basis of the output of flickermeters complying with this standard. The flickermeter specifications in this part of IEC 61000 relate only to measurements of 120 V and 230 V, 50 Hz and 60 Hz inputs. Characteristics of some incandescent lamps for other voltages are sufficiently similar to the values in Table 1 and Table 2, that the use of a correction factor can be applied for those other voltages. Some of these correction factors are provided in the Annex B. Detailed specifications for voltages and frequencies other than those given above, remain under consideration. The object of this part of IEC 61000 is to provide basic information for the design and the instrumentation of an analogue or digital flicker measuring apparatus. It does not give tolerance limit values of flicker severity. This second edition cancels and replaces the first edition published in 1997 and its Amendment 1 (2003) and constitutes a technical revision. This new edition, in particular, adds or clarifies the definition of several directly measured parameters, so that diverging interpretations are avoided. It has the status of a basic EMC publication in accordance with IEC Guide 107.
The contents of the corrigendum of March 2012 have been included in this copy.
- Standard83 pagesEnglish and French languagesale 15% off
IEC/TS 61000-3-5:2009 deals with emission of disturbances due to voltage fluctuations and flicker. The recommendations in this Technical Specification are applicable to electrical and electronic equipment that has a rated input current exceeding 75 A per phase and is intended to be connected to a public low-voltage a.c. distribution system. Recommendations that specify information enabling a supply authority, manufacturer, or consumer to assess equipment are given in Annex A. This second edition cancels and replaces IEC 61000-3-5, published as Technical Report type 2 in 1994 and constitutes a technical revision. It includes the following significant technical changes with respect to the previous edition: the whole document and the title have been modified to eliminate any conflict with the published IEC 61000-3-11. The contents of the corrigenda of September 2009 and May 2010 have been included in this copy.
- Technical specification21 pagesEnglish and French languagesale 15% off