MT 4 - TC 23/SC 23B/MT 4
TC 23/SC 23B/MT 4
General Information
IEC 60884-2-1:2025 applies to fused plugs, where the fuses are primarily intended to protect the flexible cable connected to the plug. These fuses are not intended to protect appliances or parts of them against overload.
This third edition cancels and replaces the second edition published in 2006. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment to IEC 60884‑1, fourth edition.
- Standard21 pagesEnglish languagesale 15% off
IEC 60884-2-7:2025 applies to cord extension sets, rewirable and non-rewirable, with or without earthing contact, with a rated voltage greater than 50 V but not exceeding 440 V and a rated current not exceeding 16 A, intended for household and similar purposes, either indoors or outdoors. This document does not apply to cord extension sets with means for reeling. Cord extension sets intended to be used as socket-outlets for furniture are additionally covered by IEC 60884‑2‑8. This document also applies to cord extension sets which are intended to be used in a cable reel, and which therefore become cable reels with a detachable flexible cable. For the combination of the cord extension set, the reel requirements and tests of IEC 61242 apply in addition.
Cord extension sets are suitable for use at ambient temperatures not normally exceeding +40 °C, but their average temperature over a period of 24 h does not exceed +35 °C, with a lower limit of the ambient air temperature of −5 °C.
This second edition cancels and replaces the first edition published in 2011, and Amendment 1:2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment to IEC 60884-1, fourth edition.
- Standard40 pagesEnglish languagesale 15% off
IEC 60884-2-6:2025 applies to switched socket-outlets with interlock for AC only, for fixed electrical installations, with or without earthing contact, with rated voltage above 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors. Switched socket-outlets with interlock according to this document consist of a combination of socket-outlets according to IEC 60884‑1, interlocked with a switch according to IEC 60669‑1 and/or IEC 60669‑2‑1 supplied as a complete accessory. The rated current is limited to 16 A maximum for fixed accessories provided with screwless terminals.
This document does not cover requirements for flush mounting boxes. However, it covers those requirements for surface-type mounting boxes which are necessary for the tests on socket-outlets.
This second edition cancels and replaces the first edition published in 1997. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment to IEC 60884-1, fourth edition.
- Standard34 pagesEnglish languagesale 15% off
IEC 60884-2-3:2025 applies to switched socket-outlets without interlock, for fixed installation, for AC only, with or without earthing contact, with a rated voltage not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors. This document applies to socket-outlets controlled by a manually operated mechanical switch.
This third edition cancels and replaces the second edition published in 2006. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment to IEC 60884-1, fourth edition.
- Standard35 pagesEnglish languagesale 15% off
IEC 60884-2-2:2025 applies to socket-outlets for AC only, with or without earthing contact, with a rated voltage not exceeding 250 V and a rated current not exceeding 16 A, which are integrated or intended to be incorporated in or fixed to appliances, hereafter referred to as socket-outlets for appliances. This third edition cancels and replaces the second edition published in 2006. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment to IEC 60884‑1 fourth edition.
- Standard28 pagesEnglish languagesale 15% off
IEC 60669-2-4:2024 applies to manually operated general purpose isolating switches with a rated voltage not exceeding 440 V and a rated current not exceeding 125 A, intended for household and similar fixed electrical installations, either indoors or outdoors. This second edition cancels and replaces the first edition published in 2004. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) revision of the present edition with reference to the published IEC 60669-1:2017 Edition 4 with its amendments and references to clauses and tables;
b) introducing the values for isolating switches with ratings from 6 A to 13 A;
c) introducing a circuit motor load with a rated current not exceeding 10 A and a power factor not less than 0,6 in the scope;
d) modification of Table 1 and Table 5.
- Standard209 pagesEnglish languagesale 15% off
- Standard70 pagesEnglish and French languagesale 15% off
IEC 60884-1:2022 applies to plugs and fixed or portable socket-outlets for AC only, with or without earthing contact, with a rated voltage greater than 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors.
Compatible plugs and socket-outlets, when combined, form a plug and socket-outlet system. Standardized systems used around the world are reported in IEC/TR 60083.
The rated current is limited to 16 A maximum for accessories provided with screwless-type terminals.
This fourth edition cancels and replaces the third edition published in 2002, Amendment 1:2006 and Amendment 2:2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
plugs and socket-outlets incorporating pilot lights;
crimped connections in accessories;
insulation piercing terminals (IPT);
accessories to be used with American Wire Gauge (AWG) cables;
accessories used in T° below −5 °C down to and including −45 °C;
accessories used in T° above +40 °C up to and including +70 °C;
plugs and socket-outlets for high load (HL);
clarification of some definitions;
durability of markings test;
introduction of thermal monitoring in the plug;
requirements for shutters in portable socket-outlets;
test walls for the verification of ingress of water;
rewriting of the temperature rise clause.
- Standard7 pagesEnglish and French languagesale 15% off
IEC 60884-1:2022 applies to plugs and fixed or portable socket-outlets for AC only, with or without earthing contact, with a rated voltage greater than 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors.
Compatible plugs and socket-outlets, when combined, form a plug and socket-outlet system. Standardized systems used around the world are reported in IEC/TR 60083.
The rated current is limited to 16 A maximum for accessories provided with screwless-type terminals.
This fourth edition cancels and replaces the third edition published in 2002, Amendment 1:2006 and Amendment 2:2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
plugs and socket-outlets incorporating pilot lights;
crimped connections in accessories;
insulation piercing terminals (IPT);
accessories to be used with American Wire Gauge (AWG) cables;
accessories used in T° below −5 °C down to and including −45 °C;
accessories used in T° above +40 °C up to and including +70 °C;
plugs and socket-outlets for high load (HL);
clarification of some definitions;
durability of markings test;
introduction of thermal monitoring in the plug;
requirements for shutters in portable socket-outlets;
test walls for the verification of ingress of water;
rewriting of the temperature rise clause.
The contents of the corrigendum of November 2023 have been included in this copy.
- Standard196 pagesEnglish languagesale 15% off
- Standard410 pagesEnglish and French languagesale 15% off
- Standard2 pagesEnglish and French languagesale 15% off
IEC 60669-1:2017 applies to manually operated general purpose functional switches, for alternating current (AC) only with a rated voltage not exceeding 440 V with a rated current not exceeding 63 A, intended for household and similar fixed electrical installations, either indoors or outdoors. For switches provided with screwless terminals, the rated current is limited to 16 A. This fourth edition cancels and replaces the third edition published in 1998, Amendment 1:1999 and Amendment 2:2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) change of the scope for motor load switches;
b) deletion of some dated normative references;
c) changes to the definitions;
d) in Clause 5 the number of specimens to be used for the tests are clearly given in Table 1 (Corresponding Annex A of IEC 60669-1:1998 was therefore deleted);
e) in Clause 5 it was clarified on which switches the tests of Clause 19 shall be carried out;
f) requirements concerning 13 A switches have been included;
g) mandatory indication that a terminal is suitable for rigid conductor only;
h) requirements and test conditions for flexible conductors have been included in Clause 12;
i) requirements for pilot light units have been included;
j) new test for self-ballasted lamp loads in 19.3;
k) Table 20 has been completely redrawn to cover normal, mini and micro-gap switches and renumbered Table 21;
l) new informative Annex B including changes planned for the future in order to align IEC 60669-1 with the requirements of IEC 60998 (all parts), IEC 60999 (all parts) and IEC 60228;
m) new informative Annex C about the circuit development for 19.3;
n) new informative Annex D including additional requirements for insulation-piercing terminals;
o) new informative Annex E including additional requirements and tests for switches intended to be used at a temperature lower than -5 °C.
The contents of the corrigendum of January 2020 have been included in this copy.
- Standard445 pagesEnglish languagesale 15% off
- Standard289 pagesEnglish and French languagesale 15% off
The contents of the corrigendum of March 2014 have been included in this copy.
- Standard8 pagesEnglish and French languagesale 15% off
- Standard118 pagesEnglish and French languagesale 15% off
IEC 60884-2-7:2011 applies to cord extension sets, rewirable and non rewirable, with or without earthing contact, with a rated voltage greater than 50 V but not exceeding 440 V and a rated current not exceeding 16 A, intended for household and similar purposes, either indoors or outdoors.
This publication is to be read in conjunction with IEC 60884-1:2002.
- Standard25 pagesEnglish and French languagesale 15% off
- Standard26 pagesEnglish and French languagesale 15% off
Applies to manually operated general purpose switches for a.c. only, with a rated voltage not exceeding 440 V and a rated current not exceeding 63 A.
- Standard94 pagesEnglish languagesale 15% off
- Standard94 pagesEnglish languagesale 15% off
- Standard94 pagesFrench languagesale 15% off
- Standard94 pagesFrench languagesale 15% off
- Standard181 pagesEnglish and French languagesale 15% off
- Standard187 pagesEnglish and French languagesale 15% off
- Standard189 pagesEnglish and French languagesale 15% off
This part of IEC 60884 applies to socket-outlets for a.c. only, with or without earthing contact, with a rated voltage not exceeding 250 V and a rated current not exceeding 16 A, which are integrated or intended to be incorporated in or fixed to appliances, hereafter referred to as socket-outlets for appliances.
- Standard11 pagesEnglish languagesale 15% off
- Standard11 pagesFrench languagesale 15% off
- Standard21 pagesEnglish and French languagesale 15% off
This part of IEC 60884 applies to fused plugs, where the fuses are primarily intended to protect the flexible cable or cord. These fuses are not intended to protect appliances or parts of them against overload.
- Standard9 pagesEnglish languagesale 15% off
- Standard9 pagesFrench languagesale 15% off
- Standard17 pagesEnglish and French languagesale 15% off
This part of IEC 60884 applies to switched socket-outlets without interlock, for fixed installation, for a.c. only, with or without earthing contact, with a rated voltage not exceeding 440 V and a rated current not exceeding 32A, intended for household and similar purposes, either indoors or outdoors.
- Standard29 pagesEnglish and French languagesale 15% off
- Standard18 pagesEnglish languagesale 15% off
- Standard18 pagesFrench languagesale 15% off
- Standard35 pagesEnglish and French languagesale 15% off
The object of this technical report is to give general information about the systems of plugs and socket-outlets for household and similar purposes which are used in the IEC countries. The report only contains National Systems which are commonly used in homes and offices. It is therefore limited to systems for a.c. with a rated voltage above 50 V but not exceeding 440 V, intended for household and similar purposes, either indoors or outdoors. The report only contains systems for which standard sheets have been published in a National Standard, which may be a National Standard of the country itself or any other IEC member country
- Technical report186 pagesEnglish languagesale 15% off
- Technical report186 pagesFrench languagesale 15% off
- Technical report369 pagesEnglish and French languagesale 15% off
This part of IEC 60669 applies to manually operated general purpose isolating switches with a rated voltage not exceeding 440 V and a rated current not exceeding 125 A, intended for household and similar fixed electrical installations, either indoors or outdoors.
- Standard69 pagesEnglish and French languagesale 15% off
Applies to plugs and fixed or portable socket-outlets for a.c. only, with and without earthing contact, with a rated voltage above 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar proposes, either, indoors or outdoors.
- Standard133 pagesEnglish languagesale 15% off
- Standard133 pagesFrench languagesale 15% off
- Standard247 pagesEnglish and French languagesale 15% off
- Standard265 pagesEnglish and French languagesale 15% off
- Standard327 pagesEnglish and French languagesale 15% off
- Standard27 pagesEnglish and French languagesale 15% off
Applies to switched socket-outlets with interlock for a.c. only, for fixed electrical installations, with or without earthing contact, with rated voltage above 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors.
- Standard27 pagesEnglish and French languagesale 15% off