General Information

Abstract

IEC 61169-39:2009 is a sectional specification. It provides information and rules for the preparation of detail specifications for CQM series quick lock RF connectors together with the pro forma blank detail specification (DS). It also prescribes mating interface dimensions for general purpose connectors, dimensional details of standard test connectors grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to CQM series connectors. This specification indicates the recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H. The French version of this standard has not been voted upon. This bilingual version, published in 2011-04, corresponds to the English version.

Status
Published
Publication Date
15-Jun-2009
Current Stage
PPUB - Publication issued
Start Date
16-Jun-2009
Completion Date
30-Sep-2009

Buy Documents

Standard

IEC 61169-39:2009 - Radio-frequency connectors - Part 39: Sectional specification for CQM series quick lock RF connectors Released:6/16/2009

ISBN:978-2-88910-431-4
English language (26 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

IEC 61169-39:2009 - Radio-frequency connectors - Part 39: Sectional specification for CQM series quick lock RF connectors Released:6/16/2009

ISBN:978-2-88912-392-6
English and French language (53 pages)
sale 15% off
Preview
sale 15% off
Preview

Overview

IEC 61169-39:2009 is a sectional specification from the International Electrotechnical Commission (IEC) for the CQM series quick‑lock RF connectors. It defines the rules and pro‑forma blank detail specification (DS) used to prepare vendor and product detail specifications for CQM connectors. The standard targets 50 Ω quick‑lock connectors intended for high‑power microwave applications (operating frequency limit at least 4 GHz) used with RF cables and microstrips.

Key Topics

  • Detail specification guidance: Rules and a blank DS (pro forma) to standardize how manufacturers document CQM connector variants.
  • Mating interface dimensions: Prescribed dimensional data for general‑purpose connectors (Grade 2) and for standard test connectors (Grade 0), supported by figures and tables for reproducible mating and interchangeability.
  • Gauging information: Definitions and test sequences for gauges (outer contact and centre contact pins) used to size and verify contacts and retention forces.
  • Quality assessment and tests: Selected tests and measuring methods drawn from IEC 61169-1, including acceptance and periodic test schedules and inspection requirements for assessment levels M and H.
  • Performance and inspection requirements: Recommended performance characteristics, test severities and inspection procedures to be referenced when writing detail specifications.
  • Supplementary material: Illustrative figures and dimensional tables for connectors, gauges and standard test connectors to support manufacturing and test processes.

Applications

IEC 61169-39 is practical for organizations that design, manufacture, test, procure or validate RF connectors:

  • Connector manufacturers - to prepare compliant detail specifications, set production tolerances, and demonstrate interchangeability.
  • Test laboratories and quality engineers - to apply prescribed gauges, acceptance/periodic tests and quality conformance inspection procedures.
  • System integrators and RF designers - to ensure connector choices meet mechanical and electrical mating interface requirements for 50 Ω, up to ≥4 GHz applications.
  • Procurement and certification teams - to include standardized DS references in purchase orders and qualification procedures.

Using this standard helps ensure mechanical interchangeability, consistent performance characteristics, and repeatable test/inspection regimes for CQM series quick‑lock RF connectors.

Related Standards

  • IEC 61169-1 - Radio‑frequency connectors: Generic specification (general requirements and measuring methods). IEC 61169-39 references tests and procedures from this part.
  • Other parts of the IEC 61169 series address additional RF connector families and generic test methods; consult the IEC catalogue for related parts.

Relations

Effective Date
05-Sep-2023

Buy Documents

Standard

IEC 61169-39:2009 - Radio-frequency connectors - Part 39: Sectional specification for CQM series quick lock RF connectors Released:6/16/2009

ISBN:978-2-88910-431-4
English language (26 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

IEC 61169-39:2009 - Radio-frequency connectors - Part 39: Sectional specification for CQM series quick lock RF connectors Released:6/16/2009

ISBN:978-2-88912-392-6
English and French language (53 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

IEC 61169-39:2009 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Radio-frequency connectors - Part 39: Sectional specification for CQM series quick lock RF connectors". This standard covers: IEC 61169-39:2009 is a sectional specification. It provides information and rules for the preparation of detail specifications for CQM series quick lock RF connectors together with the pro forma blank detail specification (DS). It also prescribes mating interface dimensions for general purpose connectors, dimensional details of standard test connectors grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to CQM series connectors. This specification indicates the recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H. The French version of this standard has not been voted upon. This bilingual version, published in 2011-04, corresponds to the English version.

IEC 61169-39:2009 is a sectional specification. It provides information and rules for the preparation of detail specifications for CQM series quick lock RF connectors together with the pro forma blank detail specification (DS). It also prescribes mating interface dimensions for general purpose connectors, dimensional details of standard test connectors grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to CQM series connectors. This specification indicates the recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H. The French version of this standard has not been voted upon. This bilingual version, published in 2011-04, corresponds to the English version.

IEC 61169-39:2009 is classified under the following ICS (International Classification for Standards) categories: 31.140 - Piezoelectric devices; 33.120.30 - RF connectors. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 61169-39:2009 has the following relationships with other standards: It is inter standard links to IEC PAS 61169-39:2008. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

IEC 61169-39:2009 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


IEC 61169-39 ®
Edition 1.0 2009-06
INTERNATIONAL
STANDARD
Radio-frequency connectors –
Part 39: Sectional specification for CQM series quick lock RF connectors

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.

IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: 0Hinmail@iec.ch
Web: 1Hwww.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: 2Hwww.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: 3Hwww.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Electropedia: 4Hwww.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
ƒ Customer Service Centre: 5Hwww.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: 6Hcsc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 61169-39 ®
Edition 1.0 2009-06
INTERNATIONAL
STANDARD
Radio-frequency connectors –
Part 39: Sectional specification for CQM series quick lock RF connectors

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
U
ICS 33.120.30 ISBN 978-2-88910-431-4
– 2 – 61169-39 © IEC:2009(E)
CONTENTS
FOREWORD.0H4
1 Scope.1H6
2 Normative references .2H6
3 Mating interface and gauge information .3H6
3.1 Dimensions-General connectors – Grade 2 .4H7
3.1.1 Connector with pin-centre contact.5H7
3.1.2 Connectors with socket-centre contact .6H8
3.2 Gauges .7H9
3.2.1 Connectors with socket-centre contact .8H9
3.3 Dimensions – standard test connectors – Grade 0.9H11
3.3.1 Connector with pin-centre contact.10H11
3.3.2 Connector with socket-centre contact .11H13
4 Quality assessment procedure.12H14
4.1 General .13H14
4.2 Rating and characteristics (see Clause 6 of IEC 61169-1) .14H14
4.3 Test schedule and inspection requirements .15H17
4.3.1 Acceptance tests .16H17
4.3.2 Periodic tests .17H18
4.4 Procedures.18H19
4.4.1 Quality conformance inspection .19H19
4.4.2 Qualification approval and its maintenance.20H19
5 Instructions for preparation of detail specifications .21H19
5.1 General .22H19
5.2 Identification of the detail specification .23H20
5.3 Identification of the component.24H20
5.4 Performance.25H20
5.5 Marking, ordering information and related matters .26H20
5.6 Selection of tests, test conditions and severities.27H20
5.7 Blank detail specification pro-forma for type CQM connector .28H21
Bibliography.29H26

Figure 1 – Connector with pin-centre contact (for dimensions, see Table 1).30H7
Figure 2 – Connector with socket-centre contact (for dimensions, see Table 2) .31H8
Figure 3 – Gauge for outer contact of socket connector (for dimensions, see Table 3) .32H9
Figure 4 – Gauge pin for socket contact (for dimensions, see Table 4) .33H9
Figure 5 – Connector of pin-centre contact (for dimensions, see Table 5).34H11
Figure 6 – Standard test connector with socket-centre contact (for dimensions, see
Table 6) .35H13

Table 1 – Dimensions of connector with pin-centre contact .36H7
Table 2 – Dimensions of connector with socket-centre contact.37H8
Table 3 – Dimensions of gauge for outer contact of socket connector .38H9
Table 4 – Dimensions of gauge pin for socket contact.39H10
Table 5 – Dimensions of connector with pin-centre contact .40H12

61169-39 © IEC:2009(E) – 3 –
Table 6 – Dimensions of standard test connector with socket-centre contact .41H14
Table 7 – Ratings and characteristics .42H15
Table 8 – Acceptance tests.43H17
Table 9 – Periodic tests .44H18

– 4 – 61169-39 © IEC:2009(E)
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO-FREQUENCY CONNECTORS –
Part 39: Sectional specification for CQM
series quick lock RF connectors

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61169-39 has been prepared by subcommittee 46F: RF and
microwave passive components, of IEC technical committee 46: Cables, wires, waveguides,
R.F. connectors, R.F. and microwave passive components and accessories.
The text of this standard is based on the following documents:
CDV Report on voting
46F/107/CDV 46F/133/RVC
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

61169-39 © IEC:2009(E) – 5 –
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
A list of all parts of the IEC 61169 series can be found, under the general title Radio-
frequency connectors, on the IEC website.
A bilingual version of this publication may be issued at a later date.

– 6 – 61169-39 © IEC:2009(E)
RADIO-FREQUENCY CONNECTORS –
Part 39: Sectional specification for CQM
series quick lock RF connectors

1 Scope
CQM series quick lock connectors with characteristic impedance 50 Ω are used for high
power microwave applications, connecting with RF cables or microstrips. The operating
frequency limit is at least 4 GHz.
This sectional specification provides information and rules for the preparation of detail
specifications for CQM series quick lock RF connectors together with the pro forma blank
detail specification (DS).
It also prescribes mating interface dimensions for general purpose connectors, dimensional
details of standard test connectors grade 0, gauging information and tests selected from
IEC 61169-1, applicable to all detail specifications relating to CQM series connectors.
This specification indicates the recommended performance characteristics to be considered
when writing a detail specification and it covers test schedules and inspection requirements
for assessment levels M and H.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 61169-1:1992, Radio-frequency connectors – Part 1: Generic specification – General
requirements and measuring methods
3 Mating interface and gauge information
All undimensioned pictorial configurations are for reference purposes only.

61169-39 © IEC:2009(E) – 7 –
3.1 Dimensions-General connectors – Grade 2
3.1.1 Connector with pin-centre contact

m
Note 4 Note 1
n
p
u k
l
a b c d e f g s v t
+0,1 i
R1,5
Note 2 Note 3
j
h
IEC  993/09
Figure 1 – Connector with pin-centre contact (for dimensions, see Table 1)
Table 1 – Dimensions of connector with pin-centre contact
Reference mm Note
min max
a 5,96 6,04 Diameter
b 7(nominal) Diameter
c 15,85 16,25 Diameter
d 16,90 17,10 Diameter
e 18,00 18,20 Diameter
f 21,00 21,20 Diameter
g 21,90 22,10 Diameter
h 8,90 9,20
i 3,70 3,90
j 4,30 4,50
k - 9,80
l 0,30 0,50
m 8,80 9,00
n 7,20 7,40
p 4,20 4,40
s 23,20 23,30 Diameter
t 35,00 35,20 Diameter
u 2,10 2,30
v 26,9 27,2 Diameter
NOTE 1 Mechanical reference plane.
NOTE 2 The spring force is 50 N to 60 N max.
NOTE 3 Tolerances of dimensions are to meet the requirements of characteristic impedances.
NOTE 4 Ring.
– 8 – 61169-39 © IEC:2009(E)
3.1.2 Connectors with socket-centre contact

Note 3
Note 5
g
h
Note 6 i f
u
Note 4
j
Note 2
Note 1
n m e c a
d b
1,5 × 45° s
r
p
k
q
l
IEC  994/09
Figure 2 – Connector with socket-centre contact (for dimensions, see Table 2)
Table 2 – Dimensions of connector with socket-centre contact
Reference mm Note
min max
a 7(nominal) Diameter (Note 1)
b 15,85 16,25 Diameter
c 16,70 16,90 Diameter
d 17,80 18,00 Diameter
e 22,10 22,30 Diameter
f 6,30 6,50
g 9,10 9,30
h 12,75 12,85
i 0,20 0,40
j -- 0,20
k 7,00 7,50
l 8,50 9,00
m 23,60 23,80 Diameter
n 35,20 35,40 Diameter
p 0,80 1,00
q 1,10 1,30
r 1,60 --
s 2,60 --
u 4,90 5,20
NOTE 1 Design for slotting optional, closed contacts should meet electrical and mechanical requirements.
NOTE 2 Design for slotting optional, flared contacts Ød should be flared to Ø18,4~Ø18,5.
NOTE 3 Mechanical reference plane.
NOTE 4 Three steel balls, Ø3.
NOTE 5 The spring force is 2 N to 6 N, movement is 1,60 mm min.
NOTE 6 Ring.
61169-39 © IEC:2009(E) – 9 –
3.2 Gauges
3.2.1 Connectors with socket-centre contact
3.2.1.1 Gauge for outer contact of socket connector

v
w
s t u
IEC  995/09
Figure 3 – Gauge for outer contact of socket connector (for dimensions, see Table 3)
Table 3 – Dimensions of gauge for outer contact of socket connector
Gauge A Gauge B Note
(for sizing purposes) (for measurement of gauge retention force for outer
conductor)
Mass (weight) of gauge: 200 g ± 5 g
Ref. mm mm
min max min max
s 18,05 18,10 18,15 18,18
t 18,70 18,80 18,70 18,80
u 20,00 20,80 20,00 20,80
v 9,50 9,60 9,40 9,50
w 1,30 1,50 1,30 1,50
NOTE Material: steel, polished, surface roughness: Ra ≤ 0,4 μm.

3.2.1.2 Test sequence
Gauge A shall be placed over the outer contact of the connector once. This is a sizing
operation. After this, gauge B shall be placed over the outer contact in a vertical position. The
gauge shall be retained.
3.2.1.3 Gauge pin for socket-centre contact

7,6 mm max.
5,6 mm min.
a
IEC  996/09
Figure 4 – Gauge pin for socket contact (for dimensions, see Table 4)

– 10 – 61169-39 © IEC:2009(E)
Table 4 – Dimensions of gauge pin for socket contact
Gauge C Gauge D
(for sizing purposes) (for measurement of gauge retention force
for centre contact)
Mass (weight) of gauge: 600 g ± 5 g
Ref. mm mm
min max min max
a 6,05 6,10 5,95 6,00
NOTE Material: steel, polished, surface roughness: Ra ≤ 0,4 μm.
3.2.1.4 Test sequence
Test pin gauge C shall be inserted into the centre contact three times with a minimum depth
of 5,6 mm. This is a sizing operation and should only be carried out when the socket centre
contact is removed from the connector.
After this, gauge D shall be inserted and held in the vertical position. The gauge shall be
retained. This test can also be carried out on connector when the socket centre contact is not
removed once the sizing operation has been carried out on the contact whilst it was removed
from the connector.
61169-39 © IEC:2009(E) – 11 –
3.3 Dimensions – standard test connectors – Grade 0
3.3.1 Connector with pin-centre contact

m
Note 3
Note 1
n
u k
l
R0,5
∅0,05 mm A
8° ∼ 10°
d e f g s v t b a
c
A
x
y
B
i
Note 2
+0,1
∅0,05 mm
B
R1,5 j
h
IEC  997/09
Figure 5 – Connector of pin-centre contact (for dimensions, see Table 5)

– 12 – 61169-39 © IEC:2009(E)
Table 5 – Dimensions of connector with pin-centre contact
Reference mm Note
min max
a 5,99 6,00 Diameter
b 6,97 6,98 Diameter
c 16,05 16,07 Diameter
d 16,96 17,04 Diameter
e 18,05 18,15 Diameter
f 21,05 21,15 Diameter
g 21,95 22,05 Diameter
h 9,02 9,08
i 3,77 3,83
j 4,35 4,45
k 9,70 9,80
l 0,30 0,50
m 8,86 8,94
n 7,27 7,33
s 22,20 22,25 Diameter
t 23,04 23,10 Diameter
u 2,15 2,25
v 27,00 27,10 Diameter
x 4,20 4,40
y 7,20 7,40
NOTE 1 Mechanical reference plane.
NOTE 2 The spring force is 50 N to 60 N.
NOTE 3 Ring.
61169-39 © IEC:2009(E) – 13 –
3.3.2 Connector with socket-centre contact

Note 3
Note 5
g
h
Note 6
i f
u
Note 1
j
Note 2
b
d
n m e c
y
x
R0,3
Note 4
w v
1,5 × 45°
p
A
s
r
∅0,05 mm
q A
IEC  998/09
Figure 6 – Standard test connector with socket-centre contact
(for dimensions, see Table 6)
– 14 – 61169-39 © IEC:2009(E)
Table 6 – Dimensions of standard test connector with socket-centre contact
Reference mm Note
min max
b 16,05 16,07 Diameter
c 16,92 16,96 Diameter
d 18,01 18,05
e 22,18 22,25 Diameter
f 6,35 6,42
g 9,18 9,25
h 12,78 12,81
i 0,28 0,32
j - 0,20
m 23,68 23,75 Diameter
n 35,25 35,35 Diameter
p 0,88 0,96
q 1,06 1,14
r 1,60 -
s 2,60 -
u 4,95 5,05
v  See Note 4
w 6,97 7,00 Diameter
x 7,00 7,20
y 8,50 9,00
NOTE 1 Three steel balls, Ø3.
NOTE 2 Design for slotting optional, flared contacts Ød should be flared to Ø 18,40~Ø 18,50.
NOTE 3 Mechanical reference plane.
NOTE 4 When a gauge pin with diameter of 5,99 mm min 6 mm max is inserted into a depth of
5,00 mm min, dimension v should meet the requirements of dimension w.
NOTE 5 The spring force is 2 N to 6 N, movement is 1,60 mm min.
NOTE 6 Ring.
4 Quality assessment procedure
4.1 General
...


IEC 61169-39 ®
Edition 1.0 2009-06
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Radio-frequency connectors –
Part 39: Sectional specification for CQM series quick lock RF connectors

Connecteurs pour fréquences radioélectriques –
Partie 39: Spécification intermédiaire pour les connecteurs RF à verrouillage
rapide de la série CQM
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by
any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or
IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.

IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
 Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
 IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
 Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
 Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
 Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm
Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de référence,
texte, comité d’études,…). Il donne aussi des informations sur les projets et les publications retirées ou remplacées.
 Just Published CEI: www.iec.ch/online_news/justpub
Restez informé sur les nouvelles publications de la CEI. Just Published détaille deux fois par mois les nouvelles
publications parues. Disponible en-ligne et aussi par email.
 Electropedia: www.electropedia.org
Le premier dictionnaire en ligne au monde de termes électroniques et électriques. Il contient plus de 20 000 termes et
définitions en anglais et en français, ainsi que les termes équivalents dans les langues additionnelles. Egalement appelé
Vocabulaire Electrotechnique International en ligne.
 Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm
Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du
Service clients ou contactez-nous:
Email: csc@iec.ch
Tél.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 61169-39 ®
Edition 1.0 2009-06
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Radio-frequency connectors –
Part 39: Sectional specification for CQM series quick lock RF connectors

Connecteurs pour fréquences radioélectriques –
Partie 39: Spécification intermédiaire pour les connecteurs RF à verrouillage
rapide de la série CQM
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX U
ICS 33.120.30 ISBN 978-2-88912-392-6

– 2 – 61169-39  IEC:2009
CONTENTS
FOREWORD . 4
1 Scope . 6
2 Normative references . 6
3 Mating interface and gauge information . 6
3.1 Dimensions-General connectors – Grade 2 . 7
3.1.1 Connector with pin-centre contact . 7
3.1.2 Connectors with socket-centre contact . 8
3.2 Gauges . 9
3.2.1 Connectors with socket-centre contact . 9
3.3 Dimensions – standard test connectors – Grade 0 . 11
3.3.1 Connector with pin-centre contact . 11
3.3.2 Connector with socket-centre contact . 13
4 Quality assessment procedure . 14
4.1 General . 14
4.2 Rating and characteristics (see Clause 6 of IEC 61169-1) . 14
4.3 Test schedule and inspection requirements . 17
4.3.1 Acceptance tests . 17
4.3.2 Periodic tests . 18
4.4 Procedures . 19
4.4.1 Quality conformance inspection . 19
4.4.2 Qualification approval and its maintenance . 19
5 Instructions for preparation of detail specifications . 19
5.1 General . 19
5.2 Identification of the detail specification . 20
5.3 Identification of the component . 20
5.4 Performance . 20
5.5 Marking, ordering information and related matters . 20
5.6 Selection of tests, test conditions and severities . 20
5.7 Blank detail specification pro-forma for type CQM connector . 21
Bibliography . 26

Figure 1 – Connector with pin-centre contact (for dimensions, see Table 1) . 7
Figure 2 – Connector with socket-centre contact (for dimensions, see Table 2) . 8
Figure 3 – Gauge for outer contact of socket connector (for dimensions, see Table 3) . 9
Figure 4 – Gauge pin for socket contact (for dimensions, see Table 4) . 9
Figure 5 – Connector of pin-centre contact (for dimensions, see Table 5) . 11
Figure 6 – Standard test connector with socket-centre contact (for dimensions, see
Table 6) . 13

Table 1 – Dimensions of connector with pin-centre contact . 7
Table 2 – Dimensions of connector with socket-centre contact . 8
Table 3 – Dimensions of gauge for outer contact of socket connector . 9
Table 4 – Dimensions of gauge pin for socket contact . 10
Table 5 – Dimensions of connector with pin-centre contact . 12

61169-39  IEC:2009 – 3 –
Table 6 – Dimensions of standard test connector with socket-centre contact . 14
Table 7 – Ratings and characteristics . 15
Table 8 – Acceptance tests . 17
Table 9 – Periodic tests . 18

– 4 – 61169-39  IEC:2009
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO-FREQUENCY CONNECTORS –
Part 39: Sectional specification for CQM
series quick lock RF connectors

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61169-39 has been prepared by subcommittee 46F: RF and
microwave passive components, of IEC technical committee 46: Cables, wires, waveguides,
R.F. connectors, R.F. and microwave passive components and accessories.
This bilingual version, published in 2011-04, corresponds to the English version.
The text of this standard is based on the following documents:
CDV Report on voting
46F/107/CDV 46F/133/RVC
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
The French version of this standard has not been voted upon

61169-39  IEC:2009 – 5 –
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
A list of all parts of the IEC 61169 series can be found, under the general title Radio-
frequency connectors, on the IEC website.

IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
– 6 – 61169-39  IEC:2009
RADIO-FREQUENCY CONNECTORS –
Part 39: Sectional specification for CQM
series quick lock RF connectors

1 Scope
CQM series quick lock connectors with characteristic impedance 50 Ω are used for high
power microwave applications, connecting with RF cables or microstrips. The operating
frequency limit is at least 4 GHz.
This sectional specification provides information and rules for the preparation of detail
specifications for CQM series quick lock RF connectors together with the pro forma blank
detail specification (DS).
It also prescribes mating interface dimensions for general purpose connectors, dimensional
details of standard test connectors grade 0, gauging information and tests selected from
IEC 61169-1, applicable to all detail specifications relating to CQM series connectors.
This specification indicates the recommended performance characteristics to be considered
when writing a detail specification and it covers test schedules and inspection requirements
for assessment levels M and H.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 61169-1:1992, Radio-frequency connectors – Part 1: Generic specification – General
requirements and measuring methods
3 Mating interface and gauge information
All undimensioned pictorial configurations are for reference purposes only.

61169-39  IEC:2009 – 7 –
3.1 Dimensions – General connectors – Grade 2
3.1.1 Connector with pin-centre contact

m
Note 4 Note 1
n
p
u k
l
a b c d e f g s v t
+0,1 i
R1,5
Note 2 Note 3
j
h
IEC  993/09
Figure 1 – Connector with pin-centre contact (for dimensions, see Table 1)
Table 1 – Dimensions of connector with pin-centre contact
Reference mm Note
Min. Max.
a 5,96 6,04 Diameter
b 7 (nominal) Diameter
c 15,85 16,25 Diameter
d 16,90 17,10 Diameter
e 18,00 18,20 Diameter
f 21,00 21,20 Diameter
g 21,90 22,10 Diameter
h 8,90 9,20
i 3,70 3,90
j 4,30 4,50
k - 9,80
l 0,30 0,50
m 8,80 9,00
n 7,20 7,40
p 4,20 4,40
s 23,20 23,30 Diameter
t 35,00 35,20 Diameter
u 2,10 2,30
v 26,9 27,2 Diameter
NOTE 1 Mechanical reference plane.
NOTE 2 The spring force is 50 N to 60 N max.
NOTE 3 Tolerances of dimensions are to meet the requirements of characteristic impedances.
NOTE 4 Ring.
– 8 – 61169-39  IEC:2009
3.1.2 Connectors with socket-centre contact

Note 3
Note 5
g
h
Note 6 i f
u
Note 4
j
Note 2
Note 1
n m e c a
d b
1,5 × 45° s
r
p
k
q
l
IEC  994/09
Figure 2 – Connector with socket-centre contact (for dimensions, see Table 2)
Table 2 – Dimensions of connector with socket-centre contact
Reference mm Note
Min. Max.
a Diameter (Note 1)
7(nominal)
b 15,85 16,25 Diameter
c 16,70 16,90 Diameter
d 17,80 18,00 Diameter
e 22,10 22,30 Diameter
f 6,30 6,50
g 9,10 9,30
h 12,75 12,85
i 0,20 0,40
j -- 0,20
k 7,00 7,50
l 8,50 9,00
m 23,60 23,80 Diameter
n 35,20 35,40 Diameter
p 0,80 1,00
q 1,10 1,30
r 1,60 --
s 2,60 --
u 4,90 5,20
NOTE 1 Design for slotting optional, closed contacts should meet electrical and mechanical requirements.
NOTE 2 Design for slotting optional, flared contacts Ød should be flared to Ø18,4~Ø18,5.
NOTE 3 Mechanical reference plane.
NOTE 4 Three steel balls, Ø3.
NOTE 5 The spring force is 2 N to 6 N, movement is 1,60 mm min.
NOTE 6 Ring.
61169-39  IEC:2009 – 9 –
3.2 Gauges
3.2.1 Connectors with socket-centre contact
3.2.1.1 Gauge for outer contact of socket connector

v
w
s t u
IEC  995/09
Figure 3 – Gauge for outer contact of socket connector (for dimensions, see Table 3)
Table 3 – Dimensions of gauge for outer contact of socket connector
Gauge A Gauge B Note
(for sizing purposes) (for measurement of gauge retention force for outer
conductor)
Mass (weight) of gauge: 200 g ± 5 g
Ref. mm mm
Min. Max. Min. Max.
s 18,05 18,10 18,15 18,18
t 18,70 18,80 18,70 18,80
u 20,00 20,80 20,00 20,80
v 9,50 9,60 9,40 9,50
w 1,30 1,50 1,30 1,50
NOTE Material: steel, polished, surface roughness: Ra ≤ 0,4 μm.

3.2.1.2 Test sequence
Gauge A shall be placed over the outer contact of the connector once. This is a sizing
operation. After this, gauge B shall be placed over the outer contact in a vertical position. The
gauge shall be retained.
3.2.1.3 Gauge pin for socket-centre contact

7,6 mm max.
5,6 mm min.
a
IEC  996/09
Figure 4 – Gauge pin for socket contact (for dimensions, see Table 4)

– 10 – 61169-39  IEC:2009
Table 4 – Dimensions of gauge pin for socket contact
Gauge C Gauge D
(for sizing purposes) (for measurement of gauge retention force
for centre contact)
Mass (weight) of gauge: 600 g ± 5 g
Ref. mm mm
Min. Max. Min. Max.
a 6,05 6,10 5,95 6,00
NOTE Material: steel, polished, surface roughness: Ra ≤ 0,4 μm.
3.2.1.4 Test sequence
Test pin gauge C shall be inserted into the centre contact three times with a minimum depth
of 5,6 mm. This is a sizing operation and should only be carried out when the socket centre
contact is removed from the connector.
After this, gauge D shall be inserted and held in the vertical position. The gauge shall be
retained. This test can also be carried out on connector when the socket centre contact is not
removed once the sizing operation has been carried out on the contact whilst it was removed
from the connector.
61169-39  IEC:2009 – 11 –
3.3 Dimensions – standard test connectors – Grade 0
3.3.1 Connector with pin-centre contact

m
Note 3
Note 1
n
u k
l
R0,5
∅0,05 mm A
8° ∼ 10°
d e f g s v t b a
c
A
x
y
B
i
Note 2
+0,1
∅0,05 mm
B
R1,5 j
h
IEC  997/09
Figure 5 – Connector of pin-centre contact (for dimensions, see Table 5)

– 12 – 61169-39  IEC:2009
Table 5 – Dimensions of connector with pin-centre contact
Reference mm Note
Min. Max.
a 5,99 6,00 Diameter
b 6,97 6,98 Diameter
c 16,05 16,07 Diameter
d 16,96 17,04 Diameter
e 18,05 18,15 Diameter
f 21,05 21,15 Diameter
g 21,95 22,05 Diameter
h 9,02 9,08
i 3,77 3,83
j 4,35 4,45
k 9,70 9,80
l 0,30 0,50
m 8,86 8,94
n 7,27 7,33
s 22,20 22,25 Diameter
t 23,04 23,10 Diameter
u 2,15 2,25
v 27,00 27,10 Diameter
x 4,20 4,40
y 7,20 7,40
NOTE 1 Mechanical reference plane.
NOTE 2 The spring force is 50 N to 60 N.
NOTE 3 Ring.
61169-39  IEC:2009 – 13 –
3.3.2 Connector with socket-centre contact

Note 3
Note 5
h g
Note 6
i f
u
Note 1
j
Note 2
d b
n m e c
y
x
R0,3
Note 4
w v
1,5 × 45°
p
A
s
r
∅0,05 mm
q A
IEC  998/09
Figure 6 – Standard test connector with socket-centre contact
(for dimensions, see Table 6)
– 14 – 61169-39  IEC:2009
Table 6 – Dimensions of standard test connector with socket-centre contact
Reference mm Note
Min. Max.
b 16,05 16,07 Diameter
c 16,92 16,96 Diameter
d 18,01 18,05
e 22,18 22,25 Diameter
f 6,35 6,42
g 9,18 9,25
h 12,78 12,81
i 0,28 0,32
j - 0,20
m  23,68 23,75 Diameter
n 35,25 35,35 Diameter
p 0,88 0,96
q 1,06 1,14
r 1,60 -
s 2,60 -
u 4,95 5,05
v  See Note 4
w 6,97 7,00 Diameter
x 7,00 7,20
y 8,50 9,00
NOTE 1 Three steel balls, Ø3.
NOTE 2 Design for slotting optional, flared contacts Ød should be flared to Ø 18,40~Ø 18,50.
NOTE 3 Mechanical reference plane.
NOTE 4 When a gauge pin with diameter of 5,99 mm min 6 mm max is inserted into a depth of
5,00 mm min, dimension v should meet the requirements of dimension w.
NOTE 5 The spring force is 2 N to 6 N, movement is 1,60 mm min.
NOTE 6 Ring.
4 Quality assessment procedure
4.1 General
The following clauses provide recommended rating, performance and test conditions to be
considered when writing a detail specification (DS). They also provide an appropriate
schedule of tests with minimum levels of conformance inspection sampling, together with the
pro forma blank detail specification (BDS) and instructions for the preparation of a detail
specification.
4.2 Rating and characteristics (see Clause 6 of IEC 61169-1)
The values indicated below (see Table 7) are recommended for CQM series quick lock
connectors and are given for the writer of the detail specification. They are applicable for the
condition when the connectors are fully mated.

61169-39  IEC:2009 – 15 –
Certain tests are listed without any recommended values being given. These tests will usually
not be required. When these tests are required, appropriate values shall be entered in the
detail specification at the discretion of the specification writer.
Table 7 – Ratings and characteristics
Ratings and characteristics IEC 61169-1 Value Remarks
Subclause including any deviations
from standard test methods
Electrical
Nominal impedance
50 Ω
Frequency range Up to 4 GHz Or upper frequency limit of the
– Grade 2 connectors cable
Reflection factor 49.2.14.
a
7≤ 0,1 %
– straight styles
– right angle styles As specified in the
DS
– component mounting styles As specified in the
DS
– solder bucket and PCB mounting styles As specified in the
DS
Centre contact resistance 9.2.3
– initial
≤ 3 mΩ
– after conditioning
≤ 5 mΩ
a
9.2.3
Outer conductor continuity
– initial ≤ 3 mΩ
– after conditioning
≤ 5 mΩ
a
.9.2.5
Insulation resistance
– initial ≥ 5 GΩ
– after conditioning ≥ 500 MΩ
b c
.9.2.6 2 700 V (86~106 kPa)
Proof voltage at sea level
b c
.9.2.6 350 V 4,4 kPa approximately equivalent
Proof voltage at 4,4 kPa
to 20 km
c d
9. .9.4.63.3 2 000 V (86~106 kPa)
Environmental test voltage at sea level
g
.9.2.8 90 dB to 1 GHz
Z ≤ 0,02 mΩ applied torque 25 Nm
Screening effectiveness t
Discharge test (Corona) .9.2.9 Extinction voltage
≥ 1 000 V
– at sea level
(cable 60096 IEC 50-3)
– 16 – 61169-39  IEC:2009
Ratings and characteristics IEC 61169-1 Value Remarks
Subclause including any deviations
from standard test methods
Mechanical
Centre contact captivation 9.3.5 Maximum displacement 0,25 mm
each direction
– axial force 15 N, 1 min
f
– torque
N/A
Engagement and separation force
9.3.6
– engagement force
≤ 150 N
– separation force
>10 N & <22 N
Gauge retention force 9.3.4
(resilient contacts)
– centre
>6 N
– outer
>2 N
Mechanical tests on cable fixing 9.3.7
Cable pulling 9.3.8 See DS
cable rotation (nutation) 9.3.7.2 See DS
Cable bending 9.3.9 See DS
Cable torsion 9.3.10 See DS
Tensile strength of coupling mechanism 9.3.11 150 N
Bending moment 9.3.12 N/A
(and sharing force)
Vibration
100 m/s
9.3.3 10 g acceleration
n
10 Hz – 500 Hz
Bump
9.3.13 –
Shock 9.3.14
750 m/s
75 g acceleration
n
½ sin  6 ms
Environmental
e
55/155/56
Climatic category
Sealing – non-hermetic 9.4.5.1
1 cm /h max.
100 kPa – 110 kPa
differential
Salt mist 9.4.6 Duration of
spraying: 48 h
Endurance
Mechanical 0,19.57.10 5 000 operations
e
0,9.69.
1 000 h at 155 °C
High temperature
a
These values apply to basic connectors. They depend on the cable used. Relevant values are given in the DS.
b
Value for a single pair of mated connector.
c
Voltage values are r.m.s. values at 40 Hz to 60 Hz, unless otherwise specified.
d
Cables used with these connectors may have values of lower performance than those given in this table.
e
For certain connectors the upper temperature limit is restricted by the cable characteristics. Reference should be
made to the relevant cable specification.
f
N/A= Not applicable.
g
When interfaces are fully mated.

61169-39  IEC:2009 – 17 –
4.3 Test schedule and inspection requirements
4.3.1 Acceptance tests
Table 8 – Acceptance tests
Test Assessment level M (higher) Assessment level H (lower)
method
Test IL AQL Period Test IL AQL Period
IEC 61169-1
required % required %
Subclause
Group A1
Visual examination 9.1.2 a II 1,0 a S3 1,5
Group B1
Outline dimensions 9.1.3.1 a S4 0,4 a S3 4,0
Mechanical compatibility 9.1.3.3 a II 1,0 a S3 1,5
Engagement and 9.3.6 a S4 0,40 Lot a S3 1,5 Lot
separation
Gauge retention 9.3.4 ia II 1,0 ia S3 1,5
(resilient contact)
Sealing, non-hermetic 9.4.5.1 ia II 0,65 by ia S3 1,0 by
Sealing, hermetic 9.4.5.2 ia II 0,015 ia S3 0,025
Voltage proof 9.2.6 a S4 0,40 lot a II 4,0 lot
Solderability piece parts 9.3.2.1.1 ia S4 0,40 ia S3 4,0
Insulation resistance 9.2.5 a S4 0,40 a S3 4,0

– 18 – 61169-39  IEC:2009
4.3.2 Periodic tests
There are no group C tests for levels H and M.
Table 9 – Periodic tests
Test method
Assessment level M (higher) Assessment level H (lower)
IEC 61169-1
subclause
Test Number of Permitted Period Test Number of Permitted Period
required specimens failures required specimens failures
per per
group# group#
Group D1 (d)  6 1 3 3 1 3 years
years
Solderability 9.3.2.1.1 ia  ia
connector
assemblies
Resistance to 9.3.2.1.2 ia  ia
soldering heat
Mechanical
tests on cable
fixing
- cable rotation 9.3.7.2 na  na
(nutation)
- cable pulling 9.3.8 ia  ia
- cable bending 9.3.9 ia  ia
- cable torsion 9.3.10 ia  ia
Group D2 (d)  6 1 3 3 1 3 years
years
Contact 9.2.3 a  a
resistance,
outer conductor
and screen
continuity
centre
conductor
continuity
Vibration 9.3.3 a
Damp heat, 9.4.3 a  a
steady state
Group D3 (d)  1* 1 3 1* 1 3 years
years
Dimensions 9.1.3.2 a  a
piece-parts and
materials
Group D4 (d)  6 1 3 3 1 3 years
years
Mechanical 9.5 a  a
endurance
High 9.6 a  a
temperature
endurance
Sulphur dioxide 9.4.8 na  na
Group D5 (d)  6 1 3 3 1 3 years
years
Reflection 9.2.1 a  a
factor
61169-39  IEC:2009 – 19 –
Test method
Assessment level M (higher) Assessment level H (lower)
IEC 61169-1
subclause
Test Number of Permitted Period Test Number of Permitted Period
required specimens failures required specimens failures
per per
group# group#
Screening 9.2.8 a  a
effectiveness
Water 9.2.7 ia  ia
immersion
Group D6 (d)  6 1 3 3 1 3 years
years
Contact 9.3.5 a  a
captivation
Rapid change 9.4.4 na  na
of temperature
Climatic 9.4.2 a  a
sequence
Group D7 (d)  1§ 3 1§ 3 years
years
Resistance to 9.7 ia  ia
solvents and
contaminating
fluids
Details of symbols, abbreviations and procedures:
a = suggested as applicable
ia = test suggested (if technically applicable)
na = not applicable
* = one set of piece-parts each style and variant, unless using common piece parts
# = for qualification approval (QA) a total of two failures only permitted for level H and 1 failure only for level M
from groups D1 to D7
§ = Group D7 – number of pairs for each solvent
(d) = destructive tests – specimens shall not be returned to stock

4.4 Procedures
4.4.1 Quality conformance inspection
This shall consist of test groups A1 and B1 on a lot-by-lot basis.
4.4.2 Qualification approval and its maintenance
This shall consist of three consecutive lots passing test groups A1 and B1 followed by
selection of specimens from the lots as appropriate. These specimens shall successfully pass
the specified periodic D tests.
5 Instructions for preparation of detail specifications
5.1 General
Detail specifications (DS) writers shall use the appropriate BDS pro-forma. The following
pages comprise the pro-forma BDS dedicated for use with type CQM connectors. As such, it
will already have entered on it information relating to:

– 20 – 61169-39  IEC:2009
a) the basic specification number applicable to all the detail specifications covering
connector styles of the type covered by the sectional specification;
b) the connector series designation.
The specification writer should enter the details relating to the connector style/variant(s) to be
covered as indicated. The numbers in brackets on the BDS pro-forma correspond to the
following indications which shall be given.
5.2 Identification of the detail specification
(1) The name of the national standards organization (NSO) under whose authority the DS
is published and, if applicable, the organization from whom the DS is available.
(2) The relevant mark of conformity and the number allotted to the DS by the relevant
national or international organization authorizing the DS.
(3) The number and issue number of the IEC generic or sectional specification as
relevant; also national reference if different.
(4) If different from the IEC number, any national number of the DS, date of issue and any
further information required by the national system, together with any amendment
numbers.
5.3 Identification of the component
(5) Enter the following details:
Style:    The style designation of the connector including type of fixing and sealing,
if applicable.
Attachment: By deletion of the inapplicable options of cable/wire: given for centre and
outer conductors.
Special features and markings: As applicable.
(6) Enter details of assessment level and the climatic category.
(7) A reproduction of the outline drawing and details of the panel piercing, if applicable. It
shall provide the maximum envelope dimensions, also the position of the reference
plane and, in the case of a fixed connector, the position of the mounting plane(s)
relative to the front face of the connector.
Any maximum panel thickness limitations for fixed connectors shall be stated.
(8) Particulars of all variants covered by the DS. As appropriate, the information shall
include:
• cable types (or sizes) applicable to each variant;
• alternative plated or protective finishes;
• details of alternative mounting flanges having either tapped or plain mounting
holes;
• details of alternative solder spills or solder buckets including, when applicable,
those for use with microwave integrated circuit (MIC) components.
5.4 Performance
(9) Performance data listing the most important characteristics of the connector taking
into account the recommended values of 4.2 in this specification. Deviations from the
minimum requirements shall be clearly indicated. Non-applicable parameters shall be
marked ‘na’.
5.5 Marking, ordering information and related matters
(10) Insert marking and ordering information as appropriate, together with details of related
documents and any invoked structural similarity.
5.6 Selection of tests, test conditions and severities
(11) ‘na’ shall be used to indicate non-applicable tests. All tests marked ‘a’ by the detail
specification writer shall be mandatory.

61169-39  IEC:2009 – 21 –
When using the normal procedure with a dedicated BDS, the letter ‘a’ – for applicable
– shall be entered in the ‘Test required’ column against each of the tests indicated as
being mandatory in the test schedule as in 4.3 of this specification. Any additional
tests required at the discretion of the specification writer shall also be indicated by an
‘a’.
The specification writer shall also indicate, when necessary, details of deviations from
the standard test methods and test conditions, including any relevant deviations given
in the test schedule of the sectional specification.
The qualification approval and conformance inspection shall be such that the national
supervising inspectorate (NSI) shall be satisfied that they are appropriate and in line with
those for other connectors within the system providing a reasonably comparable service.
5.7 Blank detail specification pro-forma for type CQM connector
The following pages contain the complete BDS pro-forma.
(1)
Page 1 of ….
IEC 61169-1
ELECTRONIC COMPONENT OF ASSESSED (4) ISSUE
QUALITY IN ACCORDANCE WITH
GENERIC SPECIFICATION IEC 61169-1 .
NATIONAL REFERENCE
........................
(5) Detail specification for type CQM
Radio frequency coaxial connector of assessed quality
Style:. Special features and markings
Method of cable/wire+ attachment centre conductor – solder/crimp+
outer conductor – solder/clamp/crimp +
+ delete as appropriate
(6) Assessment level. Characteristic impedance 50 Ω Climatic category./././
(7) Outline and maximum dimensions Panel piercing and mounting details
(8) Variants
Variant No. Description of variant 60096 IEC
01. . . . . .
............. ............. ............. ............. ............. .............
............. ............. ............. ............. ............. .............
............. ............. ............. ............. ............. .............
............. ............. ............. ............. ............. .............
............. ............. ............. ............. ............. .............
............. ............. ............. ............. ............. .............
............. ............. ............. ............. ............. .............
............. ............. ............. ............. .............
Information about manufacturers who have components qualified to this detail specification is available through IECQ on-line
certificate system.
– 22 – 61169-39  IEC:2009
(9) Performance (including limiting conditions of use)
Remarks including any
Ratings and characteristics
IEC 61169-1
Value deviations from standard test
subclause
methods (11)
Electrical
Nominal impedance  ….Ω
Frequency range  …4 GHz Measurement frequency range
Reflection factor 9.2.1
Variant No.
Designation
01. . .
........... ........... ...........
Centre contact resistance 9.2.3 Initial
≤ .mΩ
After conditioning
≤.mΩ
Centre conductor 01. 9.2.3 Resistance change due to
.............mΩ
continuity . conditioning
.............mΩ
............
.............mΩ
..............
.............mΩ
Outer contact continuity 9.2.3 ≤ .mΩ Initial
After conditioning
≤.mΩ
Insulation resistance 9.2.5 ≥.GΩ Initial
After conditioning
≥.GΩ
+ Proof voltage at sea 01. 9.2.6 .kV 86 kPa to 106 kPa
level . .kV
............ ..............kV
.............. ..............kV
+ Proof voltage at 4,4 kPa 01. 9.2.6 .V .kPa (if not 4,4 kPa)
........... ...............V
............ ...............V
.............. ...............V
Environmental test voltage .9.4.6 ……………V (86 kPa to 106 kPa)
at sea level
Screening effectiveness 01. 9.2.8 .dB at.GHz
Z ≤. mΩ
t
...........
............
..............
Discharge test (corona) at 01. 9.2.9 Extinction voltage
≥. V
sea level .
≥. V
............
≥. V
..............
≥. V
ADDITIONAL
ELECTRICAL
CHARACTERISTICS
+ Voltage values are r.m.s. values at 50 Hz to 60 Hz, unless otherwise specified.

61169-39  IEC:2009 – 23 –
Remarks including any
IEC 61169-1
Ratings and characteristics Value deviations from standard test
subclause
methods
Mechanical
Soldering 9.3.2.1.1
- bit size .
Gauge retention resilient  For gauging details, see
contacts 3.1.2 Figure 4 and Table 4, Figure 3
................N
- inner contact and Table 3 of IEC 61169-1
................N
- outer contact
Centre contact captivation 9.3.5
- axial force .N
- permitted displacement .mm
each direction
- torque .Nm
Engagement and 9.3.6
separation
……………N
- engagement force
……………N
- separation force
Strength of coupling 9.3.11 ……………N
mechanism
Effectiveness of cable
fixing against
Bend radius and number of
- cable rotation 01. 9.3.7 Rotations revolutions
........... .................
............ ..................
.............. .................
- cable pulling 01. 9.3.8 .N Point of application and duration
........... ...........
............ ............
.............. ..............
- cable bending 01. 9.3.9 .Cycles Length of cable mass
........... ........... ................. ..........
............ ............ ................. ..........
.............. .............. ................. ..........
- cable torsion 01. 9.3.10 .…Nm Duration of applied torque
........... ...........
............ ............
.............. ..............
Bending moment 9.3.12 .…Nm Relative to reference plane
Bumps total 9.3.13 (.g acceleration)
........…m/s n
…….to…. Hz
Vibration 9.3.3 .…m/s² (.g acceleration)
n
......to..….. Hz
Shock 9.3.14 (.g acceleration)
n
........…m/s
........…Shape
........…ms
ADDITIONAL
MECHANICAL
CHARACTERISTICS
– 24 – 61169-39  IEC:2009
Remarks including any
IEC 61169-1
Ratings and characteristics Value deviations from standard test
subclause
methods
Environmental
Climatic category  ././.
Sealing non-hermetically 9.4.5.1 .cm /h 100 kPa to 110 kPa pressure
sealed connectors differential
–5 3
Sealing hermetically sealed 9.4.5.2 10 bar/cm /h 100 kPa to 110 kPa pressure
connectors differential
Water immersion 9.2.7
Salt mist 9.4.6 ……… h Duration of spraying
ADDITIONAL
ENVIRONMENTAL
CHARACTERISTICS
ENDURANCE
Mechanical 9.5 ….operations
High temperature 9.6 .h
at.°C
ADDITIONAL ENDURANCE
CHARACTERISTICS
CHEMICAL CONTAMINATION
Resistance to solvents and 9.7 .
contaminating fluids to be .
used. .
...............
Applicable fluids.
...............
...............
...............
Sulphur dioxide 9.4.8 . days

61169-39  IEC:2009 – 25 –
(10) Supplementary information
– Marking of the component: in accordance with 11.1 of IEC 61169-1 in the following
order of preference:
1) Manufacturer code: .
2) Manufacturing date code: year/week
3) Component identification: Variant No./  Identification
Designation
..................................
..................................
..................................
..................................
..................................
..................................
..................................
...................................
– Marking and contents of package: in accordance with 11.2 of IEC 61169-1
1) Information prescribed in 11.1 of IEC 61169-1 detailed above
2) Nominal characteristic impedance . …Ω.
3) Assessment level code letter .
4) Any additional marking required .

Ordering information
1) Number of the detail specification IEC 61169-39./Variant code.
2) Assessment level code letter .
3) Body finish (if more than one listed) .
4) Any additional information or
special requirements .
– Related documents (if not included in IEC 61169-1 or sectional specification):
............................................................................................................
.............................................................................................................
– St
...