IEC 61169-70:2024, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) of HD-BNC series RF coaxial connectors together with the pro forma blank detail specification. HD-BNC series connectors with characteristic impedance of 75 Ω are used with RF cables or micro-strips in microwave, telecommunication, wireless and other fields. The operating frequency limit is up to 18 GHz.
It also prescribes mating face dimensions for general purpose connectors, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to series HD-BNC RF connectors.
This specification indicates the recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61169-10:2024, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for series SMB RF coaxial connectors with snap-on coupling with a characteristic impedance of 50 Ω.
This document prescribes mating face dimensions for high performance connectors – grade 2, dimensional details of standard test connectors − grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to series SMB RF connectors.
This document indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.
The series SMB connectors are used to connect with all kinds of RF cables and microstrips in microwave transmission systems. The operating frequency is up to 4 GHz.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61169-10:2024, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for series SMB RF coaxial connectors with snap-on coupling with a characteristic impedance of 50 Ω. This document prescribes mating face dimensions for high performance connectors – grade 2, dimensional details of standard test connectors − grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to series SMB RF connectors. This document indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H. The series SMB connectors are used to connect with all kinds of RF cables and microstrips in microwave transmission systems. The operating frequency is up to 4 GHz.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61169-10:2024, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for series SMB RF coaxial connectors with snap-on coupling with a characteristic impedance of 50 Ω.
This document prescribes mating face dimensions for high performance connectors – grade 2, dimensional details of standard test connectors − grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to series SMB RF connectors.
This document indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.
The series SMB connectors are used to connect with all kinds of RF cables and microstrips in microwave transmission systems. The operating frequency is up to 4 GHz.

  • Standard
    52 pages
    English and French language
    sale 15% off

This part of IEC 63138, which is a sectional specification (SS), provides information and rules
for the preparation of detail specifications (DS) for MQ4 series circular connectors with four RF
channels, as well as a detailed specification of the blank format.
An MQ4 series circular connector with 50 Ω nominal impedance has four RF channels which
can be engaged and disengaged at the same time. There are two versions of plug connectors,
one is a quick-lock version, and the other is a threaded version. The socket connector provides
two coupling mechanisms, a quick-lock and a threaded coupling.
MQ4 series circular connectors can be used in mobile communication systems and in other
communication equipment.
This document also specifies the mating face dimensions and gauging information of MQ4
series circular connectors, and tests selected from IEC 63138-1, applicable to all detail
specifications relating to MQ4 series circular connectors.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63138-2:2023 is available as IEC 63138-2:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 63138-2:2023, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for MQ4 series circular connectors with four RF channels, as well as a detailed specification of the blank format. An MQ4 series circular connector with 50 Ω nominal impedance has four RF channels which can be engaged and disengaged at the same time. There are two versions of plug connectors, one is a quick-lock version, and the other is a threaded version. The socket connector provides two coupling mechanisms, a quick-lock and a threaded coupling. MQ4 series circular connectors can be used in mobile communication systems and in other communication equipment. This document also specifies the mating face dimensions and gauging information of MQ4 series circular connectors, and tests selected from IEC 63138-1, applicable to all detail specifications relating to MQ4 series circular connectors.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63138-2:2023 is available as IEC 63138-2:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 63138-2:2023, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for MQ4 series circular connectors with four RF channels, as well as a detailed specification of the blank format. An MQ4 series circular connector with 50 Ω nominal impedance has four RF channels which can be engaged and disengaged at the same time. There are two versions of plug connectors, one is a quick-lock version, and the other is a threaded version. The socket connector provides two coupling mechanisms, a quick-lock and a threaded coupling. MQ4 series circular connectors can be used in mobile communication systems and in other communication equipment. This document also specifies the mating face dimensions and gauging information of MQ4 series circular connectors, and tests selected from IEC 63138-1, applicable to all detail specifications relating to MQ4 series circular connectors.

  • Standard
    94 pages
    English language
    sale 15% off
  • Standard
    58 pages
    English and French language
    sale 15% off

IEC 62680-1-3:2022 defines the USB Type-C® receptacles, plug and cables. The USB Type-C Cable and Connector Specification is guided by the following principles:
- Enable new and exciting host and device form-factors where size, industrial design and style are important parameters
- Work seamlessly with existing USB host and device silicon solutions
- Enhance ease of use for connecting USB devices with a focus on minimizing user confusion for plug and cable orientation
The USB Type-C Cable and Connector Specification defines a new receptacle, plug, cable and detection mechanisms that are compatible with existing USB interface electrical and functional specifications. This specification covers the following aspects that are needed to produce and use this new USB cable/connector solution in newer platforms and devices, and that interoperate with existing platforms and devices:
- USB Type-C receptacles, including electro-mechanical definition and performance requirements
- USB Type-C plugs and cable assemblies, including electro-mechanical definition and performance requirements
- USB Type-C to legacy cable assemblies and adapters
- USB Type-C-based device detection and interface configuration, including support for legacy connections
- USB Power Delivery optimized for the USB Type-C connector
The USB Type-C Cable and Connector Specification defines a standardized mechanism that supports Alternate Modes, such as repurposing the connector for docking-specific applications. IEC 62680-1-3:2022 cancels and replaces the fourth edition published in 2021 and constitutes a technical revision. This standard is the USB-IF publication Universal Serial Bus Type-C Cable and Connector Specification Revision 2.0. New release primarily for enabling Extended Power Range (EPR) and defining EPR cables aligning with USB Power Delivery Specification R3.1 V1.0. Also includes incorporation of all approved ECNs as the revision date plus editorial clean-up.

  • Standard
    392 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62037-8:2022 defines a radiated passive intermodulation (PIM) test to determine PIM levels generated by a device or object when it is exposed to RF radiation. This test can be conducted on any material or object and is not limited to devices designed to propagate RF signals. This test can be conducted as either a near field or far field test as defined by the test specification in an outdoor test site or in an anechoic test chamber.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62037-7:2022 defines test methods for reverse measurement of passive intermodulation (PIM) in systems of RF components deployed in the field. Field PIM measurements can be conducted on RF systems terminated into low PIM loads or on antenna feed systems that broadcast the test signals into the environment.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61169-4:2008(E) provides information and rules for the preparation of detail specifications (DS) for type 7-16 R.F. coaxial connectors with  screw lock. It describes the interface dimensions for general purpose grade 2 connectors, dimensional details for standard test connectors, grade 0, together with gauging information and the mandatory tests selected from QC 22000 (IEC 61169-1), applicable to all DS relating to type 7-16 connectors.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62680-1-8:2019 is to describe in detail all the Terminal Types that are supported by the Audio Device Class. This document is considered an integral part of the Audio Device Class Specification, although subsequent revisions of this document are independent of the revision evolution of the main Audio Device Class Specification. This is to easily accommodate the addition of new Terminal Types without impeding the core Audio Device Class Specification. The Audio Device Class Definition applies to all devices or functions embedded in composite devices. All audio signals inside an audio function start at an Input Terminal, pass through some Units, and leave the function through an Output Terminal. Units can manipulate the signal in various ways. Terminals represent the connections of the function to the outside world. As part of the Terminal descriptor, the wTerminalType field specifies the vendor’s suggested use of the Terminal. For example, a pair of speakers is a more suitable target for music output than a telephone line. This feature allows a vendor to ensure that applications use the device in a consistent and meaningful way.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63138-1:2019 which is a generic specification, specifies general requirements for multi-channel radio-frequency connectors, including terms and definitions, design and construction, ratings and characteristics, climatic categories, IEC type designation, requirements and test procedures, quality assessment, marking, etc. It provides the basis for establishing the sectional specifications for various multi­channel radio­frequency connector types. This document applies to multi-channel radio-frequency connectors (called "connectors", hereinafter) for use in communications, electronics and other equipment.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61169-1-2:2019 provides test methods for the insertion loss of radio-frequency (RF) connectors. This document is applicable to cable RF connectors, microstrip RF connectors and RF connector adapters. It is also applicable to RF channels in multi-RF channel connectors and hybrid connectors which contain any combination of coaxial contact, optical fibres contact, and current-carrying electrical contact element.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61169-64:2019, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for IEC 61169 (all parts) coaxial connectors with 0,8 mm coupling. The connectors are used with cables with characteristic impedance 50 Ω in an operating frequency range up to 145 GHz. The connectors are widely used in communications and measurements. It describes the interface dimensions for general purpose connectors with gauging information and the mandatory tests selected from IEC 61169-1, applicable to all detail specifications relative to type 0,8 connectors. This specification indicates the recommended performance characteristics to be considered when writing a DS and covers all tests schedules and inspection requirements.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62680-1-3:2022 defines the USB Type-C® receptacles, plug and cables. The USB Type-C Cable and Connector Specification is guided by the following principles: - Enable new and exciting host and device form-factors where size, industrial design and style are important parameters - Work seamlessly with existing USB host and device silicon solutions - Enhance ease of use for connecting USB devices with a focus on minimizing user confusion for plug and cable orientation The USB Type-C Cable and Connector Specification defines a new receptacle, plug, cable and detection mechanisms that are compatible with existing USB interface electrical and functional specifications. This specification covers the following aspects that are needed to produce and use this new USB cable/connector solution in newer platforms and devices, and that interoperate with existing platforms and devices: - USB Type-C receptacles, including electro-mechanical definition and performance requirements - USB Type-C plugs and cable assemblies, including electro-mechanical definition and performance requirements - USB Type-C to legacy cable assemblies and adapters - USB Type-C-based device detection and interface configuration, including support for legacy connections - USB Power Delivery optimized for the USB Type-C connector The USB Type-C Cable and Connector Specification defines a standardized mechanism that supports Alternate Modes, such as repurposing the connector for docking-specific applications. IEC 62680-1-3:2022 cancels and replaces the fourth edition published in 2021 and constitutes a technical revision. This standard is the USB-IF publication Universal Serial Bus Type-C Cable and Connector Specification Revision 2.0. New release primarily for enabling Extended Power Range (EPR) and defining EPR cables aligning with USB Power Delivery Specification R3.1 V1.0. Also includes incorporation of all approved ECNs as the revision date plus editorial clean-up.

  • Standard
    392 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard describes the measurement of screening attenuation by the reverberation chamber measurement method, also called mode stirred chamber method.
This standard is applicable to screening attenuation measurements of cable assemblies, cables, connectors, and passive microwave components, such as waveguides, phase shifters, diplexers/multiplexers, power dividers/combiners and etc.
Modern electronic equipments have shown a demand for methods for testing screening attenuation performance of microwave components over their whole frequency range. Convenient measurement methods have existed for lower frequencies and components of regular shape. These measurement methods are described in IEC 62153 series standards. For much higher frequencies and for components of irregular shape, the reverberation chamber method should be used. Theoretically, the reverberation chamber method has no upper limit of the measurement frequency, but it is limited by the quality and sensitivity of the measurement system, and the lower limit of the measurement frequency is restricted by the size of the reverberation chamber.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63137-1:2019 defines general requirements for standard test radio frequency (RF) connectors (grade 0), including terms and definitions, ratings and characteristics, general requirements, test methods, quality assessment procedures, and etc. Standard test radio frequency (RF) connectors (grade 0) are intended to measure grade 1 and grade 2 RF connectors for electrical performances. Typically, a standard test radio frequency (RF) connector (grade 0) is an adapter with one end (normally a precision connector interface) which can be connected with measurement equipment and the other end (normally a standard test connector interface) which can be connected with grade 1 or grade 2 connectors. This specification applies to grade 0 standard test connectors (called connector, hereinafter). The corrigendum of January 2020 applies to the French language only.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard describes the measurement of screening attenuation by the reverberation chamber measurement method, also called mode stirred chamber method. This standard is applicable to screening attenuation measurements of cable assemblies, cables, connectors, and passive microwave components, such as waveguides, phase shifters, diplexers/multiplexers, power dividers/combiners and etc. Modern electronic equipments have shown a demand for methods for testing screening attenuation performance of microwave components over their whole frequency range. Convenient measurement methods have existed for lower frequencies and components of regular shape. These measurement methods are described in IEC 62153 series standards. For much higher frequencies and for components of irregular shape, the reverberation chamber method should be used. Theoretically, the reverberation chamber method has no upper limit of the measurement frequency, but it is limited by the quality and sensitivity of the measurement system, and the lower limit of the measurement frequency is restricted by the size of the reverberation chamber.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62680-1-3:2022 defines the USB Type-C® receptacles, plug and cables. The USB Type-C Cable and Connector Specification is guided by the following principles:
- Enable new and exciting host and device form-factors where size, industrial design and style are important parameters
- Work seamlessly with existing USB host and device silicon solutions
- Enhance ease of use for connecting USB devices with a focus on minimizing user confusion for plug and cable orientation
The USB Type-C Cable and Connector Specification defines a new receptacle, plug, cable and detection mechanisms that are compatible with existing USB interface electrical and functional specifications. This specification covers the following aspects that are needed to produce and use this new USB cable/connector solution in newer platforms and devices, and that interoperate with existing platforms and devices:
- USB Type-C receptacles, including electro-mechanical definition and performance requirements
- USB Type-C plugs and cable assemblies, including electro-mechanical definition and performance requirements
- USB Type-C to legacy cable assemblies and adapters
- USB Type-C-based device detection and interface configuration, including support for legacy connections
- USB Power Delivery optimized for the USB Type-C connector
The USB Type-C Cable and Connector Specification defines a standardized mechanism that supports Alternate Modes, such as repurposing the connector for docking-specific applications. IEC 62680-1-3:2022 cancels and replaces the fourth edition published in 2021 and constitutes a technical revision. This standard is the USB-IF publication Universal Serial Bus Type-C Cable and Connector Specification Revision 2.0. New release primarily for enabling Extended Power Range (EPR) and defining EPR cables aligning with USB Power Delivery Specification R3.1 V1.0. Also includes incorporation of all approved ECNs as the revision date plus editorial clean-up.

  • Standard
    820 pages
    English and French language
    sale 15% off

This part of IEC 61169, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for RF coaxial connector, typically for use in 50 Ω radio communication systems, type NEX10®.
This document describes mating face dimensions for general purpose connectors - grade 2, dimensional details of standard test connectors-grade 1, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to type NEX10® RF coaxial connectors.
This specification indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.
The type NEX10® RF coaxial connectors are used with all kinds of RF cables and microstrip circuits in radio frequency transmission systems with operating frequencies up to 20 GHz.
NOTE Metric dimension are original dimensions. All undimensioned pictorial configurations are for reference purpose only.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61169, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for RF coaxial connector, typically for use in 50 Ω radio communication systems, type NEX10®. This document describes mating face dimensions for general purpose connectors - grade 2, dimensional details of standard test connectors-grade 1, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to type NEX10® RF coaxial connectors. This specification indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H. The type NEX10® RF coaxial connectors are used with all kinds of RF cables and microstrip circuits in radio frequency transmission systems with operating frequencies up to 20 GHz. NOTE Metric dimension are original dimensions. All undimensioned pictorial configurations are for reference purpose only.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61169-71:2022, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for RF coaxial connector, typically for use in 50 Ω radio communication systems, type NEX10® .
This document describes mating face dimensions for general purpose connectors (grade 2), dimensional details of standard test connectors (grade 1), gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to type NEX10® RF coaxial connectors.
This document indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.

  • Standard
    66 pages
    English and French language
    sale 15% off

This part of IEC 63138, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for MQ5 series circular connectors with five RF channels, as well as a detailed specification of the blank format.
An MQ5 series circular connector with 50 Ω nominal impedance has five RF channels that can be engaged and disengaged at the same time. There are two versions of plug connectors, one is a quick-lock version, and the other is a threaded version. The socket connector provides two coupling mechanisms, a quick-lock and a threaded coupling.
MQ5 series circular connectors can be used in mobile communication systems and in other communication equipment.
This document also specifies the mating face dimensions and gauging information of MQ5 series circular connectors, and tests selected from IEC 63138-1, applicable to all detail specifications relating to MQ5 series circular connectors.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61169, which is a sectional specification (SS), provides information and rules
for the preparation of detail specifications (DS) for series TNC RF coaxial connectors with
threaded coupling with a characteristic impedance of 50 Ω.
This document prescribes mating face dimensions for high performance connectors – grade 2,
dimensional details of standard test connectors − grade 0, gauging information and tests
selected from IEC 61169-1, applicable to all detail specifications relating to series TNC RF
connectors.
This document indicates recommended performance characteristics to be considered when
writing a detail specification and it covers test schedules and inspection requirements for
assessment levels M and H.
The series TNC connectors which are used with all kinds of RF cables and microstrips in
microwave transmission systems. The operating frequency is up to 11 GHz.
NOTE Metric dimension are original dimensions. All undimensioned pictorial configurations are for reference
purpose only

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard provides the requirements of WB series glass beads with 50Ω impedance for RF connectors, including the structure dimensions, IEC type designation, rating and characteristics and quality assessments, etc.
These glass beads are used for adaption of coaxial systems to microstrip circuits extensively in microwave communication systems such as TR modules, power modules, integrated circuits and etc. where hermetic seal is required. They can serve as a part of an RF coaxial connector, multi-channel RF connector or hybrid connector, or can be applied directly in various communication module systems as an independent product. They provide 50Ω normative impedance with operating frequency limit up to 65 GHz.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63138-3:2022, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for MQ5 series circular connectors with five RF channels, as well as a detailed specification of the blank format. This document also specifies the mating face dimensions and gauging information of MQ5 series circular connectors, and tests selected from IEC 63138-1, applicable to all detail specifications relating to MQ5 series circular connectors.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61169, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for series TRK bayonet coupling triaxial connectors. The series TRK bayonet coupling triaxial connectors with the advantages of quick connection and separation, high reliability, small size, good salt characteristics, four polarizations to prevent error-mate etc., can be connected with symmetrically twisted pair cables or triaxial cables. It has been widely used in 1553B data bus systems or other communication systems for digital signal transmission.
It prescribes mating face dimensions for series TRK bayonet coupling triaxial connectors, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to series TRK triaxial connectors.
This specification indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.
Note: Metric dimension are original dimensions. All undimensioned pictorial configurations are for reference purpose only.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61169 provides test methods for the rise time degradation of radio frequency
(RF) connector.
This document is applicable to triaxial and other radio frequency connectors.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides the requirements for WB series glass beads with 50 Ω impedance for RF connectors, including, among other, the structure dimensions, IEC type designation, rating and characteristics, and quality assessment. These glass beads are used for the adaption of coaxial systems to microstrip circuits used extensively in microwave communication systems such as TR modules, power modules, integrated circuits where hermetic seal is required. They can serve as a part of an RF coaxial connector, multi-channel RF connector or hybrid connector, or can be applied directly in various communication module systems as an independent product. They provide a 50 Ω normative impedance with an operating frequency limit up to 65 GHz.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61169-17:2022, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for series TNC RF coaxial connectors with threaded coupling with a characteristic impedance of 50 Ω. This document prescribes mating face dimensions for high performance connectors - grade 2, dimensional details of standard test connectors - grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to series TNC RF connectors. This document indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61169, which is a sectional specification (SS), provides information and rules for preparation of detail specification for type SC threaded RF coaxial connectors with 50 Ω characteristic impedance. The connectors are used with flexible and semi-rigid cables. And they are recommended to be utilized in medium power and low reflection applications up to 11 GHz. The dielectric filled interface is especially beneficial in applications involving severe environmental exposure.
It prescribes mating face dimensions, dimensional details, gauging information for general connectors - grade 2 and standard test connectors - grade 0 as well as test schedules and inspection requirements selected from IEC 61169-1, applicable to all detail specifications relating to type SC RF connectors. Type SC interface specified in this specification is equivalent to type SC-B interface in IEC 60169-21: 1985.
This specification indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.
NOTE: For this part, original dimensions are in inches. All undimensioned pictorial configurations are for reference purpose only.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61169 provides test methods for RF power rating and power handling of RF
connectors at specified frequency, temperature and altitude.
This document is applicable to cabled RF connectors, microstrip RF connectors and RF
connector adapters. It is also suitable to test RF channels in multi-channel RF connectors and
hybrid connectors.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61169, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for series TRL threaded triaxial connectors. Series TRL threaded triaxial connectors with high reliability, small size, good salt characteristics can be connected with symmetrically twisted pair cables or triaxial cables. It has been used in 1553B data bus systems or other communication systems for digital signal transmission.
It prescribes mating face dimensions for series TRL threaded triaxial connectors, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to series TRL threaded triaxial connectors.
This specification indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.
Note: Metric dimensions are original dimensions. All undimensioned pictorial configurations are for reference purpose only.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61169, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for series TRK bayonet coupling triaxial connectors. The series TRK bayonet coupling triaxial connectors having the advantages of quick connection and separation, high reliability, small size, good salt characteristics, four polarizations to prevent error-mate etc., can be connected to symmetrically twisted pair cables or triaxial cables. They have been widely used in 1553B data bus systems or other communication systems for digital signal transmission. It specifies mating face dimensions for series TRK bayonet coupling triaxial connectors, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to series TRK triaxial connectors. This document indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H. NOTE Metric dimension are original dimensions. All undimensioned pictorial configurations are for reference purpose only.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61169, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for series TRL threaded triaxial connectors. Series TRL threaded triaxial connectors with high reliability, small size, good salt characteristics can be connected with symmetrically twisted pair cables or triaxial cables. It has been used in 1553B data bus systems or other communication systems for digital signal transmission. It prescribes mating face dimensions for series TRL threaded triaxial connectors, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to series TRL threaded triaxial connectors. This specification indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H. Note: Metric dimensions are original dimensions. All undimensioned pictorial configurations are for reference purpose only.

  • Standard
    23 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61169, which is a sectional specification (SS), provides information and rules for preparation of detail specification for type SC threaded RF coaxial connectors with 50 Ω characteristic impedance. The connectors are used with flexible and semi-rigid cables. And they are recommended to be utilized in medium power and low reflection applications up to 11 GHz. The dielectric filled interface is especially beneficial in applications involving severe environmental exposure. It prescribes mating face dimensions, dimensional details, gauging information for general connectors - grade 2 and standard test connectors - grade 0 as well as test schedules and inspection requirements selected from IEC 61169-1, applicable to all detail specifications relating to type SC RF connectors. Type SC interface specified in this specification is equivalent to type SC-B interface in IEC 60169-21: 1985. This specification indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H. NOTE: For this part, original dimensions are in inches. All undimensioned pictorial configurations are for reference purpose only.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61169-1-6:2022 provides test methods for RF power rating and power handling of RF connectors at specified frequency, temperature and altitude. This document is applicable to cabled RF connectors, microstrip RF connectors and RF connector adapters. It is also suitable to test RF channels in multi-channel RF connectors and hybrid connectors.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63138-3:2022, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for MQ5 series circular connectors with five RF channels, as well as a detailed specification of the blank format. This document also specifies the mating face dimensions and gauging information of MQ5 series circular connectors, and tests selected from IEC 63138-1, applicable to all detail specifications relating to MQ5 series circular connectors.

  • Standard
    57 pages
    English and French language
    sale 15% off

IEC 61169-17:2022, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for series TNC RF coaxial connectors with threaded coupling with a characteristic impedance of 50 Ω.
This document prescribes mating face dimensions for high performance connectors - grade 2, dimensional details of standard test connectors - grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to series TNC RF connectors.
This document indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.

  • Standard
    50 pages
    English and French language
    sale 15% off

IEC 63295:2022 provides the requirements for WB series glass beads with 50 Ω impedance for RF connectors, including, among other, the structure dimensions, IEC type designation, rating and characteristics, and quality assessment. These glass beads are used for the adaption of coaxial systems to microstrip circuits used extensively in microwave communication systems such as TR modules, power modules, integrated circuits where hermetic seal is required.

  • Standard
    33 pages
    English and French language
    sale 15% off

IEC 61169-67:2022, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for series TRL threaded triaxial connectors. Series TRL threaded triaxial connectors with high reliability, small size, good salt characteristics can be connected with symmetrically twisted pair cables or triaxial cables. It has been used in 1553B data bus systems or other communication systems for digital signal transmission.
It specifies mating face dimensions for series TRL threaded triaxial connectors, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to series TRL threaded triaxial connectors.
This specification indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.

  • Standard
    40 pages
    English and French language
    sale 15% off

IEC 61169-68:2022 which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for series TRK bayonet coupling triaxial connectors. The series TRK bayonet coupling triaxial connectors having the advantages of quick connection and separation, high reliability, small size, good salt characteristics, four polarizations to prevent error-mate etc., can be connected to symmetrically twisted pair cables or triaxial cables.
This document indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.

  • Standard
    54 pages
    English and French language
    sale 15% off

IEC 61169-21:2022 which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for type SC threaded RF coaxial connectors with 50 Ω characteristic impedance. The connectors are used with flexible and semi-rigid cables. They are recommended for use in medium power and low reflection applications up to 11 GHz. The dielectric filled interface is especially beneficial in applications involving severe environmental exposure.
This document specifies mating face dimensions, dimensional details, gauging information for general connectors − grade 2 and standard test connectors − grade 0 as well as test schedules and inspection requirements selected from IEC 61169-1, applicable to all detail specifications relating to type SC RF connectors. Type SC interface specified in this document is equivalent to type SC-B interface in IEC 60169-21:1985.
This document indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.

  • Standard
    58 pages
    English and French language
    sale 15% off

IEC 61169-1-6:2022 provides test methods for RF power rating and power handling of RF connectors at specified frequency, temperature and altitude.
This document is applicable to cabled RF connectors, microstrip RF connectors and RF connector adapters. It is also suitable to test RF channels in multi-channel RF connectors and hybrid connectors.

  • Standard
    28 pages
    English and French language
    sale 15% off

This part of IEC 62037 defines the test fixtures and procedures recommended for measuring
levels of passive intermodulation generated by antennas, typically used in wireless
communication systems. The purpose is to define qualification and acceptance test methods for
antennas for use in low intermodulation (low IM) applications

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 62037 deals with the general requirements and measuring methods for
intermodulation (IM) level measurement of passive RF and microwave components, which can
be caused by the presence of two or more transmitting signals.
The test procedures given in this document give the general requirements and measurement
methods required to characterize the level of unwanted IM signals using two transmitting signals.
The IEC 62037 series addresses the measurement of PIM, but does not cover the long-term
reliability of a product with reference to its performance.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 62037 defines test fixtures and procedures recommended for measuring levels
of passive intermodulation generated by filters, typically used in wireless communication
systems. The purpose is to define qualification and acceptance test methods for filters for use
in low intermodulation (low IM) applications

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 62037 defines a procedure to measure levels of passive intermodulation
generated by a coaxial cable assembly.
This test method is applicable to jumper cables, i.e. cable assemblies intended to provide
interface flexibility between rigid devices. It is also used to evaluate cable assemblies that are
subjected to motion in operation

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 62037 defines the impact test on coaxial connectors to evaluate their robustness
against weak connections and particles inside the connector, as independently as possible from
the effects of cable PIM (passive intermodulation).
For other connectors (e.g. panel mounted connectors), the cable can be replaced by an adequate
transmission-line (e.g. airline, stripline). In order to evaluate the effects of mechanical stresses
on the connectors, a series of impacts is applied to the connectors while measuring the PIM.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day