M/116 - CPD: Masonry
Mandate to CEN/CENELEC concerning the execution of standardization work for harmonized standards on masonry and related products
General Information
This document specifies methods for the determination of thermal properties of masonry and masonry products.
- Standard94 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a method for determining the flexural and compressive strength of moulded mortar specimens.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a method for determining the flexural and compressive strength of moulded mortar specimens. This document is applicable to cement/air-lime mortars, air-lime mortars, mortars with hydraulic binders and retarded mortars.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a method for determining the freeze/thaw resistance of clay masonry units in one of
two categories F1 or F2.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a method for determining the freeze/thaw resistance of clay masonry units in one of two categories F1 or F2.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is applicable to factory-made renders and plasters based on organic binders used for external or internal covering on walls, columns, partitions and ceilings. The products are manufactured in paste form, ready to use, or in powder form. This European Standard is also applicable to renders and plasters with inorganic binders such as silicates, silanes, siloxanes and silicones.
Renders and plasters can form the final surface of the structure, textured or not, or they can provide a levelling of the substrate, adequately smooth for subsequent decorative treatments.
This European Standard contains definitions and final performance requirements. It includes relevant characteristic categories to designate renders and plasters.
This European Standard provides for the assessment and verification of constancy of performance (AVCP) of the product to this European Standard. The marking requirement for products covered by this European Standard is included.
This European Standard is not applicable to coating materials and coating systems according to EN 1062-1 and EN 13300.
This European Standard does not contain recommendations for the design and application of renders and plasters. However, this European Standard may be used for definition of renders and plasters in conjunction with codes of application and national specifications for execution of works.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
The ISO 16120 series is applicable to wire rod of non-alloy steel intended for wire drawing and/or cold
rolling. The cross-section can be circular, oval, square, rectangular, hexagonal, octagonal, half-round or
another shape, generally with at least 5 mm nominal dimension, and with a smooth surface.
This document specifies general requirements for non-alloy steel wire rod for conversion to wire. It is
not applicable to products for which standards exist or are in development, for example:
— steel wire rod intended for heat treatment;
— free-cutting steel wire rod;
— steel wire rod for cold heading and cold extrusion;
— steel wire rod intended for the production of electrodes and products for welding;
— steel wire rod for welded fabric for reinforcement for concrete;
— steel wire rod for ball and roller bearings (see ISO 683-17);
— steel wire rod for wire for high fatigue strength mechanical springs, such as valve springs.
In addition to the requirements of this document, the general technical delivery requirements specified
in ISO 404 apply.
- Standard34 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is applicable to factory-made renders and plasters based on organic binders used for external or internal covering on walls, columns, partitions and ceilings. The products are manufactured in paste form, ready to use, or in powder form. This European Standard is also applicable to renders and plasters with inorganic binders such as silicates, silanes, siloxanes and silicones.
Renders and plasters can form the final surface of the structure, textured or not, or they can provide a levelling of the substrate, adequately smooth for subsequent decorative treatments.
This European Standard contains definitions and final performance requirements. It includes relevant characteristic categories to designate renders and plasters.
This European Standard provides for the assessment and verification of constancy of performance (AVCP) of the product to this European Standard. The marking requirement for products covered by this European Standard is included.
This European Standard is not applicable to coating materials and coating systems according to EN 1062-1 and EN 13300.
This European Standard does not contain recommendations for the design and application of renders and plasters. However, this European Standard may be used for definition of renders and plasters in conjunction with codes of application and national specifications for execution of works.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 16120-1:2017 series is applicable to wire rod of non-alloy steel intended for wire drawing and/or cold rolling. The cross-section can be circular, oval, square, rectangular, hexagonal, octagonal, half-round or another shape, generally with at least 5 mm nominal dimension, and with a smooth surface.
ISO 16120-1:2017 specifies general requirements for non-alloy steel wire rod for conversion to wire. It is not applicable to products for which standards exist or are in development, for example:
- steel wire rod intended for heat treatment;
- free-cutting steel wire rod;
- steel wire rod for cold heading and cold extrusion;
- steel wire rod intended for the production of electrodes and products for welding;
- steel wire rod for welded fabric for reinforcement for concrete;
- steel wire rod for ball and roller bearings (see ISO 683‑17);
- steel wire rod for wire for high fatigue strength mechanical springs, such as valve springs.
In addition to the requirements of this document, the general technical delivery requirements specified in ISO 404 apply.
- Standard34 pagesEnglish languagesale 10% offe-Library read for1 day
TC - clarification of Units
- Corrigendum2 pagesEnglish languagesale 10% offe-Library read for1 day
TC - clarification of Units
- Corrigendum2 pagesEnglish languagesale 10% offe-Library read for1 day
TC - clarification of Units
- Corrigendum2 pagesEnglish languagesale 10% offe-Library read for1 day
TC - clarification of Units
- Corrigendum2 pagesEnglish languagesale 10% offe-Library read for1 day
In the masonry unit standards and in national legislation, some properties need to be declared based on a certain fractile and confidence level. To demonstrate compliance with that a statistical tool can be used.
The purpose of this Technical Report is to exemplify how a statistical tool can be used in practice. This document should not contradict nor extend the scope of the work and role of a Notified Body, nor impose additional burdens on the manufacturer, beyond those laid down in the Construction Products Regulation and the product standards.
Mechanical and other properties of building materials and components are in the report described by random variables with a certain type of probability distribution. The popular normal distribution (Laplace-Gauss distribution) is given in Annex A. Normal distribution may be used to approximate many actual symmetrical distributions. When a remarkable asymmetry is observed, then another type of distribution reflecting this asymmetry should be considered, leading to a more complex method to demonstrate compliance with the product standard. More information on the normality test of Shapiro-Wilk is given in Annex D.
- Technical report54 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for factory-made masonry mortars (bedding, jointing and pointing) for use in masonry walls, columns and partitions (e.g. facing and rendered masonry, load bearing or non-load bearing masonry structures for buildings and civil engineering works).
This European Standard defines for fresh mortar the performance related to workable life, chloride content, air content, density and correction time (for thin-layer mortar only). For hardened mortar it defines, e.g. performances related to compressive strength, bond strength, density measured according to the corresponding test methods contained in separate European Standards.
This European Standard provides for the assessment and verification of constancy of performance (AVCP) of the product to this European Standard. The marking requirement for products covered by this European Standard is included.
This European Standard covers masonry mortars defined in Clause 3 with the exception of site made mortar. However, this European Standard or part of this European Standard may be used in conjunction with codes of application and national specifications covering site made mortar.
- Standard28 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is applicable to factory-made rendering/plastering mortars based on inorganic binders for external (rendering) and internal (plastering) use on walls, ceilings, columns and partitions. It contains definitions and final performance requirements.
This European Standard provides for the assessment and verification of constancy of performance (AVCP) of the product to this European Standard. The marking requirement for products covered by this European Standard is included.
It does not cover mortars where calcium sulphate binder is the principal active binding agent.
Calcium sulphate binder can be used as an additional binder together with air lime. If air lime is the principal active binding component, the rendering/plastering mortar is covered by this European Standard. If the calcium sulphate binder is the principal active binding component, the mortar is covered by EN 13279.
Special fire resistant- and acoustical mortars, mortars for structural repair and surface treatments of building elements such as materials for smoothing or trueing, paints, coatings, thin-layer organic renders/plasters and prefabricated units (e.g. plasterboards) are not dealt with in this European Standard.
This European Standard covers rendering/plastering mortars defined in Clause 3 with the exception of site-made rendering/plastering mortars. However, this European Standard or part of this European Standard may be used in conjunction with codes of application and national specifications covering site-made mortar.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
In the masonry unit standards and in national legislation, some properties need to be declared based on a certain fractile and confidence level. To demonstrate compliance with that a statistical tool can be used.
The purpose of this Technical Report is to exemplify how a statistical tool can be used in practice. This document should not contradict nor extend the scope of the work and role of a Notified Body, nor impose additional burdens on the manufacturer, beyond those laid down in the Construction Products Regulation and the product standards.
Mechanical and other properties of building materials and components are in the report described by random variables with a certain type of probability distribution. The popular normal distribution (Laplace-Gauss distribution) is given in Annex A. Normal distribution may be used to approximate many actual symmetrical distributions. When a remarkable asymmetry is observed, then another type of distribution reflecting this asymmetry should be considered, leading to a more complex method to demonstrate compliance with the product standard. More information on the normality test of Shapiro-Wilk is given in Annex D.
- Technical report54 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is applicable to factory-made rendering/plastering mortars based on inorganic binders for external (rendering) and internal (plastering) use on walls, ceilings, columns and partitions. It contains definitions and final performance requirements.
This European Standard provides for the assessment and verification of constancy of performance (AVCP) of the product to this European Standard. The marking requirement for products covered by this European Standard is included.
It does not cover mortars where calcium sulphate binder is the principal active binding agent.
Calcium sulphate binder can be used as an additional binder together with air lime. If air lime is the principal active binding component, the rendering/plastering mortar is covered by this European Standard. If the calcium sulphate binder is the principal active binding component, the mortar is covered by EN 13279.
Special fire resistant- and acoustical mortars, mortars for structural repair and surface treatments of building elements such as materials for smoothing or trueing, paints, coatings, thin-layer organic renders/plasters and prefabricated units (e.g. plasterboards) are not dealt with in this European Standard.
This European Standard covers rendering/plastering mortars defined in Clause 3 with the exception of site-made rendering/plastering mortars. However, this European Standard or part of this European Standard may be used in conjunction with codes of application and national specifications covering site-made mortar.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for factory-made masonry mortars (bedding, jointing and pointing) for use in masonry walls, columns and partitions (e.g. facing and rendered masonry, load bearing or non-load bearing masonry structures for buildings and civil engineering works).
This European Standard defines for fresh mortar the performance related to workable life, chloride content, air content, density and correction time (for thin-layer mortar only). For hardened mortar it defines, e.g. performances related to compressive strength, bond strength, density measured according to the corresponding test methods contained in separate European Standards.
This European Standard provides for the assessment and verification of constancy of performance (AVCP) of the product to this European Standard. The marking requirement for products covered by this European Standard is included.
This European Standard covers masonry mortars defined in Clause 3 with the exception of site made mortar. However, this European Standard or part of this European Standard may be used in conjunction with codes of application and national specifications covering site made mortar.
- Standard28 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for prefabricated lintels for maximum spans of 4,5 m and made from steel, autoclaved aerated concrete, manufactured stone, concrete, fired clay units, calcium silicate units, natural stone units, or a combination of these materials. Concrete and steel beams conforming to EN 1090-1, EN 12602 and EN 13225, as appropriate, are not covered by this standard.
Prefabricated lintels can be either complete lintels or the prefabricated part of a composite lintel.
This European Standard is not applicable to:
a) lintels completely made on site;
b) lintels of which the tensile parts are made on site;
c) timber lintels;
d) natural stone lintels, not reinforced.
Linear components spanning clear openings greater than 4,5 m in masonry walls and linear components intended for use independently in a structural role (e.g. beams) are not covered by this standard.
- Standard43 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements for masonry bed joint reinforcement for structural use (see 5.2.1) and for non-structural use (see 5.2.2).
Where products are intended for use in cavity wall construction, this European Standard covers only the performance of the meshwork as reinforcement in bed joints and not its performance as wall ties across the cavity.
This European Standard is not applicable to:
a) products in the form of individual bars or rods;
b) products formed from materials other than specified grades of austenitic stainless steel, austenitic ferritic stainless steel, zinc pre-coated steel sheet or zinc coated steel wire with or without organic coating.
NOTE Annex ZA refers only to welded wire meshwork intended for structural use referred to in 5.2.1 as there are no known regulated requirements for products of this family for non-structural use.
- Standard28 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for wall ties, tension straps, hangers and brackets for interconnecting masonry and for connecting masonry to other parts of works and buildings including walls, floors, beams, and columns. Where anchors or fasteners are supplied or specified as part of an ancillary component, the requirements including performance requirements apply to the complete product.
This European Standard is not applicable to:
a) anchors and fasteners other than as part of an ancillary component;
b) shelf angles;
c) wall starter plates for tying into existing walls;
d) products formed from materials other than:
1) austenitic stainless steel (molybdenum chrome nickel alloys or chrome nickel alloys);
2) austenitic ferritic stainless steel;
3) ferritic stainless steel;
4) copper;
5) phosphor bronze;
6) aluminium bronze;
7) zinc-coated-steel with or without organic coating;
8) polypropylene;
9) polyamide (for expansion plugs only).
NOTE The resistance to fire performance of the products included herein cannot be assessed separately from the masonry element of which they are part and is therefore not covered under the scope of this part of this European Standard.
- Standard60 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a method for the determination of the adhesive strength between rendering and plastering mortars and a substrate.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements for masonry bed joint reinforcement for structural use (see 5.2.1) and for non-structural use (see 5.2.2).
Where products are intended for use in cavity wall construction, this European Standard covers only the performance of the meshwork as reinforcement in bed joints and not its performance as wall ties across the cavity.
This European Standard is not applicable to:
a) products in the form of individual bars or rods;
b) products formed from materials other than specified grades of austenitic stainless steel, austenitic ferritic stainless steel, zinc pre-coated steel sheet or zinc coated steel wire with or without organic coating.
NOTE Annex ZA refers only to welded wire meshwork intended for structural use referred to in 5.2.1 as there are no known regulated requirements for products of this family for non-structural use.
- Standard28 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for prefabricated lintels for maximum spans of 4,5 m and made from steel, autoclaved aerated concrete, manufactured stone, concrete, fired clay units, calcium silicate units, natural stone units, or a combination of these materials. Concrete and steel beams conforming to EN 1090-1, EN 12602 and EN 13225, as appropriate, are not covered by this standard.
Prefabricated lintels can be either complete lintels or the prefabricated part of a composite lintel.
This European Standard is not applicable to:
a) lintels completely made on site;
b) lintels of which the tensile parts are made on site;
c) timber lintels;
d) natural stone lintels, not reinforced.
Linear components spanning clear openings greater than 4,5 m in masonry walls and linear components intended for use independently in a structural role (e.g. beams) are not covered by this standard.
- Standard43 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for wall ties, tension straps, hangers and brackets for interconnecting masonry and for connecting masonry to other parts of works and buildings including walls, floors, beams, and columns. Where anchors or fasteners are supplied or specified as part of an ancillary component, the requirements including performance requirements apply to the complete product.
This European Standard is not applicable to:
a) anchors and fasteners other than as part of an ancillary component;
b) shelf angles;
c) wall starter plates for tying into existing walls;
d) products formed from materials other than:
1) austenitic stainless steel (molybdenum chrome nickel alloys or chrome nickel alloys);
2) austenitic ferritic stainless steel;
3) ferritic stainless steel;
4) copper;
5) phosphor bronze;
6) aluminium bronze;
7) zinc-coated-steel with or without organic coating;
8) polypropylene;
9) polyamide (for expansion plugs only).
NOTE The resistance to fire performance of the products included herein cannot be assessed separately from the masonry element of which they are part and is therefore not covered under the scope of this part of this European Standard.
- Standard60 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a method for the determination of the adhesive strength between rendering and plastering mortars and a substrate.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a method for determining the active soluble salts content of clay masonry units.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
- Draft10 pagesEnglish languagesale 10% offe-Library read for1 day
This European standard specifies a method for determining the flexural strength of small masonry specimens for the two principal axes of loading. Guidance is given on the preparation of the specimens, the conditioning required before testing, the testing machine, the method of test, the method of calculation and the contents of the test report.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies methods for determining the flexural and shear resistances and load deflection characteristics of single span, single or composite lintels used for supporting uniformly distributed loads over openings in masonry construction.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
- Draft10 pagesEnglish languagesale 10% offe-Library read for1 day
This European standard specifies a method for determining the flexural strength of small masonry specimens for the two principal axes of loading. Guidance is given on the preparation of the specimens, the conditioning required before testing, the testing machine, the method of test, the method of calculation and the contents of the test report.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a method for determining the active soluble salts content of clay masonry units.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
- Draft10 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies methods for determining the flexural and shear resistances and load deflection characteristics of single span, single or composite lintels used for supporting uniformly distributed loads over openings in masonry construction.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
- Draft10 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics and performance requirements of autoclaved aerated concrete (AAC) masonry units for which the main intended uses are different types of load bearing and non-load bearing applications in all forms of walling including single leaf, cavity, partitions, retaining, basement and general use below ground level, including walling for fire protection, thermal insulation, sound insulation and the fabric of chimneys (excluding chimney flue units).
This European Standard includes AAC masonry units with an incorporated insulation not exposed to fire, and masonry units of an overall rectangular parallelepiped shape, specially shaped and accessory units. AAC masonry units may consist of layers of different densities where not all of the layers are loadbearing.
It provides for the assessment and verification of constancy of performance (AVCP) of the product to this European Standard.
The marking requirement for products covered by this European Standard is included.
This European Standard does not cover the requirements for storey height panels, flue linings and masonry units with an incorporated thermal insulation material bonded to the faces of the unit susceptible to be exposed to fire. It does not specify standard sizes for autoclaved aerated concrete units nor standard work dimensions and angles of specially shaped and accessory units. It does not give permissible deviations for specially shaped and accessory units. It does not cover products intended for use as a damp proof course or the lining of a chimney.
- Standard35 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics and performance requirements of calcium silicate masonry units for which the main intended uses are inner walls, outer walls, cellars, foundations and external chimney masonry.
This European Standard is intended to apply to all calcium silicate masonry units, including those of an overall nonrectangular parallelepiped shape, specially shaped and accessory units.
It defines the performance related to e.g. strength, density and dimensional accuracy, measured according to the corresponding test methods contained in separate European Standards.
It provides for the !assessment and verification of constancy of performance (AVCP)" of the product to this European Standard. The marking requirement for products covered by this document is also included.
This European Standard does not specify standard sizes for calcium silicate masonry units, nor standard work dimensions and angles of specially shaped and accessory units.
It does not cover units with more than 60 % volume of voids, nor products made from shale as a major raw material.
It does not cover storey height panels.
It does not cover units intended for use as a damp proof course, nor units with an incorporated thermal insulation material bonded to the faces of the unit susceptible to be exposed to fire, nor chimney flue units.
- Standard45 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics and performance requirements of masonry units manufactured from natural stone the width of which is equal to or greater than 80 mm, for which the main intended uses are common, facing or exposed masonry units in loadbearing or non-loadbearing building and civil engineering applications These units are suitable for all forms of coursed or random masonry walling, including single leaf, cavity, partition, retaining and the external masonry to chimneys. They can provide fire protection, thermal insulation, sound insulation and sound absorption.
This European Standard includes natural stone masonry units of an overall non-rectangular parallelepiped shape, specially shaped and accessory units for internal and external application.
It defines the performance related to e.g. strength, petrographic description, density, porosity, dimensional accuracy, thermal conductivity, water absorption, and frost resistance and provides for the !assessment and verification of constancy of performance (AVCP)" of the product to this European Standard. The marking requirements for products covered by this European Standard are also included.
This European Standard does not cover storey height panels, natural stone for paving, chimney flue linings nor units intended for use as damp proof course.
- Standard34 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics and performance requirements for masonry units manufactured from clay for which the main intended uses are protected or unprotected masonry structure (see definitions 3.3 and 3.4) (e.g. facing and rendered masonry, loadbearing or non-loadbearing masonry structures, including internal linings and partitions, for building and civil engineering).
(...)
This European Standard includes those clay masonry units of an overall non-rectangular parallelepiped shape.
It defines the performance related to e.g. dimensional tolerances, strength, density measured according to the corresponding test methods contained in separate European Standards.
It provides for the assessment and verification of constancy of performance (AVCP) of the product to this European Standard.
The marking requirement for products covered by this European Standard is included.
This European Standard does not specify standard sizes for clay masonry units, nor does it specify standard work dimensions, angles and radii of specially shaped clay masonry units. This European Standard does not include method of measurement of angles and radii characteristics of specially shaped clay masonry units.
This European Standard does not cover requirements for the following: units for paving, flue liners and storey height clay masonry units and clay masonry units with an incorporated thermal insulation material bonded to the faces of the unit susceptible to be exposed to fire. It does, however, include clay masonry units for external chimney masonry.
- Standard57 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics and performance requirements of aggregate concrete masonry units made from dense and lightweight aggregates or a combination of both for which the main intended uses are common, facing or exposed masonry in load bearing or non-load bearing building and civil engineering applications. The units are suitable for all forms of walling, including single leaf, external leaf to chimneys, cavity wall, partitions, retaining, and basement. They can provide fire protection, thermal insulation, sound insulation and sound absorption.
This European Standard includes aggregate concrete masonry units of an overall non-rectangular parallelepiped shape, !specially" shaped and accessory units.
It defines the performance related to e.g. strength, density, dimensional accuracy, and provides for the assessment and verification of constancy of performance (AVCP) of the product to this European Standard. The marking requirement for products covered by this European Standard is included.
This European Standard does not specify standard sizes for aggregate concrete masonry units, nor standard work dimensions and angles of specially shaped aggregate concrete masonry units. It does not cover storey height panels, chimney flue linings nor units intended for use as a damp proof course. It does not cover units with an incorporated thermal insulation material bonded to the faces of the unit susceptible to be exposed to fire.
- Standard41 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics and performance requirements of manufactured stone masonry units for which the main intended uses are facing or exposed masonry in load bearing or non-load bearing building and civil engineering applications. The units are suitable for all forms of coursed or random masonry walling, including single leaf, cavity, partition, retaining and the external masonry to chimneys. They can provide fire protection, thermal insulation, sound insulation and sound absorption. This standard covers concrete masonry units manufactured to resemble natural stone using casting or pressing techniques with or without textured surfaces produced, by casting, splitting, washing, blasting or tooling and with or without variable outline effects. It covers homogeneous masonry units and those consisting of different facing and backing concrete mixes but excludes those manufactured with an adhesive bonded decorative face. This standard does not cover masonry units intended to conform to EN 771-3. It defines the performance related to e.g. strength, density, dimensional accuracy, surface appearance and provides for the evaluation of conformity of the product to this European Standard. The marking requirements for products covered by this European Standard are also included. This European Standard does not apply to storey height panels, masonry units used for chimney flues or units manufactured with an adhesive bonded decorative face. It does not include products intended to be used as a damp proof course nor does it specify standard sizes for manufactured stone masonry units or work dimensions and angles of specially shaped units. It does not cover units with an incorporated thermal insulation material bonded to the faces of the unit susceptible to be exposed to fire.
- Standard35 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics and performance requirements of aggregate concrete masonry units made from dense and lightweight aggregates or a combination of both for which the main intended uses are common, facing or exposed masonry in load bearing or non-load bearing building and civil engineering applications. The units are suitable for all forms of walling, including single leaf, external leaf to chimneys, cavity wall, partitions, retaining, and basement. They can provide fire protection, thermal insulation, sound insulation and sound absorption.
This European Standard includes aggregate concrete masonry units of an overall non-rectangular parallelepiped shape, !specially" shaped and accessory units.
It defines the performance related to e.g. strength, density, dimensional accuracy, and provides for the assessment and verification of constancy of performance (AVCP) of the product to this European Standard. The marking requirement for products covered by this European Standard is included.
This European Standard does not specify standard sizes for aggregate concrete masonry units, nor standard work dimensions and angles of specially shaped aggregate concrete masonry units. It does not cover storey height panels, chimney flue linings nor units intended for use as a damp proof course. It does not cover units with an incorporated thermal insulation material bonded to the faces of the unit susceptible to be exposed to fire.
- Standard41 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics and performance requirements for masonry units manufactured from clay for which the main intended uses are protected or unprotected masonry structure (see definitions 3.3 and 3.4) (e.g. facing and rendered masonry, loadbearing or non-loadbearing masonry structures, including internal linings and partitions, for building and civil engineering).
(...)
This European Standard includes those clay masonry units of an overall non-rectangular parallelepiped shape.
It defines the performance related to e.g. dimensional tolerances, strength, density measured according to the corresponding test methods contained in separate European Standards.
It provides for the assessment and verification of constancy of performance (AVCP) of the product to this European Standard.
The marking requirement for products covered by this European Standard is included.
This European Standard does not specify standard sizes for clay masonry units, nor does it specify standard work dimensions, angles and radii of specially shaped clay masonry units. This European Standard does not include method of measurement of angles and radii characteristics of specially shaped clay masonry units.
This European Standard does not cover requirements for the following: units for paving, flue liners and storey height clay masonry units and clay masonry units with an incorporated thermal insulation material bonded to the faces of the unit susceptible to be exposed to fire. It does, however, include clay masonry units for external chimney masonry.
- Standard57 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics and performance requirements of masonry units manufactured from natural stone the width of which is equal to or greater than 80 mm, for which the main intended uses are common, facing or exposed masonry units in loadbearing or non-loadbearing building and civil engineering applications These units are suitable for all forms of coursed or random masonry walling, including single leaf, cavity, partition, retaining and the external masonry to chimneys. They can provide fire protection, thermal insulation, sound insulation and sound absorption.
This European Standard includes natural stone masonry units of an overall non-rectangular parallelepiped shape, specially shaped and accessory units for internal and external application.
It defines the performance related to e.g. strength, petrographic description, density, porosity, dimensional accuracy, thermal conductivity, water absorption, and frost resistance and provides for the !assessment and verification of constancy of performance (AVCP)" of the product to this European Standard. The marking requirements for products covered by this European Standard are also included.
This European Standard does not cover storey height panels, natural stone for paving, chimney flue linings nor units intended for use as damp proof course.
- Standard34 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics and performance requirements of manufactured stone masonry units for which the main intended uses are facing or exposed masonry in load bearing or non-load bearing building and civil engineering applications. The units are suitable for all forms of coursed or random masonry walling, including single leaf, cavity, partition, retaining and the external masonry to chimneys. They can provide fire protection, thermal insulation, sound insulation and sound absorption. This standard covers concrete masonry units manufactured to resemble natural stone using casting or pressing techniques with or without textured surfaces produced, by casting, splitting, washing, blasting or tooling and with or without variable outline effects. It covers homogeneous masonry units and those consisting of different facing and backing concrete mixes but excludes those manufactured with an adhesive bonded decorative face. This standard does not cover masonry units intended to conform to EN 771-3. It defines the performance related to e.g. strength, density, dimensional accuracy, surface appearance and provides for the evaluation of conformity of the product to this European Standard. The marking requirements for products covered by this European Standard are also included. This European Standard does not apply to storey height panels, masonry units used for chimney flues or units manufactured with an adhesive bonded decorative face. It does not include products intended to be used as a damp proof course nor does it specify standard sizes for manufactured stone masonry units or work dimensions and angles of specially shaped units. It does not cover units with an incorporated thermal insulation material bonded to the faces of the unit susceptible to be exposed to fire.
- Standard35 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics and performance requirements of calcium silicate masonry units for which the main intended uses are inner walls, outer walls, cellars, foundations and external chimney masonry.
This European Standard is intended to apply to all calcium silicate masonry units, including those of an overall nonrectangular parallelepiped shape, specially shaped and accessory units.
It defines the performance related to e.g. strength, density and dimensional accuracy, measured according to the corresponding test methods contained in separate European Standards.
It provides for the !assessment and verification of constancy of performance (AVCP)" of the product to this European Standard. The marking requirement for products covered by this document is also included.
This European Standard does not specify standard sizes for calcium silicate masonry units, nor standard work dimensions and angles of specially shaped and accessory units.
It does not cover units with more than 60 % volume of voids, nor products made from shale as a major raw material.
It does not cover storey height panels.
It does not cover units intended for use as a damp proof course, nor units with an incorporated thermal insulation material bonded to the faces of the unit susceptible to be exposed to fire, nor chimney flue units.
- Standard45 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the characteristics and performance requirements of autoclaved aerated concrete (AAC) masonry units for which the main intended uses are different types of load bearing and non-load bearing applications in all forms of walling including single leaf, cavity, partitions, retaining, basement and general use below ground level, including walling for fire protection, thermal insulation, sound insulation and the fabric of chimneys (excluding chimney flue units).
This European Standard includes AAC masonry units with an incorporated insulation not exposed to fire, and masonry units of an overall rectangular parallelepiped shape, specially shaped and accessory units. AAC masonry units may consist of layers of different densities where not all of the layers are loadbearing.
It provides for the assessment and verification of constancy of performance (AVCP) of the product to this European Standard.
The marking requirement for products covered by this European Standard is included.
This European Standard does not cover the requirements for storey height panels, flue linings and masonry units with an incorporated thermal insulation material bonded to the faces of the unit susceptible to be exposed to fire. It does not specify standard sizes for autoclaved aerated concrete units nor standard work dimensions and angles of specially shaped and accessory units. It does not give permissible deviations for specially shaped and accessory units. It does not cover products intended for use as a damp proof course or the lining of a chimney.
- Standard35 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to Hydraulic binder for non-structural applications in construction used as binder for preparation of mortar for masonry, rendering and plastering and other non structural construction products. This European Standard specifies the definition and composition of Hydraulic binder for non-structural applications (HB). It includes physical, mechanical and chemical requirements and defines strength classes. EN 15368 also states the conformity criteria and the related rules. Necessary durability requirements are also given. Terms of delivery or other contractual conditions, normally included in documents exchanged between the supplier and the purchaser of Hydraulic binder for non-structural applications, are outside the scope of this European Standard.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to Hydraulic binder for non-structural applications in construction used as binder for preparation of mortar for masonry, rendering and plastering and other non structural construction products.
This European Standard specifies the definition and composition of Hydraulic binder for non-structural applications (HB). It includes physical, mechanical and chemical requirements and defines strength classes. EN 15368 also states the conformity criteria and the related rules. Necessary durability requirements are also given.
NOTE For normal applications the information given in this standard, and in the masonry specifications, EN 998-1 and EN 998-2, is generally sufficient. However, in special cases, an exchange of additional information between the producer and user can be helpful. The details of such an exchange are not within the scope of this standard but should be dealt with in accordance with national standards or other regulations or can be agreed between the parties concerned.
Terms of delivery or other contractual conditions, normally included in documents exchanged between the supplier and the purchaser of Hydraulic binder for non-structural applications, are outside the scope of this European Standard.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
To introduce an optional method for testing at zero pre-compression.
- Amendment7 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment8 pagesEnglish languagesale 10% offe-Library read for1 day
To introduce an optional method for testing at zero pre-compression.
- Amendment7 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment8 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies methods for the determination of thermal properties of masonry and masonry products.
- Standard94 pagesEnglish languagesale 10% offe-Library read for1 day