This part of IEC 61076 specifies circular connectors with bayonet locking size B12, B17, B23 and B40, typically used for power, signal and data transmissions in industrial applications.
These connectors consist of fixed and free connectors either rewirable or non-rewirable.
NOTE B indicates that the connector is equipped with bayonet locking, while 12, 17, 23, 40 are the approximate dimensions in millimetres of the contact carrier diameter of these circular connectors.
Power contacts of male connectors are round contacts with Ø 1 mm, Ø 1,5 mm, Ø 1,8 mm, Ø 2,25 mm and Ø 4 mm, with current ratings up to 64 A per pole and rated voltage of 50 V, 300 V or 600 V AC/DC. Power contact groups are classified by type and identified throughout this document as “P” followed by two digits “01” through “09” (see 4.3, Table 1).
Signal contacts of male connectors are round contacts with Ø 1 mm and Ø 1,8 mm, with current ratings up to 20 A per pole and rated voltage of 50 V AC/DC. Signal contact groups are classified by type and identified throughout this document as “S” followed by “0”, “1”, or “2” (see 4.3, Table 2).
Male data contacts are round with Ø 0,8 mm and Ø 1 mm, with current ratings up to 4 A and rated voltage of 50 V AC/DC, Data modules are classified by type and identified throughout this document as “D” followed by “1”, or “2” (see 4.3, Table 3). D1 modules provide data transmission with frequencies from 1 MHz to 100 MHz; D2 modules provide data transmission with frequencies from 0,1 MHz to 600 MHz.
Besides the size of their bayonet locking (B12, B17, B23 or B40), connectors according to this document can be identified by data module (D) and complementing power (P) and signal (S) contact groups and optionally by number of poles, and finally by their application.
These connectors are designated for two main target applications, which differ as follows:
– Application A is for data transmission with power over data.
– Application B is for data transmission without power over data.
Connectors with power, signal and data contacts of the same gender are intended to also transmit power over the data contacts (application A), while connectors with data contacts not of the same gender of power and signal contacts are not intended to transmit power over the data contacts (application B).
The codings provided by this document prevent the mating to any other connector with similarly sized interfaces covered by this document.

  • Standard
    109 pages
    English language
    e-Library read for

This part of IEC 61076-2 covers shielded and unshielded, free and fixed circular connectors without breaking capacity (COC) for power, signal and data transmission, and specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications, respectively.
NOTE 1 As all the connectors described in this document are equipped with shielded data transmission portions, the attribute “shielded” or “unshielded” refers to the additional presence or lack of a shielded connector body.
The connectors described in this document are equipped with an M12, M17, M23 or M40 screw-locking mechanism or a quick-locking mechanism with a size derived from those.
Fixed and rewirable connectors with male or female contacts, mateable with Mxx screw- or quick-locking plugs.
This document provides multiple mating interfaces each of which is associated with a coding preventing the mating of incompatible male and female connectors. The individual codings differ by their numbers of ways, pin layouts and thicknesses, and thus by their power and data transmission capabilities. These codings are referred to as “Type x” where ‘x’ represents an Arabic number.
The connectors described in this document are intended to be used in one-cable automation applications which require various combinations and levels of power up to 600 V AC/ DC and up to 70 A, and either signal or data transmission, or both, with frequencies up to 600 MHz.
NOTE 2 The requirements (or information) described in this document facilitate data transmission through the following Ethernet media systems as defined in IEEE 802.3:
– single-pair Ethernet (10BASE-T1, 100BASE-T1, 1000BASE-T1);
– Fast Ethernet (100BASE-TX);
– Gigabit Ethernet (1000BASE-T);
– 10-gigabit Ethernet (10GBASE-T).

  • Standard
    98 pages
    English language
    e-Library read for

This part of IEC 61076 specifies circular connectors with bayonet locking size B12, B17, B23 and B40, typically used for power, signal and data transmissions in industrial applications. These connectors consist of fixed and free connectors either rewirable or non-rewirable.

  • Standard
    103 pages
    English language
    sale 15% off
  • Standard
    105 pages
    French language
    sale 15% off

IEC 61076-8-110:2026 This part describes free and fixed rectangular connectors, hereinafter referred to as “connector”, with:
2P power plus 2P signal contacts;
- plastic housing with locking lever and four possible codings;
- 300 A rated current, 1 000 V DC rated voltage on the power section;
- 5 A rated current, 50 V DC rated voltage on the signal section;
- individual shielding around each power contact with relevant shielding termination;
- IP65/IP68 degree of protection when mated and locked and IPXXB on both plug and receptacle parts when unmated

  • Standard
    37 pages
    English language
    sale 15% off

IEC 61076-2-117:2026 This part covers shielded and unshielded, free and fixed circular connectors without breaking capacity (COC) for power, signal and data transmission, and specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications, respectively.

  • Standard
    91 pages
    English language
    sale 15% off
  • Standard
    184 pages
    English and French language
    sale 15% off

IEC 61076-2-104:2026 This part of IEC 61076 describes 3-way to 12-way circular connectors with M8 screw-locking or with nominal Æ 8 mm snap-locking, for connection of automation devices, for signal and power transmission up to 50 V AC / 60 V DC rated voltage and up to 4 A rated current.

  • Standard
    60 pages
    English language
    sale 15% off
  • Standard
    62 pages
    French language
    sale 15% off

IEC 61076-2:2025 establishes uniform specifications and technical information for circular connectors.

  • Standard
    30 pages
    English language
    e-Library read for

IEC 60352-7:20205 is applicable to spring clamp connections made with stripped wire of the following types and sizes according to IEC 60228 or IEC 60189-3, without further preparation.

  • Standard
    37 pages
    English language
    sale 15% off
  • Standard
    113 pages
    English language
    sale 15% off
  • Standard
    37 pages
    French language
    sale 15% off
  • Standard
    74 pages
    English and French language
    sale 15% off

IEC 61076-2-111:2025 This part of IEC 61076‑2 describes 4- to 6-way circular connectors with M12 screw-locking with current ratings 8, 12 or 16 A per contact and voltage ratings of 50 V AC / 60 V or 630 V according to their coding, that are typically used for power supply and power applications in industrial premises.

  • Standard
    67 pages
    English language
    sale 15% off
  • Standard
    69 pages
    French language
    sale 15% off
  • Standard
    136 pages
    English and French language
    sale 15% off

IEC 61076-2:2025 establishes uniform specifications and technical information for circular connectors.

  • Standard
    26 pages
    English language
    sale 15% off
  • Standard
    27 pages
    French language
    sale 15% off
  • Standard
    53 pages
    English and French language
    sale 15% off

IEC 63171:2025 is the general requirements and general tests part (general specification) of the whole IEC 63171 series, a set of International Standards covering shielded or unshielded free and fixed connectors for balanced single-pair data transmission with current carrying capacity. It provides the signal integrity requirements, common to the whole series.

  • Standard
    46 pages
    English language
    e-Library read for

IEC 63171:2025 is the general requirements and general tests part (general specification) of the whole IEC 63171 series, a set of International Standards covering shielded or unshielded free and fixed connectors for balanced single-pair data transmission with current carrying capacity. It provides the signal integrity requirements, common to the whole series.

  • Standard
    137 pages
    English language
    sale 15% off
  • Standard
    83 pages
    English and French language
    sale 15% off

IEC 60512-99-002:2021 is used for the assessment of connectors within the scope of SC 48B that are used in twisted pair communication cabling with remote power, such as ISO;IEC 11801 1 Class D, or better, balanced cabling in support of IEEE 802.3btTM (Power over Ethernet, supporting up to 90 W from the power sourcing equipment).
The object of this document is to detail a test schedule to determine the ability of sets of connectors to withstand a minimum of 100 mechanical operations with electrical load, where an electrical current is being passed through the connectors in accordance with IEC 60512 9 3 during the separation (unmating) step. This second edition cancels and replaces the first edition published in 2019. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: Test group UEL has been revised with respect to the order of the test phases, the test severities and the requirements.

  • Standard
    40 pages
    English language
    sale 15% off
  • Standard
    24 pages
    English language
    sale 15% off
  • Standard
    25 pages
    English and French language
    sale 15% off

IEC 61076-8-111:2025 describes 3-pole snap locking rectangular power connectors with IP65/IP67 plastic housing, for rated current of 20 A. It includes overall dimensions, interface dimensions, technical characteristics, performance requirements, and test methods.
The products covered by this detail specification are connectors with breaking capacity (CBC) according to IEC 61984 which are mainly used in AC power conduction, in the field of electrical and electronic equipment.

  • Standard
    31 pages
    English language
    sale 15% off

IEC 61076-8-112:2025 describes 2-pole snap locking rectangular power connectors with IP65/IP67 plastic housing, for rated current of 50 A. It includes overall dimensions, interface dimensions, technical characteristics, performance requirements, test methods.
The products covered by this detail specification are connectors with breaking capacity (CBC) according to IEC 61984 which are mainly used in DC power conduction, in the field of electrical and electronic equipment.

  • Standard
    30 pages
    English language
    sale 15% off

IEC 61076-2-101:2024 describes M12 screw-locking circular connectors with 2-way up to 17‑way, for data transmission with frequencies up to 100 MHz and signal and power transmission at up to 250 V rated voltage and up to 4 A rated current per contact. These connectors consist of fixed and free connectors, either rewirable or non-rewirable. Male connectors have round contacts, Ø 0,6 mm, Ø 0,76 mm, Ø 0,8 mm or Ø 1,0 mm according to number of ways and coding, all contacts with the same size. The different codings prevent the mating of differently coded male and female connectors. This fourth edition cancels and replaces the third edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Technical specifications regarding dimensional information (Clause 5) and characteristics (Clause 6) have been updated, and new subclauses have been added. b) New style NF (free connectors) has been added. c) Fixed connectors with glass to metal seals (former styles WM, XM, YM, ZM and WF, XF, TF and ZF) are no longer covered by this document: relevant definitions and requirements have been removed. d) The P-coding has been eliminated. e) Annex B (informative) Steel conduit thread, sizes has been deleted and a new Annex B (informative) Orientation of cable outlet in relation to coding has been added. f) The dimension specification of former styles AM and BM have been moved into a new Annex C (normative).

  • Standard
    77 pages
    English language
    e-Library read for

IEC 60352-2:2024 is applicable to solderless crimped connections made with: - appropriately designed uninsulated or pre-insulated crimp barrels as parts of crimp contacts, terminal ends or splices, and - stranded wires of 0,05 mm2 to 10 mm2 cross-section or - solid wires of 0,25 mm to 3,6 mm diameter; for use in electrical and electronic equipment. Information on the materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions. This part of IEC 60352 is not applicable to crimping of coaxial cables. This part of IEC 60352 determines the suitability of solderless crimped connections as described above, under specified mechanical, electrical and atmospheric conditions and provides a means of comparing test results when the tools used to make the connections are of different designs or manufacture.

  • Standard
    134 pages
    English language
    e-Library read for

IEC 61076-2-101:2024 describes M12 screw-locking circular connectors with 2-way up to 17‑way, for data transmission with frequencies up to 100 MHz and signal and power transmission at up to 250 V rated voltage and up to 4 A rated current per contact.
These connectors consist of fixed and free connectors, either rewirable or non-rewirable.
Male connectors have round contacts, Ø 0,6 mm, Ø 0,76 mm, Ø 0,8 mm or Ø 1,0 mm according to number of ways and coding, all contacts with the same size.
The different codings prevent the mating of differently coded male and female connectors.
This fourth edition cancels and replaces the third edition published in 2012. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Technical specifications regarding dimensional information (Clause 5) and characteristics (Clause 6) have been updated, and new subclauses have been added.
b) New style NF (free connectors) has been added.
c) Fixed connectors with glass to metal seals (former styles WM, XM, YM, ZM and WF, XF, TF and ZF) are no longer covered by this document: relevant definitions and requirements have been removed.
d) The P-coding has been eliminated.
e) Annex B (informative) Steel conduit thread, sizes has been deleted and a new Annex B (informative) Orientation of cable outlet in relation to coding has been added.
f) The dimension specification of former styles AM and BM have been moved into a new Annex C (normative).

  • Standard
    143 pages
    English and French language
    sale 15% off

IEC 60512-28-100:2024 specifies the test methods for signal integrity and transmission performance for connectors specified in respective parts of IEC 60603-7, IEC61076-1, IEC 61076-2, IEC 61076-3 and IEC 63171 series of standards for connecting hardware applications from 0,1 MHz up to 2 000 MHz, with reference to this document. Note: This document is also suitable for testing signal integrity and transmission performance of connectors up to a lower value of maximum frequency; however, the test methodology specified in the detail specification for any given connector remains the reference conformance test for that connector. The list of connector series of standards does not preclude referencing this document in other connector manufacturer’s specifications or published standards. Test procedures provided herein are: - insertion loss, test 28a; - return loss, test 28b; - near-end crosstalk (NEXT) test 28c; - far-end crosstalk (FEXT), test 28d; - transverse conversion loss (TCL), test 28f; - transverse conversion transfer loss (TCTL), test 28g. Other test procedures referenced herein are: - shield transfer impedance (ZT), see IEC 60512‑26‑100, test 26e. - coupling attenuation (aC), see IEC 62153-4-7 and IEC 62153‑4‑12. - low frequency coupling attenuation (aCLF) see IEC 62153-4-7 and IEC 62153-4-15 This edition includes the following significant technical changes with respect to the previous edition: -The frequency range has been modified to start at 0,1 MHz instead of 1 MHz, to include single-pair connectors. -All tables and requirements have been revised down to 0,1 MHz, and partially improved to reduce the impact of the test fixture. -Formulae to calculate the S-parameters from single-ended parameters have been added. -A note was added for those parameters which are not applicable to single-pair connectors.

  • Standard
    52 pages
    English language
    e-Library read for

IEC 60352-2:2024 is applicable to solderless crimped connections made with:
- appropriately designed uninsulated or pre-insulated crimp barrels as parts of crimp contacts, terminal ends or splices, and
- stranded wires of 0,05 mm2 to 10 mm2 cross-section or
- solid wires of 0,25 mm to 3,6 mm diameter;
for use in electrical and electronic equipment.
Information on the materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions.
This part of IEC 60352 is not applicable to crimping of coaxial cables.
This part of IEC 60352 determines the suitability of solderless crimped connections as described above, under specified mechanical, electrical and atmospheric conditions and provides a means of comparing test results when the tools used to make the connections are of different designs or manufacture.

  • Standard
    260 pages
    English and French language
    sale 15% off

IEC 60512-28-100:2024 specifies the test methods for signal integrity and transmission performance for connectors specified in respective parts of IEC 60603-7, IEC61076-1, IEC 61076-2, IEC 61076-3 and IEC 63171 series of standards for connecting hardware applications from 0,1 MHz up to 2 000 MHz, with reference to this document.
Note: This document is also suitable for testing signal integrity and transmission performance of connectors up to a lower value of maximum frequency; however, the test methodology specified in the detail specification for any given connector remains the reference conformance test for that connector.
The list of connector series of standards does not preclude referencing this document in other connector manufacturer’s specifications or published standards.
Test procedures provided herein are:
- insertion loss, test 28a;
- return loss, test 28b;
- near-end crosstalk (NEXT) test 28c;
- far-end crosstalk (FEXT), test 28d;
- transverse conversion loss (TCL), test 28f;
- transverse conversion transfer loss (TCTL), test 28g.
Other test procedures referenced herein are:
- shield transfer impedance (ZT), see IEC 60512‑26‑100, test 26e.
- coupling attenuation (aC), see IEC 62153-4-7 and IEC 62153‑4‑12.
- low frequency coupling attenuation (aCLF) see IEC 62153-4-7 and IEC 62153-4-15
This edition includes the following significant technical changes with respect to the previous edition:
-The frequency range has been modified to start at 0,1 MHz instead of 1 MHz, to include single-pair connectors.
-All tables and requirements have been revised down to 0,1 MHz, and partially improved to reduce the impact of the test fixture.
-Formulae to calculate the S-parameters from single-ended parameters have been added.
-A note was added for those parameters which are not applicable to single-pair connectors.

  • Standard
    97 pages
    English and French language
    sale 15% off

IEC 63171-1:2024 is part of the IEC 63171 series which is a set of International Standards covering shielded or unshielded free and fixed connectors for balanced single-pair data transmission with current carrying capacity.
IEC 63171 is the general requirements and tests part (general specifications) of the whole series. Subsequent parts, such as this Part 1, are product detail specifications of the series IEC 63171 and do not duplicate information given in IEC 63171, but list only additional requirements. Each subsequent part is identified by a type of connector covered with the same number identifying the part. Some parts can describe more embodiments, with different connectors geometries (rectangular, circular), sharing the core element and the relevant features.
This part of IEC 63171 covers two-way, shielded or unshielded, free and fixed connectors known as Type 1, for balanced single-pair data transmission with frequencies up to 600 MHz and with current carrying capacity up to 2,0 A at 60 °C.
It specifies the common dimensions, and provides the mechanical, electrical, signal integrity, and environmental characteristics, the reliability specifications and corresponding tests for these connectors.
For the complete specifications regarding a connector of this series, both the general specification and the relevant detail specification are therefore required.
For the qualification of a connector of this series, both the general specification and the relevant detail specification shall be met.
This second edition cancels and replaces the first edition published in 2020. This edition constitutes a technical revision and includes the following significant technical changes with respect to the previous edition:
* Information on obtaining a license agreement was updated.
* Connector characteristics and test requirements were aligned with IEC 63171:2021 where applicable.
* Added requirements for Polarizing method (5.6.4) and Dynamic stress (5.6.5) to align with IEC 63171:2021.
* Added test group BP - Moisture (6.7.3.4) to align with IEC 63171:2021.

  • Standard
    21 pages
    English language
    sale 15% off
  • Standard
    22 pages
    French language
    sale 15% off

IEC 60352-9:2024 provides guidelines for welding and testing of ultrasonically welded connections and includes requirements, tests and practical guidance information. Ultrasonic welding is a form of cold friction welding that is becoming increasingly popular in many industries. This type of welding uses ultrasonic vibration to join materials together, creating a bond that is both strong and reliable. Ultrasonic welding has been identified as a process in ISO 4063-41 by the International Organization for Standardization (ISO). The process of ultrasonic welding relies on high frequency ultrasound waves being used to create frictional heat at the connection point. High temperature is not required for this special method of welding, making it one of the most cost-effective ways to join two materials together. It also requires fewer steps than traditional methods, meaning it can be completed quickly and with minimal resources. Ultrasonic welding has been around for decades but only recently has become more widely utilized due to advances in technology and its availability at lower cost. It can be used on many different materials including plastics, rubbers, metals, textiles, and composites. Due to its precision and strong bonds it creates, it has become extremely popular in manufacturing processes such as automotive industry, electronics industry, furniture production and even medical device production. This document covers ultrasonically welded connections made with stranded or flexible wires (class 2, 5 or 6 per IEC 60228) of copper or copper alloy, as well as of aluminium or aluminium alloy. These welded metal-to-metal connections shall employ wires with cross-sectional area of 0,08 mm2 to 160 mm2 and shall not exceed a total cross-sectional area, in case of wire bundle, of 200 mm2. For aluminium or aluminium alloy wires, the minimum required cross-sectional area is 2,5 mm2. Additionally, information on materials, data from industrial experience and test procedures are included to ensure electrically stable connections under prescribed environmental conditions. Lastly, this document aims to achieve comparable results when using ultrasonic welding equipment with similar performance and specifications as specified by the termination manufacturer.

  • Standard
    71 pages
    English language
    e-Library read for

IEC 60352-9:2024 provides guidelines for welding and testing of ultrasonically welded connections and includes requirements, tests and practical guidance information.
Ultrasonic welding is a form of cold friction welding that is becoming increasingly popular in many industries. This type of welding uses ultrasonic vibration to join materials together, creating a bond that is both strong and reliable. Ultrasonic welding has been identified as a process in ISO 4063-41 by the International Organization for Standardization (ISO).
The process of ultrasonic welding relies on high frequency ultrasound waves being used to create frictional heat at the connection point. High temperature is not required for this special method of welding, making it one of the most cost-effective ways to join two materials together.
It also requires fewer steps than traditional methods, meaning it can be completed quickly and with minimal resources.
Ultrasonic welding has been around for decades but only recently has become more widely utilized due to advances in technology and its availability at lower cost. It can be used on many different materials including plastics, rubbers, metals, textiles, and composites. Due to its precision and strong bonds it creates, it has become extremely popular in manufacturing processes such as automotive industry, electronics industry, furniture production and even medical device production.
This document covers ultrasonically welded connections made with stranded or flexible wires (class 2, 5 or 6 per IEC 60228) of copper or copper alloy, as well as of aluminium or aluminium alloy. These welded metal-to-metal connections shall employ wires with cross-sectional area of 0,08 mm2 to 160 mm2 and shall not exceed a total cross-sectional area, in case of wire bundle, of 200 mm2. For aluminium or aluminium alloy wires, the minimum required cross-sectional area is 2,5 mm2.
Additionally, information on materials, data from industrial experience and test procedures are included to ensure electrically stable connections under prescribed environmental conditions.
Lastly, this document aims to achieve comparable results when using ultrasonic welding equipment with similar performance and specifications as specified by the termination manufacturer.

  • Standard
    138 pages
    English and French language
    sale 15% off

This part of IEC 61969 specifies a set of basic environmental requirements and tests, as well as safety aspects for outdoor enclosures for electrical and electronic equipment, under conditions of non-weatherprotected locations above ground. The purpose of this document is to define a minimum level of environmental performance in order to meet requirements of storage, transport and final installation. The intention is to establish basic environmental performance criteria for outdoor enclosure compliance.

  • Standard
    21 pages
    English language
    e-Library read for

IEC 61969-3:2023 specifies a set of basic environmental requirements and tests, as well as safety aspects for outdoor enclosures for electrical and electronic equipment, under conditions of non-weatherprotected locations above ground. The purpose of this document is to define a minimum level of environmental performance in order to meet requirements of storage, transport and final installation. The intention is to establish basic environmental performance criteria for outdoor enclosure compliance.

  • Standard
    54 pages
    English language
    sale 15% off
  • Standard
    33 pages
    English and French language
    sale 15% off

IEC 60512-99-003:2023 is used for the assessment of connectors within the scope of SC 48B that are used in balanced single-pair communication cabling with remote power, in support of e.g., IEEE 802.3 remote powering applications for point-to-point connections. The object of this document is to detail a test schedule to determine the ability of sets of single-pair connectors as defined in the IEC 63171 series to withstand a minimum of 100 mechanical operations with electrical load, where an electrical current is being passed through the connector in accordance with IEC 60512-9-3 during the separation (unmating) step. This document does not cover multidrop powering applications of single-pair connectors.

  • Standard
    20 pages
    English language
    e-Library read for

IEC 60512-99-003:2023 is used for the assessment of connectors within the scope of SC 48B that are used in balanced single-pair communication cabling with remote power, in support of e.g., IEEE 802.3 remote powering applications for point-to-point connections.
The object of this document is to detail a test schedule to determine the ability of sets of single-pair connectors as defined in the IEC 63171 series to withstand a minimum of 100 mechanical operations with electrical load, where an electrical current is being passed through the connector in accordance with IEC 60512-9-3 during the separation (unmating) step.
This document does not cover multidrop powering applications of single-pair connectors.

  • Standard
    32 pages
    English and French language
    sale 15% off

IEC 61076-8-105:2023 applies to free and fixed 2-pole snap locking rectangular power connectors with plastic housing with rated current 63 A and rated voltage up to 400 V. It includes overall dimensions, interface dimensions, technical characteristics, performance requirements, test methods.

  • Standard
    59 pages
    English and French language
    sale 15% off

IEC 61076-3-106:2023 constitutes a detail product specification for 8-way connectors for data transmission with frequencies up to 600 MHz.
It covers protective housings for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in the IEC 60603-7 series to IP65/IP67 rating according to IEC 60529, for use in industrial environments.
The housings cover a variety of different locking mechanisms according to this document and a variety of different mounting configurations and termination types which are detailed in the IEC 60603-7 series.
Common mating configurations for all variants are defined in IEC 60603-7. The mating dimensions for the housings under Clause 3 allow the mating conditions under IEC 60603-7 to be fulfilled.
The fully assembled variants (connectors) described in this document incorporate fully compliant IEC 60603-7 series fixed and free connectors.

  • Standard
    74 pages
    English and French language
    sale 15% off

IEC 61076-8-106: 2023 applies to free and fixed, 2-pole push-pull and snap locking power rectangular connectors with fuses, with rated voltage of 400 V DC and rated current of 16 A. It includes overall dimensions, interface dimensions, technical characteristics, performance requirements, and test methods.
Connectors according to this document are connectors with breaking capacity (CBC) according to IEC 61984 which are mainly used in DC power conduction, in the field of electrical and electronic equipment.

  • Standard
    65 pages
    English and French language
    sale 15% off

IEC 61076-2-115:2023 describes free and fixed 12P shielded circular connectors with 2 A rated current, rated voltage up to and including 50 V AC/DC, IP65/IP67 metal housing with push-pull locking (hereinafter referred to as a connectors) for use in electrical and electronic equipment. It includes overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.

  • Standard
    39 pages
    English language
    e-Library read for

IEC 63171-7:2023 covers shielded free and fixed circular connectors with 4 ways up to 7 ways for power and data transmission and specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications respectively.
The connectors described in this document are either equipped with an M12 screw-locking mechanism (styles with M12 in the name) or a quick-locking push-pull mechanism with a size derived from that (styles with P12 in the name) or both mechanisms combined (styles with C12 in the name). For the sake of simplicity, the connectors' size is denoted as "size 12" in this document.
This document provides multiple mating interfaces each of which is associated with a coding preventing the mating of incompatible male and female connectors. These codings are referred to as "Type x", where "x" is represented by a Roman numeral.
For all codings, two ways and the additional shield pin, which is intended to be connected to the cable screen, support differential data transmission with frequencies up to 600 MHz by meeting the requirements of Category B, as defined in IEC 63171.

  • Standard
    33 pages
    English language
    sale 15% off

IEC 61076-2-115:2023 describes free and fixed 12P shielded circular connectors with 2 A rated current, rated voltage up to and including 50 V AC/DC, IP65/IP67 metal housing with push-pull locking (hereinafter referred to as a connectors) for use in electrical and electronic equipment. It includes overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.

  • Standard
    68 pages
    English and French language
    sale 15% off

IEC 61076-8-107:2023 describes free and fixed rectangular connectors with:
- 2P power plus 2P signal contacts;
- plastic housing with locking lever and four possible codings;
- 200 A rated current, 1 000 V DC rated voltage on the power section;
- 5 A rated current, 50 V DC rated voltage on the signal section;
- individual shielding around each power contact with relevant shielding termination;
- IP65/IP68 degree of protection when mated and locked, and IPXXB on both plug and receptacle parts when unmated;
- hereinafter referred to as a connector, for use in electrical and electronic equipment, including overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.

  • Standard
    75 pages
    English and French language
    sale 15% off

IEC 61076-8-109:2023 describes free and fixed rectangular connectors with:
- 2P power plus 2P signal contacts;
- plastic housing with locking lever and four possible codings;
- 130 A rated current, 1 000 V DC rated voltage on the power section;
- 5 A rated current, 50 V DC rated voltage on the signal section;
- individual shielding around each power contact with relevant shielding termination;
- IP65/IP68 degree of protection when mated and locked and IPXXB on both plug, and receptacle parts when unmated;
- hereinafter referred to as a connector, for use in electrical and electronic equipment, including overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.

  • Standard
    75 pages
    English and French language
    sale 15% off

IEC 61076-8-104:2023 describes free and fixed 2-pole circular power connectors with 40 A rated current, rated voltage up to and including 50 V AC/DC, and push-pull locking IP65/IP67 metal housings (hereinafter referred to as connectors) for use in electrical and electronic equipment. It includes overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.

  • Standard
    67 pages
    English and French language
    sale 15% off

IEC 61076-8-103:2023 describes free and fixed 2-pole power (1P+N) plus PE circular connectors with 20 A rated current, rated voltage up to and including 300 V AC, IP65/IP67 metal housing with push-pull locking (hereinafter referred to as a connectors) for use in electrical and electronic equipment. It includes overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.

  • Standard
    68 pages
    English and French language
    sale 15% off

IEC 61076-8-108:2023 describes free and fixed rectangular connectors with:
- 2P power plus 2P signal contacts;
- plastic housing with locking lever and four possible codings;
- 250 A rated current, 1 000 V DC rated voltage on the power section;
- 5 A rated current, 50 V DC rated voltage on the signal section;
- individual shielding around each power contact with relevant shielding termination;
- IP65/IP68 degree of protection when mated and locked, and IPXXB on both plug and receptacle parts when unmated, hereinafter referred to as a connector, for use in electrical and electronic equipment, including overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.

  • Standard
    74 pages
    English and French language
    sale 15% off

This part of IEC 61969 contains design guidelines for outdoor enclosures for electrical and electronic equipment and is applicable over a wide field of mechanical, electromechanical and electronic equipment and its installation where a modular design is used. The objectives of this document are: - to provide an overview of specifications for enclosures focused on requirements for outdoor applications for stationary use at non-weather protected locations, and - to achieve product integrity under outdoor conditions and to ease product selection for the sourcing of outdoor enclosures from different vendors. These enclosures are considered to contain any equipment and provide protection for the outdoor installed facilities against unwanted environmental impacts. The installed equipment can be, but is not limited to, subracks or chassis according to IEC 60917 (all parts) or IEC 60297 (all parts). A typical outdoor enclosure is shown in Figure 1. [Figure 1]

  • Standard
    18 pages
    English language
    e-Library read for

IEC 61076-3-126:2023 covers 5-pole rectangular connectors for electric power supply up to 16 A per pole. These connectors consist of fixed and free connectors, both either rewirable or non-rewirable. This document employs the general function principles of the push-pull connector housing system described in IEC 61076‑3‑117 with IP65/IP67 degree of protection according to IEC 60529 for harsh applications. Male connectors have pin contacts with square cross-section with 1 mm side. Connectors according to this document are without breaking capacity COC according to IEC 61984, therefore they are not intended to be engaged or disengaged in normal use when live or under load.

  • Standard
    49 pages
    English language
    e-Library read for

IEC 61969-1:2023 contains design guidelines for outdoor enclosures for electrical and electronic equipment and is applicable over a wide field of mechanical, electromechanical and electronic equipment and its installation where a modular design is used. The objectives of this document are:
- to provide an overview of specifications for enclosures focused on requirements for outdoor applications for stationary use at non-weatherprotected locations, and
- to achieve product integrity under outdoor conditions and to ease product selection for the sourcing of outdoor enclosures from different vendors.

  • Standard
    40 pages
    English language
    sale 15% off
  • Standard
    25 pages
    English and French language
    sale 15% off

CORRECTED VERSION 2025-11
IEC 60297-3-1:2023 provides information on the technological schemes of the IEC 60297 series and shows how to apply the 19-inch series standards for the mechanical structure practices for electrical and electronic equipment.
The content of the corrigendum 1 (2025-11) has been included in this copy.

  • Technical report
    34 pages
    English language
    sale 15% off

IEC 61076-3-126:2023 covers 5-pole rectangular connectors for electric power supply up to 16 A per pole. These connectors consist of fixed and free connectors, both either rewirable or non-rewirable. This document employs the general function principles of the push-pull connector housing system described in IEC 61076‑3‑117 with IP65/IP67 degree of protection according to IEC 60529 for harsh applications.
Male connectors have pin contacts with square cross-section with 1 mm side. Connectors according to this document are without breaking capacity COC according to IEC 61984, therefore they are not intended to be engaged or disengaged in normal use when live or under load.

  • Standard
    84 pages
    English and French language
    sale 15% off

IEC 61076-2-116:2022 specifies circular connectors size 15 with bayonet-locking, with up to 3 power contacts with rated insulation voltage up to 630 V AC/DC and rated current up to 20 A, plus PE, and up to 3 auxiliary contacts with rated insulation voltage up to 63 V AC/DC and rated current up to 10 A, that are typically used for industrial power supply and power applications, such as the feeding and control of 3-phase asynchronous motors. These connectors consist of both fixed and free connectors either rewireable or non-rewireable, with bayonet-locking. Male connectors have round contacts, either power or signal, Ø1,6 mm.

  • Standard
    48 pages
    English language
    e-Library read for

IEC 60352-6:2022 This part of IEC 60352 is applicable to insulation piercing connections made with stranded wires and tinsel wires, insulated flat conductors and flat flexible circuitries for use in electrical and electronic equipment. Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under prescribed environmental conditions. The object of this document is to:  
determine the suitability of insulation piercing connections under specified mechanical, electrical, and atmospheric conditions;
provide a means of comparing test results when the tools used to make the connections, if any, are of different designs or manufacture.

  • Standard
    38 pages
    English language
    e-Library read for

Frequently Asked Questions

TC 48 is a Technical Committee within the International Electrotechnical Commission (IEC). It is named "Electrical connectors and mechanical structures for electrical and electronic equipment" and is responsible for: Standardization of electric connectors, connecting devices and mechanical structures for electronic and electrical equipment. Note 1: RF connectors will not be dealt with by the technical committee as they will be covered by TC 46 together with RF cables. However, hybrid connectors, which employ RF contacts, will be handled by TC 48. They will use the appropriate test methods, terminology etc. defined by TC 46 and TC 86 documents. Note 2 : Sockets for components shall be considered in co-operation with the relevant technical committee. Note 3 : Safety requirements for areas already dealt with by other committees will not be developed by this technical committee. This committee has published 776 standards.

TC 48 develops IEC standards. The scope of work includes: Standardization of electric connectors, connecting devices and mechanical structures for electronic and electrical equipment. Note 1: RF connectors will not be dealt with by the technical committee as they will be covered by TC 46 together with RF cables. However, hybrid connectors, which employ RF contacts, will be handled by TC 48. They will use the appropriate test methods, terminology etc. defined by TC 46 and TC 86 documents. Note 2 : Sockets for components shall be considered in co-operation with the relevant technical committee. Note 3 : Safety requirements for areas already dealt with by other committees will not be developed by this technical committee. Currently, there are 776 published standards from this technical committee.

The International Electrotechnical Commission (IEC) is the world's leading organization for the preparation and publication of international standards for electrical, electronic, and related technologies. Founded in 1906, the IEC provides a global platform for companies, industries, and governments to meet, discuss, and develop the international standards they require.

A Technical Committee (TC) in IEC is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.