EN IEC 61076-2-116:2023
(Main)Connectors for electrical and electronic equipment - Product requirements - Part 2 -116: Detail specification for circular connectors size 15 with up to 3+PE power contacts and auxiliary contacts, with bayonet-locking
Connectors for electrical and electronic equipment - Product requirements - Part 2 -116: Detail specification for circular connectors size 15 with up to 3+PE power contacts and auxiliary contacts, with bayonet-locking
IEC 61076-2-116:2022 specifies circular connectors size 15 with bayonet-locking, with up to 3 power contacts with rated insulation voltage up to 630 V AC/DC and rated current up to 20 A, plus PE, and up to 3 auxiliary contacts with rated insulation voltage up to 63 V AC/DC and rated current up to 10 A, that are typically used for industrial power supply and power applications, such as the feeding and control of 3-phase asynchronous motors. These connectors consist of both fixed and free connectors either rewireable or non-rewireable, with bayonet-locking. Male connectors have round contacts, either power or signal, Ø1,6 mm.
Steckverbinder für elektrische und elektronische Geräte - Produktanforderungen - Teil 2-116: Einzelspezifikation für Rundsteckverbinder der Größe 15 mit bis zu 3+PE-Leistungskontakten und Hilfskontakten, mit Bajonettverriegelung
Connecteurs pour équipements électriques et électroniques - Exigences de produit - Partie 2-116: Spécification particulière pour les connecteurs circulaires de taille 15 avec jusqu’à 3+PE contacts de puissance et contacts auxiliaires, avec verrouillage à baïonnette
IEC 61076-2-116:2022 spécifie les connecteurs circulaires de taille 15 avec verrouillage à baïonnette, avec jusqu’à 3 contacts de puissance avec une tension assignée d’isolement jusqu’à 630 V CA/CC et un courant assigné jusqu’à 20 A, plus PE, et jusqu’à 3 contacts auxiliaires avec tension assignée d’isolement jusqu’à 63 V CA/CC et courant assigné jusqu’à 10 A, qui sont généralement utilisés pour les applications d’alimentation industrielle et d’énergie telles que l’alimentation et la commande de moteurs asynchrones triphasés. Ces connecteurs se composent à la fois d’embases et de fiches, démontables ou non démontables, avec un verrouillage à baïonnette. Les connecteurs mâles, que ce soit pour l’alimentation ou pour le signal, ont des contacts ronds de Ø 1,6 mm.
Konektorji za električno in elektronsko opremo - Zahteve za izdelek - 2-116. del: Podrobna specifikacija za okrogle konektorje velikosti 15 z do 3+PE tokovnimi in pomožnimi kontakti z bajonetnim zaklepom (IEC 61076-2-116:2022)
Standard IEC 61076-2-116:2022 določa okrogle konektorje velikosti 15 z bajonetnim zapiranjem, z do tremi napajalnimi kontakti z nazivno izolacijsko napetostjo do 630 V AC/DC in nazivnim tokom do 20 A, plus PE, ter do tremi pomožnimi kontakti z nazivno izolacijsko napetostjo do 63 V izmenični/enosmerni tok in nazivnim tokom do 10 A, ki se običajno uporabljajo za industrijsko napajanje in pogon sisteme, kot sta napajanje in krmiljenje trifaznih asinhronskih motorjev. Ti konektorji so sestavljeni iz pritrjenih in prostih konektorjev z možnostjo ponovnega ožičenja ali brez, z bajonetnim zaklepanjem. Moški konektorji imajo okrogle kontakte, energetske ali signalne, Ø1,6 mm.
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
01-april-2023
Konektorji za električno in elektronsko opremo - Zahteve za izdelek - 2-116. del:
Podrobna specifikacija za okrogle konektorje velikosti 15 z do 3+PE tokovnimi in
pomožnimi kontakti z bajonetnim zaklepom (IEC 61076-2-116:2022)
Connectors for electrical and electronic equipment - Product requirements - Part 2-116:
Detail specification for circular connectors size 15 with up to 3+PE power contacts and
auxiliary contacts, with bayonet-locking (IEC 61076-2-116:2022)
Steckverbinder für elektrische und elektronische Geräte - Produktanforderungen - Teil 2-
116: Einzelspezifikation für Rundsteckverbinder der Größe 15 mit bis zu 3+PE-
Leistungskontakten und Hilfskontakten, mit Bajonettverriegelung (IEC 61076-2-
116:2022)
Connecteurs pour équipements électriques et électroniques - Exigences de produit -
Partie 2-116: Spécification particulière pour les connecteurs circulaires de taille 15 avec
jusqu’à 3+PE contacts de puissance et contacts auxiliaires, avec verrouillage à
baïonnette (IEC 61076-2-116:2022)
Ta slovenski standard je istoveten z: EN IEC 61076-2-116:2023
ICS:
31.220.10 Vtiči in vtičnice, konektorji Plug-and-socket devices.
Connectors
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD EN IEC 61076-2-116
NORME EUROPÉENNE
EUROPÄISCHE NORM January 2023
ICS 31.220.10
English Version
Connectors for electrical and electronic equipment - Product
requirements - Part 2 -116: Detail specification for circular
connectors size 15 with up to 3+PE power contacts and auxiliary
contacts, with bayonet-locking
(IEC 61076-2-116:2022)
Connecteurs pour équipements électriques et électroniques Steckverbinder für elektrische und elektronische Geräte -
- Exigences de produit - Partie 2-116: Spécification Produktanforderungen - Teil 2-116: Einzelspezifikation für
particulière pour les connecteurs circulaires de taille 15 Rundsteckverbinder der Größe 15 mit bis zu 3+PE-
avec jusqu'à 3+PE contacts de puissance et contacts Leistungskontakten und Hilfskontakten, mit
auxiliaires, avec verrouillage à baïonnette Bajonettverriegelung
(IEC 61076-2-116:2022) (IEC 61076-2-116:2022)
This European Standard was approved by CENELEC on 2023-01-19. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Türkiye and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2023 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 61076-2-116:2023 E
European foreword
The text of document 48B/3000/FDIS, future edition 1 of IEC 61076-2-116, prepared by SC 48B
"Electrical connectors" of IEC/TC 48 "Electrical connectors and mechanical structures for electrical
and electronic equipment" was submitted to the IEC-CENELEC parallel vote and approved by
CENELEC as EN IEC 61076-2-116:2023.
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2023-10-19
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2026-01-19
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Any feedback and questions on this document should be directed to the users’ national committee. A
complete listing of these bodies can be found on the CENELEC website.
Endorsement notice
The text of the International Standard IEC 61076-2-116:2022 was approved by CENELEC as a
European Standard without any modification.
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1 Where an International Publication has been modified by common modifications, indicated by (mod),
the relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available
here: www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 60050-581 - International Electrotechnical Vocabulary - - -
Part 581: Electromechanical components for
electronic equipment
IEC 60068-1 - Environmental testing - Part 1: General and EN 60068-1 -
guidance
IEC 60068-2-60 - Environmental testing - Part 2-60: Tests - EN 60068-2-60 -
Test Ke: Flowing mixed gas corrosion test
IEC 60352 series Solderless connections EN 60352 series
IEC 60512-1 - Connectors for electrical and electronic EN IEC 60512-1 -
equipment - Tests and measurements - Part
1: Generic specification
IEC 60512-1-1 - Connectors for electronic equipment - Tests EN 60512-1-1 -
and measurements - Part 1-1: General
examination - Test 1a: Visual examination
IEC 60512-1-2 - Connectors for electronic equipment - Tests EN 60512-1-2 -
and measurements - Part 1-2: General
examination - Test 1b: Examination of
dimension and mass
IEC 60512-2-1 - Connectors for electronic equipment - Tests EN 60512-2-1 -
and measurements - Part 2-1: Electrical
continuity and contact resistance tests - Test
2a: Contact resistance - Millivolt level method
IEC 60512-2-5 - Connectors for electronic equipment - Tests EN 60512-2-5 -
and measurements - Part 2-5: Electrical
continuity and contact resistance tests - Test
2e: Contact disturbance
IEC 60512-3-1 - Connectors for electronic equipment - Tests EN 60512-3-1 -
and measurements - Part 3-1: Insulation
tests - Test 3a: Insulation resistance
IEC 60512-4-1 - Connectors for electronic equipment - Tests EN 60512-4-1 -
and measurements - Part 4-1: Voltage stress
tests - Test 4a: Voltage proof
Publication Year Title EN/HD Year
IEC 60512-5-1 - Connectors for electronic equipment - Tests EN 60512-5-1 -
and measurements - Part 5-1: Current-
carrying capacity tests - Test 5a:
Temperature rise
IEC 60512-5-2 - Connectors for electronic equipment - Tests EN 60512-5-2 -
and measurements - Part 5-2: Current-
carrying capacity tests - Test 5b: Current-
temperature derating
IEC 60512-6-3 - Connectors for electronic equipment - Tests EN 60512-6-3 -
and measurements - Part 6-3: Dynamic
stress tests - Test 6c: Shock
IEC 60512-6-4 - Connectors for electronic equipment - Tests EN 60512-6-4 -
and measurements - Part 6-4: Dynamic
stress tests - Test 6d: Vibration (sinusoidal)
IEC 60512-9-1 - Connectors for electronic equipment - Tests EN 60512-9-1 -
and measurements - Part 9-1: Endurance
tests - Test 9a: Mechanical operation
IEC 60512-9-2 - Connectors for electronic equipment - Tests EN 60512-9-2 -
and measurements - Part 9-2: Endurance
tests - Test 9b: Electrical load and
temperature
IEC 60512-11-1 - Connectors for electrical and electronic EN IEC 60512-11-1 -
equipment - Tests and measurements - Part
11-1: Climatic tests - Test 11a - Climatic
sequence
IEC 60512-11-4 - Connectors for electronic equipment - Tests EN 60512-11-4 -
and measurements - Part 11-4: Climatic tests
- Test 11d: Rapid change of temperature
IEC 60512-11-7 - Connectors for electronic equipment - Tests EN 60512-11-7 -
and measurements - Part 11-7: Climatic tests
- Test 11g: Flowing mixed gas corrosion test
IEC 60512-11-9 - Connectors for electronic equipment - Tests EN 60512-11-9 -
and measurements - Part 11-9: Climatic tests
- Test 11i: Dry heat
IEC 60512-11-10 - Connectors for electronic equipment - Tests EN 60512-11-10 -
and measurements - Part 11-10: Climatic
tests - Test 11j: Cold
IEC 60512-11-12 - Connectors for electronic equipment - Tests EN 60512-11-12 -
and measurements - Part 11-12: Climatic
tests - Test 11m: Damp heat, cyclic
IEC 60512-13-2 - Connectors for electronic equipment - Tests EN 60512-13-2 -
and measurements - Part 13-2: Mechanical
operation tests - Test 13b: Insertion and
withdrawal forces
IEC 60512-13-5 - Connectors for electronic equipment - Tests EN 60512-13-5 -
and measurements - Part 13-5: Mechanical
operation tests - Test 13e: Polarizing and
keying method
Publication Year Title EN/HD Year
IEC 60512-16-1 - Connectors for electronic equipment - Tests EN 60512-16-1 -
and measurements - Part 16-1: Mechanical
tests on contacts and terminations - Test
16a: Probe damage
IEC 60512-16-5 - Connectors for electronic equipment - Tests EN 60512-16-5 -
and measurements - Part 16-5: Mechanical
tests on contacts and terminations - Test
16e: Gauge retention force (resilient
contacts)
IEC 60512-19-3 - Electromechanical components for electronic EN 60512-19-3 -
equipment - Basic testing procedures and
measuring methods - Part 19: Chemical
resistance tests - Section 3: Test 19c - Fluid
resistance
IEC 60529 1989 Degrees of protection provided by enclosures EN 60529 1991
(IP Code)
+ A1 1999 + A1 2000
+ A2 2013 + A2 2013
IEC 60664-1 - Insulation coordination for equipment within EN IEC 60664-1 -
low-voltage supply systems - Part 1:
Principles, requirements and tests
IEC 60999-1 - Connecting devices - Electrical copper EN 60999-1 -
conductors - Safety requirements for screw-
type and screwless-type clamping units - Part
1: General requirements and particular
requirements for clamping units for
conductors from 0,2 mm2 up to 35 mm2
(included)
IEC 61076-1 2006 Connectors for electronic equipment - EN 61076-1 2006
Product requirements - Part 1: Generic
specification
+ A1 2019 + A1 2019
IEC 61984 - Connectors - Safety requirements and tests EN 61984 -
IEC 62197-1 - Connectors for electronic equipment - Quality EN 62197-1 -
assessment requirements - Part 1: Generic
specification
ISO 11469 - Plastics - Generic identification and marking EN ISO 11469 -
of plastics products
ISO 21920-1 2021 Geometrical product specifications (GPS) - EN ISO 21920-1 2022
Surface texture: Profile - Part 1: Indication of
surface texture
IEC 61076-2-116 ®
Edition 1.0 2022-12
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Connectors for electrical and electronic equipment – Product requirements –
Part 2-116: Detail specification for circular connectors size 15 with up to 3+PE
power contacts and auxiliary contacts, with bayonet-locking
Connecteurs pour équipements électriques et électroniques – Exigences de
produit –
Partie 2-116: Spécification particulière pour les connecteurs circulaires de taille
15 avec jusqu’à 3+PE contacts de puissance et contacts auxiliaires, avec
verrouillage à baïonnette
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 31.220.10 ISBN 978-2-8322-6057-9
– 2 – IEC 61076-2-116:2022 © IEC 2022
CONTENTS
FOREWORD . 5
INTRODUCTION . 7
1 Scope . 8
2 Normative references . 8
3 Terms and definitions . 10
4 Technical information . 10
4.1 Recommended method of termination . 10
4.2 Electrical ratings and characteristics . 11
4.3 Current-carrying capacity . 11
4.4 Systems of levels – Compatibility levels, according to IEC 61076-1 . 11
4.5 Classification into climatic categories . 11
4.6 Marking . 11
4.7 Safety aspects . 11
5 Dimensional information . 12
5.1 General . 12
5.2 Survey of styles and variants . 12
5.2.1 General . 12
5.2.2 Fixed connectors . 12
5.2.3 Free connectors . 15
5.2.4 Interface dimensions . 21
5.3 Engagement (mating) information . 28
5.4 Gauges – Sizing gauges and retention force gauges . 29
6 Characteristics . 30
6.1 General . 30
6.2 Contact assignment and other definitions . 30
6.3 Classification into climatic category . 30
6.4 Electrical characteristics . 31
6.4.1 Rated voltage – Rated impulse voltage – Pollution degree . 31
6.4.2 Voltage proof . 31
6.4.3 Creepage and clearance distances . 31
6.4.4 Current-carrying capacity . 32
6.4.5 Contact resistance . 32
6.4.6 Insulation resistance. 32
6.5 Mechanical characteristics . 32
6.5.1 Mechanical operation . 32
6.5.2 Insertion and withdrawal forces . 33
6.5.3 Polarizing method . 33
6.6 Other characteristics . 33
6.6.1 Vibration (sinusoidal) . 33
6.6.2 Shock . 34
6.6.3 Degree of protection provided by enclosures (IP code) . 34
6.6.4 Screen and shielding properties . 34
6.7 Environmental aspects – Marking of insulation material (plastics) . 34
7 Test schedules . 34
7.1 General . 34
7.1.1 Overview . 34
IEC 61076-2-116:2022 © IEC 2022 – 3 –
7.1.2 Climatic category . 34
7.1.3 Creepage and clearance distances . 34
7.1.4 Arrangement for contact resistance measurements . 35
7.1.5 Arrangement for dynamic stress tests (vibration and shock) . 35
7.2 Basic (minimum) test schedule. 36
7.3 Full test schedule . 36
7.3.1 General . 36
7.3.2 Test group P – Preliminary . 37
7.3.3 Test group AP – Dynamic/ Climatic . 37
7.3.4 Test group BP – Mechanical endurance . 40
7.3.5 Test group CP – Electrical load . 41
7.3.6 Test group DP – Chemical resistivity . 42
7.3.7 Test group EP – Connection method tests . 42
Annex A (informative) Orientation of cable outlet in relation to coding . 43
Figure 1 – Fixed connector, male contacts, with a square flange front mounting . 13
Figure 2 – Fixed connector, male contacts, single hole mounting . 13
Figure 3 – Fixed connector, male contacts, single hole mounting, circular mounting
orientation . 14
Figure 4 – Fixed connector, female contacts, with a square flange front mounting . 14
Figure 5 – Fixed connector, female contacts, single hole mounting . 15
Figure 6 – Fixed connector, female contacts, single hole mounting, circular mounting
orientation . 15
Figure 7 – Rewireable connector, male contacts, straight version . 16
Figure 8 – Rewireable connector, male contacts, right angled version . 17
Figure 9 – Non-rewirable connector, male contacts, straight version . 17
Figure 10 – Non-rewirable connector, male contacts, right-angled version . 18
Figure 11 – Rewireable connector, female contacts, straight version . 19
Figure 12 – Rewireable connector, female contacts, right angled version . 19
Figure 13 – Non-rewirable connector, female contacts, straight version . 20
Figure 14 – Non-rewirable connector, female contacts, right-angled version . 21
Figure 15 – Type 1 – Male side . 22
Figure 16 – Type 2 – Male side . 24
Figure 17 – Type 3 – Male side . 26
Figure 18 – Engagement (mating) information . 28
Figure 19 – Gauge dimensions . 30
Figure 20 – Contact resistance arrangement . 35
Figure 21 – Dynamic stress test arrangement . 36
Figure A.1 – Orientation of cable outlet in relation to the coding – Free male
connectors according to Table 9 . 43
Table 1 – Ratings of connectors . 11
Table 2 – Styles of fixed connectors . 12
Table 3 – Dimensions of style DM, Figure 1 . 13
Table 4 – Dimensions of style EM, Figure 2 . 13
Table 5 – Dimensions of style FM, Figure 3 . 14
– 4 – IEC 61076-2-116:2022 © IEC 2022
Table 6 – Dimensions of style DF, Figure 4 . 14
Table 7 – Dimensions of style EF, Figure 5 . 15
Table 8 – Dimensions of style FF, Figure 6 . 15
Table 9 – Styles of free connectors . 16
Table 10 – Dimensions of style JM, Figure 7 . 16
Table 11 – Dimensions of style KM, Figure 8 . 17
Table 12 – Dimensions of style LM, Figure 9 . 18
Table 13 – Dimensions of style MM, Figure 10 . 18
Table 14 – Dimensions of style JF, Figure 11 . 19
Table 15 – Dimensions of style KF, Figure 12 . 20
Table 16 – Dimensions of style LF, Figure 13 . 20
Table 17 – Dimensions of style MF, Figure 14 . 21
Table 18 – Dimensions for Figure 15. 23
Table 19 – Dimensions for Figure 16. 25
Table 20 – Dimensions for Figure 17. 27
Table 21 – Connectors dimensions in mated and locked position . 29
Table 22 – Gauges . 30
Table 23 – Climatic category . 30
Table 24 – Rated insulation voltage – Rated impulse voltage – Voltage proof . 31
Table 25 – Voltage proof . 31
Table 26 – Creepage and clearance distances . 32
Table 27 – Number of mechanical operations . 33
Table 28 – Insertion and withdrawal forces . 33
Table 29 – Polarizing insertion forces . 33
Table 30 – Number of test specimens . 37
Table 31 – Test group P . 37
Table 32 – Test group AP . 38
Table 33 – Test group BP . 40
Table 34 – Test group CP . 41
Table 35 – Test group DP . 42
Table 36 – Test group EP . 42
IEC 61076-2-116:2022 © IEC 2022 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
CONNECTORS FOR ELECTRICAL AND ELECTRONIC
EQUIPMENT – PRODUCT REQUIREMENTS –
Part 2-116: Detail specification for circular connectors
size 15 with up to 3+PE power contacts and auxiliary
contacts, with bayonet-locking
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence between
any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent
rights. IEC shall not be held responsible for identifying any or all such patent rights.
IEC 61076-2-116 has been prepared by subcommittee 48B: Electrical connectors, of IEC
technical committee 48: Electrical connectors and mechanical structures for electrical and
electronic equipment. It is an International Standard.
The text of this International Standard is based on the following documents:
Draft Report on voting
48B/3000/FDIS 48B/3010/RVD
Full information on the voting for its approval can be found in the report on voting indicated in
the above table.
The language used for the development of this International Standard is English.
– 6 – IEC 61076-2-116:2022 © IEC 2022
This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in
accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, available
at www.iec.ch/members_experts/refdocs. The main document types developed by IEC are
described in greater detail at www.iec.ch/standardsdev/publications.
A list of all parts in the IEC 61076 series, published under the general title Connectors for
electrical and electronic equipment – Product requirements, can be found on the IEC website.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under webstore.iec.ch in the data related to the
specific document. At this date, the document will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IEC 61076-2-116:2022 © IEC 2022 – 7 –
INTRODUCTION
IEC SC 48B – Electrical connectors
Specification available from:
IEC 61076-2-116 Ed. 1
IEC General secretariat
or from the addresses shown on the inside cover.
DETAIL SPECIFICATION in accordance with IEC 61076-1
Circular connectors for signal and
power applications with bayonet-
locking
Male and female connectors
Male and female contacts
Rewireable and non-rewireable
Free cable connectors
Straight and right-angle connectors
Fixed connectors
Flange mounting
Single hole mounting
With circular mounting orientation
The International Electrotechnical Commission (IEC) draws attention to the fact that it is claimed
that compliance with this document may involve the use of a patent concerning the connector
type 3 given in 5.2.4.3.
IEC takes no position concerning the evidence, validity and scope of this patent right. The
holder of this patent right has assured the IEC that he/she is willing to negotiate licences either
free of charge or under reasonable and non-discriminatory terms and conditions with applicants
throughout the world. In this respect, the statement of the holder of this patent right is registered
with IEC.
Information may be obtained from:
LQ Mechatronik-Systeme GmbH
Carl-Benz-Strasse 6
Besigheim, Germany 74354
Attn: Mr. Friedrich P. Link
ISO (www.iso.org/patents) and IEC (http://patents.iec.ch) maintain on-line data bases of
patents relevant to their standards. Users are encouraged to consult the data bases for the
most up to date information concerning patents.
– 8 – IEC 61076-2-116:2022 © IEC 2022
CONNECTORS FOR ELECTRICAL AND ELECTRONIC
EQUIPMENT – PRODUCT REQUIREMENTS –
Part 2-116: Detail specification for circular connectors
size 15 with up to 3+PE power contacts and auxiliary
contacts, with bayonet-locking
1 Scope
This part of IEC 61076-2 specifies circular connectors size 15 with bayonet-locking, with up to
3 power contacts with rated insulation voltage up to 630 V AC/DC and rated current up to 20 A,
plus PE, and up to 3 auxiliary contacts with rated insulation voltage up to 63 V AC/DC and rated
current up to 10 A, that are typically used for industrial power supply and power applications,
such as the feeding and control of 3-phase asynchronous motors. These connectors consist of
both fixed and free connectors either rewireable or non-rewireable, with bayonet-locking. Male
connectors have round contacts, either power or signal, Ø1,6 mm.
NOTE 1 Size 15 is the dimension of the inner contact carrier of the male connector interface (dimension AG in
Table 18).
NOTE 2 Number of power and auxiliary contacts, voltage and current ratings vary according to the type of connector,
see Table 1.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies.
For undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60050-581, International Electrotechnical Vocabulary (IEV) – Part 581: Electromechanical
components for electronic equipment
IEC 60068-1, Environmental testing – Part 1: General and guidance
IEC 60068-2-60, Environmental testing – Part 2-60: Tests – Test Ke: Flowing mixed gas
corrosion test
IEC 60352 (all parts), Solderless connections
IEC 60512-1, Connectors for electrical and electronic equipment – Tests and measurements –
Part 1: Generic specification
IEC 60512-1-1, Connectors for electronic equipment – Tests and measurements – Part 1-1:
General examination – Test 1a: Visual examination
IEC 60512-1-2, Connectors for electronic equipment – Tests and measurements – Part 1-2:
General examination – Test 1b: Examination of dimension and mass
IEC 60512-2-1, Connectors for electronic equipment – Tests and measurements – Part 2-1:
Electrical continuity and contact resistance tests – Test 2a: Contact resistance – Millivolt level
method
IEC 61076-2-116:2022 © IEC 2022 – 9 –
IEC 60512-2-5, Connectors for electronic equipment – Tests and measurements – Part 2-5:
Electrical continuity and contact resistance tests – Test 2e: Contact disturbance
IEC 60512-3-1, Connectors for electronic equipment – Tests and measurements – Part 3-1:
Insulation tests – Test 3a: Insulation resistance
IEC 60512-4-1, Connectors for electronic equipment – Tests and measurements – Part 4-1:
Voltage stress tests – Test 4a: Voltage proof
IEC 60512-5-1, Connectors for electronic equipment – Tests and measurements – Part 5-1:
Current-carrying capacity tests – Test 5a: Temperature rise
IEC 60512-5-2, Connectors for electronic equipment – Tests and measurements – Part 5-2:
Current-carrying capacity tests – Test 5b: Current-temperature derating
IEC 60512-6-3, Connectors for electronic equipment – Tests and measurements – Part 6-3:
Dynamic stress tests – Test 6c: Shock
IEC 60512-6-4, Connectors for electronic equipment – Tests and measurements – Part 6-4:
Dynamic stress tests – Test 6d: Vibration (sinusoidal)
IEC 60512-9-1, Connectors for electronic equipment – Tests and measurements – Part 9-1:
Endurance tests – Test 9a: Mechanical operation
IEC 60512-9-2, Connectors for electronic equipment – Tests and measurements – Part 9-2:
Endurance tests – Test 9b: Electrical load and temperature
IEC 60512-11-1, Connectors for electrical and electronic equipment – Tests and measurements
– Part 11-1: Climatic tests – Test 11a – Climatic sequence
IEC 60512-11-4, Connectors for electronic equipment – Tests and measurements – Part 11-4:
Climatic tests – Test 11d: Rapid change of temperature
IEC 60512-11-7, Connectors for electronic equipment – Tests and measurements – Part 11-7:
Climatic tests – Test 11g: Flowing mixed gas corrosion test
IEC 60512-11-9, Connectors for electronic equipment – Tests and measurements – Part 11-9:
Climatic tests – Test 11i: Dry heat
IEC 60512-11-10, Connectors for electronic equipment – Tests and measurements –
Part 11-10: Climatic tests – Test 11j: Cold
IEC 60512-11-12, Connectors for electronic equipment – Tests and measurements –
Part 11-12: Climatic tests – Test 11m: Damp heat, cyclic
IEC 60512-13-2, Connectors for electronic equipment – Tests and measurements – Part 13-2:
Mechanical operation tests – Test 13b: Insertion and withdrawal forces
IEC 60512-13-5, Connectors for electronic equipment – Tests and measurements – Part 13-5:
Mechanical operation tests – Test 13e: Polarizing and keying method
IEC 60512-16-1, Connectors for electronic equipment – Tests and measurements – Part 16-1:
Mechanical tests on contacts and terminations – Test 16a: Probe damage
– 10 – IEC 61076-2-116:2022 © IEC 2022
IEC 60512-16-5, Connectors for electronic equipment – Tests and measurements – Part 16-5:
Mechanical tests on contacts and terminations – Test 16e: Gauge retention force (resilient
contacts)
IEC 60512-19-3, Electromechanical components for electronic equipment – Basic testing
procedures and measuring methods – Part 19: Chemical resistance tests – Section 3: Test 19c
– Fluid resistance
IEC 60529:1989, Degrees of protection provided by enclosures (IP Code)
IEC 60529:1989/AMD1:1999
IEC 60529:1989/AMD2:2013
IEC 60664-1, Insulation coordination for equipment within low-voltage systems – Part 1:
Principles, requirements and tests
IEC 60999-1, Connecting devices – Electrical copper conductors – Safety requirements for
screw-type and screwless-type clamping units – Part 1: General requirements and particular
requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included)
IEC 61076-1:2006, Connectors for electronic equipment – Product requirements – Part 1:
Generic specification
IEC 61076-1:2006/AMD1:2019
IEC 61984, Connectors – Safety requirements and tests
IEC 62197-1, Connectors for electronic equipment – Quality assessment requirements – Part 1:
Generic specification
ISO 11469, Plastics – Generic identification and marking of plastics products
ISO 21920-1: 2021, Geometrical product specifications (GPS) – Surface texture: Profile –
Part 1: Indication of surface texture
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 60050-581,
IEC 61076-1, IEC 60512-1, IEC 61984, as well as the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following
addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
3.1
circular mounting orientation
circular mounting position of the connector in relation to the polarization of the mating interface
Note 1 to entry: Where the free connector has an angled cable entry (as opposed to a straight cable entry), the
angle between the cable entry direction and the polarization keyway should be specified.
4 Technical information
4.1 Recommended method of termination
According to IEC 60352 series (solderless connections) and IEC 60999-1 (screw-type and
screwless-type connections).
IEC 61076-2-116:2022 © IEC 2022 – 11 –
4.2 Electrical ratings and characteristics
The electrical ratings and characteristics shall be as specified in Table 1 and in Table 22
through Table 25.
Table 1 – Ratings of connectors
Rated
No. of Pin Ø Rated insulation
current
Type Style Function
contacts mm voltage
A
3 2 + PE 24 V DC 20
6-way
1 1,6
(2 +PE +3) 3 A + B + C 24 V DC 4
3 2 + PE 48 V DC 20
6-way
2 1,6
(2 +PE +3) 3 A + B + C 48 V DC 4
6-way 4 3 + PE 630 V AC/DC 16
3 1,6
(3 +PE +2) 2 A + B 63 V AC/DC 10
NOTE 1 The rated currents for connectors type 1 and 2 provided in Table 1 are associated with a min. 2,5 mm
wire size for the power contacts and a min. 0,34 mm wire size for the auxiliary contacts.
NOTE 2 The rated currents for connectors type 3 provided in Table 1 are associated with a min. 1,5 mm wire
size for the power contacts and a min. 1 mm wire size for the auxiliary contacts.
4.3 Current-carrying capacity
The current-carrying capacity shall be measured according to IEC 60512-5-2, Test 5b and
stated by the manufacturer.
It shall be applied to a wiring with conductor cross-sectional area of min. 1,5 mm for 16 A or
2 2 2
min. 2,5 mm for 20 A on the power section and min. 0,34 mm for 4 A or 1 mm for 10 A on
the signal section, and it shall fulfil the rated currents specified in Table 1.
4.4 Systems of levels – Compatibility levels, according to IEC 61076-1
Connectors according to this document are intermateable according to IEC 61076-1.
4.5 Classification into climatic categories
Classification into climatic categories is specified in 6.3.
4.6 Marking
The marking of the connector and the package shall be in accordance with 2.7 of
IEC 61076-1:2006.
4.7 Safety aspects
For safety aspects IEC 61984 shall be considered.
Connectors according to this document are COC (connectors without breaking capacity) per
IEC 61984, unless otherwise specified by the manufacturer.
-----------
...








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...