IEC 60352-7:2020 is available as IEC 60352-7:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60352-7:2020 is applicable to spring clamp connections made with stripped wire without further preparation:
- solid conductors of 0,32 mm to 3,7 mm nominal diameter (0,08 mm2 to 10 mm2 cross‑section), or
- stranded conductors of 0,08 mm2 to 10 mm2 cross-section, or
- flexible conductors of 0,0...
view more

    • sale 15% off
    • Standard
      30 pages
      English language

IEC 60603-7:2020 is available as IEC 60603-7:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60603-7:2020 covers 8-way, unshielded, free and fixed connectors and is intended to specify the common dimensions (interface dimensions), mechanical, electrical and environmental characteristics and tests for the family of IEC 60603-7-x connectors. These connectors are intermateable (according to...view more

    • sale 10% off
    • Standard
      58 pages
      English language
    • e-Library read for
      1 day

IEC 61076-2-114:2020 describes circular connectors with M8 screw locking typically used for data and power transmissions in industrial applications. These connectors consist of fixed and free connectors that are either rewireable or non-rewireable. Data transmission performance is for Category 5 up to 100 MHz. Two coded versions, identified as D-coded and P-coded, are provided that differ by their pin size and optionally by number of poles, hence by the function provided for field applications. ...view more

    • sale 10% off
    • Standard
      51 pages
      English language
    • e-Library read for
      1 day

IEC 60603-7:2020 is available as IEC 60603-7:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60603-7:2020 covers 8-way, unshielded, free and fixed connectors and is intended to specify the common dimensions (interface dimensions), mechanical, electrical and environmental characteristics and tests for the family of IEC 60603-7-x connectors. These connectors are intermateable (according to...view more

    • sale 15% off
    • Standard
      107 pages
      English and French language

IEC 61076-2-114:2020 describes circular connectors with M8 screw locking typically used for data and power transmissions in industrial applications. These connectors consist of fixed and free connectors that are either rewireable or non-rewireable. Data transmission performance is for Category 5 up to 100 MHz.
Two coded versions, identified as D-coded and P-coded, are provided that differ by their pin size and optionally by number of poles, hence by the function provided for field applications....
view more

    • sale 15% off
    • Standard
      93 pages
      English and French language

This part of IEC 61076 specifies circular connectors with an inner push‑pull locking
mechanism of a size derived from and thus being compatible with M12 screw‑locking
connectors and with mating interfaces according to IEC 61076‑2‑101, IEC 61076‑2‑109,
IEC 61076‑2‑111 and IEC 61076‑2‑113.
A female fixed connector with inner push-pull locking according to this document is
intermateable with a correspondingly coded male free connector with M12 screw-locking
according to IEC 61076-2-101, IEC 6...
view more

    • sale 10% off
    • Standard
      65 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60352 is applicable to solderless press-in connections for use in electrical
and electronic equipment and components.
The press-in connection consists of a termination having a suitable press-in zone which is
inserted into a hole of a board.
Information on materials and data from industrial experience is included in addition to the test
procedures to provide electrically stable connections under specified environmental conditions.
The object of this document is to determin...
view more

    • sale 10% off
    • Standard
      38 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60512, when required by the detail product specification, is used for testing
connectors or solderless connections within the scope of technical committee 48. It may also be
used for similar devices when specified in a detail product specification.
The object of this document is to detail a standard method for subjecting solderless
connections to thermal stress conditioning by cyclic current loading.

    • sale 10% off
    • Standard
      14 pages
      English language
    • e-Library read for
      1 day

IEC 61076-2-012:2020 specifies circular connectors with an inner push‑pull locking mechanism of a size derived from and thus being compatible with M12 screw‑locking connectors and with mating interfaces according to IEC 61076‑2‑101, IEC 61076‑2‑109, IEC 61076‑2‑111 and IEC 61076‑2‑113.
A female fixed connector with inner push-pull locking according to this document is intermateable with a correspondingly coded male free connector with M12 screw-locking according to IEC 61076-2-101, IEC 61076-2-...
view more

    • sale 15% off
    • Standard
      121 pages
      English and French language

IEC 60352-5:2020 is applicable to solderless press-in connections for use in electrical and electronic equipment and components.
The press-in connection consists of a termination having a suitable press-in zone which is inserted into a hole of a board.
Information on materials and data from industrial experience is included in addition to the test procedures to provide electrically stable connections under specified environmental conditions.
The object of this document is to determine the sui...
view more

    • sale 15% off
    • Standard
      69 pages
      English and French language
    • sale 15% off
    • Standard
      34 pages
      English language

IEC PAS 61076-2-010:2020 specifies circular connectors with a push-pull locking mechanism of a size derived from and thus being compatible with M12 screw-locking connectors (free connectors with screw-locking according to IEC 61076-2-101, IEC 61076-2-109, IEC 61076­2­111 or IEC 61076-2-113 are compatible to push-pull fixed interfaces according to this document) and with mating interfaces according to IEC 61076-2-101, IEC 61076-2-109, IEC 61076-2-111 or IEC 61076-2-113.

    • sale 15% off
    • Technical specification
      41 pages
      English language

This part of IEC 63171 covers two-way, shielded or unshielded, free and fixed connectors for
data transmission with frequencies up to 600 MHz and with current carrying capacity up
to 2,0 A at 60 °C. It is intended to specify the common dimensions, mechanical, electrical,
signal integrity, environmental characteristics, reliability specifications and corresponding
tests for these connectors.

    • sale 10% off
    • Standard
      35 pages
      English language
    • e-Library read for
      1 day

This part of IEC 62343 provides a performance specification template for wavelength selective
switches. The object is to provide a framework for the preparation of detail specifications on the
performance of wavelength selective switches.
Additional specification parameters are often included for detailed product specifications or
performance specifications if necessary. However, specification parameters specified in this
document are not removed from the detail product specifications or pe...
view more

    • sale 10% off
    • Standard
      17 pages
      English language
    • e-Library read for
      1 day

This part of IEC 61076 describes 2-pole or 3-pole power plus 2-pole signal shielded and
sealed connectors with plastic housing (hereinafter referred to as a connector) for electrical
and electronic equipment, including overall dimensions, interface dimensions, technical
characteristics, performance requirements and test methods.
This document is applicable to electrical connectors with sealing and shielding requirements
meeting this document, with a rated voltage up to and including 750 V a...
view more

    • sale 10% off
    • Standard
      45 pages
      English language
    • e-Library read for
      1 day

This part of IEC 61076 describes 2-pole or 3-pole power plus 2-pole signal shielded and
sealed connectors with plastic housing (hereinafter referred to as a connector) for electrical
and electronic equipment, including overall dimensions, interface dimensions, technical
characteristics, performance requirements and test methods.
This document is applicable to electrical connectors with sealing and shielding requirements
meeting this document, with a rated voltage up to and including 750 V a...
view more

    • sale 10% off
    • Standard
      44 pages
      English language
    • e-Library read for
      1 day

This part of IEC 61076 describes 2-pole or 3-pole power plus 2-pole signal shielded and
sealed connectors with plastic housing (hereinafter referred to as a connector) for electrical
and electronic equipment, including overall dimensions, interface dimensions, technical
characteristics, performance requirements and test methods.
This document is applicable to electrical connectors with sealing and shielding requirements
meeting this document, with a rated voltage up to and including 750 V a...
view more

    • sale 10% off
    • Standard
      45 pages
      English language
    • e-Library read for
      1 day

IEC 60512-9-5:2020 is available as IEC 60512-9-5:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60512-9-5:2020 when required by the detail product specification, is used for testing connectors or solderless connections within the scope of technical committee 48. It may also be used for similar devices when specified in a detail product specification. The object of this document is t...
view more

    • sale 15% off
    • Standard
      21 pages
      English and French language

IEC 63171-6:2020, covers 2-way and 4-way (data/power) shielded free and fixed connectors for data transmission with frequencies up to 600 MHz and specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications respectively. This document specifies several properties overlapping with specifications in the IEC 63171 series which have been drafted later. In case of conflict the specifications within this document...view more

    • sale 10% off
    • Standard
      54 pages
      English language
    • e-Library read for
      1 day

NEXT ACTION: PUBLICATION EXPECTED BY 2020-05-15

    • sale 10% off
    • Amendment
      12 pages
      English language
    • e-Library read for
      1 day