WG 5 - Test methods
- Abstract
To standardize test procedures for electrical connectors and
electrical devices.
To prepare 60512-23-7, 60512-25-5, 60512-25-7, 60512-25-9 and 60512-26-100 standards- Slovenian
Test methods
Normaliser les procédures d'essai pour les connecteurs
électriques et les dispositifs électriques.
IEC 60512-99-002:2021 is used for the assessment of connectors within the scope of SC 48B that are used in twisted pair communication cabling with remote power, such as ISO;IEC 11801 1 Class D, or better, balanced cabling in support of IEEE 802.3btTM (Power over Ethernet, supporting up to 90 W from the power sourcing equipment).
The object of this document is to detail a test schedule to determine the ability of sets of connectors to withstand a minimum of 100 mechanical operations with electrical load, where an electrical current is being passed through the connectors in accordance with IEC 60512 9 3 during the separation (unmating) step. This second edition cancels and replaces the first edition published in 2019. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: Test group UEL has been revised with respect to the order of the test phases, the test severities and the requirements.
- Standard40 pagesEnglish languagesale 15% off
- Standard24 pagesEnglish languagesale 15% off
- Standard25 pagesEnglish and French languagesale 15% off
IEC 60512-28-100:2024 specifies the test methods for signal integrity and transmission performance for connectors specified in respective parts of IEC 60603-7, IEC61076-1, IEC 61076-2, IEC 61076-3 and IEC 63171 series of standards for connecting hardware applications from 0,1 MHz up to 2 000 MHz, with reference to this document.
Note: This document is also suitable for testing signal integrity and transmission performance of connectors up to a lower value of maximum frequency; however, the test methodology specified in the detail specification for any given connector remains the reference conformance test for that connector.
The list of connector series of standards does not preclude referencing this document in other connector manufacturer’s specifications or published standards.
Test procedures provided herein are:
- insertion loss, test 28a;
- return loss, test 28b;
- near-end crosstalk (NEXT) test 28c;
- far-end crosstalk (FEXT), test 28d;
- transverse conversion loss (TCL), test 28f;
- transverse conversion transfer loss (TCTL), test 28g.
Other test procedures referenced herein are:
- shield transfer impedance (ZT), see IEC 60512‑26‑100, test 26e.
- coupling attenuation (aC), see IEC 62153-4-7 and IEC 62153‑4‑12.
- low frequency coupling attenuation (aCLF) see IEC 62153-4-7 and IEC 62153-4-15
This edition includes the following significant technical changes with respect to the previous edition:
-The frequency range has been modified to start at 0,1 MHz instead of 1 MHz, to include single-pair connectors.
-All tables and requirements have been revised down to 0,1 MHz, and partially improved to reduce the impact of the test fixture.
-Formulae to calculate the S-parameters from single-ended parameters have been added.
-A note was added for those parameters which are not applicable to single-pair connectors.
- Standard97 pagesEnglish and French languagesale 15% off
IEC 60512-99-003:2023 is used for the assessment of connectors within the scope of SC 48B that are used in balanced single-pair communication cabling with remote power, in support of e.g., IEEE 802.3 remote powering applications for point-to-point connections.
The object of this document is to detail a test schedule to determine the ability of sets of single-pair connectors as defined in the IEC 63171 series to withstand a minimum of 100 mechanical operations with electrical load, where an electrical current is being passed through the connector in accordance with IEC 60512-9-3 during the separation (unmating) step.
This document does not cover multidrop powering applications of single-pair connectors.
- Standard32 pagesEnglish and French languagesale 15% off
L'IEC 60512-27-200:2022 est avant tout destiné à être utilisé pour les essais d’intégrité des signaux et de qualité de la transmission jusqu’à 2 000 MHz des types de connecteurs à 8 voies couverts par la série IEC 60603-7 (IEC 60603‑7‑81), conformément à la méthode d’essai des connecteurs de l’IEC 60512‑28‑100. Le présent document couvre les connecteurs d’essai ainsi que les dispositifs d’essai à référence indirecte utilisés pour mesurer l’intégrité des signaux et la qualité de la transmission selon les exigences de la série IEC 60603-7 concernant les types de connecteurs à 8 voies définis dans les normes publiées suivantes: - IEC 60603‑7‑2 - IEC 60603‑7‑3 - IEC 60603‑7‑4 - IEC 60603‑7‑5 - IEC 60603‑7‑41 - IEC 60603‑7‑51 - IEC 60603‑7‑81 Le présent document fournit des informations supplémentaires sur les connecteurs d’essai ainsi que sur les dispositifs d’essai utilisés pour les mesures de performance des connecteurs conformément aux normes de méthode d’essai qui concernent ces connecteurs: - IEC 60512‑26‑100 - IEC 60512‑27‑100 - IEC 60512‑28‑100 Cette première édition annule et la CEI/PAS 60512-27-200, parue en 2018.
- Standard59 pagesEnglish and French languagesale 15% off
IEC 60512-9-5:2020 when required by the detail product specification, is used for testing connectors or solderless connections within the scope of technical committee 48. It may also be used for similar devices when specified in a detail product specification. The object of this document is to detail a standard method for subjecting solderless connections to thermal stress conditioning by cyclic current loading. This second edition cancels and replaces the first edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- added method B and renamed the former test method as method A, to provide an alternative with more adjustable time "ON" and "OFF" for products with larger thermal mass.
- added introduction to provide background of this revision.
- Standard32 pagesEnglish languagesale 15% off
- Standard21 pagesEnglish and French languagesale 15% off
IEC 60512-28-100:2019 specifies the test methods for signal integrity and transmission performance for connectors specified in respective parts of IEC 60603-7, IEC 61076-1, IEC 61076-2, and IEC 61076-3 standards for connecting hardware applications up to 2 000 MHz. It is also suitable for testing lower frequency connectors, however, the test methodology specified in the detail specification for any given connector remains the reference conformance test for that connector. The above list of connector series of standards does not preclude referencing this document in other connector manufacturer’s specifications or published standards. Test procedures provided herein are:
- insertion loss, test 28a;
- return loss, test 28b;
- near-end crosstalk (NEXT) test 28c;
- far-end crosstalk (FEXT), test 28d;
- transverse conversion loss (TCL), test 28f;
- transverse conversion transfer loss (TCTL), test 28g.
Other test procedures referenced herein are:
- transfer impedance (ZT), see IEC 60512-26-100, test 26e.
- for coupling attenuation (aC), see IEC 62153 4 12.
This second edition cancels and replaces the first edition, issued in 2013, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- The title is revised from 1 000 MHz to 2 000 MHz to reflect the range of frequencies which may be tested.
- All tables and requirements have been revised up to 2 000 MHz.
Key words: Connectors, Signal Integrity Tests
- Standard139 pagesEnglish languagesale 15% off
- Standard90 pagesEnglish and French languagesale 15% off
IEC 60512-11-1:2019 est utilisée, lorsque la spécification particulière (de produit) l'exige, pour soumettre à l'essai des connecteurs qui entrent dans le domaine d'application du comité d'études 48 de l'IEC. Cet essai peut aussi être utilisé sur des dispositifs similaires (c'est-à-dire lorsque les mécanismes de dégradation sont les mêmes) lorsqu'une spécification particulière (de produit) l'indique. L'objet de cet essai est de définir une méthode d'essai normalisée pour évaluer l'aptitude des connecteurs à fonctionner de manière spécifiée dans un environnement spécifié qui pourrait être rencontré dans des conditions normales d'utilisation, y compris le stockage. Le présent document fournit une méthode d'essai composite normalisée pour déterminer l'aptitude des connecteurs soumis à des conditions d'environnement consistant en une séquence de contraintes climatiques comportant température, humidité, et si cela est exigé, basse pression. Mots clés: connecteurs, Essais climatiques
- Standard21 pagesEnglish and French languagesale 15% off
IEC 60512-99-002:2019 is used for testing connectors within the scope of SC 48B that are used in twisted pair communication cabling with remote power, such as ISO/IEC 11801 Class D (or better), balanced cabling in support of IEEE Std 802.3bt™, (PoE Plus – Power over Ethernet Plus).
The object of this document is to detail a test schedule to determine the ability of pairs of connectors to withstand a sequence of tests with a total of 100 engagements and separations. The electrical current is passed through the connectors during the separation (unmating) step only, in accordance with IEC 60512-9-3.
Keywords: Connectors, Engaging and Separating connectors
- Standard24 pagesEnglish and French languagesale 15% off
IEC 60512-23-3:2018. defines a standard test method for measuring the shielding effectiveness SE of a shielded connector, or of a connector not provided with integral shield once fitted with a shielding accessory and terminated with a screened cable. The complete assembly has a continuous 360° shielding capability throughout its length. This test method can be applied to shielded connectors and to connector accessories with shielding capability. The following different connector designs can be tested:
- circular connectors;
- rectangular connectors;
- connectors for printed boards;
- connector shielding accessories.
This test method utilizes the principle that the intrinsic shielding property of the connector/ accessory/cable assembly is its surface transfer impedance ZT which can be expressed as the longitudinal voltage inside the shield, relative to the current flow on the outside shell. This test is also suitable for measuring the shielding effectiveness of a connector fitted with triaxial contacts terminated with shielded, twisted pair cables, as used in data bus systems. This second edition cancels and replaces the first edition, published in 2000. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) an introduction has been added to provide some guidance to this document in view of concurrent test method 23g in the same family;
b) the frequency range for which this test method is considered reliable moved from 1 GHz to 3 GHz, to be consistent with Figure 7 (unchanged) and current industry practice and need;
c) update to IEC 62153-4-6:2017 of former normative reference IEC 60096-4-1:1990, withdrawn and incorrect (should have been IEC 61196-1:1995, also withdrawn);
d) update to current subclause numbers of IEC 62153-4-6:2017 what were the previous subclause numbers referenced in IEC 61196-1:1995 (wrongly attributed to IEC 60096-4-1:1990). For immediate understanding the title of these subclauses has been added;
e) alignment of title to the current scope of SC 48B (connectors) and inclusion of electrical equipment as target application of said connectors (per current scope of TC 48) and explicit reference to the method – line injection – for the measurement of transfer impedance;
f) symbols SE for shielding effectiveness and ZT for surface transfer impedance added throughout the document;
g) list of connectors to which the test method is applicable – previously in 3.1 – moved in scope;
h) former name of AECMA organization changed to the current ASD-STAN;
i) “specimen” used instead of “sample” throughout the document;
j) clarification in the title of what transfer impedance is described in Table 3 and editorial improvement of the same;
k) “dielectric constant” changed into the updated term “relative permittivity”;
l) added a note to warn about the fact that this test method requires in 6.6 a TDR with more stringent rise time of less than 100 ps than the value of less than 350 ps specified both in IEC 62153-4-6 and in EN 50289-1-6 for the similar line injection method applied to screened cables, whereas test 23g of IEC 60512-23-7 specifies for the same purpose a TDR with a rise time of less than 200 ps;
m) adoption of term “connector housing” [IEV 581-27-10] instead of “shell” to address the connector accessory providing the shielding;
n) title “Transfer impedance ZT [Ω]” added to the ordinate axis on the left side of double log diagram of Figure 7;
o) explanatory note to clarify the conversion formula for SE from ZT added.
Key words: Connectors, Screening and Filtering Tests, Shielding Effectiveness
- Standard46 pagesEnglish languagesale 15% off
- Standard30 pagesEnglish and French languagesale 15% off
IEC 60512-1:2018 is intended to be used as a basis for tests and measurements specifications for electrical connectors. It provides guidance and reference for tests and measurements within the IEC 60512 series. It includes the description and the practice of the various phases of tests and measurements (preparation, tests and measurements, requirements, documentation), in addition to basic terms and definitions applicable to any part of the IEC 60512 series. This standard shall be used in conjunction with IEC 60512-1-101 and relevant part(s) of series IEC 60512. Part 60512-1-100 provides the list of the existing test and measuring methods published within series IEC 60512. Detail tests and measurements specifications are applicable to electrical connectors and their components (e.g. connector inserts, connector housings, locking mechanisms, contacts and terminations) within the scope of technical committee 48. They may also be used for similar devices when specified in a detail product specification. Detail tests and measurements specifications are used in conjunction with detail product specifications which prescribe the tests to be used, the required degree of severity for each of them and the permissible performance limits. The detail product specification also specifies the deviations in procedures, which may be required when applying a test to the type of connector or its component under consideration, and it further specifies any special procedures which may be required. This fifth edition cancels and replaces the fourth edition, published in 2001. It constitutes a technical revision. This edition includes the following main technical changes with respect to the previous edition:
– in Clause 3, only terms relating to the testing are defined, and IEC 61076-1 is referred to for terms of connectors.
– Clause 4 (Numbering of tests and measurement specification) is added.
– Subclause 5.1.2 (Calibration) is added.
– in Clause 6 (Test), test procedure follows IEC 60068-1.
Key words: Connectors, Test Specification
- Standard44 pagesEnglish languagesale 15% off
- Standard28 pagesEnglish and French languagesale 15% off
IEC 60512-8-3:2018 Lorsque la spécification particulière (de produit) l’exige, la présente partie de l'IEC 60512 est utilisée pour les essais des connecteurs qui entrent dans le domaine d’application du comité d’études 48 de l'IEC. Elle peut aussi être utilisée pour des dispositifs similaires, lorsqu’une spécification particulière (de produit) le spécifie. L’objet de ce document est de détailler une méthode d’essai normalisée pour évaluer la robustesse de l’ergot d’activation d’un mécanisme d’accouplement ou de relâchement de la connexion. Cette deuxième édition annule et remplace la première édition parue en 2011. La présente édition constitue une révision technique. Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente: La présente édition reflète l'IEC 60512-1-101, Spécification particulière cadre et le paragraphe 4.2 (Préparation du spécimen) est amélioré. Mots clés: connecteurs, Essais de charge statique (embases)
- Standard17 pagesEnglish and French languagesale 15% off
IEC 60512-15-2:2018 La présente partie de l'IEC 60512 est utilisée, lorsque la spécification particulière (de produit) l’exige, pour les essais des connecteurs qui entrent dans le domaine d’application du comité d’études 48. Elle peut aussi être utilisée pour des dispositifs similaires lorsqu’une spécification particulière (de produit) le spécifie. L’objet de ce document est de détailler une méthode d’essai normalisée pour évaluer l’efficacité du système de retenue d’un isolant de connecteur à l'intérieur d'un boîtier de connecteur à résister aux forces axiales susceptibles d'être rencontrées au cours d’une utilisation normale, c'est-à-dire les forces d'insertion et d'extraction les plus élevées dans/en provenance d'un connecteur d'accouplement correspondant, l'isolant de connecteur n'étant pas détaché du boîtier de connecteur. La méthode d’essai détaillée dans le présent document accompagne celle détaillée dans l'IEC 60512-15-3. Cette deuxième édition annule et remplace la première édition, parue en 2008, dont elle constitue une révision technique. Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente: La méthode d'essai B (méthode de la pression) appropriée aux essais du connecteur hermétique a été ajoutée. La présente édition reflète l'IEC 60512-1-101, Spécification particulière cadre. Mots clés: connecteurs, essais des connecteurs, Rétention de l'isolant
- Standard16 pagesEnglish and French languagesale 15% off
IEC 60512-1-101:2015 This blank detail (tests and measurements) specification is a supplementary document to the IEC 60512 test and measurements specification series and contains requirements for style, layout and content of test and measurements specifications for connectors. The content of this blank detail (tests and measurements) specification is laid out in two parts: one page contains the example of the blank detail tests and measurements specification, on the adjacent page, the guidance notes refer to the example. The guidance notes have the same numbering as the relevant clauses of the example pages. The example pages may be used as a template when preparing a detail (tests and measurements) specification within the scope of this standard. Key words: Connectors, Guidance, Detail Specification
- Standard21 pagesEnglish and French languagesale 15% off
L'IEC 60512-29-100:2015 spécifie les méthodes d'essais pour les performances des transmissions pour les connecteurs de type M12 jusqu'à 500 MHz. Elle est également applicable aux essais réalisés sur des connecteurs à fréquences plus basses s'ils satisfont aux exigences des spécifications particulières et de la présente norme. Les méthodes d'essai spécifiées ici sont: - perte d'insertion, essai 29a; - affaiblissement de réflexion, essai 29b; - paradiaphonie (NEXT), essai 29c; - télédiaphonie (FEXT), essai 29d; - perte de conversion transverse (TCL), essai 29f; - perte de transfert de conversion transverse (TCTL), essai 29g. Pour l'essai d'impédance de transfert (ZT), voir l'IEC 60512-26-100, essai 26e. Pour l'affaiblissement de couplage, voir l'ISO/IEC 11801. Toutes les figures représentent des principes pour des câblages de quatre paires Mots-clés: Connecteurs, Intégrité des signaux, Connecteurs de type M12
- Standard106 pagesEnglish and French languagesale 15% off
IEC 60512-99-001:2012 used for the assessment of connectors within the scope of SC 48B that are used in twisted pair communication cabling with remote power, such as ISO/IEC 11801 Class D, or better, balanced cabling in support of IEEE Std 802.3at - 2009 (latest edition (PoE Plus - Power over Ethernet Plus). The object of this standard is to detail a test schedule to determine the ability of connectors to withstand a minimal number of engagements and separations when an electrical current is being passed through the connector in accordance with IEC 60512-9-3. Keywords: connectors, engaging and separating connectors
- Standard22 pagesEnglish and French languagesale 15% off
IEC 60512-16-21:2012 The object of this standard is to define a standard test method to assess the possibility of whisker growth by external mechanical stress on the tin and tin-alloy plated parts of a connector in its application (after wire termination, after soldering, after mounting, mated with counterpart). This standard does not cover internal stress type whisker. This part of IEC 60512, when required by the detail specification, is used for testing connectors within the scope of IEC technical committee 48. It may also be used for similar devices when specified in a detail specification. Keywords: Whisker growth, external mechanical stress
- Standard21 pagesEnglish and French languagesale 15% off
IEC 60512-1-100:2012 provides a listing of the 60512 series of standards for specific tests that are created for connectors. Further it gives cross-references with the former (60)512 standards, where different test numbers were used. The connector tests as such are mainly identical with the previously published standards; minor changes may be introduced due to technical developments (e.g. other soldering temperatures in soldering tests, resulting from the introduction of lead-free soldering). The former issues were in booklets, with several related tests in one document, while the present issues are leaflets, each featuring one single test. This third edition cancels and replaces the second edition published in 2006. This edition constitutes a technical revision. This new edition reflects the status of publications in the IEC 60512 series as of September 1st 2011.
- Standard20 pagesEnglish and French languagesale 15% off
IEC 60512-27-100:2011 specifies the test methods for transmission performance for IEC 60603-7 series connectors up to 500 MHz. It is also suitable for testing lower frequency connectors if they meet the requirements of the detail specifications and of this standard. The test methods provided are: - insertion loss, - return loss, - near-end crosstalk (NEXT), - far-end crosstalk (FEXT), - transverse conversion loss (TCL) and - transverse conversion transfer loss (TCTL). For the transfer impedance (Zt) test, see IEC 60512-26-100 and for the coupling attenuation, see IEC 62153-4-12.
- Standard140 pagesEnglish and French languagesale 15% off
IEC 60512-9-2:2011 when required by the detail specification, this part of IEC 60512, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard test method to assess the ability of a connector to withstand elevated temperatures with electrical loading. This standard cancels and replaces Test 9b of IEC 60512-5, issued in 1992.
- Standard13 pagesEnglish and French languagesale 15% off
IEC 60512-7-2:2011 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard test method to assess the ability of a free connector on the end of a cable or wire bundle to withstand impacts it could receive when dropped onto a hard surface.
- Standard16 pagesEnglish and French languagesale 15% off
La CEI 60512-9-3:2011 précise une méthode d'essai normalisée pour évaluer l'endurance fonctionnelle mécanique et électrique, c'est-à-dire les cycles d'accouplement et de désaccouplement, des connecteurs en mode de fonctionnement normal sous une charge électrique spécifiée. Cette deuxième édition annule et remplace l'Essai 9c de la CEI 60512-5, parue en 1992, et constitue une révision technique. Les modifications principles par rapport à l'édition précédente sont les suivantes: - Ajout d'une exigence au 4.1 qui précise que lorsqu'il y a plus d'un circuit électrique câblée pour les essais, le câblage doit être fait dans un circuit électrique parallèle. - Les paragraphes 4.3. à 4.7 ont été supprimés et remplacés par les paragraphes 4.2 à 4.4. Cette publication doit être lue conjointement avec la CEI 60512-1:2001 et la CEI 60512-1-100:2006.
- Standard17 pagesEnglish and French languagesale 15% off
La CEI 60512-17-2:2011 lorsque la spécification particulière l'exige, est utilisée pour les essais des connecteurs qui entrent dans le domaine d'application du Comité d'Etudes 48 de la CEI. Ces essais peuvent aussi être utilisés sur des composants similaires lorsqu'une spécification particulière le précise. L'objet du présent norme est de définir une méthode normalisée pour évaluer l'aptitude d'un dispositif de pincement de câble à permettre un mouvement de rotation du faisceau de câbles/fils sans endommager la surface externe du faisceau de câbles/fils, le dispositif de pincement, le connecteur ou le sous-ensemble. La présente norme annule et remplace l'Essai 17b de la CEI 60512-9, publiée en 1992. Elle constitue une révision technique. Cette publication doit être lue conjointement avec la CEI 60512-1:2001 et la CEI 60512-1-100:2006.
- Standard12 pagesEnglish and French languagesale 15% off
La CEI 60512-9-4:2011 lorsque la spécification particulière l'exige, est utilisée pour les essais des connecteurs qui entrent dans le domaine d'application du comité d'etudes 48 de la CEI. Ces essais peuvent aussi être utilisés sur des composants similaires lorsqu'une spécification particulière le prescrit. L'objet du présent norme est de définir une méthode d'essai normalisée pour évaluer l'aptitude d'un connecteur à résister à des contraintes causées par l'extraction et l'insertion répétées des contacts au cours des opérations d'entretien. La présente norme annule et remplace l'Essai 9d de la CEI 60512-5, publiée en 1992 et constitue une révision technique.
Cette publication doit être lue conjointement avec la CEI 60512-1:2001 et la CEI 60512-1-100:2006.
- Standard12 pagesEnglish and French languagesale 15% off
La CEI 60512-8-2:2011 lorsque la spécification particulière l'exige, est utilisée pour les essais des connecteurs qui entrent dans le domaine d'application du comité d'études 48 de la CEI. Ces essais peuvent aussi être utilisés sur des composants similaires lorsqu'une spécification particulière le prescrit. L'objet du présent norme est de définir une méthode d'essai normalisée pour évaluer l'aptitude d'une embase à supporter une force axiale constante qui pourrait se produire pendant l'usage normal. La présente norme annule et remplace l'Essai 8b de la CEI 60512-5, publiée en 1992. Elle constitue une révision technique. Cette publication doit être lue conjointement avec la CEI 60512-1:2001 et la CEI 60512-1-100:2006.
- Standard13 pagesEnglish and French languagesale 15% off
IEC 60512-8-3:2011 when required by the detail specification, is used for testing connectors within the scope of IEC technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard test method to assess the robustness of the actuating lever of a connector mating or release mechanism. This standard cancels and replaces Test 8c of IEC 60512-5, issued in 1992, and constitutes a technical revision.
This publication is to be read in conjunction with IEC 60512-1:2001 and IEC 60512-1-100:2006.
- Standard16 pagesEnglish and French languagesale 15% off
- Standard8 pagesEnglish and French languagesale 15% off
IEC 60512-17-3:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard test method to assess the ability of a cable-clamping device to prevent longitudinal movement of the cable/wire bundle.
- Standard9 pagesEnglish and French languagesale 15% off
IEC 60512-17-4:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard test method to assess the ability of a cable-clamping device to prevent the rotation of the cable/wire bundle around its axis.
- Standard9 pagesEnglish and French languagesale 15% off
IEC 60512-20-3:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard test method to determine the flammability of a connector when exposed to a glow-wire test under specified conditions. The glow-wire test simulates thermal stresses which may be produced by such sources of heat or ignition as, for example, glowing elements or overloaded components, for short periods, in order to assess by a simulation technique the fire hazard or burning of a single electronic component.
- Standard12 pagesEnglish and French languagesale 15% off
IEC 60512-23-2:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard method to measure suppression characteristics (insertion loss) introduced by single and multiple circuit radio-frequency filters which are an integral part of a connector.
- Standard9 pagesEnglish and French languagesale 15% off
IEC 60512-22-1:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard test method to determine the capacitance between conductive elements of connectors.
- Standard9 pagesEnglish and French languagesale 15% off
IEC 60512-20-1:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard method to determine the flammability of a connector when exposed to a needle-flame under specified conditions. The needle-flame test is intended to simulate the effect of small flames which may result from fault conditions within the equipment, i.e. the intensity of the ignition source used is of a similar order to that of an accidentally overheated or burning single electronic component.
- Standard12 pagesEnglish and French languagesale 15% off
IEC 60512-21-1:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard test method to determine the value of RF shunt resistance which degrades the quality factor of an L/C circuit when a connector is connected in parallel. This value is expressed in terms of a parallel damping resistance.
- Standard8 pagesEnglish and French languagesale 15% off
IEC 60512-17-1:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard test method to assess the ability of a cable-clamping device to withstand mechanical stresses likely to be encountered during normal usage.
- Standard9 pagesEnglish and French languagesale 15% off
IEC 60512-8-1:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard test method to assess the suitability of a fixed connector for use in applications where it may be subject to transverse stresses.
- Standard9 pagesEnglish and French languagesale 15% off
IEC 60512-24-1:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard method to measure the residual magnetism of a connector after exposure to a specified magnetic field.
- Standard8 pagesEnglish and French languagesale 15% off
IEC 60512-19-1:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard method to assess the ability of the insulation of pre-insulated crimp barrels to withstand specified fluids under specified conditions.
- Standard9 pagesEnglish and French languagesale 15% off
IEC 60512-9-5:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard method for subjecting solderless connections to thermal stress conditioning by cyclic current loading.
- Standard9 pagesEnglish and French languagesale 15% off
IEC 60512-7-1:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to define a standard test method to assess the ability of a connector to withstand the impacts it would receive when dropped repeatedly.
- Standard13 pagesEnglish and French languagesale 15% off
IEC 60512-9-1:2010 when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard test method to assess the mechanical operational endurance of connectors in the normal operating mode, without electrical load.
- Standard9 pagesEnglish and French languagesale 15% off
IEC 60512-25-9:2008 defines a test method which is intended to assess the near-end alien crosstalk and the far-end alien crosstalk between connectors in close proximity, when mounted in their mounting systems. Both discrete modular connectors and multi-port panel connectors may be tested using this method. This method provides a means to test the alien crosstalk between any two ports, as well as a means to assess the overall alien crosstalk from all other ports. Is generally applicable to any electrical connector, and is particularly suitable to connectors described in IEC 60603-7 series, IEC 61076-3-104, and other types of connectors for data transmission.
- Standard37 pagesEnglish and French languagesale 15% off
IEC 60512-16-17:2008 details a standard test method to determine the ability of a fixed male tab and its fixing to withstand specified tensile and compressive forces. If so specified in the detail specification, forces other than tension and compression may be applied.
- Standard13 pagesEnglish and French languagesale 15% off
IEC 60512-16-5:2008 details a standard test method to determine the holding capacity of contacts with resilient features by means of gauges.
- Standard9 pagesEnglish and French languagesale 15% off
IEC 60512-16-16:2008 details a standard test method to determine the ability of a fixed male tab and its fixing to withstand a specified torque. If so specified in the detail specification, forces other than torsional may be applied.
- Standard12 pagesEnglish and French languagesale 15% off
IEC 60512-16-6:2008 details a standard test method to assess the ability of terminations to withstand the mechanical stresses likely to be applied during normal assembly operations.
- Standard9 pagesEnglish and French languagesale 15% off
IEC 60512-16-7:2008 details a standard test method to assess the effectiveness of contacts to resist deformation (damage) from crimping operations.
- Standard13 pagesEnglish and French languagesale 15% off
IEC 60512-16-3:2008 details a standard test method to determine the ability of a contact to withstand a specified bending moment or force. If so specified in the detail specification, forces other than bending may be applied.
- Standard13 pagesEnglish and French languagesale 15% off
IEC 60512-16-14:2008 details a standard test method to determine the ability of a fixed male tab and its fixing to withstand a specified bending stress. If so specified in the detail specification, forces other than bending may be applied.
- Standard12 pagesEnglish and French languagesale 15% off
IEC 60512-16-1:2008 details a standard test method to assess the effectiveness of the elastic system of contacts to resist damage from the insertion of a specified test probe.
- Standard12 pagesEnglish and French languagesale 15% off
Frequently Asked Questions
WG 5 is a Technical Committee within the International Electrotechnical Commission (IEC). It is named "Test methods" and is responsible for: To standardize test procedures for electrical connectors and electrical devices. To prepare 60512-23-7, 60512-25-5, 60512-25-7, 60512-25-9 and 60512-26-100 standards This committee has published 577 standards.
WG 5 develops IEC standards in the area of Information technology. The scope of work includes: To standardize test procedures for electrical connectors and electrical devices. To prepare 60512-23-7, 60512-25-5, 60512-25-7, 60512-25-9 and 60512-26-100 standards Currently, there are 577 published standards from this technical committee.
The International Electrotechnical Commission (IEC) is the world's leading organization for the preparation and publication of international standards for electrical, electronic, and related technologies. Founded in 1906, the IEC provides a global platform for companies, industries, and governments to meet, discuss, and develop the international standards they require.
A Technical Committee (TC) in IEC is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.