Connectors for electronic equipment - Tests and measurements - Part 8-3: Static load tests (fixed connectors) - Test 8c: Robustness of actuating lever

IEC 60512-8-3:2011 when required by the detail specification, is used for testing connectors within the scope of IEC technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard test method to assess the robustness of the actuating lever of a connector mating or release mechanism. This standard cancels and replaces Test 8c of IEC 60512-5, issued in 1992, and constitutes a technical revision.
This publication is to be read in conjunction with  IEC 60512-1:2001 and IEC 60512-1-100:2006.

Connecteurs pour équipements électroniques - Essais et mesures - Partie 8-3: Essais de charge statique (embases) - Essai 8c: Robustesse de l'ergot d'activation

La CEI 60512-8-2:2011 lorsque la spécification particulière l'exige, est utilisée pour les essais des connecteurs qui entrent dans le domaine d'application du Comité d'Etudes 48 de la CEI. Ces essais peuvent aussi être utilisés sur des composants similaires lorsqu'une spécification particulière le prescrit. L'objet du présent norme est définir une méthode d'essai normalisée pour évaluer la robustesse de l'ergot d'activation d'un mécanisme d'accouplement et de relâchement de la connexion. La présente norme annule et remplace l'Essai 8c de la CEI 60512-5, publiée en 1992. Elle constitue une révision technique.
Cette publication doit être lue conjointement avec la  CEI 60512-1:2001 et la CEI 60512-1-100:2006.

General Information

Status
Published
Publication Date
06-Apr-2011
Technical Committee
SC 48B - Electrical connectors
Current Stage
DELPUB - Deleted Publication
Start Date
12-Jan-2018
Completion Date
26-Oct-2025

Relations

Effective Date
05-Sep-2023

Overview

IEC 60512-8-3:2011 is an international standard published by the International Electrotechnical Commission (IEC) that specifies the test methods for assessing the robustness of the actuating lever on fixed connectors used in electronic equipment. This part of the IEC 60512 series focuses specifically on static load tests (Test 8c) designed to evaluate the mechanical durability and operational reliability of connector actuating levers, which are critical components for mating and release mechanisms.

The standard applies mainly to connectors within the scope of IEC Technical Committee 48, which covers electromechanical components for electronic equipment. It is also applicable to similar devices when required by detailed product specifications. This edition, released in 2011, replaces the earlier 1992 version from IEC 60512-5 and introduces updated procedures and measurement requirements.

Key Topics

  • Scope and Objective
    Defines the purpose of the test to ensure the actuating lever withstands static forces and torques without damage that would impair normal function.

  • Test Preparation
    Includes mounting the connector specimen on a panel or chassis cut-out, using suitable test equipment such as a universal materials testing machine, and ensuring proper fixture alignment.

  • Force Application
    The standard outlines specific directions and methods for applying forces to the lever:

    • Forces perpendicular to the lever axis in the plane of lever travel at each lever end position.
    • Forces perpendicular to the lever axis but perpendicular to the plane of lever travel.
    • Forces axial to the lever axis, both toward and away from the lever pivot.

    The force is increased steadily (approximately 20 N/s) to a specified value and held for 1 minute.

  • Torque Application
    A specified torque is applied around the lever axis in both directions and maintained for 1 minute to test rotational robustness.

  • Final Inspection and Measurement
    Visual examination is conducted according to IEC 60512-1-1 (Test 1a) to check for damage. Operational characteristics and functionalities are verified post-test to confirm no degradation.

  • Specification Details
    The standard requires detailed specification including mounting parameters, force and torque values, direction and rate of application, test fixtures, and any deviations from the normative method.

Applications

IEC 60512-8-3 is highly relevant for manufacturers, designers, and quality assurance professionals working with electronic connectors, particularly:

  • Connector Manufacturers developing reliable mating and release mechanisms with durable actuating levers.
  • Electronic Equipment Producers who require validated connector robustness as part of product reliability and safety certifications.
  • Quality and Compliance Testing Labs performing standardized mechanical testing to meet international regulatory and customer requirements.
  • Product Designers and Engineers ensuring connector components meet operational and mechanical endurance demands under expected static loads.

By adhering to IEC 60512-8-3, stakeholders can guarantee that actuating levers withstand mechanical stresses encountered in normal use, thereby reducing failure risks and ensuring product longevity.

Related Standards

  • IEC 60512-1:2001 – General testing procedures for connectors within the IEC 60512 series.
  • IEC 60512-1-100:2006 – Applicable publications and explanations on the structure of IEC 60512 tests.
  • IEC 60512-14 series – Sealing tests for connectors, which may complement mechanical robustness testing depending on product requirements.
  • IEC 60529 – Degrees of protection (IP Code) for enclosures, relevant for end products requiring environmental resistance alongside mechanical robustness.

Conclusion

IEC 60512-8-3:2011 provides a comprehensive, standardized approach to verify the mechanical robustness of actuating levers on fixed connectors. This ensures reliable performance in electronic equipment under static load conditions, helping manufacturers and users meet the highest quality and safety standards. Utilizing this international standard supports product durability, operational safety, and compliance within global markets.

Keywords: IEC 60512-8-3, actuating lever robustness, fixed connectors, static load tests, connector testing standard, electronic equipment connectors, IEC connector tests, mechanical durability, connector actuating mechanism

Standard

IEC 60512-8-3:2011 - Connectors for electronic equipment - Tests and measurements - Part 8-3: Static load tests (fixed connectors) - Test 8c: Robustness of actuating lever Released:4/7/2011

English and French language
16 pages
sale 15% off
Preview
sale 15% off
Preview

Frequently Asked Questions

IEC 60512-8-3:2011 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Connectors for electronic equipment - Tests and measurements - Part 8-3: Static load tests (fixed connectors) - Test 8c: Robustness of actuating lever". This standard covers: IEC 60512-8-3:2011 when required by the detail specification, is used for testing connectors within the scope of IEC technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard test method to assess the robustness of the actuating lever of a connector mating or release mechanism. This standard cancels and replaces Test 8c of IEC 60512-5, issued in 1992, and constitutes a technical revision. This publication is to be read in conjunction with IEC 60512-1:2001 and IEC 60512-1-100:2006.

IEC 60512-8-3:2011 when required by the detail specification, is used for testing connectors within the scope of IEC technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a standard test method to assess the robustness of the actuating lever of a connector mating or release mechanism. This standard cancels and replaces Test 8c of IEC 60512-5, issued in 1992, and constitutes a technical revision. This publication is to be read in conjunction with IEC 60512-1:2001 and IEC 60512-1-100:2006.

IEC 60512-8-3:2011 is classified under the following ICS (International Classification for Standards) categories: 17.140.50 - Electroacoustics; 31.220.01 - Electromechanical components in general. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 60512-8-3:2011 has the following relationships with other standards: It is inter standard links to IEC 60512-8-3:2018. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

IEC 60512-8-3:2011 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


IEC 60512-8-3 ®
Edition 1.0 2011-04
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Connectors for electronic equipment – Tests and measurements –
Part 8-3: Static load tests (fixed connectors) – Test 8c: Robustness of actuating
lever
Connecteurs pour équipements électroniques – Essais et mesures –
Partie 8-3: Essais de charge statique (embases) – Essai 8c: Robustesse de
l’ergot d’activation
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by

any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or

IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,

please contact the address below or your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie

et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.

Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette

publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.

IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
 Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
 IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
 Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
 Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
 Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm
Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de référence,
texte, comité d’études,…). Il donne aussi des informations sur les projets et les publications retirées ou remplacées.
 Just Published CEI: www.iec.ch/online_news/justpub
Restez informé sur les nouvelles publications de la CEI. Just Published détaille deux fois par mois les nouvelles
publications parues. Disponible en-ligne et aussi par email.
 Electropedia: www.electropedia.org
Le premier dictionnaire en ligne au monde de termes électroniques et électriques. Il contient plus de 20 000 termes et
définitions en anglais et en français, ainsi que les termes équivalents dans les langues additionnelles. Egalement appelé
Vocabulaire Electrotechnique International en ligne.
 Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm
Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du
Service clients ou contactez-nous:
Email: csc@iec.ch
Tél.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 60512-8-3 ®
Edition 1.0 2011-04
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Connectors for electronic equipment – Tests and measurements –
Part 8-3: Static load tests (fixed connectors) – Test 8c: Robustness of actuating
lever
Connecteurs pour équipements électroniques – Essais et mesures –
Partie 8-3: Essais de charge statique (embases) – Essai 8c: Robustesse de
l’ergot d’activation
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX H
ICS 31.220.01 ISBN 978-2-88912-447-3

– 2 – 60512-8-3  IEC:2011
CONTENTS
FOREWORD . 3

1 Scope and object . 5

2 Normative references . 5

3 Preparation . 5

3.1 Preparation of the specimen . 5

3.2 Equipment . 5

3.3 Mounting . 5

4 Test method . 6
4.1 Force . 6
4.2 Torque . 7
5 Final measurements . 7
6 Requirements . 7
7 Details to be specified . 7
Bibliography . 8

Figure 1 – Details of force application . 6

60512-8-3  IEC:2011 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION

____________
CONNECTORS FOR ELECTRONIC EQUIPMENT –

TESTS AND MEASUREMENTS –
Part 8-3: Static load tests (fixed connectors) –

Test 8c: Robustness of actuating lever

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of

patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60512-8-3 has been prepared by subcommittee 48B: Connectors,
of IEC technical committee 48: Electromechanical components and mechanical structures for
electronic equipment.
This standard cancels and replaces Test 8c of IEC 60512-5, issued in 1992, and constitutes a
technical revision.
This standard is to be read in conjunction with IEC 60512-1 and IEC 60512-1-100, which
explains the structure of the IEC 60512 series.

– 4 – 60512-8-3  IEC:2011
The text of this standard is based on the following documents:

CDV Report on voting
48B/2121/CDV 48B2214/RVC
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.

This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

A list of all parts in the IEC 60512 series, under the general title Connectors for electronic
equipment – Tests and measurements, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
60512-8-3  IEC:2011 – 5 –
CONNECTORS FOR ELECTRONIC EQUIPMENT –

TESTS AND MEASUREMENTS –
Part 8-3: Static load tests (fixed connectors) –

Test 8c: Robustness of actuating lever

1 Scope and object
This part of IEC 60512, when required by the detail specification, is used for testing
connectors within the scope of IEC technical committee 48. It may also be used for similar
devices when specified in a detail specification.
The object of this standard is to detail a standard test method to assess the robustness of the
actuating lever of a connector mating or release mechanism.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 60512-1, Connectors for electronic equipment – Tests and measurements – Part 1:
General
IEC 60512-1-1, Connectors for electronic equipment – Tests and measurements – Part 1-1:
General examination – Test 1a: Visual examination
IEC 60512-1-100, Connectors for electronic equipment – Tests and measurements –
Part 1-100: General – Applicable publications
3 Preparation
3.1 Preparation of the specimen
The specimen shall not be wired but shall be fitted with such accessories as may be required
by the detail specification.
Unless otherwise specified, the specimen shall be mounted in the normal manner, using the
normal panel or chassis cut-out as laid down in the detail specification.
NOTE The plate should be strong enough to sustain the applied forces. The length and width of the plate should
be such that the contour of the specimen is exceeded.
3.2 Equipment
A suitable test tool (e.g. a universal materials testing machine) and appropriate adapters shall
be used.
3.3 Mounting
Unless otherwise specified, the specimen shall be mounted in the normal manner, using the
normal panel or chassis cut-out as laid down in the detail specification.

– 6 – 60512-8-3  IEC:2011
NOTE The plate should be strong enough to sustain the applied forces. The length and width of the plate should

be such that the contour of the specimen is e
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...