Abstract

IEC 60512-25-9:2008 defines a test method which is intended to assess the near-end alien crosstalk and the far-end alien crosstalk between connectors in close proximity, when mounted in their mounting systems. Both discrete modular connectors and multi-port panel connectors may be tested using this method. This method provides a means to test the alien crosstalk between any two ports, as well as a means to assess the overall alien crosstalk from all other ports. Is generally applicable to any electrical connector, and is particularly suitable to connectors described in IEC 60603-7 series, IEC 61076-3-104, and other types of connectors for data transmission.

Status
Published
Publication Date
27-Aug-2008
Technical Committee
SC 48B - Electrical connectors
Drafting Committee
WG 5 - Test methods
Current Stage
PPUB - Publication issued - 60 Publication
Start Date
28-Aug-2008
Due Date
30-Sep-2008
Completion Date
30-Sep-2008

Buy Documents

Standard

IEC 60512-25-9:2008 - Connectors for electronic equipment - Tests and measurements - Part 25-9: Signal integrity tests - Test 25i: Alien crosstalk

ISBN:2-8318-9971-0
English and French language (37 pages)
sale 15% off
Preview
sale 15% off
Preview

Overview

IEC 60512-25-9:2008, titled "Connectors for electronic equipment - Tests and measurements - Part 25-9: Signal integrity tests - Test 25i: Alien crosstalk," is an international standard developed by the International Electrotechnical Commission (IEC). This standard specifies a test method designed to assess the near-end alien crosstalk (ANEXT) and far-end alien crosstalk (AFEXT) between electronic connectors positioned in close proximity within their mounting systems. It is applicable to discrete modular connectors and multi-port panel connectors commonly used in data transmission applications.

The standard provides a structured methodology to evaluate alien (exogenous) crosstalk, which is the signal interference caused by adjacent connectors and ports. By measuring this unwanted coupling, it helps ensure signal integrity and reliable data transmission in complex electronic equipment assemblies.


Key Topics

Alien Crosstalk Types

  • Near-end alien crosstalk (ANEXT): Signal interference measured at the near-end from disturbing conductor pairs in neighboring connectors.
  • Far-end alien crosstalk (AFEXT): Signal interference measured at the far-end, impacting the connector under test.
  • Power sum calculations: Combined effect of multiple interfering signals producing aggregate alien crosstalk losses at both near-end and far-end.

Test Methodology

  • Test setup: Involves mounting connectors in their intended mounting systems such as faceplates, panels, or frames with multiple connectors.
  • Measurement system: Use of calibrated measurement devices and terminations with appropriate cabling (minimum two cables each 40m long) to accurately quantify crosstalk.
  • Pair combinations: Consideration of all pairs within connectors (typically four conductor pairs per connector equating to 16 combinations for each port).
  • Use of automatic switching: Recommended for efficient testing across multiple pairs and ports.
  • Isolation and termination: Ensuring cables are separated appropriately to minimize external interference during tests.

Scope and Applications

  • Suitable for any electrical connector but particularly aligned with connectors outlined in IEC 60603-7 series, IEC 61076-3-104, and similar data transmission connectors.
  • Enables manufacturers to define worst-case mounting scenarios and test the connectors’ susceptibility to alien crosstalk in realistic configurations.
  • Provides guidance to confirm whether additional disturbing connectors influence the crosstalk performance, ensuring comprehensive assessment.

Applications

IEC 60512-25-9:2008 is highly valuable across industries and sectors where high-speed data transmission and signal integrity are critical, including:

  • Telecommunications: Ensuring data ports and modular connectors in communication equipment meet stringent crosstalk requirements.
  • Data Centers: Testing multi-port panel connectors and modular cables used in densely packed racks to minimize signal degradation.
  • Industrial Electronics: Verification of connectors in control and automation systems subject to electromagnetic interference.
  • Consumer Electronics: Assessment of connectors in devices requiring reliable high-frequency data transfer.
  • Network Equipment Manufacturers: Validating product designs to conform to industry standards and improve interoperability.

This standard supports quality assurance, product development, and compliance with global interoperability requirements, which are essential for minimizing data errors and enhancing overall system performance.


Related Standards

To facilitate comprehensive connector testing and standardization, IEC 60512-25-9 references and complements several other key international standards:

  • IEC 60603-7 Series: Detailed specifications for 8-way (un)shielded connectors used in data transmissions up to 250 MHz.
  • IEC 61076-3-104: Specifications for shielded connectors for data transmission frequencies up to 1000 MHz.
  • IEC 60050-581: The International Electrotechnical Vocabulary defining terms related to electromechanical components.
  • IEC 60512-26-100: Measurement setup, arrangements, and reference methods for connector testing.
  • IEC 61156: Standards addressing multicore and symmetrical pair/quad cables for digital communications.

These standards collectively ensure a harmonized approach to connector design, testing, and certification, addressing signal integrity from cable through connector to equipment interfaces.


Keywords: IEC 60512-25-9, alien crosstalk test, near-end alien crosstalk, far-end alien crosstalk, signal integrity, electronic connectors, connector testing, IEC connector standards, data transmission connectors, multi-port connectors, electromagnetic interference, crosstalk measurement, IEC 60603-7, IEC 61076-3-104, power sum alien crosstalk.

Buy Documents

Standard

IEC 60512-25-9:2008 - Connectors for electronic equipment - Tests and measurements - Part 25-9: Signal integrity tests - Test 25i: Alien crosstalk

ISBN:2-8318-9971-0
English and French language (37 pages)
sale 15% off
Preview
sale 15% off
Preview

Frequently Asked Questions

IEC 60512-25-9:2008 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Connectors for electronic equipment - Tests and measurements - Part 25-9: Signal integrity tests - Test 25i: Alien crosstalk". This standard covers: IEC 60512-25-9:2008 defines a test method which is intended to assess the near-end alien crosstalk and the far-end alien crosstalk between connectors in close proximity, when mounted in their mounting systems. Both discrete modular connectors and multi-port panel connectors may be tested using this method. This method provides a means to test the alien crosstalk between any two ports, as well as a means to assess the overall alien crosstalk from all other ports. Is generally applicable to any electrical connector, and is particularly suitable to connectors described in IEC 60603-7 series, IEC 61076-3-104, and other types of connectors for data transmission.

IEC 60512-25-9:2008 defines a test method which is intended to assess the near-end alien crosstalk and the far-end alien crosstalk between connectors in close proximity, when mounted in their mounting systems. Both discrete modular connectors and multi-port panel connectors may be tested using this method. This method provides a means to test the alien crosstalk between any two ports, as well as a means to assess the overall alien crosstalk from all other ports. Is generally applicable to any electrical connector, and is particularly suitable to connectors described in IEC 60603-7 series, IEC 61076-3-104, and other types of connectors for data transmission.

IEC 60512-25-9:2008 is classified under the following ICS (International Classification for Standards) categories: 31.220.10 - Plug-and-socket devices. Connectors. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 60512-25-9:2008 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


IEC 60512-25-9
Edition 1.0 2008-08
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Connectors for electronic equipment – Tests and measurements –
Part 25-9: Signal integrity tests – Test 25i: Alien crosstalk

Connecteurs pour équipements électroniques – Essais et mesures –
Partie 25-9: Essais d'intégrité des signaux – Essai 25i: Diaphonie exogène

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by
any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or
IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.

IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
ƒ Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm
Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de référence,
texte, comité d’études,…). Il donne aussi des informations sur les projets et les publications retirées ou remplacées.
ƒ Just Published CEI: www.iec.ch/online_news/justpub
Restez informé sur les nouvelles publications de la CEI. Just Published détaille deux fois par mois les nouvelles
publications parues. Disponible en-ligne et aussi par email.
ƒ Electropedia: www.electropedia.org
Le premier dictionnaire en ligne au monde de termes électroniques et électriques. Il contient plus de 20 000 termes et
définitions en anglais et en français, ainsi que les termes équivalents dans les langues additionnelles. Egalement appelé
Vocabulaire Electrotechnique International en ligne.
ƒ Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm
Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du
Service clients ou contactez-nous:
Email: csc@iec.ch
Tél.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 60512-25-9
Edition 1.0 2008-08
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Connectors for electronic equipment – Tests and measurements –
Part 25-9: Signal integrity tests – Test 25i: Alien crosstalk

Connecteurs pour équipements électroniques – Essais et mesures –
Partie 25-9: Essais d'intégrité des signaux – Essai 25i: Diaphonie exogène

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
R
CODE PRIX
ICS 31.220.10 ISBN 2-8318-9971-0
– 2 – 60512-25-9 © IEC:2008
CONTENTS
FOREWORD.3
1 Scope and object .5
2 Normative references.5
3 Terms and definitions .5
4 Overview .6
4.1 Procedure.6
4.2 Resources .7
5 Overall test arrangement.7
5.1 General .7
5.2 Terminations .8
5.3 Pairs of connectors to test .8
6 Procedure to test alien crosstalk from one connector to another connector .10
6.1 Calibration.10
6.2 Measurement (noise) floor .10
6.3 Alien crosstalk measurement .10
7 Procedure for determining significance.11
8 Details to be specified in the detail specification.12
9 Power sum calculation, report and documentation .12
Annex A (informative) Flow chart for obtaining alien crosstalk performance data.13
Annex B (informative) Illustrations of alien crosstalk testing using coaxial switching.14
Bibliography .18

Figure 1 – Schematic for testing without a switch.8
Figure 2 – Schematic for terminations .8
Figure 3 – Connector array.9
Figure 4 – Test directions.11
Figure A.1 – Flowchart for the test procedure .13
Figure B.1 – Schematic for testing with a switch .14
Figure B.2 – Example network analyzer, switch, and fixture with 8 baluns in 2 clusters.15
Figure B.3 – Example of fixture, in which balun clusters can slide left and right.16
Figure B.4 – Post can rotate three different directions.17

60512-25-9 © IEC:2008 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
CONNECTORS FOR ELECTRONIC EQUIPMENT –
TESTS AND MEASUREMENTS –
Part 25-9: Signal integrity tests –
Test 25i: Alien crosstalk
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60512-25-9 has been prepared by subcommittee 48B: Connectors,
of IEC technical committee 48: Electromechanical components and mechanical structures for
electronic equipment.
The text of this standard is based on the following documents:
FDIS Report on voting
48B/1915/FDIS 48B/1930/RVD
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts of IEC 60512 series, under the general title Connectors for electronic
equipment – Tests and measurements, can be found on the IEC website.

– 4 – 60512-25-9 © IEC:2008
The committee has decided that the contents of this publication will remain unchanged until the
maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
60512-25-9 © IEC:2008 – 5 –
CONNECTORS FOR ELECTRONIC EQUIPMENT –
TESTS AND MEASUREMENTS –
Part 25-9: Signal integrity tests –
Test 25i: Alien crosstalk
1 Scope and object
This part of IEC 60512 defines a test method which is intended to assess the near-end alien
crosstalk (ANEXT) and the far-end alien crosstalk (AFEXT) between connectors in close
proximity, when mounted in their mounting systems. Both discrete modular connectors and
multi-port panel connectors may be tested using this method. This method provides a means to
test the alien (exogenous) crosstalk between any two ports, as well as a means to assess the
overall alien crosstalk from all other ports. This test procedure is generally applicable to any
electrical connector, and is particularly suitable to connectors described in IEC 60603-7 series,
IEC 61076-3-104, and other types of connectors for data transmission.
2 Normative references
The following referenced documents are indispensable for the application of this document. For
dated references, only the edition cited applies. For undated references, the latest edition of
the referenced document (including any amendments) applies.
IEC 60050-581, International Electrotechnical Vocabulary (IEV) – Chapter 581:
Electromechanical components for electronic equipment
IEC 60512-26-100, Connectors for electronic equipment – Tests and measurement –
Part 26-100: Measurement setup, test and reference arrangements and measurements for
connectors according to IEC 60603-7 (tests 26a to 26g)
IEC 60603-7-4:2005, Connectors for electronic equipment – Part 7-4: Detail specification for 8-
way, unshielded, free and fixed connectors, for data transmissions with frequencies up to
250 MHz
IEC 60603-7 (all parts), Connectors for electronic equipment – Part 7: Detail specifications for
8-way, (un)shielded, free and fixed connectors, for data transmissions
IEC 61076-3-104:2006, Connectors for electronic equipment – Part 3-104: Detail specification
for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to
1000 MHz
IEC 61156, Multicore and symmetrical pair/quad cable for digital communications
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 60050-581 apply as
well as the following.
3.1
alien (exogenous) crosstalk (AXT)
signal coupling from disturbing conductor pairs into a disturbed pair of another connector

– 6 – 60512-25-9 © IEC:2008
3.2
alien (exogenous) near-end crosstalk (ANEXT) loss
signal coupling from a near-end disturbing conductor pair into a disturbed pair of another
connector, measured at the near-end
3.3
alien (exogenous) far-end crosstalk (AFEXT) loss
signal coupling from a near-end disturbing conductor pair into a disturbed pair of another
connector, measured at the far-end
3.4
power sum alien (exogenous) near-end crosstalk (PSANEXT) loss
a computation of signal coupling from multiple near-end disturbing conductor pairs, in one or
more connectors, into a disturbed pair of another connector, measured at the near-end
3.5
power sum alien (exogenous) far-end crosstalk (PSAFEXT) loss
a computation of signal coupling from multiple near-end disturbing conductor pairs, in one or
more connectors, into a disturbed pair of another connector, measured at the far-end
4 Overview
4.1 Procedure
Alien crosstalk is a property that exists between connectors. It is affected by the properties of
the connectors themselves, as well as the arrangement of the connectors in their mounting
system, and the mounting systems themselves. Examples of mounting systems include
faceplates, mounting boxes, frame-mounted panels, frames containing multiple panels, etc.
Where necessary, connectors in other frame-mounted panels, etc., in close proximity shall be
included as disturbing connectors. Alien crosstalk of the connector should be tested for all
mounting systems in which the connector is intended to be mounted, or a sub-set thereof, as
defined by the detail specification. Manufacturers may define a worst case mounting system,
and test in either or both.
This procedure may also be applied to multi-port connector panels, in which case each port of
the panel shall be treated as a discrete connector.
The mounting systems shall be filled, at a minimum, with all connectors that are significant in
respect to the alien crosstalk of the disturbed connector. The number of connectors that need
to be tested is explained in 5.3 and Clause 7. As there are generally four conductor pairs in
each connector, and therefore 16 pair combinations for each port combination, consideration
should be given for a convenient method for testing those combinations, such as automatic
switching. Further, the interconnection method between the baluns and the CUT (connectors
under test) should provide sufficient flexibility to easily connect the baluns to different CUTs.
As the devices need to be terminated with cables, a minimum of two cables, each at least 40 m
long, shall be available, and for convenience consideration should be given to having a larger
number of termination cables available. These cables shall be separated as far as possible
during the test.
The procedure to perform this test shall be as follows. The mounting system for the connectors
shall be set up near the measurement system. The connectors shall be installed in the
mounting system. One connector shall be selected as the disturbed connector for a particular
instance of this test. Another connector shall be selected as the first disturbing connector. The
two connectors shall be terminated and connected to the measurement system as specified in
Clause 6. The ANEXT loss and AFEXT loss, as required, shall be measured, between these
connectors, as specified in Clause 6. The significance of the alien crosstalk, for each
frequency point of each pair combination, shall be checked, per Clause 7. A determination shall
be made, per Clause 7, whether additional disturbing connectors need to be tested for this
disturbed connector. Testing shall continue until all significant disturbing connectors have been

60512-25-9 © IEC:2008 – 7 –
tested, per 5.3 and Clause 7. Then, the power sum of all significant pair-to-pair measurements
shall be calculated, per Clause 9. Finally, a report shall be written per Clause 9. If required,
additional disturbed connectors, and additional mounting arrangements, may be tested.
The preceding paragraph provides the procedure by which all the necessary information shall
be obtained. The steps may be performed in any order.
Annex A illustrates the above.
4.2 Resources
The measurements shall be performed using a network analyzer, or with a signal generator
and receiver.
The required equipment includes:
a) A network analyzer with a minimum frequency range of 1 MHz to 1 GHz shall preferably be
used. A signal generator and a receiver may also be used.
b) If baluns are used, a minimum of 2 baluns meeting the requirements of
IEC 60603-7-4, Annex D, extrapolated to the highest frequency of interest (8 baluns are
recommended).
c) A minimum of 2 cables, minimum 40 m long, suitable for terminating all pairs of the far
ends of the connectors under test. These shall be minimum category 6, IEC 61156 cables.
For category 7 or better connectors, the terminating cables shall be the same or higher
category as the connectors. Their return loss and balance should be as good as possible,
to provide the best possible connector termination. Consideration should be given to the
use of a larger number of cables. Cables are needed for both the cable termination (fixed)
end, and the free (plug) end, of the connector;
NOTE It should be recognized that each time the cable is used to terminate one connector, it will shorten by
approximately 50 mm.
d) Two short "plugs", or cables, or "wiring harnesses", to connect from the baluns to the near
ends of the devices under test.
e) A means to provide 100 Ω differential, and 50 Ω common, mode terminations, on all unused
pairs of both ends of the connectors under test; discrete precision surface-mount resistors
are recommended.
f) At least one sample of each connector mounting system in which the connectors are to be
tested.
g) A sufficient number of samples of the connector to be tested. It is recommended to have
enough to completely fill the mounting system.
h) Coaxial cables to interconnect between the network analyzer and the baluns. It is
recommended to use high quality phase-stable cables.
i) It is recommended to have a convenient mounting system, to arrange the recommended 8
baluns into two groups of four.
j) It is recommended to have an automatic switching system to change among the 16 pair
combinations.
5 Overall test arrangement
5.1 General
It is recommended to use eight baluns, arranged in two clusters of four, and to minimize the
separation of the baluns within each balun cluster. In this case, it is advantageous to use a
multi-port (minimum 8 ports) coaxial switch, to automate testing. The schematic for the use of
such a switch is shown in Annex B. Figure 1 shows a schematic for testing without a switch.

– 8 – 60512-25-9 © IEC:2008
40 m cable
termination
Balun
NA
40 m cable
termination
Balun
IEC  1457/08
Key
NA Network analyzer
Figure 1 – Schematic for testing without a switch
5.2 Terminations
For measurement (noise) floor measurements, and for all ANEXT and AFEXT measurements,
both ends of all pairs of both connectors under test shall be terminated with common and
differential mode terminations per IEC 60603-7-4, Clause D.6 or per 3.4 of IEC 60512-26-100.
The pair ends under test shall be terminated through the baluns, with a 50 Ω coaxial cable on
the differential input, and a 50 Ω termination resistor on the centre tap. Unused pairs on these
ends may be terminated either with baluns and terminating resistors, or with precision resistor
networks. Screens and/or shields, if present, shall also be connected to this same node. The
termination cables shall be separated as far as possible during the test.

Termination schematic
for
AXT measurements
To shield To shield
IEC  1458/08
Figure 2 – Schematic for terminations
5.3 Pairs of connectors to test
At a minimum, all connectors adjacent to the disturbed connector, in all directions including
diagonal directions, shall be tested in combination with that connector. Figure 3 illustrates an
array. If any disturbing connector is deemed "significant" per Clause 7, then the next further
away connector in the same direction from the disturbed connector shall also be tested.

60512-25-9 © IEC:2008 – 9 –
Testing of disturbing connectors in this direction from the disturbed connector shall continue,
until a connector is tested which is not "significant". At this point, no further connectors in this
direction away from the disturbed connector need to be tested.
X
IEC  1459/08
Figure 3 – Connector array
Notes to Figure 3
NOTE 1 If the mounting hardware is smaller than this array, those positions which are not present are ignored.
However, the influences of other mounting systems in close proximity of the system under test shall
be taken into account.
NOTE 2 In this example, when the disturbed connector "X" is tested, alien crosstalk into it from connectors A,
B, C, D, E, F, G, and H, shall be tested. In the event that connector B contributes significant alien
crosstalk, the alien crosstalk from connector BB into connector X shall also be tested. In the event
that connector BB also contributes significant alien crosstalk, the alien crosstalk from connector BBB
(not labelled) into connector X shall also be tested, etc.
NOTE 3 In this example, if either connector F or connector CC contributes significant alien crosstalk into
connector X, the alien crosstalk from connector J into connector X shall also be tested.
NOTE 4 Although rectangular connectors are illustrated in this example, the same principle can be applied to
connectors which are round, square, trapezoidal, or otherwise shaped.
NOTE 5 This is an example for illustration purposes; mounting hardware used is not required to conform to
this illustration.
If required, other connectors in the mounting system may also be tested as the disturbed
connector. It is suggested that, at a minimum, at least one connector in the most vulnerable
position, such as the middle, be tested.
When the connector to be tested is a ganged connector, such as a multi-port patch panel,
special considerations apply. The cable (rear) side of the panel should be inspected, and
connector ports which may not be near the disturbed connector on the front side, but are near
on the back, should be tested. Consideration should be given to testing at least two ports on
each side of the disturbed port. Consideration should be given to testing all port combinations
in the gang, as there may be internal circuit paths in close proximity.

– 10 – 60512-25-9 © IEC:2008
6 Procedure to test alien crosstalk from one connector to another connector
6.1 Calibration
A minimum of 100 frequency points per decade shall be tested, and a linear frequency sweep
shall be used.
For each of the 16 pair combinations between connectors, perform a 2-port calibration. It is
recommended to use a zero-length through calibration, with the baluns back-to-back, however
it is acceptable to use a short twisted-pair jumper as the through. It is recommended to omit
the isolation calibration step. Short, load, and open calibration artefacts shall be placed at the
balun output. Other calibration requirements of E.4.1 of IEC 60603-7-4 shall be followed.
6.2 Measurement (noise) floor
Two termination cables shall be connected directly to the two baluns or balun clusters. The
cables shall be separated by at least 25 mm throughout their length. The far ends of the cables
shall be terminated according to Clause 5 above. The ANEXT between them shall be
measured. It is recommended that the noise floor be at least 100 dB throughout the frequency
range.
6.3 Alien crosstalk measurement
Unless otherwise specified in the detail specification, the alien crosstalk shall be measured in
both directions. To measure ANEXT in the "forward" direction 2 four-pair test cables, or "plugs"
shall be used. These are to be, preferably, a short length, approximately 80 mm, and shall not
be longer than 300 mm. The "front" end of these plugs shall be connected to the baluns. The
four pairs shall be fanned out orthogonally, over as short a distance as possible, to connect to
the baluns. This distance should be minimized, to avoid common mode return loss effects. It is
recommended to manage the common mode impedance of the pairs by placing them in the
vicinity of a ground plane, or by some other method. The far ends of the two connectors shall
be terminated to four-pair terminating cables which are at least 40 m long. The far ends of
those cables shall be terminated according to Clause 5 above. Adequate separation between
the two terminating cables shall be maintained, also between the two test-cables, as cable-to-
cable alien crosstalk will affect the test result.

60512-25-9 © IEC:2008 – 11 –
Test directions diagram
for
AXT measurements
Forward ANEXT
Reverse ANEXT
Socket Socket
Plug Transmit Plug
Transmit
Socket
Socket
Plug Receive
Receive Plug
Forward AFEXT
Reverse AFEXT
Socket Socket
Plug Transmit Transmit Plug
Socket Socket
Receive Plug Plug Receive
IEC  1460/08
Figure 4 – Test directions
To measure ANEXT in the "reverse" direction, the non-plug end of the connector shall be
connected to the baluns using a short (approximately 80 mm) test cable, balun interface as
described above. A plug shall be mounted on the near end of the termination cable, its far end
shall be terminated as in Clause 5 above; the plug and connector shall be mated.
To measure AFEXT in the "forward" direction, the disturbing connector shall be terminated as
for ANEXT in the forward direction above, and the disturbed connector as in the reverse
direction above. The disturbing signal shall be launched into the free end (plug end) of the
disturbing connector, and the alien crosstalk shall be monitored at the cable end of the
disturbed connector.
To measure AFEXT in the "reverse" direction, the disturbed connector shall be terminated as
for ANEXT in the forward direction above, and the disturbing as in the reverse direction above.
The disturbing signal shall be launched into the cable end of the disturbing connector, and the
alien crosstalk will be monitored at the free end of the disturbed connector.
7 Procedure for determining significance
The pair-to-pair alien crosstalk trace shall be plotted and compared with the significance limit.
The significance limit, unless otherwise specified in the detail specification, shall be 20 dB
better than the requirement, or 90 dB, whichever is less.
If at any frequency point on any pair combination, the pair-to-pair alien crosstalk exceeds the
significance limit, this disturbing connector shall be deemed "significant" to the disturbed
connector.
If this disturbing connector is deemed significant, then all data at frequency points and pair
combinations that exceed the limit shall be included in the power sum calculations described in

– 12 – 60512-25-9 © IEC:2008
Clause 9. All data that is less than the significance limit shall be discarded. Testing shall
continue per 5.3.
8 Details to be specified in the detail specification
Whenever PSANEXT or PSAFEXT is required by the detail specification, the following shall be
specified in the detail specification:
a) the PSANEXT and PSAFEXT performance requirements;
b) the frequency range of interest, if different than 1 MHz to 1 000 MHz;
c) the significance limit, if different than in Clause 7 above;
d) it is recommended that the detail specification provides special mounting or terminating
instructions for a particular connector configuration for this test. In the absence of such
information, these details shall be per manufacturer’s instructions, or the discretion of the
test laboratory.
9 Power sum calculation, report and documentation
When all significant disturbing connectors have been tested and all insignificant data
discarded, the power sum calculation shall be made. Individual power sum calculations for
each pair in the disturbed connector shall be made for forward direction PSANEXT, reverse
direction PSANEXT, forward direction PSAFEXT, and reverse direction PSAFEXT.
As an example, for each pair of the disturbed connector,
PSANEXT = –10*lg(sum(10^(–ANEXT(n,m)/10)) dB, where
th
ANEXT(n,m) is the pair-to-pair ANEXT loss from pair n (n=1 to 4) of the m significant
disturbing connector, into the given pair of the disturbed connector.
A report shall be prepared which shall include:
a) preferably a graph of the PSANEXT (and/or PSAFEXT) of all four pairs, preferably in both
directions, for each disturbed connector tested; alternatively, a table of values is
acceptable. The x-axis shall be frequency and the y-axis shall be alien crosstalk;
NOTE This test method is not limited to 8 ways (four pairs) connectors.
b) the lowest margin to the specification at any frequency point on any pair;
c) a description of the connector tested and the mounting hardware used and cable
termination details;
d) which positions in the mounting hardware were used for the disturbed connector;
e) the centreline pitches between connectors;
f) out-of-plane displacement of connectors, if there is any.

60512-25-9 © IEC:2008 – 13 –
Annex A
(informative)
Flow chart for obtaining alien crosstalk performance data

Select
connector
Select
mounting
system
Obtain and assemble
sufficient samples
Select
Select
test direction
disturbed connector
e.g. forward, reverse
Select
List
st
near disturbers
disturber
Select
Select Measure
next
next new alien
disturber
disturber crosstalk
Yes
If
Add to list of
Yes
No
AXT > significance
More to measure
near disturbers
level
on list?
as needed
No
Select
Yes
Perform power
More test
next test
sum calculation
directions?
direction
No
Write
Yes No
Test additional
test
disturbed connector
report
IEC  1461/08
Figure A.1 – Flowchart for the test procedure

– 14 – 60512-25-9 © IEC:2008
Annex B
(informative)
Illustrations of alien crosstalk testing using coaxial switching

Balun
Balun
Balun
40 m cable
termination
Balun
8 port
NA
coaxial
switch 40 m cable
termination
Balun
Balun
Balun
IEC  1462/08
Balun
Key
NA Network analyzer
Figure B.1 – Schematic for testing with a switch

60512-25-9 © IEC:2008 – 15 –
IEC  1463/08
Figure B.2 – Example network analyzer, switch, and fixture with 8 baluns in 2 clusters
All photographs are for illustrative purposes only there is no requirement to use any specific
brand of equipment.
– 16 – 60512-25-9 © IEC:2008
It is recommended to mount each balun cluster in such a way as to provide freedom to move
them to adapt to slightly different connector spacing and orientation that may be present
among different connector pairs in the mounting system.
IEC  1464/08
Figure B.3 – Example of fixture, in which balun clusters can slide left and right

60512-25-9 © IEC:2008 – 17 –
IEC  1465/08
Figure B.4 – Post can rotate three different directions

– 18 – 60512-25-9 © IEC:2008
Bibliography
IEC 60068-1:1988, Environmental testing – Part 1: General and guidance
IEC 61196-1:2005, Coaxial communication cables – Part 1: Generic specification – General,
definitions and requirements
ISO/IEC 11801 Ed.2: Information technology – Generic cabling for customer premises

___________
– 20 – 60512-25-9 © CEI:2008
SOMMAIRE
AVANT-PROPOS .21
1 Domaine d'application et objet .23
2 Références normatives .23
3 Termes et définitions .23
4 Vue d’ensemble .24
4.1 Mode opératoire .24
4.2 Ressources .25
5 Disposition d’essai globale.26
5.1 Généralités.26
5.2 Sorties.26
5.3 Paires de connecteurs en vue de l’essai .27
6 Procédure en vue de soumettre à l’essai la diaphonie exogène d’un connecteur à
un autre.28
6.1 Etalonnage .28
6.2 Plancher (de bruit) de mesure.28
6.3 Mesure de la diaphonie exogène.28
7 Procédure pour la détermination de la signification.30
8 Détails à spécifier dans la spécification particulière .30
9 Calcul de la somme des puissances, rapport et documentation .30
Annexe A (informative) Logigramme pour l’obtention des données de performance de
diaphonie exogène .32
Annexe B (informative) Illustrations de l’essai de diaphonie exogène utilisant la
commutation coaxiale.33
Bibliographie
Figure 1 – Schéma d’essai sans interrupteur .26
Figure 2 – Schéma pour les sorties .27
Figure 3 – Disposition des connecteurs .27
Figure 4 – Directions d’essai .29
Figure A.1 – Logigramme pour la procédure d’essai .32
Figure B.1 – Schéma d’essai avec un interrupteur .33
Figure B.2 – Exemple d’analyseur de réseau, interrupteur et dispositifs avec 8
symétriseurs en 2 groupes .34
Figure B.3 – Exemple de dispositif, dans lequel les groupes de symétriseurs peuvent
glisser de gauche à droite .35
Figure B.4 – Le dispositif peut effectuer une rotation dans trois sens différents.36

60512-25-9 © CEI:2008 – 21 –
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
CONNECTEURS POUR ÉQUIPEMENTS ÉLECTRONIQUES –
ESSAIS ET MESURES –
Partie 25-9: Essais d'intégrité des signaux –
Essai 25i: Diaphonie exogène
AVANT-PROPOS
1) La CEI (Commission Electrotechnique Internationale) est une organisation mondiale de normalisation composée
de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a pour objet de
favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de
l'électricité et de l'électronique. A cet effet, la CEI – entre autres activités – publie des Normes internationales,
des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au public (PAS) et des
Guides (ci-après dénommés "Publication(s) de la CEI"). Leur élaboration est confiée à des comités d'études,
aux travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les organisations
internationales, gouvernementales et non gouvernementales, en liaison avec la CEI, participent également aux
travaux. La CEI collabore étroitement avec l'Organisation Internationale de Normalisation (ISO), selon des
conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux de la CEI
intéressés sont représentés dans chaque comité d’études.
3) Les Publications de la CEI se présentent sous la forme de recommandations internationales et sont agréées
comme telles par les Comités nationaux de la CEI. Tous les efforts raisonnables sont entrepris afin que la CEI
s'assure de l'exactitude du contenu technique de ses publications; la CEI ne peut pas être tenue responsable de
l'éventuelle mauvaise utilisation ou interprétation qui en est faite par un quelconque utilisateur final.
4) Dans le but d'encourager l'unification internationale, les Comités nationaux de la CEI s'engagent à appliquer de
façon transparente, dans toute la mesure possible, les normes internationales de la CEI dans leurs normes
nationales et régionales. Toutes divergences entre toutes Publications de la CEI et toutes publications
nationales ou régionales correspondantes doivent être indiquées en termes clairs dans ces dernières.
5) La CEI n’a prévu aucune procédure de marquage valant indication d’approbation et n’engage pas sa
responsabilité pour les équipements déclarés conformes à une de ses publications.
6) Tous les utilisateurs doivent s'assurer qu'ils sont en possession de la dernière édition de cette publication.
7) Aucune responsabilité ne doit être imputée à la CEI, à ses administrateurs, employés, auxiliaires ou
mandataires, y compris ses experts particuliers et les membres de ses comités d'études et des Comités
nationaux de la CEI, pour tout préjudice causé en cas de dommages corporels et matériels, ou de tout autre
dommage de quelque nature que ce soit, directe ou indirecte, ou pour supporter les coûts (y compris les frais
de justice) et les dépenses découlant de la publication ou de l'utilisation de cette Publication de la CEI ou de
toute autre Publication de la CEI, ou au crédit qui lui est accordé.
8) L'attention est attirée sur les références normatives citées dans cette publication. L'utilisation de publications
référencées est obligatoire pour une application correcte de la présente publication.
9) L’attention est attirée sur le fait que certains des éléments de la présente Publication de la CEI peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme internationale CEI 60512-25-9 a été établie par le sous-comité 48B: Connecteurs, du
comité d'études 48 de la CEI: Composants électromécaniques et structures mécaniques pour
équipements électroniques.
Le texte de cette norme est issu des documents suivants:
FDIS Rapport de vote
48B/1915/FDIS 48B/1930/RVD
Cette publication a été rédigée selon les Directives ISO/CEI, Partie 2.
...