CLC/TC 40XA - CLC/TC 40XA
To prepare European standards, which are required to facilitate the trading activities of European component users and manufacturers, in the following areas: a) capacitors, fixed and variable, for use in electronic equipment; b) capacitors, resistors and inductors, and combinations of these, used for electro-magnetic interference suppression, and complete electro-magnetic interference suppression filter units; c) networks and passive integrated circuits containing capacitors, or combinations of resistors, capacitors and inductors. Close liaison is maintained with IEC TC 40 which includes parallel voting enabling IEC documents to be adopted in Europe. Liaison is also maintained with relevant IEC Technical Committees, such as 47, 91, 104, and, in the area of safety, 61, 62 and 108, where such liaison will promote the convergence of the two systems. Note : This committee does not deal with - lighting capacitors, which are the responsibility of CLC/TC 34Z; - power capacitors and power filters, which are covered by TC 33 in IEC, and ratified under the parallel vote procedure in Europe.
CLC/TC 40XA
To prepare European standards, which are required to facilitate the trading activities of European component users and manufacturers, in the following areas: a) capacitors, fixed and variable, for use in electronic equipment; b) capacitors, resistors and inductors, and combinations of these, used for electro-magnetic interference suppression, and complete electro-magnetic interference suppression filter units; c) networks and passive integrated circuits containing capacitors, or combinations of resistors, capacitors and inductors. Close liaison is maintained with IEC TC 40 which includes parallel voting enabling IEC documents to be adopted in Europe. Liaison is also maintained with relevant IEC Technical Committees, such as 47, 91, 104, and, in the area of safety, 61, 62 and 108, where such liaison will promote the convergence of the two systems. Note : This committee does not deal with - lighting capacitors, which are the responsibility of CLC/TC 34Z; - power capacitors and power filters, which are covered by TC 33 in IEC, and ratified under the parallel vote procedure in Europe.
General Information
- Corrigendum7 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-9:2024 is available as IEC 60384-9:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60384-9:2024 is applicable to fixed capacitors of ceramic dielectric with a defined temperature coefficient (dielectric Class 2), intended for use in electronic equipment, including leadless capacitors but excluding fixed surface mount multilayer capacitors of ceramic dielectric, which are covered by IEC 60384-22 (Class 2). Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. The object of this document is to specify preferred ratings and characteristics and to select from IEC 60384-1:2021 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this document provide specific test severities and requirements of an equal or higher performance level. Further information on the conception of generic, sectional and detail specifications can be found in the Introduction of IEC 60384-1:2021. This edition includes the following significant technical changes with respect to the previous edition: a) The document has been completely restructured to comply with ISO/IEC Directives, Part 2 and to make it more useable; tables, figures and references have been revised accordingly. Annex X contains all cross-references of changes in clause/subclause numbers. b) The requirements of reference temperature 25 °C have been added in Table 7, Table 9, Table 11, Table 13 and Table 15. c) The table of temperature characteristics of capacitance for the reference temperature 25 °C have been added in Table B.1, Table B.2 and Table B.3. d) Annex B has been changed from informative to normative. e) Clause C.5 (Test schedule for quality conformance inspection) has been newly added to withdraw the blank detail specification: IEC 60384-9-1.
- Standard48 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-8:2024 is available as IEC 60384-8:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60384-8:2024 is applicable to fixed capacitors of ceramic dielectric with a defined temperature coefficient (dielectric Class 1), intended for use in electronic equipment, including leadless capacitors but excluding fixed surface mount multilayer capacitors of ceramic dielectric, which are covered by IEC 60384-21 (Class 1). Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. The object of this document is to specify preferred ratings and characteristics and to select from IEC 60384-1:2021, the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this document provide specific test severities and requirements of an equal or higher performance level. Further information on the conception of generic, sectional and detail specifications can be found in the Introduction of IEC 60384-1:2021. This edition includes the following significant technical changes with respect to the previous edition: a) The document has been completely restructured to comply with ISO/IEC Directives, Part 2 and to make it more useable; tables, figures and references have been revised accordingly. Annex X contains all cross-references of changes in clause/subclause numbers. b) The terms have been replaced by the letter symbols in Table 3. c) Code of temperature coefficient and tolerance of C0G, U2J have been added in Table 4, Table 6, Table 8, Table 9, Table 11, Table 13, Table 16 and Annex B. d) Annex B has been changed from informative to normative. e) Clause C.5 (Test schedule for quality conformance inspection) has been newly added to withdraw the blank detail specification: IEC 60384-8-1.
- Standard55 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-21:2024 is applicable to fixed unencapsulated surface mount multilayer capacitors of ceramic dielectric with a defined temperature coefficient (dielectric Class 1), intended for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted on printed boards, or directly onto substrates for hybrid circuits. Capacitors for electromagnetic interference suppression are not included but are covered by IEC 60384-14. The object of this document is to specify preferred ratings and characteristics and to select from IEC 60384-1:2021 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this sectional specification provide specific test severities and requirements of an equal or higher performance level. Further information on the conception of generic, sectional and detail specifications can be found in the Introduction of IEC 60384-1:2021. This edition includes the following significant technical changes with respect to the previous edition: a) the document has been completely restructured to comply with the ISO/IEC Directives, Part 2 and to make it more useable; tables, figures and references have been revised accordingly; Annex X contains all cross-references of changes in clause/subclause numbers; b) the terms have been replaced by the letter symbols in Table 3; c) code of temperature coefficient and tolerance of C0G, U2J have been added in Table 4, Table 6, Table 8, Table 9, Table 11, Table 13, Table 16 and Annex B; d) the requirement in 5.5.2(visual examination) has been repeated in 5.9.3, 5.10.5, 5.11.4, 5.11.4, 5.13.7, 5.14.5 and 5.15.5; e) the deflection D in the very robust designs has been added in 5.9.1; f) Annex B has been changed informative into normative; g) Clause C.5 (Test schedule for quality conformance inspection) has been newly added to withdraw the blank detail specification: IEC 60384-21-1.
- Standard48 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-22:2024 is applicable to fixed unencapsulated surface mount multilayer capacitors of ceramic dielectric, Class 2, for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted on printed boards, or directly onto substrates for hybrid circuits. Capacitors for electromagnetic interference suppression are not included but are covered by IEC 60384-14. The object of this document is to specify preferred ratings and characteristics and to select from IEC 60384-1:2021 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this sectional specification provide specific test severities and requirements of an equal or higher performance level. Further information on the conception of generic, sectional and detail specifications can be found in the Introduction of IEC 60384-1:2021. This edition includes the following significant technical changes with respect to the previous edition: a) The document has been completely restructured to comply with the ISO/IEC Directives, Part 2 and to make it more useable; tables, figures and references have been revised accordingly. b) The requirements of reference temperature 25 °C has been added in Table 5, Table 9, Table 10, Table 12, Table 14 and Table 17. c) The table of temperature characteristics of capacitance for the reference temperature 25 °C have been added in Table C.1, Table C.2 and Table C.3. d) The requirement in 5.5.2 (visual examination) has been repeated in 5.9.3, 5.10.6, 5.11.4, 5.12.6, 5.13.8, 5.14.6 and 5.15.6. e) The deflection D in the very robust designs has been added in 5.9.1. f) Annex C has been changed informative into normative. g) Clause D.5 (Test schedule for quality conformance inspection) has been newly added to withdraw the blank detail specification: IEC 60384-22-1.
- Standard55 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60939-3:2024 is available as IEC 60939-3:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60939-3:2024 covers passive filters used to attenuate unwanted radio-frequency signals (such as noise or interference) generated from electromagnetic sources. Both single and multi-channel filters within one enclosure or which are built on a printed circuit board forming a compact entity are included within the scope of this document. This document applies to passive filter units for electromagnetic interference suppression for which safety tests are appropriate. This implies that filters specified according to this document will either be connected to mains supplies, when compliance with the mandatory tests of Table B.1 is necessary, or used in other circuit positions where the equipment specification specifies that some or all of these safety tests are required. This document applies to passive filter units, which will be connected to an AC mains or other supply (DC or AC) with a nominal voltage not exceeding 1 000 V AC, with a nominal frequency not exceeding 400 Hz, or 1 500 V DC. Note: For AC use, IEC 60384-14 applies to capacitors which will be connected to AC mains with a nominal frequency not exceeding 100 Hz. This document covers appliance filters (US) but does not cover facility filters, cord-connected filters or direct plug-in filters. These other filters will be covered by another sectional specification. This edition includes the following significant technical changes with respect to the previous edition: a) separated clauses for safety and performance tests; b) added note for use of multiple X capacitors bridging basic insulation in 3 phase filters; c) characteristics and conditions to substitute X and Y capacitors are now described in a separate Subclause 4.1; d) creepage and clearance tables updated and in line with the latest editions of IEC 60938-2 and IEC 60664-1; e) allowing voltage measurement for inductance measurements (7.3); f) added requirements for marking depending on remaining energy after disconnection; g) added content of CTL DSH 2044:2016 for temperature test of IEC filters; h) added note about temperature rise required specimens for safety testing; i) changed index of capacitors in Annex A to avoid confusion between index name and capacitor class; j) moved tests from group 1A to 2. Now, samples in group 1A need to be submitted without potting; k) revision of all parts of the document has taken place based on the ISO/IEC Directives, Part 2:2021, and harmonization with other similar kinds of documents. Annex X contains all cross-references of changes in clause/subclause numbers.
- Standard84 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60938-2-1:2023 is applicable to the drafting of detail specifications for fixed inductors for which safety tests are required for use in electronic equipment. A blank detail specification is a supplementary document to the sectional specification and contains requirements for style, layout and minimum content of detail specifications. Detail specifications not complying with these requirements shall not be considered as being in accordance with IEC specifications nor shall they so be described. This edition includes the following significant technical changes with respect to the previous edition: a) it combines IEC 60938-2-1:1999 and IEC 60938-2-2:1999 into one Blank detail specification (BDS); b) test schedule for quality conformance inspection is moved to an informative annex (Annex B).
- Standard20 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment9 pagesEnglish languagesale 10% offe-Library read for1 day
- Corrigendum3 pagesEnglish and French languagesale 10% offe-Library read for1 day
IEC 60384-20:2023 is available as IEC 60384-20:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60384-20:2023 is applicable to fixed surface mount capacitors for direct current, with metallized electrodes and polyphenylene sulfide dielectric for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted directly onto printed boards or onto substrates for hybrid circuits. These capacitors can have "self-healing properties" depending on conditions of use. They are primarily intended for applications where the AC component is small with respect to the rated voltage. This part of IEC 60384 specifies preferred ratings and characteristics and selects from IEC 60384-1:2021 the appropriate quality assessment procedures, tests and measuring methods, and gives general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this sectional specification are of an equal or higher performance level; lower performance levels are not permitted. Capacitors for electromagnetic interference suppression are not included but are covered by IEC 60384‑14. This edition includes the following significant technical changes with respect to the previous edition: - revision of all parts of the document based on the ISO/IEC Directives, Part 2:2021, and harmonization with other similar kinds of documents; - the document structure has been organized to follow new sectional specification structure decided in TC 40; - revised tables and Clause 5 so as to prevent duplications and contradictions; - in Clause 5.2 (Mounting), the Subclauses 5.2.1, 5.2.2 and 5.2.3 have been added; - in Subclause 5.5 (Shear test), the Subclauses 5.5.1 and 5.5.2 have been added; - in Subclause 5.14 (Component solvent resistance), the Subclauses 5.14.1 and 5.14.2 have been added. In Table 8 and Table A.2, test 5.14 has been moved before 5.7.5 (Final inspections and requirements) in Group 1A and in Subgroup C1; - in Subclause 5.15 (Solvent resistance of marking), the Subclauses 5.15.1 and 5.15.2 have been added; - tangent of loss angle measurement has been added to resistance to soldering heat test; - lot-by-lot and periodical inspection tables, including requirements, have been moved to Annex A; - revised Inspection Level (IL) of A1 subgroup.
- Standard39 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-23:2023 is available as IEC 60384-23:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60384-23:2023 is applicable to fixed surface mount capacitors for direct current, with metallized electrodes and polyethylene naphthalate dielectric for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted directly onto printed boards or onto substrates for hybrid circuits. These capacitors can have "self-healing properties" depending on conditions of use. They are primarily intended for applications where the AC component is small with respect to the rated voltage. This part of IEC 60384 specifies preferred ratings and characteristics, selects from IEC 60384‑1:2021 the appropriate quality assessment procedures, tests and measuring methods and gives general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this sectional specification are of an equal or higher performance level. Lower performance levels are not permitted. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384‑14. This edition includes the following significant technical changes with respect to the previous edition: - this edition includes the following significant technical changes with respect to the previous edition: revision of all parts of the document based on the ISO/IEC Directives, Part 2:2021, and harmonization with other similar kinds of documents; - the document structure has been organized to follow new sectional specification structure decided in TC 40; - revised tables and Clause 5 so as to prevent duplications and contradictions; - in Subclause 5.2 (Mounting), the Subclauses 5.2.1, 5.2.2 and 5.2.3 have been added; - in Subclause 5.5 (Shear test), the Subclauses 5.5.1 and 5.5.2 have been added; - in Subclause 5.14 (Component solvent resistance), the Subclauses 5.14.1 and 5.14.2 have been added. In Table 8 and Table A.2, test 5.14 has been moved before 5.7.5 (Final inspections and requirements) in Group 1A and in Subgroup C1; - in Subclause 5.15 (Solvent resistance of marking), the Subclauses 5.15.1 and 5.15.2 have been added; - tangent of loss angle measurement has been added to the resistance to soldering heat test; - lot-by-lot and periodical inspection tables including requirements have been moved to Annex A; - revised Inspection Level (IL) of A1 subgroup.
- Standard40 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-14:2023 applies to capacitors and resistor-capacitor combinations intended to be connected to AC mains or other supply with a nominal voltage not exceeding 1 000 V AC (RMS), and with a nominal frequency not exceeding 100 Hz. This document includes also additional specific conditions and requirements for the connection to DC supplies with a rated voltage not exceeding 1 500 V DC. The principal object of this part of IEC 60384 is to prescribe preferred ratings and characteristics and to select, from IEC 60384-1, the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification are of equal or higher performance level; lower performance levels are not permitted. This document also provides a schedule of safety tests to be used by national testing stations in countries where approval by such stations is required. The overvoltage categories in combination with the AC mains voltages for the capacitors classified in this document are to be taken from IEC 60664-1. This edition includes the following significant technical changes with respect to the previous edition:
in damp heat steady state test, all capacitor types are tested both with and without rated voltage; the number of test pieces has been increased;
tangent of loss angle is added In Group 0 tests, in safety tests only;
qualification approval based on safety and performance tests has been removed from the main text to a normative annex;
the range of rated voltages is given instead of exact rated voltage values;
normative annex for description of capacitor styles and of creepage/clearance distance measurement has been added;
the importance of mechanical failures (cracks) in component encapsulation as a safety feature is highlighted in handling instructions and requirements after all relevant tests.
- Standard91 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62391-1:2022 applies to fixed electric double-layer capacitors (hereafter referred to as capacitors) mainly used in DC circuits of electric and electronic equipment. This part of IEC 62391 establishes standard terms, inspection procedures and methods of test for use in sectional and detail specifications of electronic components for quality assessment or any other purpose. This edition includes the following significant technical changes with respect to the previous edition:
The document has been completely restructured to comply with the ISO/IEC Directives, Part 2; a new technical categorization of test methods has been introduced and the test methods have been reorganized according to these new categories; tables, figures and references have been revised accordingly.
Calculation formula of charging/discharging efficiency in Annex D were divided into two cases: "Calculation assuming full charge and discharge" and "Calculation assuming incomplete charging and discharging due to internal resistance".
- Standard65 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-16:2019 applies to fixed capacitors with metallized electrodes and polypropylene dielectric for use in electronic equipment. These capacitors can have "self-healing properties" depending on conditions of use. They are mainly intended for use with direct voltage. Capacitors for alternating voltage and pulse applications are not included, but are covered by IEC 60384-17. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. Capacitors for electrical shock hazard protection (covered by IEC 60065) and fluorescent lamp and motor capacitors are also excluded.
- Standard40 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-11:2019 is applicable to fixed direct current capacitors, for rated voltages not exceeding 6 300 V, using as dielectric a polyethylene-terephthalate film and electrodes of thin metal foils. For capacitors with rated voltages exceeding 1 000 V, additional tests and requirements may be specified in the detail specification. The capacitors covered by this document are intended for use in electronic equipment. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384‑14. The object of this document is to prescribe preferred ratings and characteristics and to select from IEC 60384-1:2016 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification are of an equal or higher performance level. Lower performance levels are not permitted. This edition includes the following significant technical changes with respect to the previous edition: a) revision of all parts of the document based on the ISO/IEC Directives, Part 2:2018, and harmonization with other similar kinds of documents; b) the document structure has been organized to follow new sectional specification structure decided in TC 40; c) revised tables and Clause 5 so as to prevent duplications and contradictions.
- Standard35 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-1-1:2022 establishes a generic template and specifies requirements to the content of detail specifications for capacitors within the IEC 60384-X series. This part of IEC 60384-1 is applicable to the drafting of detail specifications for fixed capacitors for use in electronic equipment.
- Standard24 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-19:2022 is applicable to fixed surface mount capacitors for direct current, with metallized electrodes and polyethylene-terephthalate dielectric for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted directly onto printed boards or onto substrates for hybrid circuits. These capacitors can have "self-healing properties" depending on conditions of use. They are primarily intended for applications where the AC component is small with respect to the rated voltage. This part of IEC 60384 specifies preferred ratings and characteristics, and selects from IEC 60384‑1:2021 the appropriate quality assessment procedures, tests and measuring methods, and gives general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this sectional specification are of an equal or higher performance level. Lower performance levels are not permitted. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384‑14. This edition includes the following significant technical changes with respect to the previous edition:
revision of all parts of the document based on the ISO/IEC Directives, Part 2:2021, and harmonization with other similar kinds of documents;
the document structure has been organized to follow new sectional specification structure decided in TC 40;
revised tables and Clause 5 to prevent duplications and contradictions;
in Clause 5.2 (Mounting), 5.2.1, 5.2.2 and 5.2.3 have been added;
in Clause 5.5 (Shear test), 5.5.1 and 5.5.2 have been added;
in Clause 5.14 (Component solvent resistance), 5.14.1 and 5.14.2 have been added. In Table 8 and Table A.2, test 5.14 has been moved before 5.7.5 Final inspections in Group 1A and in Subgroup C1;
in Clause 5.15 (Solvent resistance of marking), 5.15.1 and 5.15.2 have been added;
tangent of loss angle measurement has been added to resistance to soldering heat test;
lot-by-lot and periodical inspection tables including requirements have been moved to Annex A;
revised Inspection Level (IL) of A1 subgroup.
- Standard40 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-17:2019 is available as IEC 60384-17:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60384-17:2019 applies to fixed capacitors with metallized electrodes and polypropylene dielectric for use in electronic equipment. Capacitors that have mixed film and metallized electrodes are also within the scope of this standard. These capacitors may have "self-healing" properties depending on conditions of use. Capacitors covered by this specification are mainly intended for use with alternating voltage and/or for pulse applications. The maximum reactive power applicable is 10 000 var and the maximum peak voltage is 3 000 V. This edition includes the following significant technical changes with respect to the previous edition: a) all parts of the document have been revised based on the ISO/IEC Directives, Part 2:2016 (seventh edition) and harmonization between other similar kinds of documents; b) tables and Clause 4 have been revised so as to prevent duplications and contradictions; c) new damp heat steady-state robustness classes with test conditions have been added in text, in Clause 4 and in Annex A.
- Standard47 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-22:2019 is available as IEC 60384-22:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60384-22:2019 is applicable to fixed unencapsulated surface mount multilayer capacitors of ceramic dielectric, Class 2, for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted on printed boards, or directly onto substrates for hybrid circuits. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. The object of this document is to prescribe preferred ratings and characteristics and to select from IEC 60384-1 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification are of equal or higher performance levels, lower performance levels are not permitted. This edition includes the following significant technical changes with respect to the previous edition: - revision of the structure in accordance with ISO/IEC Directives, Part 2:2016 (seventh edition) to the extent practicable, and for harmonizing with IEC 60384-21; - deletion of the description on the permissible reactive power in 6.2.2 because it is not appropriate for the purposes of this document; - the dimensions of 0201M in Annex A have been added.
- Standard47 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-21:2019 is available as IEC 60384-21:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60384-21:2019 is applicable to fixed unencapsulated surface mount multilayer capacitors of ceramic dielectric, Class 1, for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted on printed boards, or directly onto substrates for hybrid circuits. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. The object of this document is to prescribe preferred ratings and characteristics and to select from IEC 60384-1 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification are of equal or higher performance levels; lower performance levels are not permitted. This edition includes the following significant technical changes with respect to the previous edition: - revision of the structure in accordance with ISO/IEC Directives, Part 2:2016 to the extent practicable, and for harmonizing with IEC 60384-22; - deletion of the description on the permissible reactive power in 6.2.2 because it is not appropriate for the purposes of this document; - the dimensions of 0201M in Annex A have been added.
- Standard44 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60384 applies to fixed aluminium electrolytic surface mount capacitors with conductive polymer solid electrolyte, primarily intended for DC applications for use in electronic equipment. Fixed aluminium electrolytic surface mount capacitors with solid (MnO2) are not included but are covered by IEC 60384-18. These capacitors are primarily intended for use in electronic equipment to be mounted directly on substrates for hybrid circuits or to printed boards. Capacitors for special-purpose applications may need additional requirements. The object of this document is to prescribe preferred ratings and characteristics and to select from IEC 60384-1:2016, the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification shall be of equal or higher performance level, because lower performance levels are not permitted.
- Standard35 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60384 applies to fixed tantalum electrolytic surface mount capacitors with conductive polymer solid electrolyte primarily intended for DC applications for use in electronic equipment. Fixed tantalum electrolytic surface mount capacitors with solid (MnO2) electrolyte are not included but are covered by IEC 60384-3. These capacitors are primarily intended for use in electronic equipment to be mounted directly on substrates for hybrid circuits or to printed boards. Capacitors for special-purpose applications may need additional requirements. The object of this document is to prescribe preferred ratings and characteristics and to select from IEC 60384-1:2016 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification shall be of equal or higher performance level, because lower performance levels are not permitted.
- Standard34 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60384 is a generic specification and is applicable to fixed capacitors for use in electronic equipment. It establishes standard terms, inspection procedures and methods of test for use in sectional and detail specifications of electronic components for quality assessment or any other purpose.
- Standard84 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60938 applies to fixed inductors designed for electromagnetic interference suppression, which will be connected to an AC mains or other supply with a nominal voltage not exceeding 1 000 V AC RMS or 1 500 V DC with a nominal frequency not exceeding 400 Hz. This sectional specification is restricted to fixed inductors for which safety tests are appropriate. This implies that inductors specified according to this specification will either be connected to mains supplies, when compliance with the mandatory tests of Annex A is necessary, or used in other circuit positions where the equipment specification prescribes that some or all of these safety tests are required. The object of this document is to prescribe standard requirements for safety tests, preferred ratings and characteristics, to select from IEC 60938-1 the appropriate methods of test and to give general performance requirements for suppression inductors.
- Standard39 pagesEnglish languagesale 10% offe-Library read for1 day
This International Standard applies to inductors designed for electromagnetic interference suppression intended for use within all kind of electric and electronic equipment. In this Generic Specification normative reference, terms and definitions are given. It also prescribes General requirements and the suitable test and measurement procedures for interference suppression inductors.
- Standard35 pagesEnglish languagesale 10% offe-Library read for1 day
NEW!IEC 60384-26:2018 is available as IEC 60384-26:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60384-26:2018 applies to fixed aluminium electrolytic capacitors with conductive polymer solid electrolyte primarily intended for d.c. applications for use in electronic equipment. Fixed aluminium electrolytic capacitors with solid (MnO2) electrolyte are covered by IEC 60384-4. Fixed aluminium electrolytic surface mount capacitors with conductive polymer solid electrolyte are covered by IEC 60384-25. The object of this document is to prescribe preferred ratings and characteristics and to select from IEC 60384-1, the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification shall be of equal or higher performance level, because lower performance levels are not permitted. This edition includes the following significant technical changes with respect to the previous edition: - revision of the structure in accordance with ISO/IEC Directives, Part 2:2016 to the extent practicable, and harmonization between other similar kinds of documents; - in addition, Clause 4 and all the tables have been reviewed in order to prevent duplications and contradictions.
- Standard34 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60384 applies to fixed capacitors for direct current, with metallized electrodes and polyethylene-terephthalate dielectric for use in electronic equipment. These capacitors have a possibility of "self-healing properties" depending on conditions of use. They are primarily intended for applications where the AC component is small with respect to the rated voltage. Two performance grades of capacitors are covered: grade 1 for long-life application and grade 2 for general application. Capacitors for electromagnetic interference suppression and surface mount fixed metallized polyethylene-terephthalate film dielectric DC capacitors are not included, but are covered by IEC 60384-14 and IEC 60384-19, respectively. The object of this document is to prescribe preferred ratings and characteristics and to select from IEC 60384-1 the appropriate quality assessment procedures, tests and measuring methods, and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification are of equal or higher performance level, because lower performance levels are not permitted.
- Standard35 pagesEnglish languagesale 10% offe-Library read for1 day
2021-01-15 - IEC Corrected Version.
- Corrigendum5 pagesEnglish languagesale 10% offe-Library read for1 day
2020-12-25 - IEC Corrected Version
- Corrigendum4 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-13:2020 specifies preferred ratings and characteristics, selects from IEC 60384-1:2016 the appropriate quality assessment procedures, tests and measuring methods, and gives general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this sectional specification are of an equal or higher performance level. Lower performance levels are not permitted. This part of IEC 60384 applies to fixed direct current capacitors, using as dielectric a polypropylene film with electrodes of thin metal foils. The capacitors covered by this document are intended for use in electronic equipment. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. This edition includes the following significant technical changes with respect to the previous edition: a) revision of all parts of the document based on the ISO/IEC Directives, Part 2:2018, and harmonization with other similar kinds of documents; b) the document structure has been organized to follow new sectional specification structure decided in TC 40; c) revised tables and Clause 5 so as to prevent duplications and contradictions.
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-15:2017(E) applies to through-hole/leaded polar and bipolar tantalum electrolyte capacitors with solid and non‑solid electrolyte for use in electronic equipment. It includes capacitors for long‑life applications and capacitors for general‑purpose applications. This document prescribes preferred ratings and characteristics and to select from IEC 60384‑1:2016 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. This edition includes the following significant technical changes with respect to the previous edition: a) Revision of the structure in accordance with ISO/IEC Directives, Part 2:2016 (seventh edition) to the extent practicable, and harmonization between other similar kinds of documents. b) In addition, Clause 4 and all the tables have been reviewed in order to prevent duplications and contradictions.
- Standard37 pagesEnglish languagesale 10% offe-Library read for1 day
TAN - // IEC Corrigendum
- Corrigendum3 pagesEnglish languagesale 10% offe-Library read for1 day
TAN - // IEC Corrigendum
- Corrigendum3 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-4:2016 applies to fixed aluminium electrolytic capacitors with solid (MnO2) and non-solid electrolyte primarily intended for d.c. applications for use in electronic equipment. It covers capacitors for long-life applications and capacitors for general-purpose applications. Capacitors for special-purpose applications may need additional requirements.
- Standard44 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-14:2013 applies to capacitors and resistor-capacitor combinations which will be connected to an a.c. mains or other supply with nominal voltage not exceeding 1 000 V a.c. (r.m.s.) or 1 000 V d.c. and with a nominal frequency not exceeding 100 Hz. This fourth edition cancels and replaces the third edition published in 2005. It constitutes a technical revision. All changes that have been agreed upon can be categorized as minor revisions.
- Amendment8 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62391-1:2015(E) is available as IEC 62391-1:2015 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 62391-1:2015(E) applies to fixed electric double-layer capacitors (hereafter referred to as capacitor(s)) mainly used in d.c. circuits of electric and electronic equipment. This part of IEC 62391 establishes standard terms, inspection procedures and methods of test for use in sectional and detail specifications of electronic components for quality assessment or any other purpose. This edition includes the following significant technical changes with respect to the previous edition: a) enhancement of the scope to include electric (high power) application; b) implementation of Annex Q, replacing Clause 3 in the first edition; c) in addition, minor revisions related to tables, figures and references.
- Corrigendum3 pagesEnglish and French languagesale 10% offe-Library read for1 day
IEC 60384-3:2006 applies to surface mount tantalum solid electrolyte capacitors. These capacitors are primarily intended to be mounted directly onto substrates for hybrid circuits or onto printed boards. The following two styles are considered: Style 1 - protected capacitors; Style 2 - unprotected capacitors. This third edition cancels and replaces the second edition published in 1989 and constitutes a minor revision related to tables, figures and references This bilingual version, published in 2008-06, corresponds to the English version.
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-18:2007 applies to fixed aluminium electrolytic surface mount capacitors with solid (MnO2) and non-solid electrolyte primarily intended for d.c. applications for use in electronic equipment. It prescribes preferred ratings and characteristics and to select from IEC 60384-1 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification should be of equal or higher performance level, because lower performance levels are not permitted. This second edition cancels and replaces the first edition published in 1993 and its Amendment 1 (1998). This edition constitutes a minor revision related to tables, figures and references.
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-14-2:2016 forms the basis for a uniform procedure for a common International Safety Mark. It implements the approval schedule for safety tests in IEC 60384-14:2013, 1.4.2, requires a declaration of design for parameters relevant to safety and indicates conformance tests to be conducted on every lot prior to its release and requalification tests depending on changes to the declared design. This edition includes the following significant technical changes with respect to the previous edition: - The permitted number of non-conforming items in Table 2 is always zero following the sectional specification IEC 60384-14:2013. This publication is to be read in conjunction with IEC 60384-1:2016.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-14-1:2016 is a blank detail specification. It is a supplementary document to the sectional specification and contains requirements for style, layout and minimum content of detail specifications. In the preparation of detail specifications the content of 1.4 of the sectional specification shall be taken into account. This edition includes the following significant technical changes with respect to the previous edition: The assessment level has been changed to DZ (zero acceptance). The contents is the same as in old IEC 60384-14-3 with editorial changes. IEC 60384-14-3 has been deleted.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62391-1:2015(E) is available as IEC 62391-1:2015 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 62391-1:2015(E) applies to fixed electric double-layer capacitors (hereafter referred to as capacitor(s)) mainly used in d.c. circuits of electric and electronic equipment. This part of IEC 62391 establishes standard terms, inspection procedures and methods of test for use in sectional and detail specifications of electronic components for quality assessment or any other purpose. This edition includes the following significant technical changes with respect to the previous edition: a) enhancement of the scope to include electric (high power) application; b) implementation of Annex Q, replacing Clause 3 in the first edition; c) in addition, minor revisions related to tables, figures and references.
- Standard61 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60939-3:2015 covers passive filters used to attenuate unwanted radio-frequency signals (such as noise or interference) generated from electromagnetic sources. Both single and multi-channel filters within one enclosure or which are built on a printed circuit board forming a compact entity are included within the scope of this specification. This specification applies to passive filter units for electromagnetic interference suppression for which safety tests are appropriate. This implies that filters specified according to this specification will either be connected to mains supplies, when compliance with the mandatory tests of Table 3 is necessary, or used in other circuit positions where the equipment specification prescribes that some or all of these safety tests are required. This specification applies to passive filter units, which will be connected to an a.c. mains or other supply (d.c. or a.c.) with a nominal voltage not exceeding 1 000 V a.c., with a nominal frequency not exceeding 400 Hz, or 1 500 V d.c.
- Standard78 pagesEnglish languagesale 10% offe-Library read for1 day
IEC - Corrected version
- Corrigendum3 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-20:2015 applies to fixed surface mount capacitors for direct current, with metallized electrodes and polyphenylene sulfide dielectric for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted directly onto substrates for hybrid circuits or onto printed boards. They may have "self healing properties" depending on conditions of use and are primarily intended for applications where the a.c. component is small with respect to the rated voltage. This edition includes the following significant technical changes with respect to the previous edition: a) Revision of the structure in accordance with ISO/IEC Directives, Part 2:2011 (sixth edition) to the extent practicable, and harmonization between other similar kinds of documents. b) In addition, Clause 4 and all the tables have been reviewed in order to prevent duplications and contradictions.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-23:2015 is applicable to fixed surface mount capacitors for direct current, with metallized electrodes and polyethylene naphthalate dielectric for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted directly onto substrates for hybrid circuits or onto printed boards. These capacitors may have "self healing properties" depending on conditions of use. They are primarily intended for applications where the a.c. component is small with respect to the rated voltage. This edition includes the following significant technical changes with respect to the previous edition: a) Revised all parts of the document based on the ISO/IEC Directives, Part 2:2011 (sixth edition) and harmonization between other similar kinds of documents. b) Revised tables and Clause 4 so as to prevent duplications and contradictions.
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60384-19:2015 is applicable to fixed surface mount capacitors for direct current, with metallized electrodes and polyethylene-terephthalate dielectric for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted directly onto substrates for hybrid circuits or onto printed boards. These capacitors may have "self-healing properties" depending on conditions of use. They are primarily intended for applications where the a.c. component is small with respect to the rated voltage. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384 14. This edition includes the following significant technical changes with respect to the previous edition: a) Revised all parts of the document based on the IEC Directives Part 2:2011 (sixth edition) to the extent practicable, and harmonization between other similar kind of documents. b) Revised tables and Clause 4 so as to prevent duplications and contradictions.
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60940:2015 provides guidance applicable to information on application of capacitors, resistors, inductors, and complete filter units for electromagnetic interference suppression. This second edition cancels and replaces the first edition published in 1988. This second edition is a result of maintenance activities related to the previous edition. All changes that have been agreed upon can be categorized as minor revisions.
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62813:2015 specifies the electrical characteristics (capacitance, internal resistance, discharge accumulated electric energy, and voltage maintenance rate) test methods of lithium ion capacitors (LIC) for use in electric and electronic equipment.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
- Corrigendum3 pagesEnglish and French languagesale 10% offe-Library read for1 day
- Corrigendum4 pagesEnglish languagesale 10% offe-Library read for1 day