describes the injection clamp test method which determines the screening attenuation (as) of coaxial cables and the coupling attenuation (ac) of balanced shielded or unshielded data cables in a frequency range from 30 MHz up to 1 000 MHz and in a dynamic range up to 130 dB.

  • Standard
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Describes the test which determines the regularity of impedance of r.f. cables by measuring the return loss in the frequency domain using a vector network analyser equipped with a reflection test set (bridge) and transferring the results into the time domain by using the Inverse Discrete Fourier Transformation (IDFT).

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Relates to semi-rigid coaxial cable assemblies operating in the transverse electromagnetic mode (TEM). Establishes uniform requirements for testing the electrical, mechanical and environmental properties of semi-rigid coaxial cable assemblies composed of semi-rigid coaxial cables and coaxial connectors.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Relates to the subfamily of coaxial cables and connector assemblies operating int he frequency range of GSM (0,8 GHz - 1 GHz). Gives subfamily requirements and severities to be applied. Should be used together with EN 60966-3 and EN 600966-1.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Supplementary document ot the sectional specification and contains requirements for style and layout and minimum content of detail specifications.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Supplementary document to the sectional specification and contains requirements for style and layout and minimum content of detail specification. Should be used along with EN 60966-1 and EN 60966-2-1.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard relates to EN 50117 1 and should be read in conjunction with this generic specification. This standard applies to single and/or multiple miniaturised coaxial cables used in digital communication systems on the Telecom applications. The cables covered by this standard are used for the internal wiring of and interconnection between switching-, transmission-, multiplexing- and cross-connect equipment and for the connections to the digital distribution frame. These coaxial cables are designed for the transmission of E1 (2 Mbit/s), E2 (8 Mbit/s), E3 (34 Mbit/s), E4 (140 Mbit/s), STM (155 Mbit/s), DS1 (1,5 Mbit/s), DS2 (6 Mbit/s) and DS3 (34 Mbit/s) signals. Cables are connected to the equipment via a coaxial connector or other suitable ways. The purpose of this standard is to specify the applicable test methods and requirements for the electrical, mechanical, environmental and fire performance of the cables. The cables covered by this standard are intended to be used with voltages up to 50 V a.c. and/or 120 V d.c.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Prescribes recommended ratings and characteristics and selects from the generic specification the appropriate quality assessment procedures, test and measuring methods, and gives general performance requirements for coaxial cables for local area networks plus complementary test methods. Test severities and requirements prescribed in detail specifications referring to this sectional specification should be of equal or higher performance levels. When the requirements of IEC 61196-1 and of this sectional specification conflict with each other, this sectional specification shall prevail.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Relates to the subfamily of coaxial cables for digital communication. Should be used together with EN 61196-1 and EN 61196-3. Gives subfamily requirements and severities to be applied.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Relates to the subfamily of coaxial cables for digital communication. Should be used together with EN 61196-1 and EN 61196-3. Gives subfamily requirements and severities to be applied.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Gives general requirements for general purpose rigid coaxial transmission lines and their associated flange connectors in order to ensure compatibility and interchangeability, gives the tolerances necessary to ensure adequate electrical performance and the test methods.

  • Standardization document
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard describes three methods to determine the UV resistance of sheath materials for electric and for optical fibre cables. These tests apply for outdoor and indoor cable applications according to the product standard. The samples of sheath are taken from the finished cables. NOTE Although this test method standard is written principally for communication cables, it may be used for energy cables if called up by the relevant product standard. Methods differ by the nature of the UV source.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This sectional specification relates to EN 50117-1: Generic specification for coaxial cables, and is to be read in conjunction with this generic standard. This specification applies to coaxial cables for BCT-cabling in accordance with EN 50173 operating at a maximum d.c. voltage of 72 V and a maximum d.c. current of 0,5 A at a temperature range between –20 °C and +60 °C 1) and at frequencies between 5 MHz and 3 000 MHz and complying with the requirements of EN 50083. The purpose of this European Standard is to specify the applicable test methods and requirements for the electrical, mechanical, and environmental and fire performance of the cables.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Covers coaxial cables for use in analogue and digital systems. This standard should be used in conjunction with EN 50290-1-1. Coaxial cables covered by this standard in transverse electromagnetic (TEM) and are suitable for use in a wide range of digital and analogue applications including CATV, radio frequency systems, instrumentation, broadcasting, telecommunications and data network systems. Various constructions and materials for indoor and outdoor applications, including underground and overhead installations, and other environmental protection characteristics.

  • Amendment
    3 pages
    English language
    sale 10% off
    e-Library read for
    1 day

specifies reference measurement procedures for cabling parameters and the requirements for field tester accuracy to measure cabling parameters identified in ISO/IEC 11801. References in this standard to ISO/IEC 11801 mean ISO/IEC 11801 or equivalent cabling standards.

  • Standard
    78 pages
    English language
    sale 10% off
    e-Library read for
    1 day

provides methods to ensure the compatibility of modular plug cords to be used in cabling according to ISO/IEC 11801 and provides test methods and associated requirements to demonstrate the performance and reliability of these cords during their operational lifetime.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This sectional specification relates to EN 50117-1: Generic specification for coaxial cables, and should be read in conjunction with this generic standard. This specification applies to indoor drop cables for use in cabled distribution systems operating at temperature between –40 °C and +70 °C and at frequencies between 5 MHz and 1 000 MHz and complying with the requirements of EN 50083. The purpose of this European Standard is to specify the applicable test methods and requirements for the electrical, mechanical, environmental and fire performance of the cables.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard relates to EN 50117-1 and should be read in conjunction with this generic specification.This specification applies to indoor drop cables for use in cabled distribution systems operating at temperature between 40 °C and +70 °C 1) and at frequencies between 5 MHz and 3 000 MHz and complying with the requirements of EN 50083. The purpose of this European Standard is to specify the applicable test methods and requirements for the electrical, mechanical, environmental and fire performance of the cables.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard relates to EN 50117-1 and should be read in conjunction with this generic specification. This specification applies to distribution and trunk cables for use in cabled distribution systems operating at temperature between 40 °C and +70 °C 1) and at frequencies between 5 MHz and 1 000 MHz and complying with the requirements of EN 50083. The purpose of this European Standard is to specify the applicable test methods and requirements for the electrical, mechanical, environmental and fire performance of the cables.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard relates to EN 50117-1 and should be read in conjunction with this generic specification. This specification applies to outdoor drop cables for use in cabled distribution systems operating at temperature between 40 °C and +70 °C 1) and at frequencies between 5 MHz and 3 000 MHz and complying with the requirements of EN 50083. The purpose of this European Standard is to specify the applicable test methods and requirements for the electrical, mechanical, environmental and fire performance of the cables

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard relates to EN 50117-1 and should be read in conjunction with this generic specification. This specification applies to outdoor drop cables for use in cabled distribution systems operating at temperature between -40 °C and +70 °C 1) and at frequencies between 5 MHz and 1 000 MHz and complying with the requirements of EN 50083. The purpose of this European Standard is to specify the applicable test methods and requirements for the electrical, mechanical, environmental and fire performance of the cables.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Covers the requirements for flexible and semi-flexible radiating coaxial communication cables. It specifies preferred ratings and characteristics for radiating cables and enables selection of the appropriate tests and performance levels from the generic specification for inclusion in the detail specification.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Supplementary document to the sectional specification and contains requirements for style and layout and minimum content of detail specifications.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Relates to semi-flexible coaxial cable assemblies operating in the transverse electromagnetic mode (TEM). Establishes uniform requirements for testing the electrical, mechanical and environmental properties of semi-flexible coaxial cable assemblies composed of semi-flexible coaxial cables and coaxial connectors.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Relates to the subfamily of flexible coaxial cables and BNC connector assemblies. Gives subfamily requirements and severities to apply. Should be used together with EN 60966-2-1 and EN 60966-1.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Relates to flexible coaxial cable assemblies operating in the transverse electromagnetic mode (TEM). Establishes uniform requirements for testing the electrical, mechanical and climatic properties of flexible coaxial cable assemblies composed of flexible coaxial cables and coaxial connectors.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Prescribes recommended ratings and characteristics. Selects from the generic specification the appropriate quality assessment procedures, test and measuring methods. Gives general performance requirements for semi-rigid coaxial cables plus complementry test methods.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

is suitable to determine the surface transfer impedance and/or screening attenuation and coupling attenuation of mated screened connectors (including the connection between cable and connector) and cable assemblies. This method could also be extended to determine the transfer impedance, coupling or screening attenuation of balanced or multipin connectors and cable assemblies.

  • Standard
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Provides methods to ensure compatibility of modular plug cords to be used in cabling according to EN 50173 and also provides test methods and associated requirements to demonstrate the performance and reliability of these cords during their operational lifetime.

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to flexible coaxial cables described in EN 60096-2. It relates to cable assemblies for radio and TV receivers, and in particular to the cable subfamily 9,52

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to flexible coaxial cables described in EN 60096-2. It relates to cable assemblies for radio and TV receivers, and in particular to the cable subfamily 9,52

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Applies to flexible coaxial cables described in EN 60096-2. It relates to cable assemblies for radio and TV receivers, and in particular to the cable subfamily 9,52

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Gives rated characteristic impedances of coaxial, twin conductor and dual coaxial cables. Specifies standard diameters over dielectric for coaxial and flexible twin cables.

  • Standardization document
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard covers coaxial cables for use in analogue and digital systems. This standard should be used in conjunction with EN 50290 1 1. Coaxial cables covered by this standard operate in transverse electromagnetic mode (TEM) and are suitable for use in a wide range of digital and analogue applications including CATV, radio frequency systems, instrumentation, broadcasting, telecommunications and data network systems. Various constructions and materials provide for indoor and outdoor applications, including underground and overhead installations, and other environmental protection characteristics. Generally, cables are designed for use in 50 Ohm and 75 Ohm characteristic impedance systems, although other types (e.g. 93/95 Ohm) are also covered. Coaxial cables defined by this standard may be incorporated into hybrid cable constructions with optical fibre or multi-element cable components. All cables covered by this standard may be subjected to voltages greater than 50 V a.c. or 75 V d.c. However, these cables are not intended for direct connection to the mains electricity supply or other low impedance sources.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Supersedes EN 50117-2:1996 * Superseded by EN 50117-2-1:2005

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Withdrawn

  • Standardization document
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Specifies reference measurement procedures for cabling parameters and the requirements for field tester accuracy to measure cabling parameters identified in ISO/IEC 11801.

  • Standard
    65 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Describes the measurement of screening attenuation by the reverberation, or stirred, chamber, suitable for virtually any type of microwave component and having no theoretical upper frequency limit. It is only limited toward low frequencies due to the size of the test equipment, which is frequency dependent and is only one of several methods of measuring sreening attenuation. For the purpose of this standard, examples of microwave components are waveguides, phase shifters, diplexers/multiplexers, power dividers/combiners, etc.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN following parallel vote * Superseded by EN 61935-1:2005

  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Establishes uniform requirements for testing the electrical, mechanical and climatic properties of r.f. and coaxial cable assemblies composed of cables and connectors operating in the transverse electromagnetic mode (TEM). Tests are described in IEC 61196-1 and IEC 61169-1 respectively.

  • Standard
    59 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Relates to cable assemblies for radio and TV receivers, and in particular to the cable subfamily 9.52. Should be used together with EN 60966-1, 60966-2-1 and 60966-2-2.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Relates to the subfamily of coaxial cables and connector assemblies operating int he frequency range of GSM (0,8 GHz - 1 GHz). Gives subfamily requirements and severities to be applied. Should be used together with EN 60966-3 and EN 600966-1.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Relates to the subfamily of flexible coaxial cables and BNC connector assemblies. Gives subfamily requirements and severities to apply. Should be used together with EN 60966-2-1 and EN 60966-1.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Relates to cable assemblies for audio and TV receivers, and in particular to the cable subfamily 9.52.

  • Standard
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day